Assessment of Electrode Contamination Mitigation at 0.5 MA Scale

The Z Machine at Sandia National Laboratories uses current pulses with peaks up to 27 MA to drive target implosions and generate high energy density conditions of interest for stockpile stewardship programs pertinent to the NNSA program portfolio . Physical processes in the region near the Z Machine target create electrode plasmas which seed parasitic current loss that reduce the performance and output of a Z experiment. Electrode surface contaminants (hydrogen, water, hydrocarbons) are thought to be the primary constituent of electrode plasmas which contribute to loss mechanisms. The Sandia team explore d in situ heating and plasma discharge techniques by integrating requisite infrastructure into Sandia's Mykonos LTD accelerator, addressing potential impacts to accelerator operation, and reporting on the impact of these techniques on electrode plasma formation and shot performance. The in situ discharge cleaning utilizes the electrodes of the accelerator to excite an argon-oxygen plasma to sputter and chemically react contaminants from electrode surfaces. Insulating breaks are required to isolate the plasma in electrode regions where loss processes are most likely to occur. The shots on Mykonos validate that these breaks do not perturb experiment performance, reducing the uncertainty on the largest unknown about the in situ cleaning system. Preliminary observations with electrical and optical diagnostics suggest that electrode plasma formation is delayed, and overall inventory has been substantively reduced. In situ heating embeds cartridge heaters into accelerator electrodes and employs a thermal bakeout to rapidly desorb contaminants from electrode surfaces. For the first time, additively manufactured (AM) electrode assemblies were used on a low impedance accelerator to integrate cooling channels and manage thermal gradients. Challenges with poor supplier fabrication to specifications, load alignment, thermal expansion and hardware movement and warpage appears to have introduced large variability in observed loss, though, preventing strong assertions of loss reduction via in situ heating. At this time, an in situ discharge cleaning process offers the lowest risk path to reduce electrode contaminant inventories on Z, though we recommend continuing to develop both approaches. Additional engineering and testing are required to improve the implementation of both systems. .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Eddy Current Model of a Coil Over An Infinite Perfectly Electrical Conductor (PEC) Half-Plane

Eddy current sensors measure the lift-off or distance between the sensor and a conducting surface. They operate on the principle of an alternating current in a conduction coil inducing a magnetic field within the surface. An eddy current is set up in the surface to counter the incident magnetic field which, in turn, sets up a magnetic field which counters that of the coil. This changes the coil impedance which is a function of the lift-off. As the lift-off increases, the effect of the eddy current magnetic field on the coil magnetic field weakens, resulting in a higher inductance and lower resistance. Thus, the lift-off may be derived from an impedance measurement. Dodd and Deeds developed an analytic model for an eddy current sensor coil impedance with an air core which has been implemented in MATLAB. LLNL assembled an eddy current sensor with a mu-metal core for which there is no analytic model. Rather than derive an analytic model which includes the mu-metal core, analytic empirically based functions are derived to map the Dodd and Deeds model to measured inductance and resistance.

42 ENGINEERING↗

Increasing Multilayer Ceramic Capacitor Lifetime With Bipolar Voltage Cycling

Enhancing the lifetime of multilayer ceramic capacitors (MLCCs) is critical in many aerospace, naval, or electrical grid applications, where device failure could lead to catastrophic consequences. The migration of oxygen vacancies from the ceramic to the electrode interface under constant bias is known to reduce the lifetime of oxide-based MLCCs. Bias cycling presents an opportunity to enhance MLCC lifetime by reducing oxygen vacancy migration. The ideal frequency range is expected to lie between frequencies low enough to avoid self-heating but high enough to avoid interfacial defect formation. However, the impact of low-frequency bipolar voltage cycling (BVC) on MLCC degradation mechanisms has not been well studied. This work investigates the impact of periodic BVC on the degradation of MLCCs through highly accelerated lifetime testing (HALT) on X7R capacitors. HALT tests were conducted at 255 °C and 60 V using different switching frequencies: 0 (dc), 0.1, 2.5, and 10 Hz. BVC was found to improve the lifetime of MLCCs compared to dc test conditions. MLCCs tested at 10-Hz BVC showed a 311% increase in average time to failure compared to the dc case. Impedance spectroscopy shows that BVC decreases the rate of resistance degradation within MLCCs, indicating that oxygen vacancy migration to the electrodes is mitigated. The impedance spectra taken on BVC samples highlight how grain boundaries play a vital role in trapping oxygen vacancies. Periodic cycling causes oxygen vacancies to become trapped at grain boundaries, resulting in oxygen vacancies taking longer to reach the electrode interface and thus increasing MLCC lifetime. This work highlights not only how BVC can be used to increase MLCC lifetime but also how periodically cycling MLCCs could increase lifetime in extreme environments, such as at elevated temperatures and electric fields.

Chuong, Kayla Y.↗

A 10-Gb/s Driver/Receiver ASIC and Optical Modules for Particle Physics Experiments

We present the design and test results of a Drivers and Limiting AmplifierS ASIC operating at 10 Gbps (DLAS10) and three Miniature Optical Transmitter/Receiver/Transceiver modules (MTx+, MRx+, and MTRx+) based on DLAS10. DLAS10 can drive two Transmitter Optical Sub-Assemblies (TOSAs) of Vertical Cavity Surface Emitting Lasers (VCSELs), receive the signals from two Receiver Optical Sub-Assemblies (ROSAs) that have no embedded limiting amplifiers, or drive a VCSEL TOSA and receive the signal from a ROSA, respectively. Each channel of DLAS10 consists of an input Continuous Time Linear Equalizer (CTLE), a four-stage limiting amplifier (LA), and an output driver. The LA amplifies the signals of variable levels to a stable swing. The output driver drives VCSELs or impedance-controlled traces. DLAS10 is fabricated in a 65 nm CMOS technology. The die is 1 mm x 1 mm. DLAS10 is packaged in a 4 mm x 4 mm 24-pin quad-flat no-leads (QFN) package. DLAS10 has been tested in MTx+, MRx+, and MTRx+ modules. Both measured optical and electrical eye diagrams pass the 10 Gbps eye mask test. Furthermore, the input electrical sensitivity is 40 mVp-p, while the input optical sensitivity is -12 dBm. The total jitter of MRx+ is 29 ps (P-P) with a random jitter of 1.6 ps (RMS) and a deterministic jitter of 9.9 ps. Each MTx+/MTRx+ module consumes 82 mW/ch and 174 mW/ch, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non‐Linear Kinetics of The Lithium Metal Anode on Li 6 PS 5 Cl at High Current Density: Dendrite Growth and the Role of Lithium Microstructure on Creep

Abstract Interfacial instability, viz., pore formation in the lithium metal anode (LMA) during discharge leading to high impedance, current focusing induced solid–electrolyte (SE) fracture during charging, and formation/behaviour of the solid–electrolyte interphase (SEI), at the anode, is one of the major hurdles in the development of solid‐state batteries (SSBs). Also, understanding cell polarization behaviour at high current density is critical to achieving the goal of fast‐charging battery and electric vehicle. Herein, via in situ electrochemical scanning electron microscopy (SEM) measurements, performed with freshly deposited lithium microelectrodes on transgranularly fractured fresh Li6PS5Cl (LPSCl), the LiǀLPSCl interface kinetics are investigated beyond the linear regime. Even at relatively small overvoltages of a few mV, the LiǀLPSCl interface shows non‐linear kinetics. The interface kinetics possibly involve multiple rate‐limiting processes, i.e., ion transport across the SEI and SE|SEI interfaces, as well as charge transfer across the LiǀSEI interface. The total polarization resistance R P of the microelectrode interface is determined to be ≈ 0.8 Ω cm 2 . It is further shown that the nanocrystalline lithium microstructure can lead to a stable LiǀSE interface via Coble creep along with uniform stripping. Also, spatially resolved lithium deposition, i.e., at grain surface flaws, grain boundaries, and flaw‐free surfaces, indicates exceptionally high mechanical endurance of flaw‐free surfaces toward cathodic load (>150 mA cm −2 ). This highlights the prominent role of surface defects in dendrite growth.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Online Monitoring of Medium Voltage Cable Systems with Spread Spectrum Time Domain and Frequency Domain Reflectometry

In-service failures of wave energy convertor (WEC) cable systems can have a significant cost and power availability impact. Close parallel research 2019 data showed > 1B£ and 9 Terra-Watt-Hours associated with global off-shore wind (OSW) cable failures (Strang-Moran 2020). OSW is a closely related technology but currently is significantly cheaper than WEC technology. For wave energy to compete, the problem of reliable cable transmission must be mitigated. This project develops isolation technology to allow online high frequency reflectometry testing of medium voltage cables (1 to 10 kV and higher) without arcing or damage to the test instrument. Online spread spectrum time domain reflectometry (SSTDR) testing has been established for low voltage cable systems in the aircraft and rail industry and the ability to detect and locate cable flaws of interest is well understood. Extending reflectometry testing to medium voltage systems could enable detection of cable damage before failures occur thereby allowing repair and replacement of damaged cable segments to be scheduled and managed. The seedling project succeeded to pass and receive high frequency SSTDR signals onto a cable up to 1 kV using a parallel trace isolation circuit board that can be connected onto the test cable. The approach used a novel circuit design for which an invention disclosure has been filed. A proposed sapling project would extend the technology toward the higher operating voltages used by WEC systems, thereby enabling online SSTDR cable monitoring. The goal of the seedling project was to extend the capability of the ARENA cable/motor test bed to address medium voltages and to develop a high pass filter isolation architecture to protect the reflectometry instrument from the low frequency (DC – 60 Hz) line voltage while allowing the high frequency diagnostic signal to pass to and from the test instrument to the live line. Initial efforts focused on passive LCR filter circuits to reduce 60 Hz levels below 10 volts from a 10 kV line while allowing the MHz high frequency chirps to pass onto the cables and for mV signals to be detected. We discovered that the parasitic loss behavior of real high voltage components precluded this approach from working. An alternate approach was adapted for the electric field to couple between two parallel traces on a printed circuit board much like a radio-frequency coupler. The challenge here was and is to have the parallel traces close enough to each other to effectively pass the high frequency chirp onto the live line and receive any reflected signal from any encountered impedance change along the cable. This reflected signal will be in the mV range. The traces however must be far enough apart to not allow arcing on the board. A design with 3 mm spacing was determined to allow the high frequency signal to pass onto the live line and receive the mV signal back into the instrument while reducing the 60 Hz voltage amplitude by >80 dB (more than a factor of 10,000) without allowing arcing from across the parallel traces. This was confirmed by simulation and test.

16 TIDAL AND WAVE POWER↗

ESSENCE- A rapid, shear-enhanced, flow-through, capacitive electrochemical platform for rapid detection of biomolecules

The rapid, sensitive, and selective detection of target analytes using electrochemical sensors are challenging. ESSENCE, a new Electrochemical Sensor that uses a Shear-Enhanced, flowthrough Nanoporous Capacitive Electrode, overcomes current electrochemical sensors' response limitations, selectivity, and sensitivity limitations. ESSENCE is a microfluidic channel packed with transducer material sandwiched by a top and bottom microelectrode. The room-temperature instrument less integration process allows the switch of the transducer materials to make up the porous electrode without modifying the electrode architecture or device protocol. ESSENCE can be used to detect both biomolecules and small molecules by simply changing the packed transducer material. Electron microscopy results confirm the high porosity. In conjunction with the non-planar interdigitated electrode, the packed transducer material results in a flow-through porous electrode. Electron microscopy results confirm the high porosity. The enhanced shear forces and increased convective fluxes disrupt the electric double layer's (EDL) diffusive process in ESSENCE. This disruption migrates the EDL to high MHz frequency allowing the capture signal to be measured at around 100 kHz, significantly improving device timing (rapid detection) with a low signal-to-noise ratio. The device’s unique architecture allows us multiple configuration modes for measuring the impedance signal. This allows us to use highly conductive materials like carbon nanotubes. We show that by combining single-walled carbon nanotubes as transducer material with appropriate capture probes, NP-µIDE has high selectivity and sensitivity for DNA (fM sensitivity, selective against non-target DNA), breast cancer biomarker proteins (p53, pg/L sensitivity, selective against non-target HER2).

Cheng, Yu-Hsuan↗

Exploring the Effectiveness of Carbon Cloth Electrodes for All-Vanadium Redox Flow Batteries

Vanadium redox flow batteries (VRFBs) have shown to be a promising technology for integrating intermittent renewable energy sources into the existing electrical grid. Incorporation of carbon cloth electrodes into VRFB is an area of interest for their enhanced electrochemical performance, however, issues with performance degradation throughout the duration of the experiment persist. This study investigates the performance evolution of carbon cloth electrodes during VRFB cycling to build a hypothesis on possible reasons for the declining performance. Electrochemical impedance spectroscopy and polarization curve measurements are used in conjunction to monitor the electrode degradation and shed light on the effectiveness of carbon cloth electrodes during extended cycling experiments. A detailed investigation into the structure of the carbon cloth electrodes before and after cycling, via several material characterization tests, provides insight needed to determine an explanation for the increasing resistance. The structural integrity and surface morphology of the carbon cloth electrodes are evaluated to compare the electrode before and after cycling, displaying any changes to the electrode due to cycling. Durability of hydrophilicity during RFB cycling is found to be a key feature for future carbon cloth electrode design efforts.

25 ENERGY STORAGE↗

System and method for implementing a zero-sequence current filter for a three-phase power system

In a three-phase, four-wire electrical distribution system, a zig-zag transformer and at least one Cascade Multilevel Modular Inverter (CMMI) is coupled between the distribution system and the neutral. A controller modulates the states of the H-bridges in the CMMI to build an AC waveform. The voltage is chosen by the controller in order to control an equivalent impedance that draws an appropriate neutral current through the transformer. This neutral current is generally chosen to cancel the neutral current sensed in the line. The chosen neutral current may be based on a remotely sensed imbalance, rather than on a local value, determined by the power utility as a critical load point in the system. The desired injection current is then translated by the controller into a desired zero-sequence reactive impedance, based on measurement of the local terminal voltage, allowing the controller to regulate the current without generating or consuming real power.

Benavides, Nicholas↗

Engineering structural homogeneity and magnetotransport in strained Nd 2 Ir 2 O 7 films

The 5d pyrochlore iridate family (R 2 Ir 2 O 7 , where R is a rare earth ion) has garnered significant attention due to its topological properties, such as Weyl semimetallic phases and axion insulator. However, the investigation of these properties has been impeded by severe iridium loss during growth, which results in the formation of defects and impurities. Herein, we demonstrate a method for controlling impurities and defects in strained Nd 2 Ir 2 O 7 (NIO-227) films by compensating for iridium loss during growth. By increasing the amount of IrO 2 target ablated, we enhance the morphological quality and electrical transport properties of the fabricated films. Furthermore, our results show that the anomalous Hall effects of the films have a strong dependency on the amount of IrO 2 target ablated, which is attributed to the structural inhomogeneity in the NIO-227 films. Our work provides a way to control defects and impurities and would promote the investigation of topological phases in the family R 2 Ir 2 O 7 .

36 MATERIALS SCIENCE↗

On the Low Risk of SSR in Type III Wind Turbines Operating in Grid-Forming Control: Preprint

We have shown in a previous work that the risk of sub-synchronous resonance (SSR) between a wind power plant with Type III wind turbines and series-compensated transmission lines is low when the wind turbines in the plant are operated in grid-forming mode, instead of the standard grid-following mode. The fundamental mechanism behind the improved damping characteristics is explained in this paper by modeling the positive and negative sequence impedances of Type III wind turbines for GFM operation mode. It is discovered that the GFM control naturally acts against the negative resistance of Type III wind turbines that results from an interaction between the proportional gain of the rotor-side converter current controller and negative slip. The developed sequence impedance models and improved damping behavior are verified using PSCAD simulations of a 2.5-MW Type III GFM wind turbine. The modeling predictions are also supported by experimentally measuring the sequence impedance response of a 2.5-MW Type III wind turbine during operation in GFL and GFM modes.

grid-following turbine↗

Experimental progress and future plans on spherical tokamak, QUEST

QUEST (Q-shu university experiment with steady state spherical tokamak) aims at effective plasma current start-up and stable maintenance of plasma discharge. To solve the inherent problems in a spherical tokamak (ST) arising from insufficient space for placing the inductive center solenoid, electron cyclotron current drive (ECCD) and transient coaxial helicity injection (T-CHI) are implemented as a non-inductive plasma start-up method in QUEST. Efficient ECCD assisted by energetic electrons could be achieved. By combining control of the wave injection angle and application of a negative toroidal electric field, the bulk electron temperature could be raised up to 1 keV due to selective wave power absorption in the bulk electrons. The plasma current of over 50 kA contained within the closed flux surface could be obtained with a floating single biased electrode placed on lower divertor plates for T-CHI. Long-pulse operations on QUEST are impeded frequently due to wall saturation and subsequent density runaway caused by fuel particle imbalance. Since 2014, a unique tool called the ‘hot wall’ has been implemented to overcome the imbalance. The hot wall has a capability to regulate its surface temperature using a heater and two water cooling channels. With the help of the hot wall, 6 h discharges were obtained in 2020. Cooling down of the surface of the hot wall was significantly effective in recovering the wall pumping and was useful to extend the pulse duration. Augmentation of the toroidal magnetic field, B T up to 0.5 T from 0.25 T and a continuous wave (CW) gyrotron of 28 GHz are planned for QUEST in the near future. As raising B T provides a fundamental resonance of electron cyclotron waves (ECWs) with 28 GHz, more effective plasma current start-up and heating will be performed. Long-pulse operations with higher plasma parameters are expected.

QUEST↗

Design Challenges in High-Current Pulsed Striplines

The Long Baseline Neutrino Facility (LBNF) will produce the worlds most intense neutrino beam. Three series connected magnetic horns will require 5 kV, 300 kA, 800 $\mu$s pulses at a rate of 1.4 Hz to focus the beam. Connecting a single power supply to these focusing horns will require a low impedance connection measuring over 60 m in length. To meet the challenging requirements of connecting the horns to the power supply, this connection is engineered as a nine-conductor, high-current pulsed stripline. It must pass through a harsh radiation environment, be passively cooled, and have an operational lifetime of at least 30 years. This paper discusses mechanical and electrical considerations such as high-voltage holdoff, clamped joint performance, and Lorentz force mitigations in order to meet the specified requirements. The results of tests and experiments on several prototypes of key design features will be presented and discussed.

43 PARTICLE ACCELERATORS↗

In-situ monitoring for liquid metal jetting using a millimeter-wave impedance diagnostic

Abstract This article presents a millimeter-wave diagnostic for the in-situ monitoring of liquid metal jetting additive manufacturing systems. The diagnostic leverages a T-junction waveguide device to monitor impedance changes due to jetted metal droplets in real time. An analytical formulation for the time-domain T-junction operation is presented and supported with a quasi-static full-wave electromagnetic simulation model. The approach is evaluated experimentally with metallic spheres of known diameters ranging from 0.79 to 3.18 mm. It is then demonstrated in a custom drop-on-demand liquid metal jetting system where effective droplet diameters ranging from 0.8 to 1.6 mm are detected. Experimental results demonstrate that this approach can provide information about droplet size, timing, and motion by monitoring a single parameter, the reflection coefficient amplitude at the input port. These results show the promise of the impedance diagnostic as a reliable in-situ characterization method for metal droplets in an advanced manufacturing system.

42 ENGINEERING↗

Evaluating the Case for Reduced Precious Metal Catalysts in Proton Exchange Membrane Electrolyzers

Proton exchange membrane (PEM) water electrolyzers are a key technology in decarbonizing hydrogen production. Though the market for PEM electrolyzer systems is growing, there are concerns that the cost and availability of precious metal catalysts utilized in today’s commercial systems can limit deployment. Herein, we show that while the availability of Ir should not impede deployment in the near term, the inelasticity of the Ir commodity price is cause for immediate concern. Here we emphasize that diversifying catalyst materials, even with other precious metals, can reduce system costs and mitigate supply chain risk. Furthermore, we analyze the trade-offs between catalyst capital cost and catalyst activity for a range of operating conditions (i.e., capacity factor, electricity price). The framework presented herein is a first step toward establishing performance targets (i.e., activity, stability, material cost) for reduced precious metal and non-precious metal catalysts as a function of PEM electrolyzer operating conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Local probe of bulk and edge states in a fractional Chern insulator

The fractional quantum Hall effect is a key example of topological quantum many-body phenomena, arising from the interplay between strong electron correlation, topological order and time-reversal symmetry breaking. Recently, a lattice analogue of the fractional quantum Hall effect at zero magnetic field has been observed, confirming the existence of a zero-field fractional Chern insulator (FCI). Despite this, the bulk–edge correspondence—a hallmark of a FCI featuring an insulating bulk with conductive edges—has not been directly observed. In fact, this correspondence has not been visualized in any system for fractional states owing to experimental challenges. Here we report the imaging of FCI edge states in twisted MoTe 2 (t-MoTe 2 ) using microwave impedance microscopy. By tuning the carrier density, we observe the system evolving between metallic and FCI states, the latter of which exhibits insulating bulk and conductive edges, as expected from the bulk–boundary correspondence. Further analysis suggests the composite nature of the FCI edge states. We also observe the evolution of edge states across the topological phase transition as a function of interlayer electric field and reveal exciting prospects of neighbouring domains with different fractional orders. Furthermore, these findings pave the way for research into topologically protected one-dimensional interfaces between various anyonic states at zero magnetic field, such as gapped one-dimensional symmetry-protected phases with non-zero topological entanglement entropy, Halperin–Laughlin interfaces and the creation of non-abelian anyons.

Imaging techniques↗

Investigation of powertrain system decarbonization using electrically assisted turbocharging and hybridization in off-road vehicles

In recent years, the causes, effects, and existential threat of a global anthropogenic climate shift have drawn significant attention and stimulated mitigation efforts from all genres of scientific, political, and industrial bodies. The greenhouse effect and the detrimental environmental impact of excess greenhouse gas (GHG) emissions, like carbon dioxide, is well studied and targeted as the primary culprit for aversive action. However, some fields exist where reducing GHG emissions is met by considerable challenges. One such field is the production and operations of off-road vehicles. Applications of these vehicles are highly diverse and are often characterized by rugged, especially transient, and power intensive duty cycles that make one-fits-all vehicle configuration solutions impractical. This research surveys existing literature to identify the modern technologies packages and challenges that face development and configuration of powertrain systems which currently navigate the regulated emissions and unique duty cycle requirements of this market space. A novel powertrain concept is proposed and evaluated with respect to the pinnacle objectives of load performance improvement, criteria pollutant reduction, and reducing the life cycle GHG intensity of its operation. A sure-fire path to vehicular GHG reduction is through improving the fuel efficiency of internal combustion engines (ICEs), an entrenched component of the off-road vehicle sector. Unfortunately, this is more easily said than done. An approach that has proven successful in this endeavor is engine downsizing and turbocharging, where a larger engine is replaced with a smaller one with added air system boosting via turbocharger to reduce frictional and pumping losses while also enabling access to additional fuel energy. However, practical realization of these potential benefits is often impeded by the transient response capability of the smaller engine across the operating space. For this reason, downsized ICE powertrains have turned to electrified forced induction systems (EFISs) for a decoupling of exhaust energy and engine speed from boost capability. Platformed on 48V hybrid technology, these systems introduce the need for more sophisticated controls around the engine gas-exchange process for the management of boost performance and exhaust gas emissions. On this account, simulation studies utilizing a GT-POWER model of a turbocharged 4.5 L engine outfit with an EFIS using an electrically driven compressor (eBooster®) are conducted to provide insight into the performance of this air handling architecture on an off-road engine. The results show that improvement in transient torque response time in sync with reduction in engine-out soot and NOx emissions are possible with an engine recalibration that leverages the transient air-fuel ratio authority of the eBooster®. Benefits are further demonstrated when duty cycle simulations of the 48V mild-hybrid engine concept are exercised, showing an acute decrease in cumulative fuel usage and soot production. Powertrain hybridization is another technological pathway achieving pronounced GHG reduction successes in modern on-road vehicle applications through integration of Li-ion battery technology. In the off-road vehicle segment, a review of available literature concludes that hybridized architectures are present but generally lack the depth of technologies that have both high specific energy and power capabilities, and thus are limited in their inclusion of Li-ion batteries for ICE assistance and enhanced energy storage capability. Therefore, building on the mild-hybrid engine results, the downsized and eBoosted engine concept was integrated into a larger high-voltage battery-hybrid series-electric powertrain system. Hybrid powertrain parameter sensitivity studies were carried out in a numerical charge-sustaining framework, providing novel insights into power flows between the battery and the engine and how their respective capabilities and operation contribute to GHG and criteria pollutant emissions of diverse duty cycles. Application of supervisory power management introduced robustness into the power sourcing and battery SOC control process and showed that optimum specification of battery properties can yield synergies between GHG emissions and battery energy capacity. Furthermore, examination of recent literature on Li-ion batteries has shown that pack manufacturing is a highly energy intensive process, thereby producing considerable quantities of GHGs that scale with energy storage capacity. Also scaling with a battery’s energy storage capacity is its investment cost. In consideration of these factors, an inclusive technoeconomic and GHG life cycle analysis is conducted. This analysis systematically compares the carbon footprint and total cost of ownership associated with the proposed hybrid powertrain concept to reference and alternative powertrain configurations, facilitating a thorough evaluation of the decarbonization effectiveness and economic viability.

99 GENERAL AND MISCELLANEOUS↗

A Cost-Effective Wave Energy Harvesting System with Maximum Power Point Tracking Capability

In this paper, we propose a low-cost bidirectional four-switch inverter that transfers three-phase energy between a permanent magnet synchronous generator (PMSG) driven by a wave energy collector and the power grid or a local ac load. To achieve high control performance, the machine-side inverter uses a high-gain observer for rotor position estimation and a Lyapunov-based approach for torque control. For the gridside inverter control, we estimate the filter capacitor voltage with a model reference adaptive system and control the dc-link voltage with a Lyapunov-based energy function. We also track the maximum power point from the sea waves with an integral control law that actively matches the generator impedance with that of the wave collection device. The proposed system supports both grid-following/forming modes. We validate our control design with simulation results on a 3-kW hardware setup.