Search NASA⌕ Search

SEARCH · Search NASA

Results for “Emittance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Verification of the AWA Photoinjector Beam Parameters Required for a Transverse-to-Longitudinal Emittance Exchange Experiment

A transverse-to-longitudinal emittance exchange experiment is in preparation at the Argonne Wakefield Accelerator (AWA). The experiment aims at exchanging a low ({var_epsilon}{sub z} < 5 {micro}m) longitudinal emittance with a large ({var_epsilon}{sub x} > 15 {micro}m) transverse horizontal emittance for a bunch charge of {approx}100 pC. Achieving such initial emittance partitioning, though demonstrated via numerical simulations, is a challenging task and needs to be experimentally verified. In this paper, we report preliminary emittance measurements of the beam in the transverse and longitudinal planes performed at {approx}12 MeV. The measurements are compared with numerical simulations.

43 PARTICLE ACCELERATORS↗

Space Charge Suppression for Uneven Emittances

The intensity of low and intermediate energy accelerators and storage rings is limited by space charge effects. An increase of the space charge tune shift may lead to lifetime degradation and coherent instability. A method to suppress the space charge effect is suggested for a beam with two uneven emittances. It has been shown that for a beam with uneven emittances, use of the circular optics makes the space charge tune shift equal to its planar value in the large-emittance direction. This removes a limit on the smaller emittance from the space charge side. Thus, since flat beams can be extremely bright, they could find their use in various applications: ion-electron colliders, nuclear fusion, medicine, and others. One additional possibility for the use of these beams relates to the fact that in a matched solenoid the CAM-dominated beam is transformed into a parallel beam. This transformation is essential for relativistic electron cooling of antiprotons at Fermilab. The two transverse emittances can be made significantly different either by means of a special injection procedure (painting), or by cooling, or by extraction of the beam from a magnetized gun. In any case, use of the circular optics appears to open a special possibility for extremely bright beams.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental study of coherent synchrotron radiation in the emittance exchange line at the A0-photoinjector

Next generation accelerators will require a high current, low emittance beam with a low energy spread. Such accelerators will employ advanced beam conditioning systems such as emittance exchanger to manipulate high brightness beams. One of the goals of the Fermilab A0 photoinjector is to investigate the transverse to longitudinal emittance exchange principle. Coherent synchrotron radiation could limit high current operation of the emittance exchanger. In this paper, we report on the preliminary experimental and simulation study of the coherent synchroton radiation (CSR) in the emittance exchange line at A0 photoinjector.

43 PARTICLE ACCELERATORS↗

Sub‐Diffraction Correlation of Quantum Emitters and Local Strain Fields in Strain‐Engineered WSe 2 Monolayers

Strain-engineering in atomically thin metal dichalcogenides is a useful method for realizing single-photon emitters (SPEs) for quantum technologies. Correlating SPE position with local strain topography is challenging due to localization inaccuracies from the diffraction limit. Currently, SPEs are assumed to be positioned at the highest strained location and are typically identified by randomly screening narrow-linewidth emitters, of which only a few are spectrally pure. In this work, hyperspectral quantum emitter localization microscopy is used to locate 33 SPEs in nanoparticle-strained WSe 2 monolayers with sub-diffraction-limit resolution (≈30 nm) and correlate their positions with the underlying strain field via image registration. In this system, spectrally pure emitters are not concentrated at the highest strain location due to spectral contamination; instead, isolable SPEs are distributed away from points of peak strain with an average displacement of 240 nm. These observations point toward a need for a change in the design rules for strain-engineered SPEs and constitute a key step toward realizing next-generation quantum optical architectures.

2D material↗

Solution-phase sample-averaged single-particle spectroscopy of quantum emitters with femtosecond resolution

Here, the development of many optical quantum technologies depends on the availability of solid-state single quantum emitters with near-perfect optical coherence. However, a standing issue that limits systematic improvement is the significant sample heterogeneity and lack of mechanistic understanding of microscopic energy flow at the single emitter level and ultrafast timescales. Here we develop solution-phase single-particle pump-probe spectroscopy with photon correlation detection that captures sample-averaged dynamics in single molecules and/or defect states with unprecedented clarity at femtosecond resolution. We apply this technique to single quantum emitters in two-dimensional hexagonal boron nitride, which suffers from significant heterogeneity and low quantum efficiency. From millisecond to nanosecond timescales, the translation diffusion, metastable-state-related bunching shoulders, rotational dynamics, and antibunching features are disentangled by their distinct photon-correlation timescales, which collectively quantify the normalized two-photon emission quantum yield. Leveraging its femtosecond resolution, spectral selectivity and ultralow noise (two orders of magnitude improvement over solid-state methods), we visualize electron-phonon coupling in the time domain at the single defect level, and discover the acceleration of polaronic formation driven by multi-electron excitation. Corroborated with results from a theoretical polaron model, we show how this translates to sample-averaged photon fidelity characterization of cascaded emission efficiency and optical decoherence time. Our work provides a framework for ultrafast spectroscopy in single emitters, molecules, or defects prone to photoluminescence intermittency and heterogeneity, opening new avenues of extreme-scale characterization and synthetic improvements for quantum information applications.

36 MATERIALS SCIENCE↗

A high-current microwave ion source with permanent magnet and its beam emittance measurement

The progress of a 2.45 GHz high-current microwave ion source with permanent magnet for T(d,n){sup 4}He reaction neutron generator is reported in this paper. At 600 W microwave power and 22 kV extraction voltage, 90 mA peak hydrogen ion beam is extracted from a single aperture of 6 mm diameter. The beam emittance is measured using a simplified pepper-pot method. The (x,x{sup '}) emittance and the (y,y{sup '}) emittance for 14 keV hydrogen ion beam are 55.3{pi} and 58.2{pi} mm mrad, respectively. The normalized emittances are 0.302{pi} and 0.317{pi} mm mrad, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a pepper-pot device to determine the emittance of an ion beam generated by electron cyclotron resonance ion sources

This paper describes the recent development and commissioning of a pepper-pot emittance meter at the Lawrence Berkeley National Laboratory (LBNL). It is based on a potassium bromide (KBr) scintillator screen in combination with a charged coupled device camera. Pepper-pot scanners record the full four-dimensional transverse phase space emittances which are particularly interesting for electron cyclotron resonance ion sources. The strengths and limitations of evaluating emittances using optical pepper-pot scanners are described and systematic errors induced by the optical data acquisition system will be presented. Light yield tests of KBr exposed to different ion species and first emittance measurement data using ion beams extracted from the 6.4 GHz LBNL electron cyclotron resonance ion source are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of transverse ion beam emittance generated by high current ion sources at the GSI test injector facility HOSTI

The first emittance measurements with a new test injector facility (HOSTI) at GSI, designed for optimization of high current beam injection scheme, are discussed. The emittance of the ion beam (88 kV, Ar{sup 1+} ions) was investigated as a function of various parameters related to the ion source, extraction, and postacceleration systems and the optimum parameters for future low energy beam transport line are concluded. The preliminary results of the emittance measurements with superconducting solenoid are presented. The influence of the focusing strength as well as the longitudinal field shape of the solenoid on the beam emittance is described.

43 PARTICLE ACCELERATORS↗

Emittance studies of the Spallation Neutron Source external-antenna H{sup -} ion source

A new Allison-type emittance scanner has been built to characterize the ion sources and low energy beam transport systems at Spallation Neutron Source. In this work, the emittance characteristics of the H{sup -} beam produced with the external-antenna rf-driven ion source and transported through the two-lens electrostatic low energy beam transport are studied. The beam emittance dependence on beam intensity, extraction parameters, and the evolution of the emittance and twiss parameters over beam pulse duration are presented.

43 PARTICLE ACCELERATORS↗

Laser Assisted Emittance Exchange

We describe here the laser assisted emittance exchange (LAEE) technique. A laser operating in the transverse mode (TEM10 or TEM01) is used to interact with the electron beam in a dispersive region and to initiate the transverse-to-longitudinal emittance exchange. It is shown that with the LAEE one can generate an electron beam with ultralow transverse emittance, which allows one to significantly bring down the size of an X-ray free electron laser (FEL) and greatly extend the availability of these light sources. The technique can also be used to enhance the performances of X-ray FELs in storage rings. The timing and energy jitter problems for the standard emittance exchange and LAEE techniques are also discussed.

43 PARTICLE ACCELERATORS↗

An asymmetric emittance electron source for the GALAXIE dielectric-laser accelerator injector

The GALAXIE project is a program to develop an all-optical, very high field accelerator and undulator integrated SASE FEL system based on dielectric laser-excited structures that support >GV/m fields. These structures are very wide in one direction to allow adequate charge given beam loading considerations, but also having small (subwavelength) apertures in the narrow direction. Such small vertical dimensions yield strict restrictions on the emittance in this direction, while no such constraint exists in the wide transverse direction. However, the overall beam brightness is restricted by the performance requirements on the FEL. To meet these demands, we are studying a very high field gun with a magnetized cathode, yielding a beam with angular momentum content. This beam is then subject to a skew-quad triplet that splits the emittances; this process is reversed to give a round beam after acceleration. This symmetric emittance beam avoids gain-degrading multiple-transverse-mode operation of the FEL, which also demands that the effects of the angular momentum in the beam be mitigated. In this paper we discuss the RF design of an X-band gun to be operated at {approx}200 MV/m peak field giving a 1 pC magnetized beam with unprecedented brightness. We examine the design of the focusing and skew-quad systems, investigating the associated beam dynamics and efficacy of emittance splitting.

43 PARTICLE ACCELERATORS↗

Demonstration of cathode emittance dominated high bunch charge beams in a DC gun-based photoinjector

We present the results of transverse emittance and longitudinal current profile measurements of high bunch charge (≥100 pC) beams produced in the DC gun-based Cornell energy recovery linac photoinjector. In particular, we show that the cathode thermal and core beam emittances dominate the final 95% and core emittances measured at 9–9.5 MeV. Additionally, we demonstrate excellent agreement between optimized 3D space charge simulations and measurement, and show that the quality of the transverse laser distribution limits the optimal simulated and measured emittances. These results, previously thought achievable only with RF guns, demonstrate that DC gun based photoinjectors are capable of delivering beams with sufficient single bunch charge and beam quality suitable for many current and next generation accelerator projects such as Energy Recovery Linacs and Free Electron Lasers.

43 PARTICLE ACCELERATORS↗

Experimental Studies on Coherent Synchrotron Radiation at an Emittance Exchange Beamline

One of the goals of the Fermilab A0 photoinjector is to experimentally investigate the transverse to longitudinal emittance exchange (EEX) principle. Coherent synchrotron radiation in the emittance exchange line could limit the performance of the emittance exchanger at short bunch lengths. In this paper, we present experimental and simulation studies of the coherent synchrotron radiation (CSR) in the emittance exchange line at the A0 photoinjector. We report on time-resolved CSR studies using a skew-quadrupole technique. We also demonstrate the advantages of running the EEX with an energy chirped beam.

43 PARTICLE ACCELERATORS↗

Absolute beam emittance measurements at RHIC using ionization profile monitors

In the past, comparisons between emittance measurements obtained using ionization profile monitors, Vernier scans (using as input the measured rates from the zero degree counters, or ZDCs), the polarimeters and the Schottky detectors evidenced significant variations of up to 100%. In this report we present studies of the RHIC ionization profile monitors (IPMs). After identifying and correcting for two systematic instrumental errors in the beam size measurements, we present experimental results showing that the remaining dominant error in beam emittance measurements at RHIC using the IPMs was imprecise knowledge of the local beta functions. After removal of the systematic errors and implementation of measured beta functions, precise emittance measurements result. Also, consistency between the emittances measured by the IPMs and those derived from the ZDCs was demonstrated.

43 PARTICLE ACCELERATORS↗

Compliance with High-Intensity Radiated Fields Regulations - Emitter's Perspective

NASA's Deep Space Network (DSN) uses high-power transmitters on its large antennas to communicate with spacecraft of NASA and its partner agencies. The prime reflectors of the DSN antennas are parabolic, at 34m and 70m in diameter. The DSN transmitters radiate Continuous Wave (CW) signals at 20 kW - 500 kW at X-band and S-band frequencies. The combination of antenna reflector size and high frequency results in a very narrow beam with extensive oscillating near-field pattern. Another unique feature of the DSN antennas is that they (and the radiated beam) move mostly at very slow sidereal rate, essentially identical in magnitude and at the opposite direction of Earth rotation.The DSN is in the process of revamping its documentation to provide analysis of the High Intensity Radiation Fields (HIRF) environment resulting from radio frequency radiation from DSN antennas for comparison to FAA regulations regarding certification of HIRF protection as outlined in the FAA regulations on HIRF protection for aircraft electrical and electronic systems (Title 14, Code of Federal Regulations (14 CFR) [section sign][section sign] 23.1308, 25.1317, 27.1317, and 29.1317).This paper presents work done at JPL, in consultation with the FAA. The work includes analysis of the radiated field structure created by the unique DSN emitters (combination of transmitters and antennas) and comparing it to the fields defined in the environments in the FAA regulations. The paper identifies areas that required special attention, including the implications of the very narrow beam of the DSN emitters and the sidereal rate motion. The paper derives the maximum emitter power allowed without mitigation and the mitigation zones, where required.Finally, the paper presents summary of the results of the analyses of the DSN emitters and the resulting DSN process documentation.

DSN emitters↗

On the Importance of Symmetrizing RF Coupler Fields for Low Emittance Beams

The input power of accelerator structure is normally fed through a coupling slot(s) on the outer wall of the accelerator structure via magnetic coupling. While providing perfect matching, the coupling slots may produce non-axial-symmetric fields in the coupler cell that can induce emittance growth as the beam is accelerated in such a field. This effect is especially important for low emittance beams at low energies such as in the injector accelerators for light sources. In this paper, we present studies of multipole fields of different rf coupler designs and their effect on beam emittance for an X-band photocathode gun being jointly designed with LLNL, and X-band accelerator structures. We will present symmetrized rf coupler designs for these components to preserve the beam emittance.

43 PARTICLE ACCELERATORS↗

Transverse Beam Emittance Measurements of a 16 MeV Linac at the Idaho Accelerator Center

A beam emittance measurement of the 16 MeV S-band High Repetition Rate Linac (HRRL) was performed at Idaho State University's Idaho Accelerator Center (IAC). The HRRL linac structure was upgraded beyond the capabilities of a typical medical linac so it can achieve a repetition rate of 1 kHz. Measurements of the HRRL transverse beam emittance are underway that will be used to optimize the production of positrons using HRRL's intense electron beam on a tungsten converter. In this paper, we describe a beam imaging system using on an OTR screen and a digital CCD camera, a MATLAB tool to extract beamsize and emittance, detailed measurement procedures, and the measured transverse emittances for an arbitrary beam energy of 15 MeV.

43 PARTICLE ACCELERATORS↗

Analysis of Slice Transverse Emittance Evolution ina Photocathode RF Gun

The slice transverse emittance of an electron beam is of critical significance for an x-ray FEL. In a photocathode RF gun, the slice transverse emittance is not only determined by the emission process, but also influenced strongly by the non-linear space charge effect. In this paper, we study the slice transverse emittance evolution in a photocathode RF gun using a simple model that includes effects of RF acceleration, focusing, and space charge force. The results are compared with IMPACT-T space charge simulations and may be used to understand the development of the slice emittance in an RF gun.

43 PARTICLE ACCELERATORS↗