Thermal Performance Evaluation of Walls with Gas Filled Panel Insulation

Gas filled insulation panels (GFP) are very light weight and compact (when uninflated) advanced insulation products. GFPs consist of multiple layers of thin, low emittance (low-e) metalized aluminum. When expanded, the internal, low-e aluminum layers form a honeycomb structure. These baffled polymer chambers are enveloped by a sealed barrier and filled with either air or a low-conductivity gas. The sealed exterior aluminum foil barrier films provide thermal resistance, flammability protection, and properties to contain air or a low conductivity inert gas. This product was initially developed with a grant from the U.S. Department of Energy. The unexpanded product is nearly flat for easy storage and transport. Therefore, transportation volume and weight of the GFP to fill unit volume of wall cavity is much smaller compared to that of other conventional insulation products. This feature makes this product appealing to use at Army Contingency Basing, when transportation cost is significant compared to the cost of materials. The objective of this study is to evaluate thermal performance of walls, similar to those used at typical Barracks Hut (B-Hut) hard shelters, when GFPs are used in the wall cavities. Oak Ridge National Laboratory (ORNL) tested performance of the wall in the rotatable guarded hotbox (RGHB) according to the ASTM C 1363 standard test method.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Nest Home

The purpose of the project was to build a competitive solar-powered house for the U.S. Department of Energy Solar Decathlon 2015 held in Irvine, California. The house, named the Nest Home, was an innovative design that works with the environment to meet the needs of the occupants, identified as a growing family. Reused materials were instrumental in the design. Three refurbished shipping containers composed the primary structure of the house, creating an open floor plan that defies common architecture for container homes. The exterior siding was made of deconstructed shipping pallets collected locally. Other recycled products included carpet composed of discarded fishing nets, denim batting made of recycled blue jeans that outperform traditional fiberglass insulation in sound proofing and thermal resistance, and kitchen cabinets that were purchased used and refinished. Collectively these elements formed a well-balanced blend of modern design, comfort, and sustainability. The house was Missouri University of Science and Technology’s sixth entry in the DOE Solar Decathlon. Missouri S&T has been invited to compete in six of the seven decathlons held, more than any other university worldwide. The house was brought back to Rolla after the Decathlon in California where it has been placed in its permanent location on the S&T campus.

14 SOLAR ENERGY↗

A theoretical study of non-adiabatic surface effects for a model in the NTF cryogenic wind tunnel

A theoretical analysis was made of the severity and effect of nonadiabatic surface conditions for a model in the NTF cryogenic wind tunnel. The nonadiabatic condition arises from heaters that are used to maintain a constant thermal environment for instrumentation internal to the model. The analysis was made for several axi-symmetric representations of a fuselage cavity, using a finite element heat conduction code. Potential flow and boundary layer codes were used to calculate the convection condition for the exterior surface of the model. The results of the steady state analysis show that it is possible to maintain the surface temperature very near the adiabatic value, with the judicious use of insulating material. Even for the most severe nonadiabatic condition studied, the effects on skin friction drag and displacement thickness were only marginally significant. The thermal analysis also provided an estimate of the power required to maintain a specified cavity temperature.

Macha, J. M.↗

Thermal Performance of Uninsulated and Partially Filled Wall Cavities

Wall cavities are widely present in the construction of low rise homes since wood framing is the most common type of construction for residential buildings in the United States. The primary function of such wall construction is to provide a stable frame to which interior and exterior wall coverings can be attached and by which a roof can be supported. The existence of wall cavities increases the thermal resistance of the enclosure, particularly when they are filled with insulating material. Several design guides provide data for prediction of the thermal resistance of uninsulated wall cavities of varying internal geometries. However, U-value coefficients provided in these guides do not account for partially insulated cavities or for variations in aspect ratio. Whole building energy simulation tools, like DOE2 or Energy Plus, use simplified, 1-D characterization of building envelopes. For the most part, this characterization assumes a fixed thermal resistance over the range of temperatures experienced by the enclosure. In reality, the thermal resistance is dominated by convection and radiation and is a function of several parameters, including the temperatures and emissivities of the cavity surfaces and the aspect ratio of the cavity. This study describes detailed CFD modeling to evaluate the thermal performance of uninsulated or partially filled wall cavities accounting for conduction through framing, convection, and radiation. The resulting correlations can serve as input for DOE2 and Energy Plus modeling of older homes, where the walls are either uninsulated or partially insulated due to the settling of the insulating material. Parameters of the study are the ambient temperature outdoors, emissivity of the cavity surfaces, cavity aspect ratio, and height of the insulation level. The outcomes of this study provide: An understanding of the thermal performance of uninsulated or partially insulated wall cavities, which is an essential aspect of energy conservation in residential buildings. Accurate input for whole building simulations models like DOE2 and Energy Plus in various climate zones. Recommendations on retrofit measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A concept of integrated environmental approach for building upgrades and new construction: Part 1—setting the stage

This article highlights the need for an active role for building physics in the development of near-zero energy buildings while analyzing an example of an integrated system for the upgrade of existing buildings. The science called either Building Physics in Europe or Building Science in North America has so far a passive role in explaining observed failures in construction practice. In its new role, it would be integrating modeling and testing to provide predictive capability, so much needed in the development of near-zero energy buildings. The authors attempt to create a compact package, applicable to different climates with small modifications of some hygrothermal properties of materials. This universal solution is based on a systems approach that is routine for building physics but in contrast to separately conceived sub-systems that are typical for the design of buildings today. One knows that the building structure, energy efficiency, indoor environmental quality, and moisture management all need to be considered to ensure durability of materials and control cost of near-zero energy buildings. These factors must be addressed through contributions of the whole design team. The same approach must be used for the retrofit of buildings. As this integrated design paradigm resulted from demands of sustainable built environment approach, building physics must drop its passive role and improve two critical domains of analysis: (i) linked, real-time hygrothermal and energy models capable of predicting the performance of existing buildings after renovation and (ii) basic methods of indoor environment and moisture management when the exterior of the building cannot be modified.

Building physics↗

MISSE-Flight Facility Polymers and Composites Experiment 1-4 (PCE 1-4)

Spacecraft in low Earth orbit (LEO) are subjected to harsh environmental conditions, including radiation (cosmic rays, ultraviolet (UV), x-ray and charged particle radiation), micrometeoroids and orbital debris, temperature extremes, thermal cycling, and atomic oxygen (AO). These environmental exposures can result in erosion, embrittlement and optical property degradation of susceptible materials threatening spacecraft performance and durability. To increase our understanding of effects such as AO erosion and radiation induced embrittlement of spacecraft materials, NASA Glenn Research Center has developed a series of experiments that are flown as part of the Materials International Space Station Experiment (MISSE) missions on the exterior of the International Space Station (ISS). These experiments have provided critical space environmental durability data such as AO erosion data of polymers and composites, and radiation induced mechanical property degradation of spacecraft insulation materials, after long term space exposure. In continuing these studies, four Glenn experiments have been flown on ISS’s MISSE-Flight Facility (MISSE-FF). These experiments are the Polymers and Composites Experiment-1 (PCE-1) flown as part of the inaugural MISSE-9 mission, the PCE-2 flown as part of the MISSE-10 mission, the PCE-3 being flown as part of the MISSE-12 mission, and the PCE-4 being flown as part of the MISSE-13 mission. This paper provides an overview of space environmental effects on spacecraft materials and Glenn’s PCE 1-4 MISSE-FF experiments.

Atomic oxygen↗

Initial Results of the MISSE-Flight Facility Polymers and Composites Experiment 1-4 (PCE 1-4)

Spacecraft in low Earth orbit (LEO) are subjected to harsh environmental conditions, including radiation (cosmic rays, ultraviolet (UV), x-ray and charged particle radiation), micrometeoroids and orbital debris, temperature extremes, thermal cycling, and atomic oxygen (AO). These environmental exposures can result in erosion, embrittlement and optical property degradation of susceptible materials threatening spacecraft performance and durability. To increase our understanding of effects such as AO erosion and radiation induced embrittlement of spacecraft materials, NASA Glenn Research Center has developed a series of experiments that are flown as part of the Materials International Space Station Experiment (MISSE) missions on the exterior of the International Space Station (ISS). These experiments have provided critical space environmental durability data such as AO erosion data of polymers and composites, and radiation induced mechanical property degradation of spacecraft insulation materials, after long term space exposure. In continuing these studies, four Glenn experiments with 365 flight samples have been flown on ISS’s external MISSE-Flight Facility (MISSE-FF). These experiments are the Polymers and Composites Experiment-1 (PCE-1) flown as part of the inaugural MISSE-9 mission, the PCE-2 flown as part of the MISSE-10 mission, the PCE-3 flown as part of the MISSE-12 and MISSE-15 missions, and the PCE-4 flown as part of the MISSE-13 mission. The primary objective of the PCE 1-4 experiments is to determine the AO and radiation durability of spacecraft polymers and composites. In addition, each experiment has a wide variety of spacecraft materials and hence they each have numerous additional sample objectives. Each of the PCE 1-4 is designed to examine the consequences of AO interactions including AO erosion yield (Ey) and optical and thermal property characterization. Several polymers were flown in both ram and zenith flight orientations to determine the effect of varying solar to AO ratios on Ey. Common spacecraft materials including Teflon FEP, white Tedlar and Upilex-S were included on multiple MISSE missions so erosion dependence on environment exposure can be determined. The PCE-1 includes epoxy composite samples with varying ZnO levels to determine the effect of inorganic filler level on AO durability. And, a variety of samples were flown to characterize AO scattering and AO undercutting processes. All four PCE experiments include samples to provide better insight into radiation durability of polymers and composites. The MISSE-9 PCE-1 includes Teflon FEP tensile samples flown in the wake and zenith direction so variations in radiation exposure from the different flight directions can provide insight into radiation induced embrittlement of Teflon FEP. Teflon FEP tensile samples were also flown in the wake direction as part of the MISSE-13 PCE-4. In addition, shape memory alloys, shape memory composites, melanin based composites, stressed and unstressed gossamer sun shield materials, coated and uncoated docking seal samples, and new solar cell cover slides were flown for space radiation durability and/or shielding assessment. This paper provides an overview of Glenn’s PCE 1-4 MISSE-FF experiments and provides initial post-flight observations and results.

atomic oxygen↗

Space Environmental Exposure of the MISSE 9-15 Polymers and Composites Experiment 1-4 (PCE 1-4)

Spacecraft in low Earth orbit (LEO) are subjected to harsh environmental conditions, including radiation (cosmic rays, ultraviolet (UV), x-ray and charged particle radiation), micrometeoroids and orbital debris, temperature extremes, thermal cycling, and atomic oxygen (AO). These environmental exposures can result in erosion, embrittlement and optical property degradation of susceptible materials threatening spacecraft performance and durability. To increase our understanding of effects such as AO erosion and radiation induced embrittlement of spacecraft materials, NASA Glenn Research Center has developed a series of experiments that were flown as part of the Materials International Space Station Experiment (MISSE) missions on the exterior of the International Space Station (ISS). These experiments have provided critical space environmental durability data such as AO erosion data of polymers and composites, and radiation induced mechanical property degradation of spacecraft insulation materials, after long term space exposure. Recently, four Glenn experiments with 365 flight samples were flown on ISS’s MISSE-Flight Facility (MISSE-FF). These experiments are the Polymers and Composites Experiment-1 (PCE-1) flown as part of the MISSE-9 mission, the PCE-2 flown as part of the MISSE-10 mission, the PCE-3 flown as part of the MISSE-12 and MISSE-15 missions, and the PCE-4 flown as part of the MISSE-13 mission. This paper provides details on the space environment exposure of Glenn’s PCE 1-4 flight samples. Passive samples were flown in each flight orientation for post-flight AO fluence determination and on-orbit contamination analyses. Solar exposure estimates were computed by Aegis Aerospace, Inc. The environment exposure details include the total space vacuum duration, time on the MISSE-FF, the direct space exposure duration, the AO fluence and the computed mission Equivalent Sun Hours (ESH) solar exposure. Typical on-orbit temperatures are also provided along with a summary of analyses of PCE 1-4 contamination witness samples. Knowledge of the space environmental exposure of the PCE 1-4 flight samples is crucial for flight data interpretation.

Atomic oxygen↗

Building America Case Study: Field Testing an Unvented Roof with Asphalt Shingles in a Cold Climate, Boilingbrook, Illinois

Insulating roofs with dense-pack cellulose (instead of spray foam) has moisture risks, but is a lower cost approach. If moisture risks could be addressed, buildings could benefit from retrofit options, and the ability to bring HVAC systems within the conditioned space. Test houses with unvented roof assemblies were built to measure long-term moisture performance, in the Chicago area (5A) and the Houston area (2A). The Chicago-area test bed had seven experimental rafter bays, including a 'control' vented compact roof, and six unvented roof variants with cellulose or fiberglass insulation. The interior was run at 50% RH. All roofs except the vented cathedral assembly experienced wood moisture contents and RH levels high enough to constitute failure. Disassembly at the end of the experiment showed that the unvented fiberglass roofs had wet sheathing and mold growth. In contrast, the cellulose roofs only had slight issues, such as rusted fasteners and sheathing grain raise. The Houston-area roof was an unvented attic insulated with spray-applied fiberglass. Most ridges and hips were built with a 'diffusion vent' detail, capped with vapor permeable roof membrane. Some ridge sections were built as a conventional unvented roof, as a control. In the control unvented roofs, roof peak RHs reached high levels in the first winter; as exterior conditions warmed, RHs quickly fell. In contrast, the diffusion vent roofs had drier conditions at the roof peak in wintertime, but during the summer, RHs and MCs were higher than the unvented roof (albeit in the safe range).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spray Foam in Accessible Spaces: Best Practices and Case Studies for Retrofit in Mixed-Humid Climates

Heating and cooling the house is one of the homeowners major expenses. Reducing these costs, saving energy, and creating a healthier, more comfortable indoor environment are good reasons to consider improving the building thermal envelope. Improvements usually consider increasing the amount of insulation, reducing the infiltration of outside air, and controlling moisture in existing buildings. This report describes the use of spray foam materials to insulate, seal, and control moisture. This discussion is limited to treating areas that are accessible. What is accessible, however, can vary depending on the type of renovation. If the building has been gutted or exterior surfaces removed, there are more options. This report will look at areas to consider for spray foam application and discuss the types of spray foams available and their uses. A number of case studies are presented to show the effectiveness of this retrofit in existing houses based on performance data.

Best practices↗

Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-Humid Climates

Insulating roofs with dense-pack cellulose (instead of spray foam) has moisture risks, but is a lower cost approach. If moisture risks could be addressed, buildings could benefit from retrofit options, and the ability to bring HVAC systems within the conditioned space. Test houses with unvented roof assemblies were built to measure long-term moisture performance, in the Chicago area (5A) and the Houston area (2A). The Chicago-area test bed had seven experimental rafter bays, including a control vented compact roof, and six unvented roof variants with cellulose or fiberglass insulation. The interior was run at 50% RH. All roofs except the vented cathedral assembly experienced wood moisture contents and RH levels high enough to constitute failure. Disassembly at the end of the experiment showed that the unvented fiberglass roofs had wet sheathing and mold growth. In contrast, the cellulose roofs only had slight issues, such as rusted fasteners and sheathing grain raise. The Houston-area roof was an unvented attic insulated with spray-applied fiberglass. Most ridges and hips were built with a diffusion vent detail, capped with vapor permeable roof membrane. Some ridge sections were built as a conventional unvented roof, as a control. In the control unvented roofs, roof peak RHs reached high levels in the first winter; as exterior conditions warmed, RHs quickly fell. In contrast, the diffusion vent roofs had drier conditions at the roof peak in wintertime, but during the summer, RHs and MCs were higher than the unvented roof (albeit in the safe range).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Steady flows at the top of the core from geomagnetic field models - The steady motions theorem

It is demonstrated that the steady tangential velocity at the closed surface of a perfect-fluid conductor bounded by a rigid impenetrable exterior can be uniquely determined from knowledge of the normal component of the time-varying magnetic-flux density on the surface. In the context of a simple earth model consisting of an electrically insulating mantle surrounding a perfectly conducting core, the assumption of steady flow provides enough extra information to eliminate the toroidal ambiguity and to allow derivation of a unique global flow at the top of the core from a model of the geomagnetic field.

Voorhies, C. V.↗

The MISSE 7 Flexural Stress Effects Experiment After 1.5 Years of Wake Space Exposure

Low Earth orbit space environment conditions, including ultraviolet radiation, thermal cycling, and atomic oxygen exposure, can cause degradation of exterior spacecraft materials over time. Radiation and thermal exposure often results in bond- breaking and embrittlement of polymers, reducing mechanical strength and structural integrity. An experiment called the Flexural Stress Effects Experiment (FSEE) was flown with the objective of determining the role of space environmental exposure on the degradation of polymers under flexural stress. The FSEE samples were flown in the wake orientation on the exterior of International Space Station for 1.5 years. Twenty-four samples were flown: 12 bent over a 0.375 in. mandrel and 12 were over a 0.25 in. mandrel. This was designed to simulate flight configurations of insulation blankets on spacecraft. The samples consisted of assorted polyimide and fluorinated polymers with various coatings. Half the samples were designated for bend testing and the other half will be tensile tested. A non-standard bend-test procedure was designed to determine the surface strain at which embrittled polymers crack. All ten samples designated for bend testing have been tested. None of the control samples' polymers cracked, even under surface strains up to 19.7%, although one coating cracked. Of the ten flight samples tested, seven show increased embrittlement through bend-test induced cracking at surface strains from 0.70%to 11.73%. These results show that most of the tested polymers are embrittled due to space exposure, when compared to their control samples. Determination of the extent of space induced embrittlement of polymers is important for designing durable spacecraft.

Snow, Kate E.↗

Affordable Solid Panel “Perfect Wall” System

This report, Affordable Solid Panel “Perfect Wall” System , reviews and analyzes a novel building assembly—which features an innovative large format Solid Panel Structure and utilizes the “perfect wall” concept of having high-performance moisture and thermal control layers on the exterior of the structural components.

14 SOLAR ENERGY↗

Minimizing User Burden in Building Energy Analysis

Infrared (IR) imagery can provide valuable data to building energy auditors and the developers of Building Energy Models (BEM). IR by itself is not a panacea to the challenges facing energy auditors and modelers, but when combined with other techniques and Open Studio software, IR can play an important role in the minimization of the burden of creating building energy models and the diagnosing of building energy problems. While IR can be used to detect and quantify many aspects of a building’s thermal and energy performance, in Phase I we focused on a single capability: determining the R value of exterior walls. Two key attributes of using IR methods for R value determination is that IR methods measure the actual, installed performance in-situ – as opposed to relying on manufacturer or handbook values – and they can integrate performance over a wide area and thus can accurately account for thermal bridging and spatial anomalies such as “spotty” insulation installation. There is a trade between user burden and accuracy when using IR to determine a wall’s R value. The least burdensome approach is computing R values from a single IR snapshot. The most burdensome method we considered was to combine IR images with thermocouple and heat flux sensor (HFS) measurements made over the course of several days. The more effort users expend in making the measurements, the more accurate and robust the method becomes. Through a series of field tests at the ThermoAnalytics Inc. (TAI) HQ at Calumet, MI and a simulation of a 1980s era office building in Flagstaff, AZ we investigated methods to compute the R value of exterior walls using data from IR cameras, thermocouples and heat flux sensors. To compute R values the heat flux through the wall, along with temperatures on either side of the wall, must be known, modeled, or estimated – and the temperature difference through the wall should be at least 10 C. If only outdoor IR images are used in the method, the inside ambient air temperature must be estimated, and a simulation model created to predict heat fluxes and the indoor wall temperature. The accuracy of the resulting R value depends on the accuracy of the simulation and the assumptions it employs. Applying thermocouple sensors, either as iButtons or as part of a wireless sensor network, to the walls allows for the acquisition of temperatures over time. The longer the duration of the measurements, the more accurate and robust the method will be. Even with this level of measurement effort, modeling is still required to calculate the heat flux through the wall. The addition of a heat flux sensor alleviates the need for any modeling, and that results in improved accuracy. Driving the accuracy of the methods are several factors that can be quantified. How well are the wall surface temperatures known? Modeling the heat flux through walls requires knowing the details of the surrounding radiant environment and the heat transfer due to convection. How well are these boundary conditions known? Even when the heat flux is measured, error can arise when some of the measured heat is not conducted through the wall but rather goes into the thermal mass of the wall. Thermal mass effects occur when conditions and the heat flux values are fluctuating. A technique that is not robust will suffer in accuracy when these fluctuations occur. The R value determination method must be incorporated into the Open Studio process. In our proposed process, IR images and other measured sensor data are input into a module that would send R value estimates to a building library developed by team member Skidmore, Owings, & Merrill (SOM). This library of parameterized building models would use these R values along with information about the building’s age, type, and location to query the Open Studio BCL to identify the most likely constructions for walls, roof, and windows. Being based on the IMF feature of Energyplus, the SOM building library can quickly produce Energyplus models of buildings based on a limited number of user inputs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential benefits and optimization of cool-coated office buildings: A case study in Chongqing, China

Increasing envelope facet albedos considerably reduces solar heat gain, thus yielding building cooling energy savings. Few studies have explored the potential benefits of utilizing cool coatings on building envelopes (“cool-coated buildings”) based on life-cycle cost analysis. A holistic approach integrating the field testing, building energy simulation, and a 20-year life-cycle-based optimization was developed to explore cool-coated building performance and the maximum net savings of optimal building envelope retrofit and design. Experimental results showed that applying cool coatings to a west wall of an office building in Chongqing, China reduced its exterior surface temperature by up to 9.3 °C in summer. Additionally, simulation results showed that in Chongqing, making the roof and walls cool could reduce annual HVAC electricity use by up to 11.9% in old buildings (with poorly insulated envelopes) and up to 5.9% in new buildings. Retrofitting old buildings with a cool roof provided the net savings per modified area with present values up to 42.8 CNY/m2; retrofitting a new building with a cool roof or cool walls was not cost-effective. Optimizing both envelope insulation and envelope albedo can achieve 5.6 times the net savings of optimizing the insulation only, and 1.6 times that of optimizing albedo only.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Safe Response to Renewable Energy Hazards

The International Association of Fire Fighters (IAFF) and Underwriters Laboratories, LLC (UL) in conjunction with UL Solutions initiated a joint project in 2022 under an agreement with the United States Department of Energy-Office of Energy Efficiency and Renewable Energy (DOE-EERE). This project focused on two separate and important initiatives related to energy efficiency in residential buildings. Initiative 1: Fire Performance on Energy Efficient Exterior Walls. Initiative 2: Firefighting Tactics in Residential Properties with Building Energy Storage Systems (BESS). The project’s first initiative addresses concerns surrounding new technologies with enhanced, energy-efficient exterior walls installed on residential properties. The concerns of fire rapidly traveling vertically up the exterior of these walls were examined. This addressed a growing concern from the first responder community that many times, the fires on the exterior of residential buildings have already evolved into an attic fire by the time of arrival – making it problematic to address the fire scenario. The test plan for Initiative 1 incorporated a modified version of an American Society for Testing and Materials (ASTM) test method, ASTM E2707, Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure, as the foundation of the research. The test method involved a wall structure intended to represent retrofit construction to evaluate how fire would spread vertically or laterally. The second aspect of the UL-IAFF Project focuses on the fire service response to Residential Battery Energy Storage System (RBESS) incidents. These simulation tests were constructed in the large-scale fire test facility at UL Solutions’ Northbrook, IL campus. A baseline test was conducted that involved a test structure with no batteries—shelving units populated with standardized commodities, representing a typical garage with cellulosic and plastic contents. Three additional tests have been conducted to generate data with the contribution of energy storage system (ESS) batteries to compare fire and explosion hazards against the baseline test. Through this work, fire service tactical considerations can be explored. From the data, the team can determine 1) the visual indicators of a residential fire that has involved an RBESS (or, potentially, other large batteries) and 2) the impact of fire service-initiated ventilation of the structure on the fire conditions and explosion risks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Variables Influenced by Thermal Mass and its Impact on Energy Performance in Buildings

There is no question that thermal mass has an impact on the energy performance of buildings, both the peak energy demand and overall consumption. However, there are many variables that contribute to and influence the impact of mass on energy performance. This paper is the result of an analytic study that evaluated thermal mass and associated building envelope energy performance for commercial and residential prototype buildings. Relationships between thermal mass, insulation levels, internal gains, outdoor climate, building usage and user preferences were studied. In this paper, authors analyzed how these variables interact and investigated optimized conditions for utilization of thermal mass. It is also discussed how air conditioning operation, exterior and interior loads, and thermostat set points impact the usefulness of thermal mass in a building to favorably impact peak demand and energy savings. Existing methods and approaches to evaluate the impact of thermal mass are discussed and a preferred design approach is presented to estimate the impact of thermal mass on energy peak demand and overall energy consumption under both heating and cooling conditions.

Pallin, Simon B.↗