Search NASASearch

SEARCH · Search NASA

Results for “DETERMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

313 records · Page 14

Biochar–polymer composites for 3D printing: a review

Biochar, a bio-based co-product of biofuel production via thermochemical conversion, holds potential as a filler for polymer composites to reduce costs, improve thermomechanical properties, and aid in environmental remediation. 3D-printed biochar composites have received growing interest over the past few years but have experienced difficulties such as poor layer adhesion and nozzle clogging. Currently, no literature review examines 3D-printed biochar composites and related biochar properties in-depth. This work summarizes and discusses recent studies on 3D-printed polymer and biochar composites and examines their mechanical, thermal, and additional properties that result from each study. Technical challenges in printability, such as nozzle clogging from particle size and biochar aggregation, are also discussed. Furthermore, this work discusses the variability of biochar properties resulting from the pyrolysis conditions and feedstock choice in relation to potential 3D printing outcomes. In particular, several studies reported that high lignin feedstocks could be candidates for 3D printing. The post-processing approaches of the biochar via physical and chemical methods are also introduced. Ball milling appears to hold the most promise for physical treatments due to its tunability of particle size, surface area, and functional groups, while chemical treatments with acids or alkalis are used to tailor biochar porosity and wettability. Overall, it was determined that future research needs to be done relating biochar production and post-processing methods to resulting 3D printing parameters as the number of studies is limited.

Day, Rachel [Auburn University, Auburn, AL]

Efficient electrocatalytic valorization of chlorinated organic water pollutant to ethylene

Electrochemistry can provide an efficient and sustainable way to treat environmental waters polluted by chlorinated organic compounds. However, the electrochemical valorization of 1,2-dichloroethane (DCA) is currently challenged by the lack of a catalyst that can selectively convert DCA in aqueous solutions into ethylene. Here, in this work, we report a catalyst comprising cobalt phthalocyanine molecules assembled on multiwalled carbon nanotubes that can electrochemically decompose aqueous DCA with high current and energy efficiencies. Ethylene is produced at high rates with unprecedented ~100% Faradaic efficiency across wide electrode potential and reactant concentration ranges. Kinetic studies and density functional theory calculations reveal that the rate-determining step is the first C–Cl bond breaking, which does not involve protons—a key mechanistic feature that enables cobalt phthalocyanine/carbon nanotube to efficiently catalyse DCA dechlorination and suppress the hydrogen evolution reaction. The nanotubular structure of the catalyst enables us to shape it into a flow-through electrified membrane, which we have used to demonstrate >95% DCA removal from simulated water samples with environmentally relevant DCA and electrolyte concentrations.

Choi, Chungseok [Yale Univ., New Haven, CT (United

Coercivity enhancement in hematite/permalloy heterostructures across the Morin transition

Interfacial effects between antiferromagnetic (AFM) and ferromagnetic (FM) materials have long been a center of magnetism studies. Aside from the exchange bias occurring at the AFM/FM interface, controlling the coercivity is another significant topic in magnetic recordings. The coercivity of FM materials is often determined through varying grain size, alloy composition, density of defects, etc., which is set during material growth and offers limited room for modification after growth. Hematite (α - Fe 2 O 3 ) is an AFM material that undergoes a temperature-controlled spin-flip transition, the so-called Morin transition. This transition gives an extra degree of freedom making hematite an intriguing component to study the exchange coupling when interfaced with an FM material. Here, in this work, changes in the magnetic properties of soft magnetic permalloy (Ni 81 Fe 19 , or Py) thin films grown on hematite were studied across the Morin transition. Surprisingly, these samples showed a remarkable change in coercivity during the Morin transition. We attribute this effect to the magnetic domain mixture of hematite during the Morin transition. Our findings present a novel method of controlling the coercivity of plain ferromagnetic thin films.

Antiferromagnet

Study of Key 57 Ni ⁢(𝑝,𝛾)⁢ 58 Cu Resonances to Understand 44 Ti Nucleosynthesis in Supernovae

An important validation of nucleosynthesis models of core-collapse supernovae is the comparison of radioisotope predictions to abundances inferred from observations of 𝛾 rays emitted in remnants. One such isotope, 44 Ti, is especially sensitive to the 57 Ni ⁢(𝑝,𝛾)⁢ 58 Cu reaction rate. Despite this importance, no experimentally constrained rate exists for this reaction. It is thus crucial to determine this rate. GRETINA ORRUBA: Dual Detectors for Experimental Structure Studies (GODDESS) was used along with the first use of the Enge split-pole spectrograph at Notre Dame to measure structure properties of 58 Cu via the 58 Ni ⁢( 3 He,𝑡)⁢ 58 Cu reaction. Here, the combined analysis of these complementary data sets allows for precise determination of 58 Cu level energies, and spins are constrained from analysis of the 𝛾-ray decay. 44 Ti yields were found to change by over 25% compared to previous estimates in model calculations using the new experimentally constrained reaction rate.

energy levels

Reconstruction and Dissolution of Copper Catalysts during Electrocatalytic Nitrate Reduction

Copper-based electrocatalysts are widely explored for electrochemical nitrate remediation, yet their stability under operating conditions remains poorly understood. While nanoscale and subnanoscale Cu motifs are known to restructure during the nitrate reduction reaction (NO 3 RR), how these transformations translate into irreversible material loss remains unclear. Here, we quantify Cu dissolution during NO 3 RR as a function of catalyst architecture and electrolyte chemistry using two model systems: single-atom Cu (Cu 1 ) and Cu nanoparticles (Cu NP ). Time-resolved leaching measurements, integrated with in situ X-ray absorption spectroscopy (XAS), reveal measurable Cu loss for both catalysts during NO 3 RR. Dissolution is concentrated at the initiation of electrolysis, coinciding with rapid restructuring, and depends strongly on morphology, with Cu NP consistently exhibiting greater Cu loss than Cu 1 . In situ XAS reveals that Cu 1 forms transient metallic clusters under reduction that largely redisperse upon returning to open-circuit voltage, whereas Cu NP undergoes reduction of an oxidized surface layer accompanied by sustained Cu loss during electrolysis. Notably, the presence of nitrate significantly intensifies restructuring and Cu loss, highlighting the critical role of electrolyte composition. Furthermore, these findings establish a direct link between electrochemical restructuring and Cu dissolution, unveiling electrolyte-dependent interactions as key determinants of catalyst durability in electrochemical nitrate conversion.

36 MATERIALS SCIENCE

Analysis of Gas Absorption to A Thin Liquid Film in the Presence of A Zero-Order Chemical Reaction

The paper presents a detailed theoretical analysis of the process of gas absorption to a thin liquid film adjacent to a horizontal rotating disk. The film is formed by the impingement of a controlled liquid jet at the center of the disk and subsequent radial spreading of liquid along the disk. The chemical reaction between the gas and the liquid film can be expressed as a zero-order homogeneous reaction. The process was modeled by establishing equations for the conservation of mass, momentum, and species concentration and solving them analytically. A scaling analysis was used to determine dominant transport processes. Appropriate boundary conditions were used to solve these equations to develop expressions for the local concentration of gas across the thickness of the film and distributions of film height, bulk concentration, and Sherwood number along the radius of the disk. The partial differential equation for species concentration was solved using the separation of variables technique along with the Duhamel's theorem and the final analytical solution was expressed using confluent hypergeometric functions. Tables for eigenvalues and eigenfunctions are presented for a number of reaction rate constants. A parametric study was performed using Reynolds number, Ekman number, and dimensionless reaction rate as parameters. At all radial locations, Sherwood number increased with Reynolds number (flow rate) as well as Ekman number (rate of rotation). The enhancement of mass transfer due to chemical reaction was found to be small when compared to the case of no reaction (pure absorption), but the enhancement factor was very significant when compared to pure absorption in a stagnant liquid film. The zero-order reaction processes considered in the present investigation included the absorption of oxygen in aqueous alkaline solutions of sodiumdithionite and rhodium complex catalyzed carbonylation of methanol. Present analytical results were compared to previous theoretical results for limiting conditions, and were found to have very good agreement.

S Rajagopalan

Temperature Dependence of Low‐Frequency Noise Characteristics of NiO x /β‐Ga 2 O 3 p–n Heterojunction Diodes

Temperature dependence of the low-frequency electronic noise in NiO x /β-Ga 2 O 3 p–n heterojunction diodes is reported. The noise spectral density is of the 1/f-type near room temperature but shows signatures of Lorentzian components at elevated temperatures and at higher current levels (f is the frequency). It is observed that there is an intriguing non-monotonic dependence of the noise on temperature near T = 380 K. The Raman spectroscopy of the device structure suggests material changes, which results in reduced noise above this temperature. The normalized noise spectral density in such diodes is determined to be on the order of 10 −14 cm 2 Hz −1 (f = 10 Hz) at 0.1 A cm −2 current density. In terms of the noise level, NiO x /β-Ga 2 O 3 p–n diodes perform excellently for new technology and occupy an intermediate position among devices of various designs implemented with different ultra-wide-bandgap semiconductors. The obtained results are important for understanding the electronic properties of NiO x /β-Ga 2 O 3 heterojunctions and contribute to the development of noise spectroscopy as the quality assessment tool for new electronic materials and device technologies.

1/f noise

AUTOIGNITION DELAY TIMES FOR REFORMATE GAS MIXTURES FROM METHANE GAS ENGINES

Methane slip is a prominent issue in natural gas reciprocating engines that are used in transportation and marine applications. The incomplete combustion that results in methane slip can be resolved with the introduction of hydrogen within the combustion mixture to improve methane oxidation and further enable combustion within the engine crevices where methane has previously remained unreacted. Steam methane reforming (SMR) is a common method used to produce hydrogen and can be used to design an onboard device to reduce methane slip from reciprocating engines. The development of this reformer device requires the validation of high-fidelity chemical kinetic models at the low temperatures of the crevice volumes of these engines. In this work, auto-ignition data is obtained using a shock tube at lean (φ—0.714 or λ—1.4) and stoichiometric (φ, λ = 1) equivalence ratios spanning a temperature range of 1042–1234 K at the 80-bar operating pressure of the test engine. Blends of methane, hydrogen, and reformate products from the SMR reaction are shock-heated in synthetic air, with the ignition delay time measured using an OH* chemiluminescence detector at 310 nm and a CH* detector at 430 nm. The experimental results are compared to several state-of-the-art chemical kinetic mechanisms from the literature. In general, most of the mechanisms show very good agreement with experiments at higher temperatures, with simulation results showing little deviation from experiments at lower temperatures. A sensitivity analysis was conducted, and the results reveal that the reaction H2 + CH3O2 = H + CH3O2H has a very significant role in determining low-temperature ignition delay times (IDTs) of SMR mixtures. These findings provide valuable insights into the chemical kinetics governing methane reformate combustion and contribute to the optimization of onboard reformer designs aimed at mitigating methane slip in natural gas-fueled engines.

Fraze, Matthew

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring

Selectivity mechanisms of ion intercalation in Prussian blue analogs

Prussian blue analogs (PBAs) are a family of materials with facile, reversible, and selective ion transport capability for various ions via electrochemical intercalation, owing to their vacancy structure. The large tunable compositional space of PBAs allows for manipulation of intercalation behavior and selectivity by controlling structural vacancy level through choice of transition metal centers and modifications to the synthesis process. However, a lack of understanding of the mechanisms of ion selectivity hinders the material’s design process. Here, for this work, we investigated the origins of ion selectivity using a model PBA, copper hexacyanoferrate, and focused on eight technologically and biologically prominent ions, for which we determined a sequence of selectivity: Rb + > K + > Na + > Ba 2+ > Sr 2+ ≈ Ca 2+ > Mg 2+ > Li + . We provide electrochemical, structural, and redox evidence of strong correlation between the ion identity, the dominant charge-compensating redox, and preferred occupancy site. Specifically, using synchrotron anomalous X-ray diffraction (AXRD), we reveal that monovalent ions exhibit significant association with the corner sites of the unit cell and iron redox, whereas divalent ions display affinity toward the center site with higher ratios of copper redox. Informed by selectivity results, we applied CuHCFe to Li purification and achieved 99.9% purity. Our findings demonstrate an approach to elucidating ion intercalation behavior in order to distinguish and manipulate material properties to optimize separation performance.

Prussian blue analog

The Evolution of the Moon and the Terrestrial Planets

The thermal evolutions of the Moon, Mars, Venus, and Mercury are calculated theoretically starting from cosmochemical condensation models. An assortment of geological, geochemical, and geophysical data are used to constrain both the present-day temperatures and the thermal histories of the planets' interiors. Such data imply that the planets were heated during or shortly after formation and that all the terrestrial planets started their differentiations early in their history. Initial temperatures and core formation play the most important roles in the early differentiation. The size of the planet is the primary factor in determining its present-day thermal state. The Moon, smallest in size, is characterized as a differentiated body with a crust, a thick solid mantle, and an interior region which may be partially molten. It is presently cooling rapidly and is relatively inactive tectonically. Mercury, which probably has a large core, may have a 500-km-thick solid lithosphere and a partially molten core, if it is assumed that some heat sources exist in the core. If this is not the case, the planet's interior temperatures are everywhere below the melting curve for iron. The thermal evolution is dominated by the core separation and the high conductivity of iron that makes up the bulk of Mercury. Mars, intermediate in size, is assumed to have differentiated an Fe-FeS core. While the formation of an early crust is evident, large-scale melting and differentiation of the mantle silicates has occurred at least up until 1 b.y. ago. Present-day temperature profiles indicate moderate tectonic activity at the present time. Venus is characterized as a planet not unlike the Earth in many respects. Core formation has occurred probably during the first billion years after the formation. The present-day temperatures indicate a partially molten upper mantle overlain by a 100-km-thick lithosphere and a molten Fe-Ni core. We can expect that today Venus may have tectonic processes similar to the Earth's.

M Nafi Toksöz

DS-2 Mars Microprobe Battery

In January of 1999 the NM DS-2 Mars microprobe will be launched to impact on Mars in December. The technical objectives of the missions are to demonstrate: key technologies, a passive atmospheric entry, highly integrated microelectronics which can withstand both low temperatures and high decelerations, and the capability to conduct in-situ, surface and subsurface science data acquisition. The scientific objectives are to determine if ice is present below the Martian surface, measure the local atmospheric pressure, characterize the thermal properties of the martian subsurface soil, and to estimate the vertical temperature gradient of the Martian soil. The battery requirements are 2-4 cell batteries, with voltage of 6-14 volts, capacity of 550 mAh at 80C, and 2Ah at 25C, shelf life of 2.5 years, an operating temperature of 60C and below, and the ability to withstand shock impact of 80,000 g's. The technical challenges and the approach is reviewed. The Li-SOCL2 system is reviewed, and graphs showing the current and voltage is displayed, along with the voltage over discharge time. The problems encountered during the testing were: (1) impact sensitivity, (2) cracking of the seals, and (3) delay in voltage. A new design resulted in no problems in the impact testing phase. The corrective actions for the seal problems involved: (1) pre weld fill tube, (2) an improved heat sink during case to cover weld and (3) change the seal dimensions to reduce stress. To correct the voltage delay problem the solutions involved: (1) drying the electrodes to reduce contamination by water, (2) assemblage of the cells within a week of electrode manufacture, (3) ensure electrolyte purity, and (4) provide second depassivation pulse after landing. The conclusions on further testing were that the battery can: (1) withstand anticipated shock of up to 80,000 g, (2) meet the discharge profile post shock at Mars temperatures, (3) meet the required self discharge rate and (4) meet environmental requirements.

Frank, H.

Outgassing Characterization of Common Trash Items for Disposal By Nanoracks Airlock on the International Space Station

The arrival of the Nanoracks Airlock to the International Space Station (ISS) has provided the ISS program the capability to dispose of common trash items. The concept of operations involved the crew bagging up those items into a trash bag and then utilizing the robotic arm and the airlock to jettison the trash bag. Because of the unknown thermal vacuum stability of some of the items, a molecular contamination concern was raised by the ISS program as the trash is exposed to vacuum upon the evacuation of air from the airlock and the robotic arm moving the airlock to its jettison location. In order to characterize the representative outgassing rates for ISS trash, thermal vacuum testing was performed at White Sands Test Facility. Trash was sorted into a “lower” outgassing bag and a “mixed” bag. The “mixed” trash bag contained more items that were suspected to be not vacuum stable. Load cells were chosen as the primary means for measuring mass loss. A sharp decay in the outgassing rate was observed in the first 30 minutes followed by a slower decay. As expected, the “mixed” bag lost more mass. While Quartz Crystal Microbalances (QCMs) are often utilized to measure long term outgassing rates and the sticking coefficients of contaminants at different operating temperatures for vacuum stable materials, these measurements proved difficult due to the amount and the inclusion of materials with suspect thermal vacuum stability. Because of high rates of material outgassing, the facility was unable to maintain the CQCM temperature setpoint of 80 K QCMs.. The QCMs operating at the warmer temperatures also saturated on occasion due to high levels of condensed matter. Though testing was able to confirm high risk of outgassing contamination for the program, true sticking coefficients could not be determined, available measurements are provided herein.

Alvin Y Huang

Asymmetric pathways for lithium extraction and recovery based on the two-phase equilibrium of layered oxides

Electrochemical intercalation offers a promising platform for Li + extraction. However, only limited types of electrode materials have been investigated. The challenge to broaden and tailor materials for electrochemical intercalation-based Li + extraction lies in the lack of understanding of material’s response upon co-intercalation of multiple ions, therefore, paired process design to enable reversible Li + extraction and recovery. Here, we showcase the design of asymmetric ion pathways for Li + extraction and recovery for host material with complex Li + and Na + interaction using layered cobalt oxide as a model material. The two-phase equilibrium of Na 0.48 CoO 2 and Li 0.94 CoO 2 governs Li + selectivity when a high depth of intercalation is achieved (low vacancy level). We show that the relative rate between ion exchange and intercalation is critical to determine the ion pathways. The relationship can be quantitatively compared using the average pseudo ion exchange rate (C pseudoIX ) and the intercalation rate (C inter ). The ion pathways at the three regimes with C pseudoIX > C inter , C pseudoIX ~ C inter , and C pseudoIX < C inter are constructed. By selecting the optimized ion pathway and particle size, we demonstrate 9.7×10 4 Li + selectivity with 99% purity Li + recovery from an initial 1:1000 Li: Na molar ratio solution using 115 mAh/g specific capacity.

electrochemistry

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring

NiH2 Battery Reconditioning for LEO Applications

This paper summarizes reasons for and benefits of reconditioning nickel-hydrogen (NiH2) batteries used for Low Earth Orbit (LEO) applications. NiH2 battery cells do not have the classic discharge voltage problems more commonly associated with nickel-cadmium (NiCd) cells. This is due, in part, to use of hydrogen electrodes in place of cadmium electrodes. The nickel electrode, however, does have a similar discharge voltage signature for both cell designs. This can have an impact on LEO applications where peak loads at higher relative depths of discharge can impact operations. Periodic reconditioning provides information which can be used for analyzing long term performance trends to predict usable capacity to a specified voltage level. The reconditioning process described herein involves discharging NiH2 batteries at C/20 rates or less, to an average cell voltage of 1.0 volts or less. Recharge is performed at nominal C/5 rates to specified voltage/temperature (V/T) charge levels selected to restore required capacity with minimal overcharge. Reconditioning is a process of restoring reserve capacity lost on cycling, which is commonly called the memory effect in NiCd cells. This effect is characterized by decreases in the discharge voltage curve with operational life and cycling. The end effect of reconditioning NiH2 cells may be hidden in the versatility, of that design over the NiCd cell design and its associated negative electrode fading problem. The process of deep discharge at lower rates by way of reconditioning tends to redistribute electrolyte and water in the NiH2 cell electrode stack, while improving utilization and charge efficiency. NiH2 battery reconditioning effects on life are considered beneficial and may, in fact. extend life based on NiCd experience. In any case, usable capacity data obtained from reconditioning is required for performance evaluation and trend analysis. Characterization and life tests have provided the historical data base used to determine the need for reconditioning in most battery applications. The following sections briefly describe the background of NiH2 battery reconditioning and testing at Lockheed Martin Missiles & Space (LMMS) and other aerospace companies.

Armantrout, J. D.

Conceptual design study of neutron detectors for safeguards measurement of an irradiated pebble

Nuclear material control and accounting (MC&A) of pebble-bed reactors (PBRs) is challenging because a PBR utilizes hundreds of thousands of identical, unmarked pebbles that are continuously recirculated through the core. To develop tools that enable the implementation of international safeguards, especially in the context of MC&A of spent pebbles, we designed and simulated three neutron detection concepts to determine fissile content in individual pebbles: a differential die-away (DDA) detector, a californium interrogation prompt neutron (CIPN) detector, and a passive neutron albedo reactivity (PNAR) detector using Monte Carlo calculations. Burnup calculations were performed on the spent pebbles from the PBMR-400 classic PBR. The varying neutron and gamma source terms, and isotopic compositions in the spent pebbles calculated at various burnup levels were used in the neutron detector models. DDA was found to be sensitive to the number of passes a pebble has had through the core and to the fissile content contained in a spent pebble. Optimization in the DDA design further increased the neutron count rates and thus reduced counting uncertainty. Meanwhile, passive neutron counting using the same detector body could distinguish pebbles with different numbers of passes, but its response was dominated by neutron-emitting actinides and was not sensitive to fissile content. On the other hand, the PNAR technique was not viable for a single pebble but performed reasonably for a 27-pebble array, which suggested potential use for verification measurements of containers filled with 27 or more spent pebbles.

CIPN

SCOAPE-II: A 2024 Multiplatform Measurement Campaign off the US Gulf Coast to Assess Oil and Gas Emissions on the Outer Continental Shelf

Nine years ago, the Department of Interior’s Bureau of Ocean Energy Management (BOEM), the Agency with Air Quality (AQ) jurisdiction over the Outer Continental Shelf (OCS) of the US Gulf Coast west of 87.5° W longitude, asked NASA to determine the feasibility of using satellite data to measure offshore emissions in a region of concentrated oil and natural gas (ONG) operations. To study this issue NASA and BOEM conducted the May 2019 Satellite Coastal and Oceanic Atmospheric Pollution Experiment (SCOAPE) cruise in the Gulf. SCOAPE addressed both technological and scientific issues related to measuring nitrogen dioxide (NO 2 , a common air pollutant), including contrasting near-shore and deepwater regimes. Given the April 2023 launch of the geostationary Tropospheric Emissions: Monitoring of Pollution (TEMPO) AQ satellite, a 2024 SCOAPE-II was conducted in the Gulf with both ship and aircraft measurements. We present an overview of the SCOAPE-II campaign, analysis and validation of satellite-observed NO 2 , and evaluate measurements of methane from ship, aircraft, and satellite near ONG platforms. Our SCOAPE-II results are as follows: 1) Satellite NO 2 measurements (∼13:30 local time) from the TROPOspheric Monitoring Instrument (TROPOMI) are more accurate than TEMPO’s hourly scans (8.6% vs. 23.6% mean absolute bias); a new version of TEMPO data is currently being processed; 2) ship and aircraft measurements captured dozens of NO 2 and methane plumes from ONG operations, showing that they are persistent emitters; 3) satellite measurements of methane failed to replicate ship and aircraft measurements, presenting ongoing challenges for operational emissions monitoring over the Gulf.

satellite validation