Search NASA⌕ Search

SEARCH · Search NASA

Results for “Droplet size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

TPSAS-NF1676L-28148-DND

Currently, ocean carbon biomass is estimated from ocean color measurements primarily through particulate backscatter coefficients (bbp). Small non-algal particles contribute significantly to bbp due to the fact that small particles scatter more isotropically while bigger particles scatter mostly in the forward direction. CALIPSO’s ocean subsurface cross polarization measurements (Figure 1) are not sensitive to small particles far less than 2 microns in size since these particles rarely cause depolarization. Thus, cross polarization backscatter is contributed mostly by larger, depolarizing phytoplankton particles. This is why CALIPSO’s cross polarization has much larger contrasts comparing with MODIS reflectance (CALIPSO cross polarization is very weak in Gyres and much stronger in high latitudes, See Figure 1). CALIPSO cross-polarization measurements in the Southern Oceans also suggest that water cloud droplet number concentration covaries with phytoplankton carbon biomass (Figure 2), but it has less correlation with particulate organic carbon (POC) (Figure 2) and chlorophyll concentration. The study also agrees with water cloud droplet size retrieved from Parasol’s polarization measurements.

Yongxiang Hu↗

Automatic holographic droplet analysis for liquid fuel sprays

The basic scheme for automated holographic analysis involves an optical system for reconstruction of the three dimensional real image of the droplet field, a spatial scanning system to transport a digitizing X-y image sensor through the real image, and processing algorithms for droplet recognition which establish the droplet sizes and positions. The hardware for system demonstrated includes the expanded and collimated beam from a 5 mW helium-neon laser for hologram reconstruction, an imaging lens for magnification of the real image field, and a video camera and digitizer providing 512-by-512 pixel resolution with 8-bit digitization. A mechanical stage is used to scan the hologram in three dimensional space, maintaining constant image magnification. A test droplet hologram is used for development and testing of the image processing algorithms.

Stanton, A. C.↗

A Study of Large Droplet Ice Accretion in the NASA Lewis IRT at Near-Freezing Conditions

Results of experiments designed to determine the effects of large droplet ice accretion on a NACA 23012 wing section are presented. Using primarily an icing condition with a median volumetric diameter droplet size of 160 micron and a liquid water content of 0.82 grams per cubic meter, the effects of various air temperatures, angles of attack, and de-icer boot cycle interval times on ice accretion were studied. Measurements of aerodynamic performance penalties due to the ice accretions were made. Results were also compared with similar tests conducted with a Twin Otter wing section in Part 1 of this study. The form of the ice from the large droplet cloud varied as a function of air total temperature; particularly at the near-freezing temperatures of 28 F to 34 F. Changing boot cycle interval time did not prevent formation of an ice ridge. The most detrimental aerodynamic effects occurred at an air total temperature of 28 F.

Addy, Harold E., Jr.↗

Microgravity combustion of isolated n-decane and n-heptane droplets

This paper presents recent experimental results on n-heptane droplet combustion from a 5.0 second Zero-Gravity Facility. For these experiments, droplet sizes from 1 mm to 1.75 mm were studied, oxygen mole fractions in nitrogen ranged from 12 to 21 percent, and the pressure was varied from 0.25 to 1 atm. Disruptive burning mechanisms were observed in some of the experiments conducted in air environments. However, this behavior was inhibited by reducing the oxygen concentration and/or the system pressure. The above results suggest that combinations of lower oxygen indices and reduced ambient pressures are important to reducing the effects of sooting on droplet vaporization-rates.

Choi, Mun Y.↗

Combustion Instability Analysis and the Effects of Drop Size on Acoustic Driving Rocket Flow

High frequency combustion instability, the most destructive kind, is generally solved on a per engine basis. The instability often is the result of compounding acoustic oscillations, usually from the propellant combustion itself. To counteract the instability the chamber geometry can be changed and/or the method of propellant injection can be altered. This experiment will alter the chamber dimensions slightly; using a cylindrical shape of constant diameter and the length will be varied from six to twelve inches in three-inch increments. The main flowfield will be the products of a high OF hydrogen/oxygen flow. The liquid fuel will be injected into this flowfield using a modulated injector. It will allow for varied droplet size, feed rate, spray pattern, and location for the mixture within the chamber. The response will be deduced from the chamber pressure oscillations.

Harper, Brent↗

Methanol Droplet Combustion in Oxygen-Inert Environments in Microgravity

The Flame Extinguishment (FLEX) experiment that is currently underway in the Combustion Integrated Rack facility onboard the International Space Station is aimed at understanding the effects of inert diluents on the flammability of condensed phase fuels. To this end, droplets of various fuels, including alkanes and alcohols, are burned in a quiescent microgravity environment with varying amounts of oxygen and inert diluents to determine the limiting oxygen index (LOI) for these fuels. In this study we report experimental observations of methanol droplets burning in oxygen-nitrogen-carbon dioxide and oxygen-nitrogen-helium gas mixtures at 0.7 and 1 atmospheric pressures. The initial droplet size varied between approximately 1.5 mm and 4 mm to capture both diffusive extinction brought about by insufficient residence time at the flame and radiative extinction caused by excessive heat loss from the flame zone. The ambient oxygen concentration varied from a high value of 30% by volume to as low as 12%, approaching the limiting oxygen index for the fuel. The inert dilution by carbon dioxide and helium varied over a range of 0% to 70% by volume. In these experiments, both freely floated and tethered droplets were ignited using symmetrically opposed hot-wire igniters and the burning histories were recorded onboard using digital cameras, downlinked later to the ground for analysis. The digital images yielded droplet and flame diameters as functions of time and subsequently droplet burning rate, flame standoff ratio, and initial and extinction droplet diameters. Simplified theoretical models correlate the measured burning rate constant and the flame standoff ratio reasonably well. An activation energy asymptotic theory accounting for time-dependent water dissolution or evaporation from the droplet is shown to predict the measured diffusive extinction conditions well. The experiments also show that the limiting oxygen index for methanol in these diluent gases is around 12% to 13% oxygen by volume.

Nayagam, Vedha↗

Fluid Flow in An Evaporating Droplet

Droplet evaporation is a common phenomenon in everyday life. For example, when a droplet of coffee or salt solution is dropped onto a surface and the droplet dries out, a ring of coffee or salt particles is left on the surface. This phenomenon exists not only in everyday life, but also in many practical industrial processes and scientific research and could also be used to assist in DNA sequence analysis, if the flow field in the droplet produced by the evaporation could be understood and predicted in detail. In order to measure the fluid flow in a droplet, small particles can be suspended into the fluid as tracers. From the ratio of gravitational force to Brownian force a(exp 4)(delta rho)(g)/k(sub B)T, we find that particle's tendency to settle is proportional to a(exp 4) (a is particle radius). So, to keep the particles from settling, the droplet size should be chosen to be in a range 0.1 -1.0 microns in experiments. For such small particles, the Brownian force will affect the motion of the particle preventing accurate measurement of the flow field. This problem could be overcome by using larger particles as tracers to measure fluid flow under microgravity since the gravitational acceleration g is then very small. For larger particles, Brownian force would hardly affect the motion of the particles. Therefore, accurate flow field could be determined from experiments in microgravity. In this paper, we will investigate the fluid flow in an evaporating droplet under normal gravity, and compare experiments to theories. Then, we will present our ideas about the experimental measurement of fluid flow in an evaporating droplet under microgravity.

Hu, H.↗

Combustion characteristics in the transition region of liquid fuel sprays

A number of important effects have been observed in the droplet size transition region in spray combustion systems. In this region, where the mechanism of flame propagation is transformed from diffusive to premixed dominated combustion, the following effects have been observed: (1) maxima in burning velocity; (2) extension of flammability limits; (3) minima in ignition energy; and (4) minima in NOx formation. A monodisperse aerosol generator has been used to form and deliver a well controlled liquid fuel spray to the combustion test section where measurements of ignition energy have been made. The ignition studies were performed on monodisperse n-heptane sprays at atmospheric pressure over a range of equivalence ratios and droplet diameters. A capacitive discharge spark ignition system was used as the ignition source, providing independent control of spark energy and duration. Preliminary measurements were made to optimize spark duration and spark gap, optimum conditions being those at which the maximum frequency or probability of ignition was observed. Using the optimum electrode spacing and spark duration, the frequency of ignition was determined as a function of spark energy for three overall equivalence ratios (0.6, 0.8, and 1.0) and for initial droplet diameters of 25, 40, 50, 60, and 70 micro m.

Cernansky, N. P.↗

A Near-Global Survey of Cirrus Particle Size Using ISCCP

Cirrus is the most frequently occurring and widely distributed cloud type. The average annual frequency of occurrence for cirrus is 34% and its global coverage is about 20-30% (Warren et al. 1985). It strongly influences weather and climate processes through its effects on the radiation budget of the earth and the atmosphere (Liou 1986). Microphysics of cirrus is a critical component in understanding cloud-climate radiative interactions. For example, ice water content feedback is positive from a 1-D model study. But the feedback is substantially reduced upon the inclusion of small ice crystals (Sinha and Shine 1994). Due to the complexity caused by the non-spherical shape of ice crystals in cirrus, retrievals of cirrus properties are difficult. In recent years, advances have been made both in models and in case studies (e.g., Takano and Liou 1989, Young et al. 1994), but no global scale survey has been conducted. Similar to our previous near-global survey of droplet sizes of liquid water clouds (Han et al. 1994), a survey of cirrus ice crystal sizes is conducted over both continental and oceanic areas. We describe a method for retrieving cirrus particle size information on a near-global scale 50 deg S to 50 deg N using currently available satellite data from ISCCP. To retrieve cirrus particle size, we use a radiative transfer model that includes all major absorbing gases and cloud scattering/absorption to compute synthetic radiances as a function of satellite viewing geometry. Ice crystal shapes are assumed to be hexagonal columns and plates. The model results have been validated against clear sky observations and are consistent with the observed radiance range under cloudy conditions.

Han, Qingyuan↗

Containerless processing of undercooled melts

Containerless drop tube processing allows for significant levels of liquid undercooling through control of parameters such as sample size, surface coating and cooling rate. A laboratory scale (3 m) drop tube has been developed which allows the undercooling and solidification behavior of powder samples to be evaluated under low gravity free-fall conditions. The level of undercooling obtained in an InSb-Sb eutectic alloy has been evaluated by comparing the eutectic spacing in drop tube samples with a spacing/undercooling relationship established using thermal analysis techniques. Undercoolings of 0.17 and 0.23 T(e) were produced by processing under vacuum and He gas conditions respectively. Alternatively, the formation of an amorphous phase in a Ni-Nb eutectic alloy indicates that undercooling levels of approximately 500 C were obtained by drop tube processing. The influence of droplet size and gas environment on undercooling behavior in the Ni-Nb eutectic was evaluated through their effect on the amorphous/crystalline phase ratio. To supplement the structural analysis, heat flow modeling has been developed to describe the undercooling history during drop tube processing, and the model has been tested experimentally.

Shong, D. S.↗

Statistical Analysis of Instantaneous Frequency Scaling Factor as Derived From Optical Disdrometer Measurements At KQ Bands

The rain rate data and statistics of a location are often used in conjunction with models to predict rain attenuation. However, the true attenuation is a function not only of rain rate, but also of the drop size distribution (DSD). Generally, models utilize an average drop size distribution (Laws and Parsons or Marshall and Palmer. However, individual rain events may deviate from these models significantly if their DSD is not well approximated by the average. Therefore, characterizing the relationship between the DSD and attenuation is valuable in improving modeled predictions of rain attenuation statistics. The DSD may also be used to derive the instantaneous frequency scaling factor and thus validate frequency scaling models. Since June of 2014, NASA Glenn Research Center (GRC) and the Politecnico di Milano (POLIMI) have jointly conducted a propagation study in Milan, Italy utilizing the 20 and 40 GHz beacon signals of the Alphasat TDP#5 Aldo Paraboni payload. The Ka- and Q-band beacon receivers provide a direct measurement of the signal attenuation while concurrent weather instrumentation provides measurements of the atmospheric conditions at the receiver. Among these instruments is a Thies Clima Laser Precipitation Monitor (optical disdrometer) which yields droplet size distributions (DSD); this DSD information can be used to derive a scaling factor that scales the measured 20 GHz data to expected 40 GHz attenuation. Given the capability to both predict and directly observe 40 GHz attenuation, this site is uniquely situated to assess and characterize such predictions. Previous work using this data has examined the relationship between the measured drop-size distribution and the measured attenuation of the link]. The focus of this paper now turns to a deeper analysis of the scaling factor, including the prediction error as a function of attenuation level, correlation between the scaling factor and the rain rate, and the temporal variability of the drop size distribution both within a given rain event and across different varieties of rain events. Index Terms-drop size distribution, frequency scaling, propagation losses, radiowave propagation.

Statistics↗

Statistical Analysis of Instantaneous Frequency Scaling Factor as Derived From Optical Disdrometer Measurements At KQ Bands

The rain rate data and statistics of a location are often used in conjunction with models to predict rain attenuation. However, the true attenuation is a function not only of rain rate, but also of the drop size distribution (DSD). Generally, models utilize an average drop size distribution (Laws and Parsons or Marshall and Palmer [1]). However, individual rain events may deviate from these models significantly if their DSD is not well approximated by the average. Therefore, characterizing the relationship between the DSD and attenuation is valuable in improving modeled predictions of rain attenuation statistics. The DSD may also be used to derive the instantaneous frequency scaling factor and thus validate frequency scaling models. Since June of 2014, NASA Glenn Research Center (GRC) and the Politecnico di Milano (POLIMI) have jointly conducted a propagation study in Milan, Italy utilizing the 20 and 40 GHz beacon signals of the Alphasat TDP#5 Aldo Paraboni payload. The Ka- and Q-band beacon receivers provide a direct measurement of the signal attenuation while concurrent weather instrumentation provides measurements of the atmospheric conditions at the receiver. Among these instruments is a Thies Clima Laser Precipitation Monitor (optical disdrometer) which yields droplet size distributions (DSD); this DSD information can be used to derive a scaling factor that scales the measured 20 GHz data to expected 40 GHz attenuation. Given the capability to both predict and directly observe 40 GHz attenuation, this site is uniquely situated to assess and characterize such predictions. Previous work using this data has examined the relationship between the measured drop-size distribution and the measured attenuation of the link [2]. The focus of this paper now turns to a deeper analysis of the scaling factor, including the prediction error as a function of attenuation level, correlation between the scaling factor and the rain rate, and the temporal variability of the drop size distribution both within a given rain event and across different varieties of rain events. Index Terms-drop size distribution, frequency scaling, propagation losses, radiowave propagation.

Radio Attenuation↗

Test and evaluation of Apollo 14 composite casting demonstration specimens 6, 9, and 12, phase 1

Flight and control specimens 6, 9, and 12 from the Apollo 14 composite casting demonstration were evaluated with respect to the degree of dispersion achieved for mixtures of immiscible materials under one-gravity and low gravity environments. The flight and control capsules 6, 9, and 12 contained paraffin and sodium acetate; paraffin, sodium acetate and argon; and paraffin, sodium acetate and 100 micrometer diameter tungsten microspheres, respectively. The evaluation and documentation utilized photographic and microstructure examinations, density measurements, and droplet size and distribution determinations. In addition, theoretical analyses were performed in order to aid in the understanding of the fluid behavior of the specimens during processing and subsequent solidification. A comparison of evaluated data with the theoretical analyses reveals that although the immiscible materials were uniquely dispersed in a low gravity environment, nonuniform dispersions were obtained primarily due to insufficient initial mixing and an essentially unidirectional thermal gradient during cooldown.

Reger, J. L.↗

Studies of oscillatory combustion and fuel vaporization

Research projects involving oscillatory combustion and fuel vaporization are reported. Comparisons of experimental and theoretical droplet vaporization histories under ambient conditions such that the droplet may approach its thermodynamic critical point are presented. Experimental data on instantaneous heat transfer from a gas to a solid surface under conditions of oscillatory pressure with comparisons to an unsteady one-dimensional model are analyzed. Droplet size and velocity distribution in a spray as obtained by use of a double flash fluorescent method were investigated.

Borman, G. L.↗

Observations on degradation of UV systems on Nimbus spacecraft

Broad band photometer experiments in the 1200 to 3000 A have been operating on Nimbus 3 and 4 since April 1969 for the purpose of determining the nature of variations in the UV solar irradiance. An Ebert-Fastie double monochromator has been measuring the solar irradiance and earth radiance from 2500 to 3400 A for the determination of global atmospheric ozone distributions since April 1970. From prelaunch testing and an evaluation of the flight data it is concluded that the principal source of degradation is probably the spacecraft. The degradation produces a characteristic signal loss and change in angular response of the system which might be explained by micron sized droplets becoming a permanent residue under the influence of solar UV radiation.

Heath, D. F.↗