Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIAGNOSTIC EQUIPMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Prognostics and Health Management in Nuclear Power Plants: An Updated Method-Centric Review With Special Focus on Data-Driven Methods

In a carbon-constrained world, future uses of nuclear power technologies can contribute to climate change mitigation as the installed electricity generating capacity and range of applications could be much greater and more diverse than with the current plants. To preserve the nuclear industry competitiveness in the global energy market, prognostics and health management (PHM) of plant assets is expected to be important for supporting and sustaining improvements in the economics associated with operating nuclear power plants (NPPs) while maintaining their high availability. Of interest are long-term operation of the legacy fleet to 80 years through subsequent license renewals and economic operation of new builds of either light water reactors or advanced reactor designs. Recent advances in data-driven analysis methods—largely represented by those in artificial intelligence and machine learning—have enhanced applications ranging from robust anomaly detection to automated control and autonomous operation of complex systems. The NPP equipment PHM is one area where the application of these algorithmic advances can significantly improve the ability to perform asset management. This paper provides an updated method-centric review of the full PHM suite in NPPs focusing on data-driven methods and advances since the last major survey article was published in 2015. The main approaches and the state of practice are described, including those for the tasks of data acquisition, condition monitoring, diagnostics, prognostics, and planning and decision-making. Research advances in non-nuclear power applications are also included to assess findings that may be applicable to the nuclear industry, along with the opportunities and challenges when adapting these developments to NPPs. Finally, this paper identifies key research needs in regard to data availability and quality, verification and validation, and uncertainty quantification.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Lumbar spine disc heights and curvature: upright posture vs. supine compression harness

INTRODUCTION: Spinal lengthening in microgravity is thought to cause back pain in astronauts. A spinal compression harness can compress the spine to eliminate lengthening but the loading condition with harness is different than physiologic conditions. Our purpose was to compare the effect of spine compression with a harness in supine position on disk height and spinal curvature in the lumbar spine to that of upright position as measured using a vertically open magnetic resonance imaging system. METHODS: Fifteen healthy subjects volunteered. On day 1, each subject lay supine for an hour and a baseline scan of the lumbar spine was performed. After applying a load of fifty percent of body weight with the harness for thirty minutes, the lumbar spine was scanned again. On day 2, after a baseline scan, a follow up scan was performed after kneeling for thirty minutes within the gap between two vertically oriented magnetic coils. Anterior and posterior disk heights, posterior disk bulging, and spinal curvature were measured from the baseline and follow up scans. RESULTS: Anterior disk heights increased and posterior disk heights decreased compared with baseline scans both after spinal compression with harness and upright posture. The spinal curvature increased by both loading conditions of the spine. DISCUSSION: The spinal compression with specially designed harness has the same effect as the physiologic loading of the spine in the kneeling upright position. The harness shows some promise as a tool to increase the diagnostic capabilities of a conventional MR system.

Non-NASA Center↗

Design of target irradiation and diagnostic chamber to study ps-laser generated plasma as a source of singly charged ions for external injection into an electron beam ion source

High repetition-rate (~10 kHz) ps-lasers are becoming available on the market with reasonable cost and may offer several advantages compared to ns-lasers by generating nearly continuous beams of singly charged ions appropriate for the “slow” injection mode into the Electron Beam Ion Source (EBIS). To evaluate these advantages, we will perform studies of a ps-laser generated plasma using a laser with a pulse duration of 8 ps and energy up to 5 mJ per pulse. A vacuum chamber equipped with a 3D target positioner, a focusing lens, and a Faraday Cup has been designed and built for this study. Lens-to-target distance variations have been measured using a laser tracker over the whole range of horizontal and vertical translation for all five targets we will use. The variations were found to be within ±150 µm. This level of “target flatness” should be acceptable for our experimental conditions. Ion currents and ion pulse durations of various elements (from Al to Ta) will be measured for different target irradiation conditions (focal spot size and laser pulse energy). The results obtained will allow us to specify all parameters and geometry of a laser ion source based on a ps-laser to provide external ion injection into the relativistic heavy ion collider EBIS

43 PARTICLE ACCELERATORS↗

Upgrade of the Lyman-alpha diagnostic system on DIII-D for main chamber edge neutral studies

The LLAMA (Lyman Alpha Measurement Apparatus) pinhole camera diagnostic had previously been deployed on DIII-D to measure radial profiles of the Lyman-α (Ly-α) deuterium neutral line brightness across the plasma boundary in the lower chamber to infer neutral deuterium density and ionization rate profiles. This system has recently been upgraded with a new diagnostic head, named ALPACA, that also encloses two pinhole cameras and duplicates the LLAMA views in the upper chamber. Similar to LLAMA, ALPACA provides two times 20 lines of sight, viewing the plasma edge on the inboard and outboard sides with a radial resolution of ~2.5 cm (FWHM) and an effective time resolution of ~1 ms that allows for the investigation of inter-ELM dynamics. The extended Ly-α system provides better coverage to study neutrals in experiments with various plasma shapes utilizing both the upper and lower divertors. Furthermore, post-campaign calibration of the LLAMA diagnostic has successfully been demonstrated for the first time. This was facilitated by various upgrades to the calibration set-up and detailed measurements of the emissivity distribution of the Ly-α calibration source using a pinhole collimator. It was found that the sensitivity of the inboard LLAMA pinhole camera was reduced by a factor of 2.0 ± 0.2 over the course of six months of plasma operation in 2021. In conclusion, the upgraded Ly-α system, equipped with improved absolute calibration, will provide key input for neutral fueling and pedestal particle transport studies and for 2D edge transport code validation on the DIII-D tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preparing Earth Data Scientists for 'The Sexiest Job of the 21st Century'

What Exactly do Earth Data Scientists do, and What do They Need to Know, to do It? There is not one simple answer, but there are many complex answers. Data Science, and data analytics, are new and nebulas, and takes on different characteristics depending on: The subject matter being analyzed, the maturity of the research, and whether the employed subject specific analytics is descriptive, diagnostic, discoveritive, predictive, or prescriptive, in nature. In addition, in a, thus far, business driven paradigm shift, university curriculums teaching data analytics pertaining to Earth science have, as a whole, lagged behind, andor have varied in approach.This presentation attempts to breakdown and identify the many activities that Earth Data Scientists, as a profession, encounter, as well as provide case studies of specific Earth Data Scientist and data analytics efforts. I will also address the educational preparation, that best equips future Earth Data Scientists, needed to further Earth science heterogeneous data research and applications analysis. The goal of this presentation is to describe the actual need for Earth Data Scientists and the practical skills to perform Earth science data analytics, thus hoping to initiate discussion addressing a baseline set of needed expertise for educating future Earth Data Scientists.

data analytics↗

High temperature UF6 and plasma research

Research currently under way on technology for uranium plasma core reactors is reviewed. A feeder system to provide a controlled and steady flow of UF6 at rates up to 5 g/sec and temperatures up to 500 K into rf plasma test chambers operating at pressures of up to 20 atm has been developed. Plasma emission and dye laser absorption measurements have been used to estimate the radial distribution of uranium atom number density within the plasma. X-ray absorption equipment and techniques have also been employed to measure the amount of uranium in the plasma, and dc plasma torch experiments have shown variations in plasma VUV emission with temperature. Analysis of residues deposited on various test-chamber components after plasma tests reveals traces of several uranium oxides, including UO2F2, and various exhaust duct configurations with flow augmentation are under investigation as means of preventing uranium deposition. Other areas of research include off- and on-line exhaust gas diagnostics, and a UF6/Ar injection, separation and recirculation system.

Roman, W. C.↗

Testing and validating SMDS algorithms implemented in the cloud

Pacific Northwest National Laboratory (PNNL) provided technical assistance to NorthWrite Inc. under the Small Business Vouchers (SBV) Pilot. NorthWrite delivered services to owners of small commercial buildings, using a cloud-based service to monitor, control, and optimize building operations, saving energy and reducing operating costs for the owners while ensuring that occupant comfort needs were consistently met. NorthWrite had a longstanding desire to add a new suite of diagnostic capabilities to their service offering and had been trying, without success, to incorporate several diagnostic algorithms published by PNNL. These algorithms arise from research previously supported by BTO. Through the SBV awarded to NorthWrite, PNNL made available technical knowledge regarding the derivation and application of the following sets of algorithms for use in the NorthWrite Cloud-based service delivery system: • algorithms for monitoring rooftop packaged air conditioners and heat pumps (often referred to as rooftop units or RTUs) and diagnosing faults in these units, • advanced algorithms for automated fault detection and diagnosis of other equipment found in small buildings, and • algorithms for identifying, prioritizing, and assessing the economic effectiveness of implementing energy saving measures in small commercial buildings based on sensed data. The PNNL researchers involved were the original developers of these algorithms, had a unique understanding of the derivation of the algorithms, and had the source data used for this derivation. Further, the PNNL researchers had extensive experience using these algorithms in the laboratory, unique experience applying these algorithms in real-world small commercial buildings and could solve a number of key problems that NorthWrite and other users faced in using these algorithms at scale. In addition, PNNL had recently installed a pair of RTUs in a laboratory setting that were instrumented and connected with data acquisition systems that provided a unique test rig for validating the algorithms before NorthWrite began to deploy their new services in the field.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating the Viability of Compact and Portable X-Ray Systems for an Exploration Medical System in a Ground Demonstration

MOTIVATION FOR INCLUDING X-RAY CAPABILITIES For upcoming exploration missions, the need for enhanced medical care becomes critical due to extended mission durations, significant communication delays, and minimal evacuation opportunities. Previous evidence by our team has revealed that among the 119 medical conditions targeted for management during spaceflight within NASA Exploration Medical Capability’s IMPACT Condition List, at least 36 could benefit from radiography (XR). Utilizing XR for diagnosis and management is hypothesized to significantly improve management of crew health by enabling the immediate evaluation and confirmation of potential injuries or illnesses. Beyond clinical applications, XR also holds potential for non-destructive testing (NDT). This includes applications such as assessing the structural integrity of the spacecraft, analyzing surface and meteorite samples, and inspecting onboard electronics. THREE CANDIDATE X-RAY SYSTEMS CHOSEN FOR GROUND DEMONSTRATION The Exploration Medical Capability Element (ExMC) and the Exploration Medical Integrated Product Team (XMIPT) of the Mars Campaign Office initiated early background work for ground demonstrations. In FY21, ExMC published a Concept of Operations to guide requirements development. By FY23, XMIPT and yet2, a technology scouting and open innovation consulting firm, had completed a market survey and trade study to identify potential miniature XR systems. Selection criteria included commercial-off-the-shelf availability, low mass and volume, and regulatory compliance. The top three candidate devices—Remedi REMEX-KA6, MinXray Impact, and FujiFilm Xair—were acquired to characterize the requirements and capabilities of each device. To facilitate testing, phantoms, and radiographic personal protective equipment (PPE) were purchased, and a dedicated space was designated for XRS usage at Glenn Research Center. During this presentation, the mass, volume, and power requirements for each of the three piloted devices are revealed, as well as information regarding the detector, mA, and kV of the devices. GOAL AND OBJECTIVES OF A MINI XRS GROUND DEMONSTRATION The primary goal of ExMC/XMIPT technology demonstrations is to bridge the gap in available, flight-ready medical device technology by flight-testing diagnostic and treatment technologies essential for managing medical conditions during exploration missions. These technologies must adhere to vehicle constraints such as mass, volume, power, and data requirements, integrate seamlessly with medical decision-support tools, and support increasingly Earth-independent operations. There are three main objectives for the future ground demonstration of these three devices. First, we aim to determine the full capabilities of these three miniature XR systems within the context of the spaceflight environment. While medical applications are the primary focus for the miniature XR, a comprehensive exploration of non-medical uses has been initiated by an XMIPT-sponsored NASA SPARK campaign to identify collaborators. Second, we plan to establish criteria and to use insights gained from evaluating each miniature XR against those criteria to select the most suitable system among the three candidates. Third, we intend to evaluate their suitability for flight certification, which includes assessing its durability for launch, reentry, and exposure to high background radiation, as well as its compatibility with existing data architecture systems. Numerous subject matter experts from NASA and partner institutions will support these objectives.

C A Haddix↗

The development of a fiber optic Raman temperature measurement system for rocket flows

A fiber-optic Raman diagnostic system for H2/O2 rocket flows is currently under development. This system is designed for measurements of temperature and major species concentration in the combustion chamber and part of the nozzle of a 100 Newton thrust rocket currently undergoing tests. This paper describes a measurement system based on the spontaneous Raman scattering phenomenon. An analysis of the principles behind the technique is given. Software is developed to measure temperature and major species concentration by comparing theoretical Raman scattering spectra with experimentally obtained spectra. Equipment selection and experimental approach are summarized. This experimental effort is part of a program, which is in progress, to evaluate Navier-Stokes based analyses for this class of rockets.

De Groot, Wim A.↗

The Development of a Fiber Optic Raman Temperature Measurement System for Rocket Flows

A fiberoptic Raman diagnostic system for H2/O2 rocket flows is currently under development. This system is designed for measurement of temperature and major species concentration in the combustion chamber and part of the nozzle of a 100 Newton thrust rocket currently undergoing testing. This paper describes a measurement system based on the spontaneous Raman scattering phenomenon. An analysis of the principles behind the technique is given. Software is developed to measure temperature and major species concentrations by comparing theoretical Raman scattering spectra with experimentally obtained spectra. Equipment selection and experimental approach are summarized. This experimental program is part of a program, which is in progress, to evaluate Navier-Stokes based analyses for this class of rocket.

Degroot, Wim A.↗

Designing for Reliability and Robustness

Long duration spaceflight has a negative effect on the human body, and exercise countermeasures are used on-board the International Space Station (ISS) to minimize bone and muscle loss, combatting these effects. Given the importance of these hardware systems to the health of the crew, this equipment must continue to be readily available. Designing spaceflight exercise hardware to meet high reliability and availability standards has proven to be challenging throughout the time the crewmembers have been living on ISS beginning in 2000. Furthermore, restoring operational capability after a failure is clearly time-critical, but can be problematic given the challenges of troubleshooting the problem from 220 miles away. Several best-practices have been leveraged in seeking to maximize availability of these exercise systems, including designing for robustness, implementing diagnostic instrumentation, relying on user feedback, and providing ample maintenance and sparing. These factors have enhanced the reliability of hardware systems, and therefore have contributed to keeping the crewmembers healthy upon return to Earth. This paper will review the failure history for three spaceflight exercise countermeasure systems identifying lessons learned that can help improve future systems. Specifically, the Treadmill with Vibration Isolation and Stabilization System (TVIS), Cycle Ergometer with Vibration Isolation and Stabilization System (CEVIS), and the Advanced Resistive Exercise Device (ARED) will be reviewed, analyzed, and conclusions identified so as to provide guidance for improving future exercise hardware designs. These lessons learned, paired with thorough testing, offer a path towards reduced system down-time.

Svetlik, Randall G.↗

Advances in Ground Transmitters for the NASA Deep Space Network

The Deep Space Network (DSN), managed by the Jet Propulsion Laboratory for NASA, is equipped with multiple microwave transmitters ranging in average radiated power from 200 W to 400 kW. The transmitters are used for routine or emergency communication with spacecraft, for navigation, and for radio science tasks. The latest advances in transmitter engineering were implemented in a new generation of 20-kW dual-band transmitters developed for the DSN 34-m beam waveguide antennas. Innovations include additional X-band communication capability for near Earth missions, new control algorithms, automated calibration, improved and expanded computerized monitoring and diagnostics, reduced cabling, and improved maintainability. The innovations were very beneficial for the DSN 'overload' during the Mars 2003/2004 missions and will benefit other missions throughout the next decade. This paper describes the current design of the new transmitters and possible future developments.

microwaves↗

An Alternative for Emergency Preemption of Traffic Lights

An electronic communication-and-control system has been developed as a prototype of advanced means of automatically modifying the switching of traffic lights to give priority to emergency vehicles. This system could be used alternatively or in addition to other emergency traffic-light-preemption systems, including a variety of systems now in use as well as two proposed systems described in "Systems Would Preempt Traffic Lights for Emergency Vehicles" (NPO-30573), NASA Tech Briefs, Vol. 28, No. 10 (October 2004), page 36. Unlike those prior systems that depend on detection of sounds and/or lights emitted by emergency vehicles, this system is not subject to severe range limitations. This system can be retrofitted into any pre-existing traffic-light-control system, without need to modify that system other than to make a minimal number of wire connections between the two systems. This system comprises several subsystems, including a transponder and interface circuitry on each emergency vehicle, a monitoring and control unit at each intersection equipped with traffic lights, and a wide-area two-way radio communication network that connects the emergency vehicles and intersection units. Computers in the various intersections and vehicle units run special-purpose software that implements the traffic- light-preemption scheme. The operations of the intersection and vehicle units are synchronized by use of Global Positioning System (GPS) timing signals. The transponder in each vehicle estimates its own position and velocity by use of GPS signals, deductive ("dead") reckoning, data from the onboard diagnostic (OBD) computer of the vehicle, and/or triangulation of beacon signals. When the operator of an emergency vehicle turns on its flashing lights and sirens in response to a request for an emergency response, the transponder unit goes into action, reading the OBD data to determine speed and acceleration, and reading and gathering further navigational data as described above. The position, velocity, and acceleration data are combined with vehicle-identification data in a prescribed format, and the resulting set of data is transmitted to the intersections within communication range of the transponder.

Foster, Conrad↗

The Video Guidance Sensor- A Flight Proven Technology

The Video Guidance Sensor (VGS) flew on Shuttle mission STS-95 in October of 1998 to test the VGS functional characteristics on orbit. This was the second flight of the VGS, and during these two flights, both long range and short range data were gathered under a variety of lighting conditions, orbital exposure times, and temperatures. The flight experiment sensor was designed to operate from 1.5 meter range out to 110 meter range, with a field-of-view of 16 X 21 degrees. The VGS tracked its target at a 5 Hz rate and returned 6-degree-of-freedom information on the target's position and attitude relative to the sensor. The VGS was mounted in the Shuttle cargo bay, and its target was mounted on the Spartan spacecraft being carried on this mission. The VGS is a sensor designed to allow an automated vehicle to dock with a spacecraft equipped with a passive target. The VGS is a part of an Automated Rendezvous and Capture (AR&C) system being developed and tested by NASA. The orbital testing included operations with the target on the Shuttle's Remote Manipulator System (RMS) near the start of each flight of the VGS, long-range data (on the STS-95 flight) during the Shuttle rendezvous with the Spartan two days later, and some more RMS operations later in the mission. The data returned from the orbital testing included VGS diagnostics, acquisition, and tracking data, RMS positions, hand-held laser range data, tapes of the data from the VGS video camera, and orbital positioning data from the Spartan and the Shuttle to allow correlation of the VGS data with orbital best-estimate-of-truth data. The Video Guidance Sensor performed well in all phases of the testing, and the VGS is being incorporated into the ground testing of a complete automated rendezvous and docking system. Work on the development of the next generation VGS is continuing.

Howard, Richard T.↗

Limitations and Feasibility of Mini X-Ray Devices in Space Environments

LIMITATIONS AND FEASIBILITY OF MINI X-RAY DEVICES IN SPACE ENVIRONMENTS As space exploration advances toward long-duration missions, reliable medical diagnostic tools become increasingly critical. The miniature x-ray (XR) technology demonstrations by the Exploration Medical Capability (ExMC) and the Exploration Medical Integrated Product Team (XMIPT) aim to assess the feasibility and utility of miniature XR devices in spaceflight. This abstract explores the limitations of current miniature XR systems, the challenges of training crew members, the potential role of clinical decision support systems (CDSS), and the feasibility of ground-based image interpretation. We also propose the integration of miniature XR into other ExMC efforts aimed at identifying the capabilities and resources needed for future exploration class missions. One of the primary challenges with miniature XR devices is the ability to achieve specific anatomical views, particularly in the confined and weightless conditions of a spacecraft. Operators may struggle to acquire diagnostic-quality images when space is limited for proper patient positioning and the volume of the imaging device. Since space radiation and detector limitations may further impact image quality, the flexibility of the operating procedures of these devices will be critical for their success in space applications. CHALLENGES IN TRAINING CREW TO OPERATE IMAGING DEVICES Training in the skills necessary to acquire diagnostic-quality scans may be a barrier for non-clinician crewmembers. The curriculum developed for crew medical officers (CMOs) will require simplification and adaptation to fit into the highly truncated pre-flight training period. Therefore, hands-on familiarization and simulation, both pre-flight and just-in-time training during missions, will be crucial to ensuring the crew can operate the devices in real-life situations. The ability to adjust acquisition parameters must be simplified or made automatic through exam selections on equipment user interfaces, and subject and operator positioning should be assisted with laser guidance and pictorial guides. POTENTIAL FOR CDSS OR ARTIFICIAL INTELLIGENCE (AI)-ASSISTED CDSS CDSS and AI-assisted CDSS offer significant promise in assisting crew members with limited medical training. These systems could provide real-time feedback on image quality and interpretation, helping to mitigate the risks of human error during space missions. Integrating procedural guidance tools, such as virtual and augmented reality, will support crewmembers in accurately positioning patients and obtaining high-quality images. However, the success of such systems will depend on the development of robust training datasets, integration with spaceflight-rated hardware, and the medical decision-making capabilities of operators. FEASIBILITY OF GROUND INTERPRETATION AND DATA TRANSMISSION Reliance on ground-based interpretation may prove difficult for acute care during exploration class-missions due to delays in transmission with increasing distance from Earth or complete communication blackout periods. In such instances where immediate interpretation for clinical intervention is required, crew must be able to interpret the images independently or utilize AI-based assistance to do so. File sizes for XR exams can also be large if numerous images are acquired and bandwidth constraints may limit data transmissions for both radiography and ultrasound exams. FUTURE WORK AND INTEGRATION INTO THE EVIDENCE LIBRARY Future work proposes integrating miniature XR devices into NASA’s Evidence Library to address medical conditions identified as significant contributors to crew morbidity and mortality. The possibility of combining miniature XR with other imaging modalities, such as ultrasound devices, is also under investigation. In conclusion, while miniature XR technology holds potential for extraterrestrial medical systems, there are significant challenges to overcome. Training, integration of AI tools, dedicated exam protocols for microgravity, and improved data transmission systems will be key to realizing the full benefits of miniature XR technology in space.

A M Nelson↗

Exploration Laboratory Analysis FY13

The Exploration Laboratory Analysis (ELA) project supports the Exploration Medical Capability (ExMC) risk, which is stated as the Risk of Inability to Adequately Treat an Ill or Injured Crew Member, and ExMC Gap 4.05: Lack of minimally invasive in-flight laboratory capabilities with limited consumables required for diagnosing identified Exploration Medical Conditions. To mitigate this risk, the availability of inflight laboratory analysis instrumentation has been identified as an essential capability in future exploration missions. Mission architecture poses constraints on equipment and procedures that will be available to treat evidence-based medical conditions according to the Space Medicine Exploration Medical Conditions List (SMEMCL), and to perform human research studies on the International Space Station (ISS) that are supported by the Human Health and Countermeasures (HHC) element. Since there are significant similarities in the research and medical operational requirements, ELA hardware development has emerged as a joint effort between ExMC and HHC. In 2012, four significant accomplishments were achieved towards the development of exploration laboratory analysis for medical diagnostics. These achievements included (i) the development of high priority analytes for research and medical operations, (ii) the development of Level 1 functional requirements and concept of operations documentation, (iii) the selection and head-to-head competition of in-flight laboratory analysis instrumentation, and (iv) the phase one completion of the Small Business Innovation Research (SBIR) projects under the topic Smart Phone Driven Blood-Based Diagnostics. To utilize resources efficiently, the associated documentation and advanced technologies were integrated into a single ELA plan that encompasses ExMC and HHC development efforts. The requirements and high priority analytes was used in the selection of the four in-flight laboratory analysis performers. Based upon the competition results, a down select process will be performed in the upcoming year. Looking ahead, this unified effort has positioned each element for an in-flight lab analysis demonstration of select diagnostics measurements in the 2015 timeframe.

Krihak, Michael↗

Development of a Freeze-Dried CRISPR-Cas12 Sensor for Detecting Wolbachia in the Secondary Science Classroom

Training the future synthetic biology workforce requires the opportunity for students to be exposed to biotechnology concepts and activities in secondary education. Detecting Wolbachia bacteria in arthropods using polymerase chain reaction (PCR) has become a common way for secondary students to investigate and apply recombinant DNA technology in the science classroom. Despite this important activity, cutting-edge biotechnologies such as clustered regularly interspaced short palindromic repeat (CRISPR)-based diagnostics have yet to be widely implemented in the classroom. To address this gap, we present a freeze-dried CRISPR-Cas12 sensing reaction to complement traditional recombinant DNA technology education and teach synthetic biology concepts. The reactions accurately detect Wolbachia from arthropod-derived PCR samples in under 2 h and can be stored at room temperature for over a month without appreciable degradation. Here, the reactions are easy-to-use and cost less than $40 to implement for a classroom of 22 students including the cost of reusable equipment. We see these freeze-dried CRISPR-Cas12 reactions as an accessible way to incorporate synthetic biology education into the existing biology curriculum, which will expand biology educational opportunities in science, technology, engineering, and mathematics.

59 BASIC BIOLOGICAL SCIENCES↗

Intelligent diagnostics systems

Intelligent systems have been applied to today's problems and could also be applied to space operations integrity. One of these systems is the XMAN tool designed for 'troubleshooting' jet engines. XMAN is the eXpert MAiNtenance tool developed to be an expert information analysis tool which stores trending and diagnostic data on Air Force engines. XMAN operates with a 'network topology' which follows a flow chart containing engine management information reports required by the governments technical order procedures. With XMAN technology, the user is able to identify engine problems by presenting the assertions of the fault isolation logic and attempting to satisfy individual assertions by referring to the databases created by an engine monitoring system. The troubleshooting process requires interaction between the technician and the computer to acquire new evidence form auxiliary maintenance tests corroboration of analytical results to accurately diagnose equipment malfunctions. This same technology will be required for systems which are functioning in space either with an onboard crew, or with an unmanned system. The technology and lessons learned developing this technology while suggesting definite applications for its use with developing space systems are addressed.

Mcquiston, Barbara M.↗