Effect of Water Chemistry on Crack Growth Rate in Neutron Irradiated X-750 and XM-19

The Advanced Test Reactor (ATR) National Science User Facility (NSUF) was used to study the effect of neutron damage on crack growth rates (CGR) under simulated boiling water reactor (BWR) water chemistry conditions using a fast neutron spectrum to accelerate the damage process. Nickel based Alloy X-750 and XM-19 were irradiated in the ATR center flux trap (CFT), with this experiment marking the first civilian project to utilize this position within the reactor. 0.4T-CT specimens were used to study crack growth rates for two sample fluences (~1.9 x 1020 n/cm2 and ~9.5 x 1020 n/cm2, E > 1MeV)) in both normal water chemistry (NWC) at 2.5 ppm O2 and hydrogen water chemistry (HWC) at ~80 ppb H2. CGR testing was conducted at a temperature of 288 °C. A decrease in CGR was observed for both alloys with the average ratio (CGR in NWC/CGR in HWC) being a factor of 281 for the XM-19 samples and a factor of 27.8 for the X-750 samples. Observed CGRs in this study showed little difference compared to non-irradiated samples (the non-irradiated XM-19 was 20% cold worked), suggesting limited sensitivity of these susceptible alloys to irradiation effects. Detailed results of CGR response to varying environmental electrochemical potential (ECP) and water purity will be presented in the context of crack growth mitigation in different water chemistries and the change in material behavior relative to non-irradiated samples of the material.

36 MATERIALS SCIENCE↗

Effect of Water Chemistry on Crack Growth Rates in Neutron Irradiated X-750 and XM-19

The Advanced Test Reactor (ATR) National Science User Facility (NSUF) was used to study the effect of neutron damage on crack growth rates (CGR) under simulated boiling water reactor (BWR) water chemistry conditions using a fast neutron spectrum to accelerate the damage process. Nickel based Alloy X-750 and XM-19 were irradiated in the ATR center flux trap (CFT), with this experiment marking the first civilian project to utilize this position within the reactor. 0.4T-CT specimens were used to study crack growth rates for two sample fluences (~1.9 x 1020 n/cm2 and ~9.5 x 1020 n/cm2, E > 1MeV) in both normal water chemistry (NWC) at 2.5 ppm O2 and hydrogen water chemistry (HWC) at ~80 ppb H2. A decrease in CGR was observed with HWC for both alloys with the average ratio (CGR in NWC/CGR in HWC) being a factor of 281 for the XM-19 samples and a factor of 27.8 for the X-750 samples. Observed CGRs in this study showed little difference compared to non-irradiated samples (the non-irradiated XM-19 was 20% cold worked), suggesting limited sensitivity of these susceptible alloys to irradiation effects. The CGR response to varying environmental electrochemical potential (ECP) and water purity will be presented.

36 MATERIALS SCIENCE↗

Consistent Nuclear Data Evaluations for Criticality Safety

Evaluations of nuclear data are based on statistical analysis of available experimental data and their uncertainties plus model calculations and their uncertainties. As the models are currently rather limited, the evaluations are heavily biassed toward experimental data, with the caveat that a thorough analysis is also required to understand possible discrepancies between data sets. Hence, as new experimental data become available, they are incorporated into the evaluation procedure. Recent measurements of the 233 U capture to fission cross section ratio at the Los Alamos Neutron Science Center have prompted a re-evaluation of the capture cross section in the resonance and fast regions up to 250 keV. We will discuss the challenges of including the new fast neutron experimental data in an evaluation that is consistent with the resonance region. We will also discuss our consistent evaluation procedure based on the Hauser-Feshbach statistical model for nuclear reactions and its application to the evaluations of 239 Pu and 139 La neutron-induced reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron elastic and inelastic scattering differential cross sections on carbon

Elastic and inelastic neutron scattering angular distributions were measured on natural carbon samples to confirm existing experimental data and evaluations in the fast neutron region and to guide improvements in resonance parameters, where needed. Sixty-four (n,n') differential cross section measurements were performed at 45 incident neutron energies between 0.5 and 8.0 MeV. Experimental angle-integrated elastic scattering cross sections are consistent with ENDF/B-VIII.0 values with the exception of the region from 3.2 to 4.0 MeV where our results are ~3% higher. In the 3.4 to 3.6 MeV region our differential cross sections are slightly lower at forward angles and somewhat higher at backward angles than the ENDF/B-VIII.0 calculations; however, our results are consistent with measured data from other research groups. The first- through fourth-order elastic scattering Legendre coefficients from fits to these experimental data are consistent with ENDF/B-VIII.0 values across this range of incident neutron energies. Inelastic scattering cross sections were measured at 12 incident neutron energies between 5.6 and 7.8 MeV. Angle-integrated cross sections agree well with the 1978 Perey and ENDF/B-VIII.0 values; however, the angular-distribution shapes deviate somewhat from the ENDF/B-VIII.0 calculations. These data will allow refinement of the resonance parameter description in this difficult energy region.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Oh, My Darling Clementine: A Detailed History and Data Repository of the Los Alamos Plutonium Fast Reactor

The Los Alamos Plutonium Fast Reactor, Clementine, provided the first fast neutron spectrum using a metallic plutonium fuel system and liquid mercury coolant. Clementine is often mentioned in the history of fast, metal-fueled, or metal-cooled designs, with little public information regarding the specifications or timeline. This paper contains a synopsis of each report regarding the development, operation, experimental results, failures, and subsequent disassembly of Clementine to explore this unique reactor within the context of modern advanced reactor development.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparison of measurement and simulation of ATLAS cavern radiation background

Sixteen Medipix2 pixel detector based (MPX) devices were operated at various positions within the ATLAS detector and cavern continuously from early 2008 up to 2013. In addition to photons, each MPX detector is capable to detect charged particles, and neutrons as it is covered with a mask of converter materials dividing its area into regions sensitive to thermal or fast neutrons. The MPX detector network was effectively used for real-time measurements of the spectral characteristics and composition of complex radiation fields in ATLAS. This article reports comparison of the results of measurements performed with MPX detectors during the LHC operation period in 2010 and 2011 with Monte Carlo simulations results from the FLUGG and GCALOR codes. For the purpose of this comparison, the MPX detectors were operated in tracking mode with low threshold (8–10 keV) allowing one to distinguish among particle categories based on the recognition of track patterns left by the particles in the MPX sensitive layer. The comparison of measurements with simulations shows that the agreement between measured and simulated data is satisfactory in most cases within a factor of two.

47 OTHER INSTRUMENTATION↗

Stability analysis of a one-dimensional multiphysics model of a molten salt fast reactor

Reactor designs with a fast neutron spectrum have recently moved into the research focus for possible Generation IV reactor concepts - a representative of which is the molten salt fast reactor (MSFR). In order to assess the safety and reliability of this reactor concept, it is necessary to obtain knowledge of the system behaviour. An important part of this research concerns the dynamical stability of the MSFR. Research regarding the MSFR stability so far has either been using linearized models for stability criteria or only been examining certain transients at fixed parameter values. This work delivers a comprehensive stability analysis for a non-linearized MSFR model, and a wide range of values for all relevant parameters. For this purpose, a one-dimensional MSFR model was set up, taking neutron kinetics and thermal hydraulics in the form of a system of differential equations into account. The stability of this model was investigated by means of the numerical tool MATCONT, which was used to monitor the evolution of a so-called fixed-point solution, here referring to the steady state at operating conditions of the system, while system parameters got varied. The MATCONT analyses showed no loss of stability for any of the considered parameter variations and no solutions that might co-exist in parallel with the steady-state fixed-point solution. Therefore these results indicate a stable fixed point to which all solution transients converge, making the considered MSFR model insusceptible to deviations from the equilibrium. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Demonstration of active neutron interrogation of special nuclear materials using a high-intensity short-pulse-laser-driven neutron source

Detecting shielded special nuclear material, such as nuclear explosives, is a difficult challenge pursued by non-proliferation, anti-terrorism, and nuclear security programs worldwide. Interrogation with intense fast-neutron pulses is a promising method to characterize concealed nuclear material rapidly but is limited by suitable source availability and proven instrumentation. In this study we have pioneered a demonstration of such an interrogation method using a high-intensity, short-pulse, laser-driven neutron source that offers potential benefits compared to conventional neutron sources. The measurement results reported here represent the first experimental demonstration of this interrogation approach on enriched uranium items and demonstrate the feasibility of a precise measurement using realistic nuclear materials, representative of field scenarios, even with just a single laser-driven neutron pulse. Bright pulsed sources can overcome the nuisance background of items with strong internal neutron sources, improving analytical power, while single-shot assay is attractive in high-throughput situations where time is at a premium. The science and technology of this type of neutron production is developing rapidly, and we anticipate that practical mobile interrogation systems will become available based on the detection concepts demonstrated here to meet the growing measurement needs.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Subcritical Neutron and Gamma Noise Measurements at the Seven Percent Critical Experiment (7uPCX) [Slides]

Post measurement synchronization of noise signals allowed for the investigation of previously unseen correlations. Noise of gamma, thermal and fast neutron signals performed similarly in estimating the prompt neutron decay constant at various subcritical states. The CPSD amplitude terms displayed different magnitudes. The neutron-based amplitudes suffered more from changes in detector efficiency as the number of fuel rods in the system increased. The time lag between 3 He tubes is observable using the CPSD phase angle and agreed with a simplified diffusion estimation.

3He detectors↗

Characterization of stilbene-d 12 for neutron spectroscopy without time of flight

In this work, we have experimentally characterized the light-output response of a deuterated trans-stilbene (stilbene-d 12 ) crystal to quasi-monoenergetic neutrons in the 0.8 to 4.4 MeV energy range. These data allowed us to perform neutron spectroscopy measurements of a DT 14.1 MeV source and a 239 PuBe source by unfolding the impinging neutron spectrum from the measured light-output response. The stilbene-d 12 outperforms a 1 H-stilbene of similar size when comparing the shape of the unfolded spectra and the reference ones. These results confirm the viability of non-hygroscopic stilbene-d 12 crystal for direct neutron spectroscopy without need for time-of-flight measurements. This capability makes stilbene-d 12 a well suited detector for fast-neutron spectroscopy in many applications including nuclear reaction studies, radiation protection, nuclear non-proliferation, and space travel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prompt Photofission Neutron Detection in Depleted Uranium

The detection of prompt photofission neutrons during active interrogation is a strong indication of the presence of special nuclear materials. However, the high-energy photons used for interrogation create a very challenging radiation environment for the detection of prompt fission signatures. These challenges include detector saturation and pulse pile-up. Additionally, there is an elevated neutron background that further challenges the detection of prompt fission neutrons. This background is produced because of (γ, Xn) photonuclear reactions in the surrounding high-Z materials. Here, we demonstrate the detection of prompt photofission neutrons in these challenging environments. Depleted uranium (DU) and lead targets are interrogated with bremsstrahlung photons produced by a 9-MV electron linear accelerator. Fast neutrons are detected with trans-stilbene organic detectors, and scintillation pulses are analyzed using a previously developed and demonstrated artificial neural network system. We observe a 5 times higher photoneutron count rate when the lead target is replaced with the DU target. Additionally, we observe a difference in the photoneutron light-output distributions of lead and DU. Here, this difference in the measured distributions is due to the difference in the photoneutron-energy spectra; DU photoneutrons are emitted with (γ, n) and watt-energy spectra, whereas lead photoneutrons are emitted with only the (γ, n) spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

AGR-3/4 TRISO Fuel Compact Ceramography

The combined third and fourth irradiation in the Advanced Gas Reactor (AGR) program (AGR-3/4) contained tristructural isotropic (TRISO)-coated particle fuel and designed-to-fail (DTF) fuel particles. The DTF particles were only coated with highly anisotropic pyrocarbon (PyC) so they would purposely fail during the AGR-3/4 irradiation and provide a source of fission products for measurement. To observe the post-irradiation morphology of these DTF particles and the TRISO-coated particles, three AGR-3/4 compacts were mounted in epoxy, sectioned above their centerlines, and ground/polished. Three rounds of grinding/polishing and optical microscopy were performed so that the particles could be observed at multiple planes. Each compact contained approximately 1,872 TRISO particles and exactly 20 DTF particles. The three AGR-3/4 compacts examined covered a wide temperature range and featured both the hottest average irradiation temperature (1375°C) and the coldest/lowest burnup (872°C and 5.5% fissions per initial metal atom) of any compacts to undergo post-irradiation examination (PIE) in the AGR program to date. A total of 29 DTF particles were located and observed via microscopy across the three compacts. All the DTF particles observed via microscopy had completely failed PyC coatings. Some different DTF kernel and PyC morphologies were observed that have been attributed to the differences in irradiation temperature and/or burnup. At low and medium irradiation temperatures (roughly 850 to 1050°C), it appears irradiation-induced dimensional changes in the DTF PyC caused it to fracture and fold in on itself, and the kernel deformed to accommodate this PyC deformation. The extent of DTF kernel deformation to accommodate DTF PyC buckling tended to be greater for the medium-temperature fuel compared to the cold fuel. In the high-irradiation-temperature compact (1375°C), the DTF PyC layer appears to have completely reacted chemically with the kernel material. The only material surrounding the DTF particles in this hot compact resembles the compact matrix material. Observations of the TRISO-coated driver fuel particles and fuel compact graphitic matrix were also made. The TRISO particle kernels in the medium-temperature compact (1047°C), and many in the high-temperature compact (1375°C), showed morphologies consistent with what was seen in AGR-1 and AGR-2. In other TRISO particles from the high-temperature compact, a spatial gradient in the kernel appearance was evident. Here the cool side of the kernel (away from the center of the compact) had a much darker appearance (like that of the buffer and pyrocarbon). This is the first observation of this kind of kernel spatial gradient in AGR fuel. It is believed that the high irradiation temperature of that compact (an average of 1375°C) activates or accelerates an unidentified chemical reaction, and the temperature gradient within the fuel causes a sharp spatial gradient. The low-temperature/low-burnup compact also showed unique kernel morphologies where the TRISO-coated particles had clearly distinguishable oxide and carbide phases at the center of the kernel, an oxide rind surrounding this, and remnants of a carbide skin surrounding the oxide rind. These are features observed in the as-fabricated fuel that are no longer present in higher burnup fuel. Occasional gaps between the outer pyrolytic carbon (OPyC) and graphitic matrix material were observed in all compacts. Gaps were most often found in the small, matrix-filled spaces between adjacent particles. Finally, buffer morphologies in AGR-3/4 TRISO particles were like those observed in AGR-1 and AGR-2, and the buffer fracture frequencies in AGR-3/4 and AGR-2 TRISO particles were plotted versus fast neutron fluence and irradiation temperature. In AGR-3/4 the buffer fracture rate was highest (23%) for an irradiation temperature of 1047°C and a fast fluence of 5.18E25 n/m 2 . Increasing the irradiation temperature to 1375°C reduced the buffer fracture rate to 14%. Reducing the irradiation temperature to 872°C and the fast fluence by a factor of 3 reduced the buffer fracture rate to 7%. The temperature and fluence dependencies observed for AGR-3/4 buffer fracture were consistent with those observed in AGR-2. Lower fluences and/or higher temperatures significantly reduced the buffer fracture frequencies. Lower buffer fracture frequencies were also observed at lower temperatures as long as the fluence was also significantly reduced. This is believed to be due to lower fluence resulting in less irradiation-induced dimensional change (shrinkage) of the buffer, and a higher temperature promoting enhanced creep relaxation of stresses within the buffer, leading to less buffer fracture.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Testing fast reactor fuels in a thermal reactor: Comparison of transmutation metallic fuel alloys behavior by scanning electron microscopy

To optimize nuclear waste repository performance, the destruction of minor actinide elements, particularly Np and Am, in a neutron fast spectrum reactor is possible by incorporating these elements into nuclear fuel. Evaluating the performance of minor actinide containing fuel is of paramount importance to enabling this technology. However, such a task is challenging without an available domestic fast spectrum test reactor. A comparison of fuel performance tested in an available domestic thermal reactor at the Idaho National Laboratory, the Advanced Test Reactor, and in a fast spectrum reactor in France (Phénix) is presented here in this study. This study evaluates the capability of using a cadmium shrouded test position to mimic the power profile along the fuel radius present in fast spectrum reactors so that thermally driven phenomenon (e.g., constituent redistribution) can be evaluated in a thermal reactor and determined to be prototypical of a fast reactor. Thus, optical microscopy and scanning electron microscopy has been performed on irradiated 35U-29Pu-4Am-2Np-30Zr fuel samples (where the number preceding the element is the weight percent concentration) from the two mentioned reactors that present similar irradiation temperatures and power conditions. The results indicate that fuel performance phenomena are reproducible in the two irradiation conditions. The redistribution of Zr occurred in the same manner for the two samples. Similar partitioning of U-Pu-Zr phases was observed, and the behavior of Am was similar in the analyzed specimens. Finally, the overall microstructure evolution seems not to be affected by minor actinides addition compared to expected behavior of conventional U-19Pu-10Zr ternary metal fuels for both specimens. Slight differences in fuel cladding chemical interaction were, however, observed. This difference is likely driven by difference in cladding composition rather than irradiation conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Irradiation Results of Commercial Neutron and Gamma Sensors at the Ohio State University Research Reactor

This report serves to present the evaluation results of commercial radiation detectors (SPNDs) with the potential to accomplish the data objectives—having sufficient gamma and fast neutron sensitivity—at temperatures near 650°C. The detectors chosen for evaluation are gamma ion chambers from Exosens (previously known as Photonis) models CRGA11 and CRGE32 and tantalum-based self-powered neutron detectors (Ta-SPND) from Mirion. The evaluation was performed in a series of heat irradiations from ambient to 850°C in the 9.5-inch dry tube furnace at the Ohio State University Research Reactor (OSURR). Ion chamber counting curves were measured to evaluate sensor operability at temperature. Detector sensitivity to reactor power and temperature were measured and presented in curve fit parameters. The curve fit equations were used to identify the suggested operational temperatures based on reactor power. Overall, it was evaluated that the CRGA11 was not significantly affected by temperatures up to 650°C and is operable—with higher temperature-contributed signals—up to 700°C. The CRGE32 was more affected by the high temperatures compared to the CRGA11. As a result of increasing temperature, the leakage current was a dominating factor. While the detector can operate up to 600°C and 700°C with lowered high voltage, it is not recommended unless a suitably strong gamma flux field is present. Finally, Ta SPND did not demonstrate good performance beyond 350°C due to the presence of an unknown phenomenon at changing temperatures. The study of the phenomenon is an active research topic outside the scope of this project.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Application of the Cohn-alpha Method on Bare Highly Enriched Uranium Using Organic Scintillators [Poster]

The prompt neutron decay constant (α), can be used to calculate the lifetime of prompt fission chains within a multiplying system and verify reactor startup and shutdown. We analyze a fast, bare system consisting of highly enriched uranium (93% 235 U) hemisphere shells known as the Measurements of Uranium Subcritical and Critical (MUSiC). We measured the system with a three by-four array of organic scintillators (OSCAR) to obtain the gamma-ray and fast neutron signals. Pulse shape discrimination was used to isolate the neutron time series data. The Cohn-α method was used to estimate α for 3 supercritical measurements of Configurations 8 MUSiC. We use these estimates to linearly extrapolate α at delayed critical. These values can be compared to highly detailed simulations in MCNP6.2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of cosmogenic production of 39 Ar and 42 Ar for rare-event physics using underground argon

Underground argon (UAr) with lower cosmogenic activities of 39 Ar and 42 Ar has been planned as a detector in detecting scintillation light and charge collection using time projection chambers for dark matter searches and as a veto detector in suppressing backgrounds for neutrinoless double beta decay (0$vββ$ ) experiments. Long-lived radioactive isotopes, 39 Ar and 42 Ar, can also be produced on the surface when UAr is pumped out from a deep well. Understanding the production of long-lived isotopes in Ar is important for utilizing UAr for dark matter and 0$vββ$ experiments in terms of its production, transportation, and storage. Ar exposure to cosmic rays at sea-level is simulated using Geant4 for a given cosmic ray muon, neutron, and proton energy spectrum. Here we report the simulated cosmogenic production rates of 39 Ar, 42 Ar, and other long-lived isotopes at sea-level from fast neutrons, high energy muons, and high energy protons. Total production rates of 938.53/kg Ar day and 5.81 × 10 -3 /kg Ar day for 39 Ar and 42 Ar are found from our simulation. Utilizing these production rates, we set a time limit of 954 days constrained by the production of 39 Ar for UAr to be on the surface before it compromises the sensitivity for a dark matter experiment. Similarly, a time limit of 1702 days constrained by the production of 42 Ar is found for a 0$vββ$ experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ECAR-1406 AS-RUN NEUTRONIC ANALYSIS OF THE AGC-1 EXPERIMENT IRRADIATED IN THE ATR SOUTH FLUX TRAP

This Engineering Calculations Analysis Report (ECAR) documents the results of the Advanced Test Reactor (ATR) detailed physics analyses performed to calculate the displacements per atom (DPA) and the fast neutron fluence (E > 0.1 MeV) of the Advanced Graphite Creep (AGC) experiment, AGC-1, irradiated in the ATR South Flux Trap (SFT) (see Figure 1) during ATR Cycle 145A, Cycle 145B, Cycle 146A, Cycle 146B, Cycle 147A, Cycle 148A and Cycle 148B. The results for these evaluations and analysis are reported herein.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

GENESIS: Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering

Improved neutron inelastic scattering cross section data are needed to inform integral benchmark studies and advance applications in a wide variety of areas including nuclear energy, stockpile stewardship, nonproliferation, and space exploration. Neutron inelastic scattering also serves as a non-selective probe of low-lying nuclear structure. To help meet these needs, the Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) was constructed at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. This array couples high-resolution γ-ray detectors and fast neutron detectors to achieve single and coincident n/γ detection over a broad energy range. The current configuration of the array includes 26 organic liquid scintillators and four high-purity germanium detectors (two single-crystal and two four-crystal CLOVER detectors with two-fold segmentation). The array was constructed with minimal supporting material and designed to cover a wide range of secondary particle angles and energies with limited inter-element scattering. Data acquisition is accomplished using Mesytec MDPP-16 multi-channel high-resolution digital pulse processing modules. The array characteristics, including γ-ray and neutron energy resolution, timing resolution, and detection efficiency were measured and used to validate a Geant4 model of the array. Furthermore, the primary sources of neutron background and the uncertainties in the determination of incident and secondary neutron energy were assessed. GENESIS provides a new capability to address nuclear data needs and facilitates the advancement of a wide range of nuclear applications.