Search NASA⌕ Search

SEARCH · Search NASA

Results for “Examination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Postirradiation examination from separate effects irradiation testing of uranium nitride kernels and coated particles

An overview of postirradiation examination results for uranium nitride kernels and uranium nitride coated particles irradiated in the High Flux Isotope Reactor are presented. This is the first postirradiation examination of the MiniFuel irradiation vehicle that was recently developed to rapidly accumulate burnup during separate effects irradiation testing. In general, the burnup and fuel temperatures measured postirradiation were consistent with the design calculations. The burnup measured by mass spectrometry ranged from 5.9 to 10 MWd/kgU and was achieved after only 68 effective full-power days of irradiation. The dilatometric evaluation of passive silicon carbide thermometry indicated that the fuel was irradiated at temperatures ranging from 410 to 460 °C. Because the irradiation temperatures and burnup were low, the UN kernels showed minimal fission gas release that was within the range of the expected recoil (athermal) release. While it is possible to measure fuel swelling using x-ray computed tomography, the observed swelling was too small to quantify in this case. Extensive microstructural characterization of the irradiated fuel was performed in this study, and no significant irradiation induced changes were observed.

36 MATERIALS SCIENCE↗

Examination of core samples from the Mount Elbert Gas Hydrate Stratigraphic Test Well, Alaska North Slope: Effects of retrieval and preservation

Collecting and preserving undamaged core samples containing gas hydrates from depth is difficult because of the pressure and temperature changes encountered upon retrieval. Hydrate-bearing core samples were collected at the BPXA-DOE-USGS Mount Elbert Gas Hydrate Stratigraphic Test Well in February 2007. Coring was performed while using a custom oil-based drilling mud, and the cores were retrieved by a wireline. The samples were characterized and subsampled at the surface under ambient winter arctic conditions. Samples thought to be hydrate bearing were preserved either by immersion in liquid nitrogen (LN), or by storage under methane pressure at ambient arctic conditions, and later depressurized and immersed in LN. Eleven core samples from hydrate-bearing zones were scanned using x-ray computed tomography to examine core structure and homogeneity. Features observed include radial fractures, spalling-type fractures, and reduced density near the periphery. These features were induced during sample collection, handling, and preservation. Isotopic analysis of the methane from hydrate in an initially LN-preserved core and a pressure-preserved core indicate that secondary hydrate formation occurred throughout the pressurized core, whereas none occurred in the LN-preserved core, however no hydrate was found near the periphery of the LN-preserved core. To replicate some aspects of the preservation methods, natural and laboratory-made saturated porous media samples were frozen in a variety of ways, with radial fractures observed in some LN-frozen sands, and needle-like ice crystals forming in slowly frozen clay-rich sediments. Suggestions for hydrate-bearing core preservation are presented.

54 ENVIRONMENTAL SCIENCES↗

Using Simulation to Examine the Effect of MPI Message Matching Costs on Application Performance

Attaining high performance with MPI applications requires efficient message matching to minimize message processing overheads and the latency these overheads introduce into application communication. We use a validated simulation-based approach to examine the relationship between MPI message matching performance and application time-to-solution. Specifically, we examine how the performance of several important HPC workloads is affected by the time required for matching. Our analysis yields several important contributions: (i) the performance of current workloads is unlikely to be significantly affected by MPI matching unless match queue operations get much slower or match queues get much longer; (ii) match queue designs that provide sublinear performance as a function of queue length are unlikely to yield much benefit unless match queue lengths increase dramatically; and (iii) we provide guidance on how long the mean time per match attempt may be without significantly affecting application performance. The results and analysis in this paper provide valuable guidance on the design and development of MPI message match queues.

97 MATHEMATICS AND COMPUTING↗

Examining the Reactions of Ethanolamine’s Thermal Degradation Compounds in Carbon Capture through 1 H NMR and 13 C NMR

In amine scrubbing carbon capture, concerns about amine solvent degradation include whether it can affect the ability of the solvent to capture CO 2 . This study examines the interactions between the three most reported monoethanolamine (MEA) thermal degradation compounds namely, oxazolidine-2-one (OZD), N-(2-hydroxyethyl)-ethylenediamine (HEEDA), and N-(2- hydroxyethyl)-imidazoline-2-one (HEIA) with CO 2 in the presence and absence of MEA. We compared 1 H NMR, 13 C NMR, and heteronuclear single-quantum coherence (HSQC) NMR for neat OZD, HEEDA, and HEIA samples with CO 2 -loaded samples to observe changes in protonation and unique carbamate species formation. We found that OZD and HEIA did not directly react with CO 2 or undergo proton shifting based on our comparison of the neat OZD and HEIA samples with CO 2 -loaded spectra. However, we observed that the OZD can protonate when sparged with CO 2 in the presence of MEA, which suggests that the OZD acts as an intermediate. The NMR spectra for HEEDA indicated that HEEDA directly reacts with CO 2 at both amino groups and can protonate. In the presence of MEA, HEEDA and MEA can act like a solvent blend, resulting in multiple carbamates forming within the solvent. The neat HEIA spectrum, compared with CO 2 -loaded HEIA spectra, revealed similar results as OZD, where it does not react with CO 2 or protonate directly. However, HEIA does not protonate in the presence of MEA. These degradation compound reactions can increase the number of general equilibrium reactions during carbon capture and impact the model MEA solvent. This work helps provide a more complete picture of the reactions as the solvent degrades. Although this study examines CO 2 effects on thermal degradation products for MEA, other amines such as piperazine or 1- amino-3-propanol will degrade, and the degradation may speciate similarly with CO 2 . Furthermore, this study can impact and improve process models by assessing the degradation compounds’ reactions with CO 2 and potentially incorporating them into the model based on a neat solvent.

20 FOSSIL-FUELED POWER PLANTS↗

Crystallographic Texture, Structure, and Stress Transmission in Nugget Sandstone Examined With X‐Ray Tomography and Diffraction Microscopy

Subsurface processes in sandstones are controlled by porosity, permeability, and deformation mechanisms, all of which are controlled by a complex interplay of crystallographic rock texture, structure, and micromechanics. Texture, structure, and micromechanics have historically been studied using optical and electron microscopy of thin-sections. Here, we employed a new combination of in situ X-ray tomography and ray diffraction microscopy to study crystallographic texture, structure, and grain stresses in 3D. We examined these features in a sample of Nugget sandstone, a sandstone constituting hydrocarbon reservoirs across the American West. Our aims are threefold. First, we demonstrate the utility of X-ray diffraction microscopy probes for revealing texture, structure, and stress transmission in 3D. Second, we apply these techniques to Nugget sandstone and discuss findings in the context of prior work. Third, we study grain stress tensor evolution during mechanical compression to examine whether their heterogeneity and orientation evolution reflect that of inter-particle forces in granular materials. Our results show: (a) larger grains featured higher intra-granular misorientations, possibly from an increased prevalence of cements; (b) pores closed parallel to the loading direction and opened normal to loading; (c) grain stresses featured heterogeneity and orientations similar to inter-particle forces in non-cohesive granular materials; (d) grains featured compressive stresses in the loading direction and tensile stresses orthogonal to the loading direction, the latter resisting sample dilation and grain separation. Our work demonstrates the first known application of multi-modal X-ray tomography and diffraction microscopy to sandstone, providing new 3D insight into the nature of quartz cement and stress evolution.

high energy diffraction microscopy↗

Quantifying dislocation-type defects in post irradiation examination via transfer learning

The quantitative analysis of dislocation-type defects in irradiated materials is critical to materials characterization in the nuclear energy industry. The conventional approach of an instrument scientist manually identifying any dislocation defects is both time-consuming and subjective, thereby potentially introducing inconsistencies in the quantification. This work approaches dislocation-type defect identification and segmentation using a standard open-source computer vision model, YOLO11, that leverages transfer learning to create a highly effective dislocation defect quantification tool while using only a minimal number of annotated micrographs for training. This model demonstrates the ability to segment both dislocation lines and loops concurrently in micrographs with high pixel noise levels and on two alloys not represented in the training set. Inference of dislocation defects using transmission electron microscopy on three different irradiated alloys relevant to the nuclear energy industry are examined in this work with widely varying pixel noise levels and with completely unrelated composition and dislocation formations for practical post irradiation examination analysis. Code and models are available at https://github.com/idaholab/PANDA.

36 MATERIALS SCIENCE↗

Examination of the photoinitiation processes in photopolymer materials

Holographic data storage requires multiple sequential short exposures. However, the complete exposure schedule may not necessarily occur over a short time interval. Therefore, knowledge of the temporally varying absorptive effects of photopolymer materials becomes an important factor. In this paper, the time varying absorptive effects of an acrylamide/polyvinylalcohol photopolymer material are examined. These effects are divided into three main photochemical processes, which following identification, are theoretically and experimentally examined. These processes are (i) photon absorption, (ii) photosensitizer recovery, and (iii) photosensitizer bleaching.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new tensile stage for in situ electron microscopy examination of the mechanical properties of 'superelastic' specimens

We have developed a novel tensile stage that can be used for in situ electron microscopy examination of the mechanical properties of ''superelastic'' materials. In our stage, one of the specimen clamps is replaced by a cylindrical roller, which when driven by a motor can easily stretch (''roll on'') any specimen irrespective of its plastic properties. We have used the so-called Roll-o-meter in the study of the tensile behavior of two different film formed latex formulations, here referred to as standard and novel. We find that the values of the tensile strength and extension to break of the studied systems, measured by using the Roll-o-meter, are similar to those measured by a Hounsfield tensile testing machine outside the microscope chamber. Further, in situ environmental scanning electron microscopy examination of the deformation and failure of the lattices revealed that the standard specimens exhibit a more ductile behavior, compared to the novel ones.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct examination of cadmium bonding in rat tissues dosed with mine wastes and cadmium-containing solutions

Direct examination by XANES and EXAFS of metal bonding in tissue can be demonstrated by examining cadmium uptake and bonding in animal tissue maintained at cryogenic temperatures. XANES at the K-edge of cadmium were collected at the Photon Factory Advanced Ring (PF-AR), NW10A beam line at KEK-Tsukuba-Japan. Rats fed with 1g mine waste containing 8-400 mg/kg cadmium per 200g body weight (b.w.) or dosed by oral gavage with either cadmium chloride solution alone (at 6 mg/kg b.w.) or in combination with other salts (As, Cu or Zn), 5 days/week for 6 weeks, had 0.1-7.5 and 8-86 mg/kg cadmium in the liver or kidney, respectively. Rats given intraperitoneally (ip) or intravenously (iv) 1-4 times with 1 mg/kg b.w. cadmium solution had 30-120 mg/kg cadmium in the liver or kidney. Tissues from rats were kept and transferred at cryogenic temperature and XANES were recorded at 20 K. The spectra for rat liver samples suggested conjugation of cadmium with glutathione or association with the sulfide bond (Cd-S) of proteins and peptides. EXAFS of rat liver fed by Cd and Zn solutions showed that Cd was clearly bound to S ligands with an inter-atomic distance of 2.54 A ring for Cd-S that was similar to cadmium sulfide with an inter-atomic distance of 2.52 A ring for Cd-S. Liver or kidney of rats fed with mine wastes did not give an edge in the XANES spectra indicating little uptake of cadmium by the animals. Longer and higher dosing regimen may be required in order to observe the same Cd-S bond in the rat tissue from mine wastes, including confirmation by EXAFS.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Radiation assessment to paediatric with F-18-FDG undergo whole-body PET/CT examination

This study was carried out on wholebody radiation dose assessment to paediatrics patient who undergo PET/CT scanner at Institut Kanser Negara. Consist of 68 patients with varies of malignancies and epilepsy disease case covering age between 2 years to 12 years old. This is a retrospective study from 2010-2014. The use of PET/CT scanner as an advanced tool has been proven to give an extra radiation dose to the patient. It is because of the radiation exposure from the combination of both CT and PET scans rather than a single CT or PET scan. Furthermore, a study on radiation dose to paediatric patient undergoing PET/CT is rare in Malaysia. So, the aim of this study is to estimate the wholebody effective dose to paediatric patient in Malaysia. Effective dose from PET scan was calculated based on the activity of F18 FDG and dose coefficient reported in International Commission on Radiological Protection (ICRP) Publication 106. Effective dose from CT was determined using k coefficient as reported in ICRP publication 102 and Dose Length Product (DLP) value. The average effective dose from PET and CT were found to be 7.05mSv and 5.77mSv respectively. The mean wholebody effective dose received by a patient with combined PETCT examination was 12.78mSv. These results could be used as reference for dosimetry of a patient undergoing PETCT examination in Malaysia.

07 ISOTOPE AND RADIATION SOURCES↗

Examination of Uranium(VI) Leaching During Ligand Promoted Dissolution of Waste Tank Sludge Surrogates

The dissolution of synthetic boehmite (?-AlOOH) by 1-hydroxyethane-1,1-diphosphonic acid (HEDPA) was examined in a series of batch adsorption/dissolution experiments. Additionally, the leaching behavior of {sup 233}U(VI) from boehmite was examined as a function of pH and HEDPA concentration. The results are discussed in terms of sludge washing procedures that may be utilized during underground tank waste remediation. In the pH range 4 to 10, complexation of Al(III) by HEDPA significantly enhanced dissolution of boehmite. This phenomenon was especially pronounced in the neutral pH region where the solubility of aluminum, in the absence of complexants, is limited by the formation of sparsely soluble aluminum hydroxides. At pH higher than 10, dissolution of synthetic boehmite was inhibited by HEDPA, likely due to sorption of Al(III):HEDPA complexes. Addition of HEDPA to equilibrated U(VI)-synthetic boehmite suspensions yielded an increase in the aqueous phase uranium concentration. Partitioning of uranium between the solid and aqueous phase is described in terms of U(VI):HEDPA speciation and dissolution of the boehmite solid phase.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Examination of probability distribution of mixture fraction in LES/FDF modelling of a turbulent partially premixed jet flame

An accurate prediction of the probability density function (PDF) of the mixture fraction is crucial to the prediction of combustion since mixing plays an important role in turbulent non-premixed and partially premixed flames. This work provides an assessment of the large-eddy simulation (LES)/filtered density function (FDF) method for the prediction of the PDF of the mixture fraction. The advantage of the LES/FDF method is that it provides the full predictions of the statistical distribution of scalars including the mixture fraction. The predictive accuracy of the method for the PDF is yet to be fully validated. Assessing the prediction of the PDF of the mixture fraction, a conserved scalar, is an important starting point. The Sydney/Sandia inhomogeneous inlet jet flame is used as a test case. A quick comparison shows that the LES/FDF predicted PDF shapes of the mixture fraction deviate significantly from the commonly presumed Beta-PDF as well as from the experimental data in the flame. Here, to examine the source of the discrepancy, we clarify the different PDF definitions used in the comparison among the predictions, measurements, and the presumed shape PDFs. The discrepancy observed from the comparison is largely reconciled by clarifying the difference between the PDFs that are examined. The PDF of the resolved mixture fraction is shown to be close to the Beta-PDF in both the measurements and predictions, while the PDF directly deduced from the LES/FDF particles deviates significantly from the Beta-PDF. A multimodal PDF analysis and a pseudo convergence analysis are conducted to provide plausible evidence to support the predicted multimodal PDF shapes. The sub-filter scale FDF is shown to be close to the Beta-PDF too through the construction of a synthesized PDF, which supports the common presumed Beta-PDF assumption used in the presumed PDF methods when combined with LES.

42 ENGINEERING↗

A SPECTROSCOPIC EXAMINATION OF ACCRETION DIAGNOSTICS FOR NEAR SOLAR MASS STARS IN IC 348

High-resolution optical and moderate-resolution near-infrared spectra were obtained for 40 near solar mass ({approx}2.0-0.5 M{sub sun}) members of the 2-3 Myr old cluster IC 348 in order to examine established accretion diagnostics and the coupling between inner disk gas and hot, micron-sized dust grains inferred from thermal and mid-infrared excesses. The stellar sample was drawn from the cluster census of Luhman in 2003 with membership being confirmed by radial velocity analysis and the presence of strong Li I {lambda}6708 absorption. Of the stars included in this survey, 12 were classified by Lada in 2006 as hosting primordial, optically thick circumstellar disks, 5 as weak or transition disk systems, and 23 as non-excess stars using the measured slope of the stellar spectral energy distribution (SED) through the four Infrared Array Camera channels (3.6-8.0 {mu}m) of Spitzer Space Telescope. Using the velocity width of H{alpha} as an accretion indicator, we find that 11 primordial disk candidates are suspected accretors, suggesting a strong correlation between gaseous inner disks and optically thick dust emission. Of the five weak or transition disk systems observed, two (L21 and L67) exhibit spectroscopic features indicative of accretion. The presence of gas within the inner disk of these systems, which are free of infrared excess emission shortward of {approx}4.5 {mu}m, may place constraints upon the physical mechanism responsible for inner disk clearing. Mass accretion rates ( M-dot ) were determined for all suspected accretors using continuum excess measurements near {lambda}6500 and established relationships between He I {lambda}5876, H{alpha}, Ca II {lambda}8542, Pa{beta}, and Br{gamma} line fluxes and accretion luminosity. M-dot values were found to range from log M-dot = -8.7 to -7.2 M{sub sun} yr{sup -1}, with a median value of -8.1 M{sub sun} yr{sup -1}. Magnetospheric accretion models of H{alpha}, Pa{beta}, and Br{gamma} emission by Muzerolle et al. and Kurosawa et al. are found to be in relative agreement with observed fluxes and derived M-dot estimates. He I {lambda}10830 with its metastable lower level is confirmed to be a critical indicator of magnetospheric accretion, although deep subcontinuum absorption profiles often associated with its emission are not fully understood. No statistically significant correlation is found between M-dot and the slope of the SED from 3.6 to 8.0 {mu}m or from 8.0 to 24.0 {mu}m; however, the small number of suspected accretors examined does not allow broader conclusions to be drawn.

79 ASTRONOMY AND ASTROPHYSICS↗

Theoretical and Experimental Examination of the Intermediate-Band Concept for Strain-Balanced (In,Ga)As/Ga(As,P) Quantum Dot Solar Cells

The intermediate-band solar cell (IBSC) concept has been recently proposed to enhance the current gain from the solar spectrum while maintaining a large open-circuit voltage. Its main idea is to introduce a partially occupied intermediate band (IB) between the valence band (VB) and conduction band (CB) of the semiconductor absorber, thereby increasing the photocurrent by the additional VB {yields} IB and IB {yields} CB absorptions. The confined electron levels of self-assembled quantum dots (QDs) were proposed as potential candidates for the implementation of such an IB. Here we report experimental and theoretical investigations on In{sub y}Ga{sub 1-y}As dots in a GaAs{sub 1-x}P{sub x} matrix, examining its suitability for acting as IBSCs. The system has the advantage of allowing strain symmetrization within the structure, thus enabling the growth of a large number of defect-free QD layers, despite the significant size mismatch between the dot material and the surrounding matrix. We examine the various conditions related to the optimum functionality of the IBSC, in particular those connected to the optical and electronic properties of the system. We find that the intensity of absorption between QD-confined electron states and host CB is weak because of their localized-to-delocalized character. Regarding the position of the IB within the matrix band gap, we find that, whereas strain symmetrization can indeed permit growth of multiple dot layers, the current repertoire of GaAs{sub 1-x}P{sub x} barrier materials, as well as In{sub y}Ga{sub 1-y} As dot materials, does not satisfy the ideal energetic locations for the IB. We conclude that other QD systems must be considered for QD-IBSC implementations.

14 SOLAR ENERGY↗

Ab initio based examination of the kinetics and thermodynamics of oxygen in Fe-Cr alloys

The behavior of oxygen in Fe-Cr binary alloys is important to understand for a variety of applications including fuel cell interconnects and nuclear energy systems. In this work, we performed an ab initio investigation of the binding of oxygen in the entire compositional range of Fe-Cr at minima and saddles. This database was subsequently used to parametrize concentration-dependent local cluster expansions which were utilized to examine the kinetics of oxygen transport in the alloy and the thermodynamics of the system. The behavior of oxygen in the alloy system was investigated using our cluster expansion model and a convex hull diagram was recorded. The most favorable composition for the incorporation of oxygen was found to occur at 70% Cr. The dependence of the oxygen solution energy on the Cr occupation of the nearest neighbor shells was carefully characterized. It was determined that the third nearest neighbor Cr occupation was unfavorable and that, generally speaking, the first and second nearest neighbor shell Cr occupation was favored with a few exceptions. Kinetic Monte Carlo models at dilute oxygen levels were performed using two models [a kinetically resolved activation (kRA) model and a cluster expansion model for the saddle points]. The models qualitatively agreed with the observed trends in the literature which reported a decrease in diffusivity at dilute Cr levels, but the models predicted different behaviors beyond the dilute Cr limit. Finally, using grand canonical Monte Carlo, we further examined the thermodynamics of oxygen incorporation into the alloy. Furthermore, our results offer new insight into the behavior of oxygen in Fe-Cr alloys that have ramifications on the early stages of the corrosive behavior of the material.

36 MATERIALS SCIENCE↗

Development of a patient-specific dosimetry estimation system in nuclear medicine examination

The purpose of this study is to develop a patient-specific dosimetry estimation system in nuclear medicine examination using a SimSET-based Monte Carlo code. We added a dose deposition routine to store the deposited energy of the photons during their flights in SimSET and developed a user-friendly interface for reading PET and CT images. Dose calculated on ORNL phantom was used to validate the accuracy of this system. The S values for {sup 99m}Tc, {sup 18}F and {sup 131}I obtained by the system were compared to those from the MCNP4C code and OLINDA. The ratios of S values computed by this system to those obtained with OLINDA for various organs were ranged from 0.93 to 1.18, which are comparable to that obtained from MCNP4C code (0.94 to 1.20). The average ratios of S value were 0.99{+-}0.04, 1.03{+-}0.05, and 1.00{+-}0.07 for isotopes {sup 131}I, {sup 18}F, and {sup 99m}Tc, respectively. The simulation time of SimSET was two times faster than MCNP4C's for various isotopes. A 3D dose calculation was also performed on a patient data set with PET/CT examination using this system. Results from the patient data showed that the estimated S values using this system differed slightly from those of OLINDA for ORNL phantom. In conclusion, this system can generate patient-specific dose distribution and display the isodose curves on top of the anatomic structure through a friendly graphic user interface. It may also provide a useful tool to establish an appropriate dose-reduction strategy to patients in nuclear medicine environments. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Capturing high‐resolution digital images for use in forensic document examination

Abstract In the past, pattern disciplines within forensic science have periodically faced criticism due to their subjective and qualitative nature and the perceived absence of research evaluating and supporting the foundations of their practices. Recently, however, forensic scientists and researchers in the field of pattern evidence analysis have developed and published approaches that are more quantitative, objective, and data driven. This effort includes automation, algorithms, and measurement sciences, with the end goal of enabling conclusions to be informed by quantitative models. Before employing these tools, forensic evidence must be digitized in a way that adequately balances high‐quality detail and content capture with minimal background noise imparted by the selected technique. While the current work describes the process of optimizing a method to digitize physical documentary evidence for use in semi‐automated trash mark examinations, it could be applied to assist other disciplines where the digitization of physical items of evidence is prevalent. For trash mark examinations specifically, it was found that high‐resolution photography provided optimal digital versions of evidentiary items when compared to high‐resolution scanning.

Riley, Paige↗

Sulphate resistance of low‐clinker engineered cementitious composites examined by MicroXRF imaging

Abstract Engineered cementitious composites (ECC) are a class of high‐performing fibre‐reinforced cementitious materials recognised for their increased ductility and durability compared to conventional cement‐based materials, owing to their autogenously controlled tight crack widths, even when subjected to high strains. To reduce ECC's environmental impact, this research examines the use of a low‐clinker binder − limestone‐calcined clay cement (LC3) − as an alternative to portland cement (PC), along with fly ash to further reduce the clinker proportion and the embodied CO 2 of the formulations. In conventional concrete, LC3 hydrates to a denser microstructure resulting from the synergistic reaction between limestone and calcined clay. At the lower water contents typical of ECC and with the presence of fly ash, the influence of the binder composition on the microstructure is difficult to anticipate. To examine the influence of these compositional variables on microstructure, permeability and durability, the sulphate resistance of LC3‐based ECC is explored. Specifically, the ECC‐LC3 blends are designed with high clinker replacement rate of 75% by mass of binder and contain either conventional fly ash or reclaimed fly ash at 50% by mass of binder. Expansion of ECC‐LC3 samples subjected to standard sodium sulphate test conditions was measured up to 12 months and the depth of penetration of sulphates into the ECC‐LC3 of varying compositions was quantified using micro‐X‐Ray Fluorescence (microXRF) imaging and modelling. The expansion results show that the ECC‐LC3 formulations performed better than the PC samples and can provide adequate resistance to external sulphate attack, even when reclaimed fly ashes are used in place of the conventional ash. In addition, the shallow penetration of sulphate into these cementitious composites demonstrates the low diffusion coefficients values that were determined using the quantitative data from MicroXRF imaging.

Microscopy↗