Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital Devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

SSRL Emergency Response Shore Tool

The SSRL Emergency Response Shore Tool (wherein SSRL signifies Smart Systems Research Laboratory ) is a computer program within a system of communication and mobile-computing software and hardware being developed to increase the situational awareness of first responders at building collapses. This program is intended for use mainly in planning and constructing shores to stabilize partially collapsed structures. The program consists of client and server components, runs in the Windows operating system on commercial off-the-shelf portable computers, and can utilize such additional hardware as digital cameras and Global Positioning System devices. A first responder can enter directly, into a portable computer running this program, the dimensions of a required shore. The shore dimensions, plus an optional digital photograph of the shore site, can then be uploaded via a wireless network to a server. Once on the server, the shore report is time-stamped and made available on similarly equipped portable computers carried by other first responders, including shore wood cutters and an incident commander. The staff in a command center can use the shore reports and photographs to monitor progress and to consult with structural engineers to assess whether a building is in imminent danger of further collapse.

Mah, Robert W.↗

A systolic architecture for the correlation and accumulation of digital sequences

A fully systolic architecture for the implementation of digital sequence correlator/accumulators is described. These devices consist of a two-dimensional array of processing elements that are conceived for efficient fabrication in Very Large Scale Integrated (VLSI) circuits. A custom VLSI chip that was implemented using these concepts is described. The chip, which contains a four-lag three-level sequence correlator and four bits of accumulation with overflow detection, was designed using the Integrated UNIX-Based Computer Aided Design (CAD) System. Applications of such devices include the synchronization of coded telemetry data, alignment of both real time and non-real time Very Large Baseline Interferometry (VLBI) signals, and the implementation of digital filters and processes of many types.

Deutsch, L. J.↗

A hybrid general-purpose bit synchronizer

Synchronizer is not affected by severe noise environments. Device uses both analog and digital techniques in its tracking loop. It accommodates any one of three signal formats. Rapid acquisition sequences are used to minimize acquisition time.

Stiffler, J. J.↗

Computerized thermal transient test console

A system for nondestructively testing electroexplosive devices by the thermal transient test technique is described. The signal, which is generated by pulsing the electroexplosive device bridgewire is reduced to digital form. The data is then interpreted by an appropriate program and the essential electrothermal parameters are resolved. The system is fast, eliminates arbitrary interpretation of the analog, and lends itself to production testing.

Menichelli, V. J.↗

Geodetic Accuracy of LANDSAT-4 Multispectral Scanner and Thematic Mapper Data

The geodetic accuracy of an MSS or TM scene is assessed using a minicomputer and appropriate software, a digitizer, and an image display device. The calculated image location of a selected feature is compared with the actual image location obtained though visual inspection of the image on the display. Measurements of 15 to 20 features evenly distributed throughout the image provide an estimate of the geodetic accuracy of the scene. Tests of two system-corrected MSS scenes measured geodetic registration root-mean-square (RMS) errors of approximately 3,200 m or 57 pixels. Tests of two TM system-corrected scenes measured RMS errors of approximately 1,250 and 1,000 m, or 44 and 35 pixels, respectively. All errors were primarily translational, implying good internal scene registration of both MSS and TM data. The one MSS GCP-corrected scene which was evaluated had an RMS error of approximately 325 m or 6 pixels.

Thormodsgard, J. M.↗

Processing Laser-Velocimetric Data By Vector Scanning

Velocity plots obtained in minutes instead of hours. Velocity scanning technique for processing flow-field data from pulsed-laser-velocimetry images into two-dimensional velocity-vector maps. Requires no special equipment other than charge-coupled-device (CCD) camera, circuitry to digitize output of camera, and computer. Once image data digitized, all processing done in computer.

Wernet, Mark P.↗

System for memorizing maximum values

The invention discloses a system capable of memorizing maximum sensed values. The system includes conditioning circuitry which receives the analog output signal from a sensor transducer. The conditioning circuitry rectifies and filters the analog signal and provides an input signal to a digital driver, which may be either linear or logarithmic. The driver converts the analog signal to discrete digital values, which in turn triggers an output signal on one of a plurality of driver output lines n. The particular output lines selected is dependent on the converted digital value. A microfuse memory device connects across the driver output lines, with n segments. Each segment is associated with one driver output line, and includes a microfuse that is blown when a signal appears on the associated driver output line.

Bozeman, Richard J., Jr.↗

A fuzzy control design case: The fuzzy PLL

The aim of this paper is to present a typical fuzzy control design case. The analyzed controlled systems are the phase-locked loops (PLL's)--classic systems realized in both analogic and digital technology. The crisp PLL devices are well known.

Teodorescu, H. N.↗

Acoustic charge transport technology investigation for advanced development transponder

Acoustic charge transport (ACT) technology has provided a basis for a new family of analog signal processors, including a programmable transversal filter (PTF). Through monolithic integration of ACT delay lines with GaAs metal semiconductor field effect transistor (MESFET) digital memory and controllers, these devices significantly extend the performance of PTF's. This article introduces the basic operation of these devices and summarizes their present and future specifications. The production and testing of these devices indicate that this new technology is a promising one for future space applications.

Kayalar, S.↗

Simulation of arthroscopic surgery using MRI data

With the availability of Magnetic Resonance Imaging (MRI) technology in the medical field and the development of powerful graphics engines in the computer world the possibility now exists for the simulation of surgery using data obtained from an actual patient. This paper describes a surgical simulation system which will allow a physician or a medical student to practice surgery on a patient without ever entering an operating room. This could substantially lower the cost of medial training by providing an alternative to the use of cadavers. This project involves the use of volume data acquired by MRI which are converted to polygonal form using a corrected marching cubes algorithm. The data are then colored and a simulation of surface response based on springy structures is performed in real time. Control for the system is obtained through the use of an attached analog-to-digital unit. A remote electronic device is described which simulates an imaginary tool having features in common with both arthroscope and laparoscope.

Heller, Geoffrey↗

System for Memorizing Maximum Values

The invention discloses a system capable of memorizing maximum sensed values. The system includes conditioning circuitry which receives the analog output signal from a sensor transducer. The conditioning circuitry rectifies and filters the analog signal and provides an input signal to a digital driver, which may be either liner or logarithmic. The driver converts the analog signal to discrete digital values, which in turn triggers an output signal on one of a plurality of driver output lines n. The particular output lines selected is dependent on the converted digital value. A microfuse memory device connects across the driver output lines, with n segments. Each segment is associated with one driver output line, and includes a microfuse that is blown when a signal appears on the associated driver output line.

Bozeman, Richard J., Jr.↗

Hardware platforms for MEMS gyroscope tuning based on evolutionary computation using open-loop and closed -loop frequency response

We propose a tuning method for MEMS gyroscopes based on evolutionary computation to efficiently increase the sensitivity of MEMS gyroscopes through tuning. The tuning method was tested for the second generation JPL/Boeing Post-resonator MEMS gyroscope using the measurement of the frequency response of the MEMS device in open-loop operation. We also report on the development of a hardware platform for integrated tuning and closed loop operation of MEMS gyroscopes. The control of this device is implemented through a digital design on a Field Programmable Gate Array (FPGA). The hardware platform easily transitions to an embedded solution that allows for the miniaturization of the system to a single chip.

evolvable hardware↗

A Hardware Platform for Tuning of MEMS Devices Using Closed-Loop Frequency Response

We report on the development of a hardware platform for integrated tuning and closed-loop operation of MEMS gyroscopes. The platform was developed and tested for the second generation JPL/Boeing Post-Resonator MEMS gyroscope. The control of this device is implemented through a digital design on a Field Programmable Gate Array (FPGA). A software interface allows the user to configure, calibrate, and tune the bias voltages on the micro-gyro. The interface easily transitions to an embedded solution that allows for the miniaturization of the system to a single chip.

gyroscope controls↗

Medical Signal-Conditioning and Data-Interface System

A general-purpose portable, wearable electronic signal-conditioning and data-interface system is being developed for medical applications. The system can acquire multiple physiological signals (e.g., electrocardiographic, electroencephalographic, and electromyographic signals) from sensors on the wearer s body, digitize those signals that are received in analog form, preprocess the resulting data, and transmit the data to one or more remote location(s) via a radiocommunication link and/or the Internet. The system includes a computer running data-object-oriented software that can be programmed to configure the system to accept almost any analog or digital input signals from medical devices. The computing hardware and software implement a general-purpose data-routing-and-encapsulation architecture that supports tagging of input data and routing the data in a standardized way through the Internet and other modern packet-switching networks to one or more computer(s) for review by physicians. The architecture supports multiple-site buffering of data for redundancy and reliability, and supports both real-time and slower-than-real-time collection, routing, and viewing of signal data. Routing and viewing stations support insertion of automated analysis routines to aid in encoding, analysis, viewing, and diagnosis.

Braun, Jeffrey↗

Alkaline Capacitors Based on Nitride Nanoparticles

High-energy-density alkaline electrochemical capacitors based on electrodes made of transition-metal nitride nanoparticles are undergoing development. Transition- metal nitrides (in particular, Fe3N and TiN) offer a desirable combination of high electrical conductivity and electrochemical stability in aqueous alkaline electrolytes like KOH. The high energy densities of these capacitors are attributable mainly to their high capacitance densities, which, in turn, are attributable mainly to the large specific surface areas of the electrode nanoparticles. Capacitors of this type could be useful as energy-storage components in such diverse equipment as digital communication systems, implanted medical devices, computers, portable consumer electronic devices, and electric vehicles.

Aldissi, Matt↗

Characterization of the Vectron PX-570 Crystal Oscillator for Use in Harsh Environments

Computing hardware, data-acquisition systems, communications systems, and many electronic control systems require well-controlled timing signals for proper and accurate operation. These signals are, in most cases, provided by circuits that employ crystal oscillators due to availability, cost, ease of operation, and accuracy. In some cases, the electronic systems are expected to survive and operate under harsh conditions that include exposure to extreme temperatures. These applications exist in terrestrial systems as well as in aerospace products. Well-logging, geothermal systems, and industrial process control are examples of ground-based applications, while distributed jet engine control in aircraft, space-based observatories (such as the James Webb Space Telescope), satellites, and lunar and planetary landers are typical environments where electronics are exposed to harsh operating conditions. To ensure these devices produce reliable results, the digital heartbeat from the oscillator must deliver a stable signal that is not affected by external temperature or other conditions. One such solution is a recently introduced commercial-off-the-shelf (COTS) oscillator, the PX-570 series from Vectron International. The oscillator was designed for high-temperature applications and as proof, the crystal oscillator was subjected to a wide suite of tests to determine its ruggedness for operation in harsh environments. The tests performed by Vectron included electrical characterization under wide range of temperature, accelerated life test/aging, shock and vibration, internal moisture analysis, ESD threshold, and latch-up testing. The parametric evaluation was performed on the oscillator's frequency, output signal rise and fall times, duty cycle, and supply current over the temperature range of -125 C to +230 C. The evaluations also determined the effects of thermal cycling and the oscillator's re-start capability at extreme hot and cold temperatures. These thermal cycling and restart tests were performed at the NASA Glenn Research Center. Overall, the crystal oscillator performed well and demonstrated very good frequency stability. This paper will discuss the test procedures and present details of the performance results.

Li, Jacob↗