Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fault characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Rectenna array measurement results

The measured performance characteristics of a rectenna array are reviewed and compared to the performance of a single element. It is shown that the performance may be extrapolated from the individual element to that of the collection of elements. Techniques for current and voltage combining were demonstrated. The array performance as a function of various operating parameters is characterized and techniques for overvoltage protection and automatic fault clearing in the array demonstrated. A method for detecting failed elements also exists. Instrumentation for deriving performance effectiveness is described. Measured harmonic radiation patterns and fundamental frequency scattered patterns for a low level illumination rectenna array are presented.

Dickinson, R. M.↗

Distributed deformation and block rotation in 3D

The authors address how block rotation and complex distributed deformation in the Earth's shallow crust may be explained within a stationary regional stress field. Distributed deformation is characterized by domains of sub-parallel fault-bounded blocks. In response to the contemporaneous activity of neighboring domains some domains rotate, as suggested by both structural and paleomagnetic evidence. Rotations within domains are achieved through the contemporaneous slip and rotation of the faults and of the blocks they bound. Thus, in regions of distributed deformation, faults must remain active in spite of their poor orientation in the stress field. The authors developed a model that tracks the orientation of blocks and their bounding faults during rotation in a 3D stress field. In the model, the effective stress magnitudes of the principal stresses (sigma sub 1, sigma sub 2, and sigma sub 3) are controlled by the orientation of fault sets in each domain. Therefore, adjacent fault sets with differing orientations may be active and may display differing faulting styles, and a given set of faults may change its style of motion as it rotates within a stationary stress regime. The style of faulting predicted by the model depends on a dimensionless parameter phi = (sigma sub 2 - sigma sub 3)/(sigma sub 1 - sigma sub 3). Thus, the authors present a model for complex distributed deformation and complex offset history requiring neither geographical nor temporal changes in the stress regime. They apply the model to the Western Transverse Range domain of southern California. There, it is mechanically feasible for blocks and faults to have experienced up to 75 degrees of clockwise rotation in a phi = 0.1 strike-slip stress regime. The results of the model suggest that this domain may first have accommodated deformation along preexisting NNE-SSW faults, reactivated as normal faults. After rotation, these same faults became strike-slip in nature.

Scotti, Oona↗

Late Proterozoic evolution of the northern part of the Hamisana zone, northeast Sudan - Constraints on Pan-African accretionary tectonics

This paper describes deformation fabrics developed in the northern part of the Hamisana zone in northeast Sudan. New structural data are presented which establish a structural chronology that characterizes distinct events of accretion, folding, and thrust faulting and reactivation of accretion-related faults. The structural data point to an intraplate compressional origin for the Hamisana zone. A review of available isotopic age data is carried out, and it is concluded that Pan-African accretionary processes may have been analogous to Phanerozoic ophiolite and island arc accretion in the western North American Cordillera, where penetrative deformation occurred in response to periodic intraplate shortening events, rather than an ultimate collision of unrelated crustal fragments.

Miller, M. M.↗

Examining the Role of IMU Health Characterization and Monitoring in UAS Safety

Inertial measurement units (IMUs) can be vital for vehicle attitude and position estimation in unmanned aerial vehicles (UAVs). Degradation in these units could result in incorrect position estimates that are utilized in vehicle control, trajectory prediction, and other critical systems; however, the modes and effects of degradation in these IMUs are not well understood. In order to quantify the risk posed by degradation in these sensors, a study was conducted on the types of IMUs prevalent in the commercial market, their known failure modes, and the applicability to health monitoring methods for risk reduction and increased safety in an increasingly autonomous airspace. First, use cases and failure modes of the various types and reliability of commercially available IMUs were reviewed, and knowledge gaps and issues in the field were identified. Noting that inexpensive and lightweight MEMS (Microelectromechanical Systems) IMUs are some of the most commonly used but least reliable sensors in sUAS (small Unmanned Aerial Systems), five inexpensive MEMS IMUs were chosen for a performance evaluation study, selected from the Pixhawk autopilot systems, hobby sUAS, and prior NASA experimental studies. For each of these IMUs, a 10-minute bias test and a 12-hour drift test were performed for the accelerometers in a benchtop setting, using a BeagleBone Black for data collection. Using these results, the sensors’ performance is compared to their reported specifications, and the utility of implementing diagnostic methods for MEMS IMUs for research and commercial applications is evaluated. The paper concludes with a planned study for the evaluation of vibration-induced degradation for the selected sensors.

IMUs↗

Fault tolerance using self-checking building-block computers

The paper attempts to define and characterize a set of VLSI (very large scale integration) building-block circuits which can be used to combine existing microprocessors and memories into a wide variety of fault-tolerant computing systems. Such VLSI circuits would transform fault-tolerant computing into an off-the-shelf technology and enable its routine use for new applications. The self-checking computer module (SCCM) is the basic component out of which fault-tolerant computer systems are constructed. Several fault-tolerant configurations of SCCM are discussed, including the standby redundant uniprocessor, the voted/hybrid uniprocessor, and the distributed computer network.

Rennels, D. A.↗

Slip and Dilation Tendency Analysis of the Patua Geothermal Area

Critically stressed fault segments have a relatively high likelihood of acting as fluid flow conduits (Sibson, 1994). As such, the tendency of a fault segment to slip (slip tendency; Ts; Morris et al., 1996) or to dilate (dilation tendency; Td; Ferrill et al., 1999) provides an indication of which faults or fault segments within a geothermal system are critically stressed and therefore likely to transmit geothermal fluids. The slip tendency of a surface is defined by the ratio of shear stress to normal stress on that surface: Ts = T / on (Morris et al., 1996). Dilation tendency is defined by the stress acting normal to a given surface: Td = (o1-on) / (o1-o3) (Ferrill et al., 1999). Slip and dilation were calculated using 3DStress (Southwest Research Institute). Slip and dilation tendency are both unitless ratios of the resolved stresses applied to the fault plane by ambient stress conditions. Values range from a maximum of 1, a fault plane ideally oriented to slip or dilate under ambient stress conditions to zero, a fault plane with no potential to slip or dilate. Slip and dilation tendency values were calculated for each fault in the focus study areas at, McGinness Hills, Neal Hot Springs, Patua, Salt Wells, San Emidio, and Tuscarora on fault traces. As dip is not well constrained or unknown for many faults mapped in within these we made these calculations using the dip for each fault that would yield the maximum slip tendency or dilation tendency. As such, these results should be viewed as maximum tendency of each fault to slip or dilate. The resulting along-fault and fault-to-fault variation in slip or dilation potential is a proxy for along fault and fault-to-fault variation in fluid flow conduit potential. Stress Magnitudes and directions Stress field variation within each focus area was approximated based on regional published data and the world stress database (Hickman et al., 2000; Hickman et al., 1998 Robertson-Tait et al., 2004; Hickman and Davatzes, 2010; Davatzes and Hickman, 2006; Blake and Davatzes 2011; Blake and Davatzes, 2012; Moeck et al., 2010; Moos and Ronne, 2010 and Reinecker et al., 2005) as well as local stress information if applicable. For faults within these focus systems we applied either a normal faulting stress regime where the vertical stress (sv) is larger than the maximum horizontal stress (shmax) which is larger than the minimum horizontal stress (sv>shmax>shmin) or strike-slip faulting stress regime where the maximum horizontal stress (shmax) is larger than the vertical stress (sv) which is larger than the minimum horizontal stress (shmax >sv>shmin) depending on the general tectonic province of the system. Based on visual inspection of the limited stress magnitude data in the Great Basin we used magnitudes such that shmin/shmax = .527 and shmin/sv= .46, which are consistent with complete and partial stress field determinations from Desert Peak, Coso, the Fallon area and Dixie valley (Hickman et al., 2000; Hickman et al., 1998 Robertson-Tait et al., 2004; Hickman and Davatzes, 2011; Davatzes and Hickman, 2006; Blake and Davatzes 2011; Blake and Davatzes, 2012). Slip and dilation tendency analysis for the Patua geothermal system was calculated based on faults mapped in the Hazen Quadrangle (Faulds et al., 2011). Patua lies near the margin between the Basin and Range province, which is characterized by west-northwest directed extension and the Walker Lane province, characterized by west-northwest directed dextral shear. As such, the Patua area likely has been affected by tectonic stress associated with either or both of stress regimes over geologic time. In order to characterize this stress variation we calculated slip tendency at Patua for both normal faulting and strike slip faulting stress regimes. Based on examination of regional and local stress data (as explained above) we applied at shmin direction of 105 to Patua. Whether the vertical stress (sv) magnitude is larger than th...

15 GEOTHERMAL ENERGY↗

Gulf of Mexico miocene CO₂ site characterization mega transect

This project characterized the Miocene-age sub-seafloor stratigraphy in the near-offshore portion of the Gulf of Mexico adjacent to the Texas coast. The large number of industrial sources of carbon dioxide (CO₂) in coastal counties and the high density of onshore urbanization and environmentally sensitive areas make this offshore region extremely attractive for long-term storage of carbon dioxide emissions from industrial sources (CCS). The study leverages dense existing geologic data from decades of hydrocarbon exploration in and around the study area to characterize the regional geology for suitability and storage capacity. Primary products of the study include: regional static storage capacity estimates, sequestration “leads” and prospects with associated dynamic capacity estimates, experimental studies of CO₂-brine-rock interaction, best practices for site characterization, a large-format ‘Atlas’ of sequestration for the study area, and characterization of potential fluid migration pathways for reducing storage risks utilizing novel high-resolution 3D (HR3D) seismic surveys. In addition, three subcontracted studies address source-to-sink matching optimization, offshore well bore management and environmental aspects. The various geologic data and interpretations are integrated and summarized in a series of cross-sections and maps, which represent a primary resource for any near-term commercial deployment of CCS in the area. The regional study characterized and mapped important geologic features (e.g., Clemente-Tomas fault zone, the regionally extensive Marginulina A and Amphistegina B confining systems, etc.) that provided an important context for regional static capacity estimates and specific sequestration prospects of the study. A static capacity estimate of the majority of the Study area (14,467 mi 2 ) was estimated at 86 metric Gigatonnes. While local capacity estimates are likely to be lower due to reservoir-scale characteristics, the offshore Miocene interval is a storage resource of National interest for providing CO₂ storage as an atmospheric emissions abatement strategy. The natural petroleum system was used as an analog to infer seal quality and predict possible migration pathways of fluids in an engineered system of anthropogenic CO₂ injection and storage. The regional structural features (e.g., Clemente-Tomas fault zone) that exert primary control on the trapping and distribution of Miocene hydrocarbons are expected to perform similarly for CCS. Industrial-scale CCS will require storage capacity utilizing well-documented Miocene hydrocarbon (dominantly depleted gas) fields and their larger structural closures, as well as barren (unproductive, brine-filled) closures. No assessment was made of potential for CO₂ utilization for enhanced oil and gas recovery. The use of 3D numerical fluid flow simulations have been used in the study to greatly assist in characterizing the potential storage capacity of a specific reservoir. Due to the complexity of geologic systems (stratigraphic heterogeneity) and inherent limitations on producing a 3D geologic model, these simulations are typically simplified scenarios that explore the influence of model property variability (sensitivity study). A specific site offshore San Luis Pass (southern Galveston Island) was undertaken successfully, indicating stacked storage potential. Downscaling regional capacity estimates to the local scale (and the inverse) has proven challenging, and remains an outstanding gap in capacity assessments. In order to characterize regional seal performance and identify potential brine and CO₂ leakage pathways, results from three high-resolution 3D (HR3D) seismic datasets acquired by the study using novel HR3D (P-Cable) acquisition system showed steady and significant improvements in data quality because of improved acquisition and processing technique. Finely detailed faults and stratigraphy in the shallowest 1000 milliseconds (~800 m) of data allowed for the identification and mapping of unconformable surfaces including what is probably a surface associated with the last Pleistocene glacial lowstand. The identification of a previously unrecognized (in commercial seismic data) gas chimney that was clearly defined in the 2013 HR3D survey, indicates that HR3D surveys may be useful as both a characterization tool for the overburden of a potential carbon sequestration site and as an additional monitoring tool for future engineered injection sites. Geochemical modeling indicated that injection of CO₂ would result in minor dissolution of calcite, K-feldspar and albite. In addition, modeling of typical brines in Miocene age rocks indicate that approximately 5% of injection capacity would result from CO₂ dissolution into the brine. After extensive searches, no rock samples of the Marginulina A and Amphistegina B seals (“caprocks”) were obtained, but analyses of available core samples of other Miocene age mudrocks (seals or caprocks) indicate that they have sealing ability sufficient for potential CO 2 storage in underlying sandstone units.

01 COAL, LIGNITE, AND PEAT↗

Tidal triggering of earthquakes suggests poroelastic behavior on the San Andreas Fault

Tidal triggering of earthquakes is hypothesized to provide quantitative information regarding the fault's stress state, poroelastic properties, and may be significant for our understanding of seismic hazard. To date, studies of regional or global earthquake catalogs have had only modest successes in identifying tidal triggering. We posit that the smallest events that may provide additional evidence of triggering go unidentified and thus we developed a technique to improve the identification of very small magnitude events. We identify events applying a method known as inter-station seismic coherence where we prioritize detection and discrimination over characterization. Here we show tidal triggering of earthquakes on the San Andreas Fault. We find the complex interaction of semi-diurnal and fortnightly tidal periods exposes both stress threshold and critical state behavior. Lastly, our findings reveal earthquake nucleation processes and pore pressure conditions – properties of faults that are difficult to measure, yet extremely important for characterizing earthquake physics and seismic hazards.

58 GEOSCIENCES↗

A complete electrical hazard classification system and its application

The Standard for Electrical Safety in the Workplace, NFPA 70E, and relevant OSHA electrical safety standards evolved to address the hazards of 60-Hz power that are faced primarily by electricians, linemen, and others performing facility and utility work. This leaves a substantial gap in the management of electrical hazards in Research and Development (R&D) and specialized high voltage and high power equipment. Examples include lasers, accelerators, capacitor banks, electroplating systems, induction and dielectric heating systems, etc. Although all such systems are fed by 50/60 Hz alternating current (ac) power, we find substantial use of direct current (dc) electrical energy, and the use of capacitors, inductors, batteries, and radiofrequency (RF) power. The electrical hazards of these forms of electricity and their systems are different than for 50160 Hz power. Over the past 10 years there has been an effort to develop a method of classifying all of the electrical hazards found in all types of R&D and utilization equipment. Examples of the variation of these hazards from NFPA 70E include (a) high voltage can be harmless, if the available current is sufficiently low, (b) low voltage can be harmful if the available current/power is high, (c) high voltage capacitor hazards are unique and include severe reflex action, affects on the heart, and tissue damage, and (d) arc flash hazard analysis for dc and capacitor systems are not provided in existing standards. This work has led to a comprehensive electrical hazard classification system that is based on various research conducted over the past 100 years, on analysis of such systems in R&D, and on decades of experience. Initially, national electrical safety codes required the qualified worker only to know the source voltage to determine the shock hazard. Later, as arc flash hazards were understood, the fault current and clearing time were needed. These items are still insufficient to fully characterize all types of electrical hazards. The new comprehensive electrical hazard classification system uses a combination of voltage, shock current available, fault current available, power, energy, and waveform to classify all forms of electrical hazards. Based on this electrical hazard classification system, many new tools have been developed, including (a) work controls for these hazards, (b) better selection of PPE for R&D work, (c) improved training, and (d) a new Severity Ranking Tool that is used to rank electrical accidents and incidents with various forms of electrical energy.

57↗

Fault detection and diagnosis using neural network approaches

Neural networks can be used to detect and identify abnormalities in real-time process data. Two basic approaches can be used, the first based on training networks using data representing both normal and abnormal modes of process behavior, and the second based on statistical characterization of the normal mode only. Given data representative of process faults, radial basis function networks can effectively identify failures. This approach is often limited by the lack of fault data, but can be facilitated by process simulation. The second approach employs elliptical and radial basis function neural networks and other models to learn the statistical distributions of process observables under normal conditions. Analytical models of failure modes can then be applied in combination with the neural network models to identify faults. Special methods can be applied to compensate for sensor failures, to produce real-time estimation of missing or failed sensors based on the correlations codified in the neural network.

Kramer, Mark A.↗

Geomechanical characterization of Rock Valley carbonates

In Rock Valley, Nevada, the USA, past earthquake sequences and shallow faulting in Paleozoic carbonates remain poorly understood. Carbonates are typically more ductile rocks that do not experience large stress drops or fracture coalescence, which contradicts previous observations in the region. As part of the Source Physics Experiment, an effort has been made to experimentally characterize the petrophysical and geomechanical properties of carbonates from Rock Valley. Well core and outcrop samples were used to determine the difference between shallow-buried Tertiary limestones and deeply buried Paleozoic limestones and dolostones. The carbonates possessed porosities between 3 and 9%, with V P and V S in the Tertiary carbonates around 2700 and 1800 m/s, respectively, and 6000 and 3100 m/s, respectively, in the Paleozoic carbonates. Microstructural characterization revealed that the Paleozoic carbonates contained significantly more pre-existing damage and alteration than the Tertiary carbonates, though the deformation varies from localized to diffuse. Unconfined Brazilian tests and triaxial tests with confining pressures between 0 and 50 MPa showed that, although samples all experienced failure, the dolostones typically failed at greater stresses and possessed greater E/ν ratios than the limestones. Furthermore, the Hoek–Brown failure criterion was used to construct failure envelopes with the compressive and tensile failure tests. Velocity, density, and porosity measurements were used to construct a hypothetical velocity-depth profile and compare the results with the theoretical petrophysical measurements. Using brittleness analysis, the likely failure conditions were determined to be low-porosity dolomitic rock for fault nucleation in the Paleozoic basement.

Brittleness↗

Fault Injection and Monitoring Capability for a Fault-Tolerant Distributed Computation System

The Configurable Fault-Injection and Monitoring System (CFIMS) is intended for the experimental characterization of effects caused by a variety of adverse conditions on a distributed computation system running flight control applications. A product of research collaboration between NASA Langley Research Center and Old Dominion University, the CFIMS is the main research tool for generating actual fault response data with which to develop and validate analytical performance models and design methodologies for the mitigation of fault effects in distributed flight control systems. Rather than a fixed design solution, the CFIMS is a flexible system that enables the systematic exploration of the problem space and can be adapted to meet the evolving needs of the research. The CFIMS has the capabilities of system-under-test (SUT) functional stimulus generation, fault injection and state monitoring, all of which are supported by a configuration capability for setting up the system as desired for a particular experiment. This report summarizes the work accomplished so far in the development of the CFIMS concept and documents the first design realization.

Torres-Pomales, Wilfredo↗

Rupture Dynamics Simulations of Shallow Crustal Earthquakes on Reverse Slip Faults

The main goal of this study was to perform dynamic rupture simulations in order constrain the characterization of kinematic rupture models implemented in techniques for simulating strong ground motion for crustal earthquakes. First, we investigated the rupture process of the 2008 Iwate-Miyagi Nairiku earthquake by developing a dynamic rupture model on a reverse fault using a trial-and-error technique that produced a slip distribution and near-fault ground motion that matched the recorded ones. The simulations were performed in the frequency range 0-2 Hz, using a 3D staggered grid finite-difference method and a linear slip weakening friction law. Constrained by the observed slip distribution and consistent with dynamic rupture models, the derived kinematic rupture model of the Iwate-Miyagi Nairiku earthquake contains areas with relatively large slip rate, representing strong motion generation areas, set against lower amplitude heterogeneous background slip, and a relatively low slip rate in the weak zone of the top-most crust (upper 3km). Second, we performed rupture dynamics modeling to constrain shallow slip characterization in rupture models for strike-slip crustal earthquakes. The objective was to establish general rules about the characterization of slip rate function and slip at shallow depths and in the strong motion generation areas (SMGAs). The simulations of spontaneous rupture were performed in the frequency range 0-2.0Hz, using a 3D staggered-grid finite-difference method and a layer over half-space 1D crustal velocity model with a minimum shear-wave velocity of 2.8 km/s. In order to account for changes in material ductility and reduction of stress drop, observed in the shallow crust (upper 3-5 km), and the transition from ductile state to brittle state in the upper seismogenic zone, in our stress models we included a shallow weak zone (<4km). In this zone the stress drop was set to zero at the free surface and gradually increased with depth, while the slip weakening distance was set to 75 cm at the free surface and decreased to 50 cm at the base of the weak zone. As in the case of reverse faulting during the Iwate-Miyagi Nairiku earthquake, from these computations we found a systematic change in the shape of the slip-rate function, from Kostrov-type in the deeper part of the fault to a more symmetric cosine-type in the upper few kilometers, near the free-surface. Moreover, the average slip duration in the weak zone, with respect to slip duration in the deeper parts of the fault, increases by at most a factor of 1.5. We found a systematic and gradual change in the shape of the slip-rate function from Kostrov-type in the asperity areas (SMGAs), to more symmetric cosine-type in the upper few km near the free-surface, on the long period motion generation area (LMGA). The effective rise time in the LMGA, with respect to that in the SMGAs, increases by at most a factor of 2. Effective rise time is the time difference between the time at which the slip rate drops to a level that is equal to 25% of its peak and the onset time of the signal. In addition, the slip in the LMGA located above the SMGAs is almost the same as the one in the SMGAs, and about 1.5 times larger than the average slip.

58 GEOSCIENCES↗

Solar Dynamics Observatory Guidance, Navigation, and Control System Overview

The Solar Dynamics Observatory (SDO) was designed and built at the Goddard Space Flight Center, launched from Cape Canaveral on February 11, 2010, and reached its final geosynchronous science orbit on March 16, 2010. The purpose of SDO is to observe the Sun and continuously relay data to a dedicated ground station. SDO remains Sun-pointing throughout most of its mission for the instruments to take measurements of the Sun. The SDO attitude control system (ACS) is a single-fault tolerant design. Its fully redundant attitude sensor complement includes sixteen coarse Sun sensors (CSSs), a digital Sun sensor (DSS), three two-axis inertial reference units (IRUs), and two star trackers (STs). The ACS also makes use of the four guide telescopes included as a part of one of the science instruments. Attitude actuation is performed using four reaction wheels assemblies (RWAs) and eight thrusters, with a single main engine used to provide velocity-change thrust for orbit raising. The attitude control software has five nominal control modes, three wheel-based modes and two thruster-based modes. A wheel-based Safehold running in the attitude control electronics box improves the robustness of the system as a whole. All six modes are designed on the same basic proportional-integral-derivative attitude error structure, with more robust modes setting their integral gains to zero. This paper details the final overall design of the SDO guidance, navigation, and control (GN&C) system and how it was used in practice during SDO launch, commissioning, and nominal operations. This overview will include the ACS control modes, attitude determination and sensor calibration, the high gain antenna (HGA) calibration, and jitter mitigation operation. The Solar Dynamics Observatory mission is part of the NASA Living With a Star program, which seeks to understand the changing Sun and its effects on the Solar System, life, and society. To this end, the SDO spacecraft carries three Sun-observing instruments: Helioseismic and Magnetic Imager (HMI), led by Stanford University; Atmospheric Imaging Assembly (AIA), led by Lockheed Martin Space and Astrophysics Laboratory; and Extreme Ultraviolet Variability Experiment (EVE), led by the University of Colorado. The basic mission is to observe the Sun for a very high percentage of the 5-year mission (10-year goal) with long stretches of uninterrupted observations and with constant, high-data-rate transmission to a dedicated ground station to be located in White Sands, New Mexico. These goals guided the design of the spacecraft bus that will carry and service the three-instrument payload. Overarching design goals for the bus are geosynchronous orbit, near-constant Sun observations with the ability to fly through eclipses, and constant HGA contact with the dedicated ground station. A three-axis stabilized ACS is needed both to point at the Sun accurately and to keep the roll about the Sun vector correctly positioned with respect to the solar north pole. This roll control is especially important for the magnetic field imaging of HM I. The mission requirements have several general impacts on the ACS design. Both the AIA and HMI instruments are very sensitive to the blurring caused by jitter. Each has an image stabilization system (ISS) with some ability to filter out high frequency motion, but below the bandwidth of the ISS the control system must compensate for disturbances within the ACS bandwidth or avoid exciting jitter at higher frequencies. Within the ACS bandwidth, the control requirement imposed by AIA is to place the center of the solar disk no more than 2 arc sec, 3 , from a body-defined target based on one of the GTs that accompany the instrument. This body-defined target, called the science reference boresight (SRB), was determined from the postlaunch orientation of the GTs by averaging the bounding telescope boresights for pitch to get a pitch SRB coordinate, and by averaging the bounding boresights for yaw toet the yaw SRB coordinate. The location of this SRB in the 0.5-deg field-of-view for each GT then becomes the central target for each telescope; one GT is selected for use as the ACS controlling guide telescope (CGT) at any given time. Fine Sun-pointing is effected based on this SRB for all three instruments when the Sun is within the linear range of the CGT. In addition to limiting jitter, HMI science requires averaging several observations, making the instrument sensitive to low frequency motion that induces differential motion between each observation. This requires the spacecraft attitude to be stable about the roll axis to approximately 10 arcsec over a ten-minute period. Instrument calibrations require that the spacecraft point the SRB up to 2.5 degrees in pitch and yaw away from the center of the Sun, placing the Sun outside the field-of-view of the guide telescopes. In such instances, when the GTs cannot provide the definitive target for the ACS, on-board attitude determination combined with ephemeris prediction of the Sun direction must provide the definitive target. EVE is capable of observing the Sun with less dependence on attitude control. However, the ground data processing needs for calibrations result in the most strict attitude knowledge requirements for the mission: [35,70,70] arcsec, 3 , of knowledge with respect to the center of the solar disk. In addition to driving the ACS sensor selection, the knowledge requirements, which have their effect primarily during Inertial mode calibrations, drive the accuracy requirements for the solar ephemeris. The need to achieve and maintain geosynchronous orbit (GEO) drove the need for high-efficiency propulsive systems and appropriate attitude control. The main engine provided high specific impulse for the maneuvers to attain GEO, while the smaller ACS thrusters managed the disturbance torques of the larger engine and provided the capability for much smaller adjustment burns on orbit. SDO s large solar profile means that solar radiation pressure is a large torque disturbance, and the momentum buildup from this disturbance and the GEO altitude drives the ACS to use thrusters to manage vehicle momentum. The demanding data capture budget for the mission, however, requires SDO to avoid frequent thruster maneuvers, while concerns about on-orbit jitter restrict the maximum desired wheel speeds desired from the RWAs. The plan for on-orbit wheel speed and momentum management will be discussed as well as what is now being done in operation after the jitter environment was characterized. The SDO ACS hardware complement is single-fault tolerant. Two main processors carry virtually identical copies of the command and data handling and ACS software, and two identical attitude control electronics (ACE) boxes carry Coldfire processors with contingency ACS software and other hardware interface cards; the ACE structure allows reaction wheels to be commanded by the Sun-pointing Safehold independent of the Mil Std 1553 data bus. The sixteen Adcole CSSs are grouped into primary and backup sets of eight sensors, each set providing the ability to calculate a sun vector. Each set of eight eyes provides full 4 -steradian coverage. The Adcole DSS comprises an optics head and a separate electronics box providing a 1553 data interface. The electronics box is mounted inside the Faraday cage created by the spacecraft bus module. The DSS head with its 32- deg square FOV is mounted on the instrument module with its boresight along the spacecraft X axis, nearly aligned with the Sun during observations. Adcole has designed the DSS calibration parameters so that the accuracy is 0.24 arcminutes within 10 deg of the boresight, and diminishes to 3 arcminutes as the Sun moves towards the edges of its FOV . This DSS calibration scheme provides higher accuracy attitude determination over the range of the instrument calibration maneuvers.

Morgenstern, Wendy M.↗

Dislocation model for aseismic crustal deformation at Hollister, California

A model of crustal deformation during the interseismic phase is developed and applied (using the improved Bayesian inversion algorithm described by Jackson and Matsu'ura, 1985) to trilateration data for the USGS Hollister (CA) network. In the model, rigid blocks in motion relative to each other experience friction only in a brittle upper zone, while their ductile lower zones slide freely; the Hollister model comprises five blocks and nine rectangular fault patches. The data and results are presented in tables, graphs, and maps and characterized in detail. The model predicts steady block motion on time scales between 10 yr and 1 Myr, with net motion across the San Andreas/Calaveras fault system 38 + or - 3 mm/yr and brittle/ductile transition depths ranging from 0.4 to 11 km. Two San Andreas segments with higher probabilities of moderate-to-large earthquakes are identified.

Matsuura, Mitsuhiro↗

Uncertain quantum computing futures and potential energy and physical resource impacts at scale

Considerable attention has recently focused on the vast energy and water demands of supercomputing, namely large-scale data centers that underpin artificial intelligence (AI), one of the great disruptors of contemporary society. Looking ahead some years from now, quantum computing is poised to disrupt established computing paradigms once again. Scientists and engineers are now working intensely to bring this century-old dream of physicists to fruition. Yet, as quantum computers begin to be integrated with classical supercomputing architectures, the implications for energy and physical resource use also need to be understood, especially how they compare to today’s AI data centers. These impacts have not yet been quantified by the research community – a notable gap in the literature, even if commercial-scale deployment of Quantum-Accelerated Computing Infrastructure (QuACI) is not expected for a few more years. This study is the first to conduct such an assessment. Using publicly available information from academic sources and private industry, we characterize multiple configurations of superconducting qubit-based, fault-tolerant quantum computers (FTQC) that could plausibly be deployed at scale in the 2030s and into the 2040s. By parameterizing these FTQC systems at a process level, we conduct a prospective scenario analysis to quantify their energy and physical resource needs. While these estimates are uncertain, given the current state of quantum technologies and their unknown future trajectories, important insights can already be drawn. One key finding is that while the electricity needs for a fleet of FTQCs are within the bounds of previous modeling studies that have explored high electricity demand futures, the needs for certain physical resources, namely water and helium-3, could pose bottlenecks to QuACI scale-up.

Computing↗

Time-resolved correlative optical microscopy of charge-carrier transport, recombination, and space-charge fields in CdTe heterostructures

From time- and spatially resolved optical measurements, we show that extended defects can have a large effect on the charge-carrier recombination in II-VI semiconductors. In CdTe double heterostructures grown by molecular beam epitaxy on the InSb (100)-orientation substrates, we characterized the extended defects and found that near stacking faults the space-charge field extends by 2-5 μm. Charge carriers drift (with the space-charge field strength of 730-1,360 V cm -1 ) and diffuse (with the mobility of 260 ± 30 cm 2 V -1 s -1 ) toward the extended defects, where the minority-carrier lifetime is reduced from 560 ns to 0.25 ns. Furthermore, the extended defects are nonradiative recombination sinks that affect areas significantly larger than the typical crystalline grains in II-VI solar cells. From the correlative time-resolved photoluminescence and second-harmonic generation microscopy data, we developed a band-diagram model that can be used to analyze the impact of extended defects on solar cells and other electronic devices.

14 SOLAR ENERGY↗

Geometric Structure and Transversal Logic of Quantum Reed–Muller Codes

Designing efficient and noise-tolerant quantum computation protocols generally begins with an understanding of quantum error-correcting codes and their native logical operations. The simplest class of native operations are transversal gates, which are naturally fault-tolerant. Here, in this paper, we aim to characterize the transversal gates of quantum Reed–Muller (RM) codes by exploiting the well-studied properties of their classical counterparts. We start our work by establishing a new geometric characterization of quantum RM codes via the Boolean hypercube and its associated subcube complex. More specifically, a set of stabilizer generators for a quantum RM code can be described via transversal X and Z operators acting on subcubes of particular dimensions. This characterization leads us to define subcube operators composed of single-qubit π/2 k Z -rotations that act on subcubes of given dimensions. We first characterize the action of subcube operators on the code space: depending on the dimension of the subcube, these operators either (1) act as a logical identity on the code space, (2) implement non-trivial logic, or (3) rotate a state away from the code space. Second, and more remarkably, we uncover that the logic implemented by these operators corresponds to circuits of multi-controlled-Z gates that have an explicit and simple combinatorial description. Overall, this suite of results yields a comprehensive understanding of a class of natural transversal operators for quantum RM codes.

Reed–Muller (RM) codes↗