Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

AVIRIS and TIMS data processing and distribution at the land processes distributed active archive center

The U.S. Government has initiated the Global Change Research program, a systematic study of the Earth as a complete system. NASA's contribution of the Global Change Research Program is the Earth Observing System (EOS), a series of orbital sensor platforms and an associated data processing and distribution system. The EOS Data and Information System (EOSDIS) is the archiving, production, and distribution system for data collected by the EOS space segment and uses a multilayer architecture for processing, archiving, and distributing EOS data. The first layer consists of the spacecraft ground stations and processing facilities that receive the raw data from the orbiting platforms and then separate the data by individual sensors. The second layer consists of Distributed Active Archive Centers (DAAC) that process, distribute, and archive the sensor data. The third layer consists of a user science processing network. The EOSDIS is being developed in a phased implementation. The initial phase, Version 0, is a prototype of the operational system. Version 0 activities are based upon existing systems and are designed to provide an EOSDIS-like capability for information management and distribution. An important science support task is the creation of simulated data sets for EOS instruments from precursor aircraft or satellite data. The Land Processes DAAC, at the EROS Data Center (EDC), is responsible for archiving and processing EOS precursor data from airborne instruments such as the Thermal Infrared Multispectral Scanner (TIMS), the Thematic Mapper Simulator (TMS), and Airborne Visible and Infrared Imaging Spectrometer (AVIRIS). AVIRIS, TIMS, and TMS are flown by the NASA-Ames Research Center ARC) on an ER-2. The ER-2 flies at 65000 feet and can carry up to three sensors simultaneously. Most jointly collected data sets are somewhat boresighted and roughly registered. The instrument data are being used to construct data sets that simulate the spectral and spatial characteristics of the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) instrument scheduled to be flown on the first EOS-AM spacecraft. The ASTER is designed to acquire 14 channels of land science data in the visible and near-IR (VNIR), shortwave-IR (SWIR), and thermal-IR (TIR) regions from 0.52 micron to 11.65 micron at high spatial resolutions of 15 m to 90 m. Stereo data will also be acquired in the VNIR region in a single band. The AVIRIS and TMS cover the ASTER VNIR and SWIR bands, and the TIMS covers the TIR bands. Simulated ASTER data sets have been generated over Death Valley, California, Cuprite, Nevada, and the Drum Mountains, Utah using a combination of AVIRIS, TIMS, amd TMS data, and existing digital elevation models (DEM) for the topographic information.

Mah, G. R.↗

Measurement of the Vertical Distribution of Aerosol by Globally Distributed MP Lidar Network Sites

The global distribution of aerosol has an important influence on climate through the scattering and absorption of shortwave radiation and through modification of cloud optical properties. Current satellite and other data already provide a great amount of information on aerosol distribution. However there are critical parameters that can only be obtained by active optical profiling. For aerosol, no passive technique can adequately resolve the height profile of aerosol. The aerosol height distribution is required for any model for aerosol transport and the height resolved radiative heating/cooling effect of aerosol. The Geoscience Laser Altimeter System (GLAS) is an orbital lidar to be launched by 2002. GLAS will provide global measurements of the height distribution of aerosol. The sampling will be limited by nadir only coverage. There is a need for local sites to address sampling, and accuracy factors. Full time measurements of the vertical distribution of aerosol are now being acquired at a number of globally distributed MP (micro pulse) lidar sites. The MP lidar systems provide profiling of all significant cloud and aerosol to the limit of signal attenuation from compact, eye safe instruments. There are currently six sites in operation and over a dozen planned. At all sites there are a complement of passive aerosol and radiation measurements supporting the lidar data. Four of the installations are at Atmospheric Radiation Measurement program sites. The aerosol measurements, retrievals and data products from the network sites will be discussed. The current and planned application of data to supplement satellite aerosol measurements is covered.

Spinhirne, James↗

Product Distributions for Distributed Optimization

With connections to bounded rational game theory, information theory and statistical mechanics, Product Distribution (PD) theory provides a new framework for performing distributed optimization. Furthermore, PD theory extends and formalizes Collective Intelligence, thus connecting distributed optimization to distributed Reinforcement Learning (FU). This paper provides an overview of PD theory and details an algorithm for performing optimization derived from it. The approach is demonstrated on two unconstrained optimization problems, one with discrete variables and one with continuous variables. To highlight the connections between PD theory and distributed FU, the results are compared with those obtained using distributed reinforcement learning inspired optimization approaches. The inter-relationship of the techniques is discussed.

Bieniawski, Stefan R.↗

Comparison of Measured Dark Current Distributions with Calculated Damage Energy Distributions in HgCdTe

This paper presents a combined Monte Carlo and analytic approach to the calculation of the pixel-to-pixel distribution of proton-induced damage in a HgCdTe sensor array and compares the results to measured dark current distributions after damage by 63 MeV protons. The moments of the Coulombic, nuclear elastic and nuclear inelastic damage distributions were extracted from Monte Carlo simulations and combined to form a damage distribution using the analytic techniques first described in [1]. The calculations show that the high energy recoils from the nuclear inelastic reactions (calculated using the Monte Carlo code MCNPX [2]) produce a pronounced skewing of the damage energy distribution. While the nuclear elastic component (also calculated using the MCNPX) contributes only a small fraction of the total nonionizing damage energy, its inclusion in the shape of the damage across the array is significant. The Coulombic contribution was calculated using MRED [3-5], a Geant4 [4,6] application. The comparison with the dark current distribution strongly suggests that mechanisms which are not linearly correlated with nonionizing damage produced according to collision kinematics are responsible for the observed dark current increases. This has important implications for the process of predicting the on-orbit dark current response of the HgCdTe sensor array.

Marshall, C. J.↗

Hierarchal framework for integrating distributed energy resources into distribution systems

Methods and apparatus are disclosed for providing a hierarchical framework for integrating distributed energy resources into power distribution systems. In one example of the disclosed technology, a method implemented with an aggregation server includes receiving a respective utility function associated with each of at least two of a plurality of distributed energy resources representing an amount of energy produced or consumed by the respective associated distributed energy resource as a function of energy price, producing an aggregated utility function associated with the plurality of distributed energy resources based on the received utility functions, transmitting the produced aggregated utility function to a coordinator, receiving a clearing value from the coordinator, and transmitting the received clearing value to each of the plurality of distributed energy resources.

Lian, Jianming↗

Device and methods for determination of molecular weight distributions of polymers and distributions of other polymer properties without physical separation

Devices and methods for determining the cumulative distribution of a polymer property in a reactor without physical separation of reaction subcomponents. The device includes a means of measuring an instantaneous property of the polymers being produced in a reaction vessel a plurality of times during a polymerization reaction as well as a means of determining the corresponding change in polymer concentration in the reaction vessel between measurements of the instantaneous polymer property The device also includes a means of computing a statistical distribution appropriate to the polymer characteristic and applying the statistical distribution to a recently measured instantaneous value of the polymer property so as to have an instantaneous distribution of the polymer property and a means of adding together the instantaneous distributions of the polymer property in order to obtain the cumulative distribution of the polymer property in the reactor.

Reed, Wayne Frederick↗

Device and methods for determination of molecular weight distributions of polymers and distributions of other polymer properties without physical separation

Devices and methods for determining the cumulative distribution of a polymer property in a reactor without physical separation of reaction subcomponents. The device includes a means of measuring an instantaneous property of the polymers being produced in a reaction vessel a plurality of times during a polymerization reaction as well as a means of determining the corresponding change in polymer concentration in the reaction vessel between measurements of the instantaneous polymer property. The device also includes a means of computing a statistical distribution appropriate to the polymer characteristic and applying the statistical distribution to a recently measured instantaneous value of the polymer property so as to have an instantaneous distribution of the polymer property and a means of adding together the instantaneous distributions of the polymer property in order to obtain the cumulative distribution of the polymer property in the reactor.

Reed, Wayne Frederick↗

Coordinated Optimization of Distributed Energy Resources and Smart Loads in Distribution Systems

Distributed energy resources (DERs) and smart loads have the potential to provide flexibility to the distribution system operation. A coordinated optimization approach is proposed in this paper to actively manage DERs and smart loads in distribution systems to achieve the optimal operation status. A three-phase unbalanced Optimal Power Flow (OPF) problem is developed to determine the output from DERs and smart loads with respect to the system operator's control objective. This paper focuses on coordinating PV systems and smart loads to improve the overall voltage profile in distribution systems. Simulations have been carried out in a 12-bus distribution feeder and results illustrate the superior control performance of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimating Spatial Distribution Impacts of Rooftops Solar PV on Dynamic Hosting Capacity Evaluation for a Real Distribution Feeder

This paper models the sensitivity of dynamic hosting capacity analysis to the spatial distribution of distributed PV scenarios, random, close and far from substation deployments, at various penetration levels on a real distribution feeder, in a quasi-static time series (QSTS) power flow simulation using high resolution time-aware metrics. These spatial distribution scenarios were chosen to capture a wide range of potential operation impacts of these deployments using a set of thermaland voltage-based metrics such as instantaneous violations and moving averages for both thermal and voltage constraints. This study uses actual load and PV data up-scaled from 1-hour time step to 1-minute resolution to fully characterize the interaction between the daily changes in load and PV output, and their impacts on distribution system operations.

distribution system↗

A Data-Driven Voltage Control Strategy for Distribution Grids With Distributed Energy Resources

Traditionally, distribution system control approaches have been model-based. The deployment of advanced metering infrastructure has provided electric utilities with the capability of data-driven control with real-time measurements. The shift from model-based to data-driven control represents a significant advancement in the management of distribution systems, offering a more adaptive approach to system control because of the ability to dynamically adapt to changing conditions without the need for system modeling. Here, in this paper, a behavioral data-driven control method is developed to provide voltage regulation to an actual distribution system by controlling the legacy devices and distributed energy resource (DER) assets. The studied distribution system has a load tap changer and three capacitor banks as the legacy devices and photovoltaic systems as the DERs. The performance of the proposed control algorithm is validated using a laboratory test bed setup considering multiple scenarios. The results show that the proposed control achieved 99% voltage regulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributionally Robust Bilevel Optimization Model for Distribution Network With Demand Response Under Uncertain Renewables Using Wasserstein Metrics

Here, we consider a distribution network integrating demand response (DR) participants in the presence of uncertain renewable suppliers and outdoor temperatures. A bilevel optimization model is proposed to capture the intricate dynamics between price-incentivized DR participants and distribution system operations, including energy procurement and active/reactive power flows. The model is formulated as a distributional robust bilevel optimization using Wasserstein metrics. We show favorable data-driven properties including out-of-sample guarantee and asymptotic consistency. Furthermore, we present a tractable mixed-integer linear programming reformulation and characterize the worst-case distribution. Computational experiments are conducted on a modified 33-bus system. Our findings underscore the efficacy of the pricing strategies derived from the proposed bilevel optimization model. These strategies not only effectively manage DR participants' behavior but also bring equity considerations among households with various characteristics to light. The results contribute to a deeper understanding of the interplay between distribution system operators and DR participants.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordinated Optimization of Distributed Energy Resources and Smart Loads in Distribution Systems: Preprint

Distributed energy resources (DERs) and smart loads have the potential to provide flexibility to the distribution system operation. A coordinated optimization approach is proposed in this paper to actively manage DERs and smart loads in distribution systems to achieve the optimal operation status. A three-phase unbalanced Optimal Power Flow (OPF) problem is developed to determine the output from DERs and smart loads with respect to the system operator's control objective. This paper focuses on coordinating PV systems and smart loads to improve the overall voltage profile in distribution systems. Simulations have been carried out in a 12-bus distribution feeder and results illustrate the superior control performance of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources: Preprint

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS—based on real-time optimal power flow—controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

61 RADIATION PROTECTION AND DOSIMETRY↗

Automatic Regionalization Algorithm for Distributed State Estimation in Power Systems

The deregulation of the power system and the incorporation of generation from renewable energy sources recessitates faster state estimation in the smart grid. Distributed state estimation (DSE) has become a promising and scalable solution to this urgent demand. In this paper, we investigate the regionalization algorithms for the power system, a necessary step before distributed state estimation can be performed. To the best of the authors' knowledge, this is the first investigation on automatic regionalization (AR). We propose three spectral clustering based AR algorithms. Simulations show that our proposed algorithms outperform the two investigated manual regionalization cases. With the help of AR algorithms, we also show how the number of regions impacts the accuracy and convergence speed of the DSE and conclude that the number of regions needs to be chosen carefully to improve the convergence speed of DSEs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantifying Power Distribution System Resiliency Using Code-Based Metric

It is essential to improve the resiliency of power distribution systems (PDS) with the increase in extreme weather events, number of malicious threats and consumers’ need for higher reliability. Here, this paper provides a formal approach to evaluate the operational resiliency of PDS, and quantify the resiliency of a system using a code-based metric. A combination of steady state and dynamic simulation tools is used to determine the resiliency metric. Dynamic simulation tools help with analyzing impact of short-term events, which might affect operational resiliency in long term. A dynamic optimization algorithm for changing operating criteria to increase the sustainability of the most critical loads has been proposed. The proposed theoretical approach is validated using a simple power distribution system model and simulation results demonstrate the ability to quantify the resiliency using the proposed code-based metric. The time-dependent quantification of resiliency has been demonstrated on a test system of two connected CERTS microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Planning for a Distributed Disruption: Innovative Practices for Incorporating Distributed Solar into Utility Planning

The rapid growth of distributed solar photovoltaics (DPV) has critical implications for U.S. utility planning processes. This report informs utility planning through a comparative analysis of roughly 30 recent utility integrated resource plans or other generation planning studies, transmission planning studies, and distribution system plans. It reveals a spectrum of approaches to incorporating DPV across nine key planning areas, and it identifies areas where even the best current practices might be enhanced. (1) Forecasting DPV deployment: Because it explicitly captures several predictive factors, customer-adoption modeling is the most comprehensive forecasting approach. It could be combined with other forecasting methods to generate a range of potential futures. (2) Ensuring robustness of decisions to uncertain DPV quantities: using a capacity-expansion model to develop least-cost plans for various scenarios accounts for changes in net load and the generation portfolio; an innovative variation of this approach combines multiple per-scenario plans with trigger events, which indicate when conditions have changed sufficiently from the expected to trigger modifications in resource-acquisition strategy. (3) Characterizing DPV as a resource option: Today's most comprehensive plans account for all of DPV's monetary costs and benefits. An enhanced approach would address non-monetary and societal impacts as well. (4) Incorporating the non-dispatchability of DPV into planning: Rather than having a distinct innovative practice, innovation in this area is represented by evolving methods for capturing this important aspect of DPV. (5) Accounting for DPV's location-specific factors: The innovative propensity-to-adopt method employs several factors to predict future DPV locations. Another emerging utility innovation is locating DPV strategically to enhance its benefits. (6) Estimating DPV's impact on transmission and distribution investments: Innovative practices are being implemented to evaluate system needs, hosting capacities, and system investments needed to accommodate DPV deployment. (7) Estimating avoided losses associated with DPV: A time-differentiated marginal loss rate provides the most comprehensive estimate of avoided losses due to DPV, but no studies appear to use it. (8) Considering changes in DPV's value with higher solar penetration: Innovative methods for addressing the value changes at high solar penetrations are lacking among the studies we evaluate. (9) Integrating DPV in planning across generation, transmission, and distribution: A few states and regions have started to develop more comprehensive processes that link planning forums, but there are still many issues to address.

14 SOLAR ENERGY↗

An Analysis Framework for Distribution Network DER Integration Analysis in India: Distributed Solar in Tamil Nadu

This report is part of a two-part series that represents a year-long collaboration with the Tamil Nadu Generation and Distribution Corporation Limited (TANGEDCO) on power sector planning. The first report in this series, the Pathways for Tamil Nadu’s Electric Power Sector 2017-2030 report outlines NREL’s work with TANGEDCO's electricity sector planning department to develop a model of the State’s power system and evaluate multiple scenarios of system growth given resource constraints, costs of technologies, and power sector policies. This second report in this series focuses on the rapidly transforming distribution network in the State. The report outlines a framework developed by NREL with TANGEDCO's distribution utility to quickly and accurately analyze the impacts of integrating renewable energy, specifically rooftop solar PV onto Tamil Nadu's distribution system. Together these studies help to prepare Tamil Nadu for a rapidly transforming power system.

14 SOLAR ENERGY↗