Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Ambient and Initial Temperature Effects on Energy Consumption Rate Modeled in FASTSim

Ambient and initial temperatures significantly impact the energy consumption rate (ECR) of battery electric vehicles (BEVs) due to auxiliary loads and the temperature dependence of battery efficiency. This study introduces a streamlined, physics-based thermal modeling approach within the FASTSim tool that bridges the gap between oversimplified constant-load models and computationally expensive high-fidelity simulations. By employing a lumped thermal mass framework, the model captures fundamental energy balances and critical non-linear energy penalties while maintaining the computational efficiency required for expansive sensitivity studies. The simulations evaluated a compact BEV hatchback with a resistive heater over city (UDDS) and highway (HWFET) test cycles. Compared to a 22 degrees Celsius initial and ambient temperature baseline, a -7 degrees Celsius initial/ambient temperature resulted in a 221% increase in the ECR for the city cycle and a 100% increase for the highway cycle. Conversely, a 45 degrees Celsius initial / 40 degrees Celsius ambient temperature resulted in a 40% increase for UDDS and an 18% increase for HWFET. These results demonstrate that while cold conditions impose the most severe energy penalties due to resistive heating, the impact is consistently more pronounced in city driving where auxiliary loads represent a larger proportion of total energy. This lightweight yet robust framework enables researchers to rapidly quantify BEV thermal sensitivity across diverse climates without the need for high-overhead simulation environments.

33 ADVANCED PROPULSION SYSTEMS↗

Techno-economic feasibility of borehole thermal energy storage system connected to geothermal heat pumps for seasonal heating load of two buildings in Fairbanks, Alaska

Borehole thermal energy storage (BTES) is an effective solution for managing imbalanced heating and cooling loads in cold regions. This study evaluated the long-term feasibility of a BTES system in the Fairbanks area, Alaska, through building energy modeling, resource characterization, and numerical modeling. The system was designed to store waste heat from a nearby coal power plant during summer and provide thermal energy during winter to geothermal heat pumps supplying heating loads in two buildings. Heating load profiles were modeled for the buildings using EnergyPlus, and the results indicated the annual heating load was 5.6 times greater than the cooling load. 40 borehole heat exchangers were pre-designed approximately 100 m away from the two buildings in terms of land availability and regulatorily optimized depth. The 20-year performance of the designed BTES system under two operational scenarios—one with a 5-year preheating period and one without—was numerically modeled using subsurface temperature and properties characterized through the literature review and thermal response tests. Both scenarios demonstrated that the BTES has the capacity to fully cover the heating loads in the two buildings throughout the 20-year lifetime. Production temperatures at central wells were 33 % higher on average than at outer wells in both scenarios. The 5-year preheating period increased subsurface and extraction temperatures, and correspondingly annual average and total thermal energy production was higher for 8 years than in the scenario without the preheating period. These results highlight the long-term reliability and sustainability of the BTES system in meeting heating demands over its lifetime, with the preheating period offering potential performance improvements. Implementing the BTES system in cold regions with high heating demand, such as Fairbanks, Alaska, could provide a long-term, sustainable energy solution for managing imbalanced heating and cooling loads.

15 GEOTHERMAL ENERGY↗

Microstructural, Magnetic Anisotropy, and Magnetic Domain Structure Correlations in Epitaxial FePd Thin Films with Perpendicular Magnetic Anisotropy

L1(sub 0)-ordered FePd epitaxial thin films were prepared using dc magnetron sputter deposition on MgO (001) substrates. The films were grown with varying thickness and degree of chemical order to investigate the interplay between the microstructure, magnetic anisotropy, and magnetic domain structure. The experimentally measured domain size/period and magnetic anisotropy in this high perpendicular anisotropy system were found to be correlated following the analytical energy model proposed by Kooy and Enz that considers a delicate balance between the domain wall energy and the demagnetizing stray field energy.

Skuza, J. R.↗

Benefits Of Automated Construction And Energy Efficiency Measures In Modular Homes

This article builds on and adds to a Buildings XV publication that introduced the Transformative Efficiency and Automation in Modular Homes (TEAMH) project. The TEAMH project sought to develop a scalable solution for producing modular homes with 20-50% energy savings and similar cost relative to site-fabricated single-family home construction. A key aspect of the project was assessing the potential for labor cost reductions through automation-assisted construction using light gauge steel (LGS). To quantify the advantages of this approach, side-by-side comparisons were made between traditional wood-framed construction and automation-assisted LGS construction. This demonstration involved constructing one wood-framed wall and several LGS test walls, accompanied by a time-and-motion study. The results indicated that automation assistance could decrease construction time and associated labor costs by as much as 46%. High-performance envelope technologies for exterior insulation and air sealing were evaluated to compare modular homes with site-built homes that meet the International Energy Conservation Code (IECC). A key technology considered was vacuum insulation panels (VIPs) with fiberglass cores. Guarded hot box testing of multiple full-scale wall assemblies containing different combinations of exterior continuous insulation systems containing phenolic foam and VIPs. Testing on various full-scale wall assemblies revealed that, with LGS construction, cavity insulation had minimal impact on exterior wall performance. Omitting cavity insulation can reduce labor and material costs while streamlining manufacturing, as its installation is labor-intensive and not easily automated due to the need for precise placement around wiring and other internal components. Guarded hot box tests of multiple LGS test walls with foam and VIP-based exterior insulation systems achieved R-values of up to 31 hr-ft2-°F/Btu. Finally, building energy modeling of multiple modular home designs indicated that the upgraded envelope assemblies can yield heating energy savings of up to 50% and cooling energy savings of up to 30% compared to IECC 2018 standards.

Shrestha, Som [ORNL] (ORCID:0000000183993797)↗

Blur Clarified: A review and Synthesis of Blur Discrimination

Blur is an important attribute of human spatial vision, and sensitivity to blur has been the subject of considerable experimental research and theoretical modeling. Often these models have invoked specialized concepts or mechanisms, such as intrinsic blur, multiple channels, or blur estimation units. In this paper we review the several experimental studies of blur discrimination and find they are in broad empirical agreement. But contrary to previous modeling efforts, we find that the essential features of blur discrimination are fully accounted for by a visible contrast energy model (ViCE), in which two spatial patterns are distinguished when the integrated difference between their masked local contrast energy responses reaches a threshold value.

Watson, Andrew B.↗

Structural uncertainty assessment for low-Mach wall-resolved large-eddy simulations: Plane Channel and Periodic Hill Use Cases

A structural uncertainty assessment is provided for a set of wall-resolved large-eddy simulations (WRLES) using a turbulent channel flow (𝑅𝑒 𝜏 395) and a periodic hill in the turbulent regime (𝑅𝑒 𝑏 2800) validation suite. The standard one-equation subgrid scale turbulent kinetic energy model (𝑘 𝑠𝑔𝑠 ) using both a static and dynamic coefficient approach along with Wall Adapting Local Eddy Viscosity (WALE) are exercised. The 𝑘 𝑠𝑔𝑠 model activated in this study also allows for a correction that supports theoretical turbulent viscosity and total kinetic energy scaling (cubit and quadratic, respectively) in the near-wall regime. Channel and hill results showcase very good agreement between prediction and simulation for the WALE and the dynamic coefficient 𝑘 𝑠𝑔𝑠 model. The study also demonstrates that near-wall damping improves predictivity for the static coefficient 𝑘 𝑠𝑔𝑠 model, while proving an unnecessary additional contribution for the dynamic coefficient 𝑘 𝑠𝑔𝑠 model as near-wall scaling is naturally captured. Overall conclusions are that this suite of WRLES models are well suited for production usage in the Sierra-based low-Mach codes.

97 MATHEMATICS AND COMPUTING↗

Hybrid-Electric Aero-Propulsion Controls Testbed Results with Energy Storage

Electrified aircraft propulsion (EAP) research is a priority of the National Aeronautics and Space Administration (NASA) for its potential to increase propulsion system efficiency, performance, and operability at the subsystem and vehicle levels while decreasing emissions. These EAP systems demand more advanced control algorithms due to increased complexity. NASA has developed a reconfigurable, hardware-in-the-loop rig to verify control algorithm performance using a sub-scale electro-mechanical system. A novel capability of this rig is the ability to test full scale EAP control algorithms on a sub-scale representation of the electro-mechanical system without turbomachinery/rotors. A novel feature is the use of a physical energy storage device within the electro-mechanical system. A dual spool, parallel hybrid-electric turbofan architecture and energy management control system is tested with the goal of verifying the ability to obtain turbomachinery model operability benefits while controlling sub-scale electro-mechanical hardware. Pre-test predictions of the turbofan model, control, and rig performance were obtained through simulation using a software model of the rig. Theoretical results showing the true performance of the turbofan model were obtained through a software simulation using full-scale mechanical shaft models. The paper compares theoretical, predicted, and actual test results from the turbofan model, energy management control and rig perspectives. The results show that the presence of sub-scale electro-mechanical hardware did not inhibit the energy management algorithm from achieving turbomachinery operability benefits.

hybrid↗

Hybrid-Electric Aero-Propulsion Controls Testbed Results with Energy Storage

Electrified aircraft propulsion (EAP) research is a priority of the National Aeronautics and Space Administration (NASA) for its potential to increase propulsion system efficiency, performance, and operability at the subsystem and vehicle levels while decreasing emissions. These EAP systems demand more advanced control algorithms due to increased complexity. NASA has developed a reconfigurable, hardware-in-the-loop rig to verify control algorithm performance using a sub-scale electro-mechanical system. A novel capability of this rig is the ability to test full scale EAP control algorithms on a sub-scale representation of the electro-mechanical system without turbomachinery/rotors. A novel feature is the use of a physical energy storage device within the electro-mechanical system. A dual spool, parallel hybrid-electric turbofan architecture and energy management control system is tested with the goal of verifying the ability to obtain turbomachinery model operability benefits while controlling sub-scale electro-mechanical hardware. Pre-test predictions of the turbofan model, control, and rig performance were obtained through simulation using a software model of the rig. Theoretical results showing the true performance of the turbofan model were obtained through a software simulation using full-scale mechanical shaft models. The paper compares theoretical, predicted, and actual test results from the turbofan model, energy management control and rig perspectives. The results show that the presence of sub-scale electro-mechanical hardware did not inhibit the energy management algorithm from achieving turbomachinery operability benefits.

hybrid↗

Heating Ventilation Air-Conditioning (HVAC) System Analysis and Optimization for Revit with the OpenStudio Analytical Framework (CRADA Final Report)

This project proposes to integrate the NREL-developed OpenStudio (OS) and its accompanying Analytical Framework (OSAF) into Autodesk’s (ADSK’s) market leading suite of building information modeling (BIM) tools. As a result, BIM users will gain access to advanced (but user-friendly) building energy modeling (BEM), calibration, and design optimization capabilities. Following integration, the BIM software will automatically generate a consistent OS-based BEM model, allowing users to develop projects in an integrated manner, moving back and forth between architectural and engineering perspectives without redundancy or data loss, saving time and effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

HZETRN Radiation Transport Validation Using Balloon-Based Experimental Data

The deterministic radiation transport code HZETRN (High charge (Z) and Energy TRaNsport) was developed by NASA to study the effects of cosmic radiation on astronauts and instrumentation shielded by various materials. This work presents an analysis of computed differential flux from HZETRN compared with measurement data from three balloon-based experiments over a range of atmospheric depths, particle types, and energies. Model uncertainties were quantified using an interval-based validation metric that takes into account measurement uncertainty both in the flux and the energy at which it was measured. Average uncertainty metrics were computed for the entire dataset as well as subsets of the measurements (by experiment, particle type, energy, etc.) to reveal any specific trends of systematic over- or under-prediction by HZETRN. The distribution of individual model uncertainties was also investigated to study the range and dispersion of errors beyond just single scalar and interval metrics. The differential fluxes from HZETRN were generally well-correlated with balloon-based measurements; the median relative model difference across the entire dataset was determined to be 30%. The distribution of model uncertainties, however, revealed that the range of errors was relatively broad, with approximately 30% of the uncertainties exceeding ± 40%. The distribution also indicated that HZETRN systematically under-predicts the measurement dataset as a whole, with approximately 80% of the relative uncertainties having negative values. Instances of systematic bias for subsets of the data were also observed, including a significant underestimation of alpha particles and protons for energies below 2.5 GeV/u. Muons were found to be systematically over-predicted at atmospheric depths deeper than 50 g/cm(sup 2) but under-predicted for shallower depths. Furthermore, a systematic under-prediction of alpha particles and protons was observed below the geomagnetic cutoff, suggesting that improvements to the light ion production cross sections in HZETRN should be investigated.

James E Warner↗

Solar Ion Processing of Itokawa Grains: Reconciling Model Predictions with Sample Observations

Analytical TEM observations of Itokawa grains reported to date show complex solar wind ion processing effects in the outer 30-100 nm of pyroxene and olivine grains. The effects include loss of long-range structural order, formation of isolated interval cavities or "bubbles", and other nanoscale compositional/microstructural variations. None of the effects so far described have, however, included complete ion-induced amorphization. To link the array of observed relationships to grain surface exposure times, we have adapted our previous numerical model for progressive solar ion processing effects in lunar regolith grains to the Itokawa samples. The model uses SRIM ion collision damage and implantation calculations within a framework of a constant-deposited-energy model for amorphization. Inputs include experimentally-measured amorphization fluences, a Pi steradian variable ion incidence geometry required for a rotating asteroid, and a numerical flux-versus-velocity solar wind spectrum.

Christoffersen, Roy↗

Resilient Communities, Maryland (RCM): A Framework for Community-Driven Energy Resilience (Final Technical Report)

The Resilient Communities, Maryland (RCM) project integrates community-based participatory research (CBPR) approaches into energy resilience planning. The combination of qualitative, community-driven data and quantitative utility data improves both the effectiveness and efficiency of assessing the impacts of disruptions to energy infrastructure. Centered around a metric of critical services access, RCM created a repeatable framework for evaluating and modeling energy resilience in communities and promoted community engagement, resulting in more equitable stakeholder participation and improved decision-making processes for siting infrastructure to improve community energy resilience.

14 SOLAR ENERGY↗

A model for the CI (609 micron) emission of Orion

A numerical model energy balance and chemical equilibrium in the photodissociation regions at the edge of molecular clouds is presented. The model is used to calculate the emergent intensities of the following fine-structure lines: OI (at 63, 145 microns); CI (at 609, 370 microns); C II (at 158 microns); and the low-lying rotational transitions of CO. It is shown that column densities in the range 2 x 10 to the 17th to 2 x 10 to the 18th per sq cm can be obtained for the C(+)/C/CO transition region at the edges of molecular clouds. The difference in the column densities is attributed to changes in the charge exchange reactions of C(+) with SiO and S, and to the process of carbon self-healing. It is found that the calculations are in good agreement with the observed conditions in the photodissociation regions behind Orion (1) C Ori, and near the surface of OMC 1.

Tielens, A. G. G. M.↗

Compressible homogeneous shear: Simulation and modeling

Compressibility effects were studied on turbulence by direct numerical simulation of homogeneous shear flow. A primary observation is that the growth of the turbulent kinetic energy decreases with increasing turbulent Mach number. The sinks provided by compressible dissipation and the pressure dilatation, along with reduced Reynolds shear stress, are shown to contribute to the reduced growth of kinetic energy. Models are proposed for these dilatational terms and verified by direct comparison with the simulations. The differences between the incompressible and compressible fields are brought out by the examination of spectra, statistical moments, and structure of the rate of strain tensor.

Sarkar, S.↗

Compressible homogeneous shear - Simulation and modeling

Compressibility effects were studied on turbulence by direct numerical simulation of homogeneous shear flow. A primary observation is that the growth of the turbulent kinetic energy decreases with increasing turbulent Mach number. The sinks provided by compressible dissipation and the pressure dilatation, along with reduced Reynolds shear stress, are shown to contribute to the reduced growth of kinetic energy. Models are proposed for these dilatational terms and verified by direct comparison with the simulations. The differences between the incompressible and compressible fields are brought out by the examination of spectra, statistical moments, and structure of the rate of strain tensor.

Sarkar, S.↗

High-Resolution WRF-Based Downscaling of Earth System Model Projections for Energy Applications across CONUS

Evaluating energy resources under future scenarios requires meteorological information that adequately resolves regional-scale variability and is suitable for regional energy system studies. Although Earth system model (ESM) outputs provide essential large-scale context, their coarse resolution and inherent biases limit direct use in energy system applications. This work presents a high-resolution dynamical downscaling framework using the Weather Research and Forecasting (WRF) model to generate energy-relevant regional fields for future scenarios over the contiguous United States (CONUS). The framework first identifies an optimal WRF configuration through sensitivity experiments, then evaluates raw and bias-corrected ESM initial and boundary conditions, with soil moisture and soil temperature bias correction implemented as an integral component of the bias-corrected ESM atmospheric forcing prior to WRF dynamical downscaling to improve land-atmosphere interactions. Simulations performed at 4-km resolution show that uncorrected ESM forcing leads to systematically dry and cold soil states, which propagate into elevated near-surface air temperature and solar irradiance biases, particularly during summer for the period 2000-2014. Incorporating bias-corrected atmospheric forcing together with soil state bias correction substantially reduces these errors and improves the representation of surface energy processes in WRF simulations. The results highlight the importance of bias-aware initialization strategies in high-resolution dynamical downscaling for future energy system analysis and planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗