Search NASA⌕ Search

SEARCH · Search NASA

Results for “FORENSIC SCIENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Application of the 226 Ra- 230 Th- 234 U and 227 Ac- 231 Pa- 235 U radiochronometers to UF 6 Cylinders

Uranium-series radiometric dating was performed on two well-pedigreed UF 6 cylinder samples containing highly enriched uranium that were in use at the Portsmouth Gaseous Diffusion Plant between the mid-1970s and mid-1980s. Daughter-parent (i.e. 231 Pa- 235 U, 230 Th- 234 U) radiometric ages determined on solid heel materials (e.g. UO 2 F 2 , UF 4 ) recovered from the emptied cylinders resulted in unrealistically old ages due to the preferential sequestration of progeny isotopes within the solid heels. However, limited elemental fractionation amongst the progeny isotopes themselves in the heel material allowed for useful age constraints on the fill dates of the UF6 cylinders to be extracted from the granddaughter-daughter systems (i.e. 226 Ra- 230 Th, 227 Ac- 231 Pa).

07 ISOTOPE AND RADIATION SOURCES↗

Spatially Resolved Characterization of Water and Ion Incorporation in Bacillus Spores

Here we present the first direct visualization and quantification of water and ion uptake into the core of individual dormant Bacillus thuringiensis subsp. israelensis (B. thuringiensis subsp. israelensis) endospores. Isotopic and elemental gradients in the B. thuringiensis subsp. israelensis spores show the permeation and incorporation of deuterium in deuterated water (D 2 O) and solvated ions throughout individual spores, including the spore core. Under hydrated conditions, incorporation into a spore occurs on a time scale of minutes, with subsequent uptake of the permeating species continuing over a period of days. The distribution of available adsorption sites is shown to vary with the permeating species. Adsorption sites for Li + , Cs + , and Cl - are more abundant within the spore outer structures (exosporium, coat, and cortex) relative to the core, while F - adsorption sites are more abundant in the core. The results presented here demonstrate that elemental abundance and distribution in dormant spores are influenced by the ambient environment. As such, this study highlights the importance of understanding how microbial elemental and isotopic signatures can be altered postproduction, including during sample preparation for analysis, and therefore, this study is immediately relevant to the use of elemental and isotopic markers in environmental microbiology and microbial forensics.

59 BASIC BIOLOGICAL SCIENCES↗

The Microbial DNA Index System (MiDIS): A tool for microbial pathogen source identification

The microbial DNA Index System (MiDIS) is a concept for a microbial forensic database and investigative decision support system that can be used to help investigators identify the sources of microbial agents that have been used in a criminal or terrorist incident. The heart of the proposed system is a rigorous method for calculating source probabilities by using certain fundamental sampling distributions associated with the propagation and mutation of microbes on disease transmission networks. This formalism has a close relationship to mitochondrial and Y-chromosomal human DNA forensics, and the proposed decision support system is somewhat analogous to the CODIS and SWGDAM mtDNA databases. The MiDIS concept does not involve the use of opportunistic collections of microbial isolates and phylogenetic tree building as a basis for inference. A staged approach can be used to build MiDIS as an enduring capability, beginning with a pilot demonstration program that must meet user expectations for performance and validation before evolving into a continuing effort. Because MiDIS requires input from a a broad array of expertise including outbreak surveillance, field microbial isolate collection, microbial genome sequencing, disease transmission networks, and laboratory mutation rate studies, it will be necessary to assemble a national multi-laboratory team to develop such a system. The MiDIS effort would lend direction and focus to the national microbial genetics research program for microbial forensics, and would provide an appropriate forensic framework for interfacing to future national and international disease surveillance efforts.

59 BASIC BIOLOGICAL SCIENCES↗

National Nuclear Materials Archive (NNMA) - Specimen Selection and Sampling at the Y-12 National Security Complex

Y-12 has made significant progress in FY21 towards National Nuclear Materials Archive (NNMA) program objectives related to the identification, nomination, sampling, sub-sampling and shipment of NNMA materials. Y-12 efforts in FY22 and beyond are anticipated to transition away from material identification and nomination to an emphasis on sampling/sub-sampling and long-term storage of NNMA specimens. Long-term storage efforts will also involve more emphasis on insuring that the nuclear forensics value of NNMA items is guaranteed through appropriate preservation processes.

36 MATERIALS SCIENCE↗

Development of a Course in Gamma Ray Spectrometry

The majority of undergraduate and graduate students in nuclear science and engineering take a general course in nuclear instrumentation where one of the topics is typically in gamma ray spectrometry. Rarely are courses offered solely on this subject matter other than intensified workshops conducted by the International Atomic Energy Agency (IAEA) or private companies which can be expensive especially for large groups of students. Currently there are many world-wide projects in routine monitoring and advanced research that employ gamma rays. Some but not an exhaustive list of these topics include neutron activation analysis, naturally occurring radioactivity materials (NORM), nuclear forensics, nuclear security, in-situ gamma ray detection, galactic gamma ray detection, health physics and advanced instrumentation. At the Nuclear Engineering Teaching Laboratory at the University of Texas at Austin, many of our students are involved in an array of research topics that involve gamma ray spectrometry in their Masters of Science theses, PhD dissertations and special topics courses. It was decided to invest the time and effort to develop a course with a strong technical component to complement their research activities. A detailed stand-alone course in gamma ray spectrometry that includes a series lectures in modular form has been developed. As well we have incorporated fourteen advanced animations to better explain some of the fundamental physical processes and experimental set-ups. Six laboratory sessions and multiple homework assignments have also been established. This course is applicable to senior undergraduate students, graduate students, and novice researchers the above mentioned fields in a traditional class/laboratory setting or for intense one to two week workshops. A great deal of effort was undertaken to prepare a stand-alone course in gamma ray spectrometry which includes many of the fundamental aspects as well as the more advanced instrumentation. Animations of gamma ray interactions and experimental set ups were also developed. Six laboratories and six assignments were also conceived. Every topic has its own module thus a 'pick and choose' subset of lectures can be given to different levels of understanding. This course is applicable to senior undergraduate students, graduate students, novice researchers in neutron activation analysis and naturally occurring radioactive material, and for intense one to two week workshops. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PIXE – State of the Art, Systems, Challenges

Particle-induced X-ray emission (PIXE) is an analytical technique for elemental analysis in which a charged-particle beam (most commonly protons, but also alpha particles or heavier ions) ionizes inner-shell electrons in target atoms. When these vacancies are filled by outer-shell electrons, the atom emits characteristic X-rays (e.g., Kα, Kβ, L-series) whose energies are unique to each element. Measuring the X-ray spectrum therefore enables identification of the elements present and, with appropriate calibration and modeling, their concentration. PIXE provides rapid, simultaneous, quantitative multi-element detection with trace-level sensitivity for many mid- to high-Z elements, often with minimal sample preparation. It is widely used across materials science (thin films, alloys, corrosion), geology (mineral chemistry, provenance) and environmental monitoring (aerosols, particulates, soils); semiconductor contamination analysis (wafer surface/trace metals), cultural heritage (pigments, inks, archaeological artifacts) and forensics (gunshot residue, glass/pain), and biological/medical studies (tissue/biomaterial trace-element mapping).

47 OTHER INSTRUMENTATION↗

High sensitivity measurement of femtogram-level 238 Pu by thermal ionization mass spectrometry with correction of background 238 U

Low-concentration plutonium isotopic measurements provide a valuable fingerprint to identify possible material origins in the context of environmental contamination monitoring, environmental tracing, nuclear safeguards, nuclear forensics, and treaty monitoring. Thermal ionization mass spectrometry (TIMS) has long been recognized as one of the most sensitive techniques for plutonium isotopic measurement, but has not generally been utilized for 238 Pu determination, especially at low concentrations, due to an isobaric interference from 238 U, prevalent as background. Here, this work demonstrates a new analytical technique for correction of background 238 U from the 238 Pu counts collected during a TIMS analysis. The technique takes advantage of the higher ionization temperature of U relative to Pu and uses a 235 U tracer added after plutonium purification chemistry for 238 U semi-quantitative determination. This technique has been successfully applied to the determination of 238 Pu concentration and the 238 Pu/ 239 Pu ratio in sample types including single-isotope standards, isotopic certified reference materials, matrix-containing environmental reference materials, and simulated nuclear detonation debris. The results have been directly compared on a sample-by-sample basis to alpha spectrometry results. The detection limit by this new technique is 0.23 fg 238 Pu, which was previously unachievable by mass spectrometry and is possible in around 1 h of analysis time post-chemistry compared to weeks of required counting time by alpha spectrometry (at the same atom amount). We also present original, high precision data for Pu isotope concentrations in IAEA-384, Fangataufa Sediment, including 242 Pu results for the first time. The new technique allows measurement of a key isotope, 238 Pu, that was previously not measured in small environmental or nuclear forensics collections.

238Pu↗

Three-dimensional microstructural characterization of bulk plutonium and uranium metals using focused ion beam technique

Nuclear forensics requires accurate quantification of discriminating microstructural characteristics of the bulk nuclear material to identify its process history and provenance. Conventional metallographic preparation techniques for bulk plutonium (Pu) and uranium (U) metals are limited to providing information in two-dimension (2D) and do not allow for obtaining depth profile of the material. In this contribution, use of dual-beam focused ion-beam/scanning electron microscopy (FIB-SEM) to investigate the internal microstructure of bulk Pu and U metals is demonstrated. Our results demonstrate that the dual-beam methodology optimally elucidate microstructural features without preparation artifacts, and the three-dimensional (3D) characterization of inner microstructures can reveal salient microstructural features that cannot be observed from conventional metallographic techniques. As a result, examples are shown to demonstrate the benefit of FIB-SEM in improving microstructural characterization of microscopic inclusions, particularly with respect to nuclear forensics.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Single particle trace element analysis of uranium oxide standards with laser-induced breakdown spectroscopy

Femtosecond Laser-Induced Breakdown Spectroscopy (LIBS) was used to analyze over 1000 individual particles of uranium oxide trace element standard CRM124. Intra-granular analysis showed elemental concentrations were consistent across different surface locations on each uranium grain. However, inter-granular comparison revealed large heterogeneity between different grains of the same sample. By comparing the distribution of elemental concentrations across the particle populations, we were able to correctly identify a manufacturing process involving wet chemistry, rather than a dry mixing of two powders to give an overall chemical average. In conclusion, this demonstrates the utility of LIBS as a large-scale single particle analysis tool for nuclear forensics.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

New Radiological Material Detection Technologies for Nuclear Forensics: Remote Optical Imaging and Graphene-Based Sensors

We developed new detector technologies to identify the presence of radioactive materials for nuclear forensics applications. First, we investigated an optical radiation detection technique based on imaging nitrogen fluorescence excited by ionizing radiation. We demonstrated optical detection in air under indoor and outdoor conditions for alpha particles and gamma radiation at distances up to 75 meters. We also contributed to the development of next generation systems and concepts that could enable remote detection at distances greater than 1 km, and originated a concept that could enable daytime operation of the technique. A second area of research was the development of room-temperature graphene-based sensors for radiation detection and measurement. In this project, we observed tunable optical and charged particle detection, and developed improved devices. With further development, the advancements described in this report could enable new capabilities for nuclear forensics applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Volatility Studies of Lanthanide Hexafluoroacetylacetone Chelates

Nuclear forensics has become very important to the field of nuclear security, where there is considerable interest in developing rapid separations of radionuclides and isotopes. Although prevention and detection form the foundation of nuclear security science, in the unfortunate event of detonation of a nuclear device, the fallout debris can be analyzed for signature isotopes that may provide evidence on the origin and type of nuclear materials. This is of considerable political importance to many governing bodies and this information is desired in a timely manner. One method of analysis is the rapid gas phase separation of rare earth metals from other components of the debris via isothermal thermochromatography. Lanthanides cover a portion of the fission product curve with varying yields dependent on a number of variables (e.g. neutron energy, fissile parent, etc), motivating the chromatographic separation of these elements. In previous work, 1,1,1,5,5,5 - hexafluoroacetylacetone (hfac) has been shown to produce volatile complexes with lanthanides. Thermochromatography is a gas phase separation method that utilizes temperature gradients on a column to vary adsorption location or constant column temperatures to vary retention time. The adsorption time of a compound on a column, i.e. retention time, is dependent on the thermodynamics, most notably the adsorption enthalpy. Studies of heavy metals have generated empirical correlations between adsorption enthalpy on a quartz column and sublimation enthalpy of the solid material. Thermogravimetric analysis (TGA) is useful in the characterization of the thermodynamics of materials, especially the sublimation enthalpy. Many methods analyze weight loss curves as a function of a constant heating rate. Another method introduced by Ashcroft analyzes weight loss curves over isothermal heating regions. Work presented here focuses on the determination of the sublimation enthalpies of thirteen lanthanide hfac complexes via the latter method. Additionally, there is investigation into the degradation of the compound via constant heating TGA up to higher temperatures. This provides information on the onset and end-set temperatures of degradation stages, as well as the peak temperature at which total sublimation occurs. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Morphological and chemical characteristics of oxide scales formed on δ-Phase plutonium metal alloys I: 3.5 at% ga

Focused ion-beam scanning electron microscopy (FIB-SEM) and three-dimensional (3D) microscopy were applied to characterize the subsurface morphological features of oxide scales formed on an ~3.5 at.% Ga plutonium (Pu) metal alloy. Using the FIB-SEM technique, a number of morphological features formed in the interior of the oxide scale from Pu metal's environmental exposure were observed and identified. Here, Auger electron spectroscopy (AES) was utilized to characterize the cross-sectional composition and chemistry of the oxide scale. The oxide scale formed during inert storage and operational environments has a characteristic internal scale structure that includes a relatively dense oxide layer with some lateral and transverse cracking. Generally, after subsequent exposure to dry air environment, the oxide scale retained most of the original structural and chemical characteristics. However, after aging in a moist air environment, while the oxide scale was found to maintain the chemical characteristics of the source oxide, the scale was found to be on average thinner and without the previously observed internal microcracking, likely the result of spallation of the source scale during exposure to the new environment.

36 MATERIALS SCIENCE↗

Morphological and chemical characteristics of oxide scales formed on δ-phase plutonium metal alloys II: 2.0 at% Ga

The focused ion-beam scanning electron microscopy (FIB-SEM) and three-dimensional (3D) microscopy were applied to characterize the subsurface morphological features of oxide scales formed on an ~2.0 at. % Ga plutonium (Pu) metal alloy. Using the FIB-SEM technique, a number of morphological features formed in the interior of the oxide scale from Pu metal’s environmental exposure were observed and identified. Auger electron spectroscopy (AES) was utilized to characterize the cross-sectional composition and chemistry of the oxide scale. The oxide scale formed during inert storage and operational environments was found to be highly variable in thickness and morphology, presenting some regions with a thin (<400 nm), dense oxide layer and others with a thick (>2 µm) scale with substantial lateral cracking. After subsequent exposure to dry air environment, the oxide scale became thicker (~4 µm) and slightly more porous. The changes following aging in a moist air environment were observed to be more severe, with the formation of a highly porous internal structure containing significant lateral and transverse cracking. In comparison to the scale formed on an ~3.5 at. % Ga-Pu metal alloy, the oxide morphology of the lower gallium alloy investigated here exhibited greater variation in thickness and a noteworthy dependence on the presence of water vapor, particularly in terms of the internal porosity formed during growth of the oxide.

36 MATERIALS SCIENCE↗

Intrinsic Dosimetry: Elemental Composition Effects on the Thermoluminescence of Commercial Borosilicate Glass

Intrinsic dosimetry is the method of measuring total absorbed dose received by the walls of a container holding radioactive material. By considering this dose in tandem with the physical characteristics of the radioactive material housed within the container, this method can provide enhanced pathway information for interdicted radioactive samples. Thermoluminescence (TL) dosimetry was used to measure ionizing radiation dose effects on stock borosilicate glass. Differences in TL glow curve shape and intensity were observed for glasses from different geographical origins. The different TL signatures strongly correlated with the concentration of alkaline earth metals and the ratio of sodium to the total amount of alkali metal present in the borosilicate glass.

61 RADIATION PROTECTION AND DOSIMETRY↗