Search NASA⌕ Search

SEARCH · Search NASA

Results for “DATA READOUT SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

MO-AB-BRA-07: Prompt Gamma-Ray Spectroscopy for Range Verification of Clinical Proton Beams

Purpose: We developed a pre-clinical prototype system for range verification of proton pencil-beam scanning fields. The system was evaluated using phantom treatment plans delivered with a clinical dose rate. Methods: The absolute range of proton pencil-beams was verified through an optimization procedure, which matches energy- and time-resolved prompt gamma-ray measurements with models, based on cross sections for discrete prompt gamma-ray line excitations. Phantom experiments were performed with a pre-clinical prototype detector, using treatment plans delivered with a clinical pencil-beam scanning system. The detector consisted of an actively shielded lanthanum(III) bromide scintillator. Tungsten was used to collimate the gamma-rays. To support high event rates, the detector readout featured custom amplifiers and an active voltage divider for the photomultiplier. The detector signals were acquired by fast analog-to-digital converters and processed using digital algorithms. The data acquisition was also synchronized with the pencil-beam scanning and dosimetry systems. Results: We successfully acquired prompt gamma-ray spectra during the delivery of proton pencil-beams with a clinical beam current of 2 nA at the exit of the treatment head. The number of events in the primary detector ranged from 1 x 10{sup 6} to 2 x 10{sup 6} per second. In phantom experiments, non-uniform range errors were introduced by placing strips of plastic in the beam path. The magnitudes and positions of these range errors were correctly detected in two-dimensional range maps that were generated from the measurements. With our small scale prototype, a 1.0 mm standard deviation on the absolute range required about 5 x 10{sup 8} protons per delivered pencil-beam. Conclusions: Prompt gamma-ray spectroscopy to verify the absolute range of proton beams was demonstrated under clinical pencil-beam delivery conditions. A 1 mm to 2 mm range verification accuracy for a field delivering 1 Gy, appears feasible with a full scale system. This work was supported by the Federal Share of program income earned on C06-CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗

"Smart" Sensor Module

An assembly that contains a sensor, sensor-signal-conditioning circuitry, a sensor-readout analog-to-digital converter (ADC), data-storage circuitry, and a microprocessor that runs special-purpose software and communicates with one or more external computer(s) has been developed as a prototype of "smart" sensor modules for monitoring the integrity and functionality (the "health") of engineering systems. Although these modules are now being designed specifically for use on rocket-engine test stands, it is anticipated that they could also readily be designed to be incorporated into health-monitoring subsystems of such diverse engineering systems as spacecraft, aircraft, land vehicles, bridges, buildings, power plants, oilrigs, and defense installations. The figure is a simplified block diagram of the "smart" sensor module. The analog sensor readout signal is processed by the ADC, the digital output of which is fed to the microprocessor. By means of a standard RS-232 cable, the microprocessor is connected to a local personal computer (PC), from which software is downloaded into a randomaccess memory in the microprocessor. The local PC is also used to debug the software. Once the software is running, the local PC is disconnected and the module is controlled by, and all output data from the module are collected by, a remote PC via an Ethernet bus. Several smart sensor modules like this one could be connected to the same Ethernet bus and controlled by the single remote PC. The software running in the microprocessor includes driver programs for operation of the sensor, programs that implement self-assessment algorithms, programs that implement protocols for communication with the external computer( s), and programs that implement evolutionary methodologies to enable the module to improve its performance over time. The design of the module and of the health-monitoring system of which it is a part reflects the understanding that the main purpose of a health-monitoring system is to detect damage and, therefore, the health-monitoring system must be able to function effectively in the presence of damage and should be capable of distinguishing between damage to itself and damage to the system being monitored. A major benefit afforded by the self-assessment algorithms is that in the output of the module, the sensor data indicative of the health of the engineering system being monitored are coupled with a confidence factor that quantifies the degree of reliability of the data. Hence, the output includes information on the health of the sensor module itself in addition to information on the health of the engineering system being monitored.

Mahajan, Ajay↗

The NOvA power distribution system

We describe the power distribution systems and grounding schemes built for the near and far detectors of the NOvA long-baseline neutrino experiment. They are used to power the avalanche photodiodes and their thermoelectric coolers, the front-end boards that read out, digitize and time stamp the signals from the avalanche photodiodes, and the data concentrator modules used to receive and format the data from the front-end boards before sending them to a farm of computers used to build the events. Furthermore, the system powers 344,064 readout channels in the far detector and 20,192 channels in the near detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geostationary Imaging FTS (GIFTS) Data Processing: Measurement Simulation and Compression

GIFTS (Geostationary Imaging Fourier Transform Spectrometer), a forerunner of next generation geostationary satellite weather observing systems, will be built to fly on the NASA EO-3 geostationary orbit mission in 2004 to demonstrate the use of large area detector arrays and readouts. Timely high spatial resolution images and quantitative soundings of clouds, water vapor, temperature, and pollutants of the atmosphere for weather prediction and air quality monitoring will be achieved. GIFTS is novel in terms of providing many scientific returns that traditionally can only be achieved by separate advanced imaging and sounding systems. GIFTS' ability to obtain half-hourly high vertical density wind over the full earth disk is revolutionary. However, these new technologies bring forth many challenges for data transmission, archiving, and geophysical data processing. In this paper, we will focus on the aspect of data volume and downlink issues by conducting a GIFTS data compression experiment. We will discuss the scenario of using principal component analysis as a foundation for atmospheric data retrieval and compression of uncalibrated and un-normalized interferograms. The effects of compression on the degradation of the signal and noise reduction in interferogram and spectral domains will be highlighted. A simulation system developed to model the GIFTS instrument measurements is described in detail.

Huang, Hung-Lung↗

Experimental investigation of silicon photomultipliers as compact light readout systems for gamma-ray spectroscopy applications in fusion plasmas

A matrix of Silicon Photo Multipliers has been developed for light readout from a large area 1 in. × 1 in. LaBr{sub 3} crystal. The system has been characterized in the laboratory and its performance compared to that of a conventional photo multiplier tube. A pulse duration of 100 ns was achieved, which opens up to spectroscopy applications at high counting rates. The energy resolution measured using radioactive sources extrapolates to 3%–4% in the energy range E{sub γ} = 3–5 MeV, enabling gamma-ray spectroscopy measurements at good energy resolution. The results reported here are of relevance in view of the development of compact gamma-ray detectors with spectroscopy capabilities, such as an enhanced gamma-ray camera for high power fusion plasmas, where the use of photomultiplier is impeded by space limitation and sensitivity to magnetic fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AR-NE3A, a New Macromolecular Crystallography Beamline for Pharmaceutical Applications at the Photon Factory

Recent advances in high-throughput techniques for macromolecular crystallography have highlighted the importance of structure-based drug design (SBDD), and the demand for synchrotron use by pharmaceutical researchers has increased. Thus, in collaboration with Astellas Pharma Inc., we have constructed a new high-throughput macromolecular crystallography beamline, AR-NE3A, which is dedicated to SBDD. At AR-NE3A, a photon flux up to three times higher than those at existing high-throughput beams at the Photon Factory, AR-NW12A and BL-5A, can be realized at the same sample positions. Installed in the experimental hutch are a high-precision diffractometer, fast-readout, high-gain CCD detector, and sample exchange robot capable of handling more than two hundred cryo-cooled samples stored in a Dewar. To facilitate high-throughput data collection required for pharmaceutical research, fully automated data collection and processing systems have been developed. Thus, sample exchange, centering, data collection, and data processing are automatically carried out based on the user's pre-defined schedule. Although Astellas Pharma Inc. has a priority access to AR-NE3A, the remaining beam time is allocated to general academic and other industrial users.

43 PARTICLE ACCELERATORS↗

Quantum computers: Definition and implementations

The DiVincenzo criteria for implementing a quantum computer have been seminal in focusing both experimental and theoretical research in quantum-information processing. These criteria were formulated specifically for the circuit model of quantum computing. However, several new models for quantum computing (paradigms) have been proposed that do not seem to fit the criteria well. Therefore, the question is what are the general criteria for implementing quantum computers. To this end, a formal operational definition of a quantum computer is introduced. It is then shown that, according to this definition, a device is a quantum computer if it obeys the following criteria: Any quantum computer must consist of a quantum memory, with an additional structure that (1) facilitates a controlled quantum evolution of the quantum memory; (2) includes a method for information theoretic cooling of the memory; and (3) provides a readout mechanism for subsets of the quantum memory. The criteria are met when the device is scalable and operates fault tolerantly. We discuss various existing quantum computing paradigms and how they fit within this framework. Finally, we present a decision tree for selecting an avenue toward building a quantum computer. This is intended to help experimentalists determine the most natural paradigm given a particular physical implementation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Image Processing In Laser-Beam-Steering Subsystem

Conceptual design of image-processing circuitry developed for proposed tracking apparatus described in "Beam-Steering Subsystem For Laser Communication" (NPO-19069). In proposed system, desired frame rate achieved by "windowed" readout scheme in which only pixels containing and surrounding two spots read out and others skipped without being read. Image data processed rapidly and efficiently to achieve high frequency response.

Lesh, James R.↗

Combined Opto-Acoustical sensor modules for KM3NeT

KM3NeT is a future multi-cubic-kilometre water Cherenkov neutrino telescope currently entering a first construction phase. It will be located in the Mediterranean Sea and comprise about 600 vertical structures called detection units. Each of these detection units has a length of several hundred metres and is anchored to the sea bed on one side and held taut by a buoy on the other side. The detection units are thus subject to permanent movement due to sea currents. Modules holding photosensors and additional equipment are equally distributed along the detection units. The relative positions of the photosensors has to be known with an uncertainty below 20 cm in order to achieve the necessary precision for neutrino astronomy. These positions can be determined with an acoustic positioning system: dedicated acoustic emitters located at known positions and acoustic receivers along each detection unit. This article describes the approach to combine an acoustic receiver with the photosensors inside one detection module using a common power supply and data readout. The advantage of this approach lies in a reduction of underwater connectors and module configurations as well as in the compactification of the detection units integrating the auxiliary devices necessary for their successful operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Time Projection Chamber for Nuclear Security and Verification Applications

Detection of fast neutrons produced by fission is a powerful method for discovering, verifying the presence, or monitoring significant quantities of special nuclear material (SNM) at up to moderate distances. Fast neutrons are relatively rare in the natural background and can be very penetrating, even in situations when the energetic gamma-rays are well shielded. Fast neutrons point in the direction of their source and can thus be considered for use in imaging, a feature desirable for rapid, high-signal-to-noise detection of concealed SNM and for nuclear verification. We describe the development and performance of a prototype neutron time projection chamber (nTPC) and its use for directional neutron detection and high-resolution neutron imaging. The nTPC is based on {approx}0.025 m{sup 3} of a hydrogen-methane mixture and utilizes a readout system with low channel count and is optimized for low event rates. We experimentally demonstrate robust operation, reliable particle identification, event-by-event directional reconstruction over the entire 4{pi} solid angle, and insensitivity to gamma-rays. High-efficiency and high-resolution modes of operation based on single and double neutron scatters, respectively, have also been demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of a 512-Channel Faraday-Strip Array Detector Coupled to an Inductively Coupled Plasma Mattauch-Herzog Mass Spectrograph

A 512-channel Faraday-strip array detector has been developed and fitted to a Mattauch-Herzog geometry mass spectrograph for the simultaneous acquisition of multiple mass-to-charge values. Several advantages are realized by using simultaneous detection methods, including higher duty cycles, removal of correlated noise, and multianalyte transient analyses independent of spectral skew. The new 512-channel version offers narrower, more closely spaced pixels, providing improved spectral peak sampling and resolution. In addition, the electronics in the amplification stage of the new detector array incorporate a sample-and-hold feature that enables truly simultaneous interrogation of all 512 channels. While sensitivity and linear dynamic range remain impressive for this Faraday-based detector system, limits of detection and isotope ratio data have suffered slightly from leaky p-n junctions produced during the manufacture of the semiconductor-based amplification and readout stages. This paper describes the new 512-channel detector array, the current dominant noise sources, and the figures of merit for the device as pertaining to inductively coupled plasma ionization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Machine Learning on Heterogeneous, Edge, and Quantum Hardware for Particle Physics (ML-HEQUPP)

The next generation of particle physics experiments will face a new era of challenges in data acquisition, due to unprecedented data rates and volumes along with extreme environments and operational constraints. Harnessing this data for scientific discovery demands real-time inference and decision-making, intelligent data reduction, and efficient processing architectures beyond current capabilities. Crucial to the success of this experimental paradigm are several emerging technologies, such as artificial intelligence and machine learning (AI/ML) and silicon microelectronics, and the advent of quantum algorithms and processing. Their intersection includes areas of research such as low-power and low-latency devices for edge computing, heterogeneous accelerator systems, reconfigurable hardware, novel codesign and synthesis strategies, readout for cryogenic or high-radiation environments, and analog computing. This white paper presents a community-driven vision to identify and prioritize research and development opportunities in hardware-based ML systems and corresponding physics applications, contributing towards a successful transition to the new data frontier of fundamental science.

Gonski, Julia [SLAC]↗

Operational experience with the new CMS DAQ-Expert

The data acquisition (DAQ) system of the Compact Muon Solenoid (CMS) at CERN reads out the detector at the level-1 trigger accept rate of 100 kHz, assembles events with a bandwidth of 200 GB/s, provides these events to the high level-trigger running on a farm of about 30k cores and records the accepted events. Comprising custom-built and cutting edge commercial hardware and several 1000 instances of software applications, the DAQ system is complex in itself and failures cannot be completely excluded. Moreover, problems in the readout of the detectors,in the first level trigger system or in the high level trigger may provoke anomalous behaviour of the DAQ systemwhich sometimes cannot easily be differentiated from a problem in the DAQ system itself. In order to achieve high data taking efficiency with operators from the entire collaboration and without relying too heavily on the on-call experts, an expert system, the DAQ-Expert, has been developed that can pinpoint the source of most failures and give advice to the shift crew on how to recover in the quickest way. The DAQ-Expert constantly analyzes monitoring data from the DAQ system and the high level trigger by making use of logic modules written in Java that encapsulate the expert knowledge about potential operational problems. The results of the reasoning are presented to the operator in a web-based dashboard, may trigger sound alerts in the control room and are archived for post-mortem analysis - presented in a web-based timeline browser. We present the design of the DAQ-Expert and report on the operational experience since 2017, when it was first put into production.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PhotonIDs: ML-Powered Photon Identification System for Dark Count Elimination

Reliable single photon detection is the foundation for practical quantum communication and networking. However, today's superconducting nanowire single photon detector(SNSPD) inherently fails to distinguish between genuine photon events and dark counts, leading to degraded fidelity in long-distance quantum communication. In this work, we introduce PhotonIDs, a machine learning-powered photon identification system that is the first end-to-end solution for real-time discrimination between photons and dark count based on full SNSPD readout signal waveform analysis. PhotonIDs ~demonstrates: 1) an FPGA-based high-speed data acquisition platform that selectively captures the full waveform of signal only while filtering out the background data in real time; 2) an efficient signal preprocessing pipeline, and a novel pseudo-position metric that is derived from the physical temporal-spatial features of each detected event; 3) a hybrid machine learning model with near 98% accuracy achieved on photon/dark count classification. Additionally, proposed PhotonIDs ~ is evaluated on the dark count elimination performance with two real-world case studies: (1) 20 km quantum link, and (2) Erbium ion-based photon emission system. Our result demonstrates that PhotonIDs ~could improve more than 31.2 times of signal-noise-ratio~(SNR) on dark count elimination. PhotonIDs ~ marks a step forward in noise-resilient quantum communication infrastructure.

Linne, Karl C. [Chicago U.] (ORCID:000900091870358↗

Radiation-Hard Parallel Readout Circuit for Low-Frequency Voltage Signal Measurements

NASA Goddard Space Flight Center (GSFC) has successfully developed and tested a custom-designed low-noise multi-channel digitizer (MCD) application specific integrated circuit (ASIC) for operation in harsh radiation environments. The MCD-ASIC is optimized for low-frequency and low-voltage signal measurements from sensors and transducers. It has 20 input channels where each channel is comprised of auto-zeroed chopper variable-gain amplifier, post amplifier, and a second order ∑∆ modulator. ∑∆ analog-to-digital converter (ADC) relies on oversampling and noise shaping to achieve high-resolution conversion. However, the MCD-ASIC requires digital filtering and decimation to convert the output single bit streams from the ADC to useful data words. A parallel digital platform such as a field-programmable-gate-array (FPGA) is highly suitable to fully leverage the capabilities of the MCD-ASIC. The FPGA controls the MCD-ASIC via serial peripheral interface (SPI) protocol and acquires data from it. A Python-script communicates with the FPGA board through a USB interface on a cross operating platform. Using this architecture, the system is capable of monitoring up to 20 voltage readout channels simultaneously in a real-time manner. Each channel’s parameters can be programmed independently allowing maximum user versatility. In this paper, we present analysis of the analog front-end, the implementation of the digital processing unit on the FPGA, and provide noise performance results from the MCD-ASIC readout.

ASIC↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

Region of Interest Filter in DUNE DAQ

The Deep Underground Neutrino Experiment (DUNE) is the next generation neutrino experiment currently under construction. It consists of a broadband neutrino beam at Fermilab, a high precision near detector, and the largest liquid argon time projection chamber far detector ever designed at the Sanford Underground Research Facility (SURF). The Region of Interest (ROI) filter is designed for DUNE’s online Data Acquisition (DAQ) system to address data rate constraints and enable low energy physics in the <10 MeV range. The filter employs zero suppression on the detector signal, and by tuning the readout window and threshold the data rates can be reduced by >90%. Performance of the ROI is analyzed in LArsoft on MARLEY generated low energy MC events propagated through the detector simulation. Notably, the optimized ROI filter enables a lower trigger threshold for readout at ~5-10 MeV, allowing DUNE to explore low-energy physics, specifically focusing on solar boron 8 neutrinos which are relevant in this energy range. This advancement enhances DUNE's scientific capabilities, opening avenues for detailed analyses of previously inaccessible low-energy neutrino interactions.