Search NASA⌕ Search

SEARCH · Search NASA

Results for “FNAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Heat Treatment Optimization of Rutherford Cables for a 15 T Nb 3 Sn Dipole Demonstrator

FNAL has been developing a 15 T Nb 3 Sn dipole demonstrator for a future Very High Energy pp Collider based on an optimized 60-mm aperture 4-layer “cos-theta” coil. In order to increase magnet efficiency, we graded the coil by using two cables with same 15 mm width and different thicknesses made of two different Restacked Rod Process (RRP®) wires. Due to the non-uniform field distribution in dipole coils the maximum field in the inner coil will reach 15-16 T, whereas the maximum field in the outer coil is 12-13 T. In preparation for the 15 T dipole coil reaction, heat treatment studies were performed on strands extracted from these cables with the goal of achieving the best coil performance in the corresponding magnetic fields. Particularly, the effect of maximum temperature and time on the cable critical current was studied to take into account actual variations of these parameters during coil reaction. In parallel and in collaboration with OST, development was performed on optimizing Nb 3 Sn RRP® wire design and layout. Index Terms— Accelerator magnet, critical current density, Nb 3 Sn strand, Rutherford cable.

43 PARTICLE ACCELERATORS↗

Performance of Superconducting Magnet Prototypes for LCLS-II Linear Accelerator

The new LCLS-II Linear Superconducting Accelerator at SLAC needs superconducting magnet packages installed inside SCRF Cryomodules to focus and steer an electron beam. Two magnet prototypes were built and successfully tested at Fermilab. Magnets have an iron dominated configuration, quadrupole and dipole NbTi superconducting coils, and splittable in the vertical plane configuration. Magnets inside the Cryomodule are conductively cooled through pure Al heat sinks. Both magnets performance was verified by magnetic measurements at room temperature, and during cold tests in liquid helium. Test results including magnetic measurements are discussed. Special attention was given to the magnet performance at low currents where the iron yoke and the superconductor hysteresis effects have large influence. Both magnet prototypes were accepted for the installation in FNAL and JLAB prototype Cryomodules.

43 PARTICLE ACCELERATORS↗

Fabrication of First 4-m Coils for the LARP MQXFA Quadrupole and Assembly in Mirror Structure

The US LHC Accelerator Research Program is constructing prototype interaction region quadrupoles as part of the US in-kind contribution to the Hi-Lumi LHC project. The low-beta MQXFA Q1/Q3 coils have a 4-m length and a 150 mm bore. The design is first validated on short, one meter models (MQXFS) developed as part of the longstanding Nb3Sn quadrupole R&D by LARP in collaboration with CERN. In parallel, facilities and tooling are being developed and refined at BNL, LBNL, and FNAL to enable long coil production, assembly, and cold testing. Long length scale-up is based on the experience from the LARP 90 mm aperture (TQ-LQ) and 120 mm aperture (HQ and Long HQ) programs. A 4-m long MQXF practice coil was fabricated, water jet cut and analyzed to verify procedures, parts, and tooling. In parallel, the first complete prototype coil (QXFP01a) was fabricated and assembled in a long magnetic mirror, MQXFPM1, to provide early feedback on coil design and fabrication following the successful experience of previous LARP mirror tests.

43 PARTICLE ACCELERATORS↗

The HL-LHC Low-β Quadrupole Magnet MQXF: From Short Models to Long Prototypes

Among the components to be upgraded in LHC interaction regions for the HiLumi-LHC projects are the inner triplet (or low-β) quadrupole magnets, denoted as Q1, Q2a, Q2b, and Q3. Here, the new quadrupole magnets, called MQXF, are based on Nb3Sn superconducting magnet technology and operate at a gradient of 132.6 T/m, with a conductor peak field of 11.4 T. Q1 and Q3 are composed of magnets (called MQXFA) fabricated by the U.S. Accelerator Upgrade Project (AUP), with a magnetic length of 4.2 m. Q2a and Q2b consist of magnets (called MQXFB) fabricated by CERN, with a magnetic length of 7.15 m. After a series of short models, constructed in close collaboration by the US and CERN, the development program is now entering in the prototyping phase, with CERN on one side and BNL, FNAL, and LBNL on the other side assembling and testing their first long magnets We provide in this paper a description of the status of the MQXF program, with a summary of the short model test results, including quench performance, and mechanics, and an update on the fabrication, assembly, and test of the long prototypes.

43 PARTICLE ACCELERATORS↗

Fabrication and Testing of 18-mm-Period, 0.5-m-Long Nb 3 Sn Superconducting Undulator

The Advanced Photon Source at Argonne National Laboratory, in collaboration with FNAL and LBNL, is developing a Nb 3 Sn superconducting undulator with the goal of installing this device on the APS storage ring and providing APS users with the novel radiation source. A series of short, similar to ~ 8-cm-long, 18-mm-period undulator prototype magnets have been designed, fabricated, and tested. The same design was scaled to fabricate a 0.5-m-long undulator prototype. Tests of this prototype showed that the designed peak magnetic field of 1.2 T at 850 A was successfully achieved. It represents at least a 20% improvement in comparison with a NbTi SCU having the same period and magnetic gap. Test results and lessons learned from the design process are reported here.

43 PARTICLE ACCELERATORS↗

Magnetic and Mechanical Analysis of a Large Aperture 15 T Cable Test Facility Dipole Magnet

The US Department of Energy (DOE) Office of Science (SC), is funding a large bore “Cable Test Facility Magnet” for testing advanced cables and inserts in high transverse field. This is a joint effort between the Office of High Energy Physics (HEP) and the Office of Fusion Energy Sciences (FES). The background field magnet for this facility is being developed at Lawrence Berkeley National Laboratory (LBNL) while the cryostat and test facility will be located and operated by Fermi National Accelerator Laboratory (FNAL). The Nb 3 Sn dipole magnet, which will provide the transverse background field, is designed to generate a field of 15 T in a 100 × 150 mm bore at 1.9 K. The conceptual design of a block-type dipole with flared ends and a structure based on key-and-bladder technology will be introduced. The results of the magnetic and mechanical analysis will be presented.

43 PARTICLE ACCELERATORS↗

Test of Superconducting Wires and Rutherford Cables With High Specific Heat

High-field accelerator magnets made of state-of-the-art Nb 3 Sn Rutherford cables demonstrate relatively long trainings due to sudden heat depositions originated by thermo-mechanical perturbations in the magnet coils. Coil sensitivity to these perturbations can be reduced by increasing the specific heat, Cp, of major coil components - strands, or whole cable, or epoxy. The R&D on all these three approaches is in progress. This paper studies feasibility of increasing the Cp of Rutherford-type cables by using a thin composite Cu/Gd 2 O 3 tape. The tape can be either wrapped around the cable, placed on the cable wide faces under the insulation, and/or inserted as a core. In this work, Cu/Gd 2 O 3 ribbons with ~30% of Gd 2 O 3 powder and two different thicknesses were produced by Hyper Tech Research, Inc. Wire and cable samples outfitted with these high-Cp ribbons, or tapes, were prepared and tested at FNAL for the Minimum Quench Energy (MQE). At 80%Ic, the MQE gain average over the tested magnetic field range of the NbTi cable with high-Cp tape on both sides was ~1.3. The MQE gain average of the NbTi wire wrapped with the high-Cp ribbon was 3.1.

43 PARTICLE ACCELERATORS↗

Assembly and Pre-Loading Specifications for the Series Production of the Nb 3 Sn MQXFA Quadrupole Magnets for the HL-LHC

We report the High Luminosity LHC (HL-LHC) Project is planning to install 16 cold-masses made with Nb 3 Sn quadrupole magnets in the LHC Interaction Regions to significantly increase its luminosity. Half of these cold masses are fabricated at BNL, FNAL, and LBNL under the US Accelerator Research Program (AUP). Each cold mass includes two identical Nb 3 Sn quadrupole magnets, called MQXFA with a magnetic length of 4.2 m. Currently, the AUP project has completed the fabrication and test of the first 5 pre-series magnets, and is working on the following 16 magnets for the series production. The brittleness and strain sensitivity of the Nb 3 Sn superconducting material requires a careful definition of the allowable maximum stress in the windings during magnet assembly and pre-load, and a tight control of their variation within the whole coil length. Therefore, a series of assembly and pre-load specifications have been defined with the goals of minimizing the risk of conductor degradation and providing the mechanical support required to reach the nominal current during powering. In this paper we present the specifications defined for the MQXFA magnets and applied during the different assembly phases and during the pre-load process of the first 5 pre-series magnets.

43 PARTICLE ACCELERATORS↗

Development of a Small-Aperture Cos-theta Dipole Insert Coil Based on Bi2212 Rutherford Cable and Stress Management Structure

The U.S. Magnet Development Program (US-MDP) is developing high-field accelerator magnets with magnetic fields beyond the limits of Nb3Sn technology based on high temperature superconductor Bi 2 Sr 2 CaCu 2 O 8-x (Bi2212). However, Bi2212 wires and cables are sensitive to transverse stresses and strains, which are substantial in high-field accelerator magnets. To prevent large degradation of the Bi2212 coils and achieve the required field quality, an innovative design which provides turn positioning during coil fabrication and operation and manage azimuthal and radial strains/stresses in the coil has been proposed at FNAL. This paper describes the development of a small-aperture two-layer Bi2212 dipole coil with stress management. The main parameters of the Bi2212 wire and Rutherford cable, the design of coil stress management structure and its plastic model, the coil mechanical analysis in the dipole mirror configuration are presented and discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Minimum Quench Energy of Nb 3 Sn Wires With High Specific Heat Tape

A major problem of state-of-the-art Nb3Snaccelerator magnets is their long training due to thermo-mechanical perturbations. Increasing the specific heat, Cp, of the Rutherford cable would reduce and/or eliminate training by limiting the coils temperature rise. This paper studies feasibility of increasing the Cp of Rutherford-type cables by using thin composite Cu/Gd 2 O 3 and Cu/Gd 2 O 2 S tapes produced by HyperTech Research, Inc. The tape can be either wrapped around the cable, placed on the cable wide faces under the insulation, and/or inserted as a core. Wire samples outfitted with these high-Cp ribbons, or tapes, were prepared and tested at FNAL for their Minimum Quench Energy (MQE). At 90%Ic and 15 T, the average gain of MQE of the Nb 3 Sn wire soldered to the Cu/Gd 2 O 2 S 55 μm thick ribbon was 2.5, and further increased at larger transport currents.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Assessment and Performance of Flexible Quench Antenna Array Diagnostics for Superconducting Magnets

FNAL has been developing multiple versions of flexible quench antennas (flex-QA), including some specially optimized for high sensitivity and/or high resolution, to characterize quench events and transients during current ramping in superconducting magnets. A fundamental feature in our use of these is the creation of grid-like structures of sensitive elements to cover coil surfaces, with the aim of getting precise localization of magnetic flux-change events. The flex-QA are coupled with fast data-acquisition, allowing comprehensive analysis of signals at the relevant fine time scales. In addition to arrays of various flex-QA types being used during cryogenic testing of superconducting magnets, we also are utilizing a newly developed room temperature test stand to better understand QA response characteristics. The data from actual superconducting magnet tests, warm test stand measurements, and simulation data on the same QA designs allows us to draw conclusions on operational feasibility and plan better for improvements of our sensors. In this paper we present data from the multiple tests performed and analysis results. Flex-QA designs are compared, and their features, options, and optimization discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of the High Field Cable Test Facility at Fermilab

Fermi National Accelerator Laboratory (FNAL) and Lawrence Berkeley National Laboratory (LBNL) are building a new High Field Vertical Magnet Test Facility (HFVMTF) for testing superconducting cables in high magnetic field. The background magnetic field of 15 T in the HFVMTF will be produced by a magnet provided by LBNL. The HFVMTF is jointly funded by the US DOE Offices of Science, High Energy Physics (HEP), and Fusion Energy Sciences (FES), and will serve as a superconducting cable test facility in high magnetic fields and a wide range of temperatures for HEP and FES communities. This facility will also be used to test high-field superconducting magnet models and demonstrators, including hybrid magnets, produced by the US Magnet Development Program (MDP). The paper describes the status of the facility, including construction, cryostat designs, top and lambda plates, and systems for powering, and quench protection and monitoring.

43 PARTICLE ACCELERATORS↗

Commissioning, Performance, and Effect of the Quench Current-Boosting Device on a Dedicated Superconducting Magnet

Superconducting magnet training is one of the accelerator related issues attracting attention due to significant operational costs and time budget associated to it. It is especially worrisome that magnets based on the “next-generation” Nb 3 Sn technology are affected by long training. While various efforts are underway to better understand and resolve the problem a parallel path could also be investigated, a path bypassing the issue. Following the concept of fast induced over-current during magnet powering, FNAL has developed an upgradable capacitor-based device to discharge through a superconducting magnet at quench detection or operator chosen time. The 0.4 F/1 kV device has been tested on a 1-m-long dipole-coil in a “mirror” magnet configuration and conclusive results on magnet training elimination have been observed. Here in this paper we discuss the main characteristics of the device, compare simulated response and actual performance, elaborate on test drivers and outcomes. Next steps and perspectives for future use are debated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of Flex-QA Arrays in HTS Magnet Testing

Flexible PCB quench antennas have been very useful in providing high-quality high-resolution data in low temperature superconducting magnet tests. Similar multi-sensor arrays have been employed recently to cover a high temperature superconductor magnet tested at FNAL. In the present work, data taking conditions and magnet features to support the analysis framework are discussed. Then observations made during complete magnet powering cycles are described and analysis of quench antenna data are presented. Based on results, improvements to instrumentation and data taking are debated. Views on the future of flexible quench antenna sensors for HTS magnet diagnostics and operational support are shared.

43 PARTICLE ACCELERATORS↗

Searches for new-physics effects in the D0 experiment: Latest results

The latest results obtained in searches for particles and phenomena beyond the Standard Model (new-physics effects) in the D0 experiment at the Tevatron accelerator (FNAL, United States) on the basis of statistics corresponding to the integrated luminosity of about 1 fb{sup -1} are surveyed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Latest results of searches for new physics in the D0 experiment

Results on searches for particles and phenomena beyond the Standard Model (new-physics effects) in the D0 experiment at the Tevatron accelerator (FNAL, USA) are examined. These results were obtained on the basis of a statistical sample corresponding to an integrated luminosity of 5 to 7 fb{sup -1} and were published in 2010 and 2011.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First samples of Ti and Nb tubes explosion welding joint with stainless steel for ILC 1.8 K cryomodule

The world first samples of Ti and Nb tubes joint with stainless steel ones by an explosion welding by the JINR-VNIIEF-FNAL-INFN cooperation were manufactured in the frame of ILC R&D programe. An applying methods of relaxation of residual tensions (after explosion and electron beam welding), macro- and microanalyses of welding seam and cryogenic tests of the samples produced manifest the achievement of high mechanic strength (≈250 MPa/share) of welding seam, solidity and leak absence on 10{sup −10} l atm/s level at 1.8 K. The explosion welding technology and methods introducing to industrial manufacturing of the 4-th generation of cryomodule of TESLA TYPE DESIGN can exclude the Ti—communications, connect the Nb—cavity with stainless steel vessel and reduce significantly the accelerator cost.

43 PARTICLE ACCELERATORS↗

Fermilab proton accelerator complex status and improvement plans

Fermilab carries out an extensive program of accelerator-based high energy particle physics research at the Intensity Frontier that relies on the operation of 8 GeV and 120 GeV proton beamlines for a n umber of fixed target experiments. Routine operation with a world-record 700kW of average 120 GeV beam power on the neutrino target was achieved in 2017 as the result of the Proton Improvement Plan (PIP) upgrade. There are plans to further increase the power to 900 – 1000 kW. The next major upgrade of the FNAL accelerator complex, called PIP-II, is under development. It aims at 1.2MW beam power on target at the start of the LBNF/DUNE experiment in the middle of the next decade and assumes replacement of the existing 40-years old 400 MeV normal-conducting Linac with a modern 800 MeV superconducting RF linear accelerator. There are several concepts to further double the beam power to >2.4MW after replacement of the existing 8 GeV Booster synchrotron. In this article we discuss current performance of the Fermilab proton accelerator complex, the upgrade plans for the next two decades and the accelerator R&D program to address cost and performance risks for these upgrades.

43 PARTICLE ACCELERATORS↗