Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUORESCENCE MICROSCOPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Understanding Molecular Interactions within Chemically Selective Layered Polymer Assemblies

This work focuses on two broad issues. These are (1) the molecular origin of the chemical selectivity achieved with ultrathin polymer multilayers, and (2) how the viscoelastic properties of the polymer layers are affected by exposure to solvent and analytes. These issues are inter-related, and to understand them we need to design experiments that probe both the energetic and kinetic aspects of interfacial adsorption processes. This project focuses on controling the chemical structure, thickness, morphology and sequential ordering of polymer layers bound to interfaces using maleimide-vinyl ether and closely related alternating copolymerization chemistry and efficient covalent cross-linking reactions that allow for layer-by-layer polymer deposition. This chemistry has been developed during the funding cycle of this Grant. We have measure the equilibrium constants for interactions between specific layers within the polymer interfaces and size-controlled, surface-functionalized gold nanoparticles. The ability to control both size and functionality of gold nanoparticle model analytes allows us to evaluate the average “pore size” that characterizes our polymer films. We have measured the “bulk” viscosity and shear modulus of the ultrathin polymer films as a function of solvent overlayer identity using quartz crystal microbalance complex impedance measurements. We have measured microscopic viscosity at specific locations within the layered polymer interfaces with time-resolved fluorescence lifetime and depolarization techniques. We combine polymer, cross-linking and nanoparticle synthetic expertise with a host of characterization techniques, including QCM gravimetry and complex impedance analysis, steady state and time-resolved spectroscopies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorescence Microscopy Denoising (FMD) dataset

We created a dataset - the Fluorescence Microscopy Denoising (FMD) dataset - that is dedicated to Poisson-Gaussian denoising. The dataset consists of 12,000 real fluorescence microscopy images obtained with commercial confocal, two-photon, and wide-field microscopes and representative biological samples such as BPAE cells, zebrafish, and mouse brain tissues. We use image averaging to effectively obtain ground truth images and 60,000 noisy images with different noise levels.

Image Denoising↗

Micro and Nano Systems for Space Exploration

This slide presentation reviews the use of micro and nano systems in Space exploration. Included are: an explanation of the rationales behind nano and micro technologies for space exploration, a review of how the devices are fabricated, including details on lithography with more information on Electron Beam (E-Beam) lithography, and X-ray lithography, a review of micro gyroscopes and inchworm Microactuator as examples of the use of MicroElectoMechanical (MEMS) technology. Also included is information on Carbon Nanotubes, including a review of the CVD growth process. These micro-nano systems have given rise to the next generation of miniature X-ray Diffraction, X-ray Fluorescence instruments, mass spectrometers, and terahertz frequency vacuum tube oscillators and amplifiers, scanning electron microscopes and energy dispersive x-ray spectroscope. The nanotechnology has also given rise to coating technology, such as silicon nanotip anti-reflection coating.

carbon nanotubes↗

Development of an Autofluorescence Spectral Database for the Identification and Classification of Microbial Extremophiles

Extremophiles are microorganisms that have adapted to severe conditions that were once considered devoid of life. The extreme settings in which these organisms flourish on earth resemble many extraterrestrial environments. Identification and classification of extremophiles in situ (without the requirement for excessive handling and processing) can provide a basis for designing remotely operated instruments for extraterrestrial life exploration. An important consideration when designing such experiments is to prevent contamination of the environments. We are developing a reference spectral database of autofluorescence from microbial extremophiles using long-UV excitation (405 nm). Aromatic compounds are essential components of living systems, and biological molecules such as aromatic amino acids, nucleotides, porphyrins and vitamins can also exhibit fluorescence under long-UV excitation conditions. Autofluorescence spectra were obtained from a confocal microscope that additionally allowed observations of microbial geometry and motility. It was observed that all extremophiles studied displayed an autofluorescence peak at around 470 nm, followed by a long decay that was species specific. The autofluorescence database can potentially be used as a reference to identify and classify past or present microbial life in our solar system.

Sabanayagam, Chandran↗

Dissection of the angle of single fluorophore attached to the nucleotide in corkscrewing microtubules

Direct dissection of the angles of single fluorophores under an optical microscope has been a challenging approach to study the dynamics of proteins in an aqueous solution. For angle quantifications of single substrates, however, there was only one report (Nishizaka et al., 2014) because of difficulties of construction of experimental systems with active proteins working at the single-molecule level. We here show precise estimation of orientation of single fluorescent nucleotides bound to single tubulins that comprise microtubule. When single-headed kinesins immobilized on a glass surface drive the sliding of microtubules, microtubules show corkscrewing with regular pitches (Yajima et al., 2005 & 2008). We found, by using a three-dimensional tracking microscope, that S8A mutant kinesin also showed precise corkscrewing with a 330-nm pitch, which is 13% longer than that of the wild type. The assay with the mutant was combined with a defocused imaging technique to visualize the rotational behavior of fluorescent nucleotide bound to corkscrewing microtubule. Notably, the defocused pattern of single TAMRA-GTP periodically changed, precisely correlating to its precession movement. The time course of the change in the fluorophore angle projected to the xy-plane enabled to estimate both the fluorophore orientation against microtubule axis and the precision of angle-determination of analyses system. The orientation showed main distribution with peaks at∼40°, 50° and 60°. To identify their molecular conformations, the rigorous docking simulations were performed using an atomic-level structure modeled by fitting x-ray crystal structures to the cryo-electron microscopy map. Among isomers, 2′-O-EDA-GDP labeled with 5- or 6-TAMRA were mainly specified as possible candidates as a substrate, which suggested the hydrolysis of TAMRA-GTP by tubulins. - Highlights: • The mutant of single-headed kinesin drives the corkscrewing of microtubules with a longer pitch. • Orientation of single fluorescent GTP on rotating microtubule was measured by defocused imaging. • The orientation showed the distribution with peaks at∼40°, 50° and 60° against microtubule axis. • Docking simulation reveals possible molecular conformations and state of nucleotide on tubulin.

60 APPLIED LIFE SCIENCES↗

A new green phosphor of SrAl{sub 2}O{sub 4}:Eu{sup 2+},Ce{sup 3+},Li{sup +} for alternating current driven light-emitting diodes

Graphical abstract: Display Omitted Highlights: ► This work focuses on exploring new phosphors of SrAl{sub 2}O{sub 4}:Eu{sup 2+},Ce{sup 3+},Li{sup +} for AC LEDs. ► The work provides a new route to synthesize the pure phase of SrAl{sub 2}O{sub 4}. ► The formation of the impurity phase of Sr{sub 4}Al{sub 14}O{sub 25} was suppressed by using Ce{sup 3+}. ► Charger defects were compensated by using Li{sup +}. ► The luminescence intensity was enhanced significantly by co-doping Ce{sup 3+} and Li{sup +}. -- Abstract: New phosphors are desired to overcoming the flickering luminescence of alternating current light-emitting diodes (AC-LEDs) by compensating dark duration with appropriately persistent luminescence. Here, the phosphor of SrAl{sub 2}O{sub 4}:Eu{sup 2+},Ce{sup 3+},Li{sup +} was developed for this application. The phosphor was synthesized with solid-state reaction method by using H{sub 3}BO{sub 3} as flux. The XRD patterns show that the impurity phase of Sr{sub 4}Al{sub 14}O{sub 25} which always formed together with SrAl{sub 2}O{sub 4} during reaction was suppressed by using Ce. The charger defects caused by the non-equivalent substitution of Sr{sup 2+} with Ce{sup 3+} were compensated with Li{sup +}. Thus, the luminescence intensity of SrAl{sub 2}O{sub 4}:Eu{sup 2+} was enhanced significantly by co-doping Ce{sup 3+} and Li{sup +}. The fluorescence lifetime of the phosphor is about 36.5 ms. The energy dispersive spectra (EDS) assisted with scanning electron microscope (SEM) pictures reveal that Ce ions mainly distribute along grain boundary.

36 MATERIALS SCIENCE↗

Supercontinuum Stimulated Emission Depletion Fluorescence Lifetime Imaging

Supercontinuum (SC) stimulated emission depletion (STED) fluorescence lifetime imaging is demonstrated by using time-correlated single-photon counting (TCSPC) detection. The spatial resolution of the developed STED instrument was measured by imaging monodispersed 40-nm fluorescent beads and then determining their fwhm, and was 36 ± 9 and 40 ± 10 nm in the X and Y coordinates, respectively. The same beads measured by confocal microscopy were 450 ± 50 and 430 ± 30 nm, which is larger than the diffraction limit of light due to underfilling the microscope objective. Underfilling the objective and time gating the signal were necessary to achieve the stated STED spatial resolution. The same fluorescence lifetime (2.0 ± 0.1 ns) was measured for the fluorescent beads by using confocal or STED lifetime imaging. The instrument has been applied to study Alexa Fluor 594-phalloidin labeled F-actin-rich projections with dimensions smaller than the diffraction limit of light in cultured cells. Fluorescence lifetimes of the actin-rich projections range from 2.2 to 2.9 ns as measured by STED lifetime imaging.

36 MATERIALS SCIENCE↗

Low axial drift stage and temperature controlled liquid cell for z-scan fluorescence correlation spectroscopy in an inverted confocal geometry

A recent iteration of fluorescence correlation spectroscopy (FCS), z-scan FCS, has drawn attention for its elegant solution to the problem of quantitative sample positioning when investigating two-dimensional systems while simultaneously providing an excellent method for extracting calibration-free diffusion coefficients. Unfortunately, the measurement of planar systems using (FCS and) z-scan FCS still requires extremely mechanically stable sample positioning, relative to a microscope objective. As axial sample position serves as the inherent length calibration, instabilities in sample position will affect measured diffusion coefficients. Here, we detail the design and function of a highly stable and mechanically simple inverted microscope stage that includes a temperature controlled liquid cell. The stage and sample cell are ideally suited to planar membrane investigations, but generally amenable to any quantitative microscopy that requires low drift and excellent axial and lateral stability. In the present work we evaluate the performance of our custom stage system and compare it with the stock microscope stage and typical sample sealing and holding methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multispecies Biofilms Transform Selenium Oxyanions into Elemental Selenium Particles: Studies Using Combined Synchrotron X-ray Fluorescence Imaging and Scanning Transmission X-ray Microscopy

Selenium (Se) is an element of growing environmental concern, because low aqueous concentrations can lead to biomagnification through the aquatic food web. Biofilms, naturally occurring microbial consortia, play numerous important roles in the environment, especially in biogeochemical cycling of toxic elements in aquatic systems. The complexity of naturally forming multispecies biofilms presents challenges for characterization because conventional microscopic techniques require chemical and physical modifications of the sample. Here, multispecies biofilms biotransforming selenium oxyanions were characterized using X-ray fluorescence imaging (XFI) and scanning transmission X-ray microscopy (STXM). These complementary synchrotron techniques required minimal sample preparation and were applied correlatively to the same biofilm areas. Sub-micrometer XFI showed distributions of Se and endogenous metals, while Se K-edge X-ray absorption spectroscopy indicated the presence of elemental Se (Se0). Nanoscale carbon K-edge STXM revealed the distributions of microbial cells, extracellular polymeric substances (EPS), and lipids using the protein, saccharide, and lipid signatures, respectively, together with highly localized Se0 using the Se LIII edge. Transmission electron microscopy showed the electron-dense particle diameter to be 50–700 nm, suggesting Se0 nanoparticles. The intimate association of Se0 particles with protein and polysaccharide biofilm components has implications for the bioavailability of selenium in the environment.

Yang, Soo In↗

Complete polarization of electronic spins in OLEDs

At low temperatures and high magnetic fields, electron and hole spins in an organic light-emitting diode become polarized so that recombination preferentially forms molecular triplet excited-state species. For low device currents, magnetoelectroluminescence perfectly follows Boltzmann activation, implying a virtually complete polarization outcome. As the current increases, the magnetoelectroluminescence effect is reduced because spin polarization is suppressed by the reduction in carrier residence time within the device. Under these conditions, an additional field-dependent process affecting the spin-dependent recombination emerges, possibly related to the build-up of triplet excitons and their interaction with free charge carriers. Suppression of the EL alone does not prove electronic spin polarization. We therefore probe changes in the spin statistics of recombination directly in a dual singlet-triplet emitting material, which shows a concomitant rise in phosphorescence intensity as fluorescence is suppressed. Finite spin-orbit coupling in these materials gives rise to a microscopic distribution in effective g-factors of electrons and holes, Δg, i.e., a distribution in Larmor frequencies. This Δg effect in the pair, which mixes singlet and triplet, further suppresses singlet-exciton formation at high fields in addition to thermal spin polarization of the individual carriers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Standalone interferometry-based calibration of convex lens-induced confinement microscopy with nanoscale accuracy

Strongly confined environments (confined dimensions between 1–100 nm) represent unique challenges and opportunities for understanding and manipulating molecular behavior due to the significant effects of electric double layers, high surface-area to volume ratios, and other phenomena at the nanoscale. Convex Lens-induced Confinement (CLiC) can be used to analyze the dynamics of individual molecules or particles confined in a planar slit geometry with continuously varying gap thickness. Here, we describe an interferometry-based method for precise measurement of the slit pore geometry. Specifically, this approach permitted accurate characterization of separation distances as small as 5 nm, with 1 nm precision, without a priori knowledge or assumptions about the contact geometry, as well as a greatly simplified experimental setup that required only a lens, coverslip, and inverted microscope. The interferometry-based measurement of gap height offered a distinct advantage over conventional fluorescent dye-based methods; e.g., accurate interferometric height measurements were made at low gap heights regardless of solution conditions, while the concentration of fluorescent dye was significantly impacted by solution conditions such as ionic strength or pH. The accuracy of the interferometric measurements was demonstrated by comparing the experimentally measured concentration of a charged fluorescent dye as a function of gap thickness with dye concentration profiles calculated using Debye–Hückel theory. Accurate characterization of nanoscale gap thickness will enable researchers to study a variety of practical and biologically relevant systems within the CLiC geometry.

42 ENGINEERING↗

Coherent Anti-Stokes Raman Scattering Spectroscopy of Single Molecules in Solution

During this funding period, we have developed two breakthrough techniques. The first is stimulated Raman scattering microscopy, providing label-free chemical contrast for chemical and biomedical imaging based on vibrational spectroscopy. Spontaneous Raman microscopy provides specific vibrational signatures of chemical bonds, but is often hindered by low sensitivity. We developed a three-dimensional multiphoton vibrational imaging technique based on stimulated Raman scattering (SRS). The sensitivity of SRS imaging is significantly greater than that of spontaneous Raman microscopy, which is achieved by implementing high-frequency (megahertz) phase-sensitive detection. SRS microscopy has a major advantage over previous coherent Raman techniques in that it offers background-free and readily interpretable chemical contrast. We demonstrated a variety of biomedical applications, such as differentiating distributions of omega-3 fatty acids and saturated lipids in living cells, imaging of brain and skin tissues based on intrinsic lipid contrast, and monitoring drug delivery through the epidermis. This technology offers exciting prospect for medical imaging. The second technology we developed is stimulated emission microscopy. Many chromophores, such as haemoglobin and cytochromes, absorb but have undetectable fluorescence because the spontaneous emission is dominated by their fast non-radiative decay. Yet the detection of their absorption is difficult under a microscope. We use stimulated emission, which competes effectively with the nonradiative decay, to make the chromophores detectable, as a new contrast mechanism for optical microscopy. We demonstrate a variety of applications of stimulated emission microscopy, such as visualizing chromoproteins, non-fluorescent variants of the green fluorescent protein, monitoring lacZ gene expression with a chromogenic reporter, mapping transdermal drug distributions without histological sectioning, and label-free microvascular imaging based on endogenous contrast of haemoglobin. For all these applications, sensitivity is orders of magnitude higher than for spontaneous emission or absorption contrast, permitting nonfluorescent reporters for molecular imaging. Although we did not accomplish the original goal of detecting single-molecule by CARS, our quest for high sensitivity of nonlinear optical microscopy paid off in providing the two brand new enabling technologies. Both techniques were greatly benefited from the use of high frequency modulation for microscopy, which led to orders of magnitude increase in sensitivity. Extensive efforts have been made on optics and electronics to accomplish these breakthroughs.

47 OTHER INSTRUMENTATION↗

Imaging Primary Mouse Sarcomas After Radiation Therapy Using Cathepsin-Activatable Fluorescent Imaging Agents

Purpose: Cathepsin-activated fluorescent probes can detect tumors in mice and in canine patients. We previously showed that these probes can detect microscopic residual sarcoma in the tumor bed of mice during gross total resection. Many patients with soft tissue sarcoma (STS) and other tumors undergo radiation therapy (RT) before surgery. This study assesses the effect of RT on the ability of cathepsin-activated probes to differentiate between normal and cancerous tissue. Methods and Materials: A genetically engineered mouse model of STS was used to generate primary hind limb sarcomas that were treated with hypofractionated RT. Mice were injected intravenously with cathepsin-activated fluorescent probes, and various tissues, including the tumor, were imaged using a hand-held imaging device. Resected tumor and normal muscle samples were harvested to assess cathepsin expression by Western blot. Uptake of activated probe was analyzed by flow cytometry and confocal microscopy. Parallel in vitro studies using mouse sarcoma cells were performed. Results: RT of primary STS in mice and mouse sarcoma cell lines caused no change in probe activation or cathepsin protease expression. Increasing radiation dose resulted in an upward trend in probe activation. Flow cytometry and immunofluorescence showed that a substantial proportion of probe-labeled cells were CD11b-positive tumor-associated immune cells. Conclusions: In this primary murine model of STS, RT did not affect the ability of cathepsin-activated probes to differentiate between tumor and normal muscle. Cathepsin-activated probes labeled tumor cells and tumor-associated macrophages. Our results suggest that it would be feasible to include patients who have received preoperative RT in clinical studies evaluating cathepsin-activated imaging probes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tapered fiber coupling of single photons emitted by a deterministically positioned single nitrogen vacancy center

A diamond nano-crystal hosting a single nitrogen vacancy (NV) center is optically selected with a confocal scanning microscope and positioned deterministically onto the subwavelength-diameter waist of a tapered optical fiber (TOF) with the help of an atomic force microscope. Based on this nano-manipulation technique, we experimentally demonstrate the evanescent coupling of single fluorescence photons emitted by a single NV-center to the guided mode of the TOF. By comparing photon count rates of the fiber-guided and the free-space modes and with the help of numerical finite-difference time domain simulations, we determine a lower and upper bound for the coupling efficiency of (9.5 ± 0.6)% and (10.4 ± 0.7)%, respectively. Our results are a promising starting point for future integration of single photon sources into photonic quantum networks and applications in quantum information science.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Molecular-scale measurements of electric fields at electrochemical interfaces.

Spatially resolved measurements of electric fields at electrochemical interfaces would be a critical step toward further understanding and modeling the detailed structure of electric double layers. The goal of this project was to perform proof-of-principle experiments to demonstrate the use of field-sensitive dyes for optical measurements of fields in electrochemical systems. A confocal microscope was developed that provides sensitive detection of the lifetime and high resolution spectra of excited fluorescence for dyes tethered to electrically conductive surfaces. Excited state lifetimes for the dyes were measured and found to be relatively unquenched when linked to indium tin oxide, but strongly quenched on gold surfaces. However, our fluorescence detection is sufficiently sensitive to measure spectra of submonolayer dye coatings even when the fluorescence was strongly quenched. Further work to create dye labeled interfaces on flat, uniform and durable substrates is necessary to make electric field measurements at interfaces using field sensitive dyes.

47 OTHER INSTRUMENTATION↗

Cellular response to high pulse repetition rate nanosecond pulses varies with fluorescent marker identity

Nanosecond electric pulses (nsEP's) are a well-studied phenomena in biophysics that cause substantial alterations to cellular membrane dynamics, internal biochemistry, and cytoskeletal structure, and induce apoptotic and necrotic cell death. While several studies have attempted to measure the effects of multiple nanosecond pulses, the effect of pulse repetition rate (PRR) has received little attention, especially at frequencies greater than 100 Hz. In this study, uptake of Propidium Iodide, FM 1–43, and YO-PRO-1 fluorescent dyes in CHO-K1 cells was monitored across a wide range of PRRs (5 Hz–500 KHz) using a laser-scanning confocal microscope in order to better understand how high frequency repetition rates impact induced biophysical changes. We show that frequency trends depend on the identity of the dye under study, which could implicate transmembrane protein channels in the uptake response due to their chemical selectivity. Finally, YO-PRO-1 fluorescence was monitored in the presence of Gadolinium (Gd{sup 3+}), Ruthenium Red, and in calcium-free solution to elucidate a mechanism for its unique frequency trend. - Highlights: • Pulse repetition rate (PRR) is understudied in nanosecond electric pulsing. • 200 V pulses were applied to CHO-K1 cells from 5 Hz to 500 KHz. • Pulsing was repeated using a variety of fluorophores and imaging conditions. • The response is highly dependent on the fluorophore and the imaging conditions. • This may implicate protein channels in the nanoporation response.

60 APPLIED LIFE SCIENCES↗

Characterization and Application of a Hybrid Optical Microscopy/Laser Ablation Liquid Vortex Capture/Electrospray Ionization System for Mass Spectrometry Imaging with Sub-micrometer Spatial Resolution

Herein, a commercial optical microscope, laser microdissection instrument was coupled with an electrospray ionization mass spectrometer via a low profile liquid vortex capture probe to yield a hybrid optical microscopy/mass spectrometry imaging system. The instrument has bright-field and fluorescence microscopy capabilities in addition to a highly focused UV laser beam that is utilized for laser ablation of samples. With this system, material laser ablated from a sample using the microscope was caught by a liquid vortex capture probe and transported in solution for analysis by electrospray ionization mass spectrometry. Both lane scanning and spot sampling mass spectral imaging modes were used. The smallest area the system was able to ablate was ~0.544 μm × ~0.544 μm, achieved by oversampling of the smallest laser ablation spot size that could be obtained (~1.9 μm). With use of a model photoresist surface, known features as small as ~1.5 μm were resolved. The capabilities of the system with real world samples were demonstrated first with a blended polymer thin film containing poly(2-vinylpyridine) and poly(N-vinylcarbazole). Using spot sampling imaging, sub-micrometer sized features (0.62, 0.86, and 0.98 μm) visible by optical microscopy were clearly distinguished in the mass spectral images. A second real world example showed the imaging of trace amounts of cocaine in mouse brain thin tissue sections. Lastly, with use of a lane scanning mode with ~6 μm × ~6 μm data pixels, features in the tissue as small as 15 μm in size could be distinguished in both the mass spectral and optical images.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis of belite cement clinker of high hydraulic reactivity

This study is concerned with the increase of the cooling rate of belite clinker, by using the water quenching for the chemical stabilization of reactive belite, which improves the hydraulic properties of this clinker. The addition of adequate mineralizers, as NaF and Fe{sub 2}O{sub 3}, contributes to the improvement of the clinker properties obtained at low burning temperature. X-ray fluorescence spectroscopy, X-ray diffraction analysis and optical microscopy were used to determine the chemical and mineralogical compositions of this clinker. The samples were analyzed by means of a scanning electronic microscope connected with an energy-dispersive X-ray spectrometer to detect the composition of the belite phase and its morphology. Physical and mechanical properties of this clinker cement were determined. The results show that the belite clinker obtained at 1150 {sup o}C, with lime saturation factor 0.67, is characterized by a great hydraulic reactivity, similar to that of the ordinary alite clinker. The addition of 2% of NaF and the water quenching improved the chemical, mineralogical and structural properties, while improving the cement hydraulic properties.

36 MATERIALS SCIENCE↗