Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Performance Assessment of a Photonic Radiative Cooling System for Office Buildings

Spectrally selective materials show high technical potential for use as radiative cooling heat exchangers for buildings. Recent work by Stanford University has applied a photonic approach to tailor the optical properties of a coating material. In a prototype test, a radiative cooler based on that photonic material has demonstrated the ability to maintain radiator surfaces at below-ambient temperatures in the presence of intense, direct sunlight. This paper presents the simulation and parametric analysis of photonic radiative cooling system that integrates the use of the photonic radiative cooler and radiant floor cooling via the whole energy simulation program EnergyPlus. The simulation was made for a medium office building with three floors and a total floor area of 5,000 m2. Three key design parameters including the storage tank size, the radiator area, and the number of floors are expected to have a large impact on system performance were investigated in this paper. The results show that the percentage of cooling electricity savings from the photonic radiative cooling system relative to a reference variable-air-volume system has a linear relationship with the radiator area, and a quadratic correlation with both tank size and the number of floors. The findings from this parametric analysis are valuable to understand how component sizing affects system performance.

Wang, Weimin↗

In-Situ Statistical Analysis of Autotune Simulation Data using Graphical Processing Units

Developing accurate building energy simulation models to assist energy efficiency at speed and scale is one of the research goals of the Whole-Building and Community Integration group, which is a part of Building Technologies Research and Integration Center (BTRIC) at Oak Ridge National Laboratory (ORNL). The aim of the Autotune project is to speed up the automated calibration of building energy models to match measured utility or sensor data. The workflow of this project takes input parameters and runs EnergyPlus simulations on Oak Ridge Leadership Computing Facility’s (OLCF) computing resources such as Titan, the world’s second fastest supercomputer. Multiple simulations run in parallel on nodes having 16 processors each and a Graphics Processing Unit (GPU). Each node produces a 5.7 GB output file comprising 256 files from 64 simulations. Four types of output data covering monthly, daily, hourly, and 15- minute time steps for each annual simulation is produced. A total of 270TB+ of data has been produced. In this project, the simulation data is statistically analyzed in-situ using GPUs while annual simulations are being computed on the traditional processors. Titan, with its recent addition of 18,688 Compute Unified Device Architecture (CUDA) capable NVIDIA GPUs, has greatly extended its capability for massively parallel data processing. CUDA is used along with C/MPI to calculate statistical metrics such as sum, mean, variance, and standard deviation leveraging GPU acceleration. The workflow developed in this project produces statistical summaries of the data which reduces by multiple orders of magnitude the time and amount of data that needs to be stored. These statistical capabilities are anticipated to be useful for sensitivity analysis of EnergyPlus simulations

accelerators↗

Improving Residential Building Simulations Through Large-Scale Empirical Validation

Residential building energy simulations are increasingly used for energy-efficient building design, codes and standards analysis, home certifications and ratings, utility programs, and technology assessments. Various software tools exist to perform residential building simulations, and these tools often use different models, inputs, and assumptions. This leads to inconsistencies that can undermine confidence in the predicted results. Validation of these tools can increase confidence by ensuring their accuracy and consistency. One way to validate simulation tools is through empirical testing, which compares predicted energy usage to measured utility billing data. This paper describes the process of data collection, data standardization, and empirical validation, and illustrates its use with our residential EnergyPlus (R)-based software. The data and process can be extended to other simulation tools and contribute to improving residential building simulations more broadly.

empirical validation↗

Potential impact of work from home jobs on residential energy bills: A case study in phoenix, AZ, USA

Nearly one-third of U.S. households face challenges paying energy bills. During the day, many residents have routine access to cooled environments provided by others—employers, shopping centers, and other public buildings. The COVID-19 pandemic, however, has significantly shifted the cost burden of air conditioning in hot cities. Specifically, during the pandemic, many companies either laid off employees or put them in work-from-home (WFH) assignments. Large tech companies are already promoting WFH as a long-term option for their employees, even after the pandemic. This change in the nature of the workforce might reduce daily travel expenses for workers, but could also significantly increase residential energy bills, particularly during summer in very hot climates. Here, this study uses building energy simulations to quantify the potential residential energy bill penalties resulting from WFH for typical residences in Phoenix. Four building archetypes are used in this study to represent variations in building vintage, occupancy, and characteristics. The results show that, for some single-family residences in Phoenix, WFH can increase annual energy bills by more than $1100 (up to a 70% increase). The study also demonstrates that building performance enhancement retrofit measures have the potential to reduce this WFH energy bill penalty for the existing buildings substantially.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Performance of Awnings in Residential Buildings

Residential buildings consume approximately 20% of the total primary energy in the United States. More than 50% of this energy is spent in heating, cooling, and lighting these buildings. Solar heat gain is one of the largest and most variable sources of cooling load in these buildings, while it can also provide passive heating during the heating season. Shading devices can be used to control the amount of solar heat gain in buildings. Various studies have considered how different shading devices and their applications affect energy and occupant comfort in buildings. However, most of these studies were limited to planar shading devices such as roller shades, cellular shades, and blinds. Although some theoretical studies have been performed for awnings, the energy performance of awnings has rarely been studied via either energy simulation or field measurement. In this study, the authors evaluated the energy performance of typical operable awnings by using field data, aided by simulation. Awnings were installed on a real house, and measurements were performed to evaluate the thermal performance of the awning. The measured data were then used to develop a calibrated energy model and evaluate the awning’s energy performance. The annual simulation of the building model used showed that awnings left in the closed position from April to September can reduce annual HVAC energy consumption by 15% compared with a building without any shades. The validated model was used in US Department of Energy prototype buildings to evaluate awning energy performance in climate zones 1A through 4B via energy simulation. For these prototype buildings, energy savings of up to 1,034 kWh were achieved for a building with a conditioned floor area of 2,377 ft 2 .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Brookhaven Co-Hosts 2018 U.S. DOE CyberForce Competition

In December 2018, five college teams came to Brookhaven Lab to participate in the CyberForce Competition, an annual U.S. Department of Energy (DOE)-sponsored nationwide cyberdefense competition in which students defend a simulated energy infrastructure network from cyberattack. They competed against more than 50 teams hosted by six other national labs.

97 MATHEMATICS AND COMPUTING↗

Estimating Building Simulation Parameters via Bayesian Structure Learning

Many key building design policies are made using sophisticated computer simulations such as EnergyPlus (E+), the DOE flagship whole-building energy simulation engine. E+ and other sophisticated computer simulations have several major problems. The two main issues are 1) gaps between the simulation model and the actual structure, and 2) limitations of the modeling engine's capabilities. Currently, these problems are addressed by having an engineer manually calibrate simulation parameters to real world data or using algorithmic optimization methods to adjust the building parameters. However, some simulations engines, like E+, are computationally expensive, which makes repeatedly evaluating the simulation engine costly. This work explores addressing this issue by automatically discovering the simulation's internal input and output dependencies from 20 Gigabytes of E+ simulation data, future extensions will use 200 Terabytes of E+ simulation data. The model is validated by inferring building parameters for E+ simulations with ground truth building parameters. Our results indicate that the model accurately represents parameter means with some deviation from the means, but does not support inferring parameter values that exist on the distribution's tail.

Energy Modeling↗

A coupled fluid-mechanical workflow to simulate the directed energy deposition additive manufacturing process

Simulation of additive manufacturing processes can provide essential insight into material behavior, residual stress, and ultimately, the performance of additively manufactured parts. In this work, we describe a new simulation based workflow utilizing both solid mechanics and fluid mechanics based formulations within the finite element software package SIERRA (Sierra Solid Mechanics Team in Sierra/Solid Mechanics 4.52 User’s Guide SAND2019-2715. Technical report, Sandia National Laboratories, 2011) to enable integrated simulations of directed energy deposition (DED) additive manufacturing processes. In this methodology, a high-fidelity fluid mechanics based model of additive manufacturing is employed as the first step in a simulation workflow. This fluid model uses a level set field to track the location of the boundary between the solid material and background gas and precisely predicts temperatures and material deposition shapes from additive manufacturing process parameters. Next, the resulting deposition shape and temperature field from the fluid model are then mapped into a solid mechanics formulation to provide a more accurate surface topology for radiation and convection boundary conditions and a prescribed temperature field. Solid mechanics simulations are then conducted to predict the evolution of material stresses and microstructure within a part. By combining thermal history and deposition shape from fluid mechanics with residual stress and material property evolutions from solid mechanics, additional fidelity and precision are incorporated into additive manufacturing process simulations providing new insight into complex DED builds.

36 MATERIALS SCIENCE↗

Stochastic scheduling for commercial building cooling systems: considering uncertainty in zone temperature prediction

Here, this paper presents the first attempt to address the uncertainty in zone temperature prediction with stochastic optimization. The uncertain zone temperature is a process uncertainty and has not been considered in the existing stochastic optimization for building control. To fill this gap, we proposed a novel formulation of stochastic optimization to handle process uncertainty in building control. Specifically, we first examined the accuracy of a typical linear model for predicting zone temperature. We then formulated the scheduling of the building cooling system as a stochastic optimization problem over a 24-hour look-ahead period to minimize the electricity cost of the studied building cooling system. After that, we applied the proposed stochastic load scheduling (SLS) to a direct expansion (DX) cooling system that serves a medium office building. Through simulation with a detailed building energy simulation software, EnergyPlus, we evaluated the operational cost and the thermal comfort compared with a deterministic load scheduling. The operation cost of scheduling was found to vary with the level of zone temperature prediction uncertainty. The proposed SLS can mitigate the impacts of uncertain zone temperature predictions on both operational cost and thermal comfort. The evaluation results indicate that the proposed SLS works better when the uncertainty level is more significant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A method to generate heating and cooling schedules based on data from connected thermostats

Internet-connected thermostats are a promising new source of temperature and operational data in homes because they record inside temperatures, setpoints, and HVAC runtimes every five minutes. Over 20 million Internet-connected thermostats have already been installed in American homes. Data from about 20,000 connected thermostats were collected and organized by climate zone, number of occupants, floor area, and day type. A method was developed to create up to 40 representative temperature schedules which, together, can more accurately capture the diversity of heating and cooling behaviors. These results are suitable for input into schedules for building energy simulation models. This information enables more realistic simulations of American heating and cooling behavior, leading to more accurate estimates of energy consumption and savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

This study was conducted by the Pacific Northwest National Laboratory (PNNL) in support of the stretch energy code development led by the New York State Energy Research and Development Authority (NYSERDA). In 2017 NYSERDA developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code (hereinafter referred to as “NYStretch-Energy”). NYStretch-Energy is intended as a model energy code for statewide voluntary adoption that anticipates other code advancements culminating in the goal of a statewide Net Zero Energy Code by 2028. Since then, NYSERDA continues to develop the NYStretch-Energy Code 2018 edition. To support the effort, PNNL conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code (2018) in New York. The focus of this project is the 20% improvement over existing commercial model energy codes. A key requirement of the proposed stretch code is that it be ‘adoptable’ as an energy code, meaning that it must align with current code scope and limitations, and primarily impact building components that are currently regulated by local building departments. It is largely limited to prescriptive measures, which are what most building departments and design projects are most familiar with. This report describes a set of energy-efficiency measures (EEMs) that demonstrate 20% energy savings over ANSI/ASHRAE/IES Standard 90.1-2013 (ASHRAE 2013) across a broad range of commercial building types and all three climate zones in New York. In collaboration with New Building Institute, the EEMs were developed from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the on-going code development process. PNNL analyzed these measures using whole building energy models for selected prototype commercial buildings and multifamily buildings representing buildings in New York. Section 2 of this report describes the analysis methodology, including the building types and construction area weights update for this analysis, the baseline, and the method to conduct the energy saving analysis. Section 3 provides detailed specifications of the EEMs and bundles. Section 4 summarizes the results of individual EEMs and EEM bundles by building type, energy end-use and climate zone. Appendix A documents detailed descriptions of the selected prototype buildings. Appendix B provides energy end-use breakdown results by building type for both the baseline code and stretch code in all climate zones.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Final Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

This study was conducted by the Pacific Northwest National Laboratory (PNNL) in support of the stretch energy code development led by the New York State Energy Research and Development Authority (NYSERDA). In 2017 NYSERDA developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code (hereinafter referred to as “NYStretch-Energy”). NYStretch-Energy is intended as a model energy code for statewide voluntary adoption that anticipates other code advancements culminating in the goal of a statewide Net Zero Energy Code by 2028. Since then, NYSERDA continues to develop the NYStretch-Energy Code 2018 edition (NYSERDA 2018). To support the effort, PNNL conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code 2018 in New York. The focus of this project is to significantly improve the energy efficiency over existing commercial model energy codes. A key requirement of the proposed stretch code is that it be ‘adoptable’ as an energy code, meaning that it must align with current code scope and limitations, and primarily impact building components that are currently regulated by local building departments. It is largely limited to prescriptive measures, which are what most building departments and design projects are most familiar with. This report describes a set of energy-efficiency measures (EEMs) that demonstrate significant energy savings over ANSI/ASHRAE/IES Standard 90.1-2013 (ASHRAE 2013) across a broad range of commercial building types and all three climate zones in New York. In collaboration with New Building Institute, the EEMs were developed from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the on-going code development process. PNNL analyzed these measures using whole building energy models for selected prototype commercial buildings and multifamily buildings representing buildings in New York.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗