Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY MODULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Superorbital Periodic Modulation in Wind-Accretion High-Mass X-Ray Binaries from Swift Burst Alert Telescope Observations

We report the discovery using data from the Swift-Burst Alert Telescope (BAT) of superorbital modulation in the wind-accretion supergiant high-mass X-ray binaries 4U 1909+07 (= X 1908+075), IGR J16418−4532, and IGR J16479−4514. Together with already known superorbital periodicities in 2S 0114+650 and IGR J16493−4348, the systems exhibit a monotonic relationship between superorbital and orbital periods. These systems include both supergiant fast X-ray transients and classical supergiant systems, and have a range of inclination angles. This suggests an underlying physical mechanism which is connected to the orbital period. In addition to these sources with clear detections of superorbital periods, IGR J16393−4643 (= AX J16390.4−4642) is identified as a system that may have superorbital modulation due to the coincidence of low-amplitude peaks in power spectra derived from BAT, Rossi X-Ray Timing Explorer Proportional Counter Array, and International Gamma-Ray Astrophysics Laboratory light curves. 1E 1145.1−6141 may also be worthy of further attention due to the amount of low-frequency modulation of its light curve. However, we find that the presence of superorbital modulation is not a universal feature of wind-accretion supergiant X-ray binaries.

superorbital↗

Power spectra of quasi-periodic oscillations in luminous X-ray stars

A variety of partial random processes are considered in order to study the effects on the power-density spectrum of several physical phenomena that may occur in the beat-frequency modulated accretion (BFMA) model of QPOs. The relevant physical properties of BFMA model are summarized, and the class of random processes used to represent the X-ray intensity time series predicted by the model are introduced. The dependence of the power-density spectrum on pulse shape is discussed. Pulse-lifetime and orbital-frequency distributions are introduced, illustrating how these affect the power-density spectrum. The effect of nonuniform initial-pulse phase distributions and of nonuniform pulse-time distributions are considered. The effects of a particular type of pulse-to-pulse correlation that may be natural in the context of the BFMA model and that greatly increases the power of the oscillations relative to that in the red noise is analyzed.

Shibazaki, N.↗

Apollo 9 multiband photography experiment S065

Fourier analysis was applied to microdensitometer scans of a selected region of one SO65 frame in each of the three black-and-white bands. The approach was unique because a somewhat arbitrary section of the image was used and not limited to available targets as in edge analysis. Comparison of duplicates and calculation of absolute SO65 MTF were done by applying linear systems theory to the spatial spectra of the image scans. It was found that the duplication process was nonlinear and resulted in general amplification of spatial frequency modulation. However, the increase in modulation was offset by a corresponding increase in the granularity of the copies. The amount of increase seemed to be related to the initial granularity, but a direct relationship was not verified. Band-to-band comparison of image quality was achieved in the form of signal-to-noise ratio curves as a function of spatial frequency for each band. From this standpoint the DD band was an order of magnitude better than the other two. These were several factors that restricted the analysis of the Apollo 9 imagery. Among these were the lack of precise sensitometric and optical system data on the high altitude photography. In addition it was determined that there was only one simultaneous pair of high altitude and SO65 frames. Finally, the original SO65 photography was not available for scanning (for obvious reasons), thus eliminating a reference base for granularity and SO65 MTF determination.

Schowengerdt, R. A.↗

Optimization of A 2-Micron Laser Frequency Stabilization System for a Double-Pulse CO2 Differential Absorption Lidar

A carbon dioxide (CO2) Differential Absorption Lidar (DIAL) for accurate CO2 concentration measurement requires a frequency locking system to achieve high frequency locking precision and stability. We describe the frequency locking system utilizing Frequency Modulation (FM), Phase Sensitive Detection (PSD), and Proportional Integration Derivative (PID) feedback servo loop, and report the optimization of the sensitivity of the system for the feed back loop based on the characteristics of a variable path-length CO2 gas cell. The CO2 gas cell is characterized with HITRAN database (2004). The method can be applied for any other frequency locking systems referring to gas absorption line.

Chen, Songsheng↗

Device for recording the 20 Hz - 200 KHz sound frequency spectrum using teletransmission

The device described consists of two distinct parts: (1) The sound pickup system consisting of the wide-frequency band condenser microphone which contains in the same assembly the frequency-modulated oscillator and the output stage. Being transistorized and small, this system can be easily moved, so that sounds can be picked up even in places that are difficult to reach with larger devices. (2) The receiving and recording part is separate and can be at a great distance from the sound pickup system. This part contains a 72 MHz input stage, a frequency changer that gives an intermediate frequency of 30 MHz and a multichannel analyzer coupled to an oscilloscope and a recorder.

Baciu, I.↗

Computer simulation of TDRSS autotracking

The Tracking and Data Relay Satellite System (TDRSS) consists of synchronous-orbit satellites and a single ground station at White Sands, NM. Each TDRSS satellite has two 16-foot dish antennas with dual-frequency feeds for transmission and reception at S- and Ku-band. Autotracking is required on the Ku-band return link from user spacecraft. The TDRSS autotrack system was verified by computer simulation rather than by end-to-end hardware testing. One of the simulation models is described. Attention is given to an overview of system operation, a computer model description, and the simulation results. An example plot shows the sensitivity of system pointing error to user incidental amplitude modulation frequency.

Jones, S. C.↗

Data Acquisition and Prompt Analysis System for High Altitude Balloon Experiments

An inexpensive and simple data acquisition system has been developed for balloon borne experiments and has been tested with a gamma ray detector in a balloon flight launched from Palestine, Texas. The detector used for the test consisted of an NaI(T1) scintillation crystal encased in a 1/8 in. plastic scintillator-charged particle shield. The combination was viewed by a single photomultiplier and charged particle gating was accomplished by a conventional phoswich discriminator. The pulse height analysis of the NaI events, not associated with prompt charged particle interactions, is accomplished by converting to a time spectrum using an airborne height to time converter. A range of pulse widths from 5 microseconds to 250 microseconds corresponds to energy losses in NaI from 100 to 1000 keV. The time spectrum information, along with charged particle events and barometric pressure, is fed to a mixer which modulates a 252.4 Mc FM transmitter. The original scintillator spectrum is recovered on the ground utilizing conversion circuitry at the receiver video output and a 128 channel commercial pulse height analyzer. The charged particle events of standard time width are stored with the spectrum at a fixed channel position and are therefore represented by a sharp line riding on the lower part of the NaI energy loss spectrum. An energy loss greater than 1000 keV is presented by the maximum pulse width of the converter and stored in the last analyzer channel. Barometric pressure data is transmitted by low frequency modulation of the sme FM carrier. In flight operation, the receiver video output can be recorded on a wide band tape recorder and simultaneously analyzed by the 128 channel analyzer, or the telemetered data can be analyzed later. The flight system features high pulse resolution, essentially instantaneous time response, high data rate, and flexibility; and is of modest cost. A detailed description of the system and operating performance is discussed.

Sarkady, A. A.↗

Cosmic ray secular variations in terrestrial records and aurorae

The rediscovery that the Sun and the solar wind can undergo important changes on historical time scales has brought into question the stability of the cyclic behavior of past time series of solar and solar-terrestrial origin. It was found by Vector Fourier analysis that the solar 11 year cycle is present in the series of 10Be, delta 180, in ice cores and of thermoluminescence (TL) in sea sediments during the last Millennia with a frequency modulation, related to the Sun behavior, as tested by comparison with the Sunspot number R sub z series. It was shown that the cyclogram of the series of yearly Aurorae from 1721 to 1979 linear-regression-corrected-for-R sub z is straight for the periodicity zeta=11,1y, which indicates that such periodicity is constant in time corresponding to the only line present in the 11y band. The maxima of this component appear at the same time together with the high speed solar wind streams taking place in coronal holes situated in high heliolatitudes. It is evidenced that the 11 year cycle has undergone frequency oscillations on a time scale of two centuries, although it is very difficult to determine the periodicities with high accuracy.

Attolini, M. R.↗

Multi-pixel high-resolution three-dimensional imaging radar

A three-dimensional imaging radar operating at high frequency e.g., 670 GHz radar using low phase-noise synthesizers and a fast chirper to generate a frequency-modulated continuous-wave (FMCW) waveform, is disclosed that operates with a multiplexed beam to obtain range information simultaneously on multiple pixels of a target. A source transmit beam may be divided by a hybrid coupler into multiple transmit beams multiplexed together and directed to be reflected off a target and return as a single receive beam which is demultiplexed and processed to reveal range information of separate pixels of the target associated with each transmit beam simultaneously. The multiple transmit beams may be developed with appropriate optics to be temporally and spatially differentiated before being directed to the target. Temporal differentiation corresponds to a different intermediate frequencies separating the range information of the multiple pixels. Collinear transmit beams having differentiated polarizations may also be implemented.

Cooper, Ken B.↗

Near fields in the vicinity of pulsed electron beams in space

Most measurements of the radio frequency emissions from artificial electron beams in space have been made in close proximity to the beam. This paper presents theory and results for the near-field radiation associated with the operation of a pulsed electron beam, taking into account the effects of the ionospheric plasma. The beam is modeled as an infinite train of square-wave pulses and the radiation is obtained by adding coherently the radiation from each individual electron in the idealized helical trajectory assumed by the beam as it traverses the magnetized plasma. The mathematical solution is obtained by taking the Fourier transform in space and time of Maxwell's equations and the driving modulated beam current, and then taking the inverse transform of the resulting electric field. Typical electric field strengths are presented for a range of modulation frequencies extending from below the ion cyclotron to the electron cyclotron frequency.

Harker, K. J.↗

Analysis of mode-locked and intracavity frequency-doubled Nd:YAG laser

The paper presents analytical and computer studies of the CW mode-locked and intracavity frequency-doubled Nd:YAG laser which provide new insight into the operation, including the detuning behavior, of this type of laser. Computer solutions show that the steady-state pulse shape for this laser is much closer to a truncated cosine than to a Gaussian; there is little spectral broadening for on-resonance operation; and the chirp is negligible. This leads to a simplified analytical model carried out entirely in the time domain, with atomic linewidth effects ignored. Simple analytical results for on-resonance pulse shape, pulse width, signal intensity, and harmonic conversion efficiency in terms of basic laser parameters are derived from this model. A simplified physical description of the detuning behavior is also developed. Agreement is found with experimental studies showing that the pulsewidth decreases as the modulation frequency is detuned off resonance; the harmonic power output initially increases and then decreases; and the pulse shape develops a sharp-edged asymmetry of opposite sense for opposite signs of detuning.

Siegman, A. E.↗

A narrowband, crystal controlled biomedical telemetry system.

A miniature, single-channel, crystal-controlled transmitter has been developed for biomedical applications. A narrow-band frequency modulation (plus or minus 7 kHz) of the RF is used to achieve maximum operating range with minimum transmitting power. The radiated power is limited to stay within the 50 microvolts/m at 15 m FCC requirement for low-power transmitters in the 88- to 108-MHz band. This technique offers a number of advantages. First only manufacturer's type approval is required for the device and the user does not need a license. Second maximum operating range can be achieved within the FCC power limitations by using a narrow-band that is consistent with the required medical information bandwidth. A third advantage in using the 88- to 108-MHz band is that the commercial FM stations are relatively widely spaced and carefully regulated so that by selecting the transmitter's frequency in the guard band between stations, minimum interference from other transmitter sources is encountered.

Westbrook, R. M.↗

Quantitative Species Measurements In Microgravity Combustion Flames

The capability of models and theories to accurately predict and describe the behavior of low gravity flames can only be verified by quantitative measurements. Although video imaging, simple temperature measurements, and velocimetry methods have provided useful information in many cases, there is still a need for quantitative species measurements. Over the past decade, we have been developing high sensitivity optical absorption techniques to permit in situ, non-intrusive, absolute concentration measurements for both major and minor flames species using diode lasers. This work has helped to establish wavelength modulation spectroscopy (WMS) as an important method for species detection within the restrictions of microgravity-based measurements. More recently, in collaboration with Prof. Dahm at the University of Michigan, a new methodology combining computed flame libraries with a single experimental measurement has allowed us to determine the concentration profiles for all species in a flame. This method, termed ITAC (Iterative Temperature with Assumed Chemistry) was demonstrated for a simple laminar nonpremixed methane-air flame at both 1-g and at 0-g in a vortex ring flame. In this paper, we report additional normal and microgravity experiments which further confirm the usefulness of this approach. We also present the development of a new type of laser. This is an external cavity diode laser (ECDL) which has the unique capability of high frequency modulation as well as a very wide tuning range. This will permit the detection of multiple species with one laser while using WMS detection.

Chen, Shin-Juh↗

A new technique for simultaneous monitoring of electrocardiogram and walking cadence

A new technique for simultaneously recording continuous electrocardiographic (ECG) data and walking step rate (cadence) is described. The ECG and gait signals are recorded on 2 channels of an ambulatory Holter monitor. Footfall is detected using ultrathin, force-sensitive foot switches and is frequency modulated. The footfall signal provides an indication of the subject's activity (walking or standing), as well as the instantaneous walking rate. Twenty-three young and elderly subjects were studied to demonstrate the use of this ECG and gait recorder. High-quality gait signals were obtained in all subjects, and the effects of walking on the electrocardiogram were assessed. Initial investigation revealed the following findings: (1) Although walking rates were similar in young and elderly subjects, the elderly had both decreased heart rate (HR) variability (p < 0.005) and increased cadence variability (p < 0.0001). (2) Overall, there was an inverse relation between HR and cadence variability (r = -0.73). Three elderly subjects with no known cardiac disease had HR and cadence variability similar to those of the young, whereas elderly subjects with history of congestive heart failure were among those with the lowest HR variability and the highest cadence variability. (3) Low-frequency (approximately equal to 0.1 Hz) HR oscillations (frequently observed during standing) persisted during walking in all young subjects. (4) In some subjects, both step rate and HR oscillated at the same low frequency (approximately equal to 0.1 Hz) previously identified with autonomic control of the baroreflex.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Cardiopulmonary↗

A MAGNETIC CORE VOLTAGE-TO-FREQUENCY CONVERTER

Controlling the frequency of a square-loop magnetic core oscillator using a dc voltage to give a voltage-to-frequency conversion for use in pulse frequency modulated telemetry systems

PFM TELEMETRY↗

PFM Simulator

Pulse frequency modulation simulator for design and testing of telemetry equipment for satellite systems

SATELLITE INSTRUMENTATION↗

Voltage variable oscillator has high phase stability

Two or more series RLC circuits are used with a negative feedback amplifier to make a voltage variable oscillator. This combination results in high phase stability and optimum frequency modulation.

Hearn, C. P.↗