Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

C−H Activation of Inert Arenes using a Photochemically Activated Guanidinato‐Magnesium(I) Compound

Abstract UV irradiation of solutions of a guanidinate coordinated dimagnesium(I) compound, [{(Priso)Mg} 2 ] 3 (Priso=[(DipN) 2 CNPr i 2 ] − , Dip=2,6‐diisopropylphenyl), in either benzene, toluene, the three isomers of xylene, or mesitylene, leads to facile activation of an aromatic C−H bond of the solvent in all cases, and formation of aryl/hydride bridged magnesium(II) products, [{(Priso)Mg} 2 (μ‐H)(μ‐Ar)] 4 – 9 . In contrast to similar reactions reported for β‐diketiminate coordinated counterparts of 3 , these C−H activations proceed with little regioselectivity, though they are considerably faster. Reaction of 3 with an excess of the pyridine, p ‐NC 5 H 4 Bu t (py Bu t ), gave [(Priso)Mg(py Bu t H)(py Bu t ) 2 ] 10 , presumably via reduction of the pyridine to yield a radical intermediate, [(Priso)Mg(py Bu t ⋅)(py Bu t ) 2 ] 11 , which then abstracts a proton from the reaction solvent or a reactant. DFT calculations suggest two possible pathways to the observed arene C−H activations. One of these involves photochemical cleavage of the Mg−Mg bond of 3 , generating magnesium(I) doublet radicals, (Priso)Mg⋅. These then doubly reduce the arene substrate to give “Birch‐like” products, which subsequently rearrange via C−H activation of the arene. Circumstantial evidence for the photochemical generation of transient magnesium radical species includes the fact that irradiation of a cyclohexane solution of 3 leads to an intramolecular aliphatic C−H activation process and formation of an alkyl‐bridged magnesium(II) species, [{Mg(μ‐Priso −H )} 2 ] 12 . Furthermore, irradiation of a 1 : 1 mixture of 3 and the β‐diketiminato dimagnesium(I) compound, [{( Dip Nacnac)Mg} 2 ] ( Dip Nacnac=[HC(MeCNDip) 2 ] − ), effects a “scrambling” reaction, and the near quantitative formation of an unsymmetrical dimagnesium(I) compound, [(Priso)Mg−Mg( Dip Nacnac)] 13 . Finally, the EPR spectrum (77 K) of a glassed solution of UV irradiated 3 is dominated by a broad featureless signal, indicating the presence of a doublet radical species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

AgSb(S{sub x}Se{sub 1−x}){sub 2} thin films for solar cell applications

Highlights: ► AgSb(S{sub x}Se{sub 1−x}){sub 2} thin films were formed by heating Na{sub 2}SeSO{sub 3} dipped Sb{sub 2}S{sub 3}/Ag layers. ► S/Se ratio was varied by changing the dipping time in Na{sub 2}SeSO{sub 3} solution. ► Characterized the films using XRD, XPS, SEM, Optical and electrical measurements. ► Band gap engineering of 1−1.1 eV for x = 0.51 and 0.52 respectively. ► PV Glass/FTO/CdS/AgSb(S{sub x}Se{sub 1−x}){sub 2}/C were prepared showing V{sub oc} = 410 mV, J{sub sc} = 5.7 mA/cm{sup 2}. - Abstract: Silver antimony sulfoselenide (AgSb(S{sub x}Se{sub 1−x}){sub 2}) thin films were prepared by heating glass/Sb{sub 2}S{sub 3}/Ag layers after selenization using sodium selenosulphate solution. First, Sb{sub 2}S{sub 3} thin films were deposited on glass substrates from a chemical bath containing SbCl{sub 3} and Na{sub 2}S{sub 2}O{sub 3}. Then Ag thin films were thermally evaporated onto glass/Sb{sub 2}S{sub 3}, followed by selenization by dipping in an acidic solution of Na{sub 2}SeSO{sub 3}. The duration of selenium dipping was varied as 30 min and 2 h. The heating condition was at 350 °C for 1 h in vacuum. Analysis of X-ray diffraction pattern of the thin films formed after heating showed the formation of AgSb(S{sub x}Se{sub 1−x}){sub 2}. Morphology and elemental analysis were done by scanning electron microscopy and energy dispersive X-ray detection. Depth profile of composition of the thin films was performed by X-ray Photoelectron Spectroscopy. The spectral study showed the presence of Ag, Sb, S, and Se, and the corresponding binding energy analysis confirmed the formation of AgSb(S{sub x}Se{sub 1−x}){sub 2}. Photovoltaic structures (PV) were prepared using AgSb(S{sub x}Se{sub 1−x}){sub 2} thin films as absorber and CdS thin films as window layers on FTO coated glass substrates. The PV structures were heated at 60–80 °C in air for 1 h to improve ohmic contact. Analysis of J–V characteristics of the PV structures showed V{sub oc} from 230 to 490 mV and J{sub sc} 0.28 to 5.70 mA/cm{sup 2}, under illumination of AM1.5 radiation using a solar simulator.

36 MATERIALS SCIENCE↗

Structure formation in perfluoropentacene:diindenoperylene blends and its impact on transient effects in the optical properties studied in real-time during growth

We discuss the result of the competing effects of favourable intermolecular interactions and steric incompatibilities due to the size mismatch of perfluoropentacene (PFP) and diindenoperylene (DIP) on the structure formation and associated optical properties in mixed films. Using real-time grazing incidence X-ray diffraction we investigate the size of coherently scattering islands l{sub s} as a function of film thickness and mixing ratio. We find that for PFP:DIP 1:2 blends l{sub s} is by a factor of ∼4 smaller than in pure DIP films, while l{sub s} of the PFP:DIP 2:1 blends is not significantly reduced compared with pure PFP. Yet, we observe an increase in l{sub s} with film thickness for all of the samples, independent on the mixing ratio. In parallel with the structural characterization we investigate the evolution of the absorption spectra in the visible spectral range and its dependence on l{sub s} in situ during film growth using differential reflectance spectroscopy. We observe a surprisingly strong effect of changes in the structural order on the shape of ε{sub 2,} {sub xy}(E), evident by a pronounced evolution of characteristic peaks in the thickness range from 1.6 nm to 9.6 nm. The combined results of the real-time experiments allow to identify the thickness dependent crystal grain size as the origin of the observed transient effects in the absorption spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fast magnetic response in gigahertz-band for columnar-structured Fe nanoparticle assembly

High density Fe-based ferromagnetic nanoparticle (NP) assembly is expected to have unique magnetic properties, such as superferromagnetism and super-spin-glass, different from magnetically isolated NP systems due to strong dipole interactions among the NPs. A high dipole interaction field, H{sub dip}, of ∼3.5 kOe can result in a high effective internal field to the magnetic moment of the NP, expecting for ultra-fast magnetic response, that is, a high magnetic resonance frequency, f{sub r}, of ∼10 GHz. However, for a simply molded Fe NP assembly, a low f{sub r} was observed due to inhomogeneous distribution of the internal field, implying the necessity of a unidirectional state of H{sub dip} for higher f{sub r}. In this study, we fabricated a columnar Fe NP assembly for realizing the unidirectional state of H{sub dip} by applying our uniquely developed external field-induced agglomeration method for monodispersed Fe NPs (13 nm in average size) as a function of the field (0–30 kOe) and volume fraction of the Fe NPs (0.5%–51%) in a polymer matrix with dimensions of 4 mm × 4 mm × 0.7 mm{sup t}. A columnar-structured Fe NP assembly was successfully achieved along an in-plane direction (defined as the x-axis) under optimized conditions. From static magnetization curves, induced uniaxial magnetic anisotropy was observed according to the shape of the columnar structure of the Fe NP assembly, where easy and hard axes of magnetization were realized along the parallel (x-axis) and normal directions (in-plane y-axis and z-axis in the thickness direction) to the external field during the process, respectively. Interestingly, this fabricated columnar-structured Fe NP assembly exhibited very high f{sub r} in the range from 3 to 11 GHz judging from the complex susceptibility spectra obtained. The f{sub r} values were well-scaled by a modified Snoek's-limit-law using demagnetization factors quantitatively estimated from the static magnetization curves. Thus, shape-induced anisotropy originating from the unidirectional state of H{sub dip} in the columnar structure of the Fe NP assembly plays an important role for high frequency magnetic response in the GHz-band.

36 MATERIALS SCIENCE↗

Co-sensitization of ZnO by CdS quantum dots in natural dye-sensitized solar cells with polymeric electrolytes to improve the cell stability

The CdS quantum dots (QDs) were deposited on ZnO layer by chemical bath deposition method to absorb light in the shorter wavelength region and used as photoanode in the dye sensitized solar cell (DSSCs) with natural dye extracted from Noni leaves. Microstructures of CdS-ZnO from various dipping time were characterized by XRD, FE-SEM and EDX. The results showed that the CdS is hexagonal structure and the amount of CdS increases when the dipping time increases. The maximal conversion efficiency of 0.292% was achieved by the DSSCs based on CdS QDs-sensitized ZnO film obtained from 9 min-dipping time. Furthermore, the stability of DSSCs was improved by using polymeric electrolyte. Poly (acrylic acid) (PAA) and Polyacrylamide (PAM) were introduced to CdS QDs-sensitized ZnO film from 9 min-dipping time. Each polymeric electrolyte was prepared by swelling from 0.1-2.0 %w in H2O. The maximal conversion efficiency of 0.207% was achieved for DSSCs based on CdS QDs-sensitized ZnO film with PAM 1.0% and the conversion efficiency was decreased 25% when it was left for1 hr.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetized sheath near positively biased wall between two permanent magnetic plates

The characteristics of magnetized electron sheath near a positively biased conducting wall parallel to magnetic field formed between two permanent magnetic plates were experimentally investigated in a double plasma device. The magnetic field strength between the magnetic plates is about 1200 G which is sufficient to magnetize the plasma such that the ion gyroradius is comparable to the electron Debye length. A virtual cathode (or potential dip) structure was found between the electron-rich sheath and bulk plasma. For a given neutral gas pressure, the potential minimum (dip position) remains almost the same for different positive biases on the wall. For a given bias on the wall, however, the electron sheath thickness and the potential drop from the bulk plasma to the dip decrease with the increase of the neutral gas pressure. In addition, the electron sheath and potential dip appear to be wider and deeper in the downstream side of the wall.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonmonotonous electron mobility due to structurally induced resonant coupling of subband states in an asymmetric double quantum well

We show that sharp nonmonotic variation of low temperature electron mobility μ can be achieved in GaAs/Al{sub x}Ga{sub 1-x}As barrier delta-doped double quantum well structure due to quantum mechanical transfer of subband electron wave functions within the wells. We vary the potential profile of the coupled structure as a function of the doping concentration in order to bring the subbands into resonance such that the subband energy levels anticross and the eigen states of the coupled structure equally share both the wells thereby giving rise to a dip in mobility. When the wells are of equal widths, the dip in mobility occurs under symmetric doping of the side barriers. In case of unequal well widths, the resonance can be obtained by suitable asymmetric variation of the doping concentrations. The dip in mobility becomes sharp and also the wavy nature of mobility takes a rectangular shape by increasing the barrier width. We show that the dip in mobility at resonance is governed by the interface roughness scattering through step like changes in the subband mobilities. It is also gratifying to show that the drop in mobility at the onset of occupation of second subband is substantially supressed through the quantum mechanical transfer of subband wave functions between the wells. Our results can be utilized for performance enhancement of coupled quantum well devices.

36 MATERIALS SCIENCE↗

Decoupling and tuning competing effects of different types of defects on flux creep in irradiated YBa 2 Cu 3 O 7-δ coated conductors

YBa 2 Cu 3 O 7-δ coated conductors (CCs) have achieved high critical current densities (J c ) that can be further increased through the introduction of additional defects using particle irradiation. However, these gains are accompanied by increases in the flux creep rate, a manifestation of competition between the different types of defects. In this paper, we study this competition to better understand how to design pinning landscapes that simultaneously increase J c and reduce creep. CCs grown by metal organic deposition show non-monotonic changes in the temperature-dependent creep rate, S(T). Notably, in low fields, there is a conspicuous dip to low S as the temperature (T) increases from ~20 to ~65 K. Oxygen-, proton-, and Au-irradiation substantially increase S in this temperature range. Focusing on an oxygen-irradiated CC, we investigate the contribution of different types of irradiation-induced defects to the flux creep rate. Specifically, we study S(T) as we tune the relative density of point defects to larger defects by annealing both an as-grown and an irradiated CC in O 2 at temperatures T A = 250 °C–600 °C. Finally, we observe a steady decrease in S(T > 20 K) with increasing T A , unveiling the role of pre-existing nanoparticle precipitates in creating the dip in S(T) and point defects and clusters in increasing S at intermediate temperatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Explaining low ℓ anomalies in the CMB power spectrum with resonant superstring excitations during inflation

We explore the possibility that both the suppression of the &#x2113;<!-- ℓ --> = 2 multipole moment of the power spectrum of cosmic microwave background temperature fluctuations and the possible dip for &#x2113;<!-- ℓ --> = 10 –30 can be explained as well as a possible new dip for &#x2113;<!-- ℓ --> &#x2248;<!-- ≈ --> 60 as the result of the resonant creation of sequential excitations of a fermionic (or bosonic) closed superstring that couples to the inflaton field. We consider a D = 26 closed bosonic string with one toroidal compact dimension as an illustration of how string excitations might imprint themselves on the CMB. We analyze the existence of successive momentum states, winding states or oscillations on the string as the source of the three possible dips in the power spectrum. Although the evidence of these dips are of marginal statistical significance, this might constitute the first observational evidence of successive superstring excitations in Nature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Slip and Dilation Tendency Analysis of the San Emidio Geothermal Area

Critically stressed fault segments have a relatively high likelihood of acting as fluid flow conduits (Sibson, 1994). As such, the tendency of a fault segment to slip (slip tendency; Ts; Morris et al., 1996) or to dilate (dilation tendency; Td; Ferrill et al., 1999) provides an indication of which faults or fault segments within a geothermal system are critically stressed and therefore likely to transmit geothermal fluids. The slip tendency of a surface is defined by the ratio of shear stress to normal stress on that surface: Ts = T / on (Morris et al., 1996). Dilation tendency is defined by the stress acting normal to a given surface: Td = (o1-on) / (o1-o3) (Ferrill et al., 1999). Slip and dilation were calculated using 3DStress (Southwest Research Institute). Slip and dilation tendency are both unitless ratios of the resolved stresses applied to the fault plane by ambient stress conditions. Values range from a maximum of 1, a fault plane ideally oriented to slip or dilate under ambient stress conditions to zero, a fault plane with no potential to slip or dilate. Slip and dilation tendency values were calculated for each fault in the focus study areas at, McGinness Hills, Neal Hot Springs, Patua, Salt Wells, San Emidio, and Tuscarora on fault traces. As dip is not well constrained or unknown for many faults mapped in within these we made these calculations using the dip for each fault that would yield the maximum slip tendency or dilation tendency. As such, these results should be viewed as maximum tendency of each fault to slip or dilate. The resulting along-fault and fault-to-fault variation in slip or dilation potential is a proxy for along fault and fault-to-fault variation in fluid flow conduit potential. Stress Magnitudes and directions Stress field variation within each focus area was approximated based on regional published data and the world stress database (Hickman et al., 2000; Hickman et al., 1998 Robertson-Tait et al., 2004; Hickman and Davatzes, 2010; Davatzes and Hickman, 2006; Blake and Davatzes 2011; Blake and Davatzes, 2012; Moeck et al., 2010; Moos and Ronne, 2010 and Reinecker et al., 2005) as well as local stress information if applicable. For faults within these focus systems we applied either a normal faulting stress regime where the vertical stress (sv) is larger than the maximum horizontal stress (shmax) which is larger than the minimum horizontal stress (sv>shmax>shmin) or strike-slip faulting stress regime where the maximum horizontal stress (shmax) is larger than the vertical stress (sv) which is larger than the minimum horizontal stress (shmax >sv>shmin) depending on the general tectonic province of the system. Based on visual inspection of the limited stress magnitude data in the Great Basin we used magnitudes such that shmin/shmax = .527 and shmin/sv= .46, which are consistent with complete and partial stress field determinations from Desert Peak, Coso, the Fallon area and Dixie valley (Hickman et al., 2000; Hickman et al., 1998 Robertson-Tait et al., 2004; Hickman and Davatzes, 2011; Davatzes and Hickman, 2006; Blake and Davatzes 2011; Blake and Davatzes, 2012). Slip and dilation tendency for the San Emidio geothermal field was calculated based on the faults mapped Tuscarora area (Rhodes, 2011). The San Emidio area lies in the Basin and Range Province, as such we applied a normal faulting stress regime to the San Emidio area faults, with a minimum horizontal stress direction oriented 115, based on inspection of local and regional stress determinations, as explained above. This is consistent with the shmin determined through inversion of fault data by Rhodes (2011). Under these stress conditions north-northeast striking, steeply dipping fault segments have the highest dilation tendency, while north-northeast striking 60 degrees dipping fault segments have the highest tendency to slip. Interesting, the San Emidio geothermal field lies in an area of primarily north striking faults, w...

15 GEOTHERMAL ENERGY↗

Slip and Dilation Tendency Analysis of the Salt Wells Geothermal Area

Critically stressed fault segments have a relatively high likelihood of acting as fluid flow conduits (Sibson, 1994). As such, the tendency of a fault segment to slip (slip tendency; Ts; Morris et al., 1996) or to dilate (dilation tendency; Td; Ferrill et al., 1999) provides an indication of which faults or fault segments within a geothermal system are critically stressed and therefore likely to transmit geothermal fluids. The slip tendency of a surface is defined by the ratio of shear stress to normal stress on that surface: Ts = T / on (Morris et al., 1996). Dilation tendency is defined by the stress acting normal to a given surface: Td = (o1-on) / (o1-o3) (Ferrill et al., 1999). Slip and dilation were calculated using 3DStress (Southwest Research Institute). Slip and dilation tendency are both unitless ratios of the resolved stresses applied to the fault plane by ambient stress conditions. Values range from a maximum of 1, a fault plane ideally oriented to slip or dilate under ambient stress conditions to zero, a fault plane with no potential to slip or dilate. Slip and dilation tendency values were calculated for each fault in the focus study areas at, McGinness Hills, Neal Hot Springs, Patua, Salt Wells, San Emidio, and Tuscarora on fault traces. As dip is not well constrained or unknown for many faults mapped in within these we made these calculations using the dip for each fault that would yield the maximum slip tendency or dilation tendency. As such, these results should be viewed as maximum tendency of each fault to slip or dilate. The resulting along-fault and fault-to-fault variation in slip or dilation potential is a proxy for along fault and fault-to-fault variation in fluid flow conduit potential. Stress Magnitudes and directions Stress field variation within each focus area was approximated based on regional published data and the world stress database (Hickman et al., 2000; Hickman et al., 1998 Robertson-Tait et al., 2004; Hickman and Davatzes, 2010; Davatzes and Hickman, 2006; Blake and Davatzes 2011; Blake and Davatzes, 2012; Moeck et al., 2010; Moos and Ronne, 2010 and Reinecker et al., 2005) as well as local stress information if applicable. For faults within these focus systems we applied either a normal faulting stress regime where the vertical stress (sv) is larger than the maximum horizontal stress (shmax) which is larger than the minimum horizontal stress (sv>shmax>shmin) or strike-slip faulting stress regime where the maximum horizontal stress (shmax) is larger than the vertical stress (sv) which is larger than the minimum horizontal stress (shmax >sv>shmin) depending on the general tectonic province of the system. Based on visual inspection of the limited stress magnitude data in the Great Basin we used magnitudes such that shmin/shmax = .527 and shmin/sv= .46, which are consistent with complete and partial stress field determinations from Desert Peak, Coso, the Fallon area and Dixie valley (Hickman et al., 2000; Hickman et al., 1998 Robertson-Tait et al., 2004; Hickman and Davatzes, 2011; Davatzes and Hickman, 2006; Blake and Davatzes 2011; Blake and Davatzes, 2012). Slip and dilation tendency for the Salt Wells geothermal field was calculated based on the faults mapped in the Bunejug Mountains quadrangle (Hinz et al., 2011). The Salt Wells area lies in the Basin and Range Province (N. Hinz personal comm.) As such we applied a normal faulting stress regime to the Salt Wells area faults, with a minimum horizontal stress direction oriented 105, based on inspection of local and regional stress determinations. Under these stress conditions north-northeast striking, steeply dipping fault segments have the highest dilation tendency, while north-northeast striking 60 degrees dipping fault segments have the highest tendency to slip. Several such faults intersect in high density in the core of the accommodation zone in the Bunejug Mountains and local to the Salt Wells geothermal .

15 GEOTHERMAL ENERGY↗

Slip and Dilation Tendency Analysis of Neal Hot Springs Geothermal Area

Slip and Dilation Tendency in focus areas Critically stressed fault segments have a relatively high likelihood of acting as fluid flow conduits (Sibson, 1994). As such, the tendency of a fault segment to slip (slip tendency; Ts; Morris et al., 1996) or to dilate (dilation tendency; Td; Ferrill et al., 1999) provides an indication of which faults or fault segments within a geothermal system are critically stressed and therefore likely to transmit geothermal fluids. The slip tendency of a surface is defined by the ratio of shear stress to normal stress on that surface: Ts = T / on (Morris et al., 1996). Dilation tendency is defined by the stress acting normal to a given surface: Td = (o1-on) / (o1-o3) (Ferrill et al., 1999). Slip and dilation were calculated using 3DStress (Southwest Research Institute). Slip and dilation tendency are both unitless ratios of the resolved stresses applied to the fault plane by ambient stress conditions. Values range from a maximum of 1, a fault plane ideally oriented to slip or dilate under ambient stress conditions to zero, a fault plane with no potential to slip or dilate. Slip and dilation tendency values were calculated for each fault in the focus study areas at, McGinness Hills, Neal Hot Springs, Patua, Salt Wells, San Emidio, and Tuscarora on fault traces. As dip is not well constrained or unknown for many faults mapped in within these we made these calculations using the dip for each fault that would yield the maximum slip tendency or dilation tendency. As such, these results should be viewed as maximum tendency of each fault to slip or dilate. The resulting along-fault and fault-to-fault variation in slip or dilation potential is a proxy for along fault and fault-to-fault variation in fluid flow conduit potential. Stress Magnitudes and directions Stress field variation within each focus area was approximated based on regional published data and the world stress database (Hickman et al., 2000; Hickman et al., 1998 Robertson-Tait et al., 2004; Hickman and Davatzes, 2010; Davatzes and Hickman, 2006; Blake and Davatzes 2011; Blake and Davatzes, 2012; Moeck et al., 2010; Moos and Ronne, 2010 and Reinecker et al., 2005) as well as local stress information if applicable. For faults within these focus systems we applied either a normal faulting stress regime where the vertical stress (sv) is larger than the maximum horizontal stress (shmax) which is larger than the minimum horizontal stress (sv>shmax>shmin) or strike-slip faulting stress regime where the maximum horizontal stress (shmax) is larger than the vertical stress (sv) which is larger than the minimum horizontal stress (shmax >sv>shmin) depending on the general tectonic province of the system. Based on visual inspection of the limited stress magnitude data in the Great Basin we used magnitudes such that shmin/shmax = .527 and shmin/sv= .46, which are consistent with complete and partial stress field determinations from Desert Peak, Coso, the Fallon area and Dixie valley (Hickman et al., 2000; Hickman et al., 1998 Robertson-Tait et al., 2004; Hickman and Davatzes, 2011; Davatzes and Hickman, 2006; Blake and Davatzes 2011; Blake and Davatzes, 2012). Based on inversion of fault kinematic data, Edwards (2013) interpreted that two discrete stress orientations are preserved at Neal Hot Springs. An older episode of east-west directed extension and a younger episode of southwest-northeast directed sinistral, oblique -normal extension. This interpretation is consistent with the evolution of Cenozoic tectonics in the region (Edwards, 2013). As such we applied a southwest-northeast (060) directed normal faulting stress regime, consistent with the younger extensional episode, to the Neal Hot Springs faults. Under these stress conditions northeast striking steeply dipping fault segments have the highest tendency to dilate and northeast striking 60 degrees dipping fault segments have the highest tendency to slip. Under these stress condi...

15 GEOTHERMAL ENERGY↗

3D Model of the San Emidio Geothermal Area

The San Emidio geothermal system is characterized by a left-step in a west-dipping normal fault system that bounds the western side of the Lake Range. The 3D geologic model consists of 5 geologic units and 55 faults. Overlying Jurrassic-Triassic metasedimentary basement is a ~500 m-1000 m thick section of the Miocene lower Pyramid sequence, pre- syn-extensional Quaternary sedimentary rocks and post-extensional Quaternary rocks. 15-30 degrees eastward dip of the stratigraphy is controlled by the predominant west-dipping fault set. Both geothermal production and injection are concentrated north of the step over in an area of closely spaced west dipping normal faults.

15 GEOTHERMAL ENERGY↗

Investigating the Anomalous Frequency Variations Near $T_c$ of Nb SRF Cavities

We report recent studies on the anomalous frequency variations of 1.3 GHz Nb SRF cavities near the transition temperature Tc and use them to investigate the underlying physics of state-of-the-art surface treatments. One such feature, a dip in frequency, correlates directly with the quality factor at 16 MV/m and the anti-Q slope that arise in cavities with dilute concentrations of N interstitial in the RF layer achieved via N-doping and mid temperature baking. For N interstitial, we find that the dip magnitude and Tc follow exponential relationships with the electronic mean free path. We present the first observation of the frequency dip near Tc in a cavity baked at 200 C in-situ for 11 hours, which is concurrent with the anti-Q slope, and may be driven by oxygen diffused from the native oxide, thus suggesting the possibility of ‘‘O-doping.’’ We also investigate the conductivities of two cavities that display different resonant frequency behaviors near Tc and suggest that the anti-Q slope and frequency dip phenomena may occur in the presence of interstitial N or possibly O that inhibit the formation of proximity coupled Nb nano-hydrides.

43 PARTICLE ACCELERATORS↗

Multi-messenger tests for fast-spinning newborn pulsars embedded in stripped-envelope supernovae

Fast-spinning strongly magnetized newborn neutron stars (NSs), including nascent magnetars, are popularly implemented as the engine of luminous stellar explosions. Here, we consider the scenario that they power various stripped-envelope (SE) supernovae (SNe), not only superluminous SNe Ic but also broad-line (BL) SNe Ibc and possibly some ordinary SNe Ibc. This scenario is also motivated by the hypothesis that Galactic magnetars largely originate from fast-spinning NSs as remnants of SE SNe. By consistently modeling the energy injection from magnetized wind and {sup 56}Ni decay, we show that proto-NSs with ≳10 ms rotation and a poloidal magnetic field of B{sub dip}≳5×10{sup 14} G can be harbored in ordinary SNe Ibc. On the other hand, millisecond proto-NSs can solely power BL SNe Ibc if they are born with B{sub dip}≳5×10{sup 14} G and superluminous SNe Ic with B{sub dip}≳10{sup 13} G. Then, we study how multi-messenger emission can be used to discriminate such pulsar-driven SN models from other competitive scenarios. First, high-energy X-ray and gamma-ray emission from embryonic pulsar wind nebulae can probe the underlying newborn pulsar. Follow-up observations of SE SNe using NuSTAR ∼ 50--100 days after the explosion are strongly encouraged for nearby objects. We also discuss possible effects of gravitational waves (GWs) on the spin-down of proto-NSs. If millisecond proto-NSs with B{sub dip}<a few×10{sup 13} G emit GWs through, e.g., non-axisymmetric rotation deformed by the inner toroidal fields of B{sub t}≳10{sup 16} G, the GW signal can be detectable from ordinary SNe Ibc in the Virgo cluster by Advanced LIGO, Advanced Virgo, and KAGRA.

79 ASTRONOMY AND ASTROPHYSICS↗

DISCOVERY OF RAPIDLY MOVING PARTIAL X-RAY ABSORBERS WITHIN GAMMA CASSIOPEIAE

Gamma Cassiopeiae is an enigmatic Be star with unusually strong hard X-ray emission. The Suzaku observatory detected six rapid X-ray spectral hardening events called “softness dips” in a ∼100 ks observation in 2011. All the softness dip events show symmetric softness-ratio variations, and some of them have flat bottoms apparently due to saturation. The softness dip spectra are best described by either ∼40% or ∼70% partial covering absorption to kT ∼ 12 keV plasma emission by matter with a neutral hydrogen column density of ∼(2−8) × 10{sup 21} cm{sup −2}, while the spectrum outside these dips is almost free of absorption. This result suggests the presence of two distinct X-ray-emitting spots in the γ Cas system, perhaps on a white dwarf (WD) companion with dipole mass accretion. The partial covering absorbers may be blobs in the Be stellar wind, the Be disk, or rotating around the WD companion. Weak correlations of the softness ratios to the hard X-ray flux suggest the presence of stable plasmas at kT ∼ 0.9 and 5 keV, which may originate from the Be or WD winds. The formation of a Be star and WD binary system requires mass transfer between two stars; γ Cas may have experienced such activity in the past.

79 ASTRONOMY AND ASTROPHYSICS↗

WIYN Open Cluster Study. LXXXV. Li in NGC 2243: Implications for Stellar and Galactic Evolution

High-dispersion spectra in the Li λ6708 region have been obtained and analyzed in the old, metal-deficient cluster NGC 2243. From Hydra spectra for 29 astrometric and radial velocity members, we derive rotational velocities, as well as [Fe/H], [Ca/H], [Si/H], and [Ni/H] based on 17, 1, 1, and 3 lines, respectively. Using ROBOSPECT, an automatic equivalent width measurement program, we derive [Fe/H] = −0.54 ± 0.11 (MAD), for an internal precision for the cluster [Fe/H] below 0.03 dex. Given the more restricted line set, comparable values for [Ca/H], [Si/H], and [Ni/H] are −0.48 ± 0.19, −0.44 ± 0.11, and −0.61 ± 0.06, respectively. With E(B − V) = 0.055, appropriate isochrones imply (m − M) = 13.2 ± 0.1 and an age of 3.6 ± 0.2 Gyr. Using available VLT spectra and published Li abundances, we construct an Li sample of over 100 stars extending from the tip of the giant branch to 0.5 mag below the Li dip. The Li dip is well populated and, when combined with results for NGC 6819 and Hyades/Praesepe, implies a mass/metallicity slope of 0.4 M {sub ⊙}/dex for the high-mass edge of the Li dip. The A(Li) distribution among giants reflects the degree of Li variation among the turnoff stars above the Li dip, itself a function of stellar mass and metallicity and strongly anticorrelated with a v {sub rot} distribution that dramatically narrows with age. Potential implications of these patterns for the interpretation of Li among dwarf and giant field populations, especially selection biases tied to age and metallicity, are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The double seismic zone in downgoing slabs and the viscosity of the mesosphere

The seismic zone beneath several island arcs between about 100 and 200 km depth consists of an upper zone having down-dip compression and a lower zone having down-dip tension. Several numerical models of the Aleutian arc were computed to test the hypothesis that these double seismic zones are due to sagging of the slab under its own weight. This sagging occurs because the asthenosphere (between about 100 and 200 km) provides little support or resistance to the slab, which is supported from below by the more viscous mesosphere and from above by the lithosphere. The viscosity of the mesosphere was constrained to the interval between 0.25 x 10 to the 22nd and 0.5 x 10 to the 22nd P by noting that the slab would have mainly down-dip compression at higher viscosities and mainly down-dip tension at lower viscosities. The deviatoric stress in the slab and the fault plane between the slab and the island arc is about 200-300 bars (expressed as shear stress). The models were calibrated to the observed depth and gravity anomalies in the trench.

Sleep, N. H.↗