Toward Large Field-Of-View High-Resolution X-Ray Imaging Spectrometers: Microwave Multiplexed Readout of 28 TES Microcalorimeters
We performed small-scale demonstrations at GSFC of high-resolution Xray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space-based X-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 55mKstage of our laboratory ADR. Using aROACH2 FPGA at room temperature, we read out pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to rf-SQUIDs. The resonators are spaced 6 MHz apart (at ∼ 5.9 GHz) and have quality factors of ∼ 15,000. In our initial demonstration, we used flux-ramp modulation frequencies of 125 kHz to read out 5 pixels simultaneously and achieved spectral resolutions of 2.8-3.1 eV FWHM at 5.9 keV. Our subsequent work is ongoing: to-date we have achieved a median spectral resolution of 3.4 eV FWHM at 5.9 keV while reading out 28 pixels simultaneously with flux-ramp frequencies of 160 kHz. We present the measured system-level noise and maximum slew rates and briefly describe our future development work.
Development of a phoswich detector system for radioxenon monitoring
Abstract Measurement of radioactive xenon in the atmosphere is one of several techniques to detect nuclear weapons testing. For high sensitivity, some existing systems use beta/gamma coincidence detection to suppress background, which is very effective, but increases complexity due to separate beta and gamma detectors that require careful calibration and gain matching. In this paper, we will describe the development and evaluation of a simpler detector system, named PhosWatch, consisting of a CsI(Tl)/ BC-404 phoswich well detector, digital readout electronics, and pulse shape analysis algorithms implemented in a digital signal processor on the electronics, and compare its performance to existing multi-detector systems.
LArPix: demonstration of low-power 3D pixelated charge readout for liquid argon time projection chambers
In this work, we report the demonstration of a low-power pixelated readout system designed for three-dimensional ionization charge detection and digital readout of liquid argon time projection chambers (LArTPCs) . Unambiguous 3D charge readout was achieved using a custom-designed system-on-a-chip ASIC (LArPix) to uniquely instrument each pad in a pixelated array of charge-collection pads. The LArPix ASIC, manufactured in 180 nm bulk CMOS, provides 32 channels of charge-sensitive amplification with self-triggered digitization and multiplexed readout at temperatures from 80 K to 300 K . Using an 832-channel LArPix-based readout system with 3 mm spacing between pads, we demonstrated low-noise (0<50 e - RMS equivalent noise charge) and very low-power (<100 μW/channel) ionization signal detection and readout . The readout was used to successfully measure the three-dimensional ionization distributions of cosmic rays passing through a LArTPC, free from the ambiguities of existing projective techniques. The system design relies on standard printed circuit board manufacturing techniques, enabling scalable and low-cost production of large-area readout systems using common commercial facilities. This demonstration overcomes a critical technical obstacle for operation of LArTPCs in high-occupancy environments, such as the near detector site of the Deep Underground Neutrino Experiment (DUNE) .
Development of a proton Computed Tomography Detector System
Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantegeous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector.
The upgrade of the CMS hadron calorimeter with silicon photomultipliers
The upgrade of the hadron calorimeter of the CMS experiment at the CERN Large Hadron Collider is currently underway. The endcap sections will be upgraded in the winter of 2016–2017 and the barrel sections during the second LHC long shutdown in 2019. The existing photosensors will be replaced with about 16 000 new silicon photomultipliers (SiPMs), resulting in the first large installation of SiPMs in a radiation environment. All associated front-end electronics will also be upgraded. Here, this paper discusses the motivation for the upgrade and provides a description 17 of the new system, including the SiPMs with associated control electronics and the front-end readout cards.
Design, upgrade and characterization of the silicon photomultiplier front-end for the AMIGA detector at the Pierre Auger Observatory
AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to complement the study of ultra-high-energy cosmic rays (UHECR) by measuring the muon content of extensive air showers (EAS). It consists of an array of 61 water Cherenkov detectors on a denser spacing in combination with underground scintillation detectors used for muon density measurement. Each detector is composed of three scintillation modules, with 10 m 2 detection area per module, buried at 2.3 m depth, resulting in a total detection area of 30 m 2 . Silicon photomultiplier sensors (SiPM) measure the amount of scintillation light generated by charged particles traversing the modules. In this paper, the design of the front-end electronics to process the signals of those SiPMs and test results from the laboratory and from the Pierre Auger Observatory are described. Compared to our previous prototype, the new electronics shows a higher performance, higher efficiency and lower power consumption, and it has a new acquisition system with increased dynamic range that allows measurements closer to the shower core. The new acquisition system is based on the measurement of the total charge signal that the muonic component of the cosmic ray shower generates in the detector.
Recent Advances in GaAs JFETs for Deep Cryogenic Focal Plane Readouts
The progress of Jet Propulsion Laboratory in developing gallium arsenide junction field-effect transistors (GaAs JFETs) for application in infrared readout electronics operating below 10 Kelvin is discussed.
Beam test measurements with planar and 3D silicon strip detectors irradiated to sLHC fluences
The planned luminosity upgrade of the CERN LHC to the super LHC (sLHC) requires investigation of new radiation hard tracking detectors. Compared to the LHC, tracking detectors must withstand a 5-10 times higher radiation fluence. Promising radiation hard options are planar silicon detectors with n-side readout and silicon detectors in 3D technology, where columnar electrodes are etched into the silicon substrate. This article presents beam test measurements per formed with planar and 3D n-in-p silicon strip detectors. The detectors were irradiated to different fluences, where the maximum fluence was 3 x 10{sup 15} 1 MeV neutron equivalent particles per square centimeter (n{sub eq}/cm{sup 2}) for the planar detectors and 2 x 10{sup 15} n{sub eq}/cm{sup 2} for the 3D detectors. In addition to signal measurements, charge sharing and resolution of both detector technologies are compared. An increased signal from the irradiated 3D detectors at high bias voltages compared to the signal from the unirradiated detector indicates that charge multiplication effects occur in the 3D detectors. At a bias voltage of 260 V, the 3D detector irradiated to 2 x 10{sup 15} n{sub eq}/cm{sup 2} yields a signal almost twice as high as the signal of the unirradiated detector. Only 30% of the signal of an unirradiated detector could be measured with the planar detector irradiated to 3 x 10{sup 15} n{sub eq}/cm{sup 2} at a bias voltage of 600 V, which was the highest bias voltage applied to this sensor.
Development of a Cryogen-Free Continuous ADR for the Constellation-X Mission
Constellation-X is a multi-satellite x-ray astronomy mission presently being planned for launch in the 2010 time frame. Each of 4 identical satellites will contain a telescope and instruments for imaging and spectroscopic analysis of both hard and soft x-rays. The X- ray Microcalorimeter Spectrometer (XMS) instrument will use arrays of microcalorimeters to detect X-rays with energies from 0.2 to 6 keV. The technologies under development for this instrument include Transition-Edge Sensors (TES) with multiplexed SQUID readouts and NTD-Ge detectors with JFET readouts. Both will be operated at temperatures in the 50-60 mK range and both have a projected cooling power requirement of approximately 5 microwatts. In addition, in order to meet the lifetime requirement of 6 years (with a goal of 10 years), a mechanical cryocooler will be used to provide a heat sink for the low temperature cooler. The required performance is 20 mW at 6 K, with a goal of 4 K operation. In this paper we present the development status of an adiabatic demagnetization refigerator (ADR) that meets the cooling requirements of the X M S instrument. At present we have demonstrated a 4-stage ADR that operates continuously at 50 mK using a 4.2 K helium bath as a heat sink. The cooling power is 21 microwatts at 100 mK and 6 microwatts at 50 mK. Its efficiency when operating at 50 mK is 1 1 % of Carnot (accounting for all dissipation at 4.2 K and below, but not including power dissipation in the room temperature electronics), but this is expected to rise to 25% in the next generation system in which active gas-gap heat switches are replaced with passive devices. This will reduce the peak heat rejection rate of the ADR to less than 7 mW at 6 K. Details of the ADR s design and operation, as well as the development program leading up to a flight-qualified instrument, will be discussed.
Design Studies for a TPC Readout Plane Using Zigzag Patterns With Multistage GEM Detectors
Here, new design studies have been carried out for a readout plane for gas electron multiplier detectors using zigzag patterns that can significantly reduce the readout channel count while preserving excellent spatial resolution for tracking detectors. While zigzag patterns have been used in a number of applications, these studies were designed to investigate the fundamental limits of charge sharing between the electrodes to optimize the spatial resolution and minimize the nonuniformities across the readout plane, while exploring the limits of manufacturing capabilities for producing the readout board. Simulation studies were carried out to optimize the readout electrode structure, and readout boards were produced with similar zigzag designs that were tested in the laboratory using a scanning X-ray source. These studies were aimed at developing a readout board for the new time projection chamber for the sPHENIX experiment at relativistic heavy ion collider, but can readily be used in other applications, including various micropattern gas detectors, such as Micromegas.
Charge readout electronics for the DUNE horizontal drift far detector: design and performance in ProtoDUNE-HD
DUNE (Deep Underground Neutrino Experiment) is a long-baseline neutrino oscillation experiment currently under construction, whose far detectors will be the largest liquid argon time projection chambers ever built. This detector design calls for custom-built cryogenic front-end electronics to meet its performance requirements. This paper describes the charge readout electronics that will be used in the DUNE horizontal drift (HD) far detector and presents performance results using data from the ProtoDUNE-HD detector, a 770 ton liquid argon time projection chamber operated at the CERN Neutrino Platform in 2024 that served as the final prototype of the DUNE HD design.
Proceedings of the Third Infrared Detector Technology Workshop
This volume consists of 37 papers which summarize results presented at the Third Infrared Detector Technology Workshop, held February 7-9, 1989, at Ames Research Center. The workshop focused on infrared (IR) detector, detector array, and cryogenic electronic technologies relevant to low-background space astronomy. Papers on discrete IR detectors, cryogenic readouts, extrinsic and intrinsic IR arrays, and recent results from ground-based observations with integrated arrays were given. Recent developments in the second-generation Hubble Space Telescope (HST) infrared spectrometer and in detectors and arrays for the European Space Agency's Infrared Space Observatory (ISO) are also included, as are status reports on the Space Infrared Telescope Facility (SIRTF) and the Stratospheric Observatory for Infrared Astronomy (SOFIA) projects.
RADIOXENON MEASUREMENTS WITH THE PHOSWATCH DETECTOR SYSTEM
Many of the radioxenon detector systems used in the International Monitoring System and in other applications employ beta/gamma coincidence detection to achieve high sensitivity. In these systems, the coincidence detection is implemented by requiring simultaneous signals from separate beta and gamma detectors. While very sensitive to small amounts of radioxenon, this approach requires careful calibration and gain matching of several detectors and photomultiplier tubes. An alternative approach is the use of a phoswich detector in which beta-gamma coincidences are detected by pulse shape analysis. The phoswich requires only a single photomultiplier tube and thus is easier to set up and calibrate, and can be assembled into a more compact and robust system. In the past, we have developed a COTS detector system, named PhosWatch, which consists of a CsI(Tl)/BC-404 phoswich detector, digital readout electronics, and on-board software to perform the pulse shape analysis. Several units of this system have been manufactured and are now evaluated at several radioxenon research laboratories. In this paper, we will report results from production tests and some of the evaluations, including a side-by-side comparison of a SAUNA detector and a PhosWatch system using atmospheric radioxenon samples. In addition, we will show initial results obtained with a higher speed version of the readout electronics, digitizing at 500 MHz and thus able to better resolve the fast pulses from the BC-404.
ETROC1: the first full chain precision timing prototype ASIC for CMS MTD endcap timing layer upgrade
We present the design and characterization of the first fullchain precision timing prototype ASIC, named ETL Readout Chipversion 1 (ETROC1) for the CMS MTD endcap timing layer (ETL)upgrade. The ETL utilizes Low Gain Avalanche Diode (LGAD) sensors todetect charged particles, with the goal to achieve a time resolutionof 40–50 ps per hit, and 30–40 ps per track with hits from twodetector layers. The ETROC1 is composed of a 5 × 5 pixelarray and peripheral circuits. The pixel array includes a4 × 4 active pixel array with an H-tree shaped networkdelivering clock and charge injection signals. Each active pixel iscomposed of various components, including a bump pad, a chargeinjection circuit, a pre-amplifier, a discriminator, adigital-to-analog converter, and a time-to-digital converter. Thesecomponents play essential roles as the front-end link in processingLGAD signals and measuring timing-related information. Theperipheral circuits provide clock signals and readoutfunctionalities. The size of the ETROC1 chip is7 mm× 9 mm. ETROC1 has been fabricated in a 65 nmCMOS process, and extensively tested under stimuli of chargeinjection, infrared laser, and proton beam. The time resolution ofbump-bonded ETROC1 + LGAD chipsets reaches 42–46 ps per hit in thebeam test.
Pixelated CZT Technology for the Detection, Identification, and Localization of Gamma-Ray Sources - 18311
Radioactive waste-management applications require good measurements to qualitatively and quantitatively characterize waste materials. Often these measurements must be done in situ, and the user wishes to learn something of the isotopic and spatial distribution of the source. Therefore, there is a need for a portable instrument that can map radioactive contamination and quantify sources. This presentation introduces several instruments that have been applied to this task, along with example measurements in relevant applications. All instruments are based on 3D-position-sensitive CdZnTe (CZT) detectors. This technology routinely achieves better than 1.1% FWHM energy resolution at 662 keV and operates at room temperature with a startup time under 2 minutes. All are packaged in portable enclosures with WiFi and Bluetooth capabilities for wireless communication. These capabilities allow the technology to be used in more advanced measurements in the field. A unique capability of these detectors is the ability to image the spatial distribution of gamma rays from a single stationary measurement. The first product, Polaris-H, has been in use at commercial nuclear power plants since 2013. The system, currently used at over 50% of the US nuclear-power fleet, integrates a 3D-position-sensitive CZT detector, associated readout electronics, an embedded computer, a battery with over 7-hour life, an optical camera, and a laser range finder in a portable water-proof enclosure. The system connects wirelessly to a tablet which displays a gamma-ray spectrum and isotope-specific images of the gamma-ray distribution in all directions in real time. The CZT detectors have a dynamic range from 50 keV up to 3 MeV. Coded aperture or pinhole imaging is used for energies below 250 keV, and Compton imaging is used for energies above 250 keV. List-mode data is saved to an external USB memory stick to enable more advanced analysis, including isotopic activity analysis, via H3D's post-processing software. Additional systems based on the same architecture have been developed to optimize the technology for other applications. These include Polaris-H Quad, which provides over 3 times the sensitivity for applications involving weaker sources, and Polaris-H Shield, which uses a collimator to provide images and isotope information over a narrower field of view in order to measure weaker sources in the presence of stronger sources of the same isotope. H3D has also developed custom systems that have been mounted on robots and drones that enable remote operation of the technology. Results from the measurements collected at commercial nuclear power plants and other applicable sites will be presented to show how these instruments can be used to detect, identify, and localize gamma-ray sources. Advanced analysis techniques to show the accurate quantification of the gamma-ray source will also be presented. Applications range from characterizing simple objects, to locating hottest points, estimating contamination distributions on an isotope-by-isotope basis, and differentiating scatter and direct emissions. (authors)
The LiteBIRD Satellite Mission: Sub-Kelvin Instrument
Inflation is the leading theory of the first instant of the universe. Inflation, which postulates that the universe underwent a period of rapid expansion an instant after its birth, provides convincing explanation for cosmological observations. Recent advancements in detector technology have opened opportunities to explore primordial gravitational waves generated by the inflation through “B-mode” (divergent-free) polarization pattern embedded in the cosmic microwave background anisotropies. If detected, these signals would provide strong evidence for inflation, point to the correct model for inflation, and open a window to physics at ultra-high energies. LiteBIRD is a satellite mission with a goal of detecting degree-and-larger-angular-scale B-mode polarization. LiteBIRD will observe at the second Lagrange point with a 400 mm diameter telescope and 2622 detectors. It will survey the entire sky with 15 frequency bands from 40 to 400 GHz to measure and subtract foregrounds. The US LiteBIRD team is proposing to deliver sub-Kelvin instruments that include detectors and readout electronics. A lenslet-coupled sinuous antenna array will cover low-frequency bands (40–235 GHz) with four frequency arrangements of trichroic pixels. An orthomode-transducer-coupled corrugated horn array will cover high-frequency bands (280–402 GHz) with three types of single frequency detectors. The detectors will be made with transition edge sensor (TES) bolometers cooled to a 100 milli-Kelvin base temperature by an adiabatic demagnetization refrigerator. The TES bolometers will be read out using digital frequency multiplexing with Superconducting QUantum Interference Device (SQUID) amplifiers. Up to 78 bolometers will be multiplexed with a single SQUID amplifier. Lastly, we report on the sub-Kelvin instrument design and ongoing developments for the LiteBIRD mission.
Probing macroscopic quantum states with a sub-Heisenberg accuracy
Significant achievements in high-sensitivity measurements will soon allow us to probe quantum behaviors of macroscopic mechanical oscillators. In a recent work [Phys. Rev. A 80, 043802 (2009)], we formulated a general framework for treating preparation of Gaussian quantum states of macroscopic oscillators through linear position measurements. To outline a complete procedure for testing macroscopic quantum mechanics, here we consider a subsequent verification stage which probes the prepared macroscopic quantum state and verifies the quantum dynamics. By adopting an optimal time-dependent homodyne detection in which the phase of the local oscillator varies in time, the conditional quantum state can be characterized below the Heisenberg limit, thereby achieving a quantum tomography. In the limiting case of no readout loss, such a scheme evades measurement-induced back action, which is identical to the variational-type measurement scheme invented by Vyatchanin et al. [JETP 77, 218 (1993)] but in the context for detecting gravitational waves. To motivate macroscopic quantum mechanics experiments with future gravitational-wave detectors, we mostly focus on the parameter regime where the characteristic measurement frequency is much higher than the oscillator frequency and the classical noises are Markovian, which captures the main feature of a broadband gravitational-wave detector. In addition, we discuss verifications of Einstein-Podolsky-Rosen-type entanglement between macroscopic test masses in future gravitational-wave detectors, which enables us to test one particular version of gravity decoherence conjectured by Diosi [Phys. Lett. A120, 377 (1987)] and Penrose [Gen. Rel. Grav. 28, 581 (1996)].