Search NASA⌕ Search

SEARCH · Search NASA

Results for “Engineering - Other instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

ExoMars Mars Organic Molecule Analyzer (MOMA) Laser Desorption/Ionization Mass Spectrometry (LDI-MS) Analysis of Phototrophic Communities from a Silica-Depositing Hot Spring in Yellowstone National Park, USA

The Mars Organic Molecule Analyzer (MOMA) is a key scientific instrument on the ExoMars Rover mission. MOMA is designed to detect and characterize organic compounds, over a wide range of volatility and molecular weight, in samples obtained from up to two meters below the martian surface. Thorough analog sample studies are required to best prepare to interpret MOMA data collected on Mars. We present here the MOMA characterization of Mars analog samples collected from an alkaline silica depositing hot spring in Yellowstone National Park, WY, USA. These samples contain microbial streamer communities composed primarily of oxygenic and anoxygenic phototrophs. Additionally, in a study focused on detection of key classes of nonvolatile organics, samples of microbial streamers and their total lipid extract (TLE) have been measured on a MOMA Engineering Test Unit (ETU) instrument using its laser desorption/ionization mass spectrometry (LDI-MS) mode. MOMA LDI-MS detected a variety of lipids and pigments in the TLE sample. Species such as chlorophyll a were also detected from the streamer sample with the help of mass isolation. The results add to the LDI-MS sample characterization database, as well as demonstrate the benefit of using mass isolation on the MOMA instrument to reveal the presence of complex organics, and potential biomarkers, preserved in a natural sample, providing guidance to the in situ analysis of surface samples during Mars operations.

59 BASIC BIOLOGICAL SCIENCES↗

Non-Nuclear Test Facility Development to Support Verification and Validation Needs

This study focuses on developing a non-nuclear test facility to help meet the verification and validation (V&V) requirements of a water-cooled small modular reactor (SMR) system. The scaling analysis necessary for reactor system experimentation and assessment model V&V considers various reactor system accident scenarios such as main steam line break (MSLB), steam generator tube rupture (SGTR), and containment condensation and heat transfer. The goal is to identify key physics based phenomena of interest (POI), specific figures of merit (FOMs), and the state of knowledge (SOK) by employing phenomena identification and ranking table (PIRT) studies. Important physics phenomena such as heat transfer, fluid dynamics, structural integrity, and material selection must be addressed when scaling a thermal-hydraulics system. Alongside these considerations, modifications to the facility may be needed to align the scaled system with the available footprint (height and space) of the facility. These modifications may include infrastructure upgrades, changes to the piping layout, implementation of safety measures, and installation of new instrumentation and control systems. The test facility aims to provide a scaled-down version of prototypic facilities for comprehensive V&V activities by overcoming these challenges and making the necessary modifications. This approach minimizes scaling distortion, simulates prototypic plant conditions, and accurately models accident event progressions. Thus, the facility will be capable of adequately modeling a scaled SMR system to support the design, development and licensing needs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of a Radiation-Tolerant Front End Digitizer

High-radiation and high-temperature environments represent notoriously detrimental conditions for electronics. Yet sensors and instrumentation are critically important for the safe operation of nuclear reactors and for the validity of the scientific experiments conducted within them. Traditionally, sensors in such extreme environments operate with few active components, resulting in small signals (mV–V, nA–µA range) that must be transmitted through long cable runs before digitization by sensitive data acquisition systems located in clean, less-harsh environments. Long cables are prone to picking up noise through electromagnetic interference and distortion caused by their parasitic impedances, resulting in signal degradation. The Front End Digitizer (FREND) system described and demonstrated herein seeks to address these issues by enabling the placement of a radiation-resistant analog front end within reactor containment, or other high-radiation environments. FREND will enable early signal pre-amplification, digitization, and optical encoding within the high-radiation field to transmit sensor signals over an optical fiber to the non-nuclear environment of an instrument room. Early signal pre-amplification and digitization maintain signal integrity, whereas optical transmission renders the system blind to induced electromagnetic noise over the long cable runs. This report describes the FREND initial prototype, which can multiplex and optically encode data from up to four sensor inputs, though, in principle, this can be extended to any number of sensor inputs. The end result is an extremely flexible, high-fidelity system.

42 ENGINEERING↗

Fuel Property Effects of a Broad Range of Potential Biofuels on Mixing Control Compression Ignition Engine Performance and Emissions

Conventional diesel engines will continue to hold a vital role in the heavy- and medium-duty markets for the transportation of goods along with many other uses. The ability to offset traditional diesel fuels with low-net-carbon biofuels could have a significant impact on reducing the carbon footprint of these vehicles. A prior study screened several hundred candidate biofuel blendstocks based on required diesel blendstock properties and identified 12 as the most promising. Eight representative biofuel blendstocks were blended at a 30% volumetric concentration with EPA certification ultra-low-sulfur diesel (ULSD) and were investigated for emissions and fuel efficiency performance. This study used a single cylinder engine (based on the Ford 6.7L engine) using Conventional Diesel Combustion (CDC), also known as Mixing Control Compression Ignition (MCCI). The density, cetane number, distillation curve and sooting tendency (using the yield sooting index method) of the fuels were measured. Start of injection (SOI) timing and exhaust gas recirculation (EGR) sweeps were conducted at three separate speed-load operating points to examine fuel effects on the NOX/soot and NOX/efficiency trade-offs as well as to evaluate EGR tolerance. The results show that the biofuel blends all reduced NOX and soot emissions without penalty to engine efficiency, even improving efficiency for some of the blends at certain points, with one particular blend of polyoxymethylene ethers (POMEs) improving efficiency at all points while drastically reducing soot by 79%.

47 OTHER INSTRUMENTATION↗

Application-Specific Implementations: Self-Consistent Analysis, Uncertainty Estimation, Instrumentation Effects

When UF 6 is located on the bottom of a cylindrical container lying flat, the Hage-Cifarelli formalism can be used to reconstruct the multiplication of the UF 6 and the strength of the 234 U (a,n) source, from which the 235 U can be inferred. However, when the UF 6 sticks to the ends or to the sides of the container, the reconstruction is no longer predictive in terms of source strength. The same conclusions were reached, whether one uses 3 He tubes or scintillators to detect the neutrons. Feynman’s point theory underlying the reconstruction would need to be improved to address the differences in source strenghts observed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Progress Update on the In Situ Load Retention Aging Vessel

To improve upon our conventional thermally accelerated aging study methods which require periodic interruption of aging to perform load testing in an Instron machine, a new aging system is being developed to: (1) automate/facilitate data acquisition/analysis, (2) improve data quality, and (3) enable uninterrupted aging conditions (compression, temperature, atmosphere) which represents the service condition. In FY24, a thermal aging vessel instrumented with load cells was fabricated and tested. That unit demonstrated the primary function of the vessel: to continuously monitor the in situ load retention of up to three compressed polymer coupons undergoing thermally accelerated aging under nitrogen. A secondary objective, not realized in the unit due to inadequate sealing, was to enable a single initial nitrogen backfill (as opposed to a continuous purge) and gas sampling of the vessel headspace during thermal aging. Heating of the vessel was achieved using a custom heater jacket.

36 MATERIALS SCIENCE↗

Advanced Instrumentation Testbed (AIT) - antiNeutrino Experiment One (NEO) (Q1 FY2021)

In anticipation of the planned June 2021 design review, conceptual design, costing, and documentation efforts continued. The quarter was highlighted by the completion of three significant milestones: 1) 50% conceptual design and costing of the AIT facility, 2) bottom-up cost estimates for NEO, and 3) parametric NEO performance estimates (via the Big Trade Study). Because cost estimates exceed available funding levels, the project team started (late Dec 2020) a value engineering/pivot exercise to align costs with available funds. This exercise is anticipated to consume the project team for most of Q2. The end-result expectation (of the exercise) is a programmatically feasible and scientifically relevant AIT-NEO conceptual design that is aligned with available funds.

42 ENGINEERING↗

SECURED: Simulator-Enhanced Control and Understanding of Reactor systems for cyber-Event Defense

The study discusses a learning approach for analyzing cyber-events in reactor systems using integrated hardware and personal computer simulator models. Key points include the rise in cyber-attacks and their sophistication in industrial control systems (ICS), the necessity for awareness, understanding, resource allocation, and preparation to combat these threats, and the digital transformation of old and new nuclear plants, increasing their exposure to cyber threats. It highlights the cyber vulnerabilities of advanced reactor systems, which rely on digital instrumentation and control for operations and safety functions, making them susceptible to cyber-attacks. The approach involves demonstrating reactor system plant ICS cyber-attacks under various operational conditions utilizing tools like simulator models and hardware-based kits. A strategic solution approach tailored to critical infrastructure is emphasized, along with community engagement for public and government support, adopting effective learning approaches, and the preparation for anticipated future challenges. The presentation concludes with a call to action to address challenges, leverage opportunities, and advance through lesson learning in cybersecurity for nuclear energy systems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Data Analysis of X-ray Panels Used in X-ray CT Scientific Instruments

This report is a follow-up study on M. Skeate’s study on System Drift Detection for Health Monitoring (Skeate, 2023). The following report highlights analyses of the panel’s behavior with extended use. This includes effects of burn-in on the panel from over-use and bad pixels (defined in Methodology.) Using data-forward statistical analyses across a sequence of scans, and given that the other conditions present in the data can be replicated, this study show that overtime use of panels does not affect bad pixel count. Also, I present conclusive evidence of a direct relationship between the regions of the panel that are exposed to radiation and burn-in damage to that region overtime. Additionally, this study also highlights the effect of the duty cycle on the dark current change in the panel.

42 ENGINEERING↗

Anatomy of Protein Electrospray Ionization Mass Spectra by Superconducting Tunnel Junction Mass and Energy Spectrometry

Cryogenic superconducting tunnel junction (STJ) detectors have the advantage of single-particle sensitivity, high quantum efficiency, low noise, and the ability to detect the time and relative impact energy of deposited ions. This makes them attractive for use in mass spectrometry (MS) and as a form of energy spectrometry. STJ cryodetectors have been coupled to time-offlight (TOF) mass spectrometers equipped with a matrix-assisted laser desorption ionization (MALDI) source and to an electrospray ionization (ESI) TOF mass spectrometer. Here, a lab-made linear ion trap (LIT) mass spectrometer system was coupled to an ESI source and a 16-channel Nb-STJ array with improved readout electronics. The goal was to investigate fundamentals of ESI-generated protein ions by further exploiting the advantage of resolving these ions in a third dimension of the relative energy deposited into the STJs. The proteins equine cytochrome c, bovine carbonic anhydrase, bovine serum albumin, and murine immunoglobulin G were studied using this ESI-LIT-STJ-MS instrument. Multiply charged monomers, multimers, and fragments from metastable ions were resolved from monomer peaks by differences in ion deposition energy even when these ions have the same mass-to-charge ratio as the corresponding monomer. The determination of fragment mass from metastable decomposition is accomplished without knowing the charge state of the fragment. The average charge state of the multimers is reduced with each addition of a protein which is a direct reflection of the surface area available for charging. Multiply charged in-source fragments have also been observed and distinguished in the mass spectrum of carbonic anhydrase by using the differences in the energy deposited in the STJs.

42 ENGINEERING↗

Develop BNNT based cryopumps and detectors

Jefferson Lab Tasks to include period for performance of each task: 1. Design and fabricate initial test apparatus for cryosorber capacity comparison (month 0-3), 2. Test cryosorption capacity of BNNT materials (month 3-9) and alternate materials, 3. Design and fabricate cryopump modifications to accommodate BNNT material (month 9-15), 4. Provide suitable cryopump, electronics and vacuum instrumentation for the cryopump (month 12-18), and 5. Perform testing of BNNT modified cryopump at UHV-XHV pressure range (month 15-24). Modification 1: 6. Design initial detector test apparatus that incorporates BNNT material (months 0-1), 7. Provide photon detector as needed for tests (months 1-12), and 8. Perform tests (months 1-12). BNNT, LLC to 9. Provide Fibril BNNT™ for evaluation and cryopump (month 3-9), 10. Fabricate portions of modifications for cryopump (month 9-15), 11. Integrate Fibril BNNT™ into the cryopump (month 9-15), and 12. Perform regular vacuum testing of the cryopump (month 12-15). Modification 1: 13. Construct BNNT portions of detector test apparatus (months 0-2), 14. Provide BNNT material for detector tests (months 0-9), and 15. Assist in detector tests (months 1-12).

42 ENGINEERING↗

Noncontact Flow Rate Using Laser Ultrasonics

Several types of advanced nuclear reactors are cooled with high-temperature liquid metal or molten salt flows. There is a critical need to measure flow velocity in flow channels for test purposes, and eventually in operational reactors. In conventional ultrasonic flow sensors, ultrasonic waves traveling in both the upstream and downstream directions are generated and detected by transducers that must contact the flow channels. A shift in the frequency or transit time between the two ultrasonic waves is measured to determine flow velocity. We describe here an initial effort to apply that sensing concept when the contact transducers are replaced by laser-based generation and detection instrumentation. This noncontact sensing avoids many practical problems associated with contact transducers when implemented on flow channels at high temperature. Laser-based flow monitoring can also be applied to hot-process piping in the geothermal energy, chemical-processing and petroleum-refining industries. Our effort has included theoretical simulation of noncontact laser-based flow monitoring, indicating capability of measuring flow velocities relevant to reactor cooling. It also included a room-temperature experimental demonstration using water as the flow liquid, and indicating capability of measuring flow velocity at a responsivity roughly consistent with simulation predictions. Plans were made for an experimental demonstration at Oregon State University using liquid metal at 110 degrees C.

02 PETROLEUM↗

Draft Methodology for Cybersecurity Analysis for Adoption of Wireless Technology in Nuclear Power Plants

The report is delivered as DOE-NE Cybersecurity Program Milestone M2CT-22IN1104014-Industry cybersecurity guidance adoption status. The milestone is specifically to document the process and the status of the efforts towards developing guidance in support of industry’s adoption of wireless communication technologies. To transform the operation of nuclear power plants, including domestic light-water reactors, advanced reactors, microreactors, and fission battery, for grid and non-grid applications, secure and resilient wireless capabilities are required. In addition, to realize new operational concepts such as autonomous operation and remote monitoring, advanced sensor, and instrumentation, wireless technology is essential. However, industry implementation is low, and there is no technical basis for how to understand and address potential risks for wireless communications for critical plant functions. A methodology with a technical basis for implementing secure wireless communication is crucial. This wireless adoption methodology is intended to assist a licensee in identifying an appropriate technological approach for securing wireless communications in nuclear power plant. However, this methodology does not provide guidance for addressing wireless design criteria or for addressing all the cybersecurity commitments in licensees’ cybersecurity plans (CSPs) including addressing security impact analysis that a licensee must perform before an update to a Critical Digital Asset (CDA). This methodology guides a licensee through a process of evaluating a proposed wireless implementation and drafting a plant change notification for an example use case. The example is a generic/nonproprietary version of the first test case of the methodology, which, if successfully implemented, is part of the consideration for protecting other functions’ use of wireless in a cybersecure manner.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Accelerated Irradiation Testing and Post-Irradiation Characterization: U.S.-Based Capabilities for Advanced Nuclear Systems and Radioisotope Production

Irradiation experiments and post-irradiation examinations, together referred to as irradiation testing (IRT), are prerequisites for nuclear fuel and material qualification for the deployment of new and advanced reactors, as well as radioisotope production, thereby ensuring regulatory compliance. Qualified research and test reactors (RTRs) and testing facilities are essential to enable IRT to verify performance and safety under prototypical reactor conditions. In the past, qualification of new fuels or structural materials required about 20 years. Synergist strategies, advanced tools, and qualified methods are needed to greatly reduce this timeframe of IRT and radioisotope production. This study, termed accelerated-IRT, focuses on identifying gaps and leveraging U.S.-based RTRs and material testing capabilities, leveraging the preliminary evaluation and qualification of selected RTRs to provide a generic as well as specific-case solution paths forward, ensuring adherence to stringent regulatory standards. Furthermore, IRT and radioisotope production utilizing qualified RTRs necessarily includes modeling and simulation to support the design (i.e. neutronics, thermal, and structural aspects) and manufacturing of irradiation test specimens, vehicles, capsules, apparatuses, and flow loops. In addition, IRT can be improved by applying advanced manufacturing techniques and in-pile sensors and instrumentation, as discussed in this study.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Chapter 8: Searching for Life Beyond Earth

The search for life beyond Earth necessitates a rigorous and comprehensive examination of biosignatures, the types of observable imprints that life produces. These imprints and our ability to detect them with advanced instrumentation hold the key to our understanding of the presence and abundance of life in the universe. Biosignatures are the chemical or physical features associated with past or present life and may include the distribution of elements and molecules, alone or in combination, as well as changes in structural components or physical processes that would be distinct from an abiotic background. The scientific and technical strategies used to search for life on other planets include those that can be conducted in situ to planetary bodies and those that could be observed remotely. Here this chapter discusses numerous strategies that can be employed to look for biosignatures directly on other planetary bodies using robotic exploration including those that have been deployed to other planetary bodies, are currently being developed for flight, or will become a critical technology on future missions. Search strategies for remote observations using current and planned ground-based and space-based telescopes are also described. Evidence from spectral absorption, emission, or transmission features can be used to search for remote biosignatures and technosignatures. Improving our understanding of biosignatures, their production, transformation, and preservation on Earth can enhance our search efforts to detect life on other planets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser-based Adhesion Strength Measurements for Advanced Manufactured Sensor Adhesion Characterization

As part of the advanced manufacturing (AM) focus of the Nuclear Energy Enabling Technologies (NEET) Advanced Sensors and Instrumentation (ASI) Program, new in-house capabilities to fabricate and test novel active and passive in-pile sensors are being developed at the Idaho National Laboratory (INL). These advanced-manufactured sensors, such as peak temperature monitors and strain gauges, must be miniaturized and be able to provide real-time feedback, all while withstanding the coupled extremes of temperature and radiation typically observed in the environment of a nuclear test reactor. Fabricating durable and robust in-pile sensors with high fidelity requires a fundamental understanding of the optimal process parameters required in the AM technique, as well as the effect of deviations from optimal process parameters on the sensor-substrate adhesion and the ultimate robustness of the sensor. This report presents the use of a laser-based, non-contact approach for characterizing the adhesion of sensors manufactured using aerosol jet printing (AJP) that comprise of silver nanoparticle inks deposited and sintered on austenitic stainless steel (SS) 316L substrates. The effect of substrate surface roughness, surface energy, ink sintering time and sintering temperature on the printed sensor topography and the sensor-substrate adhesion has been systematically investigated. The sensor-substrate interfacial adhesion strength was determined from the critical laser pulse energy required to ablate/ detach the printed sensor from the substrate. Measurements of the sensor topography using optical profilometry revealed that post-deposition sintering at 400°C for 60 minutes resulted in a reduced sensor thickness, while plasma treating the substrate prior to printing yielded sensors with uniform thickness profiles transverse to the print direction. Sintering temperature and time were found to be the dominant parameters that affected sensor-substrate adhesion, followed by substrate surface roughness. The laser-based and locally-destructive approach for adhesion strength measurements shows promise in overcoming the challenges and limitations of current standardized peel tests and can be developed into a post-fabrication process control protocol for evaluating the durability of AM printed sensors in a high throughput fashion. Future studies will investigate the use of laser-induced spallation techniques as well as non-destructive laser ultrasonic methods for sensor-substrate adhesion characterization on sensors manufactured using AJP and other AM techniques such as plasma jet printing (PJP).

42 ENGINEERING↗

Robotic Assisted Non-Destructive Testing (NDT)

Mission Statement: Concrete wall characterization for structural integrity evaluation of H-Canyon exhaust tunnel using a remote controlled robotic arm with a NDT Concrete Instrument. Challenges: Rough and Curved Surfaces, Remote location. The UR5 is a collaborative robotic arm capable of: Payload: 11 lbs (5 kg), Reach: 33.5 in (850 mm), Footprint: 5.87 in (149 mm) diameter, Weight: 45.4 Ibs (20.6 kg). The force torque sensor reacts to a set value inputted by the user that can be utilized for sensitive products. This allows the UR5 to react to surfaces using the built-in function to search for a wall and orient itself normal to that plane. The Proceq Pundit 250 array is a nondestructive device that the user applies against a concrete wall and scans using ultrasonic transducers. The back wall and other defects can be show through the touchscreen. A fixture to hold the Proceq Pundit 250 array onto the UR5 robotic arm was designed and 3D printed. It includes openings for easy access to the buttons from the Pundit array as well as a reinforced structural design. The scan from the Pundit array can show the back-wall, rebars, and other defects to assist in determining the structural integrity. In order to scan, a program was made to search for the wall first. 1. The UR5 robotic arm will go to the desired location away from the wall. 2. It will then search for the wall by moving towards it slowly. 3. After contact, the force applied will slowly but steadily increase to a preset value inputted by the user. 4. The force torque sensor will use those values and communicate with the UR5 by adjusting the arm to become normal to the wall. 5. The arm will then apply force to push back the transducers on the Pundit array to avoid gaps. 6. It will then prompt the user to collect data and wait until finished. The UR5 teach pendant allows the user to program the robot to perform automated and repeatable tasks. It includes a free drive mode which allows the user to move the arm to a desired position by hand. The user can also apply restricted planes which include either stopped or slower motion to ensure safety. The concrete sample being tested includes rebars and different grades of surface roughness to understand the readings from the Proceq Pundit 250 array. Desired concrete samples are currently being fabricated that will simulate the terrain being tested.

3D PRINTING↗

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗