Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data, Modeling, and Analysis Program”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

244 records · Page 14

Multiscale and Machine Learning Modeling for Process-informed Microstructure Prediction in Additively Manufactured Materials Using MALAMUTE

Advanced Materials and Manufacturing Technologies (AMMT) program under the Department of Energy Office of Nuclear Energy, aims to develop and qualify additively-manufactured materials for nuclear applications. The key challenges to these efforts are the microstructural variabilities observed on the AM products and their impact on the properties and performance of the material in extreme environments. AMMT is using a combination of high-through-put experimental and modeling techniques to accelerate the qualification efforts. Conventionally, in-situ and ex-situ characterizations and testing are performed to correlate different aspects of the AM process to the final product and its performance. However, adopting a trial-and-error approach to experimentally evaluate the vast range of process parameters required to capture the microstructural variabilities is cost-prohibitive. Modeling and simulation provide a comparatively inexpensive way to understand and correlate the microstructural evolution to the processing conditions. The modeling and simulation work-packages within the AMMT program aims to use physics-based and machine learning modeling capabilities to develop a digital twin for AM that can correlate the process conditions to the final product and establish a process-structure-property-performance (PSPP) correlation for AM materials. The melting and subsequent solidification that occurs during the AM process is a complex phenomenon that requires multiscale multiphysics analysis. Idaho National Laboratory’s (INL) Multiphysics Object-Oriented Simulation Environment (MOOSE), specifically the MOOSE Application Library for Advanced Manufacturing UTilitiEs (MALAMUTE) software, provides an ideal platform for developing the multiphysics multiscale model to explore the intricacies of the microstructural evolution during the AM processes within a single framework. Furthermore, given that such full-fidelity simulations can be computationally intensive, reduced order models are necessary to explore the PSPP space for AM materials in an efficient, reliable, and cost-effective way. This work package focuses on understanding the role of process variabilities on the various microstructural characteristics of the AM materials. Microstructures unique to AM materials, such as compositional micro-heterogeneity and dislocation cells, are of particular interest here since they can influence the creep properties and radiation performance. In fiscal year (FY) 24, we significantly advanced upon our work in the last fiscal year, both on physics-based and ML models. The alloy solidification model available in MOOSE has been extended to incorporate the thermodynamic properties and free energy relevant to 316SS. The model demonstrates the Cr segregation that occurs during solidifcation. It is demonstrated that rate of solidification and solute segregation is primarily influence by the cooling rate dictating the level of freezing. This work captures the microstructural variabilities at the subgrain level that are often missing in the part-scale models. With an aim to connect the microstructural evolution model to realistic process conditions, a reduced order model is developed for predicting the thermal conditions around meltpool from high-fidelity process simulations. Furthermore, machine learning approach is used to accelerate the temperature prediction during the AM process. In the following years, MALAMUTE will be used to connect different aspects of the models and quantitatively predict the microstructural evolution. The developed ML-based surrogate model will consider the process conditions as the input to predict the microstructural features in a cost-effective way. The generated microstructures can be used by other work packages under AMMT to evaluate the properties and environmental response of the material at the mesoscale. Thus, this work help identify the key microstructural features at the subgrain level that are significant in property/performance prediction of the AM products. This work will provide inputs to the large-scale process variability models to reevaluate and validate assumptions/simplifications made in the part-scale models. Furthermore, through active learning this work will help identify the data need from both modeling and experimental sides for development of a robust digital twin for AM.

36 MATERIALS SCIENCE↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Marginal Soils Index Analysis & Geospatial Data

This data package contains output files associated with the Mongird et al. paper entitled "Can US power grid expansion avoid prime agricultural lands?" and is organized into four dataset directories. Each dataset is described in more detail below. 1. Marginal Soils Index Analysis Description: This folder contains a csv file with land needs and availability by state, power generating technology type, and scenario in 2050 when suitable siting areas are additionally constrained to areas with increasing levels of soil marginality. Files: msi_constrained_siting_availability_2050.csv Variables: Scenario - Projected 2050 scenario name State - US state abbreviation Technology - Generating technology type solar = solar photovoltaic gas_cc_re = natural gas combined cycle (recirculating cooling) wind = onshore wind gas_cc_ccs_re = natural gas combined cycle with carbon capture sequestration (recirculating cooling) gas_cc_dry = natural gas combined cycle with (dry cooling) gas_cc_pond = natural gas combined cycle with (pond cooling) coal_conv_ccs_re = conventional coal with carbon capture sequestration (recirculating cooling) Req_Capacity_MW - The amount of rated capacity required in 2050 of the given technology type in the given state and under the given scenario from the capacity expansion plan Req_Capacity_Factor - The assumed capacity factor (fraction between 0 and 1) for the given technology type in the given state and under the given scenario by the capacity expansion plan Req_Land_km2 - The amount of land required (in km-squared) to host the required generating capacity that is capable of meeting the specified capacity factor for the given technology type in the given state and under the given scenario Req_Energy_TWh - Product of Req_Capacity_MW, Req_Capacity_Factor, and 8760/1e6 for the given technology type in the given state and under the given scenario MSI_Case - The level of MSI that siting the given technology is additionally constrained to, where >0 means siting is additionally constrained to suitable land areas that have an MSI value greater than 0 >=1 means siting is additionally constrained to suitable land areas that have an MSI value greater than or equal to 1 >=2 means siting is additionally constrained to suitable land areas that have an MSI value greater than or equal to 2 >=3 means siting is additionally constrained to suitable land areas that have an MSI value greater than or equal to 3 Soil Attribute Rasters Description: This folder contains geospatial raster files for individual soil parameters upscaled to the listed grid resolution (30m or 1 km). 1 km resolution files are a spatial average of non-missing 30m resolution values. All raster files use the USA Contiguous Albers Equal Area Conic (ESRI:102003) projection. Files: avg_cond_raster_ .tif - Average conductivity of the saturation extract across all soil horizons within a depth of 40 inches, measured in mmhos/cm max_cond_raster_ .tif - Maximum conductivity of the saturation extract across all soil horizons within a depth of 40 inches, measured in mmhos/cm min_ph_raster_ .tif- Min pH values across all soil horizons within a depth of 40 inches. avg_ph_raster_ .tif - Average pH value across all soil horizons within a depth of 40 inches. max_ph_raster_ .tif- Max pH value across all soil horizons within a depth of 40 inches. erosion_factor_raster_ .tif - Product of k-factor and percent slope flood_freq_raster_ .tif - Number of months of the year during which the area is commonly, frequently, or very frequently flooded. max_sar_raster_ .tif - Maximum sodium adsorption ratio across all horizons within a depth of 40 inches rock_frac_raster_ .tif - Fraction of the upper 6 inches of soil composed of rock fragments larger than 3 inches. temp_regime_raster_ .tif - Soil temperature regime with the following key: 0 = pergelic 1 = gelic 2 = cryic 3 = frigid 4 = isofrigid 5 = mesic 6 = isomesic 7 = thermic 8 = isothermic 9 = hyperthermic 10 =isohyperthermic Marginal Soils Index Rasters Description: This folder contains geospatial raster files of the Marginal Soils Index at the listed grid resolution (30m or 1 km). 1 km resolution files are a spatial average of 30m resolution. Both raster files use the USA Contiguous Albers Equal Area Conic (ESRI:102003) projection. A value of 0 indicates that there were no soil attributes present that indicate marginal soil. NA values indicate that data was unavailable or bodies of water. Files: marginal_soils_index_30m_raster.tif marginal_soils_index_1km_raster.tif Marginal Soils Index Resource Potential Rasters Description: This folder contains geospatial raster files of the Marginal Soils Index + Resource Potential (MSIxRP) score at 1km resolution for geothermal, solar, and wind technologies. Raster files use the USA Contiguous Albers Equal Area Conic (ESRI:102003) projection. NA values indicate that the location is not suitable for siting the given technology due to policy, environmental, socioeconomic, topological, and other constraints regardless of soil marginality level. Areas with values greater than or equal to zero represent the product of the normalized MSI value and the normalized resource potential value. Files: geothermal_msi_rp_score_raster.tif solar_msi_rp_score_raster.tif wind_msi_rp_score_raster.tif Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Agriculture↗

Marginal Soils Index Analysis & Geospatial Data

This data package contains output files associated with Mongird et al. (in prep) organized into four dataset directories. Each dataset is described in more detail below. 1. Marginal Soils Index Analysis Description: This folder contains a csv file with land needs and availability by state, power generating technology type, and scenario in 2050 when suitable siting areas are additionally constrained to areas with increasing levels of soil marginality. Files: msi_constrained_siting_availability_2050.csv Variables: Scenario - Projected 2050 scenario name State - US state abbreviation Technology - Generating technology type solar = solar photovoltaic gas_cc_re = natural gas combined cycle (recirculating cooling) wind = onshore wind gas_cc_ccs_re = natural gas combined cycle with carbon capture sequestration (recirculating cooling) gas_cc_dry = natural gas combined cycle with (dry cooling) gas_cc_pond = natural gas combined cycle with (pond cooling) coal_conv_ccs_re = conventional coal with carbon capture sequestration (recirculating cooling) Req_Capacity_MW - The amount of rated capacity required in 2050 of the given technology type in the given state and under the given scenario from the capacity expansion plan Req_Capacity_Factor - The assumed capacity factor (fraction between 0 and 1) for the given technology type in the given state and under the given scenario by the capacity expansion plan Req_Land_km2 - The amount of land required (in km-squared) to host the required generating capacity that is capable of meeting the specified capacity factor for the given technology type in the given state and under the given scenario Req_Energy_TWh - Product of Req_Capacity_MW, Req_Capacity_Factor, and 8760/1e6 for the given technology type in the given state and under the given scenario MSI_Case - The level of MSI that siting the given technology is additionally constrained to, where >0 means siting is additionally constrained to suitable land areas that have an MSI value greater than 0 >=1 means siting is additionally constrained to suitable land areas that have an MSI value greater than or equal to 1 >=2 means siting is additionally constrained to suitable land areas that have an MSI value greater than or equal to 2 >=3 means siting is additionally constrained to suitable land areas that have an MSI value greater than or equal to 3 Soil Attribute Rasters Description: This folder contains geospatial raster files for individual soil parameters upscaled to the listed grid resolution (30m or 1 km). 1 km resolution files are a spatial average of non-missing 30m resolution values. All raster files use the USA Contiguous Albers Equal Area Conic (ESRI:102003) projection. Files: avg_cond_raster_ .tif - Average conductivity of the saturation extract across all soil horizons within a depth of 40 inches, measured in mmhos/cm max_cond_raster_ .tif - Maximum conductivity of the saturation extract across all soil horizons within a depth of 40 inches, measured in mmhos/cm min_ph_raster_ .tif- Min pH values across all soil horizons within a depth of 40 inches. avg_ph_raster_ .tif - Average pH value across all soil horizons within a depth of 40 inches. max_ph_raster_ .tif- Max pH value across all soil horizons within a depth of 40 inches. erosion_factor_raster_ .tif - Product of k-factor and percent slope flood_freq_raster_ .tif - Number of months of the year during which the area is commonly, frequently, or very frequently flooded. max_sar_raster_ .tif - Maximum sodium adsorption ratio across all horizons within a depth of 40 inches rock_frac_raster_ .tif - Fraction of the upper 6 inches of soil composed of rock fragments larger than 3 inches. temp_regime_raster_ .tif - Soil temperature regime with the following key: 0 = pergelic 1 = gelic 2 = cryic 3 = frigid 4 = isofrigid 5 = mesic 6 = isomesic 7 = thermic 8 = isothermic 9 = hyperthermic 10 =isohyperthermic Marginal Soils Index Rasters Description: This folder contains geospatial raster files of the Marginal Soils Index at the listed grid resolution (30m or 1 km). 1 km resolution files are a spatial average of 30m resolution. Both raster files use the USA Contiguous Albers Equal Area Conic (ESRI:102003) projection. A value of 0 indicates that there were no soil attributes present that indicate marginal soil. NA values indicate that data was unavailable or bodies of water. Files: marginal_soils_index_30m_raster.tif marginal_soils_index_1km_raster.tif Marginal Soils Index Resource Potential Rasters Description: This folder contains geospatial raster files of the Marginal Soils Index + Resource Potential (MSI+RP) score at 1km resolution for geothermal, solar, and wind technologies. Raster files use the USA Contiguous Albers Equal Area Conic (ESRI:102003) projection. NA values indicate that the location is not suitable for siting the given technology due to policy, environmental, socioeconomic, topological, and other constraints regardless of soil marginality level. Areas with values greater than or equal to zero represent the product of the normalized MSI value and the normalized resource potential value. Files: geothermal_msi_ep_score_raster.tif solar_msi_ep_score_raster.tif wind_msi_ep_score_raster.tif Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Agriculture↗

CERF: IM3 Projected Western US Power Plant Locations

Overview The Capacity Expansion Regional Feasibility (CERF) model is an open-source geospatial python package that provides new power plant locations at a 1km resolution. The model ingests U.S. state or regional-scale electricity system capacity expansion plans, such as those produced by the Global Change Analysis Model (GCAM-USA), and identifies feasible, site-specific locations for individual new power plants (renewable and non-renewable). CERF combines high-resolution geospatial suitability analyses with an economic algorithm that selects individual plant siting locations based on grid interconnection costs and the locational marginal value of new generation. The model incorporates a wide range of dynamic constraints and opportunities, such as protected lands, population density, existing infrastructure, and water availability. This dataset provides CERF power plant siting results for IM3 Phase 2 simulations across eight different scenarios for the Western US through 2055. The scenarios include combinations of two Shared Socioeconomic Pathways (SSP3 and SSP5) with four high-resolution climate projections specific to the United States (see, https://tgw-data.msdlive.org/). These climate projections include "hotter" and "cooler" variants for two Representative Concentration Pathways (RCP4.5 and RCP8.5). The resulting eight simulations are: rcp45cooler_ssp3 rcp45cooler_ssp5 rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85cooler_ssp3 rcp85cooler_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 CERF siting results in this dataset correspond to capacity expansion plans in the GCAM-USA IM3 Phase 2 simulation data and are available for each of the above scenarios. Data Details Temporal Range: 2015-2055 in 5-year timesteps. Note that 2015 is the experiment base year and 2020 and beyond represent model simulation years. Spatial Range: Plant locations are provided for the eleven states in the Western US including Arizona, California, Colorado, Idaho, Montana, New Mexico, Nevada, Oregon, Utah, Washington, and Wyoming. Spatial Resolution: 1 km-squared, provided in x and y coordinates Geospatial Projection: Albers Equal Area Conic (ESRI:102003) File Type: csv The dataset contains subdirectories for each of the eight scenarios described in the overview. Each scenario folder contains two subfolders with the following information: 1. Power Plant Data This directory contains a single .csv file of power plant locations for both pre-existing (non-CERF sited plants in operation in 2015) and new (CERF-sited) power plants across the temporal range along with additional CERF model output parameters for CERF-sited plants. Plant with a siting year earlier than 2020 correspond to facilities that are operational leading into the first timestep CERF simulation. For a more detailed description of CERF model output parameters, see the CERF model documentation. Note that the cerf_plant_id parameter is unique within each scenario file but not across scenario files. Parameter Descriptions scenario - Name of scenario cerf_plant_id - Unique siting identifier cerf_sited - If True, indicates that plant was sited by CERF model. If False, indicates pre-existing facility region_name - Name of region (state) tech_id - Technology ID tech_name - Full generation technology name inclusive of cooling type (if applicable) and additional characteristics tech_simple - Simplified generation technology type unit_size_mw - Power plant unit size (MW) xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) index - Index position in the flattend 2D array buffer_in_km - Exclusion buffer around site (km) sited_year - Year of siting retirement_year - Year of retirement lmp_zone - Locational marginal price (LMP) zone ID locational_marginal_price_usd_per_mwh - Locational marginal price ($/MWh) generation_mwh_per_year - Generation output (MWh/yr) operating_cost_usd_per_year - Cost of plant operations ($/yr) net_operational_value - Net operational value based on LMP and and operating costs ($/yr) interconnection_cost - Cost of interconnection for transmission & gas pipeline (if applicable) net_locational_cost -- Difference of interconnection cost and operating value ($/yr) capacity_factor_fraction - Capacity factor (fraction) carbon_capture_rate_fraction - Carbon capture rate (fraction) fuel_co2_content_tons_per_btu - Fuel CO2 content (tons/Btu) fuel_price_usd_per_mmbtu - Fuel price ($/MMBtu) fuel_price_esc_rate_fraction - Fuel price escalation rate (fraction) heat_rate_btu_per_kWh - Heat rate (Btu/kWh) lifetime_yrs - Technology lifetime for annuity (years) operational_life_yrs - Operational lifetime for retirement (years) variable_om_usd_per_mwh - Variable operation and maintenance costs of yearly capacity use ($/MWh) variable_om_esc_rate_fraction - Variable operation and maintenance costs escalation rate (fraction) carbon_tax_usd_per_ton - Carbon tax ($/ton) carbon_tax_esc_rate_fraction - Carbon tax escalation rate (fraction) 2. Storage Data This directory contains information on new and pre-existing energy storage facilities operational in each timestep along with various storage operational parameters. The 2015 timestep provides pre-existing energy storage data and corresponds with facilities that are operational leading into the first model simulation timestep. Note that coordinates in the storage files correspond to the interconnection point on the grid (substation location), not individual energy storage locations. Energy storage is added in a cumulative process at each given interconnection point. That is, each individual file provides the total operational storage capacity interconnected to the specified substation for the given timestep, inclusive of previously installed storage at that location and new storage installed in that timestep at that location. Parameters scenario - Name of scenario timestep - Simulation timestep name - Unique storage identifier s_typ - Type of energy storage technology (battery or pumped storage hydro) s_node - Node ID of interconnecting substation xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) charge_rate - Maximum charge rate (power capacity) of storage system (MW) discharge_rate - Maximum discharge rate (power capacity) of storage system (MW) duration - Duration of storage system (hours) max_SoC - Allowed maximum state of charge (energy capacity) of storage system (MWh) min_SoC -Allowed minimum state of charge (energy capacity) of storage system (MWh) charge_eff - Efficiency of charge (fraction between 0 and 1) discharge_eff - Efficiency of discharge (fraction between 0 and 1) Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program.

CERF↗

Probing jet base emission of M87* with the 2021 Event Horizon Telescope observations

We investigate the presence and spatial characteristics of the jet base emission in M87* at 230 GHz, enabled by the significantly enhanced (u,v) coverage in the 2021 Event Horizon Telescope (EHT) observations. The integration of the 12−m Kitt Peak Telescope (USA) and NOEMA (France) stations into the array introduces two critical intermediate-length baselines to SMT (USA) and IRAM 30−m (Spain), providing sensitivity to emission structures at spatial scales of ∼250 μas and ∼2500 μas (∼ 0.02 pc and ∼ 0.02 pc). Without these new baselines, previous EHT observations of the source in 2017 and 2018 lacked the capability to constrain emission on large scales, where a “missing flux” of order ∼1 Jy is expected to reside. To probe these scales, we analyzed closure phases–robust against station-based gain calibration errors–and model the jet base emission using a simple Gaussian component offset from the compact ring emission at spatial separations > 100 μas. Our analysis revealed a Gaussian feature centered at (ΔRA ≈ 320 μ as, ΔDec. ≈ 60 μ as), projected separation of ≈ 5500 AU, with an estimated flux density of only ∼60 mJy, implying that most of the missing flux identified in previous EHT studies had to originate from different, larger scales. Brighter emission at the relevant spatial scales is firmly ruled out, and the data do not favor more complex models. This component aligns with the inferred position of the large-scale jet and is therefore physically consistent with the emission of the jet base. While our findings point to detectable jet base emission at 230 GHz, the limited coverage provided by only two intermediate baselines limits our ability to robustly reconstruct its morphology. Consequently, we treated the recovered Gaussian as an upper limit on the jet base flux density. Future EHT observations with expanded intermediate baseline coverage will be essential to constrain the structure and nature of this component with higher precision.

accretion, accretion disks↗

Full-polarization millimeter wavelength variability of Sagittarius A * during the 2018 EHT campaign

Context. Sagittarius A* (Sgr A*), the supermassive black hole at the center of the Milky Way, provides a unique laboratory to study accretion dynamics and plasma processes near the event horizon. Aims. We investigated the variability and polarization properties of Sgr A* using ALMA observations during the 2018 Event Horizon Telescope campaign. Methods. We analyzed high-cadence full-polarization light curves from ALMA at millimeter wavelengths, performed time-series analysis, and investigated the temporal behavior during an X-ray flare observed by Chandra on 2018 April 24. The variability characteristics are compared with expectations from standard accretion flow models. Results. We find low variability in total intensity (σ/μ < 10%), but significantly higher variability in linear and circular polarization (∼30% and ∼50%, respectively). A time-series analysis reveals red-noise variability, with power spectral densities between −2 and −3 across all Stokes parameters. Polarized intensity shows stable intra-day timescales, while total intensity exhibits more variable timescales, suggesting distinct emission regions, with polarization likely arising from a coherent structure. On April 24, a statistically significant inter-band delay in polarized intensity coincides with a near-simultaneous X-ray and millimeter peak that deviates from the typical delayed flare scenario. This event also features enhanced millimeter variability and coherent polarization loop evolution. The observed simultaneity challenges standard models of transient synchrotron emission with cooling delays, favoring instead a scenario of continuous energy injection in an optically thin region. Conclusions. Our results offer new constraints on the physical mechanisms driving variability in Sgr A*, and provide key observational input for refining theoretical models of accretion and plasma behavior in the vicinity of supermassive black holes.

Galaxy: center↗

Spatially resolved polarization swings in the supermassive binary black hole candidate OJ 287 with first Event Horizon Telescope observations

We present the first Event Horizon Telescope 1.3 mm observations of the supermassive binary black hole candidate OJ 287. The observations achieved an unprecedented angular resolution of 18 μas and reveal significant structural and polarization variability over just five days, marking the shortest timescale on which such changes have been directly imaged in this source. The inner jet exhibits a twisted ridgeline structure, with features displaying apparent superluminal motions up to about 22 c. The linear polarization maps reveal three main polarized features whose electric-vector position angles (EVPAs) change substantially over the time span of our observations, including a component with a radial polarization consistent with being produced by a recollimation shock. Most notably, we directly resolved two innermost jet components whose EVPAs rotate in opposite directions. The faster component, moving at 2.4 ± 0.9 μas/day (17.4 ± 6.5 c), exhibits counterclockwise EVPA swings of roughly 3.7° per day, while the slower component, with a proper motion of 1.4 ± 0.3 μas/day (10.2 ± 2.2 c), rotates clockwise at approximately 2.5° per day. Previous studies inferred helical magnetic fields in AGN jets from time-resolved or integrated polarization variability but lacked the angular resolution to directly image this effect. Our results provide spatially resolved evidence that a helical magnetic field threads the jet’s collimation and acceleration zone, ruling out models based on the superposition of unresolved components. Our analysis suggests that propagating shocks interact with a Kelvin–Helmholtz plasma instability, illuminating different phases of the helical magnetic field and producing the observed polarization spatial and temporal variability. Moreover, our model naturally accounts for the more rapid polarization rotation observed in the faster moving component. Our model predicts even more rapid swings in polarization, which could be tested with future observations featuring a more densely sampled time coverage.

OJ 287↗

TRAILS Output Files

Overview This data repository contains ZIP files that store compressed versions of the output of running the WaterPaths utility planning and management tool in the DU Re-Evaluation mode (to download the tool, please see this GitHub repository). The tool was used to simulate the six-utility North Carolina Research Triangle problem. Details on the contents of each ZIP file can be seen below. Data details Temporal range: Weekly data for 2,344 weeks from 2015 to 2060 (45 years). Spatial range: Six water utilities in the North Carolina Research Triangle region (0: Chapel Hil/OWASA, 1: Durham, 2: Cary, 3: Raleigh, 4: Pittsboro, and 5: Chatham) File types: CSV and OUT Different solutions available The solution numbers correspond to the different pathway strategies (henceforth referred to as "solutions") discussed in paper's main and supporting text (abstract and link to the paper here). They are as follows: Sol92: The Durham-focused pathway strategy Sol132: The Raleigh-focused pathway strategy Sol140: The regionally-robust pathway strategy Objectives files These files can be accessed by unzipping solXX_objectives_pathways.zip that contains 1,000 Objectives_RDMXX_solsXX_to_XX.csv files. Each CSV file will consist of a row representing all the objective values for that specific solution, while every six columns represents the reliability, restriction frequency, infrastructure net present value ($ mil), peak financial cost, worst-case cost, and unit cost ($ per MG; in that order) for each of the six utilities. There will be 1,000 such files, denoting the performance of the six utilities across the 1,000 deeply uncertain states of the world (DU SOWs). Pathway files These files can be accessed by unzipping solXX_objectives_pathways.zip that contains 1,000 Pathways_sXX_RDMXX.out file. Each OUT corresponds to the set of infrastructure being triggered in a specific DU SOW, and each file will have the name file will consist of four tab-delimited columns that are described as follows: Realization: The realization in which an infrastructure options being triggered utility: The utility currently triggering infrastructure week: The week in which a specific infrastructure option is being triggered infra.: The infrastructure option being triggered If the OUT file contains only the header line, no infrastructure was triggered for that specific DU SOW. Policies files These files can be obtained by unzipping Policies.zip. Each of the 1,000 CSV files within the unzipped folder will contain weekly water use restriction policies for all 1,000 hydroclimatic realizations within a specific DU SOW. The column structure is as follows: 0rest_m: restriction multiplier for utility 0 (values between 0 and 1) 1rest_m: restriction multiplier for utility 1 (values between 0 and 1) 2rest_m: restriction multiplier for utility 2 (values between 0 and 1) 3rest_m: restriction multiplier for utility 3 (values between 0 and 1) 4rest_m: restriction multiplier for utility 4 (values between 0 and 1) 5rest_m: restriction multiplier for utility 5 (values between 0 and 1) 0transf: transfer volume for utility 0 (in MGD) 1transf: transfer volume for utility 1 (in MGD) 2transf: transfer volume for utility 2 (in MGD) 3transf: transfer volume for utility 3 (in MGD) 4transf: transfer volume for utility 4 (in MGD) 5transf: transfer volume for utility 5 (in MGD) Water Sources files These files can be obtained by unzipping WaterSources_subset.zip. Each of the 100 CSV files within the unzipped folder will contain weekly state variables at each water source for all 1,000 hydroclimatic realizations within a specific DU SOW. The column structure is as follows: Xvolume: available water volume from source X (in MGD) Xs_area: surface area of source X (in ACF) Xdemand: demand drawn from a water source from source X (in MGD) Xup_spill: upstream spillage from source X (in MGD) Xww_inflow: wastewater inflow from source X (in MGD) Xcatch_inflow: upstream catchment inflow to source X (in MGD) Xevap: evaporation multiplier for source X (values between 0 and 1) Xds_spill: downstream spillage from source X (in MGD) X_Y_alloc_cap: the allocated capacity from source X to utility Y (values between 0 and 1) X_Y_alloc_dem: the allocated demand from source X to utility Y (values between 0 and 1) Xtrmt_alloc_Y: the allocated treatment capacity from source X to utility Y (values between 0 and 1) Utilities files These files can be obtained by unzipping Utilities_subset.zip. Each of the 100 CSV files within the unzipped folder will contain weekly state variables at each utility for all 1,000 hydroclimatic realizations within a specific DU SOW. The column structure is as follows: Xst_vol: total available storage volume of utility X (in MG) Xcapacity: total storage capacity of utility X (in MG) Xnet_inf: : net inflow for all storage infrastructure for utility X (in MGD) Xst_rof: short term ROF for utility X (values between 0 and 1) Xst_stor_rof: short-term storage ROF for utility X (values between 0 and 1) Xst_trmt_rof: short-term treatment ROF for utility X (values between 0 and 1) Xlt_rof: long-term ROF for utility X (values between 0 and 1) Xlt_stor_rof: long-term storage ROF for utility X (values between 0 and 1) Xlt_trmt_rof: long-term treatment ROF for utility X (values between 0 and 1) Xrest_demand: restricted demand for utility X (in MGD) Xunrest_demand: unrestricted demand for utility X (in MGD) Xunfulf_demand: unfulfilled demand for utility X (in MGD) Xwastewater: wastewater return for utility X (in MGD) Xtreat_capacity: total treatment capacity for utility X (in MG) Xcont_fund: reserve (contingency) fund balance for utility X Xins_pout: insurance payout for utility X (% annual volumetric revenue) Xins_price: insurance price for utility X (% annual volumetric revenue) Xinfra_npv: infrastructure net present value for utility ($mil) Xst_vol: total available storage volume of utility X (in MG) Xdebt_serv: debt service for utility X (usually once per year if the infrastructure is triggered; % annual volumetric revenue) Xstor_vol: total stored volume (in MGD) Xobs_ann_dem: observed annual demand for utility X (in MGD) Xproj_dem: projected annual demand for utility X (in MGD) Xpv_debt_serv: present value of debt service payments for utility X (% annual volumetric revenue) Xgross_rev: gross revenue for utility X ($mil) Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program.

Artificial Intelligence↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗