Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRONIC RECORDING INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Visible-to-THz near-field nanoscopy

Optical microscopy has a key role in research, development and quality control across a wide range of scientific, technological and medical fields. However, diffraction limits the spatial resolution of conventional optical instruments to about half the illumination wavelength. A technique that surpasses the diffraction limit in the wide spectral range between visible and terahertz frequencies is scattering-type scanning near-field optical microscopy (s-SNOM). The basis of s-SNOM is an atomic force microscope in which the tip is illuminated with light from the visible to the terahertz spectral range. By recording the elastically tip-scattered light while scanning the sample below the tip, s-SNOM yields near-field optical images with a remarkable resolution of 10 nm, simultaneously with the standard atomic force microscopic topography image. This resolution is independent of the illumination wavelength, rendering s-SNOM a versatile nanoimaging and nanospectroscopy technique for fundamental and applied studies of materials, structures and phenomena. This Review presents an overview of the fundamental principles governing the measurement and interpretation of near-field contrasts and discusses key applications of s-SNOM. We also showcase emerging developments that enable s-SNOM to operate under various environmental conditions, including cryogenic temperatures, electric and magnetic fields, electrical currents, strain and liquid environments. Furthermore, all these recent developments broaden the applicability of s-SNOMs for exploring fundamental solid-state and quantum phenomena, biological matter, catalytic reactions and more.

Hillenbrand, Rainer [CIC nanoGUNE BRTA and Departm↗

Scaling and merging time-resolved pink-beam diffraction with variational inference

Time-resolved x-ray crystallography (TR-X) at synchrotrons and free electron lasers is a promising technique for recording dynamics of molecules at atomic resolution. While experimental methods for TR-X have proliferated and matured, data analysis is often difficult. Extracting small, time-dependent changes in signal is frequently a bottleneck for practitioners. Recent work demonstrated this challenge can be addressed when merging redundant observations by a statistical technique known as variational inference (VI). However, the variational approach to time-resolved data analysis requires identification of successful hyperparameters in order to optimally extract signal. In this case study, we present a successful application of VI to time-resolved changes in an enzyme, DJ-1, upon mixing with a substrate molecule, methylglyoxal. We present a strategy to extract high signal-to-noise changes in electron density from these data. Furthermore, we conduct an ablation study, in which we systematically remove one hyperparameter at a time to demonstrate the impact of each hyperparameter choice on the success of our model. We expect this case study will serve as a practical example for how others may deploy VI in order to analyze their time-resolved diffraction data.

47 OTHER INSTRUMENTATION↗

Characterization of PuO 2 With Visible and UV Raman Spectroscopy: Discrimination Between the Bulk, Surface, and an Intermediate Disordered Layer

Raman spectroscopy is an ideal tool in the characterization of materials including PuO 2 . The wavelength-dependent absorptivity of the material defines the light penetration depth and the relative Raman scattering contribution from the bulk and the surface. Here, the surface contribution to the total Raman scattering was investigated for PuO 2 calcined at various temperatures and recorded with laser wavelengths of 355, 325, and 244 nm. These experiments provided the first glimpse of the wavelength-dependent disappearance and emergence of new phonons and electronic bands from the PuO 2 surface layers. The first indication of the wavelength transition in the Raman spectra was the loss of the 2LO2 (overtone, ~1155 cm -1 ) band and the weakening intensity of the Г 1 → Γ 5 electronic band (~2135 cm -1 ) with the 355-nm excitation laser. The Γ 5 electronic band was barely visible with the 244-nm excitation. The electronic band located at ~1050 cm -1 , corresponding to the Г 1 → Γ 4 electronic transition was observed to dramatically increase in intensity while the Г 1 → Γ 3 electronic band (2640 cm -1 ) sharpened as the UV wavelength was increased in energy from the near- to deep-UV (355–325–244 nm). The FWHM of the T 2g band was found to vary with calcination temperature (450°C and 900°C) with the 325-nm laser and the 244-nm laser. The T 2g band attributes, the strong emergence of the Г 1 → Γ 4 electronic band, and the disappearance of the 2LO2 overtone acquired with the 244-nm excitation for the different calcination temperatures suggest a shallow penetration depth.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Boron Nitride Solid-State Neutron Detectors

The goal of this project is to build upon the work performed under the Texas Tech IDEAS project (DE-AR0000964 monitored by Dr. Isik Kizilyalli) to bring the developed B-10 enriched hexagonal boron nitride (h- 10 BN or 10 BN or BN) semiconductor neutron detector technology to the next level of maturity. In comparison to He-3 ( 3 He) gas detectors, BN neutron detectors possess all the intrinsic advantages of semiconductor devices: light weight, compact size, fast response speed, high spatial resolution, high temperature and low voltage operation capability, ease of mass production via existing semiconductor infrastructures, low cost of operation and maintenance, flexible form factors, and durability. The project will develop a prototype h- 10 BN neutron detector as a potential replacement for the 3 He gas neutron detectors (LND 25185 or equivalent) used in various neutron survey meters currently produced and commercialized by Ludlum Measurements, Inc. (LMI). To increase the overall detection efficiency, it is essential to maximize the collection efficiency of charge carriers (electrons and holes) generated by the nuclear reaction, which demands a further push to achieve 10 BN epilayers with improved material quality. The material growth processes will be guided by characterization of structural, optical, and electrical properties of h-BN. Selective devices will be calibrated at LMI. During ARPA-E supporting period, the key material parameters of h-BN produced by metal organic chemical vapor deposition (MOCVD), including the layer thickness, mobility-lifetime product, surface recombination field and detector size for maintaining a high charge collection efficiency all have been improved by several orders of magnitude. These improvements have enabled the realization of high-performance h 10BN semiconductor thermal neutron detectors. Presently, h- 10 BN thermal neutron detectors developed under ARPA-E’s support hold the record high detection efficiency among all solid-state detectors at 59%. With further development in manufacturing, there is no question that h-BN detectors will replace the traditional He-3 gas detectors in certain application areas by offering obvious advantages of semiconductor technologies over gas detectors and opportunities for users to dedicate the scarce and expensive supply of He-3 gas to other application areas where substitutes of He-3 gas are not possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

4D-STEM of Beam-Sensitive Materials

We report that a scanning electron nanobeam diffraction, or 4D-STEM (four-dimensional scanning transmission electron microscopy), is a flexible and powerful approach to elucidate structure from "soft" materials that are challenging to image in the transmission electron microscope because their structure is easily damaged by the electron beam. In a 4D-STEM experiment, a converged electron beam is scanned across the sample, and a pixelated camera records a diffraction pattern at each scan position. This four-dimensional data set can be mined for various analyses, producing maps of local crystal orientation, structural distortions, crystallinity, or different structural classes. Holding the sample at cryogenic temperatures minimizes diffusion of radicals and the resulting damage and disorder caused by the electron beam. The total fluence of incident electrons can easily be controlled during 4D-STEM experiments by careful use of the beam blanker, steering of the localized electron dose, and by minimizing the fluence in the convergent beam thus minimizing beam damage. This technique can be applied to both organic and inorganic materials that are known to be beam-sensitive; they can be highly crystalline, semicrystalline, mixed phase, or amorphous. One common example is the case for many organic materials that have a π-π stacking of polymer chains or rings on the order of 3.4-4.2 Å separation. If these chains or rings are aligned in some regions, they will produce distinct diffraction spots (as would other crystalline spacings in this range), though they may be weak or diffuse for disordered or weakly scattering materials. We can reconstruct the orientation of the π-π stacking, the degree of π-π stacking in the sample, and the domain size of the aligned regions. This Account summarizes illumination conditions and experimental parameters for 4D-STEM experiments with the goal of producing images of structural features for materials that are beam-sensitive. We will discuss experimental parameters including sample cooling, probe size and shape, fluence, and cameras. 4D-STEM has been applied to a variety of materials, not only as an advanced technique for model systems, but as a technique for the beginning microscopist to answer materials science questions. It is noteworthy that the experimental data acquisition does not require an aberration-corrected TEM but can be produced on a variety of instruments with the right attention to experimental parameters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GRAPH — an readout ASIC for large MCP based detectors

We present a programmable 16 channel, mixed signal, low power readout ASIC, having the project historically named Gigasample Recorder of Analog waveforms from a PHotodetector (GRAPH). It is designed to read large aperture single photon imaging detectors using micro channel plates for charge multiplication, and measuring the detector's response on crossed strips anodes to extrapolate the incoming photon position. Each channel consists of a fast, low power and low noise charge sensitive amplifier, which provides a myriad of coarse and fine programmable options for gain and shaping settings. Further, the amplified signal is recorded using, to our knowledge novel, the Hybrid Universal sampLing Architecture (HULA) ADC. A kind of mixed signal double buffer memory, that enables concurrent waveform recording, and selected event digitized data extraction. The sampling frequency is freely adjustable between few kHz up to 125 MHz, while the chip's internal digital memory holds a history 2048 samples for each channel, with a digital headroom of 12 bits. An optimized region of interest sample-read algorithm allows to extract the information just around the event pulse peak, while selecting the next event, thus substantially reducing the operational dead time. The chip is designed in 130 nm TSMC CMOS technology, and its power consumption is around 47 mW per channel.

47 OTHER INSTRUMENTATION↗

Extreme Enhancement-Mode Operation Accumulation Channel Hydrogen-Terminated Diamond FETs with V th < -6 V and High on-Current

In this work, a new Field Effect Transistor device concept based on hydrogen-terminated diamond (H-diamond) is demonstrated that operates in an Accumulation Channel rather than a Transfer Doping regime. The FET devices demonstrate both extreme enhancement-mode operation and high on-current with improved channel charge mobility compared to Transfer-Doped equivalents. Electron-beam evaporated Al 2 O 3 is used on H-diamond to suppress the Transfer Doping mechanism and produce an extremely high ungated channel resistance. A high-quality H-diamond surface with an unpinned Fermi level is crucially achieved, allowing for the formation of a high-density hole accumulation layer by gating the entire device channel which is encapsulated in dual-stacks of Al 2 O 3 . Completed devices with gate/channel length of 1 µm demonstrate record threshold voltage < -6 V with on-current > 80 mA mm -1 . Carrier density and mobility figures extracted by CV analysis indicate a high 2D charge density of ≈ 2 × 10 12 cm -2 and increased hole mobility of 110 cm 2 V -1 s -1 in comparison with more traditional Transfer-Doped H-diamond FETs. These results demonstrate the most negative threshold voltage yet reported for H-diamond FETs and highlight a powerful new strategy to greatly improve carrier mobility and enable enhanced high power and high frequency diamond transistor performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Partial Charge Collection Induced by Neutron Damage in High-Purity Germanium Detectors

This paper investigates the correlation of damage induced by neutron interactions and degradation in the spectra of HPGe detectors. As neutrons kinetically interact with germanium crystals, they create interstitial and vacancy defects within the lattice. These defects then interfere with the charge migration of electron-hole pairs and reduce resolution in the observed energy spectrum. The partial charge collection produces observable spectral changes by increasing the peak width and reducing resolution (full width half maximum). A detailed characterization using various check sources was performed before and after iterations of neutron exposure in order to observe the effects of the neutron damage. An additional set of measurements was performed along with characterizations to show the detector’s response at discrete locations on the HPGe crystal. This was done to observe how the spectrum changes when the gamma rays are isolated to regions of various thicknesses of germanium. In order to impart damage, the detector was placed inside a californium shuffler with the face of the detector against the guide tube for the 252 Cf source. For irradiation of the HPGe, the source was then positioned in front of the face of the detector using the stepper motor of the shuffler. The neutron exposure time intervals were recorded and increased based on the initial damage observed. An MCNP simulation was performed to estimate the amount of interactions that occurred in the germanium crystal to ensure enough damage had occurred. Studying the effects that neutron damage imparts on a bullet-type HPGe detector can help provide necessary data to estimate total neutron exposure limits, reduce the likelihood of decisions made on suspect data, and aid in diagnostics of a damaged detector.

36 MATERIALS SCIENCE↗

3D diffractive imaging of nanoparticle ensembles using an x-ray laser

Single particle imaging at x-ray free electron lasers (XFELs) has the potential to determine the structure and dynamics of single biomolecules at room temperature. Two major hurdles have prevented this potential from being reached, namely, the collection of sufficient high-quality diffraction patterns and robust computational purification to overcome structural heterogeneity. We report the breaking of both of these barriers using gold nanoparticle test samples, recording around 10 million diffraction patterns at the European XFEL and structurally and orientationally sorting the patterns to obtain better than 3-nm-resolution 3D reconstructions for each of four samples. With these new developments, integrating advancements in x-ray sources, fast-framing detectors, efficient sample delivery, and data analysis algorithms, we illuminate the path towards sub-nanometer biomolecular imaging. The methods developed here can also be extended to characterize ensembles that are inherently diverse to obtain their full structural landscape.

47 OTHER INSTRUMENTATION↗

Solution phase high repetition rate laser pump x-ray probe picosecond hard x-ray spectroscopy at the Stanford Synchrotron Radiation Lightsource

We present a dedicated end-station for solution phase high repetition rate (MHz) picosecond hard x-ray spectroscopy at beamline 15-2 of the Stanford Synchrotron Radiation Lightsource. A high-power ultrafast ytterbium-doped fiber laser is used to photoexcite the samples at a repetition rate of 640 kHz, while the data acquisition operates at the 1.28 MHz repetition rate of the storage ring recording data in an alternating on-off mode. The time-resolved x-ray measurements are enabled via gating the x-ray detectors with the 20 mA/70 ps camshaft bunch of SPEAR3, a mode available during the routine operations of the Stanford Synchrotron Radiation Lightsource. As a benchmark study, aiming to demonstrate the advantageous capabilities of this end-station, we have conducted picosecond Fe K-edge x-ray absorption spectroscopy on aqueous [FeII(phen)3]2+, a prototypical spin crossover complex that undergoes light-induced excited spin state trapping forming an electronic excited state with a 0.6–0.7 ns lifetime. In addition, we report transient Fe Kβ main line and valence-to-core x-ray emission spectra, showing a unique detection sensitivity and an excellent agreement with model spectra and density functional theory calculations, respectively. Notably, the achieved signal-to-noise ratio, the overall performance, and the routine availability of the developed end-station have enabled a systematic time-resolved science program using the monochromatic beam at the Stanford Synchrotron Radiation Lightsource.

47 OTHER INSTRUMENTATION↗

The Resource Prospector Neutron Spectrometer System: RP's Bloodhound

The primary goal of the Resource Prospector Neutron Spectrometer System (NSS) is to locate and characterize hydrogen-bearing volatile deposits, especially subsurface ice, that may exist at the lunar poles. A key objective is to detect water-equivalent hydrogen concentrations of 0.5 wt% or greater while on a moving rover. A second objective is to determine approximate burial depth of enhanced hydrogen-bearing materials up to 1 meter below otherwise dry regolith. The instrument will be carried aboard a landed mobility system at the lunar poles. The instrument operates by measuring the changes in the leakage flux of low energy neutrons out of the regolith. These neutrons are produced by galactic cosmic rays, which are so energetic that they shatter the nuclei in surface materials. The neutrons interact with other nuclei and lose energy, becoming thermalized in the process. Hydrogen is most efficient at thermalizing neutrons owing to protons' similar mass - statistically, neutrons lose half their energy per collision with protons. With hydrogen in the soil, leakage fluxes of neutrons in the 0.5 eV to 500 keV energy range are reduced. A concentration of only1-2 wt% water-equivalent hydrogen results in a decrease in epithermal leakage flux of a factor of two. The leakage flux of thermal neutrons, from 0 to 0.5 eV in energy, can either increase or decrease depending on the hydrogen abundance and stratigraphy. As with the highly successful Lunar Prospector Neutron Spectrometer, the RP NSS detects both thermal and epithermal neutrons by using two helium-3 gas proportional counters, one covered by cadmium and the other uncovered. The former detects only epithermal neutrons with energies above approximately 0.5 eV, the latter detects both thermal (less than 0.5 eV) and epithermal energies (greater than 0.5 eV). When a neutron enters the detector tube and interacts with a helium-3 nucleus, the resulting reaction produces an energetic proton and triton that ionize the gas. The resulting electrons are accelerated toward a high-voltage anode and cascade, amplifying the net charge, which is collected at the anode. The number of electrons produced is proportional to the energy that the triton and proton deposit in the gas. A charge sensitive pre-amplifier converts the total charge to a step voltage output. A shaper amplifier then shapes this step into a uni-polar waveform with peaking time appropriate for the detection depending on the event rate. The integrated shaped waveform, representing the deposited triton/proton energy, is then measured. A histogram, or pulse height analysis, is performed to record the main capture peak and wall effect pulses. A threshold for detection is also required to limit the low amplitude counting rate such as noise floor. The system electronics consists of 2 modules - the Sensor Module (SM) front-end and the Data Processing Module (DPM) back-end circuits. SM is designed as a light-weight and low power front-end housing the two helium-3 proportional counter detectors, preamp and HVPS. It is mounted external to the rover body to detect the thermalized neutron flux with a minimum of host background. The DPM is located inside the rover; it digitizes the SM signals, performs pulse height analysis and accumulates the count rate for each spectral channel. The DPM controls high voltage and thresholding, and sends the science data to the host craft via an RS422 serial asynchronous protocol. The payload host provides all thermal management and control for the SM and DPM.

hydrogen-bearing volatile deposits↗

SRF cavity instability detection with machine learning at CEBAF

During the operation of the Continuous Electron Beam Accelerator Facility (CEBAF), one or more unstable superconducting radio-frequency (SRF) cavities often cause beam loss trips while the unstable cavities themselves do not necessarily trip off. The present RF controls for the legacy cavities report at only 1 Hz, which is too slow to detectfast transient instabilities during these trip events. These challenges make the identification of an unstable cavity out of the hundreds installed at CEBAF a difficult and time-consuming task. To tackle these issues, a fast data acquisition system (DAQ) for the legacy SRF cavities has been developed, which records the sample at 5 kHz. An unsupervised learning framework has been developed to identify anomalous SRF cavity behavior. We will discuss the present status of the DAQ system and our framework, along with recent successes in detecting anomalous cavity behavior. Overall, our method offers a practical solution for identifying unstable SRF cavities, contributing to increased beam availability and machine reliability.

Accelerator Physics↗

SRF cavity instability detection with machine learning at CEBAF

During the operation of the Continuous Electron Beam Accelerator Facility (CEBAF), one or more unstable superconducting radio-frequency (SRF) cavities often cause beam loss trips while the unstable cavities themselves do not necessarily trip off. The present RF controls for the legacy cavities report at only 1 Hz, which is too slow to detectfast transient instabilities during these trip events. These challenges make the identification of an unstable cavity out of the hundreds installed at CEBAF a difficult and time-consuming task. To tackle these issues, a fast data acquisition system (DAQ) for the legacy SRF cavities has been developed, which records the sample at 5 kHz. An unsupervised learning framework has been developed to identify anomalous SRF cavity behavior. We will discuss the present status of the DAQ system and our framework, along with recent successes in detecting anomalous cavity behavior. Overall, our method offers a practical solution for identifying unstable SRF cavities, contributing to increased beam availability and machine reliability.

Accelerator Physics↗

Microbial Pigments and Their Degradation Products as Biosignatures

Carotenoids are a class of vibrant biological pigments that have a characteristic chemical structure centered around a polyene core (Lu et al. 2018). Carotenoids and their derivatives are candidate biosignatures because they can persist in the terrestrial geologic record for up to 1.73 billion years (Vinnichenko et al. 2020), have specific structures that are likely the result of complex pathways, mediate the survival of many microorganisms in Mars and Ocean Worlds analog environments, and are detectable with multiple techniques, including Raman spectroscopy. In this project, we aim to investigate the detectability of carotenoid pigments with different spectroscopic methods to inform future instrument selection. We compare the spectra of five unaltered carotenoids, two model compounds, and carotenoid-forming archaeon with visible and deep UV Raman spectroscopy and UVVis absorption spectrophotometry. We then use one model pigment, beta-carotene, to evaluate the likelihood that unique spectral properties of carotenoids, or their refractory byproducts, would be preserved and detectable on a remote planetary surface by exposing it to simulated conditions for Mars. Sample Acquisition. Pigments betacarotene, lutein, zeaxanthin, astaxanthin, and lycopene were purchased from Sigma Aldrich. Halobacterium salinarum NRC-1 was acquired from Carlina Biological and grown in Halobacterium media. Mineral salts including sodium sulfate, sodium carbonate, and halite were used to form matrices in which the beta-carotene was embedded before exposure. Pigment-mineral mixes were at a 1:10 ratio in water. Analytical Techniques. Deep UV Raman data were collected on a custom laboratory mapping spectrometer called MOBIUS (Mineral and Organic Based Investigations using Ultraviolet Spectroscopy), which is an analog to the SHERLOC instrument on the Mars 2020 Perseverance rover (Bhartia et al. 2021). It features a 248.56 nm NeCu pulsed laser, liquid nitrogen-cooled detector, and tunable optical setup. Visible Raman data were collected using a Horiba Jobin Yvon LabRam HR spectrometer with a frequencydoubled Nd:YAG laser (532 nm) and a HeNe laser (633 nm). A VWR 6300 PC UV/Visible Spectrophotometer was used to collect absorption data for carotenoid solutions, model compounds, and solvents in UVpermissible capped cuvettes. Data were collected from 190-1100 nm at 1 nm increments. All spectral data were analyzed using Igor Pro 9 (Wavemetrics). Irradiation. We used a vacuum chamber equipped with a cryostat and a flood electron gun to simulate Martian surface temperatures, low pressures, and ionizing radiation (10keV, 10μA for 6h at 200K for our initial tests). The samples were prepared by drying the pigment-mineral mix onto polished metal tabs, then mounted on the cryostat for processing. Samples were then analyzed directly on the tabs after exposure. Results: In comparing the visible and deep UV Raman spectra of unaltered pigments, we found that they differed drastically. Carotenoids are often studied with visible Raman and typically have peaks at 1525 cm-1 and 1157 cm-1, due to the stretching of the C=C and C-C bonds in the polyene structure. However, in deep UV, the strongest feature is at ~1630 cm-1 and is broad, possibly indicating that multiple peaks are forming this feature. This stark difference is likely due to different preresonant enhancement effects. The UV-Vis results show that there is an absorption band in the deep UV <300 nm, which supports the hypothesis that the 248.6 nm excitation is interrogating another aspect of carotenoids than visible Raman. Our preliminary exposure tests indicated that pigments – even without minerals present - were largely unaltered in the applied conditions, with only a slight broadening in the primary polyene peaks apparent in the visible Raman data. Figure 1. A) Visible vs. deep UV Raman spectra of unaltered beta carotene. B) Schematic of exposure. Conclusions: Our results to date indicate that deep UV and visible Raman spectroscopy, both techniques with planetary mission heritage from Mars 2020 (Wiens et al. 2021, Bhartia et al. 2021), may be used in a complementary manner to observe carotenoids. In addition, we find that beta-carotene is largely resistant to our current exposure conditions, though there may be some amount of amorphization of the material which could cause the broadening of the peaks at 1525 and 1157 cm-1. As a next step, we aim to increase the dosage and duration of exposure to observe degradation of the parent pigment, possibly add UV as a factor via an Ar mini-arc UV lamp and use GC-MS to characterize possible degradation products.

pigments↗

Design, construction and commissioning of a technological prototype of a highly granular SiPM-on-tile scintillator-steel hadronic calorimeter

The CALICE collaboration is developing highly granular electromagnetic and hadronic calorimeters for detectors at future energy frontier electron-positron colliders. After successful tests of a physics prototype, a technological prototype of the Analog Hadron Calorimeter has been built, based on a design and construction techniques scalable to a collider detector. The prototype consists of a steel absorber structure and active layers of small scintillator tiles that are individually read out by directly coupled SiPMs. Each layer has an active area of 72 × 72 cm^2 and a tile size of 3 × 3 cm^2. With 38 active layers, the prototype has nearly 22,000 readout channels, and its total thickness amounts to 4.4 nuclear interaction lengths. The dedicated readout electronics provide time stamping of each hit with an expected resolution of about 1 ns. The prototype was constructed in 2017 and commissioned in beam tests at DESY. It recorded muons, hadron showers and electron showers at different energies in test beams at CERN in 2018. In this paper, the design of the prototype, its construction and commissioning are described. The methods used to calibrate the detector are detailed, and the performance achieved in terms of uniformity and stability is presented.

47 OTHER INSTRUMENTATION↗

Search for New Physics with the Compact Muon Solenoid Experiment and QIS-enabled Technology

Understanding the fundamental nature of dark matter (DM)---its cosmological origin, constituents, and interactions---is one of the most important questions in fundamental science today. In this thesis, I present two novel and highly complementary approaches to cover the gaps in sensitivity of current DM searches. The searches are enabled by a first-of-its-kind reconstruction technique to search for hidden-sector particles using the Compact Muon Solenoid (CMS) and by new advances in quantum sensing technology to search for axions and hidden-sector DM. In the first part of this thesis, I present a search for long-lived hidden sector particles, predicted by many extensions of the SM, using a novel technique to reconstruct decays of long-lived particles (LLPs) in the CMS muon detector. The innovative LLP reconstruction technique is sensitive to a broad range of LLP decays and to LLP masses below GeV. The search yields competitive sensitivity for proper lifetime 0.1--1000 m with the full Run 2 dataset recorded at the LHC between 2016--2018 at $\sqrt{s} = 13~$TeV. To extend the physics reach of this novel muon detector shower (MDS) signature, I present the model-independence of MDS and the reinterpretation of the search to a large number of LLP models, demonstrating its complementarity with proposed and existing dedicated LLP experiments. Finally, I present a new dedicated MDS trigger that improves the trigger efficiency by at least an order of magnitude and was deployed in 2022, at the start of Run 3 of the LHC operations. In the second part of the thesis, I present for the first time, the use of a novel quantum sensor, the low-noise and single-photon sensitive superconducting nanowire single photon detectors (SNSPDs), to directly detect dark matter. The low detection threshold and ultra-low dark count rate of SNSPDs can close the gap in DM discovery reach due to the current limitations in detector sensitivity. I will present my work on the development and characterization of SNSPDs for two entirely new experiments to directly detect axions via absorption and hidden-sector DM via electron scattering. The search for axions employs a novel broadband reflector technique with the Broadband Reflector Experiment for Axion Detection (BREAD). A unique parabolic mirror is then used to focus axion-converted photons to the SNSPDs, extending the reach to axion masses of 0.04--1 eV. On the other hand, by coupling the SNSPDs with gallium arsenide, a bright cryogenic scintillator well matched to SNSPD detection, a prototype sensing system can be built as a basis of new direct DM detection experiments capable of extending the discovery to DM masses as low as 1 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The GlueX beamline and detector

The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 $μs$. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. Here, we describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron and photon reconstruction and identification with the CMS experiment at the CERN LHC

The performance is presented of the reconstruction and identification algorithms for electrons and photons with the CMS experiment at the LHC. The reported results are based on proton-proton collision data collected at a center-of-mass energy of 13 TeV and recorded in 2016–2018, corresponding to an integrated luminosity of 136 fb^-1. Results obtained from lead-lead collision data collected at √(sNN)=5.02 TeV are also presented. Innovative techniques are used to reconstruct the electron and photon signals in the detector and to optimize the energy resolution. Events with electrons and photons in the final state are used to measure the energy resolution and energy scale uncertainty in the recorded events. The measured energy resolution for electrons produced in Z boson decays in proton-proton collision data ranges from 2 to 5%, depending on electron pseudorapidity and energy loss through bremsstrahlung in the detector material. The energy scale in the same range of energies is measured with an uncertainty smaller than 0.1 (0.3)% in the barrel (endcap) region in proton-proton collisions and better than 1 (3)% in the barrel (endcap) region in heavy ion collisions. The timing resolution for electrons from Z boson decays with the full 2016–2018 proton-proton collision data set is measured to be 200 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗