Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data fitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Magnetic tunnel junction random number generators applied to dynamically tuned probability trees driven by spin orbit torque

Abstract Perpendicular magnetic tunnel junction (pMTJ)-based true-random number generators (RNGs) can consume orders of magnitude less energy per bit than CMOS pseudo-RNGs. Here, we numerically investigate with a macrospin Landau–Lifshitz-Gilbert equation solver the use of pMTJs driven by spin–orbit torque to directly sample numbers from arbitrary probability distributions with the help of a tunable probability tree. The tree operates by dynamically biasing sequences of pMTJ relaxation events, called ‘coinflips’, via an additional applied spin-transfer-torque current. Specifically, using a single, ideal pMTJ device we successfully draw integer samples on the interval [0, 255] from an exponential distribution based on p -value distribution analysis. In order to investigate device-to-device variations, the thermal stability of the pMTJs are varied based on manufactured device data. It is found that while repeatedly using a varied device inhibits ability to recover the probability distribution, the device variations average out when considering the entire set of devices as a ‘bucket’ to agnostically draw random numbers from. Further, it is noted that the device variations most significantly impact the highest level of the probability tree, with diminishing errors at lower levels. The devices are then used to draw both uniformly and exponentially distributed numbers for the Monte Carlo computation of a problem from particle transport, showing excellent data fit with the analytical solution. Finally, the devices are benchmarked against CMOS and memristor RNGs, showing faster bit generation and significantly lower energy use.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The Atacama Cosmology Telescope: likelihood for small-scale CMB data

The Atacama Cosmology Telescope has measured the angular power spectra of microwave fluctuations to arcminute scales at frequencies of 148 and 218 GHz, from three seasons of data. At small scales the fluctuations in the primordial Cosmic Microwave Background (CMB) become increasingly obscured by extragalactic foregounds and secondary CMB signals. We present results from a nine-parameter model describing these secondary effects, including the thermal and kinematic Sunyaev-Zel'dovich (tSZ and kSZ) power; the clustered and Poisson-like power from Cosmic Infrared Background (CIB) sources, and their frequency scaling; the tSZ-CIB correlation coefficient; the extragalactic radio source power; and thermal dust emission from Galactic cirrus in two different regions of the sky. In order to extract cosmological parameters, we describe a likelihood function for the ACT data, fitting this model to the multi-frequency spectra in the multipole range 500 < l < 10000. We extend the likelihood to include spectra from the South Pole Telescope at frequencies of 95, 150, and 220 GHz. Accounting for different radio source levels and Galactic cirrus emission, the same model provides an excellent fit to both datasets simultaneously, with χ{sup 2}/dof= 675/697 for ACT, and 96/107 for SPT. We then use the multi-frequency likelihood to estimate the CMB power spectrum from ACT in bandpowers, marginalizing over the secondary parameters. This provides a simplified 'CMB-only' likelihood in the range 500 < l < 3500 for use in cosmological parameter estimation.

79 ASTRONOMY AND ASTROPHYSICS↗

Anomalous X-ray galactic signal from 7.1 keV spin-3/2 dark matter decay

In order to explain the recently reported peak at 3.55 keV in the galactic X-ray spectrum, we propose a simple model. In this model, the Standard Model is extended by including a neutral spin-3/2 vector-like fermion that transforms like a singlet under SM gauge group. This 7.1 keV spin-3/2 fermion is considered to comprise a portion of the observed dark matter. Its decay into a neutrino and a photon with decay life commensurate with the observed data, fits the relic dark matter density and obeys the astrophysical constraints from the supernova cooling.

79 ASTRONOMY AND ASTROPHYSICS↗

Error field measurements with rotating RMP fields for DIII-D H-mode

3D magnetic sensors are employed to identify the amplitude and toroidal phase of error fields (EF) by analyzing the torque balance for magnetic islands entrained by rotating resonant magnetic perturbations (RMPs) in DIII-D H-mode plasmas. This technique of torque balance allows for efficient error field identification, offering a valuable tool for scenario-specific and optimized error field compensation (EFC) and requires only magnetic diagnostics. The torque balance used in this work includes the contribution from electromagnetic torque due to error fields, wall response, RMP fields, and viscous. Results show that viscous torque plays a crucial role, particularly during locked modes and H-mode plasmas, ensuring accurate data fits with lower residuals. The torque balance technique reveals that the L- and H-mode plasmas have distinct EF configurations, and consistent with a model-based EF analysis including MHD response in IPEC and the SURFMN EF simulation. This technique shows great robustness in measuring the intrinsic EF amplitude regardless of its amplitude or toroidal phase. Repeated discharges with EFC disparities exhibit consistent results of intrinsic error field within a reasonable range near the “standard” error field compensation. Additionally, the use of a rotating n = 1 resonant magnetic perturbation offers the advantage of reducing disruption risks by entraining saturated magnetic islands. These findings are instrumental for optimizing EF correction in fusion devices, thereby enhancing tearing mode suppression and overall plasma stability.

3D magnetic sensors↗

Fault geometry and slip distribution of the 2008 M w 7.9 Wenchuan, China earthquake, inferred from GPS and InSAR measurements

We revisit the problem of coseismic rupture of the 2008 M w 7.9 Wenchuan earthquake. Precise determination of the fault structure and slip distribution provides critical information about the mechanical behaviour of the fault system and earthquake rupture. We use all the geodetic data available, craft a more realistic Earth structure and fault model compared to previous studies, and employ a nonlinear inversion scheme to optimally solve for the fault geometry and slip distribution. Compared to a homogeneous elastic half-space model and laterally uniform layered models, adopting separate layered elastic structure models on both sides of the Beichuan fault significantly improved data fitting. Our results reveal that: (1) The Beichuan fault is listric in shape, with near surface fault dip angles increasing from ~36° at the southwest end to ~83° at the northeast end of the rupture. (2) The fault rupture style changes from predominantly thrust at the southwest end to dextral at the northeast end of the fault rupture. (3) Fault slip peaks near the surface for most parts of the fault, with~8.4mthrust and ~5 m dextral slip near Hongkou and ~6 m thrust and ~8.4 m dextral slip near Beichuan, respectively. (4) The peak slips are located around fault geometric complexities, suggesting that earthquake style and rupture propagation were determined by fault zone geometric barriers. Such barriers exist primarily along restraining left stepping discontinuities of the dextralcompressional fault system. (5) The seismic moment released on the fault above 20 km depth is 8.2 × 10 21 N m, corresponding to an M w 7.9 event. The seismic moments released on the local slip concentrations are equivalent to events of M w 7.5 at Yingxiu-Hongkou, M w 7.3 at Beichuan-Pingtong, M w 7.2 near Qingping, M w 7.1 near Qingchuan, and M w 6.7 near Nanba, respectively. (6) The fault geometry and kinematics are consistent with a model in which crustal deformation at the eastern margin of the Tibetan plateau is decoupled by differential motion across a decollement in the mid crust, above which deformation is dominated by brittle reverse faulting and below which deformation occurs by viscous horizontal shortening and vertical thickening.

58 GEOSCIENCES↗

Colors of Centaurs observed by the Subaru/Hyper Suprime-Cam and implications for their origin

Abstract Centaurs have orbits between Jupiter and Neptune and are thought to originate from the trans-Neptunian region. Observations of surface properties of Centaurs and comparison with those of trans-Neptunian objects (TNOs) would provide constraints on their origin and evolution. We analyzed imaging data of nine known Centaurs observed by the Hyper Suprime-Cam (HSC) installed on the Subaru Telescope with the g- and i-band filters. Using the data available in the public HSC data archive, as well as those obtained by the HSC Subaru Strategic Program (HSC-SSP) by the end of 2017 June, we obtained the g − i colors of the nine Centaurs. We compared them with those of known TNOs in the HSC-SSP data obtained by T. Terai et al. (2018, PASJ, 70, S40). We found that the color distribution of the nine Centaurs is similar to that of those TNOs with high orbital inclinations, but distinct from those TNOs with low orbital inclinations. We also examined correlations between the colors of these Centaurs and their orbital elements and absolute magnitude. The Centaurs’ colors show a moderate positive correlation with semi-major axis, while no significant correlations between the color and other orbital elements or absolute magnitude were found for these Centaurs. On the other hand, recent studies on Centaurs with larger samples show interesting correlations between their color and absolute magnitude or orbital inclination. We discuss how our data fit in these previous studies, and also discuss implications of these results for their origin and evolution.

Sakugawa, Haruka↗

Numerical calculation of Coulomb corrections in forward elastic 𝑝↑⁢𝑝 and 𝑝↑⁢𝐴 scattering

The analysis of RHIC hydrogen gas jet target polarimeter measurements of transverse analyzing powers 𝐴 N ⁡(𝑡) in proton-nucleus scattering requires accurate Coulomb corrections to both spin-flip and nonflip amplitudes. These corrections must cover a wide range of nuclear charges 𝑍 and form factor slopes, with flexibility to vary form factors during data fitting. To avoid technically challenging calculations involving a small but finite fictitious photon mass, the Coulomb correction to the nonflip electromagnetic amplitude with an exponential form factor was related to the corresponding correction for the spin-flip amplitude. This approach allows soft photon contributions to all amplitudes, including those with nonexponential form factors, to be calculated in the massless photon limit using only analytical expressions and numerically stable integrals with nonsingular integrands and finite integration limits. In addition, an absorptive correction to the spin-flip electromagnetic amplitude, which plays a critical role in spin effects in forward polarized proton-nucleus scattering, was accurately evaluated.

43 PARTICLE ACCELERATORS↗

On Analytics of File Transfer Rates over Dedicated Wide-Area Connections

File transfers between the decentralized storage sites over dedicated wide-area connections are becoming increasingly important in high-performance computing and big data scenarios. Designing such scientific workflows for large file transfers is extremely challenging as they depend on the file, I/O, host, and local- and wide-area network subsystems, and their interactions. To gain insights into file-transfer rate profiles, we develop polynomial, bagging, and boosting regression models for Lustre and XFS file transfer measurements, which are collected using XDD over a suite of 10 Gbps connections with 0-366 ms round trip times (RTTs). In addition to overall trends and analytics, these regressions also provide file-transfer rate estimates for RTTs and number of parallel flows at which measurements might not have been collected. They show that bagging and boosting techniques provide closer data fits than the polynomial regression. We develop probabilistic bounds on the generalization error of these methods, which combined with the cross-validation error establish that former two are more accurate estimators than the polynomial regression. In addition, we present a method to efficiently determine the number of parallel flows to achieve a peak file-transfer rate using fewer than full sweep measurements; in our measurements, the peak is achieved in 96% of cases with 15-25% of measurements of a full sweep.

Sen, Satyabrata↗

Effect of Strain on the Resistivity and Thermal Conductivity of High Purity Niobium

High purity niobium (Nb) is a technologically important material for large-scale accelerator and nano-scale quantum computing applications in microwave frequency range. The high thermal conductivity and low resistivity of Nb are critical to the high performance at temperature range of 0.01–4.0 K. The presence of interstitials such as O, N, H, and C act as scattering centers and alter the mean free path, reducing resistivity and thermal conductivity, and contributing significantly to Nb's thermal performance for temperatures of 2.0 K and above. The residual resistivity ratio (RRR), defined as the ratio of the normal state resistivity at 300 K to that at 4.2 K (Nb, T c = 9.2 K), is an accepted direct estimate of the impurity content of fully recrystallized Nb. Complete re-crystallization of Nb is challenging unless very high temperatures are employed, which is often impractical, hence, in practice, dislocation and dislocation structures impact the thermal performance of Nb due to strong phonon scattering contributions. Furthermore, this paper reports on the degradation of thermal conductivity and RRR of high purity Nb large grain, single crystal with fixed impurity, varying strain, and dislocation content levels. Experimental thermal conductivity data fits the Boltzmann transport equation incorporating dislocation density.

36 MATERIALS SCIENCE↗

Measurement of Dielectric Loss in Silicon Nitride at Centimeter and Millimeter Wavelengths

This work presents a suite of measurement techniques for characterizing the dielectric loss tangent across a wide frequency range from similar to 1 GHz to 150 GHz using the same test chip. In the first method, we fit data from a microwave resonator at different temperatures to a model that captures the two-level system (TLS) response to extract and characterize both the real and imaginary components of the dielectric loss. The inverse of the internal quality factor is a second measure of the overall loss of the resonator, where TLS loss through the dielectric material is typically the dominant source. The third technique is a differential optical measurement at 150 GHz. The same antenna feeds two microstrip lines with different lengths that terminate in two microwave kinetic inductance detectors (MKIDs). The difference in the detector response is used to estimate the loss per unit length of the microstrip line. Our results suggest a larger loss for SiNx at 150 GHz of tan delta similar to 4 x 10(-3) compared to 2.0 x 10(-3) and greater than or similar to 1 x 10(-3) measured at similar to 1 GHz using the other two methods. These measurement techniques can be applied to other dielectrics by adjusting the microstrip lengths to provide enough optical efficiency contrast and other mm/sub-mm frequency ranges by tuning the antenna and feedhorn accordingly.

Dielectrics loss↗

Surface temperature: A key parameter to control the propanethiol plasma polymer chemistry

In this work, the influence of the substrate temperature (T{sub s}) on the chemical composition of propanethiol plasma polymers was investigated for a given set of plasma conditions. In a first study, a decrease in the atomic sulfur content (at. %S) with the deposition time (t{sub d}) was observed. This behavior is explained by the heating of the growing film during deposition process, limiting the incorporation of stable sulfur-based molecules produced in the plasma. Experiments carried out by controlling the substrate temperature support this hypothesis. On the other hand, an empirical law relating the T{sub s} and the at. %S was established. This allows for the formation of gradient layer presenting a heterogeneous chemical composition along the thickness, as determined by depth profile analysis combining X-ray photoelectron spectroscopy and C{sub 60} ion gun sputtering. The experimental data fit with the one predicted from our empiric description. The whole set of our results provide new insights in the relationship between the substrate temperature and the sulfur content in sulfur-based plasma polymers, essential for future developments.

36 MATERIALS SCIENCE↗

SU-E-T-678: Response Calibration Using Electron Depth-Dose Data for MRI-Based 3D Polymer Gel Dosimetry

Purpose: To evaluate a calibration method using the depth-dose data of an electron beam for MRI-based polymer gel dosimetry. Methods: MAGAT was manufactured in-house to fill two 400mL-cylindrical phantoms and nine 22mL-glass vials. Phantom-A was irradiated along the cylinder axis with a 9MeV electron beam of 6 cm x 6 cm field size (FS). Phantom-B was irradiated with a 6MV photon beam of 3 cm x 3 cm FS by a 360-degree arc technique. Eight vials were irradiated in a water-bath to various doses with a 20 cm x 20 cm FS 6MV photon beam. All irradiated phantoms and one un-irradiated vial were scanned with a 3T MRI scanner to obtain the spin-spin relaxation rate (R2) distributions. By comparing the measured R2-to-depth data with the known depth-dose data for Phantom-A, R2-to-dose calibration data were obtained (e-beam method). Another calibration data were obtained from the 9 vials data (9-vial method). We tested two regression equations, i.e., third-order polynomial and tangent functions, and two dose normalization methods, i.e., one-point and two-point methods. Then, these two calibration methods were used to obtain the 3D dose distribution of Phantom-B and evaluated by comparing the measured data with the dose distribution from a treatment planning system. The comparison was made with gamma passing rate (2%/2mm criteria). Results: We did not observe a clear advantage of the e-beam method over the 9-vial method for the 3D dose comparison with the test case. Nevertheless, we found that the e-beam method required a smaller dose scaling for the dose comparison. Furthermore, the tangent function showed better data fitting than the polynomial function with smaller uncertainty of the estimated coefficients. Conclusions: Considering the overall superior performance, we recommend the e-beam method with the tangent function as the regression equation and one-point dose normalization for the MRI-based polymer gel dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-CAMPUS-I-01: Head and Neck Squamous Cell Carcinoma: Short-Term Repeatability of Apparent Diffusion Coefficient and Intravoxel Incoherent Motion Parameters at 3.0T

Purpose: Many published studies have recently demonstrated the potential value of intravoxel incoherent motion (IVIM) analysis for disease evaluation. However, few have questioned its measurement repeatability/reproducibility when applied. The purpose of this study was to determine the short-term measurement repeatability of apparent diffusion coefficient ADC, true diffusion coefficient D, pseudodiffusion coefficient D* and perfusion fraction f, in head and neck squamous cell carcinoma (HNSCC) primary tumors and metastatic nodes. Methods: Ten patients with known HNSCC were examined twice using echo-planar DW-MRI with 12 b values (0 to 800 s/mm2) 1hour to 24 hours apart before radiation treatment. All patients were scanned with the customized radiation treatment immobilization devices to reduce motion artifacts and to improve image registration in repeat scans. Regions of interests were drawn in primary tumor and metastases node in each patient (Fig. 1). ADC and IVIM parameters D, D* and f were calculated by least squares data fitting. Short-term test–retest repeatability of ADC and IVIM parameters were assessed by measuring Bland–Altman limits of agreements (BA-LA). Results: Sixteen HNSCC lesions were assessed in 10 patients. Repeatability of perfusion-sensitive parameters, D* and f, in HNSCC lesions was poor (BA-LA: -144% to 88% and −57% to 96% for D* and f, respectively); a lesser extent was observed for the diffusion-sensitive parameters of ADC and D (BA-LA: −34% to 39% and −37% to 40%, for ADC and D, respectively) (Fig. 2). Conclusion: Poor repeatability of D*/f and good repeatability for ADC/D were observed in HNSCC primary tumors and metastatic nodes. Efforts should be made to improve the measurement repeatability of perfusion-sensitive IVIM parameters.

60 APPLIED LIFE SCIENCES↗

Sci-Thur AM: YIS – 04: Stopping power-to-Cherenkov power ratios and beam quality specification for clinical Cherenkov emission dosimetry of electrons: beam-specific effects and experimental validation

Purpose: To advance towards clinical Cherenkov emission (CE)-based dosimetry by investigating beam-specific effects on Monte Carlo-calculated electron-beam stopping power-to-CE power ratios (SCRs), addressing electron beam quality specification in terms of CE, and validating simulations with measurements. Methods: The EGSnrc user code SPRRZnrc, used to calculate Spencer-Attix stopping-power ratios, was modified to instead calculate SCRs. SCRs were calculated for 6- to 22-MeV clinical electron beams from Varian TrueBeam, Clinac 21EX, and Clinac 2100C/D accelerators. Experiments were performed with a 20-MeV electron beam from a Varian TrueBeam accelerator, using a diffraction grating spectrometer with optical fiber input and a cooled back-illuminated CCD. A fluorophore was dissolved in the water to remove CE signal anisotropy. Results: It was found that angular spread of the incident beam has little effect on the SCR (≤ 0.3% at d{sub max}), while both the electron spectrum and photon contamination increase the SCR at shallow depths and decrease it at large depths. A universal data fit of R{sub 50} in terms of C{sub 50} (50% CE depth) revealed a strong linear dependence (R{sup 2} > 0.9999). The SCR was fit with a Burns-type equation (R{sup 2} = 0.9974, NRMSD = 0.5%). Below-threshold incident radiation was found to have minimal effect on beam quality specification (< 0.1%). Experiments and simulations were in good agreement. Conclusions: Our findings confirm the feasibility of the proposed CE dosimetry method, contingent on computation of SCRs from additional accelerators and on further experimental validation. This work constitutes an important step towards clinical high-resolution out-of-beam CE dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining Roles of Accessory Genes in Denitrification by Mutant Fitness Analyses

Enzymes of the denitrification pathway play an important role in the global nitrogen cycle, including release of nitrous oxide, an ozone-depleting greenhouse gas. In addition, nitric oxide reductase, maturation factors, and proteins associated with nitric oxide detoxification are used by pathogens to combat nitric oxide release by host immune systems. While the core reductases that catalyze the conversion of nitrate to dinitrogen are well understood at a mechanistic level, there are many peripheral proteins required for denitrification whose basic function is unclear. A bar-coded transposon DNA library from Pseudomonas stutzeri strain RCH2 was grown under denitrifying conditions, using nitrate or nitrite as an electron acceptor, and also under molybdenum limitation conditions, with nitrate as the electron acceptor. Analysis of sequencing results from these growths yielded gene fitness data for 3,307 of the 4,265 protein-encoding genes present in strain RCH2. The insights presented here contribute to our understanding of how peripheral proteins contribute to a fully functioning denitrification pathway. We propose a new low-affinity molybdate transporter, OatABC, and show that differential regulation is observed for two MoaA homologs involved in molybdenum cofactor biosynthesis. We also propose that NnrS may function as a membrane-bound NO sensor. Finally, the dominant HemN paralog involved in heme biosynthesis is identified, and a CheR homolog is proposed to function in nitrate chemotaxis. In addition, new insights are provided into nitrite reductase redundancy, nitric oxide reductase maturation, nitrous oxide reductase maturation, and regulation.

59 BASIC BIOLOGICAL SCIENCES↗

Survey of Multifidelity Methods in Uncertainty Propagation, Inference, and Optimization

In many situations across computational science and engineering, multiple computational models are available that describe a system of interest. These different models have varying evaluation costs and varying fidelities. Typically, a computationally expensive high-fidelity model describes the system with the accuracy required by the current application at hand, while lower-fidelity models are less accurate but computationally cheaper than the high-fidelity model. Outer-loop applications, such as optimization, inference, and uncertainty quantification, require multiple model evaluations at many different inputs, which often leads to computational demands that exceed available resources if only the high-fidelity model is used. This work surveys multifidelity methods that accelerate the solution of outer-loop applications by combining high-fidelity and low-fidelity model evaluations, where the low-fidelity evaluations arise from an explicit low-fidelity model (e.g., a simplified physics approximation, a reduced model, a data-fit surrogate) that approximates the same output quantity as the high-fidelity model. The overall premise of these multifidelity methods is that low-fidelity models are leveraged for speedup while the high-fidelity model is kept in the loop to establish accuracy and/or convergence guarantees. We categorize multifidelity methods according to three classes of strategies: adaptation, fusion, and filtering. The paper reviews multifidelity methods in the outer-loop contexts of uncertainty propagation, inference, and optimization.

97 MATHEMATICS AND COMPUTING↗

Modified dark matter: Relating dark energy, dark matter and baryonic matter

Modified dark matter (MDM) is a phenomenological model of dark matter, inspired by gravitational thermodynamics. For an accelerating universe with positive cosmological constant (Λ), such phenomenological considerations lead to the emergence of a critical acceleration parameter related to Λ. Such a critical acceleration is an effective phenomenological manifestation of MDM, and it is found in correlations between dark matter and baryonic matter in galaxy rotation curves. Here, the resulting MDM mass profiles, which are sensitive to Λ, are consistent with observational data at both the galactic and cluster scales. In particular, the same critical acceleration appears both in the galactic and cluster data fits based on MDM. Furthermore, using some robust qualitative arguments, MDM appears to work well on cosmological scales, even though quantitative studies are still lacking. Finally, we comment on certain nonlocal aspects of the quanta of modified dark matter, which may lead to novel nonparticle phenomenology and which may explain why, so far, dark matter detection experiments have failed to detect dark matter particles.

79 ASTRONOMY AND ASTROPHYSICS↗