Search NASA⌕ Search

SEARCH · Search NASA

Results for “DOUG”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Condensed-phase biogenic-anthropogenic interactions with implications for cold cloud formation

Anthropogenic and biogenic gas emissions contribute to the formation of secondary organic aerosol (SOA). When present, soot particles from fossil-fuel combustion can acquire a coating of SOA. We investigate SOA-soot biogenic-anthropogenic interactions and their impact on ice nucleation in relation to the particles’ organic phase state. SOA particles were generated from the OH oxidation of naphthalene, α-pinene, longifolene, or isoprene, with or without presence of sulfate or soot particles. Corresponding particle glass transition (T g ) and full deliquescence relative humidity (FDRH) were estimated by a numerical diffusion model. Longifolene SOA particles are solid-like and all biogenic SOA sulfate mixtures exhibit a core-shell configuration (i.e. a sulfate-rich core coated with SOA). Biogenic SOA with or without sulfate formed ice at conditions expected for homogeneous ice nucleation in agreement with respective T g and FDRH. α-pinene SOA coated soot particles nucleated ice above the homogeneous freezing temperature with soot acting as ice nuclei (IN). At lower temperatures the α-pinene SOA coating can be semisolid inducing ice nucleation. Naphthalene SOA coated soot particles acted as IN above and below the homogeneous freezing limit, which can be explained by the presence of a highly viscous SOA phase. Our results suggest that biogenic SOA does not play a significant role in mixed-phase cloud formation and the presence of sulfate further renders this even less likely. Furthermore, anthropogenic SOA may have an enhancing effect on cloud glaciation under mixed-phase and cirrus cloud conditions compared to biogenic SOA that dominate during preindustrial times or in pristine areas.

54 ENVIRONMENTAL SCIENCES↗

CAPOS: The bulge Cluster APOgee Survey: III. Spectroscopic tomography of Tonantzintla 2

Here, we performed the first detailed spectral analysis of red giant members of the relatively high-metallicity globular cluster (GC) Tononzintla 2 (Ton 2) using high-resolution near-infrared spectra collected with the Apache Point Observatory Galactic Evolution Experiment II survey (APOGEE-2), obtained as part of the bulge Cluster APOgee Survey. We investigated chemical abundances for a variety of species including the light, odd-Z, α-, Fe-peak, and neutron-capture elements from high S/N spectra of seven giant members. The derived mean cluster metallicity is [Fe/H] = –0.70 ± 0.05, with no evidence for an intrinsic metallicity spread. Ton 2 exhibits a typical α-enrichment that follows the trend for high-metallicity Galactic GCs, similar to that seen in 47 Tucanae and NGC 6380. We find a significant nitrogen spread (> 0.87 dex), and a large fraction of nitrogen-enriched stars that populate the cluster. Given the relatively high-metallicity of Ton 2, these nitrogen-enriched stars are well above the typical Galactic levels, indicating the prevalence of the multiple-population phenomenon in this cluster that also contains several stars with typical low first-generation N abundances. We also identify the presence of [Ce/Fe] abundance spread in Ton 2, which is correlated with the nitrogen enhancement, indicating that the s-process enrichment in this cluster has likely been produced by relatively low-mass asymptotic giant branch stars. Furthermore, we find a mean radial velocity of the cluster, –178.6 ± 0.86 km s –1 , with a small velocity dispersion, 2.99 ± 0.61 km s –1 , which is typical of GCs. We also find a prograde bulge-like orbit for Ton 2 that appears to be radial and highly eccentric. Finally, the considerably nitrogen-enhanced population observed in Ton 2, combined with its dynamical properties, makes this object a potential progenitor for the nitrogen-enriched field stars identified so far toward the bulge region at similar metallicity.

79 ASTRONOMY AND ASTROPHYSICS↗

Galactic ArchaeoLogIcaL ExcavatiOns (GALILEO): I. An updated census of APOGEE N-rich giants across the Milky Way

We use the 17th data release of the second phase of the Apache Point Observatory Galactic Evolution Experiment (APOGEE-2) to provide a homogenous census of N-rich red giant stars across the Milky Way (MW). We report a total of 149 newly identified N-rich field giants toward the bulge, metal-poor disk, and halo of our Galaxy. They exhibit significant enrichment in their nitrogen abundance ratios ([N/Fe] ≳ +0.5), along with simultaneous depletions in their [C/Fe] abundance ratios ([C/Fe] < +0.15), and they cover a wide range of metallicities (-1.8 < [Fe/H] < -0.7). The final sample of candidate N-rich red giant stars with globular-cluster-like (GC-like) abundance patterns from the APOGEE survey includes a grand total of ~412 unique objects. These strongly N-enhanced stars are speculated to have been stripped from GCs based on their chemical similarities with these systems. Even though we have not found any strong evidence for binary companions or signatures of pulsating variability yet, we cannot rule out the possibility that some of these objects were members of binary systems in the past and/or are currently part of a variable system. In particular, the fact that we identify such stars among the field stars in our Galaxy provides strong evidence that the nucleosynthetic process(es) producing the anomalous [N/Fe] abundance ratios occurs over a wide range of metallicities. This may provide evidence either for or against the uniqueness of the progenitor stars to GCs and/or the existence of chemical anomalies associated with likely tidally shredded clusters in massive dwarf galaxies such as “Kraken/Koala”, Gaia-Enceladus-Sausage, among others, before or during their accretion by the MW. In conclusion, a dynamical analysis reveals that the newly identified N-rich stars exhibit a wide range of dynamical characteristics throughout the MW, indicating that they were produced in a variety of Galactic environments.

59 BASIC BIOLOGICAL SCIENCES↗

APOGEE-2S Mg–Al anti-correlation of the metal-poor globular cluster NGC 2298

We present detailed elemental abundances and radial velocities of stars in the metal-poor globular cluster (GC) NGC 2298, based on near-infrared high-resolution ($R$ ~ 22 500) spectra of 12 members obtained during the second phase of the Apache Point Observatory Galactic Evolution Experiment (APOGEE-2) at Las Campanas Observatory as part of the seventeenth Data Release (DR 17) of the Sloan Digital Sky Survey IV (SDSS-IV). We employed the Brussels Automatic Code for Characterizing High accuracy Spectra (BACCHUS) software to investigate abundances for a variety of species including α elements (Mg, Si, and Ca), the odd-Z element Al, and iron-peak elements (Fe and Ni) located in the innermost regions of NGC 2298. We find a mean and median metallicity [Fe/H] = -1.76 and -1.75, respectively, with a star-to-star spread of 0.14 dex, which is compatible with the internal measurement errors. Thus, we find no evidence for an intrinsic [Fe/H] abundance spread in NGC 2298. The typical $α$-element enrichment in NGC 2298 is overabundant relative to the Sun, and it follows the trend of other metal-poor GCs. We confirm the existence of an Al-enhanced population in this cluster, which is clearly anti-correlated with Mg, indicating the prevalence of the multiple-population phenomenon in NGC 2298.

79 ASTRONOMY AND ASTROPHYSICS↗

The Polarized SRF Gun Experiment

RF electron guns are capable of producing electron bunches with high brightness, which outperform DC electron guns and may even be able to provide electron beams for the ILC without the need for a damping ring. However, all successful existing guns for polarized electrons are DC guns because the environment inside an RF gun is hostile to the GaAs cathode material necessary for polarization. While the typical vacuum pressure in a DC gun is better than 10{sup -11} torr the vacuum in an RF gun is in the order of 10{sup -9} torr. Experiments at BINP Novosibirsk show that this leads to strong ion back-bombardment and generation of dark currents, which destroy the GaAs cathode in a short time. The situation might be much more favorable in a (super-conducting) SRF gun. The cryogenic pumping of the gun cavity walls may make it possible to maintain a vacuum close to 10{sup -12} torr, solving the problem of ion bombardment and dark currents. Of concern would be contamination of the gun cavity by evaporating cathode material. This report describes an experiment that Brookhaven National Laboratory (BNL) in collaboration with Advanced Energy Systems (AES) is conducting to answer these questions.

43 PARTICLE ACCELERATORS↗

Implanter Source Life and Stability Improvement Using In-Situ Chemical Cleaning

Current 300 mm fabs rely heavily on automation to provide manufacturing efficiency. While implant processes and equipment follow this trend, tool availability and maintenance cycles are often driven by the ion source and adjacent areas which suffer from premature failures due to unwanted material deposits. While working in a high volume production environment, side by side comparative data has been collected on two tools running similar processes, with one tool having integrated in-situ cleaning cycles and the other with no in-situ cleaning. This paper will discuss significant improvements achieved in beam stability, glitch rate, ion source lifetime and maintenance cycles which were achieved on the tool with integrated in-situ cleaning. A program was established at Texas Instruments' DMOS6 wafer fab in early 2007 to explore and document process and equipment performance. Other critical areas, such as particle and metals contamination will be discussed with inferences as to potential yield improvements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fissile Material Detection by Differential Die Away Analysis

Detection and interdiction of Special Nuclear Material (SNM) in transportation is one of the most critical security issues facing the United States. Active inspection by inducing fission in fissile nuclear materials, such as {sup 235}U and {sup 239}Pu, provides several strong and unique signatures that make the detection of concealed nuclear materials technically very feasible. Differential Die-Away Analysis (DDAA) is a very efficient, active neutron-based technique that uses the abundant prompt fission neutrons signature. It benefits from high penetrability of the probing and signature neutrons, high fission cross section, high detection sensitivity, ease of deployment and relatively low cost. DDAA can use any neutron source or energy as long as it can be suitably pulsed. The neutron generator produces pulses of neutrons that are directed into a cargo. As each pulse passes through the cargo, the neutrons are thermalized and absorbed. If SNM is present, the thermalized neutrons create a new source of (fission) neutrons with a distinctive time profile. An efficient laboratory system was designed, fabricated and tested under a US Government DHS DNDO contract. It was shown that a small uranium sample can be detected in a large variety of cargo types and configurations within practical measurement times using commercial compact (d,T) sources. Using stronger sources and wider detector distribution will further cut inspection time. The system can validate or clear alarms from a primary inspection system such as an automated x-ray system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Priori Method of Using Photon Activation Analysis to Determine Unknown Trace Element Concentrations in NIST Standards

Photon activation analysis detected elements in two NIST standards that did not have reported concentration values. A method is currently being developed to infer these concentrations by using scaling parameters and the appropriate known quantities within the NIST standard itself. Scaling parameters include: threshold, peak and endpoint energies; photo-nuclear cross sections for specific isotopes; Bremstrahlung spectrum; target thickness; and photon flux. Photo-nuclear cross sections and energies from the unknown elements must also be known. With these quantities, the same integral was performed for both the known and unknown elements resulting in an inference of the concentration of the un-reported element based on the reported value. Since Rb and Mn were elements that were reported in the standards, and because they had well-identified peaks, they were used as the standards of inference to determine concentrations of the unreported elements of As, I, Nb, Y, and Zr. This method was tested by choosing other known elements within the standards and inferring a value based on the stated procedure. The reported value of Mn in the first NIST standard was 403{+-}15 ppm and the reported value of Ca in the second NIST standard was 87000 ppm (no reported uncertainty). The inferred concentrations were 370{+-}23 ppm and 80200{+-}8700 ppm respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Polarized SRF Gun Experiment

An experiment is under way to prove the feasibility of a super-conducting RF gun for the production of polarized electrons. We report on the progress of the experiment and on simulations predicting the possibility of success.

43 PARTICLE ACCELERATORS↗

Top-Quark Physics Results From The Tevatron

Tevatron's record luminosities enable a program systematically addressing the physics of the top quark. The CDF and DOe experiments are pioneering measurements across the full breadth of topics. Some of their most recent results are summarized.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Using Photon Activation Analysis To Determine Concentrations Of Unknown Components In Reference Materials

Using certified multi-element reference materials for instrumental analyses one frequently is confronted with the embarrassing fact that the concentration of some desired elements are not given in the respective certificate, nonetheless are detectable, e.g. by photon activation analysis (PAA). However, these elements might be determinable with sufficient quality of the results using scaling parameters and the well-known quantities of a reference element within the reference material itself. Scaling parameters include: activation threshold energy, Giant Dipole Resonance (GDR) peak and endpoint energy of the bremsstrahlung continuum; integrated photo-nuclear cross sections for the isotopes of the reference element; bremsstrahlung continuum integral; target thickness; photon flux density. Photo-nuclear cross sections from the unreferenced elements must be known, too. With these quantities, the integral was obtained for both the known and unknown elements resulting in an inference of the concentration of the unreported element based upon the reported value, thus also the concentration of the unreferenced element in the reference material. A similar method to determine elements using the basic nuclear and experimental data has been developed for thermal neutron activation analysis some time ago (k{sub 0} Method).

07 ISOTOPE AND RADIATION SOURCES↗

Obtaining anisotropic velocity data for proper depth seismic imaging

The paper deals with the problem of obtaining anisotropic velocity data due to continuous acoustic impedance-based measurements while scanning in the axial direction along the walls of the borehole. Diagrams of full conductivity of the piezoceramic transducer were used to derive anisotropy parameters of the rock sample. The measurements are aimed to support accurate depth imaging of seismic data. Understanding these common anisotropy effects is important when interpreting data where it is present.

58 GEOSCIENCES↗

Towards nanometer period gratings for hard x-ray phase-contrast imaging

Transmission grating-based x-ray interferometers have been developed into wide-field imaging devices that are sensitive to x-ray refraction and diffraction in the sample. While current grating designs rely on UV and x-ray lithography processes to produce periodic vertical structures, it becomes prohibitively difficult to make the grating periods below 1 - 2 microns due to the high aspect ratios of the structures. Since the phase-contrast sensitivity is inversely related to the grating period, we describe a new grating design for sub-micron to nanometer grating periods. In this design, multiple bi-layers of two alternating materials are deposited on a stair like substrate, and mostly on the floor surfaces of the steps only. The incident x-ray beam is parallel to the planes of the layers (side illumination). Thus, the multilayer structure on each step serves as a micro grating whose grating period is the thickness of a bi-layer. The array of micro gratings over the whole length of the stair can act as a single continuous grating, when certain continuity conditions between neighboring steps are met. Since the layer thickness can be as small as tens of nanometers, as has been demonstrated in multilayer x-ray zone plates, this design allows nanometer grating periods over large grating areas. Here we describe a prototype intensity grating of 440 nm period. We show x-ray projection images of the grating which were obtained by contact lithography.

36 MATERIALS SCIENCE↗

Analytical and experimental studies of leak location and environment characterization for the international space station

The International Space Station program is developing a robotically-operated leak locator tool to be used externally. The tool would consist of a Residual Gas Analyzer for partial pressure measurements and a full range pressure gauge for total pressure measurements. The primary application is to demonstrate the ability to detect NH{sub 3} coolant leaks in the ISS thermal control system. An analytical model of leak plume physics is presented that can account for effusive flow as well as plumes produced by sonic orifices and thruster operations. This model is used along with knowledge of typical RGA and full range gauge performance to analyze the expected instrument sensitivity to ISS leaks of various sizes and relative locations (“directionality”). The paper also presents experimental results of leak simulation testing in a large thermal vacuum chamber at NASA Goddard Space Flight Center. This test characterized instrument sensitivity as a function of leak rates ranging from 1 lb{sub m/}/yr. to about 1 lb{sub m}/day. This data may represent the first measurements collected by an RGA or ion gauge system monitoring off-axis point sources as a function of location and orientation. Test results are compared to the analytical model and used to propose strategies for on-orbit leak location and environment characterization using the proposed instrument while taking into account local ISS conditions and the effects of ram/wake flows and structural shadowing within low Earth orbit.

42 ENGINEERING↗

The impact of sodium on the sub-bandgap states in CZTSe and CZTS

We compare the optically active sub-bandgap states in polycrystalline Cu{sub 2}ZnSnSe{sub 4} (CZTSe) and Cu{sub 2}ZnSnS{sub 4} (CZTS) thin films as a function of sodium content. In all samples studied, we find that CZTSe has a lower concentration of radiative defect-derived states compared to CZTS and that the states are also shallower in CZTSe compared to CZTS. Further, we find that sodium impacts the relative ratios of two sub-bandgap peaks in the 4 K photoluminescence (PL) spectra of CZTSe (one at ∼0.85 eV and another at ∼0.92 eV). We propose that both of these sub-bandgap peaks stem from intrinsic point defects in CZTSe rather than from electronic states introduced by sodium; this is supported by a measurement on a sodium-free single-crystal of CZTSe. We also show that films with stronger emission through the shallower sub-bandgap states at 4 K display room-temperature PL closer to the bandgap energy. For all sodium quantities studied, one broad PL peak is observed in the 4 K PL spectrum of CZTS which also shifts towards the band edge with increasing sodium. A reduced overall defect density and the fact that the states that are present are shallower together may help account for the lower V{sub OC} deficits in CZTSe and the empirical observations that sodium improves device performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Assessing Detonator Health Using Rogowski Coil Data

The Rogowski coil is commonly employed to measure rapid changes of electrical currents, especially in high power applications. Here we report the use of the coil to reveal subtle details of exploding bridgewire (EBW) detonator initiation and how the initiation is affected by aging. Detonator accelerated aging studies are aimed at understanding aging mechanisms and enabling predictive capabilities for aging. Rogowski Coil data from detonator accelerated aging studies offer a wealth of information regarding the electrical health of detonator, which is an important and complementary part of a comprehensive accelerated aging study. Herein we present the results of a variety of accelerated aging tests in detonators (thermal cycling, low power current damage, etc.) and the results that the Rogowski Coil affords us and how they inform us about the condition of the detonator.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Demonstration of a two-dimensional divertor Thomson scattering system on DIII-D

Recent upgrades providing two-dimensional divertor Thomson scattering (DTS-2D) measurements of T e and n e during a DIII-D plasma shot and a thorough description of system components and their functionality are presented. This system expands the capabilities of the existing single divertor Floor measurement location by introducing seven additional laser beam path options in the poloidal plane, spanning major radii from 1.062 to 1.335 m. The system redirects ~1 J, 50 Hz Nd:YAG laser pulses to the new beam paths within 20 ms, stepping through each path on the divertor Floor every 200 ms during a plasma shot. The laser is redirected using an ex-vessel, fast-steering mirror to one of eight in-vessel beam paths oriented underneath the vessel tiles. Up to eleven measurement positions per beam path, from –1.35 to –1.13 m below the machine midplane, are available by dynamically refocusing the ex-vessel collection fiber array using a high-speed linear stage. As a result, current measurement positions above the divertor Shelf are retained via a hole in the fixed, in-vessel mirror, allowing laser pass through.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗