Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A Monte Carlo calculation model of electronic portal imaging device for transit dosimetry through heterogeneous media

Purpose: To develop and evaluate a fast Monte Carlo (MC) dose calculation model of electronic portal imaging device (EPID) based on its effective atomic number modeling in the XVMC code. Methods: A previously developed EPID model, based on the XVMC code by density scaling of EPID structures, was modified by additionally considering effective atomic number (Z{sub eff}) of each structure and adopting a phase space file from the EGSnrc code. The model was tested under various homogeneous and heterogeneous phantoms and field sizes by comparing the calculations in the model with measurements in EPID. In order to better evaluate the model, the performance of the XVMC code was separately tested by comparing calculated dose to water with ion chamber (IC) array measurement in the plane of EPID. Results: In the EPID plane, calculated dose to water by the code showed agreement with IC measurements within 1.8%. The difference was averaged across the in-field regions of the acquired profiles for all field sizes and phantoms. The maximum point difference was 2.8%, affected by proximity of the maximum points to penumbra and MC noise. The EPID model showed agreement with measured EPID images within 1.3%. The maximum point difference was 1.9%. The difference dropped from the higher value of the code by employing the calibration that is dependent on field sizes and thicknesses for the conversion of calculated images to measured images. Thanks to the Z{sub eff} correction, the EPID model showed a linear trend of the calibration factors unlike those of the density-only-scaled model. The phase space file from the EGSnrc code sharpened penumbra profiles significantly, improving agreement of calculated profiles with measured profiles. Conclusions: Demonstrating high accuracy, the EPID model with the associated calibration system may be used for in vivo dosimetry of radiation therapy. Through this study, a MC model of EPID has been developed, and their performance has been rigorously investigated for transit dosimetry.

60 APPLIED LIFE SCIENCES↗

A comparison of depth dependence of dose and linear energy transfer spectra in aluminum and polyethylene

A set of four tissue-equivalent proportional counters (TEPCs), with their detector heads at the centers of 0 (bare), 3, 7 and 9-inch-diameter aluminum spheres, were flown on Shuttle flight STS-89. Five such detectors at the centers of polyethylene spheres were flown 1 year earlier on STS-81. The results of dose-depth dependence for the two materials convincingly show the merits of using material rich in hydrogen to decrease the radiation exposure to the crew. A comparison of the calculated galactic cosmic radiation (GCR) absorbed dose and dose-equivalent rates using the radiation transport code HZETRN with nuclear fragmentation model NUCFRG2 and the measured GCR absorbed dose rates and dose-equivalent rates shows that they agree within root mean square (rms) error of 12.5 and 8.2%, respectively. However, there are significant depth-dependent differences in the linear energy transfer (LET) spectra. A comparison for trapped protons using the proton transport code BRYNTRN and the AP-8 MIN trapped-proton model shows a systematic bias, with the model underpredicting dose and dose-equivalent rates. These results show the need for improvements in the radiation transport and/or fragmentation models.

manned↗

Magnetic Resonance Imaging-Based Radiation-Absorbed Dose Estimation of {sup 166}Ho Microspheres in Liver Radioembolization

Purpose: To investigate the potential of magnetic resonance imaging (MRI) for accurate assessment of the three-dimensional {sup 166}Ho activity distribution to estimate radiation-absorbed dose distributions in {sup 166}Ho-loaded poly (L-lactic acid) microsphere ({sup 166}Ho-PLLA-MS) liver radioembolization. Methods and Materials: MRI, computed tomography (CT), and single photon emission CT (SPECT) experiments were conducted on an anthropomorphic gel phantom with tumor-simulating gel samples and on an excised human tumor-bearing liver, both containing known amounts of {sup 166}Ho-PLLA-MS. Three-dimensional radiation-absorbed dose distributions were estimated at the voxel level by convolving the {sup 166}Ho activity distribution, derived from quantitative MRI data, with a {sup 166}Ho dose point-kernel generated by MCNP (Monte Carlo N-Particle transport code) and from Medical Internal Radiation Dose Pamphlet 17. MRI-based radiation-absorbed dose distributions were qualitatively compared with CT and autoradiography images and quantitatively compared with SPECT-based dose distributions. Both MRI- and SPECT-based activity estimations were validated against dose calibrator measurements. Results: Evaluation on an anthropomorphic phantom showed that MRI enables accurate assessment of local {sup 166}Ho-PLLA-MS mass and activity distributions, as supported by a regression coefficient of 1.05 and a correlation coefficient of 0.99, relating local MRI-based mass and activity calculations to reference values obtained with a dose calibrator. Estimated MRI-based radiation-absorbed dose distributions of {sup 166}Ho-PLLA-MS in an ex vivo human liver visually showed high correspondence to SPECT-based radiation-absorbed dose distributions. Quantitative analysis revealed that the differences in local and total amounts of {sup 166}Ho-PLLA-MS estimated by MRI, SPECT, and the dose calibrator were within 10%. Excellent agreement was observed between MRI- and SPECT-based dose-volume histograms. Conclusions: Quantitative MRI was demonstrated to provide accurate three-dimensional {sup 166}Ho-PLLA-MS activity distributions, enabling localized intrahepatic radiation-absorbed dose estimation by convolution with a {sup 166}Ho dose point-kernel for liver radioembolization treatment optimization and evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recommended Parameter Values for GENII Modeling of Radionuclides in Routine Air and Water Releases

The GENII v2 code is used to estimate dose to individuals or populations from the release of radioactive materials into air or water. Numerous parameter values are required for input into this code. User-defined parameters cover the spectrum from chemical data, meteorological data, agricultural data, and behavioral data. This document is a summary of parameter values that reflect conditions in the United States. Reasonable regional and age-dependent data is summarized. Data availability and quality varies. The set of parameters described address scenarios for chronic air emissions or chronic releases to public waterways. Considerations for the special tritium and carbon-14 models are briefly addressed. GENIIv2.10.0 is the current software version that this document supports.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-753: Three-Dimensional Dose Distributions of Incident Proton Particle in the Polymer Gel Dosimeter and the Radiochromic Gel Dosimeter: A Simulation Study with MCNP Code

Purpose: The purpose of this study is to estimate the three-dimensional dose distributions in the polymer and the radiochromic gel dosimeter, and to identify the detectability of both gel dosimeters by comparing with the water phantom in case of irradiating the proton particles. Methods: The normoxic polymer gel and the LCV micelle radiochromic gel were used in this study. The densities of polymer and the radiochromic gel dosimeter were 1.024 and 1.005 g/cm{sup 3}, respectively. The dose distributions of protons in the polymer and radiochromic gel were simulated using Monte Carlo radiation transport code (MCNPX, Los Alamos National Laboratory). The shape of phantom irradiated by proton particles was a hexahedron with the dimension of 12.4 × 12.4 × 15.0 cm{sup 3}. The energies of proton beam were 50, 80, and 140 MeV energies were directed to top of the surface of phantom. The cross-sectional view of proton dose distribution in both gel dosimeters was estimated with the water phantom and evaluated by the gamma evaluation method. In addition, the absorbed dose(Gy) was also calculated for evaluating the proton detectability. Results: The evaluation results show that dose distributions in both gel dosimeters at intermediated section and Bragg-peak region are similar with that of the water phantom. At entrance section, however, inconsistencies of dose distribution are represented, compared with water. The relative absorbed doses in radiochromic and polymer gel dosimeter were represented to be 0.47 % and 2.26 % difference, respectively. These results show that the radiochromic gel dosimeter was better matched than the water phantom in the absorbed dose evaluation. Conclusion: The polymer and the radiochromic gel dosimeter show similar characteristics in dose distributions for the proton beams at intermediate section and Bragg-peak region. Moreover the calculated absorbed dose in both gel dosimeters represents similar tendency by comparing with that in water phantom.

60 APPLIED LIFE SCIENCES↗

SU-F-J-146: Experimental Validation of 6 MV Photon PDD in Parallel Magnetic Field Calculated by EGSnrc

Purpose: Integrated linac-MR systems are uniquely suited for real time tumor tracking during radiation treatment. Understanding the magnetic field dose effects and incorporating them in treatment planning is paramount for linac-MR clinical implementation. We experimentally validated the EGSnrc dose calculations in the presence of a magnetic field parallel to the radiation beam travel. Methods: Two cylindrical bore electromagnets produced a 0.21 T magnetic field parallel to the central axis of a 6 MV photon beam. A parallel plate ion chamber was used to measure the PDD in a polystyrene phantom, placed inside the bore in two setups: phantom top surface coinciding with the magnet bore center (183 cm SSD), and with the magnet bore’s top surface (170 cm SSD). We measured the field of the magnet at several points and included the exact dimensions of the coils to generate a 3D magnetic field map in a finite element model. BEAMnrc and DOSXYZnrc simulated the PDD experiments in parallel magnetic field (i.e. 3D magnetic field included) and with no magnetic field. Results: With the phantom surface at the top of the electromagnet, the surface dose increased by 10% (compared to no-magnetic field), due to electrons being focused by the smaller fringe fields of the electromagnet. With the phantom surface at the bore center, the surface dose increased by 30% since extra 13 cm of air column was in relatively higher magnetic field (>0.13T) in the magnet bore. EGSnrc Monte Carlo code correctly calculated the radiation dose with and without the magnetic field, and all points passed the 2%, 2 mm Gamma criterion when the ion chamber’s entrance window and air cavity were included in the simulated phantom. Conclusion: A parallel magnetic field increases the surface and buildup dose during irradiation. The EGSnrc package can model these magnetic field dose effects accurately. Dr. Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization).

60 APPLIED LIFE SCIENCES↗

SU-E-CAMPUS-I-04: Automatic Skin-Dose Mapping for An Angiographic System with a Region-Of-Interest, High-Resolution Detector

Purpose: Our real-time skin dose tracking system (DTS) has been upgraded to monitor dose for the micro-angiographic fluoroscope (MAF), a high-resolution, small field-of-view x-ray detector. Methods: The MAF has been mounted on a changer on a clinical C-Arm gantry so it can be used interchangeably with the standard flat-panel detector (FPD) during neuro-interventional procedures when high resolution is needed in a region-of-interest. To monitor patient skin dose when using the MAF, our DTS has been modified to automatically account for the change in scatter for the very small MAF FOV and to provide separated dose distributions for each detector. The DTS is able to provide a color-coded mapping of the cumulative skin dose on a 3D graphic model of the patient. To determine the correct entrance skin exposure to be applied by the DTS, a correction factor was determined by measuring the exposure at the entrance surface of a skull phantom with an ionization chamber as a function of entrance beam size for various beam filters and kVps. Entrance exposure measurements included primary radiation, patient backscatter and table forward scatter. To allow separation of the dose from each detector, a parameter log is kept that allows a replay of the procedure exposure events and recalculation of the dose components.The graphic display can then be constructed showing the dose distribution from the MAF and FPD separately or together. Results: The DTS is able to provide separate displays of dose for the MAF and FPD with field-size specific scatter corrections. These measured corrections change from about 49% down to 10% when changing from the FPD to the MAF. Conclusion: The upgraded DTS allows identification of the patient skin dose delivered when using each detector in order to achieve improved dose management as well as to facilitate peak skin-dose reduction through dose spreading. Research supported in part by Toshiba Medical Systems Corporation and NIH Grants R43FD0158401, R44FD0158402 and R01EB002873.

60 APPLIED LIFE SCIENCES↗

Estimation of dose delivered to accelerator devices from stripping of 18.5 MeV/n 238 U ions using the FLUKA code

In Korea, a heavy ion accelerator facility (RAON) has been designed for production of rare isotopes. The 90° bending section of this accelerator includes a 1.3-μm-carbon stripper followed by two dipole magnets and other devices. An incident beam is 18.5 MeV/n 238 U 33+,34+ ions passing through the carbon stripper at the beginning of the section. The two dipoles are tuned to transport 238 U ions with specific charge states of 77+, 78+, 79+, 80+ and 81+. Then other ions will be deflected at the bends and cause beam losses. These beam losses are a concern to the devices of transport/beam line. The absorbed dose in devices and prompt dose in the tunnel were calculated using the FLUKA code in order to estimate radiation damage of such devices located at the 90° bending section and for the radiation protection. A novel method to transport multi-charged 238 U ions beam was applied in the FLUKA code by using charge distribution of 238 U ions after the stripper obtained from LISE++ code. The calculated results showed that the absorbed dose in the devices is influenced by the geometrical arrangement. The maximum dose was observed at the coils of first, second, fourth and fifth quadruples placed after first dipole magnet. The integrated doses for 30 years of operation with 9.5 pμA 238 U ions were about 2 MGy for those quadrupoles. In conclusion, the protection of devices particularly, quadruples would be necessary to reduce the damage to devices. Furthermore, results showed that the prompt radiation penetrated within the first 60 - 120 cm of concrete.

43 PARTICLE ACCELERATORS↗

User's Manual for RESRAD-BUILD Code Version 4: Vol. 2 - User's Guide for RESRAD-BUILD Code Version 4

The RESRAD-BUILD computer code is designed to assess radiological doses to individuals who live or work in a building contaminated with radioactive material. The code is equipped with a user-friendly interface that has many features to facilitate using the computer code and understanding the results. The design of the interface provides various options, from entering data and performing calculations to displaying calculation results. General and context-specific help are available, providing information on editing and viewing the radionuclide database, the definitions of input parameters and their use in the calculations, and the selection of the calculation results for placement into other applications. Two types of sensitivity analysis are supported by the code, i.e., deterministic and probabilistic, that can be used to study the influence of input parameters on the calculation results. This user’s guide provides instructions to help users on how to install the RESRAD-BUILD code, navigate the interface, and use the various features to set up a dose/risk analysis and to view/print the results in text and graphical outputs.

61 RADIATION PROTECTION AND DOSIMETRY↗

ARCHER{sub RT} – A GPU-based and photon-electron coupled Monte Carlo dose computing engine for radiation therapy: Software development and application to helical tomotherapy

Purpose: Using the graphical processing units (GPU) hardware technology, an extremely fast Monte Carlo (MC) code ARCHER{sub RT} is developed for radiation dose calculations in radiation therapy. This paper describes the detailed software development and testing for three clinical TomoTherapy® cases: the prostate, lung, and head and neck. Methods: To obtain clinically relevant dose distributions, phase space files (PSFs) created from optimized radiation therapy treatment plan fluence maps were used as the input to ARCHER{sub RT}. Patient-specific phantoms were constructed from patient CT images. Batch simulations were employed to facilitate the time-consuming task of loading large PSFs, and to improve the estimation of statistical uncertainty. Furthermore, two different Woodcock tracking algorithms were implemented and their relative performance was compared. The dose curves of an Elekta accelerator PSF incident on a homogeneous water phantom were benchmarked against DOSXYZnrc. For each of the treatment cases, dose volume histograms and isodose maps were produced from ARCHER{sub RT} and the general-purpose code, GEANT4. The gamma index analysis was performed to evaluate the similarity of voxel doses obtained from these two codes. The hardware accelerators used in this study are one NVIDIA K20 GPU, one NVIDIA K40 GPU, and six NVIDIA M2090 GPUs. In addition, to make a fairer comparison of the CPU and GPU performance, a multithreaded CPU code was developed using OpenMP and tested on an Intel E5-2620 CPU. Results: For the water phantom, the depth dose curve and dose profiles from ARCHER{sub RT} agree well with DOSXYZnrc. For clinical cases, results from ARCHER{sub RT} are compared with those from GEANT4 and good agreement is observed. Gamma index test is performed for voxels whose dose is greater than 10% of maximum dose. For 2%/2mm criteria, the passing rates for the prostate, lung case, and head and neck cases are 99.7%, 98.5%, and 97.2%, respectively. Due to specific architecture of GPU, modified Woodcock tracking algorithm performed inferior to the original one. ARCHER{sub RT} achieves a fast speed for PSF-based dose calculations. With a single M2090 card, the simulations cost about 60, 50, 80 s for three cases, respectively, with the 1% statistical error in the PTV. Using the latest K40 card, the simulations are 1.7–1.8 times faster. More impressively, six M2090 cards could finish the simulations in 8.9–13.4 s. For comparison, the same simulations on Intel E5-2620 (12 hyperthreading) cost about 500–800 s. Conclusions: ARCHER{sub RT} was developed successfully to perform fast and accurate MC dose calculation for radiotherapy using PSFs and patient CT phantoms.

60 APPLIED LIFE SCIENCES↗

Kilovoltage Imaging Doses in the Radiotherapy of Pediatric Cancer Patients

Purpose: To investigate doses induced by kilovoltage cone-beam computed tomography (kVCBCT) to pediatric cancer patients undergoing radiotherapy, as well as strategies for dose reduction. Methods and Materials: An EGS4 Monte Carlo code was used to calculate three-dimensional dose deposition due to kVCBCT on 4 pediatric cancer patients. Absorbed doses to various organs were analyzed for both half-fan and full-fan modes. Clinical conditions, such as distance from organ at risk (OAR) to CBCT field border, kV peak energy, and testicular shielding, were studied. Results: The mean doses induced by one CBCT scan operated at 125 kV in half-fan mode to testes, liver, kidneys, femoral heads, spinal cord, brain, eyes, lens, and optical nerves were 2.9, 4.7, 7.7, 10.5, 8.8, 7.6, 7.7, 7.8, and 7.2 cGy, respectively. Increasing the distances from OARs to CBCT field border greatly reduced the doses to OARs, ranging from 33% reduction for spinal cord to 2300% reduction for testes. As photon beam energy increased from 60 to 125 kV, the dose increase due to kVCBCT ranged from 170% for lens to 460% for brain and spinal cord. A testicular shielding made of 1-cm cerrobend could reduce CBCT doses down to 31%, 51%, 68%, and 82%, respectively, for 60, 80, 100, and 125 kV when the testes lay within the CBCT field. Conclusions: Generally speaking, kVCBCT deposits much larger doses to critical structures in children than in adults, usually by a factor of 2 to 3. Increasing the distances from OARs to CBCT field border greatly reduces doses to OARs. Depending on OARs, kVCBCT-induced doses increase linearly or exponentially with photon beam energy. Testicular shielding works more efficiently at lower kV energies. On the basis of our study, it is essential to choose an appropriate scanning protocol when kVCBCT is applied to pediatric cancer patients routinely.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detailed SCALE Dose Rate Evaluations for a Consolidated Interim Spent Nuclear Fuel Storage Facility

This paper presents a confirmatory dose rate calculation for a proposed consolidated interim spent nuclear fuel (SNF) storage facility (CISF). The proposed CISF was modeled in detail using SCALE 6.2.1 to determine the radiation dose map of the surrounding areas of the facility and determine the location of the controlled area boundary based on 10 CFR 72.104 requirements. The spatial dose rate distribution was determined as the total dose rate contributions by each of the 467 storage casks comprising the CISF. A rectangular boundary outside of which no dose rate exceeds 25 mrem/yr has the dimensions of 1.25 km x 1.25 km. It denotes the smallest rectangle that could serve as the controlled area boundary. The results (dose map) show the unique capability of the SCALE code system for a high-resolution radiation dose simulation of a large SNF storage facility.

Radulescu, Georgeta↗

SU-C-BRC-05: Monte Carlo Calculations to Establish a Simple Relation of Backscatter Dose Enhancement Around High-Z Dental Alloy to Its Atomic Number

Purpose: To establish a simple relation of backscatter dose enhancement around a high-Z dental alloy in head and neck radiation therapy to its average atomic number based on Monte Carlo calculations. Methods: The PHITS Monte Carlo code was used to calculate dose enhancement, which is quantified by the backscatter dose factor (BSDF). The accuracy of the beam modeling with PHITS was verified by comparing with basic measured data namely PDDs and dose profiles. In the simulation, a high-Z alloy of 1 cm cube was embedded into a tough water phantom irradiated by a 6-MV (nominal) X-ray beam of 10 cm × 10 cm field size of Novalis TX (Brainlab). The ten different materials of high-Z alloys (Al, Ti, Cu, Ag, Au-Pd-Ag, I, Ba, W, Au, Pb) were considered. The accuracy of calculated BSDF was verified by comparing with measured data by Gafchromic EBT3 films placed at from 0 to 10 mm away from a high-Z alloy (Au-Pd-Ag). We derived an approximate equation to determine the relation of BSDF and range of backscatter to average atomic number of high-Z alloy. Results: The calculated BSDF showed excellent agreement with measured one by Gafchromic EBT3 films at from 0 to 10 mm away from the high-Z alloy. We found the simple linear relation of BSDF and range of backscatter to average atomic number of dental alloys. The latter relation was proven by the fact that energy spectrum of backscatter electrons strongly depend on average atomic number. Conclusion: We found a simple relation of backscatter dose enhancement around high-Z alloys to its average atomic number based on Monte Carlo calculations. This work provides a simple and useful method to estimate backscatter dose enhancement from dental alloys and corresponding optimal thickness of dental spacer to prevent mucositis effectively.

60 APPLIED LIFE SCIENCES↗

Estimation of Effective Doses for Radiation Cancer Risks on ISS, Lunar, and Mars Missions with Space Radiation Measurement

Radiation protection practices define the effective dose as a weighted sum of equivalent dose over major sites for radiation cancer risks. Since a crew personnel dosimeter does not make direct measurement of effective dose, it has been estimated with skin-dose measurements and radiation transport codes for ISS and STS missions. The Phantom Torso Experiment (PTE) of NASA s Operational Radiation Protection Program has provided the actual flight measurements of active and passive dosimeters which were placed throughout the phantom on STS-91 mission for 10 days and on ISS Increment 2 mission. For the PTE, the variation in organ doses, which is resulted by the absorption and the changes in radiation quality with tissue shielding, was considered by measuring doses at many tissue sites and at several critical body organs including brain, colon, heart, stomach, thyroid, and skins. These measurements have been compared with the organ dose calculations obtained from the transport models. Active TEPC measurements of lineal energy spectra at the surface of the PTE also provided the direct comparison of galactic cosmic ray (GCR) or trapped proton dose and dose equivalent. It is shown that orienting the phantom body as actual in ISS is needed for the direct comparison of the transport models to the ISS data. One of the most important observations for organ dose equivalent of effective dose estimates on ISS is the fractional contribution from trapped protons and GCR. We show that for most organs over 80% is from GCR. The improved estimation of effective doses for radiation cancer risks will be made with the resultant tissue weighting factors and the modified codes.

Kim, M.Y.↗

PNNL Dose-per-Unit-Release Factors for Calculating Radionuclide Emissions Potential-to-Emit Doses

Revised PNNL-Richland campus dose-per-unit release factors based on the Environmental Protection Agency code CAP88-PC Version 4.1.1 code are provided. In addition to maximum receptor dose factors, maximum air concentration dose factors are provided. The PNNL-Sequim campus dose-per-unit release factors are included, as well, based on the Environmental Protection Agency code COMPLY Version 1.7.1.

40 CFR 61 Subpart H↗

Breast dosimetry in transverse and longitudinal field MRI-Linac radiotherapy systems

Purpose: In the framework of developing the integration of a MRI-Linac system, configurations of MRI-Linac units were simulated in order to improve the dose distribution in tangential breast radiotherapy using transverse and longitudinal magnetic field geometries of Lorentz force for both medial and lateral tangential fields. Methods: In this work, the GEANT4 Monte Carlo (MC) code was utilized to compare dose distributions in breast radiotherapy for Linac-MR systems in the transverse and longitudinal geometries within humanoid phantoms across a range of magnetic field strengths of 0.5 and 1.5 T. The dose increment due to scattering from the coils was investigated for both geometries as well. Computed tomography images of two patients were used for MC simulations. One patient had intact breast while the other was mastectomized. In the simulations, planning and methods of chest wall irradiation were similar to the actual clinical planning. Results: In a longitudinal geometry, the magnetic field is shown to restrict the lateral spread of secondary electrons to the lung, heart, and contralateral organs, which reduced the mean dose of the ipsilateral lung and heart by means of 17.2% and 6% at 1.5 T, respectively. The transverse configuration exhibits a significant increase in tissue interface effects, which increased dose buildup in the entrance regions of the lateral and medial tangent beams to the planning target volume (PTV) and improved dose homogeneity within the PTV. The improved relative average homogeneity index for two patients to the PTV at magnetic field strength of 1.5 T with respect to no magnetic field case evaluated was 11.79% and 34.45% in the LRBP and TRBP geometries, respectively. In both geometries, the simulations show significant mean dose reductions in the contralateral breast and chest wall skin, respectively, by a mean of 16.6% and 24.9% at 0.5 T and 17.2% and 28.1% at 1.5 T in the transverse geometry, and 10.56% and 14.6% at 0.5 T and 11.3% and 16.3% at 1.5 T in the longitudinal geometry. Considering the scattered photons which reflected from the coils, the average relative dose of each voxel is slightly increased by 0.53% and 0.32% in the LRBP and TRBP geometries, respectively. Conclusions: Orienting the B0 magnetic field parallel to the photon beam axis, LRBP geometry, tends to restrict the radial spread of secondary electrons which resulted in dose reduction to the lung. Dosimetry issues observed in both Linac-MR geometries, such as changes to the lateral dose distribution, significantly exhibited dose reduction in the contralateral organs on a representative breast plan. Further, the results show sharper edge dose volume histogram curves at 1.5 T for both geometries, especially in the LRBP configuration.

60 APPLIED LIFE SCIENCES↗

Comparison of dose estimates using the buildup-factor method and a Baryon transport code (BRYNTRN) with Monte Carlo results

Continuing efforts toward validating the buildup factor method and the BRYNTRN code, which use the deterministic approach in solving radiation transport problems and are the candidate engineering tools in space radiation shielding analyses, are presented. A simplified theory of proton buildup factors assuming no neutron coupling is derived to verify a previously chosen form for parameterizing the dose conversion factor that includes the secondary particle buildup effect. Estimates of dose in tissue made by the two deterministic approaches and the Monte Carlo method are intercompared for cases with various thicknesses of shields and various types of proton spectra. The results are found to be in reasonable agreement but with some overestimation by the buildup factor method when the effect of neutron production in the shield is significant. Future improvement to include neutron coupling in the buildup factor theory is suggested to alleviate this shortcoming. Impressive agreement for individual components of doses, such as those from the secondaries and heavy particle recoils, are obtained between BRYNTRN and Monte Carlo results.

Shinn, Judy L.↗

Comparison of dose calculation methods for brachytherapy of intraocular tumors

Purpose: To investigate dosimetric differences among several clinical treatment planning systems (TPS) and Monte Carlo (MC) codes for brachytherapy of intraocular tumors using {sup 125}I or {sup 103}Pd plaques, and to evaluate the impact on the prescription dose of the adoption of MC codes and certain versions of a TPS (Plaque Simulator with optional modules). Methods: Three clinical brachytherapy TPS capable of intraocular brachytherapy treatment planning and two MC codes were compared. The TPS investigated were Pinnacle v8.0dp1, BrachyVision v8.1, and Plaque Simulator v5.3.9, all of which use the AAPM TG-43 formalism in water. The Plaque Simulator software can also handle some correction factors from MC simulations. The MC codes used are MCNP5 v1.40 and BrachyDose/EGSnrc. Using these TPS and MC codes, three types of calculations were performed: homogeneous medium with point sources (for the TPS only, using the 1D TG-43 dose calculation formalism); homogeneous medium with line sources (TPS with 2D TG-43 dose calculation formalism and MC codes); and plaque heterogeneity-corrected line sources (Plaque Simulator with modified 2D TG-43 dose calculation formalism and MC codes). Comparisons were made of doses calculated at points-of-interest on the plaque central-axis and at off-axis points of clinical interest within a standardized model of the right eye. Results: For the homogeneous water medium case, agreement was within {approx}2% for the point- and line-source models when comparing between TPS and between TPS and MC codes, respectively. For the heterogeneous medium case, dose differences (as calculated using the MC codes and Plaque Simulator) differ by up to 37% on the central-axis in comparison to the homogeneous water calculations. A prescription dose of 85 Gy at 5 mm depth based on calculations in a homogeneous medium delivers 76 Gy and 67 Gy for specific {sup 125}I and {sup 103}Pd sources, respectively, when accounting for COMS-plaque heterogeneities. For off-axis points-of-interest, dose differences approached factors of 7 and 12 at some positions for {sup 125}I and {sup 103}Pd, respectively. There was good agreement ({approx}3%) among MC codes and Plaque Simulator results when appropriate parameters calculated using MC codes were input into Plaque Simulator. Plaque Simulator and MC users are perhaps at risk of overdosing patients up to 20% if heterogeneity corrections are used and the prescribed dose is not modified appropriately. Conclusions: Agreement within 2% was observed among conventional brachytherapy TPS and MC codes for intraocular brachytherapy dose calculations in a homogeneous water environment. In general, the magnitude of dose errors incurred by ignoring the effect of the plaque backing and Silastic insert (i.e., by using the TG-43 approach) increased with distance from the plaque's central-axis. Considering the presence of material heterogeneities in a typical eye plaque, the best method in this study for dose calculations is a verified MC simulation.

60 APPLIED LIFE SCIENCES↗