An analytic technique for statistically modeling random atomic clock errors in estimation

Minimum variance estimation requires that the statistics of random observation errors be modeled properly. If measurements are derived through the use of atomic frequency standards, then one source of error affecting the observable is random fluctuation in frequency. This is the case, for example, with range and integrated Doppler measurements from satellites of the Global Positioning and baseline determination for geodynamic applications. An analytic method is presented which approximates the statistics of this random process. The procedure starts with a model of the Allan variance for a particular oscillator and develops the statistics of range and integrated Doppler measurements. A series of five first order Markov processes is used to approximate the power spectral density obtained from the Allan variance.

Fell, P. J.↗

Study of multiple optical transitions in 87Rb using laser diodes

Recent work with laser diodes has indicated their potential usefulness in optically pumping atomic frequency standards. Various optical pumping schemes for (87)Rb incorporating such light sources at two D1 frequencies for experimental situations of either evacuated wall-coated cells or atomic beams are considered. Numerical integration of rate equations governing the level populations with arbitrary pumping light choices of intensity, D1 hyperfine transition(s), and polarization and subsequent calculation of scattered light provide a simplified 0-0 hyperfine signal analysis. By frequency modulating one laser diode, two optical transitions were excited in an evacuated wall-coated cell and a large delta m(F) = 1 hf signal was observed.

Newton, C. L. J.↗

Effect of thermal cycling on stress in metallic films on ceramic substrates

The hydrogen maser is the most stable frequency standard currently available for averaging intervals of hours to weeks. A major contributor to maser frequency variations is the maser's microwave resonant cavity: by means of the cavity pulling effect, a change in the cavity's resonance frequency produces a proportional change in the maser's output frequency. To minimize variations in the cavity's dimensions, and thus in its resonance frequency, maser cavities are often constructed of a low-expansivity glass-ceramic material coated on its surface with a conductive metallic film. It was previously shown that silver films like those used in SAO maser cavities develop tensile stress when cooled to room temperature after being fired onto the cavity, and that the stress in such films relaxes with time at a rate proportional to the level of stress. Stress relaxation in maser cavity coatings can alter the shape, and hence the resonance frequency, of the cavity, resulting in a slow variation in the maser's output frequency. The possibility was investigated of reversing the initial tensile stress by precooling the coated cavity material. It was hypothesized that cooling the material well below its normal working temperature and then warming it to its normal temperature would result in a lower tensile stress or even a compressive stress. Under such a condition stress relaxation, and thus any consequent frequency drifts, might be reduced or reversed.

Mattison, Edward M.↗

CO2 laser oscillators for laser radar applications

This paper reviews the spectral purity, frequency stability, and long-term stabilization of newly developed CO2 isotope lasers. Extremely high spectral purity, and short-term stability of less than 1.5 x 10 to the -13th have been achieved. A brief description on using CO2 isotope lasers as secondary frequency standards and in optical radar is given. The design and output characteristics of a single frequency, TEM00q mode, variable pulse width, hybrid TE CO2 laser system is also described. The frequency chirp in the output has been measured and almost completely eliminated by means of a novel technique.

Freed, C.↗

Nonadiabatic nonradial p-mode frequencies of the standard solar model, with and without helium diffusion

The nonadiabatic frequencies of a standard solar model and a solar model that includes helium diffusion are discussed. The nonadiabatic pulsation calculation includes physics that describes the losses and gains due to radiation. Radiative gains and losses are modeled in both the diffusion approximation, which is only valid in optically thick regions, and the Eddington approximation, which is valid in both optically thin and thick regions. The calculated pulsation frequencies for modes with l less than or equal to 1320 are compared to the observed spectrum of the Sun. Compared to a strictly adiabatic calculation, the nonadiabatic calculation of p-mode frequencies improves the agreement between model and observation. When helium diffusion is included in the model the frequencies of the modes that are sensitive to regions near the base of the convection zone are improved (i.e., brought into closer agreement with observation), but the agreement is made worse for other modes. Cyclic variations in the frequency spacings of the Sun as a function of frequency of n are presented as evidence for a discontinuity in the structure of the Sun, possibly located near the base of the convection zone.

Guenther, D. B.↗

Precise time and Time Interval (PTTI) measurements from the navigation technology satellites and the GPS NAVSTAR-4 satellite

A time domain estimate for the NAVSTAR-4 SV clock offset was obtained for each SV pass over the GPS monitor sites, using a smoothed reference ephemeris, with corrections for ionospheric delay, tropospheric delay, earth rotation and relativistic effects. Conversion from the time domain to the frequency domain was made using the two sample Allan Variance; sigma-tau plots used to identify the noise processes. Estimates of flicker and white frequency noise for the NAVSTAR-4 rubidium frequency standard were obtained. The contribution of the reference ground clocks and other error sources to the frequency stability estimates were also considered.

Buisson, J. A.↗

A frequency and timing subsystem for the ORION mobile unit

A mobile surveying instrument in support of the crustal dynamics program measures the length and direction of the distance between sites on the Earth's surface using VLBI techniques operating at microwave frequencies and extragalactic radio sources. The frequency and timing subsystem uses as a frequency standard the hydrogen maser. An important part of the subsystem is a sophisticated automatic system to monitor frequency stability and accumulated clock error.

Clements, P. A.↗

Computer simulations of ions in radio-frequency traps

The motion of ions in a trapped-ion frequency standard affects the stability of the standard. In order to study the motion and structures of large ion clouds in a radio-frequency (RF) trap, a computer simulation of the system that incorporates the effect of thermal excitation of the ions was developed. Results are presented from the simulation for cloud sizes up to 512 ions, emphasizing cloud structures in the low-temperature regime.

Williams, A.↗

A look into the crystal ball: The next 25 years

The PTTI Planning Meeting was born at about the same time as the atomic definition of the unit of time, the second. This use of the cesium resonance was made possible by advances in quantum electronics during the preceding decade which resulted in commercial availability of cesium, rubidium, and hydrogen clocks and frequency standards. Twenty-five years later these types of clocks still are the backbone of time and frequency applications; together with a variety of crystal oscillators, transmitters, and receivers, as well as signal distribution, conditioning and switching systems, atomic clocks are an essential part of the infrastructure of modern navigation and communication technology. The next 25 years undoubtedly will see a pervasive expansion of PTTI into the infrastructure that supports and leverages industrial, social, environmental, defense, and even individual human activities. Speculation as to what capabilities, services, and personal conveniences may become available will be limited by two factors: the degree to which existing device concepts can be made more affordable and reliable, and the ability to miniaturize for purposes of compatibility with electronic integration. With regard to the latter, history teaches us that the required technological breakthrough is unlikely to originate in existing technology; thus, we may expect a paradigm shift in PTTI device concepts not unlike the shift in the 1960s from vacuum tubes to semiconductors.

Hellwig, Helmut↗

Test of relativistic gravitation with a space-borne hydrogen maser

The results of a test of general relativity with use of a hydrogen-maser frequency standard in a spacecraft launched nearly vertically upward to 10,000 km are reported. The agreement of the observed relativistic frequency shift with prediction is at the 70 x 10 to the -6th level.

Vessot, R. F. C.↗

Ground-Based Investigations with the Cryogenic Hydrogen Maser

The room temperature hydrogen maser is an active atomic oscillator used as a high-frequency-stability local oscillator for radio astronomy, metrology, and spacecraft navigation, and in tests of fundamental physics. The cryogenic hydrogen maser (CHM) operates at 0.5 K, employing superfluid helium-coated walls to store the masing hydrogen atoms. We are investigating whether the CHM may provide better frequency stability than the room temperature hydrogen maser: one to three orders of magnitude improvement may be possible because of greatly reduced thermal noise and larger signal power. Exceptional frequency stability will be required for spacecraft tracking in future deep-space missions, for space-based tests of relativity and gravitation, and for local (i.e., flywheel) oscillators used with absolute frequency standards such as laser-cooled atomic fountains and linear ion traps. These new devices are passive high-resolution frequency discriminators. Alone, they cannot function as superior atomic clocks; their effective operation depends on being integrated with an active local oscillator with excellent short term stability - such as that possible with the CHM.

Walsworth, Ronald L.↗

DSN system performance test Doppler noise models; noncoherent configuration

The newer model for variance, the Allan technique, now adopted for testing, is analyzed in the subject mode. A model is generated (including considerable contribution from the station secondary frequency standard), and rationalized with existing data. The variance model is definitely sound; the Allan technique mates theory and measure. The mean-frequency model is an estimate; this problem is yet to be rigorously resolved. The unaltered defining expressions are noncovergent, and the observed mean is quite erratic.

Bunce, R.↗

Time and frequency requirement for the earth and ocean physics applications program

The application of time and frequency standards to the Earth and Ocean Physics Applications Program (EOPAP) is discussed. The goals and experiments of the EOPAP are described. Methods for obtaining frequency stability and time synchronization are analyzed. The orbits, trajectories, and characteristics of the satellites used in the program are reported.

Vonbun, F. O.↗

The time and frequency comparisons via Loran-C and National TV Network in Yugoslavia

Time comparisons were made between cesium clocks in Yugoslavia and other cesium clocks in the country by the Laboratory of Federal Bureau of Measures and Precious Metals. Regional standard frequency and time signals dissemination is over National TV network by so called active TV system. International comparisons are performed via Loran-C system and by clock transportation. The method of calculation and approximation of the time signal propagation delays is given. Settled comparison results of the cesium clocks via TV network, Loran-C, and by clock transportation are also discussed in this paper.