Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data Intensive Science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Status of the Mu2e experiment at Fermilab

The Mu2e experiment at Fermilab aims to measure the charged-lepton flavour violating (CLFV) neutrino-less conversion of a negative muon into an electron in the field of a nucleus with an unprecedented single event sensitivity of 3x10^{-17}. This document illustrates the physics motivation and design of the experiment.In the current schedule Mu2e is expected to start taking data in 2025 with a reduced average beam intensity for about two years (Run 1). After a shut down for the upgrade of Fermilab accelerator complex, data taking will restart at full beam intensity (Run 2). A detailed update of the expected experiment sensitivity for Mu2e Run 1 is presented, together with an estimate of the final Mu2e sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron powder diffraction, Mossbauer Spectroscopy and Optical Spectroscopy to study magnetic and nuclear lattices in Fe-based oxychlorides Ca2FeO3Cl, Sr2FeO3Cl and Sr3Fe2O5Cl2

Data for Neutron Diffraction, Mossbauer Spectoscopy and Optical Spectroscopy are contained on all three samples (Ca2FeO3Cl, Sr2FeO3Cl, and Sr3Fe2O5Cl2). Mossbauer data are in the folder "MossbauerSpectroscopy". This contains details of files and examples to read the data. The Optical Spectroscopy are in the folder "AbsorptionData", this contains one file with explanatory headers. The neutron diffraction data are in the "NeutronDiffractionData" folder. The data was collected on the HB-2A powder diffractometer at HFIR. The autoreduced files are corrected using a vanadium standard and are in arbitrary intensity units. The RawData folder contains the uncorrected data with metadata for motor positions and temperature. All measurements were collected with a constant neuton wavelength of 2.41 Angstrom. An excel spreadsheet "NeutronDiffractionData_IPTS-29118_summary" contains details for each scan. Sr3Fe2O5Cl2 data were collected at only room temperature. Ca2FeO3Cl and Sr2FeO3Cl data were collected at 4K and room temperature. The autoreduced .dat fileformat is three columns corresponding to: Two-theta, Intensity and Intensity_error.

fe-based oxychlorides↗

Beam-induced and cosmic-ray backgrounds observed in the ATLAS detector during the LHC 2012 proton-proton running period

This paper discusses various observations on beam-induced and cosmic-ray backgrounds in the ATLAS detector during the LHC 2012 proton-proton run. Building on published results based on 2011 data, the correlations between background and residual pressure of the beam vacuum are revisited. Ghost charge evolution over 2012 and its role for backgrounds are evaluated. New methods to monitor ghost charge with beam-gas rates are presented and observations of LHC abort gap population by ghost charge are discussed in detail. Fake jets from colliding bunches and from ghost charge are analysed with improved methods, showing that ghost charge in individual radio-frequency buckets of the LHC can be resolved. Some results of two short periods of dedicated cosmic-ray background data-taking are shown; in particular cosmic-ray muon induced fake jet rates are compared to Monte Carlo simulations and to the fake jet rates from beam background. A thorough analysis of a particular LHC fill, where abnormally high background was observed, is presented. Correlations between backgrounds and beam intensity losses in special fills with very high β* are studied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Removal of spurious data in Bragg coherent diffraction imaging: an algorithm for automated data preprocessing

Bragg coherent diffraction imaging (BCDI) provides a powerful tool for obtaining high-resolution structural information from nanocrystalline materials. Here a BCDI sample consisting of a large number of randomly oriented nanoscale crystals is considered. Ideally, only one crystal is oriented to produce a Bragg peak on the detector. However, diffraction from other crystals often produces additional signals on the detector. Before the measured diffraction patterns can be processed into structural images, scientists routinely need to manually identify and remove the `alien' intensities from sources other than the intended crystal. With the development of modern high-coherence storage rings, such as the upgraded Advanced Photon Source (APS), the already slow process of manual preprocessing will be untenable for the large volumes of data that will be produced. An automated method of identifying and deleting alien intensities is proposed. This method exploits the fact that BCDI of a perfect crystal produces diffraction data with inversion symmetry around the Bragg peak. This approach uses the machine learning clustering method DBSCAN to distinguish between diffraction from multiple sources, and then calculates cluster size and inversion symmetry to assess whether clusters of intensity belong to desired data or alien signals. This approach can dramatically reduce the amount of time spent manually processing data, allowing BCDI data processing capabilities to keep pace with the technological advances of fourth-generation synchrotron light sources.

36 MATERIALS SCIENCE↗

SU-E-T-771: Two Dimensional Raman Mapping of Carbon Bonds of Radiochromic Films: An Approach to Micro-Dosimetry

Purpose: To study a feasibility of micro-dosimetry with high dose-sensitivity and resolution using two-dimensional Raman mapping on the basis of carbon bonds concentration of radiochromic films Methods: Unlaminated EBT3 films with the purpose of maximal Raman data acquisition were irradiated by 6 MV beam from 5 MU to 1000 MU at the reference condition. Each film was irradiated with shielding material of lead blocking on the half of film as well as the jaw open in half for distinct dose contrast. Raman peaks of 2070 cm-1, 2095 cm-1, and 2115 cm-1 were major subjects to study, which are assumed to be the spectroscopy of carbon triple bonds of monomers, carbon double bonds of polymers, and carbon triple bonds of polymers, respectively. Laser exposure for Raman spectroscopy generated peak’s trend due to polymerization by laser output and this trend was utilized to find out basic peaks related to polymerization process. The relative dose contrast in each one film was detected by Raman spectroscopy with the aid of an auto-scanning stage, comparing the dose contrast between non-irradiated area and irradiated area. Raman spatial resolution was enhanced up to 20 micrometers, assuming the spatial uniformity of radio¬active rod-shaped LiPCDA crystals. An optical scanner with 9600 dpi was used to scan the red-channel intensity to read the dose contrast for 5 MU delivered film. Results: The peak intensity for Raman wavenumber of 2070 cm-1 was used for mapping since it reflected the different peak intensities based on polymerization degree by irradiation. Dose contrast from 1000MU to 5 MU was distinguished by Raman mapping analysis, whereas optical intensity of red-channel didn’t show any difference. Conclusion: In consideration of laser effect, the quantitative analysis based on raw data of Raman mapping could provide more statistically reliable dosimetry than point measurements.

60 APPLIED LIFE SCIENCES↗

A fast-time-response extreme ultraviolet spectrometer for measurement of impurity line emissions in the Experimental Advanced Superconducting Tokamak

A flat-field extreme ultraviolet (EUV) spectrometer working in the 20-500 Å wavelength range with fast time response has been newly developed to measure line emissions from highly ionized tungsten in the Experimental Advanced Superconducting Tokamak (EAST) with a tungsten divertor, while the monitoring of light and medium impurities is also an aim in the present development. A flat-field focal plane for spectral image detection is made by a laminar-type varied-line-spacing concave holographic grating with an angle of incidence of 87°. A back-illuminated charge-coupled device (CCD) with a total size of 26.6 × 6.6 mm{sup 2} and pixel numbers of 1024 × 255 (26 × 26 μm{sup 2}/pixel) is used for recording the focal image of spectral lines. An excellent spectral resolution of Δλ{sub 0} = 3-4 pixels, where Δλ{sub 0} is defined as full width at the foot position of a spectral line, is obtained at the 80-400 Å wavelength range after careful adjustment of the grating and CCD positions. The high signal readout rate of the CCD can improve the temporal resolution of time-resolved spectra when the CCD is operated in the full vertical binning mode. It is usually operated at 5 ms per frame. If the vertical size of the CCD is reduced with a narrow slit, the time response becomes faster. The high-time response in the spectral measurement therefore makes possible a variety of spectroscopic studies, e.g., impurity behavior in long pulse discharges with edge-localized mode bursts. An absolute intensity calibration of the EUV spectrometer is also carried out with a technique using the EUV bremsstrahlung continuum at 20-150 Å for quantitative data analysis. Thus, the high-time resolution tungsten spectra have been successfully observed with good spectral resolution using the present EUV spectrometer system. Typical tungsten spectra in the EUV wavelength range observed from EAST discharges are presented with absolute intensity and spectral identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ALMA SCIENCE VERIFICATION DATA: MILLIMETER CONTINUUM POLARIMETRY OF THE BRIGHT RADIO QUASAR 3C 286

We present full-polarization observations of the compact, steep-spectrum radio quasar 3C 286 made with the Atacama Large Millimeter and Submillimeter Array (ALMA) at 1.3 mm. These are the first full-polarization ALMA observations, which were obtained in the framework of Science Verification. A bright core and a south–west component are detected in the total intensity image, similar to previous centimeter images. Polarized emission is also detected toward both components. The fractional polarization of the core is about 17%; this is higher than the fractional polarization at centimeter wavelengths, suggesting that the magnetic field is even more ordered in the millimeter radio core than it is further downstream in the jet. The observed polarization position angle (or electric vector position angle (EVPA)) in the core is ∼39{sup ◦}, which confirms the trend that the EVPA slowly increases from centimeter to millimeter wavelengths. With the aid of multi-frequency VLBI observations, we argue that this EVPA change is associated with the frequency-dependent core position. We also report a serendipitous detection of a sub-mJy source in the field of view, which is likely to be a submillimeter galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

GOAmazon Thermal Desorption Chemical Ionization Mass Spectrometer

Ion abundance measured by Thermal Desorption Chemical Ionization Mass Spectrometer (using quadrupole mass spectrometer) Data file format: Column 1: date and time (UTC) Column 2: measurement uncertainty (units: integrated ion counts) Column 3: ion intensity (units: integrated ion counts) Column 4: 1 min SO2 mixing ratio in ppb Measurement uncertainty is +/- 0.2 ppb.

54 ENVIRONMENTAL SCIENCES↗

Estimated timescales for wet deposition of organic compounds as a function of Henry's law constants

Atmospheric organic compounds may deposit to Earth's surfaces via dry deposition, driven by concentration gradients, and wet deposition, driven by the scavenging of compounds by precipitation. Their removal by deposition has downstream impacts on concentrations of secondary organic aerosol by removing potential aerosol precursors that would otherwise oxidize to form particulate matter. The impact of deposition processes can consequently be considered as competition between rates of oxidation and deposition, but timescales for deposition are not well constrained. While timescales for dry deposition have been estimated and experimentally validated in the past, understanding of wet deposition of organics is still very limited. In this work, we estimate the wet deposition timescale for gas-phase organic compounds in the atmosphere as a function of Henry's law constants, H, using real-world precipitation frequency and size distributions at five globally-distributed sites. The wet deposition timescale decreases significantly with the increase of H until reaching a stable minimum for compounds with H > 10 5 M per atm. We estimate that the median wet deposition timescale for highly soluble gases is approximately 5 hours during a continuous rain event for all sites. However, median estimated timescales ranged from 80 to 200 hours, depending on location. Timescales are found to depend primarily on the frequency and duration of precipitation events rather than their intensity or size characteristics. Based on these data, we demonstrate that timescales for wet deposition of gases can be estimated at any given location using only basic precipitation information, without detailed or high-precision measurements.

54 ENVIRONMENTAL SCIENCES↗

Robust long-range magnetic correlation across antiphase domain boundaries in Sr 2 CrReO 6

Here, we report a resonant elastic x-ray scattering study of a thin-film sample of Sr 2 CrReO 6 , which has one of the highest ferrimagnetic transition temperatures among ordered double perovskites.We found resonantly enhanced magnetic Bragg peaks at Q = (odd, odd, odd) at both the rhenium L 2 and L 3 edges, which coincide with the structural Bragg peaks of Sr 2 CrReO 6 . By analyzing the widths of these Bragg peaks, we extracted very different structural and magnetic correlation lengths. The former is about 15 nm, while the latter is constrained by the instrumental resolution to be at least 90 nm. We argue that a finite structural correlation length is consistent with the existence of antiphase nanodomains in our sample. On the other hand, a much larger magnetic correlation length indicates that the magnetic correlation extends far beyond the boundaries of individual domains and is consistent with strong antiferromagnetic coupling between different antiphase domains. Last, from the azimuthal dependence of the magnetic intensity, we show that the magnetic moments lie perpendicular to the c axis, which explains the earlier bulk magnetization data.

36 MATERIALS SCIENCE↗

Survey of Deep Learning and Physics-Based Approaches in Computational Wave Imaging

Computational wave imaging (CWI) extracts hidden structure and physical properties of a volume of material by analyzing wave signals that traverse that volume. Applications include seismic exploration of the Earth’s subsurface, acoustic imaging and nondestructive testing (NDT) in material science, and ultrasound computed tomography (USCT) in medicine. Current approaches for solving CWI problems can be divided into two categories: those rooted in traditional physics and those based on deep learning. Physics-based methods stand out for their ability to provide high-resolution and quantitatively accurate estimates of acoustic properties within the medium. However, they can be computationally intensive and are susceptible to ill-posedness and nonconvexity typical of CWI problems. Machine learning (ML)-based computational methods have recently emerged, offering a different perspective to address these challenges. Diverse scientific communities have independently pursued the integration of deep learning in CWI. This review discusses how contemporary scientific ML techniques, and deep neural networks in particular, have been developed to enhance and integrate with traditional physics-based methods for solving CWI problems. We present a structured framework that consolidates existing research spanning multiple domains, including computational imaging, wave physics, and data science. This study concludes with important lessons learned from existing ML-based methods and identifies technical hurdles and emerging trends through a systematic analysis of the extensive literature on this topic.

42 ENGINEERING↗

The Vera C. Rubin Observatory Data Preview 1

We present Rubin Data Preview 1 (DP1), the first data from the National Science Foundation–Department of Energy Vera C. Rubin Observatory, comprising raw and calibrated single-epoch images, coadds, difference images, detection catalogs, and ancillary data products. DP1 is based on 1792 optical–near-infrared exposures acquired over 48 distinct nights by the Rubin Commissioning Camera (LSSTComCam) on the Simonyi Survey Telescope at the Summit Facility on Cerro Pachón, Chile in late 2024. DP1 covers ∼15 deg 2 distributed across seven roughly equal-sized noncontiguous fields, each independently observed in six broad photometric bands, ugrizy. The median FWHM of the point-spread function across all bands is approximately 1"14, with the sharpest images reaching about 0." 58. The 5σ point-source depths for coadded images in the deepest field, the Extended Chandra Deep Field South, are u = 24.55, g = 26.18, r = 25.96, i = 25.71, z = 25.07, and y = 23.1. Other fields are no more than 2.2 mag shallower in any band, where they have nonzero coverage. DP1 contains approximately 2.3 million distinct astrophysical objects, of which 1.6 million are extended in at least one band in coadds, and 431 solar system objects, of which 93 are new discoveries. DP1 is approximately 3.5 TB in size and is available to Vera C. Rubin Observatory data rights holders via the Rubin Science Platform, a cloud-based environment for the analysis of petascale astronomical data. While small compared to future LSST releases, its high quality and diversity of data support a broad range of early science investigations ahead of full operations in 2026.

Ground-based astronomy↗

Improved instrumentation for intensity-, wavelength-, temperature-, and magnetic field-resolved photoconductivity spectroscopy

We report instrumentation for photovoltage and photocurrent spectroscopy over a larger continuous range of wavelengths, temperatures, and applied magnetic fields than other instruments described in the literature: 350 nm≤λ≤1700 nm, 1.8 K≤T≤300 K, and B≤9 T. This instrument uses a modulated monochromated incoherent light source with total power<30 μW in combination with an LED in order to probe selected regions of non-linear responses while maintaining low temperatures and avoiding thermal artifacts. The instrument may also be used to measure a related property, the photomagnetoresistance. We demonstrate the importance of normalizing measured responses for variations in light power and describe a rigorous process for performing these normalizations. We discuss several circuits suited to measuring different types of samples and provide analysis for converting measured values into physically relevant properties. Uniform approaches to measurement of these photoproperties are essential for reliable quantitative comparisons between emerging new materials with energy applications. - Highlights: • A novel instrument for measuring photoconductivity and photocurrents of materials and devices. • Continuous parameter space: 350 nm≤λ≤1700, 1.8 K≤T≤300 K, and B≤9 T. • Methodology for treating non-linear responses and variable lamp intensity. • Mathematical detail for extracting properties of materials from measured values is provided.

36 MATERIALS SCIENCE↗

Workshop on Biological Science Opportunities Provided by the APS Upgrade

Synchrotron-based macromolecular X-ray crystallography (MX) is the primary method for determining the structure of biological molecules including proteins, nucleic acids, complexes, and large assemblies at high resolution (e.g., 95% of all new Protein Data Bank [PDB] deposits in 2017). The Advanced Photon Source (APS), which is the largest and the most productive light source for MX, will be upgraded to a multi-bend achromat lattice (the Advanced Photon Source Upgrade — APS-U) that will deliver the ultimate diffraction-limited X-ray source with radically transformative MX capabilities. The specific advantages of the APS-U X-ray source include (1) increased brightness allowing delivery of intense beams with dimensions of 1-μm or less, resulting in a 100-fold improvement in signal-to-noise, (2) increased brightness at high energy (especially for energies of 12 keV-40 keV commonly used in MX) that can be exploited to reduce primary radiation damage, and (3) low-convergence X-ray beams that will be essential for the study of large macromolecular complexes at high resolution. A workshop on “Biological Science Opportunities Provided by the APS Upgrade” was organized at Argonne National Laboratory on August 18-20, 2018, to discuss the biological science opportunities offered by the unique new capabilities of the APS-U and how the broad structural biology community could best exploit them. The APS-U takes place in a context where advances in X-ray free-electron laser (XFEL) sources and cryo-electron microscopy (cryo-EM) have added to the constellation of techniques and propelled structural biology in new directions. Synergies exist between these different technologies and it is essential to develop enabling technologies that exploit the unique, world-leading, and synergistic characteristics of each light source to boost capabilities for producing leading-edge biological research for U.S. Department of Energy (DOE) missions in energy and environment, and National Institutes of Health (NIH) missions in human health.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emulation of dynamic simulators with application to hydrology

Many simulation-intensive tasks in the applied sciences, such as sensitivity analysis, parameter inference or real time control, are hampered by slow simulators. Emulators provide the opportunity of speeding up simulations at the cost of introducing some inaccuracy. An emulator is a fast approximation to a simulator that interpolates between design input–output pairs of the simulator. Increasing the number of design data sets is a computationally demanding way of improving the accuracy of emulation. We investigate the complementary approach of increasing emulation accuracy by including knowledge about the mechanisms of the simulator into the formulation of the emulator. To approximately reproduce the output of dynamic simulators, we consider emulators that are based on a system of linear, ordinary or partial stochastic differential equations with a noise term formulated as a Gaussian process of the parameters to be emulated. This stochastic model is then conditioned to the design data so that it mimics the behavior of the nonlinear simulator as a function of the parameters. The drift terms of the linear model are designed to provide a simplified description of the simulator as a function of its key parameters so that the required corrections by the conditioned Gaussian process noise are as small as possible. The goal of this paper is to compare the gain in accuracy of these emulators by enlarging the design data set and by varying the degree of simplification of the linear model. We apply this framework to a simulator for the shallow water equations in a channel and compare emulation accuracy for emulators based on different spatial discretization levels of the channel and for a standard non-mechanistic emulator. Our results indicate that we have a large gain in accuracy already when using the simplest mechanistic description by a single linear reservoir to formulate the drift term of the linear model. Adding some more reservoirs does not lead to a significant improvement in accuracy. However, the transition to a spatially continuous linear model leads again to a similarly large gain in accuracy as the transition from the non-mechanistic emulator to that based on one reservoir.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Satellite-Based Estimate of Convective Vertical Velocity and Convective Mass Flux: Global Survey and Comparison with Radar Wind Profiler Observations

Convective vertical velocity (w c ) and convective mass flux (M c ) lie at the heart of GCM cumulus parameterizations, but few observations of these critical parameters are available. In this paper, we develop and evaluate a novel, satellite-based method for estimating profiles of w c and M c . Here, comparisons with collocated ground-based radar wind profiler (RWP) observations show that satellite estimated median w c is slightly greater than the RWP estimates, but they show solid agreement when compared at the 95th percentiles (intense updrafts). RWP-derived and satellite estimated M c are broadly comparable in the lower and middle troposphere, with some differences in the upper troposphere due to differences in convective core sampling. A k-means cluster analysis of multiple years of w c data shows that convective characteristics are distinctly different among extratropical convection, tropical land convection, and tropical oceanic convection. Tropical land convection is significantly more intense and more variable than the oceanic counterpart.

54 ENVIRONMENTAL SCIENCES↗

High-throughput terahertz imaging: progress and challenges

Abstract Many exciting terahertz imaging applications, such as non-destructive evaluation, biomedical diagnosis, and security screening, have been historically limited in practical usage due to the raster-scanning requirement of imaging systems, which impose very low imaging speeds. However, recent advancements in terahertz imaging systems have greatly increased the imaging throughput and brought the promising potential of terahertz radiation from research laboratories closer to real-world applications. Here, we review the development of terahertz imaging technologies from both hardware and computational imaging perspectives. We introduce and compare different types of hardware enabling frequency-domain and time-domain imaging using various thermal, photon, and field image sensor arrays. We discuss how different imaging hardware and computational imaging algorithms provide opportunities for capturing time-of-flight, spectroscopic, phase, and intensity image data at high throughputs. Furthermore, the new prospects and challenges for the development of future high-throughput terahertz imaging systems are briefly introduced.

36 MATERIALS SCIENCE↗

Task I: Dark Matter Search Experiments with Cryogenic Detectors: CDMS-I and CDMS-II Task II: Experimental Study of Neutrino Properties: EXO and KamLAND

Dark Matter Search - During the period of performance, our group continued the search for dark matter in the form of weakly interacting massive particles or WIMPs. As a key member of the CDMS (Cryogenic Dark Matter Search) collaboration, we completed the CDMS II experiment which led the field in sensitivity for more than five years. We fabricated all detectors, and participated in detector testing and verification. In addition, we participated in the construction and operation of the facility at the Soudan Underground Laboratory and played key roles in the data acquisition and analysis. Towards the end of the performance period, we began operating the SuperCDMS Soudan experiment, which consists of 15 advanced Ge (9 kg) detectors. The advanced detector design called iZIP grew out of our earlier DOE Particle Detector R&D program which demonstrated the rejection of surface electrons to levels where they are no longer the dominant source of background. Our group invented this advanced design and these larger detectors were fabricated on the Stanford campus in collaboration with the SLAC CDMS group and the Santa Clara University group. The sensitivity reach is expected to be up to 5 times better than CDMS II after two years of operation. We will check the new limits on WIMPs set by XENON100, and we expect improved sensitivity for light mass WIMPs beyond that of any other existing experiment. Our group includes the Spokesperson for SuperCDMS and continues to make important contributions to improvements in the detector technology which are enabling the very low trigger thresholds used to explore the low mass WIMP region. We are making detailed measurements of the charge transport and trapping within Ge crystals, measuring the diffusive trapping distance of the quasiparticle excitations within the Al phonon collector fins on the detector surface, and we are contributing to the development of much improved detector Monte Carlos which are essential to guide the detector design and optimize the analysis. Neutrino Physics – In the period of performance the neutrino group successfully completed the construction of EXO-200 and commissioned the detector. Science data taking started on Jun 1, 2011. With the discovery of the 2-neutrino double-beta decay in 136-Xe and the first measurement of the 0-neutrino mode resulting in the most stringent limit of Majorana masses, our group continues to be a leading innovator in the field of neutrino physics which is central to DOE-HEP Intensity Frontier program. The phenomenon of neutrino oscillations, in part elucidated by our earlier efforts with the Palo Verde and KamLAND experiments, provides the crucial information that neutrino masses are non-zero and, yet, it contains no information on the value of the neutrino mass scale. In recent times our group has therefore shifted its focus to a high sensitivity 0-neutrino double beta decay program, EXO. The 0-neutrino double beta decay provides the best chance of extending the sensitivity to the neutrino mass scale below 10 meV but, maybe more importantly, it tests the nature of the neutrino wave function, providing the most sensitive probe for Majorana particles and lepton number violation. The EXO program, formulated by our group several years ago, plans to use up to tonnes of the isotope 136-Xe to study the 0-neutrino double beta decay mode. The EXO-200 detector is the first step in this program and it represents the only large US-led and based experiment taking data. The EXO-200 isotope enrichment program broke new grounds for the enterprise of double beta decay. The detector design and material selection program paid off, resulting in a background that is among the very best in the field. The “first light" of EXO-200 was very exciting with the discovery -in the first month of data- of the rarest 2-neutrino double beta decay mode ever observed. The lower limit on the 0-neutrino double beta decay half-life, published in Phys. Rev. Lett. and based on the first 120 days of data is the second best but, when translated into a Majorana mass scale, it is one of the most stringent constraint we have on neutrino masses. Indeed, such a limit was the first result to contradict a claim of discovery in 76-Ge for most nuclear matrix elements calculations. As we continue data taking and plan some modest upgrades to EXO-200 our group is also very active in the design of nEXO, a 5 tonne detector based on the technology demonstrated by EXO-200. Over the years we have made it a tradition to explore the frontier and not to be shy about looking in new directions and re-inventing ourselves to best take advantage of the precious few opportunities provided by Nature. We have also cultivated a number of young people at all levels and, by now, many of the undergraduates, graduate students and postdocs educated by this group have leading positions in academia and industry around the world.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗