Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cybersecurity Requirements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Impact of Emergency Diesel Generator Reliability on Microgrids and Building-Tied Systems

Microgrids are an emerging alternative as an energy backup system for critical electric loads and have improved performance compared to the traditional architecture where a single emergency diesel generator is tied to an individual building. Both architectures are dependent on the reliability of their individual generators and a quantitative and realistic comparison of the overall system reliability of the two architectures is lacking. Using recently published work on emergency diesel generator finite reliability, a quantitative methodology is presented to compare the reliability of a microgrid architecture based on centralized emergency diesel generators to the traditional approach of generators tied to individual buildings. Three system reliability performance metrics are calculated as a function of outage duration: (1) probability to meet 100% of the critical load; (2) expected fraction of lost load; and (3) probability to meet the highest priority critical loads. It is shown that stand-alone building-tied emergency diesel generators systems, even when two emergency diesel generators are used per building, cannot provide the reliability required to sustain critical loads for a grid outage lasting multiple days. Due to their network configuration and ability to share load, diesel generator-based microgrid configurations are estimated to have = 93% probability of powering all buildings for a 2-week outage there the individual building-tied emergency diesel generator architecture has a =20% probability. Microgrids do present other susceptibilities that are site specific and should be considered including vulnerabilities associated with the on-campus distribution system and cybersecurity.

backup power↗

NASA Aeronautics Research Mission Directorate System Security Engineering Approaches

System security engineering (SSE) is a set of formal engineering methods and is considered a subset of systems engineering. It is a relatively new development in systems engineering with the initial NIST (National Institute of Standards) standard published in November of 2016 with updates in 2018, and 2022. The guiding principles in our methodology are based in NIST Special Publication 800-160 Vol. 1 “Systems Security Engineering: Considerations For A Multidisciplinary Approach In The Engineering Of Trustworthy Secure Systems” and integrate methodologies from common IT (Information Technology) threat modeling approaches utilizing MBSE (Model-Based Systems Engineering). The presentation will discuss how our teams utilize SSE and MBSE (Model-Based Systems Engineering) to develop secure architectures for systems under development in our NASA aeronautics research environment. This includes the activities to develop Protection Needs (PN) that, in turn result in security requirements in the design context and policies for the future state operational context for system protection. The process of applying SSE to analyze project architectures and ConOps (Concept of Operations) is intended to ensure the transferred research is both secure and securable in a “real-world” setting.

Systems Security Engineering↗

Adaptive Control Algorithm to Adjust Settings in Photovoltaic Inverters for Electric Grid Cybersecurity (DERAC) v0.1

Volt-VAR and Volt-Watt functionality in photovoltaic (PV) smart inverters provide mechanisms to ensure system voltage magnitudes and power factors remain within acceptable limits. However, these control functions can become unstable, introducing oscillations in system voltages when not appropriately configured or maliciously altered during a cyberattack. In the event that Volt-VAR and Volt-Watt control functions in a portion of PV smart inverters in a distribution grid are unstable, the proposed adaptation scheme utilizes the remaining and stably-behaving PV smart inverters and other Distributed Energy Resources to mitigate the effect of the instability in real-time. The adaptation mechanism is entirely decentralized, model-free, communication-free, and requires virtually no external configuration. This repository provides code to simulate the algorithm in experiments on the IEEE 37 node test feeder.

Arnold, Daniel↗

Electrification FY2020 Annual Progress Report

The Electric Drive Technologies (EDT) program’s mission is to conduct early-stage research and development on transportation electrification technologies that accelerate the development of cost-effective and compact electric traction drive systems that meet or exceed performance and reliability requirements of internal combustion engine (ICE)-based vehicles, thereby enabling electrification across all light-duty vehicle types.

33 ADVANCED PROPULSION SYSTEMS↗

Smart manufacturing maturity models and their applicability: a review

The purpose of this paper is to review existing smart manufacturing (SM) maturity models' dimensions and maturity levels to assess their applicability and drawbacks. There are many maturity models available but many of them have not been validated or do not provide a useful guide or tool for applications. This gap creates the need for a review of the existing maturity model's applicability. Nineteen peer-reviewed maturity models related to “Digital Transformation,” “Industry 4.0” or “Smart Manufacturing” were selected based on a systematic literature review and five consulting firm models were selected based on the author's industry knowledge. The chosen models were analyzed to determine 10 categories of dimensions. Then they are assessed on a 1–5 scale for how applicable they are in the 10 categories of dimensions. The five “consulting firm” models have a first-mover advantage, are more widely used in industry and are more applicable, but some require payment, and they lack published details and validation. The 19 “peer reviewed” models are not as widely used, lack awareness in the industry and are not as easy to apply because of no web tool for self-assessment, but they are improving. The categories defined to characterize the models and facilitate comparisons for users include “Information Technology (IT) and Cyber-Physical System (CPS) and Data,” “Strategy and Organization,” “Supply Chain and Logistics,” “Products and Services,” “Culture and Employees,” “Technology and Capabilities,” “Customer and Market,” “Cybersecurity and Risk,” “Leadership and Management” and “Governance and Compliance.” The analyzed maturity models were particularly weak in the areas of cybersecurity, leadership and governance. Researchers and practitioners can use this review with consideration of their specific needs to determine if a maturity model is applicable or if a new model needs to be developed. The review can also aid in the development of maturity models through the discussion of each of the dimension categories. Finally, compared to existing reviews of SM maturity models, this research determines comprehensive dimension categories and focuses on applicability and drawbacks.

42 ENGINEERING↗

Clean Energy Cybersecurity Accelerator: Cohort 2 - Asimily Public Report

The U.S. Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) sponsors the Clean Energy Cybersecurity Accelerator (TM) (CECA) to expedite the deployment of emerging security technologies that address the most urgent security concerns facing modern and future electric grids. CECA Cohort 2 assessed solutions focused on hidden risks due to incomplete system visibility and device security and configuration. Improving visibility can be achieved through operational technology (OT) asset identification solutions, including capabilities like automatic discovery, vulnerability reporting, and configuration monitoring. Solutions that monitor and identify assets in information technology (IT) networks in other domains are widely used; however, there is far less adoption of monitoring solutions for operational technology environments. Wider adoption may increase with increased confidence in the ability for these solutions to understand and respond to the specific requirements of OT environments. CECA Cohort 2 evaluated the active and passive asset discovery capabilities of market-ready solutions, documented and analyzed results, and identified gaps in functionality or capabilities. This report and describes how these results can help advance the adoption of these and similar solutions in the electric sector.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Testing convolutional neural network based deep learning systems: a statistical metamorphic approach

Machine learning technology spans many areas and today plays a significant role in addressing a wide range of problems in critical domains,i.e., healthcare, autonomous driving, finance, manufacturing, cybersecurity,etc. Metamorphic testing (MT) is considered a simple but very powerful approach in testing such computationally complex systems for which either an oracle is not available or is available but difficult to apply. Conventional metamorphic testing techniques have certain limitations in verifying deep learning-based models (i.e., convolutional neural networks (CNNs)) that have a stochastic nature (because of randomly initializing the network weights) in their training. In this article, we attempt to address this problem by using a statistical metamorphic testing (SMT) technique that does not require software testers to worry about fixing the random seeds (to get deterministic results) to verify the metamorphic relations (MRs). We propose seven MRs combined with different statistical methods to statistically verify whether the program under test adheres to the relation(s) specified in the MR(s). We further use mutation testing techniques to show the usefulness of the proposed approach in the healthcare space and test two CNN-based deep learning models (used for pneumonia detection among patients). The empirical results show that our proposed approach uncovers 85.71% of the implementation faults in the classifiers under test (CUT). Furthermore, we also propose an MRs minimization algorithm for the CUT, thus saving computational costs and organizational testing resources.

Computer Science↗

Universal Utility Data Exchange (UUDEX) – Security and Administration: Cybersecurity of Energy Delivery Systems (CEDS) Research and Development

A critical component of the Universal Utility Data Exchange (UUDEX) approach is the integrated security contained within its processing. This document describes how that security is designed and expected to be implemented by UUDEX Implementations (U-Implementations), including the UUDEX Server (U-Server) and UUDEX Clients (U-Clients). The UUDEX security hierarchy consists of three levels: 1. The UUDEX Instance (U-Instance) itself, which sits at the top of the hierarchy and contains the U-Server, the UUDEX Identity Authority (U-Identity Authority), and the UUDEX Administrator (U-Administrator) functions; 2. A group of one or more UUDEX Participants (U-Participants) that present “organizations” that participate in the U-Instance and contains the UUDEX Administrator Participant (U-U-Administrator Participant) function; 3. A group of one or more UUDEX Endpoints (U-Endpoints) that represent the individual UUDEX Publish Clients (U-Publish Client) responsible for supplying data to the U-Instance that is consumed by UUDEX Subscriber Clients (U-Subscriber Clients). U-Endpoints can be either autonomous devices that publish and subscribe data such as data exchange servers found in supervisory control and data acquisition and energy management systems, or they can be tied to users of applications that, for example, submit DOE OE-417 disturbance reports. U-Participants and U-Endpoints can be organized into UUDEX Groups (U-Groups). Any number of U-Participants or U-Endpoints can be members of a U-Group. A given U-Participant or U-Endpoint can be a member of multiple U-Groups, but a U-Group cannot contain other U-Groups. For example, a U-Group could be created to contain all U-Participant Transmission Operators within the purview of a Reliability Coordinator, and another U-Group could be created to contain all U-Participant Generator Operators within the purview of a Reliability Coordinator. U-Participants that are both Transmission Operators and Generator Operators would be members of both U-Groups. U-Participants, U-Endpoints, and U-Groups are used in the access control structures to provide access to individual UUDEX Subjects (U-Subjects). U-Groups are created by the U-Administrator and are managed by the U-Administrator or the designated U-Group Managers. U-Endpoints can be assigned UUDEX Roles (U-Roles) that can be used to further restrict access. U-Roles are assigned to individual U-Endpoints. For example, a U-Role of “Security Analyst” could be used to restrict which U-Endpoints can publish or subscribe security incident reports and vulnerability notifications, while a U-Role of “Transmission Planner” can be used to restrict which U-Endpoints can publish power system model updates. U-Role definitions are created by the U-Administrator, but the U-Roles are assigned to U-Endpoints by their respective UUDEX Participant Administrators (U-Participant Administrator). Because all information required to make security decisions is either included within the U-Endpoint’s X.509 digital certificate or stored in a datastore on the U-Server, all security decisions are performed and enforced within the U-Server. This reduces the complexity of the U-Client code and minimizes the chance for compromise of the integrity of the UUDEX security features.

97 MATHEMATICS AND COMPUTING↗

Designing a Comprehensive IDS Strategy for a Zero Trust Architecture Environment

Zero Trust Architecture or ZTA is a cybersecurity model for enterprises to structure their networked resources around to maintain total security externally and internally. In a Zero Trust environment, no part of the network is considered "trustworthy" and thus should be scrutinized and monitored extensively as is done in traditional "Trust But Verify" schemes at the network's perimeter. In this way, Zero Trust Architecture is a superior model for securing access to networked resources at the enterprise level. Fermilab, in pursuit of a better security posture, has decided to embrace this model of architecture for its network. Attaining this goal requires tremendous infrastructural, policy, and procedural adjustments that will affect all the lab's personnel and resources.

D'Antonio, Lucas↗

ByzSec — A Multi-layered Byzantine Resilient Architecture for Bulk Power System Protective Relays

Reliability, selectivity, and sensitivity are the fundamental attributes of any protection system, acting as the main drivers in the selection of schemes, and equipment. In high-voltage systems, microprocessor-based relays represent the industry’s preferred solution, providing engineers with a vast array of benefits. However, they remain vulnerable to cybersecurity events that may compromise their functionality. To help mitigate against potential cybersecurity risks, this paper presents a fault-tolerant, Byzantine Resilient (BR) architecture that significantly increases the cybersecurity attributes of a protection system while minimizing the amount of performance impacts and integration overheads introduced. The solution relies on an array of independent relays that utilize robust consensus methods (based on Spire [1], [2]) to ensure correct system behavior is achieved even when a relay has been compromised. Furthermore, the solution has been complemented with a custom-built Situational Awareness engine that can be used to detect and identify potential threats. The implemented solution has been developed in consultation with three hardware vendors and has been tested to comply with the performance requirements of a 345kV differential protection scheme (87T). The results indicate that the proposed architecture is a comprehensive solution that: supports the strict correctness and performance requirements of the bulk power grid while providing a cost-effective alternative that offers a seamless, long-term solution.

byzantine security, Fault Tolerant Application Sof↗

Evaluation and Demonstration of Blockchain Applicability Framework

Blockchain technology has been gaining great interest from a variety of industry sectors, including financial, food processing, and power and energy markets. Realizing the strength of blockchain technology beyond the successful application in the cryptocurrency arena, researchers have been evaluating and using blockchain for applications such as supply chain management, transactive industry (both financial and energy), system integrity, device cybersecurity, identity management, and much more. One of the unique elements of the blockchain technology that made it such a captivating technology to researchers is its plethora of features. Some of the features include smart contracts, cryptocurrency and tokenizing, immutable distributed ledger, cryptographic hashing, and digital signature. In addition, there are multiple types of blockchains, such as permissioned/private and permissionless/public, and various consensus models, such as proof-of-work, proof-of-authority, proof-of-burn, and proof-of-stake. Therefore, it is often non-trivial to determine if an application requires a blockchain. If so, what kind of blockchain and consensus is most appropriate? This paper discusses the blockchain applicability framework (BAF), which was specifically designed with the purpose to answer those questions. BAF is divided into five domains, 18 subdomains, and about 100 controls. It is designed to ingest detailed user requirements to perform a weighted evaluation that is built on mathematical constructs to determine the ideal combination of blockchain that is appropriate for an application. Along with the core logical formulation of BAF, this paper depicts the efficacy of BAF through two use cases

Gourisetti, Sri Nikhil G.↗

CyTRICS Impact-Based Prioritization Process

Cyber Testing for Resilient Industrial Control Systems™ (CyTRICS™) is the Department of Energy’s (DOE’s) program for cybersecurity vulnerability testing, digital subcomponent enumeration, and forensic assessment. CyTRICS leverages best-in-class test facilities and analytic capabilities at six DOE National Laboratories and strategic partnerships with key stakeholders including technology developers, manufacturers, asset owners and operators, and interagency partners. During the program’s development, CyTRICS established a unique methodology for prioritizing digital components within operational technology (OT) and industrial control systems (ICS) in the Energy Sector Industrial Base (ESIB) for cyber vulnerability testing. The CyTRICS prioritization process leverages multiple characteristics of systems, components, and their contextual deployment to calculate a quantification of individual digital components for CyTRICS testing. The initial version of the CyTRICS prioritization process was premised largely upon the impact which could result to an energy sector industrial control system if the digital component under testing was compromised, either through malicious means, faulty engineering, or other modes. CyTRICS has termed this process the “CyTRICS Impact-based Prioritization Process.” This paper describes the factors identified for use in the Impact-based Prioritization process and identifies the rationale for inclusion. During development, three National Laboratories piloted this prioritization process and generated prioritization scores for seven systems. Following the piloting of the process, laboratory subject matter experts (SME) validated that the numerical scores generated by the prioritization process were consistent with their knowledge of the impact that may occur should any of these systems be disrupted. The following document explains how to perform the prioritization process to generate prioritization scores for energy sector systems. After outlining assumptions required to conduct the process, it describes how to identify and elicit data which can be leveraged to evaluate a system and assign numerical values for each factor. The prioritization process uses different weights on different factors; rationale for each weight is included within the paper. Additionally, the paper includes some recommendations for future enhancements to prioritization, including lessons learned from developing and piloting the process. Finally, a comprehensive appendix includes example documents to be leveraged by those looking to execute the prioritization process.

99 GENERAL AND MISCELLANEOUS↗

Site Integration and Regulatory Considerations for a Nuclear Power Plant Colocated with Industrial Facilities: Colocation Studies for a Petroleum Refinery, Methanol Plant, and Wood Pulp Plant

This research explores the colocation of nuclear power plants (NPPs) with industrial applications. Three existing industrial sites were considered to demonstrate the siting process and illuminate technological gaps for future work. The three applications demonstrated for colocation here are a petroleum refinery, a methanol production plant, and a pulp and paper plant. This study uses a modified version of the EPRI siting criteria to explore the geological and demographic characteristics of the location of the current industrial site, as well as exploring external hazards from the industrial plant and its surrounding land use. Data was collected from public databases to estimate site characteristics. We then discuss how the site characteristics may impact the ability to colocate an NPP with an industrial application. The application site and 5 additional sites were explored for each application to give a general indication of the siting implications for an NPP in each area. The hazards for each industrial application was also explored to determine how colocation may impact reactor safety. The following gaps have been identified and should be explored in future research on colocation of NPPs with petroleum refineries, methanol plants, and pulp and paper plants: - There is a variety of industrial use, hazards, and pipelines in the surrounding area. A more thorough review of these hazards should be considered for colocation. - In general, the whole region around some applications seems to have softer soil, with implications for large site preparation costs. Further site investigations should prioritize looking into the geotechnical conditions. - Applications along coastlines are susceptible to flooding and hurricanes. The benefits of colocation should be weighed against the potential design implications. - The benefits of natural gas pipeline infrastructure in place should be explored further. If heat supply from the NPP is not required or not feasible due to the distance between the NPP and the application, there may be an opportunity to supply hydrogen to the plant through an existing pipeline. - Because there are several collocated industrial plants in the regions for the refinery and methanol plant, the benefits of sharing resources from the NPP should be explored further. This may open up additional sites for colocation. The following knowledge gaps were identified for the colocation of NPPs with these three industries, and industrial applications in general. These gaps are: - While the STAND tool contains many important characteristics for the reactor siting process, it is not calibrated for the colocation of NPPs with industrial facilities. - There are aspects of both the NPP and industrial application that need to be quantified for a siting analysis. Particularly, we need to understand the water intake requirements for NPPs and each application. - Further work may focus on adapting the STAND site comparison methodology to comparison of sites for co-location. This will involve using the data documented in this report as a starting point and performing a comprehensive and quantitative comparison. - Without spending significant resources, it would be impossible to gather data for each site to evaluate all aspects of siting. One approach to finding data and understanding its implications to siting is looking at FSARs for existing plants. For example, most sites considered in this study have small Vs30 values, indicating soft soil. However, there are NPPs located in the vicinity of most of the sites (e.g., Waterford Steam Electric Station near New Orleans) and reviewing available site characteristics and geotechnical data for these NPPs, might provide further information for siting. - The siting analysis in this study indicates that colocation of the NPP with the industrial site could be difficult based on external hazards, cooling requirements, weather, or population. We need to determine the impact of distance between the two facilities on cost and quality of energy transport. - This study did not touch on socioeconomic impacts for NPP colocation with industrial facilities. The input-output analysis methodology could be applied to the communities referenced in this study to determine the socioeconomic impact of these projects. - Similarly, the impacts of colocation on emergency planning was not explored in this study. The impacts on emergency planning infrastructure are somewhat related to the socioeconomic impacts, and could be explored using a similar methodology. - This study also did not address physical and cybersecurity, which will be important aspects of co-location [ref] . Cybersecurity will be important, regardless of the distance, but physical security will be important if the facilities are located very closely. Physical security might also be important for the steam lines between the plants, unless they are determined to be non-safety significant. - In many site l

08 HYDROGEN↗

Site Integration and Regulatory Considerations for an NPP Colocated with a Petroleum Refinery, Methanol Plant, and Wood Pulp Plant

This research explores the colocation of nuclear power plants (NPPs) with industrial applications. Three existing industrial sites were considered to demonstrate the siting process and illuminate technological gaps for future work. The three applications demonstrated for colocation here are a petroleum refinery, a methanol production plant, and a pulp and paper plant. This study uses a modified version of the EPRI siting criteria to explore the geological and demographic characteristics of the location of the current industrial site, as well as exploring external hazards from the industrial plant and its surrounding land use. Data was collected from public databases to estimate site characteristics. We then discuss how the site characteristics may impact the ability to colocate an NPP with an industrial application. The application site and 5 additional sites were explored for each application to give a general indication of the siting implications for an NPP in each area. The hazards for each industrial application was also explored to determine how colocation may impact reactor safety. The following gaps have been identified and should be explored in future research on colocation of NPPs with petroleum refineries, methanol plants, and pulp and paper plants: - There is a variety of industrial use, hazards, and pipelines in the surrounding area. A more thorough review of these hazards should be considered for colocation. - In general, the whole region around some applications seems to have softer soil, with implications for large site preparation costs. Further site investigations should prioritize looking into the geotechnical conditions. - Applications along coastlines are susceptible to flooding and hurricanes. The benefits of colocation should be weighed against the potential design implications. - The benefits of natural gas pipeline infrastructure in place should be explored further. If heat supply from the NPP is not required or not feasible due to the distance between the NPP and the application, there may be an opportunity to supply hydrogen to the plant through an existing pipeline. - Because there are several collocated industrial plants in the regions for the refinery and methanol plant, the benefits of sharing resources from the NPP should be explored further. This may open up additional sites for colocation. The following knowledge gaps were identified for the colocation of NPPs with these three industries, and industrial applications in general. These gaps are: - While the STAND tool contains many important characteristics for the reactor siting process, it is not calibrated for the colocation of NPPs with industrial facilities. - There are aspects of both the NPP and industrial application that need to be quantified for a siting analysis. Particularly, we need to understand the water intake requirements for NPPs and each application. - Further work may focus on adapting the STAND site comparison methodology to comparison of sites for co-location. This will involve using the data documented in this report as a starting point and performing a comprehensive and quantitative comparison. - Without spending significant resources, it would be impossible to gather data for each site to evaluate all aspects of siting. One approach to finding data and understanding its implications to siting is looking at FSARs for existing plants. For example, most sites considered in this study have small Vs30 values, indicating soft soil. However, there are NPPs located in the vicinity of most of the sites (e.g., Waterford Steam Electric Station near New Orleans) and reviewing available site characteristics and geotechnical data for these NPPs, might provide further information for siting. - The siting analysis in this study indicates that colocation of the NPP with the industrial site could be difficult based on external hazards, cooling requirements, weather, or population. We need to determine the impact of distance between the two facilities on cost and quality of energy transport. - This study did not touch on socioeconomic impacts for NPP colocation with industrial facilities. The input-output analysis methodology could be applied to the communities referenced in this study to determine the socioeconomic impact of these projects. - Similarly, the impacts of colocation on emergency planning was not explored in this study. The impacts on emergency planning infrastructure are somewhat related to the socioeconomic impacts, and could be explored using a similar methodology. - This study also did not address physical and cybersecurity, which will be important aspects of co-location [ref] . Cybersecurity will be important, regardless of the distance, but physical security will be important if the facilities are located very closely. Physical security might also be important for the steam lines between the plants, unless they are determined to be non-safety significant. - In many site l

08 - HYDROGEN↗

Development of a Host-Based Intrusion Detection and Control Device for Industrial Field Control Devices

Industrial control systems contain a multitude of devices deployed into the field to observe and control a physical process. Currently, most of these devices lack common host-based cybersecurity features, which can lead them to be seen as vulnerable targets. The Cymbiote device was developed to address this problem by examining multiple streams of data to determine what might indicate a potential threat, and to evaluate and execute appropriate response actions. This paper discusses the evolution of the Cymbiote device in response to evaluation and testing done on real-world hardware. Experimental results are discussed, as are the new developments that have been made to the device in response to the findings. In addition, we describe future research directions for this approach along with the experimental setup changes in response to the requirements for statistical rigor.

Rice, Theora R.↗

Consequence Prioritization Process for Potential High Consequence Events (HCE)

This document describes the process for Consequence Prioritization, the first phase of the Consequence-Driven Cyber-Informed Engineering (CCE) framework. The primary goal of Consequence Prioritization is to identify potential disruptive events that would significantly inhibit an organization’s ability to provide the critical services and functions deemed fundamental to their business mission. These disruptive events, defined as High Consequence Events (HCE), include both events that have occurred or could be realized through an attack of critical infrastructure owner assets. While other efforts have been initiated to identify and mitigate disruptive events at the national security level, such as Presidential Policy Directive 41 (PPD-41), this process is intended to be used by individual organizations to evaluate events that fall below the threshold for a national security. Described another way, Consequence Prioritization considers threats greater than those addressable by standard cyber-hygiene and includes the consideration of events that go beyond a traditional continuity of operations (COOP) perspective. Finally, Consequence Prioritization is most successful when organizations adopt a multi-disciplinary approach, engaging both cyber security and engineering expertise, as in-depth engineering perspectives are required to recognize and characterize and mitigate HCEs. Figure 1 provides a high-level overview of the prioritization process.

97 MATHEMATICS AND COMPUTING↗

Guided Resilience Self Assessment Application

Reliable electricity access is vital for everything from hospitals to national security. When grid disturbances occur, it is crucial to minimize the amount of time it takes to recover. Grid resiliency considers both the preparation for and recovery from high-impact low-frequency disturbances (HILF) such as weather events and cyber attacks. The Department of Energy (DOE) Wind Energy Technologies Office (WETO) funds the multi-laboratory Microgrids, Infrastructure Resilience, and Advanced Control Launchpad (MIRACL) project to investigate technologies to support and grow distributed wind. Researchers at Idaho National Laboratory (INL) contribute to resilience and cybersecurity efforts for the project, and have produced a resilience framework to evaluate system resilience based on individual system specifications. In order to make this framework easy for anyone to apply, I have coded a web application that allows users to input their power system qualities, goals, and perceived risks and then receive suggestions on how to improve their grid resiliency. The web application follows the seven steps in the planning stage of the framework process, allowing the user to input information about their grid and select from common goals, metrics, and hazards, as well as add their own. The application currently provides information about how to complete each step, requiring minimal prior knowledge of the framework. Future work for this application will include allowing the user to submit line drawings of their system and incorporate modeling tools so that the hazard simulations of applying the framework is completed for the user.

97 MATHEMATICS AND COMPUTING↗

Recommendations for Distributed Energy Resource Access Control

Cybersecurity for internet - connected Distributed Energy Resources (DER) is essential for the safe and reliable operation of the US power system. Many facets of DER cybersecurity are currently being investigated within different standards development organizations, research communities, and industry committees to address this critical need. This report covers DER access control guidance compiled by the Access Controls Subgroup of the SunSpec/Sandia DER Cybersecurity Workgroup. The goal of the group was to create a consensus - based technical framework to minimize the risk of unauthorized access to DER systems. The subgroup set out to define a strict control environment where users are authorized to access DER monitoring and control features through three steps: (a) user is identified using a proof-of-identity, (b) the user is authenticated by a managed database, (c) and the user is authorized for a specific level of access. DER access control also provides accountability and nonrepudiation within the power system control environment that can be used for forensic analysis and attribution in the event of a cyber-attack. This paper covers foundational requirements for a DER access control environment as well as offering a collection of possible policy, model, and mechanism implementation approaches for IEEE 1547-mandated communication protocols.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗