Search NASASearch

SEARCH · Search NASA

Results for “FREQUENCY MODULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Differential Absorption Radar at 170 GHz for Atmospheric Boundary Layer Water Vapor Profiling

We are developing a frequency-modulated continuous-wave (FMCW) radar between 167 and 174.8 GHz to measure differential absorption due to water vapor within the atmospheric boundary layer. In this work, we report on single-frequency measurements performed within this band in the presence of precipitating clouds. Despite the relatively low transmit power of 6-10 dBm, the high transmit/receive isolation and low noise figure of the system enables detection of radar echos from rain or clouds with high signal-to-noise ratio (SNR) out to about one kilometer. Near future upgrades to the system that will lengthen significantly the detectable range include a 15 to 20 dB increase in output power and 20 dB increase in antenna gain. This work builds on technology developed and measurements performed in our group in the 183.5 to 193 GHz band, which is subject to transmission restrictions due to passive remote sensing platforms that rely on those frequencies.

Rodriguez Monje, Raquel

Demodulation techniques for use at Goonhilly satellite-communication earth station

As part of the programme of experimental and development work to determine the optimum demodulating techniques for communication satellite systems, three types of demodulators have been investigated at the Goonhilly earth station: 1.A conventional demodulator of the type used in 960-channel telephony or television microwave radio-relay links; 2.A frequency modulation feed-back demodulator in which the deviation of the signal is reduced before it reaches the final discriminator; and 3.A variable-bandwidth 'dynamic-tracking' demodulator in which the resonant frequency of a narrow bandwidth tuned circuit is moved rapidly to follow the nominal instantaneous frequency of the incoming signal. The conventional demodulator will not be discussed in detail here;. however, information is given on two specialized demodulators.

COMMUNICATIONS SATELLITE

Variability of accretion disks surrounding black holes: The role of inertial-acoustic mode instabilities

The global nonlinear time-dependent evolution of the inertial-acoustic mode instability in accretion disks surrounding black holes has been investigated. The viscous stress is assumed to be proportional to the gas pressure only, i.e., tau = alphap(sub g). It is found that an oscillatory nonsteady behavior exists in the inner regions of disks (r is less than 10r(sub g) where r(sub g) is the Schwarzschild radius) for sufficiently large alpha(greater than or approximately equal to 0.2) and for mass accretion rates less than about 0.3 times the Eddington value. The variations of the integrated bolometric luminosity from the disk, Delta L/L, are less than 3%. A power spectrum analysis of these variations reveals a power spectrum which can be fitted to a power-law function of the frequency Pis proportional to f(exp -gamma), with index gamma = 1.4-2.3 and a low-frequency feature at about 4 Hz in one case. In addition, a narrow peak centered at a frequency corresponding to the maximum epicyclic frequency of the disk at approximately 100-130 Hz and its first harmonic is also seen. The low-frequency modulations are remarkably similar to those observed in black hole candidate systems. The possible existence of a scattering corona in the inner region of the disk and/or other processes contributing to the power at high frequencies in the inner region of the accretion disk may make the detection of the high-frequency component difficult.

Chen, Xingming

An upgraded G-band differential absorption radar system for future airborne studies

A proof-of-concept, 170 GHz frequency-modulated, continuous-wave (FMCW) radar has been developed for measuring water vapor profiles within the cloudy boundary layer from an airborne platform. The measurement concept exploits the differential absorption accrued by two or more transmitted frequencies in the vicinity of the 183 GHz water absorption line to retrieve range-resolved humidity profiles, so-called differential absorption radar (DAR). The upgraded system design includes important considerations for monostatic radar operation with an open fuselage viewport (i.e. no radome). The radar features an all-solid-state tansmitter with > 0:4 W continuous transmit power, a 60 cm primary aperture and corresponding 58 dB antenna gain, and more than 80 dB transmit/receive isolation, enabling near thermal-noise-limited sensitivity with a 8 dB noise figure receiver. Ice-cloud radar returns are detected beyond 8 km in height from the ground, demonstrating the high sensitivity of the system. In addition to in-cloud humidity profiling capabilities, deployment of a water vapor DAR from an airborne platform enables measurements of total column water vapor (TCWV) for all weather and surface scenarios. Precision estimates and potential biases for future TCWV measurements are discussed.

Monje, Raquel

Low-cost FM oscillator for capacitance type of blade tip clearance measurement system

The frequency-modulated (FM) oscillator described is part of a blade tip clearance measurement system that meets the needs of a wide class of fans, compressors, and turbines. As a result of advancements in the technology of ultra-high-frequency operational amplifiers, the FM oscillator requires only a single low-cost integrated circuit. Its carrier frequency is 42.8 MHz when it is used with an integrated probe and connecting cable assembly consisting of a 0.81 cm diameter engine-mounted capacitance probe and a 61 cm long hermetically sealed coaxial cable. A complete circuit analysis is given, including amplifier negative resistance characteristics. An error analysis of environmentally induced effects is also derived, and an error-correcting technique is proposed. The oscillator can be calibrated in the static mode and has a negative peak frequency deviation of 400 kHz for a rotor blade thickness of 1.2 mm. High-temperature performance tests of the probe and 13 cm of the adjacent cable show good accuracy up to 600 C, the maximum permissible seal temperature. The major source of error is the residual FM oscillator noise, which produces a clearance error of + or - 10 microns at a clearance of 0.5 mm. The oscillator electronics accommodates the high rotor speeds associated with small engines, the signals from which may have frequency components as high as 1 MHz.

Barranger, John P.

Auto-programmable impulse neural circuits

Impulse neural networks use pulse trains to communicate neuron activation levels. Impulse neural circuits emulate natural neurons at a more detailed level than that typically employed by contemporary neural network implementation methods. An impulse neural circuit which realizes short term memory dynamics is presented. The operation of that circuit is then characterized in terms of pulse frequency modulated signals. Both fixed and programmable synapse circuits for realizing long term memory are also described. The implementation of a simple and useful unsupervised learning law is then presented. The implementation of a differential Hebbian learning rule for a specific mean-frequency signal interpretation is shown to have a straightforward implementation using digital combinational logic with a variation of a previously developed programmable synapse circuit. This circuit is expected to be exploited for simple and straightforward implementation of future auto-adaptive neural circuits.

Watula, D.

Detector For FM Voice Or Digital Signals

Frequency-modulation (FM) detector operates with either analog audio (usually voice) signals or digital signals sent by differential minimum-shift keying (DMSK). Performance expected similar to conventional limiter/discriminator FM detectors. Detector operates at baseband, obviating need for band-pass filtering at intermediate frequency. Baseband version made in very-large-scale integrated circuit. New detector useful in mobile communications, where trend is toward integrated voice and data service.

Davarian, Faramaz

All-sky search in early O3 LIGO data for continuous gravitational-wave signals from unknown neutron stars in binary systems

Rapidly spinning neutron stars are promising sources of continuous gravitational waves. Detecting such a signal would allow probing of the physical properties of matter under extreme conditions. A significant fraction of the known pulsar population belongs to binary systems. Searching for unknown neutron stars in binary systems requires specialized algorithms to address unknown orbital frequency modulations. We present a search for continuous gravitational waves emitted by neutron stars in binary systems in early data from the third observing run of the Advanced LIGO and Advanced Virgo detectors using the semicoherent, GPU-accelerated, binaryskyhough pipeline. The search analyzes the most sensitive frequency band of the LIGO detectors, 50–300 Hz. Binary orbital parameters are split into four regions, comprising orbital periods of three to 45 days and projected semimajor axes of two to 40 light seconds. No detections are reported. We estimate the sensitivity of the search using simulated continuous wave signals, achieving the most sensitive results to date across the analyzed parameter space.

Gravitation

Pulse-modulated dual-gas control subsystem for space cabin atmosphere

An atmosphere control subsystem (ACS) was developed for use in a closed manned cabin, such as the Space Shuttle Orbiter. This subsystem uses the Perkin Elmer mass spectrometer for continuous measurement of major atmospheric constituents (H2, H2O, N2, O2, and CO2). The O2 and N2 analog signals are used as inputs to the controller, which produces a pulse-frequency-modulated output to operate the N2 gas admission solenoid valve and an on-off signal to operate the O2 valve. The proportional controller characteristic results in improved control accuracy as compared with previously used on-off controllers having significant dead-band. A 60-day evaluation test was performed on the ACS during which operation was measured at various values of control setpoint and simulated cabin leakage.

Jackson, J. K.

Absolute Position of Targets Measured Through a Chamber Window Using Lidar Metrology Systems

Lidar is a useful tool for taking metrology measurements without the need for physical contact with the parts under test. Lidar instruments are aimed at a target using azimuth and elevation stages, then focus a beam of coherent, frequency modulated laser energy onto the target, such as the surface of a mechanical structure. Energy from the reflected beam is mixed with an optical reference signal that travels in a fiber path internal to the instrument, and the range to the target is calculated based on the difference in the frequency of the returned and reference signals. In cases when the parts are in extreme environments, additional steps need to be taken to separate the operator and lidar from that environment. A model has been developed that accurately reduces the lidar data to an absolute position and accounts for the three media in the testbed air, fused silica, and vacuum but the approach can be adapted for any environment or material. The accuracy of laser metrology measurements depends upon knowing the parameters of the media through which the measurement beam travels. Under normal conditions, this means knowledge of the temperature, pressure, and humidity of the air in the measurement volume. In the past, chamber windows have been used to separate the measuring device from the extreme environment within the chamber and still permit optical measurement, but, so far, only relative changes have been diagnosed. The ability to make accurate measurements through a window presents a challenge as there are a number of factors to consider. In the case of the lidar, the window will increase the time-of-flight of the laser beam causing a ranging error, and refract the direction of the beam causing angular positioning errors. In addition, differences in pressure, temperature, and humidity on each side of the window will cause slight atmospheric index changes and induce deformation and a refractive index gradient within the window. Also, since the window is a dispersive media, the effect of both phase and group indices have to be considered. Taking all these factors into account, a method was developed to measure targets through multiple regions of different materials and produce results that are absolute measurements of target position in three-dimensional space, rather than simply relative position. The environment in which the lidar measurements are taken must be broken down into separate regions of interest and each region solved for separately. In this case, there were three regions of interest: air, fused silica, and vacuum. The angular position of the target inside the chamber is solved using only phase index and phase velocity, while the ranging effects due to travel from air to glass to vacuum/air are solved with group index and group velocity. When all parameters are solved simultaneously, an absolute knowledge of the position of each target within an environmental chamber can be derived. Novel features of this innovation include measuring absolute position of targets through multiple dispersive and non-dispersive media, deconstruction of lidar raw data from a commercial off-the-shelf unit into reworkable parameters, and use of group velocities to reduce range data. Measurement of structures within a vacuum chamber or other harsh environment, such as a furnace, may now be measured as easily as if they were in an ambient laboratory. This analysis permits transformation of the raw data into absolute spatial units (e.g., mm). This technique has also been extended to laser tracker, theodolite, and cathetometer measurements through refractive media.

Kubalak, David

Superorbital Periodic Modulation in Wind-Accretion High-Mass X-Ray Binaries from Swift Burst Alert Telescope Observations

We report the discovery using data from the Swift-Burst Alert Telescope (BAT) of superorbital modulation in the wind-accretion supergiant high-mass X-ray binaries 4U 1909+07 (= X 1908+075), IGR J16418−4532, and IGR J16479−4514. Together with already known superorbital periodicities in 2S 0114+650 and IGR J16493−4348, the systems exhibit a monotonic relationship between superorbital and orbital periods. These systems include both supergiant fast X-ray transients and classical supergiant systems, and have a range of inclination angles. This suggests an underlying physical mechanism which is connected to the orbital period. In addition to these sources with clear detections of superorbital periods, IGR J16393−4643 (= AX J16390.4−4642) is identified as a system that may have superorbital modulation due to the coincidence of low-amplitude peaks in power spectra derived from BAT, Rossi X-Ray Timing Explorer Proportional Counter Array, and International Gamma-Ray Astrophysics Laboratory light curves. 1E 1145.1−6141 may also be worthy of further attention due to the amount of low-frequency modulation of its light curve. However, we find that the presence of superorbital modulation is not a universal feature of wind-accretion supergiant X-ray binaries.

superorbital

Power spectra of quasi-periodic oscillations in luminous X-ray stars

A variety of partial random processes are considered in order to study the effects on the power-density spectrum of several physical phenomena that may occur in the beat-frequency modulated accretion (BFMA) model of QPOs. The relevant physical properties of BFMA model are summarized, and the class of random processes used to represent the X-ray intensity time series predicted by the model are introduced. The dependence of the power-density spectrum on pulse shape is discussed. Pulse-lifetime and orbital-frequency distributions are introduced, illustrating how these affect the power-density spectrum. The effect of nonuniform initial-pulse phase distributions and of nonuniform pulse-time distributions are considered. The effects of a particular type of pulse-to-pulse correlation that may be natural in the context of the BFMA model and that greatly increases the power of the oscillations relative to that in the red noise is analyzed.

Shibazaki, N.

Apollo 9 multiband photography experiment S065

Fourier analysis was applied to microdensitometer scans of a selected region of one SO65 frame in each of the three black-and-white bands. The approach was unique because a somewhat arbitrary section of the image was used and not limited to available targets as in edge analysis. Comparison of duplicates and calculation of absolute SO65 MTF were done by applying linear systems theory to the spatial spectra of the image scans. It was found that the duplication process was nonlinear and resulted in general amplification of spatial frequency modulation. However, the increase in modulation was offset by a corresponding increase in the granularity of the copies. The amount of increase seemed to be related to the initial granularity, but a direct relationship was not verified. Band-to-band comparison of image quality was achieved in the form of signal-to-noise ratio curves as a function of spatial frequency for each band. From this standpoint the DD band was an order of magnitude better than the other two. These were several factors that restricted the analysis of the Apollo 9 imagery. Among these were the lack of precise sensitometric and optical system data on the high altitude photography. In addition it was determined that there was only one simultaneous pair of high altitude and SO65 frames. Finally, the original SO65 photography was not available for scanning (for obvious reasons), thus eliminating a reference base for granularity and SO65 MTF determination.

Schowengerdt, R. A.

Optimization of A 2-Micron Laser Frequency Stabilization System for a Double-Pulse CO2 Differential Absorption Lidar

A carbon dioxide (CO2) Differential Absorption Lidar (DIAL) for accurate CO2 concentration measurement requires a frequency locking system to achieve high frequency locking precision and stability. We describe the frequency locking system utilizing Frequency Modulation (FM), Phase Sensitive Detection (PSD), and Proportional Integration Derivative (PID) feedback servo loop, and report the optimization of the sensitivity of the system for the feed back loop based on the characteristics of a variable path-length CO2 gas cell. The CO2 gas cell is characterized with HITRAN database (2004). The method can be applied for any other frequency locking systems referring to gas absorption line.

Chen, Songsheng

Device for recording the 20 Hz - 200 KHz sound frequency spectrum using teletransmission

The device described consists of two distinct parts: (1) The sound pickup system consisting of the wide-frequency band condenser microphone which contains in the same assembly the frequency-modulated oscillator and the output stage. Being transistorized and small, this system can be easily moved, so that sounds can be picked up even in places that are difficult to reach with larger devices. (2) The receiving and recording part is separate and can be at a great distance from the sound pickup system. This part contains a 72 MHz input stage, a frequency changer that gives an intermediate frequency of 30 MHz and a multichannel analyzer coupled to an oscilloscope and a recorder.

Baciu, I.

Computer simulation of TDRSS autotracking

The Tracking and Data Relay Satellite System (TDRSS) consists of synchronous-orbit satellites and a single ground station at White Sands, NM. Each TDRSS satellite has two 16-foot dish antennas with dual-frequency feeds for transmission and reception at S- and Ku-band. Autotracking is required on the Ku-band return link from user spacecraft. The TDRSS autotrack system was verified by computer simulation rather than by end-to-end hardware testing. One of the simulation models is described. Attention is given to an overview of system operation, a computer model description, and the simulation results. An example plot shows the sensitivity of system pointing error to user incidental amplitude modulation frequency.

Jones, S. C.

Data Acquisition and Prompt Analysis System for High Altitude Balloon Experiments

An inexpensive and simple data acquisition system has been developed for balloon borne experiments and has been tested with a gamma ray detector in a balloon flight launched from Palestine, Texas. The detector used for the test consisted of an NaI(T1) scintillation crystal encased in a 1/8 in. plastic scintillator-charged particle shield. The combination was viewed by a single photomultiplier and charged particle gating was accomplished by a conventional phoswich discriminator. The pulse height analysis of the NaI events, not associated with prompt charged particle interactions, is accomplished by converting to a time spectrum using an airborne height to time converter. A range of pulse widths from 5 microseconds to 250 microseconds corresponds to energy losses in NaI from 100 to 1000 keV. The time spectrum information, along with charged particle events and barometric pressure, is fed to a mixer which modulates a 252.4 Mc FM transmitter. The original scintillator spectrum is recovered on the ground utilizing conversion circuitry at the receiver video output and a 128 channel commercial pulse height analyzer. The charged particle events of standard time width are stored with the spectrum at a fixed channel position and are therefore represented by a sharp line riding on the lower part of the NaI energy loss spectrum. An energy loss greater than 1000 keV is presented by the maximum pulse width of the converter and stored in the last analyzer channel. Barometric pressure data is transmitted by low frequency modulation of the sme FM carrier. In flight operation, the receiver video output can be recorded on a wide band tape recorder and simultaneously analyzed by the 128 channel analyzer, or the telemetered data can be analyzed later. The flight system features high pulse resolution, essentially instantaneous time response, high data rate, and flexibility; and is of modest cost. A detailed description of the system and operating performance is discussed.

Sarkady, A. A.

Cosmic ray secular variations in terrestrial records and aurorae

The rediscovery that the Sun and the solar wind can undergo important changes on historical time scales has brought into question the stability of the cyclic behavior of past time series of solar and solar-terrestrial origin. It was found by Vector Fourier analysis that the solar 11 year cycle is present in the series of 10Be, delta 180, in ice cores and of thermoluminescence (TL) in sea sediments during the last Millennia with a frequency modulation, related to the Sun behavior, as tested by comparison with the Sunspot number R sub z series. It was shown that the cyclogram of the series of yearly Aurorae from 1721 to 1979 linear-regression-corrected-for-R sub z is straight for the periodicity zeta=11,1y, which indicates that such periodicity is constant in time corresponding to the only line present in the 11y band. The maxima of this component appear at the same time together with the high speed solar wind streams taking place in coronal holes situated in high heliolatitudes. It is evidenced that the 11 year cycle has undergone frequency oscillations on a time scale of two centuries, although it is very difficult to determine the periodicities with high accuracy.

Attolini, M. R.