Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Conservation Measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Residential Water Heating Demand Side Management (DSM) - South Africa

The electricity crisis in South Africa has deteriorated significantly, with the country experiencing frequent and prolonged rolling blackouts. These outages have severe economic repercussions, leading to decreased growth and productivity. Demand Side Management (DSM), particularly focusing on electric water heaters due to their significant energy consumption and peak demand contribution, is identified as a key strategy. The study aims to assess opportunities for DSM programs targeting water heating to reduce energy consumption and peak demand. It entails developing a bottom-up simulation model to establish a baseline scenario of water heating electricity load demand in 2023 and 2033, identifying technologies for energy reduction, estimating the impacts of a selected number of measures and providing recommendations to inform policy makers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Lighting Application Efficacy Measurement Framework

Lighting significantly contributes to electricity consumption in buildings. The most widely used measure of lighting energy efficiency, luminous efficacy, quantifies only the intensity of light generated by light sources, weighted by the spectral sensitivity of the human visual system (i.e., the energy efficiency of individual lighting devices). However, luminous efficacy does not fully address the use of lighting in architectural spaces. To address these limitations, we developed a framework to framework to calculate lighting application efficacy (LAE), the relationship between the electrical power consumed by lighting hardware, and the amount of light that contributes to the visual perception of building occupants. The proposed LAE framework is based on the primary pathway of light in architectural settings: the generation and emission of light from a luminaire, the travel of the light throughout the space and into the eyes of occupants, and the process of visual perception. The project’s primary outputs are a method for measuring lighting application efficacy and a framework for facilitating future research to improve the metric.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential Energy, Demand, Emissions, and Cost Savings Distributions for Buildings in a Utility’s Service Area

Several companies, universities, and national laboratories are developing urban-scale energy modeling that allows the creation of a digital twin of buildings for the simulation and optimization of real-world, city-sized areas. Prior to simulation-based assessment, a baseline of savings for a set of utility-defined use cases was established to clarify the initial business case for specific energy efficient building technologies. In partnership with a municipal utility, 178,337 OpenStudio and EnergyPlus models of buildings in the utility’s 1400 km 2 service area were created, simulated, and assessed with measures for quantifying energy, demand, cost, and emissions reductions of each building. The method of construction and assumptions behind these models is discussed, definitions of example measures are provided, and distribution of savings across the building stock is provided under a maximum technical adoption scenario.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On the Stability of Power Transmission Systems Under Persistent Inverter Attacks: A Bi-Linear Matrix Approach

We investigate the stability and robustness properties of a power transmission system under persistent deceiving attacks on inverter-interfaced energy resources. The attacks can corrupt the damping coefficients in the inverters' controllers and measurements of the frequency at the points of coupling. Leveraging tools from hybrid dynamical systems theory, we characterize a broad family of persistent (and not necessarily periodic) attacks acting on the inverters, under which the stability properties of the transmission system can be shown to not be compromised. To address potentially conservative conditions identified through conventional bounding techniques, sufficient conditions on the average activation time of the attacks are identified via Lyapunov theory, as well as the formulation and solution of a class of bilinear matrix inequalities (BMI). The results are obtained for constant and slowly time-varying loads via input-to-state stability (ISS) tools. Numerical simulations on the IEEE 39-bus test system are also presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shifting in Large Offices

This documentation focuses on a single end-use savings shape measure - thermostat control for load shifting. The thermostat control for load shifting measure applies heating and cooling temperature setpoint adjustment for pre-conditioning before the peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start time of the peak window, and then adjusts the thermostat cooling or heating setpoints by a specified offset value from original schedules to precool or preheat the space , for a specified length of time before the start of peak window, and thus shifts load in the peak window to the pre-conditioning period. The measure is flexible and allows users to adjust the heating and cooling offset values and length of pre-conditioning period, but for this study, the load shifting strategy is applied as pre-cooling only (adjusting only cooling setpoints). The default adjustment for cooling setpoints is set to -1 degrees Celsius , and the default duration of pre-cooling is 1 hour. This measure is applicable to large offices equipped with electric HVAC system, which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shifting measure demonstrates -1% daily peak demand reduction and 0% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A detailed chemical kinetic modeling and experimental investigation of the low- and high-temperature chemistry of n-butylcyclohexane

Chemical kinetic models of gasoline, jet, and diesel fuels and their mixtures with bioderived fuels are needed to assess fuel property effects on efficiency, emissions, and other performance metrics in internal combustion and gas turbine engines. As these real fuels have too many fuel components to be included in a chemical kinetic model, surrogate fuels containing fewer components are used to represent them. These surrogate fuels mimic the chemical classes or molecular structures contained in the real fuel. One of the important chemical classes in gasoline, jet, and diesel fuels comprises cyclohexanes. Cyclohexanes comprise about 30% or more by weight in diesel fuel. Also, Mueller et al proposed n-butylcyclohexane (nBCH) as a component in a nine-component surrogate palette to represent the ignition properties, distillation curve, density, and molecular structures of a diesel certification fuel. Herein, experimental measurements of the ignition delay times (IDTs) of nBCH in a shock tube and in a rapid compression machine are reported over a wide range of temperature, pressure, and equivalence ratio important for enabling the validation of a chemical kinetic model for nBCH for combustion in diesel engines. The range of conditions are temperatures of 630–1420 K, pressures of 10, 30, and 50 bar, and equivalence ratios of 0.3, 0.5, 1.0, and 2.0 in ‘air’. A detailed chemical model is developed for nBCH to simulate its ignition at both low and high-temperature conditions and at relevant elevated pressures. The experimentally measured IDTs are used to improve and validate the chemical kinetic model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tracer gas test in Net-Zero Energy Residential Test Facility

The Net-Zero Energy Residential Test Facility (NZERTF) at NIST was built in 2012 to support the development and adoption of cost-effective net-zero energy designs, technologies, and construction methods. It is two-story, and has four bedrooms, three bathrooms, and an open living room, dining room, and kitchen space. The NZERTF also has a basement and attic, both located within the conditioned space because the thermal and air-moisture barriers encompass the basement walls and attic roof. Transfer grilles link the living spaces to these two zones. The central heating and cooling system includes an air-toair heat pump, which delivers air to the basement, first and second floors. The heat pump has a cooling capacity of 7.6 kW and a heating capacity of 7.8 kW. The indoor unit is in the basement and ductwork runs along the basement ceiling. A balanced heat recovery ventilator (HRV) is installed in the basement and has its own dedicated ductwork. The HRV supplies 47 L/s of outdoor air to the house, with supplies on the first floor (in the kitchen/dining area) and in each of the three second-floor bedrooms. Air from the first-floor bathroom and both second-floor bathrooms is returned to the HRV before being exhausted, though the HRV was turned off during the tests. The house also has a range hood exhaust and a clothes dryer exhaust, both of which were turned off for the tests. The temperature of the house was measured and the operation of the space conditioning system, including its recirculating air distribution fan, were controlled by a commercially available thermostat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart Methane Emission Detection System Development (Final Report)

Working with the Department of Energy's National Energy Technology Laboratory, Southwest Research Institute® (SwRI®) developed a system to identify methane leaks reliably, accurately, and autonomously at critical midstream sections of the natural gas distribution network in real-time for the purpose of mitigating methane emissions using Optical Gas Imaging (OGI) cameras. SwRI's Smart Leak Detection – Methane (SLED/M) adds a high degree of automation to the process of methane leak detection to minimize sources of human error, minimize response time to a leak event, and maximize midstream visibility. Furthermore, SwRI has been working towards integrating Quantitative OGI (QOGI) capabilities into this existing technology. By leveraging Deep Learning, SwRI now has the capability to estimate fugitive emission leak rates quickly and reliably, which allows operators to detect emissions, quantify leak rate, prioritize repairs, and validate the repairs in a single instrument. The next generation QOGI technology leverages the same cameras used in Leak Detection and Repair (LDAR) programs, with improvements in safety and speed for traditional quantification-based repairs, ultimately leading to less overhead cost for the operators. The goals for this research were to develop two types of models with the following goals: Run in real-time on the edge (≥ 12 Hz), Classification: Achieve less than 5% false positive detection, Classification: Achieve ≥ 95% methane plume detection rate, Regression: achieve ≤ 10 standard cubic feet per hour (scfh) prediction > 70% of the time. In order to achieve these results, multiple infrared (IR) and other sensors were investigated in tandem with the midwave IR (MWIR) OGI to provide additional information to train the underlying models. Information on atmospheric conditions including humidity, temperature, pressure, and solar radiation was provided by a weather station. Several machine learning and deep learning architectures and methods, including looking at quantized classification networks and regressions networks, were explored. As further data was collected, curated, and labeled, it allowed for more refined regressive networks to be adequately trained, leading to better insight into the true flow rates being observed. An important valuable deliverable of this research effort was the development of an advanced network which underwent multiple iterations capable of giving a continuous output. The current network has a predicted mean average percentage error (MAPE) of 12.3% just outside our target goal of 10.00%, but an accuracy of 97.78% at ±50 scfh, well within the overall goal for the Department of Energy (DOE) program. Upon closer inspection, it was observed that more than 10% of datapoints contributing to the MAPE predictions were the result of low flow rate predictions and are beyond the sensitivity of instrument measurement as a result of normal operational variation and noise.

03 NATURAL GAS↗

Field Test Best Practices

This report can be used as a resource for advice on every stage of field research in residential buildings. It can be used as a reference document to find descriptions of specific types of common measurements and tricks of the trade, or as a primer on home field research providing a basic education on the subject. The report begins with descriptions of field experiment design and discusses advantages and disadvantages of different types of data acquisition systems. The bulk of the paper describes the common measurements needed in residential field work, the hardware options for making the measurements, and field notes on with tips, tricks, and cautions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Vibronic Coupling and Exciton Chirality: Electronic and Structural Rearrangement between Helical to Zero Momentum Molecular Exciton States

Helical porphyrin aggregates are attractive macromolecular nanostructures for biomimetic light-harvesting and energy transfer in solar energy technology due to their large light absorbing cross sections and promising energy conservation benefits from chiral-induced spin selectivity. However, with these soft materials, it is imperative that we understand how the nuclear degrees of freedom impact the excitonic energy landscape and dynamics, particularly pertaining to how it influences the chiral angular momentum of the excitons. To this end, we have measured time-resolved depolarization ratios using femtosecond stimulated Raman spectroscopy to uncover the vibronic coupling guided by molecular vibrations between excitons of different angular momentum in helical tetra(sulfonatophenyl)porphyrin aggregates. We find that while transient absorption anisotropy reveals rapid (1 ps lifetime) exciton rotation from helical to achiral states in the Q-band, time-resolved vibrational depolarization ratios evolve on remarkably faster time scales (<500 fs lifetime) for the totally symmetric 1530 cm –1 vibration and the nontotally symmetric 1540 cm –1 vibration. The time-resolved depolarization ratios of the 1540 cm –1 vibration, in particular, show strong evidence of vibronic coupling and nonadiabatic exciton behavior that mediates the nonradiative transition between chiral and achiral excitons. Furthermore, our study shows that for rational design of helical molecular aggregates for exciton transport, the vibronic coupling between excitons of different angular momenta driven by molecular vibrations must be considered especially in the case where chiral-induced spin selectivity is desired.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Commercial Zero Code Plug-In: Zero Energy and Operational Emissions Overlay for Model Energy Codes (Technical Brief)

Model energy codes (MEC) describe requirements needed to demonstrate building energy performance compliance. They can be readily adopted by states and local jurisdictions to support desirable energy efficiency investment in new buildings and major renovations. This report provides commercial building energy code language as an overlay to current MEC, which is recognized by the U.S. DOE as ASHRAE Standard 90.1 2022. The code language provides a performance-based compliance path for achieving net zero energy or net zero operational energy emissions buildings with MEC. The path requires meeting two compliance metric target values: 1) a required minimum level of efficiency and 2) a measure of zero energy or emissions. The supporting documentation illustrates the magnitude of needed efficiency improvement and the additional offsets to be achieved from renewable energy sources.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Scenario Documentation: Reduced Thermostat Setbacks for Heat Pumps

This report provides documentation of a measure for the End Use Savings Shapes project, which consists of analysis of different energy efficiency and renewable energy measures on the commercial building stock, using NREL's ComStock tool. The measure consists of a reduction in thermostat setbacks for air-source heat pump RTUs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shedding in Large Offices

This documentation focuses on a single End-Use Savings Shape measure - thermostat control for load shedding. The thermostat control for load shedding measure applies heating and cooling temperature setpoint offsets for reducing the heating and cooling load during peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the peak window, and then adjusts the thermostat cooling and/or heating setpoints by an offset value from original schedules during the peak window to reduce the HVAC or whole building daily peak load. The measure is flexible and allows users to adjust the heating and cooling offset values respectively, but for this study, the adjustment for heating and cooling setpoints are set to -2 degrees Celsius and +2 degrees Celsius by default. The measure provides options of adding rebound control period (default 2 hours) after peak windows for the setpoints to be ramped back to default values, to prevent the system from generating higher peak demand with step changes of setpoints in post-peak periods . This measure is applicable t o large offices equipped with electric HVAC system (either electric cooling only or both electric heating and cooling), which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shedding measure demonstrates 2-5% daily peak demand reduction and 0.068% total site energy savings (3 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Knoxville's Community Development Corporation

Develop and field validate integrated retrofit solutions (overclad composite panels, easy-to-install panel connections, and a cost-effective approach to gather measurements of existing facades) that are applicable to residential and mid-size commercial buildings, although components of the retrofit package can be implemented in other buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Validation of a Simulation Testbed for the Intelligent Building Agents Laboratory (IBAL) Using TRNSYS

This paper documents the development and validation of a dynamic primary cooling and thermal storage system simulation testbed. The system simulation testbed, sIBAL, is based on the Intelligent Building Agents Laboratory (IBAL) at the National Institute of Standards and Technology (NIST), which is a research infrastructure and testbed for the development, evaluation, and demonstration of intelligent control algorithms. The sIBAL testbed developed in this project will serve as a virtual twin of the real facility for future control algorithm development. The details of the methodologies used to develop and validate the simulation testbed, which replicates the dynamic behaviors of the primary cooling and ice storage system in the IBAL facility, are presented. The simulation testbed was developed in TRNSYS using built-in component models and MATLAB functions to replicate the two water-cooled chillers, a thermal storage tank, pumps, valves and other components for four different operation modes. Experiments on IBAL components were designed and executed to generate experimental data for model development and verification of the simulation platform. The validation of the simulation results was carried out in two phases: 1) independent component simulations for the chillers and thermal storage tank, and 2) a combined testbed simulation of the entire hydronic system. Comparison of simulation results to the experimental data obtained from the IBAL facility showed errors within 1 °C for the temperatures outputs of both the chiller and the thermal storage model. The error is within an acceptable range for further intelligent control algorithms development. The findings from the study are summarized and presented along with areas where additional research is needed. In addition, data filtering procedures and model refinement measures utilized to improve the accuracy and accelerate the computation time of the simulation are presented.

cooling systems↗

Theory of ignition and burn propagation in inertial fusion implosions

A detailed analytic model is presented here to investigate the physics of burn propagation in inertially confined plasmas. The onset of ignition and burn propagation occurs when alpha heating of the hot spot causes rapid ablation of shell mass into the hot spot. This allows large energy gains to be achieved since most of the fuel mass is located in the shell. Here, we first present a comprehensive review of previous analytic models that have been used to describe the physics of hot-spot evolution and ignition; we then show that a proper description of a propagating burn wave requires a comprehensive model of hot spot and shell evolution that includes proper mass conservation in the shell, fusion reactivity, and fuel depletion. The analytic theory is in good agreement with detailed radiation-hydrodynamic simulations that predict the onset of burn propagation as occurring when the yield enhancement caused by alpha heating is between 15- and 25-fold, $f_α$ ~ 1.4, where $f_α$ = alpha energy deposited/hot-spot energy at bang time, and the hot-spot burnup fraction is approximately 2%. We show that the definition of ignition is not sensitive to the alpha-particle stopping power nor asymmetries provided that the absorbed fraction of alpha particles $θ_α$ is correctly accounted for. Finally, we use the results of 2-D simulations to show that even when $θ_α$ is small and unknown (as is true in hot spots with mid modes that have significant leakage of alpha particles into the surrounding cold bubbles), one can still relate the experimentally measureable parameter $\chi^{53}_α$ to the yield amplification and the burning-plasma parameter $Q^{\text{hs}}_α$ = alpha energy deposited/total input work delivered to the hot spot

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integration of a Smart Outlet-Based Plug Load Management System with a Building Automation System

The growth of and reliance on renewable energy necessitate a multi-pronged approach to achieve grid reliability and economics. As they represent a notable portion of U.S. energy consumption, commercial buildings must play an active role in this effort. Conserving energy and responding to grid conditions through demand flexibility can be achieved through the integration of major building systems. Integration of plug and process loads with lighting and heating, ventilation, and air conditioning systems maximizes the effectiveness of integrated building energy management. In this research, we demonstrate the integration of smart outlets into a building automation system. We cover the installation process as well as the architecture required for smart outlets to communicate data to the building automation system and to receive commands back. After recording power measurements for one week as a baseline, we configured the building automation system to turn the smart outlets on and off according to a set schedule. This resulted in energy savings of 66% during 1 week on 25 plug loads. This work demonstrates that grid-interactive efficient buildings are achievable through building system integration.

building automation system↗

Conserving Land–Atmosphere Synthesis Suite (CLASS)

Accurate estimates of terrestrial water and energy cycle components are needed to better understand climate processes and improve models’ ability to simulate future change. Various observational estimates are available for the individual budget terms; however, these typically show inconsistencies when combined in a budget. In this work, a Conserving Land–Atmosphere Synthesis Suite (CLASS) of estimates of simultaneously balanced surface water and energy budget components is developed. Individual CLASS variable datasets, where possible, 1) combine a range of existing variable product estimates, and hence overcome the limitations of estimates from a single source; 2) are observationally constrained with in situ measurements; 3) have uncertainty estimates that are consistent with their agreement with in situ observations; and 4) are consistent with each other by being able to solve the water and energy budgets simultaneously. First, available datasets of a budget variable are merged by implementing a weighting method that accounts both for the ability of datasets to match in situ measurements and the error covariance between datasets. Then, the budget terms are adjusted by applying an objective variational data assimilation technique (DAT) that enforces the simultaneous closure of the surface water and energy budgets linked through the equivalence of evapotranspiration and latent heat. Comparing component estimates before and after applying the DAT against in situ measurements of energy fluxes and streamflow showed that modified estimates agree better with in situ observations across various metrics, but also revealed some inconsistencies between water budget terms in June over the higher latitudes.

54 ENVIRONMENTAL SCIENCES↗