Search NASA⌕ Search

SEARCH · Search NASA

Results for “Experimental Test Range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Formulation, Design and Experimental Verification of an Open Circuit Electro-Hydraulic Actuator

With the recent electrification trend in the fluid power area, more research has been incentivized to the proposal of cost-effective and energy-efficient solutions for hydraulic systems. Hence, electro-hydraulic actuator (EHA) architectures receive increasing attention. The paper proposes a novel open-circuit EHA architecture, with the goal to obtain a cost-effective mobile solution while maximizing the overall system efficiency. The proposed EHA is capable of meeting or exceeding traditional off-road machine performance, therefore enabling further electrification of off-road machines. Four-quadrant functionality, covering the full speed range, is achieved by a combination of a variable electro-hydraulic drive and valves with different functions and is validated by numerical as well as experimental methods. Here, a simulation model based on the Amesim environment and a dedicated test setup was developed to verify the performance. The good match between simulation and experimental results confirms the potential of the formulation approach of the proposed EHA for applications with different duty cycles and power levels.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental validation of an organic rankine-vapor compression cooling cycle using low GWP refrigerant R1234ze(E)

There is a significant global opportunity to capture and utilize low grade waste heat to reduce fossil fuel consumption, greenhouse gas emissions, and improve energy efficiency across a wide range of industries. In this work, an advanced type of thermally activated cooling system, an organic Rankine-vapor compression cycle (ORVC) with novel heat integration strategies, was designed and tested at a relevant scale for industrial waste heat recovery (300 kW th cooling capacity). The ORVC linked an organic Rankine power cycle and a vapor compression cooling cycle using a turbine and compressor that shared a single shaft. The ORVC test facility absorbed waste heat from a liquid stream at 91 °C to simulate engine coolant in diesel generator sets, rejected heat to a glycol stream at 30 °C, and generated chilled water at 7 °C. A cooling capacity of 264 kW ± 3.5 kW was experimentally validated with a COP of 0.56 ± 0.01 during steady-state operation at the design temperatures. The thermal efficiency, accounting for pump work, of the Rankine cycle was 7.7% ± 0.22% and the COP of the vapor compression cycle was 5.25 ± 0.09. The centrifugal turbo-compressor operated at 31.5 kRPM ± 0.3 kRPM, with a turbine and compressor isentropic efficiencies of 76.7% ± 0.90% and 84.8% ± 0.54%, respectively, with near-perfect power transmission between these components. The pressure drop in the piping and heat exchangers were significantly larger than expected which had a detrimental impact on the performance of the ORVC. In addition, the condenser on the cooling cycle could not deliver the subcooling as specified from the design point modeling. Furthermore, the results from the sensitivity analysis showed that the higher condenser glycol outlet temperature had the largest impact on performance, which is consistent with other analytical models in the literature. When the ORVC simulations were updated with experimental values for isentropic efficiencies of the turbomachinery, the thermal COP was 0.66 which represents an estimate of the predicted performance if test facility limitations are overcome.

30 DIRECT ENERGY CONVERSION↗

Investigation of Flux Spreading in a Light-Trapping, Planar-Cavity Receiver for Enclosed Solar Particle Heating

Concentrating solar thermal power (CSP) technology development has recently focused on increasing the operating temperatures to accommodate high efficiency power cycles and thermochemical processes. Inert solid particles as heat transfer media enable solar receivers to operate above 700 degrees Celsius resulting in increased system thermal efficiency compared to the conventional molten salt based CSP system. An open-cavity falling-particle solar receiver that can efficiently heat particles by direct heating from concentrated solar radiation faces challenges with large particle losses from wind and unable to support thermochemical reactions. A light-trapping, planar cavity reiver (LTPCR) where particles are indirectly heated can significantly minimize the particle losses during the operation, support thermochemical reactions, and offer scalability potential. The LTPCR features an array of vertical planar receiver/absorber panels arranged within a cavity configuration. Concentrated solar radiation from heliostats is focused onto the receiver walls, where heat is indirectly transferred to solid particles flowing inside the receiver channels. Heat transfer occurs through direct contact between the receiver panel walls and particles, and can be enhanced by fluidizing particles with air. This fluidization increases particle-wall contact and extends particle residence time, maximizing heat transfer efficiency. The unique vertical planar receiver structure originated from a near-blackbody tubular light absorber, effectively distributing the incoming solar beam spread across the panel walls and trapping light. This flux spreading effect, driven by cosine projection, converts high incident solar flux into a lower, more uniform heat flux on the panel walls. This redistribution enhances heat transfer efficiency between particle-wall or reaction gases-wall, while preventing localized overheating of the receiver panel. Indirect planar cavity solar receivers completely separate solid particles from the ambient environment that can greatly reduce the thermal losses in heated particles resulting in high efficiency at high temperatures above 700 degrees Celsius. This design ensures no particle losses to the environment during the operation while open-cavity designs can experience significant particle losses from wind. An experimental investigation was conducted to observe flux spreading on the receiver panel wall. A lab-scale prototype planar receiver, fabricated using Haynes 230 alloy, was tested under direct concentrated solar radiation using the high-flux solar furnace (HFSF) facility at NREL. The experiment was performed under normal peak radiative heat fluxes ranging from 800 to 1900 kW/m2. A temperature distribution on the panel wall was measured using a thermal imaging camera (FLIR A 6600). To prevent overheating at the receiver front tip, prism-shaped heat shields (Zircar UNIFROM C1) were placed in front of the receiver, and their influence on flux spreading was also studied. Absorbed flux distribution on the panel wall was modeled using SolTrace. The total solar power and flux distributions delivered from HFSF were determined based on the heliostat mirror optical properties, direct normal irradiance (DNI) on the on-sun testing days, peak flux measurement during the on-sun testing, and shutter/attenuator settings Due to the large incident angles of the solar beam on the panel wall, the angular optical properties of Haynes 230 alloy and Zircar heat shields were incorporated into the model. This flux distribution model was then integrated into a computational fluid dynamics (CFD) simulation to predict the receiver panel wall temperature, which was compared with the experimental measurements. Both prediction and measurements identified a temperature hotspot at the backside of the panel, indicating that the incident solar beam can fully reach to the rear of the receiver. The heat shields positioned at the front of the receiver effectively reduced the excessive temperature rise at the receiver front tip. Overall, the temperature was well distributed over the panel wall, with a minor hotspot at the back of the receiver. The model slightly overpredicted the temperature, possibly due to discrepancies in optical properties of the panel and an underprediction of thermal loss in the receiver. The advancement of the particle LTPCR offers a viable alternative to open-cavity receivers by addressing particle loss issues. Additionally, it presents a pathway for enabling solar thermochemical processes, extending CSP technology beyond power generation to fuel and chemical production.

14 SOLAR ENERGY↗

A unified thermionic and thermionic-field emission (TE–TFE) model for ideal Schottky reverse-bias leakage current

We present a unified thermionic emission (TE) and thermionic-field emission (TFE) model for the ideal reverse-bias leakage current in Schottky junctions. The unified TE–TFE analytical model advances upon previous analytical TFE models by Murphy–Good and Padovani–Stratton, which are the two most widely adopted models by the community, in two major aspects: (i) the applicability of the TFE expression therein is extended to near-zero surface electric fields by an error-function correction, allowing for the calculation of the total current by a nontrivial sum of TE (over-the-barrier current) and TFE (below-the-barrier current) contributions; therefore, an accurate description of the TE-to-TFE transition region is captured analytically for the first time; (ii) image-force lowering is considered with much-simpler correction terms. Comparisons with the reference numerical model show that the unified TE–TFE model has excellent accuracy, as well as a 10 000× reduction in computation time. The unified model is further tested against experimental data from Schottky barrier diodes based on Si, 4H-SiC, GaN, and β-Ga 2 O 3 , revealing accurate extractions of barrier heights and correct descriptions of the ideal reverse leakage characteristics. With the extended applicable range, improved accuracy, and computational efficiency, the unified TE–TFE model is highly valuable for the design and analysis of devices based on Schottky junctions, as well as for potential integration in technology computer-aided design (TCAD) tools.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Water Energy Resource Innovation on the Cavitation Characteristics

The main purpose of this study is to numerically correlate the amount of generated vapor over a hydrofoil to the lift and drag coefficients acting on it. As such, cavitation characteristics were investigated of a hydrofoil in the cavitating, sub-cavitating, and non-cavitating flows for different angles of attacks (AoA) with the high upstream flow velocity. The hydrofoil was tested in a square water tunnel with water entering the tunnel at various velocities for each AoA ranges from 9.1 m/s to 12.2 m/s. It was found that lift and drag forces acting on the hydrofoil follow the trend of the experimental data quite closely. While the cavitation can be identified by a unique number (averaged vapor volume fraction), the work done created an inverse correlation between this number and the cavitation number at the same angle of attack. The lift force declines with the increase in the vapor content on the hydrofoil surface, meanwhile the drag force peaks at certain vapor volume fraction, and then, a huge reduction occurs with the considerable decrease in the corresponding cavitation number. A fourth-order correlation generated between the lift to drag (L/D) and the cavitation number (σ). It was found the lift-to-drag ratio decreases by the formation of the cavitation over the hydrofoil, thus causing a drop in the efficiency of the turbomachines.

42 ENGINEERING↗

NETL Electrical Conductivity Relaxation(ECR) Analysis Tool

This application was developed within the solid oxide fuel cell (SOFC) work plan. It calculates the oxygen surface exchange coefficient (k) and oxygen diffusion coefficient (D) for an oxide sample using electrical conductivity relaxation (ECR) data. The tool also produces a heat map showing the associated uncertainty in fitting the ECR data for given pairs of k and D values, so the user can determine the most likely range of k and D values for the tested values. Multiple datasets for the same material can be plotted to decrease uncertainty. The tool can also simulate ECR curves for inputted k and D values and overlay the simulated curves with experimental data for comparison.

electrical conductivity relaxation↗

Performance Demonstration of Self-Powered Neutron Detectors for Steady-State Reactor Operations

The irradiation testing of sensors in reactors is a crucial step towards calibrating and qualifying sensors prior to their deployment in experiments. This report details the process toward qualifying and calibrating custom-designed rhodium-based self-power neutron detectors (Rh-SPNDs) for steady-state reactor irradiations. This process serves to both demonstrate the performance capabilities of Rh-SPNDs as well as to provide experimental data for development of a sensor sensitivity model. Two designs of Rh-SPNDs were tested in various reactors to demonstrate: detection resolution in a low neutron flux environment, a delayed-response compensation technique, output linearity in a large range of neutron flux, and measurement accuracy verified with dosimetry. The detection resolution and compensation technique was demonstrated in the AGN-201m reactor at Idaho State University. The irradiation confirmed the sensors’ capability to perform steady-state operations in a low neutron flux of ~2E8 n/cm 2 -sec. Sensor output linearity coupled with the delayed-response compensation was investigated at the neutron radiography reactor at Idaho National Laboratory. A Rh-SPND was irradiated to neutron fluxes ranging from 2E8 to 2E13 n/cm2-sec range. The measured data demonstrated a wide and linear range of operation with a measured linear sensitivity of 1.0129 ×10 -13 A/W with a correlation-squared value of r 2 =0.9927. The measurement accuracy was investigated at the Advanced Test Reactor Critical reactor. The SPNDs were inserted into a test vehicle with collocated flux wires. Two irradiations with different flux levels were performed, and the SPNDs relative measurement between the two irradiations was calculated to be 1.2613 ± 0.0153 for the small SPND design and 1.1809 ± 0.0108 for the large SPND design. Both SPND measurements fell between the co-axial dosimetry result, which reported 1.218 ± 0.047. Additionally, the preliminary MCNP model for calculating SPND sensitivity was developed in parallel to this work. Modeled neutron spectrum with measured magnitude was used for inputs to determine the simulated SPND output. The results showed an overestimation of signal strength by a factor of 5, which was expected because of model simplification. This leads to future modeling work to account for signal losses from additional physical properties, including high temperature environments for FY-21.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Speed OH-PLIF Diagnostics of Flame Flashback in Low Swirl Hydrogen-Enriched Flames

This paper reports flashback events observed in hydrogen-enriched flames stabilized in a low swirl burner (LSB) at atmospheric pressure and temperature conditions. The fundamentals of hydrogen-rich stable flames and spatiotemporal investigation of flashback phenomena were observed experimentally using a high-repetition-rate nanosecond (ns)-duration hydroxyl radical planar laser-induced fluorescence (OH-PLIF) diagnostic. Testing was conducted in an optically accessible pre-mixing section of a LSB with inlet pre-mixing velocities ranging from 5 to 10 m/s for methane and hydrogen (50 – 90% by mole) blends. Swirlers with two different turning angles, 26o and 33o, and three different perforated plate hole diameters, 1.08, 1.12 and 1.16 mm, with measured swirl numbers varying from 0.43 to 0.49 were used in this study at atmospheric temperature and pressure inlet conditions. The flashback propensity showed a dependence on the proximity of the lifted flame to the burner exit (termed as lift-off length, L) which was dependent on the pre-mixer velocity (V), hydrogen content (XH2) and equivalence ratio (ϕ) at constant temperature and pressure conditions. High-speed OH-PLIF images revealed lifted flames were first observed at low ϕ/ XH2 condition which then changed to a M-shaped flame attached to burner rim with the increase in ϕ/ XH2. Further increases in ϕ/XH2, depending upon other inlet parameters, triggered flame flashback into the pre-mixing section. Flashback occurred when burning began in the outer shear layer and the leading flame brush propagated into the nozzle. Such spatiotemporally resolved high-speed OH-PLIF imaging provides insights on different stages of flashback in a LSB – flashback initiation, transition of flame propagation from burner exit to the swirler and flashback to flame holding transition. Flame ϕ at flashback showed an expected linearly increasing trend with increasing V and decreasing XH2 and the conclusions drawn aligned well with detailed investigations. For identical inlet conditions, flashback propensity decreased with increasing perforated-plate hole diameter and increasing swirler vane angle.

Parajuli, Pradeep↗

Fabrication, Modeling, and Testing of a Prototype for Particle Thermal Energy Storage Containment

Increasing penetration of variable renewable energy resources requires the deployment of energy storage at a range of durations. Long-duration energy storage (LDES) technologies will fulfill the need to firm variable renewable energy resource output throughout the year. Conventional electrochemical batteries (e.g., lithium-ion) are uneconomical in this role due to high energy capacity costs. Thermal energy storage (TES) is one promising technology for LDES applications because of its siting flexibility and ease of scaling. Particle-based TES systems use low-cost solid particles that have higher temperature limits than the molten salts used in traditional concentrated solar power systems. A key component in particle-based TES systems is the containment silo for the high-temperature (> 1100 degrees C) particles. This study combined experimental testing and computational modeling methods to design and characterize the performance of a particle containment silo for LDES applications. A containment silo prototype was built at a laboratory scale and used to validate a congruent transient finite element analysis (FEA) model. The validation compared the actual and predicted temperature profile through the prototype over six days as the particles cooled from their initial temperature. The performance of a commercial scale (> 5 GWhth) was then characterized using the validated model. The transient FEA model was subject to several charge-discharge cycles to mimic a possible operating schedule. The commercial-scale model predicted a storage efficiency in excess of 95% after five days of storage with a design storage temperature of 1200 degrees C. Insulation material and concrete temperature limits were considered as well. The validation of the methodology means the FEA model can simulate a range of scenarios for future applications. This work supports the development of a promising LDES technology with implications for grid-scale electrical energy storage, but also for thermal energy storage for industrial process heating applications.

ENERGY STORAGE↗

Verification and validation of the Alternative Nonlinear Two-phase Subchannel (ANTS) code

The Alternative Nonlinear Two-phase Subchannel solver (ANTS) code was written to provide a fast-running, steady-state, pin-resolved modeling and simulation tool for analysis of common boiling water reactor (BWR) geometry and common operating conditions. ANTS has been integrated into the Virtual Environment for Reactor Application (VERA) core simulator software, where it can be used to provide a thermal/hydraulic (T/H) subchannel solution that is then used to provide neutronic feedback as well as perform the fuel depletion and temperature solution. Herein, this paper presents the rigorous analysis performed on the ANTS code, which includes both code and solution verification testing, benchmarking with the existing two-phase subchannel capability in VERA, CTF, and validation testing using popular two-phase experiments such as PWR Sub-channel and Bundle Tests (PSBT), BWR Full-size Fine-mesh Bundle Tests (BFBT), Risø, and FRIGG. This assessment was used to qualify ANTS for its intended applications before its use for core-scale, multiphysics BWR simulations. In general, it was found that agreement with experimental data was good; errors were within the range of experimental data uncertainty. Furthermore, code and solution verification confirmed that the governing equations and the most important closure terms were correctly implemented and behaving as expected.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Warpage-Resistant, Under-Extrusion-Free, High-Surface-Quality Additive Manufacturing Process for Polyethylene-Based Composite Radiation Shielding Material

Polyethylene (PE) is one of the best shielding materials for primary space radiation due to its high hydrogen content. For effective secondary neutron shielding, boron-rich fillers are incorporated to enhance performance. The semicrystalline nature and high thermal expansion coefficient of PE impede its adoption for in situ additive manufacture in space via the fused deposition modeling (FDM) 3D printing. Here, we developed an optimized PE blend to mitigate the effects of under-extrusion and warpage. Guided by studies on extrusion and warpage, we developed an optimal set of printing parameters for the proposed PE blend. The optimum PE blend─both in its pure form and when doped with fillers─has been tested on different FDM printers. The printed structures exhibit high and uniform density, smooth surfaces, no warpage, and competitive mechanical properties. The FDM-printed plates demonstrate efficient shielding from thermal neutrons, predicted via modeling and confirmed experimentally using extended Q-range small-angle neutron scattering.

additive manufacturing↗

Different bonding type along each crystallographic axis: Computational study of poly($\textit{p}$-phenylene terephthalamide)

Poly($\textit{p}$-phenylene terephthalamide) (PPTA) exhibits van der Waals (vdW) bonding along its $\textit{a}$ axis, hydrogen bonding along its $\textit{b}$ axis, and covalent bonding along its $\textit{c}$ axis. In this work, we explore the structural and mechanical properties of PPTA using density functional theory with various functionals including LDA, PBE, PBE+rVV10L, SCAN, and SCAN+rVV10, compared with available experiments. The hierarchy of nonempirical semilocal functionals LDA, PBE, and SCAN (not fitted to any multicenter bonded system) includes differing amounts of intermediate-range vdW interaction. rVV10 is the long-range vdW correction. (rVV10L differs from rVV10 only in the value of a range parameter.) Among the tested functionals, SCAN shows the best performance for the lattice parameters of PPTA along the two crystal directions involving vdW or hydrogen-bond interaction. The equilibrium lattice constants obtained by SCAN and PBE+rVV10L are closest to experimental data, while SCAN+rVV10 slightly overbinds the system. We study the mechanical response of PPTA by applying strain along three lattice directions. Due to the inclusion of vdW interaction, SCAN, PBE+rVV10L, and SCAN+rVV10 all exhibit correct bonding strain-energy curves. On the contrary, PBE strongly underestimates the vdW interaction needed to resist uniaxial stretching along the $\textit{a}$ axis. The Young's modulus and yield strength of PPTA are computed and compared with previous results. The experimental values are much smaller than the computed ones, mainly due to the fact that the PPTA fiber samples used for measurements are mechanically weaker than the perfect molecular crystals considered in the simulations. Interestingly, when a compressive uniaxial stress of 25 Kbar is applied along the $\textit{b}$ axis, a structural phase transition, in which the hydrogen bonds reform along one diagonal of the $\textit{ab}$ rectangle, is predicted by SCAN.

36 MATERIALS SCIENCE↗

Translating macroecological models to predict microbial establishment probability in an agricultural inoculant introduction

The use of potentially beneficial microorganisms in agriculture (microbial inoculants) has rapidly accelerated in recent years. For microbial inoculants to be effective as agricultural tools, these organisms must be able to survive and persist in novel environments while not destabilizing the resident community or spilling over into adjacent natural ecosystems. Despite the importance of propagule pressure to species introductions, few tools exist in microbial ecology to predict the outcomes of agricultural microbial introductions. Here, we adapt a macroecological propagule pressure model to a microbial scale and present an experimental approach for testing the role of propagule pressure in microbial inoculant introductions. We experimentally determined the risk-release relationship for an IAA-expressing Pseudomonas simiae inoculant in a model monocot system. We then used this relationship to simulate establishment outcomes under a range of application frequencies (propagule number) and inoculant concentrations (propagule size). Our simulations show that repeated inoculant applications may increase establishment, even when increased inoculant concentration does not alter establishment probabilities. Applying ecological modeling approaches like those presented here to microbial inoculants may aid their sustainable use and provide a monitoring tool for microbial inoculants.

59 BASIC BIOLOGICAL SCIENCES↗

Using "AI Poincare" to analyze non-linear integrable optics

This study dives into the applicability of using automated discovery of conserved quantities in dynamical systems relevant to accelerator physics. Specifically, we explore the performance of AI Poincaré in analyzing numerical trajectory data obtained using the McMillan system of non-linear integrable optics. A comprehensive evaluation of the algorithm's performance is conducted through diverse methodologies. These include the analysis of the estimated number of conserved quantities embedded in a dataset and the deviation of interpolated points on the inferred manifold with respect to points in actually in the dataset. the investigation identifies an optimal range of perturbation distances where the underlying manifold extraction algorithm inside AI Poincaré exhibits optimal performance. Additionally, an improved neural network architecture is proposed based on the observed results. Finally, we apply the algorithm to preliminary experimental data from the Integrable Optics Test Accelerator at Fermilab to successfully infer the number of conserved quantities even in the presence of fast decoherence of the measured signal.

Osmanov, Lazare [Free U. Tbilisi]↗

Experimental and numerical investigation of proppant embedment and conductivity reduction within a fracture in the Caney Shale, Southern Oklahoma, USA

The current worldwide energy supply is insufficient to meet the rising demand. As a result, the energy prices are expected to keep soaring despite the recent increases in a variety of renewable energy resources. Although not renewable, shale oil and gas — “unconventional” hydrocarbon resources are relatively clean forms of energy resources, which still hold a vast share of the energy market. For many oil and gas companies, meeting profitable production goals from shale reservoirs is sometimes challenging, due to the loss of fracture conductivity and premature declines in the production. In this paper we investigate the stress-dependent changes in the hydraulic conductivity of proppant-filled fractures and mechanical fracture–proppant interactions in Caney Shale, a calcareous, organic-rich mudrock, through laboratory experiments and numerical modeling. American Petroleum Institute (API) fracture conductivity tests were conducted using 2% KCl on five locations within the Caney Shale that consisted of selecting three brittle (reservoir) zones and two ductile zones. Confining pressures ranged from 1,000 psi to 12,000 psi at 210 °F. Conductivity, permeability as well as embedment were measured during the test. Also, an additional, laboratory in-situ visualization test was conducted to examine the detailed proppant-shale matrix interaction under elevated stress (3,920 psi effective stress) and temperature (252 °F), with a synthetic reservoir fluid. Our experimental results have confirmed that improved fracture conductivity is attributed to proppant size, and that the increase in porosity of the proppant pack, closure pressure changes and the reduction in fracture conductivity are a function of many factors such as fracture closure stress.

04 OIL SHALES AND TAR SANDS↗

Design, fabrication, and testing of a water-cooled tungsten-foam high-heat flux plasma-facing module

Here, we present a comprehensive study detailing the design, fabrication and testing a new modular “finger” component, featuring a hexagonal tungsten foam armor tile bonded to the top surface of the water-cooled finger unit. The mechanical, thermal, and particle transport properties of the tungsten foam armor were determined for a wide range of porosity and cell size, and then combined in an equivalent solid material with “effective” properties suitable for large-scale simulations. A series of 3-D multiphysics simulations for coupled thermal and mechanical behavior of the “finger” module are used to optimize the design before fabrication. The simulation results show that, for the expected experimental conditions, a safe range of heat flux and foam porosity is possible for both water-cooling and helium-cooling. Based on these multiphysics simulations, an optimum finger cooling module has been fabricated at Ultramet, Inc. A series of experiments were designed to study the thermomechanical performance of the “finger” unit under steady-state and transient thermal loading at surface heat flux up to 16 MW/m 2 in the High Energy Flux Test facility (HEFTY) at UCLA. Testing conditions included low-power, steady-state plasma exposure at 6 MW/m 2 , followed by severe high heat flux cycles at 16 MW/m 2 . Results of these tests are explained through comparisons with multiphysics simulations. To eliminate the effects of thermomechanical damage carried out on a module on its thermo-mechanical response on a subsequent test, three different yet identically designed and fabricated finger modules were tested. The results show that the current design is capable of cooling the walls of fusion devices at surface heat flux up to 6 MW/m 2 without failure, and that the failure heat flux limit is below 16 MW/m 2 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A helical actuator driven by biased SMA: design, model, and experiment

A helical actuator driven by biased shape memory alloy (SMA) patterns embedded into a soft composite ribbon base is presented in this work. Instead of common U-shape SMA wires, a single SMA wire is woven into planar patterns, which enable helical deformation of the composite ribbon from an initially flat geometry. An analytical static model is established for accurate and rapid prediction of the helical reconfiguration arising from the shape memory effect of woven SMA patterns, followed by validation of the static model using the finite element method (FEM). The finite element results are compared with the analytical solutions given by this static model, which show a high agreement. Parametric study of the influences of eight independent design variables on the dependent helical parameters, such as combined curvatures, pitches, and helical angles, is completed. It is found that the helically deformed geometry is mainly dominated by diameters, biased positions, inclined angles, and numbers of skewed segments of the SMA wire. Fabrication and in-situ experimental test of a prototype of such helical actuators qualitatively demonstrate its dramatic three-dimensional (3D) spiral reconfiguration from a two-dimensional (2D) flat ribbon. In conclusion, such SMA patterns will allow more diverse designs of soft actuators for a wider range of robotic applications.

36 MATERIALS SCIENCE↗

Advanced defrosting techniques in air source heat pumps: A review of vapor injection, thermal energy storage, and experimental frost accumulation data

Electrification is a critical step for reducing greenhouse gas emissions from heating. Air source heat pumps (ASHPs) are a promising alternative to fossil fuel-based systems due to their high coefficients of performance (COP), dual heating and cooling capability, and lower carbon footprint. However, for ASHPs to achieve widespread adoption, they must operate reliably across all climates, including cold regions. Additionally, defrosting techniques should be energy efficient and minimally disruptive to indoor comfort. Vapor injection (VI) technology can address the high-pressure and high-temperature lift challenges encountered in low ambient conditions. More recently, in addition to enhancing heating performance, VI has also been shown to improve the speed and efficiency of reverse cycle defrosting. Likewise, thermal energy storage (TES) has steadily gained attention for its ability to serve as an auxiliary heat source during both normal operation and defrosting. This review analyzes the benefits and limitations of VI- and TES-assisted defrosting approaches. While both technologies show strong potential individually, no studies to date have explored their combined use in ASHP systems. Additionally, to support continued development of defrosting strategies, both in modeling and experimental work, it is critical to establish frost accumulation data under a range of operating conditions. By compiling the available data from the literature, this paper also highlights the limited availability of such experimental data and the wide variation in frosting and defrosting durations and termination criteria, which are often influenced by system design and test setups.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗