Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Technology Development Plan for the Baseline Detector System of the X-Ray Microcalorimeter Spectrometer (XMS) of the International X-Ray Observatory (IXO)

The primary purpose of this document is to present the technology development plan for the XMS detector system. It covers the current status (including assessment of the Technology Readiness Level, TRL, and a justification of the level assigned), the roadmap to progress to a level between TRL 5 and TRL 6 by the middle of 2012, and an assessment of the associated cost. A secondary purpose of this document is to address the Action Items raised at the XMS Phase-A Study Mid-Term Review that pertain to the detector system (AI #4, #8, and #9).

Kilbourne, C. A.↗

Development of Transition Edge Sensor Detectors Optimized for Single-Photon Spectroscopy in the Optical and Near-Infrared

The search for biosignatures in the atmospheres of exoplanets will be a key focus of future space telescopes that operate in the ultraviolet, visible, and near-infrared bands. Detection of biosignatures requires an instrument with moderate spectral resolving power ($R \sim 100$) and a large bandwidth ($\sim 400$ nm -- $\sim 1.8$ $\mu$m). Additionally, biosignature detection is a photon-starved science; instruments designed for these measurements would ideally combine high optical efficiency with quantum-limited photon detectors (i.e., detectors that exhibit zero dark current). In this work, we report on our efforts to develop energy resolving transition edge sensor (TES)-based detectors designed for biosignature detection. TESs operated as microcalorimeters are compelling detectors for this application. Unlike semiconductor detectors, TESs eliminate the need for dispersive optics and are truly single photon detectors -- fundamental TES noise yields uncertainty in the energies of detected photons, not in the number of detected photons. We introduce TESs designed for this application and discuss the path toward realizing a TES-based dispersionless spectrometer optimized for biosignature detection.

Instrumentation and Photography↗

Development of Transition Edge Sensor Detectors Optimized for Single-Photon Spectroscopy in the Optical and Near-Infrared

The search for biosignatures in the atmospheres of exoplanets will be a key focus of future space telescopes that operate in the ultraviolet, visible, and near-infrared bands. Detection of biosignatures requires an instrument with moderate spectral resolving power (R ~ 100) and a large bandwidth (~ 400 nm – ~ 1.8 µm). Additionally, biosignature detection is a photon-starved science; instruments designed for these measurements would ideally combine high optical efficiency with quantum-limited photon detectors (i.e., detectors that exhibit zero dark current). In this work, we report on our efforts to develop energy resolving transition edge sensor (TES)-based detectors designed for biosignature detection. TESs operated as microcalorimeters are compelling detectors for this application. Unlike semiconductor detectors, TESs eliminate the need for dispersive optics and are truly single photon detectors – fundamental TES noise yields uncertainty in the energies of detected photons, not in the number of detected photons. We introduce TESs designed for this application and discuss the path toward realizing a TES-based dispersionless spectrometer optimized for biosignature detection.

Instrumentation and Photography↗

Evaluation of a hydrogen chloride detector for environmental monitoring

The paper describes a hydrogen chloride detector designed to monitor concentrations of hydrogen chloride gas in the ambient environment. The detector was developed for NASA for use in launch vehicle effluent monitoring. The detector operates on chemiluminescence principles with a lower detection limit of less than 5 x 10 to the -3rd ppm (by volume). The hydrogen chloride in the air sample reacts with a bromide-bromate coating in the inlet tube of the instrument producing bromine. Bromine is then quantitated by chemiluminescent oxidation of luminol. The visible light generated in the chemiluminescent reaction is proportional to the hydrogen chloride concentration of the sampled airstream. The detector is most suited to laboratory or field studies where hydrogen chloride is the dominant pollutant, as compared to the interfering species. Interferences include strong acids, acid-forming gases, and halogen gases. Of the interferences investigated the most serious in these groups are hydrochloric and sulfuric acid, sulfur dioxide, and chlorine, respectively. The detector has been in use since 1974 and has been found to be highly portable, rugged, and stable under extreme environmental conditions.

Gregory, G. L.↗

Intensified-CCD focal plane detector for space applications A second generation

An intensified-CCD detector system developed for space applications from commercially available components is described. This detector uses components which are readily available and are mechanically, thermally, and optically coupled to produce the final compact system. The CCD is cooled using a Peltier-effect thermoelectric cooler to reduce thermal noise. The image is formed on the photocathode of a proximity-focused image intensifier and is transferred fiber-optically from the intensifier to the CDD. Various photocathode and window materials are used to optimize the system for use within the wavelength range extending from the far UV to the near IR. The basic design, including the image intensifier, intensifier-CCD interface, CCD array, cooling, electronics, and mounting, and the detector performance are described in detail.

Torr, M. R.↗

Recent Developments in Transition-Edge Strip Detectors for Solar X-Rays

LMSAL and NIST are developing position-sensitive x-ray strip detectors based on Transition Edge Sensor (TES) microcalorimeters optimized for solar physics. By combining high spectral (E/ delta E approximately equals 1600) and temporal (single photon delta t approximately equals 10 micro s) resolutions with imaging capabilities, these devices will be able to study high-temperature (>l0 MK) x-ray lines as never before. Diagnostics from these lines should provide significant new insight into the physics of both microflares and the early stages of flares. Previously, the large size of traditional TESs, along with the heat loads associated with wiring large arrays, presented obstacles to using these cryogenic detectors for solar missions. Implementing strip detector technology at small scales, however, addresses both issues: here, a line of substantially smaller effective pixels requires only two TESs, decreasing both the total array size and the wiring requirements for the same spatial resolution. Early results show energy resolutions of delta E(sub fwhm) approximately equals 30 eV and spatial resolutions of approximately 10-15 micron, suggesting the strip-detector concept is viable.

Rausch, Adam J.↗

Development of Tiled Imaging CZT Detectors for Sensitive Wide-Field Hard X-Ray Surveys to EXIST

Motivated by the proposed EXIST mission, a "medium-class" space observatory to survey black holes and the Early Universe proposed to the 2010 NAS/NRC Astronomy and Astrophysics Decadal Survey, we have developed the first "large" area 256 sq cm close-tiled (0.6 mm gaps) hard X-ray (20-600 keV) imaging detector employing pixelated (2.5 mm) CdZnTe (CZT) detectors, each 2 x 2 x 0.5 cubic cm. We summarize the design, development and operation of this detector array (8 x 8 CZTs) and its performance as the imager for a coded aperture telescope on a high altitude (40 km) balloon flight in October. 2009, as the ProtoEX1STl payload. We then outline our current development of a second-generation imager, ProtcEXIST2. with 0.6 mm pixels on a 32 x 32 array on each CZT, and how it will lead to the ultimate imaging system needed for EXIST. Other applications of this technology will also be mentioned.

Grindlay, J.↗

Continuous Magnetic Refrigerators for Cooling in the 0.05 to 10 K Range: Progress and Future Development

Low temperature refrigeration is an increasingly vital technology for NASA s Space Science program since most detectors being developed for x-ray, IR and sub-millimeter missions must be cooled to below 100 mK in order to meet the requirements for energy and spatial resolution. For space applications, magnetic refrigeration has an inherent advantage over alternative techniques because it does not depend on gravity. Adiabatic demagnetization refrigerators, or ADRs, are relatively simple, solid state devices. The basic elements are a magnetocaloric refrigerant (usually an encapsulated paramagnetic salt) located in the bore of a superconducting magne$, and a heat switch linking the salt to a heat sink. The alignment of magnetic spins with the magnetic field causes the refrigerant to warm as the magnetic field increases and cool as the field decreases. Thus the simple process of magnetizing the refrigerant to high field with the heat switch closed, then demagnetizing it with the heat switch open allows one to obtain temperatures well below 100 mK using a heat sink as warm as 4.2 K. The refrigerant can maintain a low temperature for a length of time depending on the applied and parasitic heat loads, its mass, and the initial magnetic field strength. Typically ADRs are designed for 12-24 hours of hold time, after which they must be warmed up and recycled. The drawback to single-shot ADRs is that the cooling power per unit mass is relatively low. Refrigerants that are suitable for low temperature operation necessarily have low magnetic ion density, and therefore low entropy density. Since ADRs store entropy, systems with even modest cooling powers (a few microwatts) at temperatures below 100 mK tend to be massive, averaging 10-15 kg.

Shirron, Peter↗

First Results on the Search for Lepton Number Violating Neutrinoless Double-𝛽 Decay with the LEGEND-200 Experiment

The LEGEND Collaboration is searching for neutrinoless double-beta (0⁢𝜈⁢𝛽⁢𝛽) decay by operating high-purity germanium detectors enriched in 76 Ge in a low-background liquid argon environment. Building on key technological innovations from the GERmanium Detector Array (GERDA) experiment and the MAJORANA DEMONSTRATOR experiment, LEGEND-200 has performed a first 0⁢𝜈⁢𝛽⁢𝛽 decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of 0.5$^{+0.3}_{−0.2}$ ⁢cts/(keV ton yr) in the 0⁢𝜈⁢𝛽⁢𝛽 decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of 2.8 ×10 26 yr on the half-life of 0⁢𝜈⁢𝛽⁢𝛽 decay, reveals no evidence for a signal and sets a new observed lower limit at 𝑇$^{⁢0𝜈}_{1/2}$ > 1.9 × 10 26 yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range 𝑚 𝛽⁢𝛽 < 75–200 meV, depending on the adopted nuclear matrix element.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterizing Shielded Special Nuclear Material by Neutron Capture Gamma-Ray Multiplicity Counting

We present a new neutron multiplicity counting analysis and measurement method for neutron-shielded fissile material using neutron-capture gamma rays. Neutrons absorbed in shielding produce characteristic gamma rays that preserve the otherwise lost neutron multiplicity signature. Neutron multiplicity counting provides estimates of fission parameters, such as neutron leakage multiplication, spontaneous fissioner (e.g. Pu-240) mass, and (α,n) ratio. Standard neutron multiplicity counting can incorporate the new neutron-capture gamma-ray multiplicity counting technique to characterize previously degenerate or intractable source configurations by maximizing the multiplicity signature. The new method decouples neutron source-detector interferences, such as reflection and thermalization time in the detector, that could improve measurements of the mean neutron lifetime. We also develop a detector prototype for the multiplicity counting of neutron-capture gamma rays and present detector design considerations, such as detection material and shielding, to optimize the detection of the 2.2 MeV hydrogen capture gamma ray. We simulate the prototype neutron- capture gamma-ray multiplicity counter against the BeRP ball in polyethylene shells to inform future measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Complementary Barrier Infrared Detector (CBIRD) Contact Methods

The performance of the CBIRD detector is enhanced by using new device contacting methods that have been developed. The detector structure features a narrow gap adsorber sandwiched between a pair of complementary, unipolar barriers that are, in turn, surrounded by contact layers. In this innovation, the contact adjacent to the hole barrier is doped n-type, while the contact adjacent to the electron barrier is doped p-type. The contact layers can have wider bandgaps than the adsorber layer, so long as good electrical contacts are made to them. If good electrical contacts are made to either (or both) of the barriers, then one could contact the barrier(s) directly, obviating the need for additional contact layers. Both the left and right contacts can be doped either n-type or ptype. Having an n-type contact layer next to the electron barrier creates a second p-n junction (the first being the one between the hole barrier and the adsorber) over which applied bias could drop. This reduces the voltage drop over the adsorber, thereby reducing dark current generation in the adsorber region.

Ting, David Z.↗

Simulations of Silicon Radiation Detectors for High Energy Physics Experiments

Silicon radiation detectors are an integral component of current and planned collider experiments in high energy physics. Simulations of these detectors are essential for deciding operational configurations, for performing precise data analysis, and for developing future detectors. In this white paper, we briefly review the existing tools and discuss challenges for the future that will require research and development to be able to cope with the foreseen extreme radiation environments of the High Luminosity runs of the Large Hadron Collider and future hadron colliders like FCC-hh and SPPC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of mercuric iodide uncooled x ray detectors and spectrometers

The results obtained in the development of miniature, lowpower, light weight mercuric iodide, HgI2, x ray spectrometers for future space missions are summarized. It was demonstrated that HgI2 detectors can be employed in a high resolution x ray spectrometer, operating in a scanning electron microscope. Also, the development of HgI2 x ray detectors to augment alpha backscattering spectrometers is discussed. These combination instruments allow for the identification of all chemical elements, with the possible exception of hydrogen, and their respective concentrations. Additionally, further investigations of questions regarding radiation damage effects in the HgI2 x ray detectors are reported.

Iwanczyk, Jan S.↗

Enhancing ICARUS and REDTOP Software and Hardware: Event Generator Interface Development and Calorimeter Tile Prototype

ICARUS (Imaging Cosmic And Rare Underground Signals) is a liquid argon time projection chamber (LArTPC) detector that pursues the sterile neutrino, which relies on accurate simulations of neutrino-argon interactions. REDTOP (Rare Eta Decays To Observe new Physics) is a proposed low-energy, high-intensity meson factory designed to explore rare $\eta$/$\eta'$ meson decays and probe physics beyond the Standard Model. As a next-generation experiment, this requires both accurate simulations and innovative detector technologies. This project contributes to both ICARUS, from a simulation perspective, and REDTOP, from both a simulation and detection perspective, through the event generation of lepton-nucleon interactions and the physical enhancement of the calorimeter technology within the REDTOP detector. We developed an interface between ACHILLES (A CHIcago Land Lepton Event Simulator), a theory-driven lepton-level event generator, and GENIE, a robust event generator framework used for neutrino physics. By incorporating the precise theoretical cross-section calculations of ACHILLES into the experimental realism of GENIE, the interface allows for improved accuracy of neutrino-nucleon simulations, which can be adapted for the proton beam specifications of the REDTOP meson factory as well as for the ICARUS experiment. In parallel, we developed an improved prototype for the ADRIANO2 (A Dual Readout Integrally Active Non-segmented Option) dual-readout calorimeter tiles for the REDTOP detector. To improve the efficiency of the lead-glass tiles trapping Cherenkov light for energy reconstruction and particle identification, we optimized the application of a highly reflective coating. Through viscosity and thickness control, masking, and a custom spray technique, we refined the coating process to reduce surface defects and improve light yield. Together, these efforts strengthen the ICARUS neutrino program and REDTOP's capability of detecting rare decay events.

Visser, Erin [Michigan State U.] (ORCID:0009000184↗

Radiation hardness of the low gain avalanche diodes developed by NDL and IHEP in China

This paper presents a study on the radiation hardness of low gain avalanche detector (LGAD) developed by the Novel Device Laboratory (NDL) in Beijing and the Institute of High Energy Physics (IHEP) of Chinese Academy of Sciences, in the context of an upgrade project of the ATLAS detector for the high luminosity phase of LHC. NDL LGAD sensors with different layouts, epitaxial resistivity and doping profile were irradiated up to 1.02 × 10 15 n eq /cm 2 by 70 MeV protons at Cyclotron and Radioisotope Center (CYRIC). The timing resolution of NDL LGAD sensors reached 50 ps and the collected charge reached 3 - 4 fC after irradiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Short-Baseline Near Detector at Fermilab: Input to the European Strategy for Particle Physics 2026 Update

SBND is a 112 ton liquid argon time projection chamber (LArTPC) neutrino detector located 110 meters from the Booster Neutrino Beam (BNB) target at Fermilab. Its main goals include searches for eV-scale sterile neutrinos as part of the Short-Baseline Neutrino (SBN) program, other searches for physics beyond the Standard Model, and precision studies of neutrino-argon interactions. In addition, SBND is providing a platform for LArTPC neutrino detector technology development and is an excellent training ground for the international group of scientists and engineers working towards the upcoming flagship Deep Underground Neutrino Experiment (DUNE). SBND began operation in July 2024, and started collecting stable neutrino beam data in December 2024 with an unprecedented rate of ~7,000 neutrino events per day. During its currently approved operation plans (2024-2027), SBND is expected to accumulate nearly 10 million neutrino interactions. The near detector dataset will be instrumental in testing the sterile neutrino hypothesis with unprecedented sensitivity in SBN and in probing signals of beyond the Standard Model physics. It will also be used to significantly advance our understanding of the physics of neutrino-argon interactions ahead of DUNE. After the planned accelerator restart at Fermilab (2029+), opportunities are being explored to operate SBND in antineutrino mode in order to address the scarcity of antineutrino-argon scattering data, or in a dedicated beam-dump mode to significantly enhance sensitivity to searches for new physics. SBND is an international effort, with approximately 40% of institutions from Europe, contributing to detector construction, commissioning, software development, and data analysis. Continued European involvement and leadership are essential during SBND's operations and analysis phase for both the success of SBND, SBN and its role leading up to DUNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

YSO implantation detector for beta-delayed neutron spectroscopy

A segmented-scintillator-based implantation detector was developed to study the energy distribution of β-delayed neutrons emitted from exotic isotopes. The detector comprises a 34 × 34 YSO scintillator coupled to an 8 × 8 anode Position-Sensitive Photo-Multiplier Tube (PSPMT) via a tapered light guide. The detector was used at RIBF, RIKEN for time-of-flight-based neutron spectroscopy measurement in the 78Ni region. The detector provides the position and timing resolution necessary for ion-beta correlations and time of flight measurements. The detector provides a high ~80% beta-detection efficiency and a sub-nanosecond timing resolution. This contribution discusses the details of the design, operation, implementation, and analysis developed to obtain neutron time-of-flight spectrum and the analysis methods in the context of neutron-rich nuclei in the 78Ni region.

Implantation detector↗

Development of High-Performance Detector Technology for UV and IR Applications

Sensing and imaging for ultraviolet (UV) and infrared (IR) bands has many applications for NASA, defense, and commercial systems. Recent work has involved developing UV avalanche photodiode (UVAPD) arrays with high gain for high resolution imaging. Various GaN/AlGaN p-i-n UV-APDs have been fabricated from epitaxial structures grown by metalorganic chemical vapor deposition (MOCVD) on GaN substrates with avalanche gains greater than 5×105, and high responsivities. Similarly, the IR spectral band is useful for measuring ocean temperatures, atmospheric aerosols, forest fires, etc. We are also developing room temperature operating graphene-enhanced PbSe midwave infrared (MWIR) detectors and focal plane arrays (FPAs). These compact and low-cost MWIR sensors can benefit various NASA remote sensing applications. Here we present recent results from these high performance UV- and IR-band detector and FPA technologies.

Sood, Ashok K.↗