Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fuel Cell”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

The influence of electrode crack dimensions on the durability of polymer electrolyte membrane fuel cells

Electrode cracks in polymer electrolyte membrane fuel cells (PEMFCs) are correlated with early onset failures. Here, in this work we investigate the influence of cracked gas diffusion electrodes (GDEs) on the durability of the membrane electrode assembly (MEA) using a combined chemical-mechanical accelerated stress test (AST). Electrode crack dimensions were systematically tuned using ink formulations and material selection strategies. A parameter to describe the crack width areal density (Φ CW ) was used to quantify the degree of discontinuity in the electrode surfaces. Open circuit voltage (OCV) transient analyses were used to benchmark and characterize the failure mechanisms in the MEAs as a function of the Φ CW . While smaller electrode-level cracks, on the order of microns, yielded a 28 % decrease in operating lifetime, larger cracks that propagated from a discontinuous, microporous layer (MPL) coating, decreased the operating lifetime by 56 %. This work emphasizes the need for material processing strategies that consider defect tolerances to limit membrane failures in PEMFCs.

08 HYDROGEN↗

Revealing in-plane movement of platinum in polymer electrolyte fuel cells after heavy-duty vehicle lifetime

Fuel cell heavy-duty vehicles (HDVs) require increased durability of oxygen-reduction-reaction electrocatalysts, making knowledge of realistic degradation mechanisms critical. Here identical-location micro-X-ray fluorescence spectroscopy was performed on membrane electrode assemblies. The results exposed heavy in-plane movement of electrocatalyst after HDV lifetime, suggesting that electrochemical Ostwald ripening may not be a local effect. Development of local loading hotspots and preferential movement of electrocatalyst away from cathode catalyst layer cracks was observed. The heterogeneous degradation exhibited by a modified cathode gas diffusion layer membrane electrode assembly after HDV lifetime was successfully quantified by the identical-location approach. Further synchrotron micro-X-ray diffraction and micro-X-ray fluorescence experiments were performed to obtain the currently unknown correlation between electrocatalyst nanoparticle size increase and loading change. A direct correlation was discovered which developed only after HDV lifetime. Finally, the work provides a route to engineer immediate system-level mitigation strategies and to develop structured cathode catalyst layers with durable electrocatalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Low Cost, Robust and Durable Cathode Materials to Support Solid Oxide Fuel Cell Commercialization (Final Technical Report)

The project is aimed at addressing critical issues related to chromia-poisoning in the cathode of solid oxide fuel cells. A technical hurdle to the commercialization of solid oxide fuel cells is that chromia sources from the metallic interconnect and the balance of plant (BoP) components will cause chromia-poisoning to the cathode performance. This presents a significant challenge since it is very difficult to eliminate chromia sources in the cathode environment. One aspect of the current project is to evaluate whether SFM (Sr 2 Fe 1.5 Mo 0.5 O 6-δ ) that we have recently developed as redox-stable mixed conducting oxide possesses tolerance to chromia-poisoning. The second focus of this project is to evaluate coating on the cathode materials to mitigate chromia poisoning effect. Both thermodynamic evaluation and experimental approaches have been applied to enhance the knowledge base and fundamental understanding of chromia-tolerance of cathode for solid oxide fuel cells. low cost, robust and durable cathode material to support SOFC commercialization.

30 DIRECT ENERGY CONVERSION↗

Multi-Scale Modeling of Hydrogen Transport in a Porous Fuel Cell Anode

Proton-exchange-membrane fuel cells (PEMFC) are a clean energy conversion alternative to traditional fossil-fuel combustion; however, transport resistances in the electrode pose a lower-limit to catalyst loading and commercialization of PEMFCs. PEMFCs consist of simultaneous hydrogen (H 2 ) oxidation and oxygen (O 2 ) reduction at the anode and cathode, respectively. Here, while oxygen transport resistances in PEMFCs have been widely studied both experimentally and analytically, hydrogen transport resistances are less understood. Herein, we present a physics-based model that encompasses multi-scale transport within the anode side of the PEMFC. The O 2 in the cathode here is omitted and replaced with H 2 to deconvolute O 2 transport resistance contributions, similar to that of a hydrogen pump. Replication of the hydrogen pump setup allows for comparison of the model against experimental analysis of H 2 gas-transport resistance in H 2 limiting-current experiments, which can also inform gas transport (including oxygen) in general. Herein, we present a multi-scale analytical model of the porous anode catalyst layers and individual catalyst agglomerates that enables determination of the effects of electrode morphology such as agglomerate size, catalyst loading, etc. on H 2 transport resistance through the porous electrode to complement and better understand H 2 limiting current experiments and deconvolute local H 2 transport resistances.

Zhang, Rosa↗

A low temperature unitized regenerative fuel cell realizing 60% round trip efficiency and 10 000 cycles of durability for energy storage applications

Unitized regenerative fuel cells (URFC) convert electrical energy to and from chemical bonds in hydrogen. URFCs have the potential to provide economical means for efficient long-term, seasonal, energy storage and on-demand conversion back to electrical energy. We first optimize the catalyst layer for discrete electrolyzer and fuel cell and then configure the URFC. The goal is to identify a cost competitive configuration for URFCs, and demonstrate it in terms of upper limit of round trip efficiencies (RTEs). Two possible configurations of URFCs are compared via experiments and techno-economic analysis (TEA), which emphasize the advantages of the unconventional constant-electrode (CE) URFC over the traditional constant-gas (CG) configuration. We also study the stability via accelerated stress tests (ASTs) and demonstrate steady state operation in a daily cycle for day to night energy shifting. From the investigations, the optimum composition of the URFC anode catalyst layer is 90 at% Ir-black balanced by Pt-black for both CE and CG configurations. At 80 °C and 1 A cm -2 , the optimized CE URFC achieves 57% and 60% RTE with air and O 2 as the reductant gases, respectively. We then evaluated the differences in durability using an AST over 10k charge–discharge cycles; the results reveal that the wider potential window at the anode in CE (0.05–1.55 V) has minimal effect on catalyst layer stability compared to CG (0.55–1.55 V). Furthermore, there was no degradation up to the range of 2k–5k cycles; beyond that the fuel cell (discharge) performance degraded while the electrolyzer (charge) performance was still stable. Finally, the observations here indicate substantial potential to employ URFCs as efficient and cost-effective bidirectional energy-conversion devices within energy storage and utilization systems after appropriate technological and operational optimizations.

25 ENERGY STORAGE↗

Using operando techniques to understand and design high performance and stable alkaline membrane fuel cells

There is a need to understand the water dynamics of alkaline membrane fuel cells under various operating conditions to create electrodes that enable high performance and stable, long-term operation. Here we show, via operando neutron imaging and operando micro X-ray computed tomography, visualizations of the spatial and temporal distribution of liquid water in operating cells. We provide direct evidence for liquid water accumulation at the anode, which causes severe ionomer swelling and performance loss, as well as cell dryout from undesirably low water content in the cathode. We observe that the operating conditions leading to the highest power density during polarization are not generally the conditions that allow for long-term stable operation. This observation leads to new catalyst layer designs and gas diffusion layers. This study reports alkaline membrane fuel cells that can be operated continuously for over 1000 h at 600 mA cm -2 with voltage decay rate of only 32-μV h -1 – the best-reported durability to date.

25 ENERGY STORAGE↗

Migration and Precipitation of Platinum in Anion–Exchange Membrane Fuel Cells

Despite the recent progress in increasing the power generation of Anion-exchange membrane fuel cells (AEMFCs), their durability is still far lower than that of Proton exchange membrane fuel cells (PEMFCs). Using the complementary techniques of X-ray micro-computed tomography (CT), Scanning Electron Microscopy (SEM) and Energy Dispersive X-ray (EDX) spectroscopy, we have identified Pt ion migration as an important factor to explain the decay in performance of AEMFCs. In alkaline media Pt+2 ions are easily formed which then either undergo dissolution into the carbon support or migrate to the membrane. In contrast to PEMFCs, where hydrogen cross over reduces the ions forming a vertical “Pt line” within the membrane, the ions in the AEM are trapped by charged groups within the membrane, leading to disintegration of the membrane and failure. Furthermore, diffusion of the metal components is still observed when the Pt/C of the cathode is substituted with a FeCo–N–C catalyst, but in this case the Fe and Co ions are not trapped within the membrane, but rather migrate into the anode, thereby increasing the stability of the membrane.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimizing Hydrogen Fueling Infrastructure Plans on Freight Corridors for Heavy-Duty Fuel Cell Electric Vehicles

The development of a future hydrogen energy economy will require the development of several hydrogen market and industry segments including a hydrogen-based commercial freight transportation ecosystem. For a sustainable freight transportation ecosystem, the supporting fueling infrastructure and the associated vehicle powertrains making use of hydrogen fuel will need to be co-established. This article introduces the OR-AGENT (Optimal Regional Architecture Generation for Electrified National Transportation) tool developed at the Oak Ridge National Laboratory, which has been used to optimize the hydrogen refueling infrastructure requirements on the I-75 corridor for heavy-duty (HD) fuel cell electric commercial vehicles (FCEV). This constraint-based optimization model considers existing fueling locations, regional-specific vehicle fuel economy and weight, vehicle origin and destination (O-D), and vehicle volume by class and infrastructure costs to characterize in-mission refueling requirements for a given freight corridor. The authors applied this framework to determine the ideal public access locations for hydrogen refueling (constrained by existing fueling stations), the minimal viable cost to deploy sufficient hydrogen fuel dispensers, and associated equipment, to accommodate a growing population of hydrogen fuel cell trucks. The framework discussed in this article can be expanded and applied to a larger interstate system, expanded regional corridor, or other transportation network. This article is the third in a series of papers that defined the model development to optimize a national hydrogen refueling infrastructure ecosystem for HD commercial vehicles.

33 ADVANCED PROPULSION SYSTEMS↗

Performance and Durability of Hybrid Fuel Cell Systems for Class-8 Long Haul Trucks

Hybrid fuel cell-battery configurations are investigated that overcome thermal management issues in fuel cell powertrains for heavy-duty Class 8 trucks. The battery is sized so that it has sufficient capacity to provide supplemental power and energy on a hill climb transient at end-of-life. A dynamic load sharing strategy is developed to distribute the power demand between the fuel cell system (FCS) and the energy storage system in a manner that optimizes their lifetimes. The FCS end-of-life is identified as the terminal point beyond which the stack cannot generate the rated power with target power density at 0.7 V and 40 °C ambient temperature. Reaching the target lifetime with a-Pt/C cathode catalyst in one hybrid configuration requires voltage clipping to 813 mV, idle power limited to 50 kW, catalyst overloading to 0.45 mg cm -2 total Pt in anode and cathode, and 44% active membrane area oversizing. The stack and FCS drive cycle efficiencies decrease by 4.2% and 5.4%, respectively, during the electrode lifetime. Further, the FCS performance, durability and cost are compared with the targets of 68% peak efficiency, 0.30 mg cm -2 total Pt loading, 2.5 kW/g PGM Pt group metal (PGM) loading, 750 mW cm -2 power density, 25,000-h lifetime and $80/kW cost.

33 ADVANCED PROPULSION SYSTEMS↗

Understanding Direct-Ammonia Protonic Ceramic Fuel Cells: High-Performance in the Absence of Precious Metal Catalysts

Ammonia has received considerable attention as a promising carbon-free hydrogen carrier. At temperatures above 400 °C, NH 3 is thermodynamically unstable with respect to decomposition into nitrogen and hydrogen and is, thus, suitable for direct use in solid oxide fuel cells (SOFCs) without external reforming. However, poor catalytic activity for ammonia decomposition at the moderate temperatures of protonic ceramic fuel cell (PCFC) operation has resulted in low fuel cell power output relative to operation on hydrogen and likely contributes to reported cell degradation. Here we prepared cells based on a thermodynamically robust electrolyte, a high activity cathode, and an anode with a distinctive structure to overcome challenges of poor activity and stability. Furthermore, the cells delivered peak power densities of 0.59 and 0.44 W cm –2 under H 2 and NH 3 , respectively, at 500 °C, excellent stability over a period of 200 h, and no detectable NO x in the anode exhaust gas.

25 ENERGY STORAGE↗

Challenges in the designing, planning and deployment of hydrogen refueling infrastructure for fuel cell electric vehicles

Hydrogen can power transportation with near zero greenhouse gas emissions. With government support, early market development is now underway in several nations thanks to technological advances in fuel cell vehicles and electricity generation from renewable energy. Deploying a sustainable hydrogen refueling infrastructure faces methodological and practical challenges ranging from the creation of appropriate codes to managing the co-evolution of the refueling network and growth of the stock of hydrogen fuel cell vehicles. Furthermore, this paper presents a comprehensive review of the challenges facing the designing, planning and deployment of hydrogen refueling infrastructure progress to date and outlook for the future. The design and costs of refueling infrastructure as well as the lifecycle environmental effects of hydrogen vehicles depend on how hydrogen is produced and delivered to refueling stations. In recent years, important advances have been made in methods for planning the numbers, sizes and location of hydrogen stations. Institutional barriers are also gradually being overcome. Co-evolving the deployment of stations and the demand for fuel cell vehicles remains a crucial subject for future research.

33 ADVANCED PROPULSION SYSTEMS↗

A highly oxygen reduction reaction active and CO 2 durable high-entropy cathode for solid oxide fuel cells

One big obstacle for the oxygen reduction reaction (ORR) electrode in solid oxide fuel cells (SOFCs) is the poor reaction activity and fast degradations caused by CO 2 poisoning. Here, in this study, we report our design of an active A-site Ca-rich high-entropy Pr 0.1875 Ba 0.1875 Sr 0.1875 La 0.1875 Ca 0.25 CoO 3-δ (PBSLC 25 C) electrode, guided by the O p-band theory. Here, when applied as a cathode in solid oxide fuel cells (SOFCs), it demonstrates high ORR activity and excellent CO 2 tolerance under realistic operating conditions. Ni-YSZ-based anode-supported cells with PBSLC 25 C cathodes demonstrate excellent peak power densities of 1.14 W cm -2 , 1.04 W cm -2 , and 0.77 W cm -2 in the air with 1%, 5%, and 10% CO 2 , respectively, at 750 °C. The engineered high-entropy PBSLC 25 C effectively diminishes the CO 2 poisoning effect and maintains active surfaces for fast oxygen exchange, as confirmed by the cell durability test in air containing CO 2 (5 and 10 vol%), Raman spectroscopy, and density functional theory calculations.

30 DIRECT ENERGY CONVERSION↗

Machine learning-based surrogate models and transfer learning for derivative free optimization of HT-PEM fuel cells

Widespread adoption of high-temperature polymer electrolyte membrane electrochemical systems, such as fuel cells (HT-PEMFCs), requires models and computational tools for accurate optimization and guiding new materials for enhancing performance and durability. In this contribution, knowledge-based modelling and data-driven modelling are combined using Few-Shot Learning and implementing an Automated Machine Learning framework for the generation of Machine Learning-based surrogate models. Applicability of the resulting model for derivative-free optimization is demonstrated. Additionally, a way of considering extrapolation in the optimization task is presented. Results show that although extrapolation is needed to achieve better solutions during optimization, it can be monitored and managed. As a result, tuning the electrode ionomer binder's properties, such as ionic conductivity, in the fuel cell represents a promising pathway for improving HT-PEMFC performance.

08 HYDROGEN↗

Modeling Synergistic Fuel Cell Membrane Degradation with Mitigating Effects of Cerium

During operation, polymer-electrolyte-membrane (PEM) fuel cells undergo mechanical and chemical degradation mechanisms, which behave synergistically and lead to accelerated membrane degradation over time. This study builds upon previous modeling work on mechanical degradation as described by a pinhole in the membrane and the effects of cerium on chemical degradation.1 By combining these two models, analysis can be carried out on the coupled degradation methods and how the mitigation effects of cerium disrupt the degradation cycle. The mechanical model represents a pinhole in the membrane using an effective void fraction, which allows for increased gas crossover through the membrane and impacts the membrane transport and mechanical properties. A microkinetic model for the chemical degradation is included in the model, including attack of the membrane polymer by hydroxyl radicals as well as the mitigation reaction for quenching of hydroxyl radicals with cerium. A concentrated solution theory approach is used to model the transport of cerium ions throughout the cell.2 The model results show how the location of cerium in the cell can be used to prevent chemical degradation. In addition, the model shows how cerium slows down the rate of pinhole growth by reducing the gas crossover and membrane thinning rate. Finally, the model can be used to optimize the distribution of cerium in the membrane and catalyst layers by balancing trade-offs between lowering degradation rates and decreasing fuel cell performance.

25 ENERGY STORAGE↗

Understanding how single-atom site density drives the performance and durability of PGM-free Fe–N–C cathodes in anion exchange membrane fuel cells

One of the most important needs for the future of low-cost fuel cells is the development of highly active platinum group metal (PGM)-free catalysts. For the oxygen reduction reaction, Fe–N–C materials have been widely studied in both acid and alkaline media. However, reported catalysts in the literature show quite different intrinsic activity and in-cell performance, despite similar synthesis routes and precursors. Here, two types of Fe–N–C are prepared from the same precursor and procedure – the main difference is how the precursor was handled prior to use. It is shown that in one case Fe overwhelmingly existed as highly active single-metal atoms in FeN4 coordination (preferred), while in the other case large Fe particles coexisting with few single metal atoms were obtained. As a result, there were drastic differences in the catalyst structure, activity, and especially in their performance in an operating anion exchange membrane fuel cell (AEMFC). Additionally, it is shown that catalyst layers created from single-atom-dominated Fe–N–C can have excellent performance and durability in an AEMFC using H 2 /O 2 reacting gases, achieving a peak power density of 1.8 W cm -2 – comparable to similar AEMFCs with a Pt/C cathode – and being able to operate stably for more than 100 h. Finally, the Fe–N–C cathode was paired with a low-loading PtRu/C anode electrode to create AEMFCs (on H 2 /O 2 ) with a total PGM loading of only 0.135 mg cm -2 (0.090 mg Pt cm -2 ) that was able to achieve a very high specific power of 8.4 W mg PGM -1 (12.6 W mg Pt< sup>-1 ).

36 MATERIALS SCIENCE↗

Ethanol internal reforming in solid oxide fuel cells: A path toward high performance metal-supported cells for vehicular applications

Internal reforming of ethanol fuel was explored on high-performance metal-supported solid oxide fuel cells (MS-SOFCs) with infiltrated catalysts. The hydrogen concentration and internal reforming effects were evaluated systematically with different fuels including: hydrogen, simulated reformate, anhydrous ethanol, ethanol water blend, and hydrogen-nitrogen mixtures. A simple infiltration of Ni reforming catalyst into 40 vol.% Ni-Sm 0.20 Ce 0.80 O 2-δ (Ni-SDCN 40 ) and fuel-side metal support leads to complete internal reforming, as validated by comparison to simulated reformate. The performance difference between hydrogen and fully-reformed ethanol is attributed entirely to decrease in hydrogen concentration. High peak power density was achieved for a range of conditions, for example 1.0 W cm -2 at 650 °C in ethanol-water blend, and 1.4 W cm -2 at 700 °C in anhydrous ethanol fuel. Initial durability tests with ethanol-water blend show promising stability for 100 hours at 700 °C and 0.7 V. Carbon is not deposited in the Ni-SDCN 40 anode during operation.

25 ENERGY STORAGE↗

Performance-Limiting Factors of Hydrocarbon Ionomeric Binders for Fuel Cells and Electrolyzers

Here, the move toward nonfluorinated hydrocarbon ionomers for fuel cells and electrolyzers is driven by potential restrictions on polyfluoroalkyl substances such as Nafion. This study examines the key limitations of hydrocarbon ionomers through half- and single-cell experiments with model hydrocarbon ionomers. Half-cell tests reveal three major performance barriers: undesirable adsorption, electrochemical oxidation, and low gas permeability. Competitive sulfate adsorption helps counteract ionomer adsorption and oxidation. These findings align with single-cell performance data, which further reveal additional oxygen mass transport limitations likely caused by localized electrode flooding. Together, these findings offer valuable insights to guide the development of high-performance, fluorine-free hydrocarbon ionomers for next-generation fuel cells and electrolyzers.

Choi, Jong-Ho [Los Alamos National Laboratory (LAN↗