Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

On-Site Inspection RadioIsotopic Spectroscopy (Osiris) System Development

We have designed and tested hardware and software for the acquisition and analysis of high-resolution gamma-ray spectra during on-site inspections under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The On-Site Inspection RadioIsotopic Spectroscopy—Osiris—software filters the spectral data to display only radioisotopic information relevant to CTBT on-site inspections, e.g.,132I. A set of over 100 fission-product spectra was employed for Osiris testing. These spectra were measured, where possible, or generated by modeling. The synthetic test spectral compositions include non-nuclear-explosion scenarios, e.g., a severe nuclear reactor accident, and nuclear-explosion scenarios such as a vented underground nuclear test. Comparing its computer-based analyses to expert visual analyses of the test spectra, Osiris correctly identifies CTBT-relevant fission product isotopes at the 95% level or better.The Osiris gamma-ray spectrometer is a mechanically-cooled, battery-powered ORTEC Transpec-100, chosen to avoid the need for liquid nitrogen during on-site inspections. The spectrometer was used successfully during the recent 2014 CTBT Integrated Field Exercise in Jordan. The spectrometer is controlled and the spectral data analyzed by a Panasonic Toughbook notebook computer. To date, software development has been the main focus of the Osiris project. In FY2016-17, we plan to modify the Osiris hardware, integrate the Osiris software and hardware, and conduct rigorous field tests to ensure that the Osiris system will function correctly during CTBT on-site inspections. The planned development will raise Osiris to technology readiness level TRL-8; transfer the Osiris technology to a commercial manufacturer, and demonstrate Osiris to potential CTBT on-site inspectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structure of the Odd-Odd Nucleus {sup 188}Re

Thermal neutron capture gamma-ray spectra for {sup 187}Re(n,{gamma}){sup 188}Re reaction were measured. Singles and coincidence spectra were detected in order to develop the level scheme. The evaluation is in progress, of which the first results are obtained from the analysis of coincidence spectra, allowing to check the level scheme below 500 keV excitation energy. Seven low-energy negative parity bands are developed in order to find better energies for rotational levels. With a good confidence, a few positive parity bands are developed as well. Rotor plus two quasiparticle model calculations, employing effective matrix element method are performed for the system of six negative parity rotational bands.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of {gamma} radiation from {sup 178}Hf in the respective (n, n Prime {gamma}) reaction

The spectra and angular distributions of gamma rays were measured in the reaction {sup 178}Hf(n, n Prime {gamma}) induced by a beam of fast reactor neutrons. Data onmultipole mixtures in gamma transitions and a lot of new information about gamma transitions of energy 1.5 to 3.0 MeV were obtained. A comparison of these results with information known from the respective (n, {gamma}) reaction made it possible to refine the schemes of deexcitation of {sup 178}Hf levels at energies above 1.5 MeV, to determine more precisely features of these levels, and to introduce new levels and rotation bands at excitation energies of about 2MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of Fireworks Algorithm in Gamma-Ray Spectrum Fitting for Radioisotope Identification

We present that identification of radioisotopic signature patterns in gamma-ray spectra is of paramount importance in various applications of gamma spectroscopy. Therefore, there are several active research efforts to develop accurate and precise methods to perform automated spectroscopic analysis and subsequently recognize gamma-ray signatures. In this work, the authors present a new method for radioisotope identification in gamma-ray spectra obtained with a low resolution radiation detector. The method fits the obtained spectrum with a linear combina-tion of known template signature patterns. Coefficients of the linear combination are evaluated by computing the solution of a single objective optimization problem, whose objective is the Theil-1 inequality coefficient. Optimization of the problem is performed by the Fireworks Algorithm, which identifies a set of coefficients that minimize the Theil-1 value. The computed coefficients are statistically tested for being significantly different than zero or not, and if at least one is found to be zero then the Fireworks Algorithm is used to reiterate fitting using the non-zero templates. Fitting iterations are continued up to the point that no linear coefficients are found to be zero. The output of the method is a list that contains the radioisotopes that have been identified in the measured spectrum. The method is tested on a set of both simulated and real experimental gamma-ray spectra comprised of a variety of isotopes, and compared to a multiple linear regression fitting, and genetic algorithm Theil-1 based fitting. Finally, results demonstrate the potentiality of the Fireworks Algorithm based method, expressed as higher accuracy and similar precision over the other two tested methodologies for radioisotope signature pattern identification in the framework of gamma-ray spectrum fitting.

Theil Coefficient↗

BROADBAND STUDY OF GRB 091127: A SUB-ENERGETIC BURST AT HIGHER REDSHIFT?

GRB 091127 is a bright gamma-ray burst (GRB) detected by Swift at a redshift z = 0.49 and associated with SN 2009nz. We present the broadband analysis of the GRB prompt and afterglow emission and study its high-energy properties in the context of the GRB/SN association. While the high luminosity of the prompt emission and standard afterglow behavior are typical of cosmological long GRBs, its low-energy release (E{sub {gamma}} < 3 Multiplication-Sign 10{sup 49} erg), soft spectrum, and unusual spectral lag connect this GRB to the class of sub-energetic bursts. We discuss the suppression of high-energy emission in this burst, and investigate whether this behavior could be connected with the sub-energetic nature of the explosion.

79 ASTRONOMY AND ASTROPHYSICS↗

Is there a low-energy enhancement in the photon strength function in molybdenum?

Recent claims of a low-energy enhancement in the photon strength function of {sup 96}Mo are investigated. Using the DANCE detector the gamma-ray spectra following resonance neutron capture was measured. The spectrum fitting method was used to indirectly extract a photon strength function from the gamma-ray spectra. No strong low energy enhancement in the photon strength function was found.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the keV-neutron capture cross section and capture gamma-ray spectrum of isotopes around N=82 region

The keV-neutron capture cross section and capture {gamma}-ray spectra of nuclides with a neutron magic number N= 82, {sup 139}La and {sup 142}Nd, were newly measured by the time-of-flight method. Capture {gamma}-rays were detected with an anti-Compton NaI(T1) spectrometer, and the pulse-height weighting technique was applied to derive the neutron capture cross section. The results were provided with our previous measurements of other nuclides around N= 82, {sup 140}Ce, {sup 141}Pr, {sup 143}Nd and {sup 145}Nd.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of K-capture Probability in the Decay of {sup 139}Ce

We have been studying the KX and gamma rays spectra in the electron capture decay of {sup 139}Ce{yields}{sup 139}La, which were measured by Ge-spectrometer. The absolute intensity of KX and the 165.8 keV gamma rays has been determined and the known conversion coefficients of the 165.8 keV gamma transition of {sup 139}La were used. The probability P{sub K} was determined as 0.755{+-}0.054. Our results have good agreement with the results of other works.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On the non-existence of a sharp cooling break in gamma-ray burst afterglow spectra

Although the widely used analytical afterglow model of gamma-ray bursts (GRBs) predicts a sharp cooling break ν {sub c} in its afterglow spectrum, the GRB observations so far rarely show clear evidence for a cooling break in their spectra or a corresponding temporal break in their light curves. Employing a Lagrangian description of the blast wave, we conduct a sophisticated calculation of the afterglow emission. We precisely follow the cooling history of non-thermal electrons accelerated into each Lagrangian shell. We show that a detailed calculation of afterglow spectra does not in fact give rise to a sharp cooling break at ν {sub c}. Instead, it displays a very mild and smooth transition, which occurs gradually over a few orders of magnitude in energy or frequency. The main source of this slow transition is that different mini shells have different evolutionary histories of the comoving magnetic field strength B, so that deriving the current value of ν {sub c} of each mini shell requires an integration of its cooling rate over the time elapsed since its creation. We present the time evolution of optical and X-ray spectral indices to demonstrate the slow transition of spectral regimes and discuss the implications of our result in interpreting GRB afterglow data.

79 ASTRONOMY AND ASTROPHYSICS↗

Waste Characterization Using Gamma Ray Spectrometry with Automated Efficiency Optimization - 13404

Gamma ray spectrometry using High Purity Germanium (HPGe) detectors is commonly employed in assaying radioactive waste streams from a variety of sources: nuclear power plants, Department of Energy (DOE) laboratories, medical facilities, decontamination and decommissioning activities etc. The radioactive material is typically packaged in boxes or drums (for e.g. B-25 boxes or 208 liter drums) and assayed to identify and quantify radionuclides. Depending on the origin of the waste stream, the radionuclides could be special nuclear materials (SNM), fission products, or activation products. Efficiency calibration of the measurement geometry is a critical step in the achieving accurate quantification of radionuclide content. Due to the large size of the waste items, it is impractical and expensive to manufacture gamma ray standard sources for performing a measurement based calibration. For well over a decade, mathematical efficiency methods such as those in Canberra's In Situ Object Counting System (ISOCS) have been successfully employed in the efficiency calibration of gamma based waste assay systems. In the traditional ISOCS based calibrations, the user provides input data such as the dimensions of the waste item, the average density and fill height of the matrix, and matrix composition. As in measurement based calibrations, the user typically defines a homogeneous matrix with a uniform distribution of radioactivity. Actual waste containers can be quite nonuniform, however. Such simplifying assumptions in the efficiency calibration could lead to a large Total Measurement Uncertainty (TMU), thus limiting the amount of waste that can be disposed of as intermediate or low activity level waste. To improve the accuracy of radionuclide quantification, and reduce the TMU, Canberra has developed the capability to optimize the efficiency calibration using the ISOCS method. The optimization is based on benchmarking the efficiency shape and magnitude to the data available in the analyzed gamma ray spectra. Data from measurements of a given item in multiple counting geometries are among the powerful benchmarks that could be used in the optimization. Also, while assaying a waste stream with fission products and activation products emitting gamma lines of multiple energies, optimizing the efficiency on the basis of line activity consistency is very effective. In the present paper, the ISOCS- based optimization methodology is applied to measurement scenarios involving multiple counting geometries, and multi-gamma-line radionuclides. Results will be presented along with accuracy and precision estimates for each measurement. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhancing GADRAS Source Term Inputs for Creation of Synthetic Spectra

The Gamma Detector Response and Analysis Software (GADRAS) team has enhanced the source term input for the creation of synthetic spectra. These enhancements include the following: allowing users to programmatically provide source information to GADRAS through memory, rather than through a string limited to 256 characters; allowing users to provide their own source decay database information; and updating the default GADRAS decay database to fix errors and include coincident gamma information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative gamma-spectrometry of nuclear material under conditions of limited information about assayed objects

Canberra Industries has developed a specialized software package, Advanced In-Situ Object Counting System (A-ISOCS), which is based on absolute gamma-spectrometric measurements. It is intended for the verification of the quantity of nuclear materials under conditions where measurements are challenged by incomplete information on the properties of assayed objects which are inspected by the International Atomic Energy (IAEA)'s inspectors. A-ISOCS introduces a technique, which is called the automated optimization that allows the users to determine unknown sample parameters as well as the mass and isotopic composition of nuclear materials. The optimization process is carried out by using benchmarks referring the information included within the gamma-ray spectrum of the measured item. For each benchmark, Figure-of-Merit (FOM) is calculated and used to find the most consistent quantitative result (the best solution) corresponded to the minimized FOM. We have evaluated the capabilities and performance of A-ISOCS based on the measurements of uranium standard reference material samples, which have well-known geometry parameters and physical properties. In addition the applicability of the software to field measurements was assessed with an extensive set of gamma-ray spectra from holdup materials collected at uranium bulk handling facilities. This paper summarizes the results of our evaluation activity. (authors)

36 MATERIALS SCIENCE↗

Search for Dark Matter Satellites Using the FERMI-LAT

Numerical simulations based on the {Lambda}CDM model of cosmology predict a large number of as yet unobserved Galactic dark matter satellites. We report the results of a Large Area Telescope (LAT) search for these satellites via the {gamma}-ray emission expected from the annihilation of weakly interacting massive particle (WIMP) dark matter. Some dark matter satellites are expected to have hard {gamma}-ray spectra, finite angular extents, and a lack of counterparts at other wavelengths. We sought to identify LAT sources with these characteristics, focusing on {gamma}-ray spectra consistent with WIMP annihilation through the b{bar b} channel. We found no viable dark matter satellite candidates using one year of data, and we present a framework for interpreting this result in the context of numerical simulations to constrain the velocity-averaged annihilation cross section for a conventional 100 GeV WIMP annihilating through the b{bar b} channel.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A calibration to predict the concentrations of impurities in plutonium oxide by prompt gamma analysis: Revision 1

Over 5,500 containers of excess plutonium-bearing materials have been packaged for long-term storage following the requirements of DOE-STD- 3013. Knowledge of the chemical impurities in the packaged materials is important because certain impurities, such as chloride salts, affect the behavior of the material in storage leading to gas generation and corrosion when sufficient moisture also is present. In most cases, the packaged materials are not well characterized, and information about the chemical impurities is limited to knowledge of the material’s processing history. The alpha-particle activity from the plutonium and americium isotopes provides a method of nondestructive self-interrogation to identify certain light elements through the characteristic, prompt gamma rays that are emitted from alpha-particle-induced reactions with these elements. Gamma-ray spectra are obtained for each 3013 container using a highresolution, coaxial high-purity germanium detector. These gamma-ray spectra are scanned from 800 to 5,000 keV for characteristic, prompt gamma rays from the detectable elements, which include lithium, beryllium, boron, nitrogen, oxygen, fluorine, sodium, magnesium, aluminum, silicon, phosphorus, chlorine, and potassium. The lower limits of detection for these elements in a plutonium-oxide matrix increase with atomic number and range from 100 or 200 ppm for the lightest elements such as lithium and beryllium, to 19,000 ppm for potassium. The peak areas from the characteristic, prompt gamma rays can be used to estimate the concentration of the light-element impurities detected in the material on a semiquantitative basis. The use of prompt gamma analysis to assess impurity concentrations avoids the expense and the risks generally associated with performing chemical analysis on radioactive materials. The analyzed containers are grouped by impurity content, which helps to identify high-risk containers for surveillance and in sorting materials before packaging.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exploring the blazar zone in high-energy flares of FSRQs

The gamma-ray emission offers a powerful diagnostic tool to probe jets and their surroundings in flat-spectrum radio quasars (FSRQs). In particular, sources emitting at high energies (>10 GeV) give us the strongest constraints. This motivates us to start a systematic study of flares with bright emission above 10 GeV, examining archival data of the Fermi-LAT gamma-ray telescope. At the same time, we began to trigger Target of Opportunity observations to the Swift observatory at the occurrence of high-energy flares, obtaining a wide coverage of the spectral energy distributions (SEDs) for several FSRQs during flares. Among others, we investigate the SED of a peculiar flare of 3C 454.3, showing a remarkably hard gamma-ray spectrum, quite different from the brightest flares of this source, and a bright flare of CTA 102. We modeled the SED in the framework of the one-zone leptonic model, using also archival optical spectroscopic data to derive the luminosity of the broad lines and thus estimate the disk luminosity, from which the structural parameters of the FSRQ nucleus can be inferred. The model allowed us to evaluate the magnetic field intensity in the blazar zone and to locate the emitting region of gamma-rays in the particular case in which gamma-ray spectra show neither absorption from the broad-line region (BLR) nor the Klein-Nishina curvature expected in leptonic models assuming the BLR as the source of seed photons for the External Compton scenario. For FSRQs bright above 10 GeV, we were able to identify short periods lasting less than one day characterized by a high rate of high-energy gamma-rays and hard gamma-ray spectra. We discussed the observed spectra and variability timescales in terms of injection and cooling of energetic particles, arguing that these flares could be triggered by magnetic reconnection events or turbulence in the flow.

79 ASTRONOMY AND ASTROPHYSICS↗

MO-AB-BRA-07: Prompt Gamma-Ray Spectroscopy for Range Verification of Clinical Proton Beams

Purpose: We developed a pre-clinical prototype system for range verification of proton pencil-beam scanning fields. The system was evaluated using phantom treatment plans delivered with a clinical dose rate. Methods: The absolute range of proton pencil-beams was verified through an optimization procedure, which matches energy- and time-resolved prompt gamma-ray measurements with models, based on cross sections for discrete prompt gamma-ray line excitations. Phantom experiments were performed with a pre-clinical prototype detector, using treatment plans delivered with a clinical pencil-beam scanning system. The detector consisted of an actively shielded lanthanum(III) bromide scintillator. Tungsten was used to collimate the gamma-rays. To support high event rates, the detector readout featured custom amplifiers and an active voltage divider for the photomultiplier. The detector signals were acquired by fast analog-to-digital converters and processed using digital algorithms. The data acquisition was also synchronized with the pencil-beam scanning and dosimetry systems. Results: We successfully acquired prompt gamma-ray spectra during the delivery of proton pencil-beams with a clinical beam current of 2 nA at the exit of the treatment head. The number of events in the primary detector ranged from 1 x 10{sup 6} to 2 x 10{sup 6} per second. In phantom experiments, non-uniform range errors were introduced by placing strips of plastic in the beam path. The magnitudes and positions of these range errors were correctly detected in two-dimensional range maps that were generated from the measurements. With our small scale prototype, a 1.0 mm standard deviation on the absolute range required about 5 x 10{sup 8} protons per delivered pencil-beam. Conclusions: Prompt gamma-ray spectroscopy to verify the absolute range of proton beams was demonstrated under clinical pencil-beam delivery conditions. A 1 mm to 2 mm range verification accuracy for a field delivering 1 Gy, appears feasible with a full scale system. This work was supported by the Federal Share of program income earned on C06-CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗

Automated isotope identification algorithm using artificial neural networks

There is a need to develop an algorithm that can determine the relative activities of radio-isotopes in a large dataset of low-resolution gamma-ray spectra that contains a mixture of many radio-isotopes. Low-resolution gamma-ray spectra that contain mixtures of radio-isotopes often exhibit feature over-lap, requiring algorithms that can analyze these features when overlap occurs. While machine learning and pattern recognition algorithms have shown promise for the problem of radio-isotope identification, their ability to identify and quantify mixtures of radio-isotopes has not been studied. Because machine learning algorithms use abstract features of the spectrum, such as the shape of overlapping peaks and Compton continuum, they are a natural choice for analyzing radio-isotope mixtures. An artificial neural network (ANN) has be trained to calculate the relative activities of 32 radio-isotopes in a spectrum. Furthermore, the ANN is trained with simulated gamma-ray spectra, allowing easy expansion of the library of target radio-isotopes. In this paper we present our initial algorithms based on an ANN and evaluate them against a series measured and simulated spectra.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IDENTIFYING BREAKS AND CURVATURE IN THE FERMI SPECTRA OF BRIGHT FLAT SPECTRUM RADIO QUASARS

Knowing the site of {gamma}-ray emission in active galactic nucleus jets will do much for our understanding of the physics of the source. In particular, if the emission region is close to the black hole then absorption of {gamma}-rays with photons from the broad-line region could become significant. Such absorption is predicted to produce two specific spectral breaks in the {gamma}-ray spectra of Flat Spectrum Radio Quasars (FSRQs). We test this hypothesis using three years of Fermi observations of nine bright FSRQs. A simple power-law fit to the spectrum of each source can be significantly improved by introducing a break, but the break energies are inconsistent with those predicted by the double-absorber model. In some cases the fit can be further improved by a log-parabola. In addition, by dividing the data from each source into two equal epochs we find that the best description of an object's spectrum often varies between a log-parabola and a broken power law.

79 ASTRONOMY AND ASTROPHYSICS↗