Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Underwater characterization of control rods for waste disposal using SMOPY

Storage of spent fuel assemblies in cooling ponds requires careful control of the geometry and proximity of adjacent assemblies. Measurement of the fuel burnup makes it possible to optimise the storage arrangement of assemblies taking into account the effect of the burnup on the criticality safety margins ('burnup credit'). Canberra has developed a measurement system for underwater measurement of spent fuel assemblies. This system, known as 'SMOPY', performs burnup measurements based on gamma spectroscopy (collimated CZT detector) and neutron counting (fission chamber). The SMOPY system offers a robust and waterproof detection system as well as the needed capability of performing radiometric measurements in the harsh high dose - rate environments of the cooling ponds. The gamma spectroscopy functionality allows powerful characterization measurements to be performed, in addition to burnup measurement. Canberra has recently performed waste characterisation measurements at a Nuclear Power Plant. Waste activity assessment is important to control costs and risks of shipment and storage, to ensure that the activity level remains in the range allowed by the facility, and to declare activity data to authorities. This paper describes the methodology used for the SMOPY measurements and some preliminary results of a radiological characterisation of AIC control rods. After describing the features and normal operation of the SMOPY system, we describe the approach used for establishing an optimum control rod geometric scanning approach (optimum count time and speed) and the method of the gamma spectrometry measurements as well as neutron check measurements used to verify the absence of neutron sources in the waste. We discuss the results obtained including {sup 60}Co, {sup 110m}Ag and {sup 108m}Ag activity profiles (along the length of the control rods) and neutron results including Total Measurement Uncertainty evaluations. Full self-consistency checks were performed and these demonstrate the validity of the techniques. The results are described and analysed in the context of the measurement performance of the equipment. Different casks were fully characterized using a 60 mm{sup 3} CZT detector, to determine the total activities and spatial profiles. A total activity range measurement of 1x10{sup 8} - 1x10{sup 13} Bq/cm was found to be achievable. Finally, comments are made, based on our measurements, on the ability of this equipment for performing in-situ characterisation of wastes in the harsh environments typical of fuel assembly and waste storage ponds and silos. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hard X-ray spectrum of Cygnus X-1

Long-term measurements of the hard X-ray spectrum from 3 keV to 8 MeV of the black-hole candidate Cygnus X-1 in its low state are reported. Observations were made from October 26 to November 18, 1977 with the A2 (Cosmic X-ray) and A4 (Hard X-ray and Low-Energy Gamma-Ray) experiments on board HEAO 1 in the spacecraft's scanning mode. The measured spectrum below 200 keV is found to agree well with previous spectra which have been fit by a model of the Compton scattering of optical or UV photons in a very hot plasma of electron temperature 32.4 keV and optical depth 3.9 or 1.6 for spherical or disk geometry, respectively. At energies above 300 keV, however, flux excess is observed which may be accounted for by a distribution of electron temperatures from 15 to about 100 keV.

Nolan, P. L.↗

Rotating-unbalanced-mass Devices for Scanning Balloon-borne Experiments, Free-flying Spacecraft, and Space Shuttle/space Station Experiments

A new method is presented for scanning balloon-borne experiments, free-flying spacecraft, and gimballed experiments mounted to the space shuttle or the space station. It uses rotating-unbalanced-mass (RUM) devices for generating circular, line, or raster scan patterns and an auxiliary control system for target acquisition, keeping the scan centered on the target, and producing complementary motion for raster scanning. It is ideal for applications where the only possible way to accomplish the required scan is to physically scan the entire experiment or spacecraft as in x ray and gamma ray experiments. In such cases, this new method should have advantages over prior methods in terms of either power, weight, cost, performance, stability, or a combination of these.

Polites, Michael E.↗

SU-E-T-205: Improving Quality Assurance of HDR Brachytherapy: Verifying Agreement Between Planned and Delivered Dose Distributions Using DICOM RTDose and Advanced Film Dosimetry

Purpose: HDR brachytherapy is undergoing significant development, and quality assurance (QA) checks must keep pace. Current recommendations do not adequately verify delivered against planned dose distributions: This is particularly relevant for new treatment planning system (TPS) calculation algorithms (non TG-43 based), and an era of significant patient-specific plan optimisation. Full system checks are desirable in modern QA recommendations, complementary to device-centric individual tests. We present a QA system incorporating TPS calculation, dose distribution export, HDR unit performance, and dose distribution measurement. Such an approach, more common in external beam radiotherapy, has not previously been reported in the literature for brachytherapy. Methods: Our QA method was tested at 24 UK brachytherapy centres. As a novel approach, we used the TPS DICOM RTDose file export to compare planned dose distribution with that measured using Gafchromic EBT3 films placed around clinical brachytherapy treatment applicators. Gamma analysis was used to compare the dose distributions. Dose difference and distance to agreement were determined at prescription Point A. Accurate film dosimetry was achieved using a glass compression plate at scanning to ensure physically-flat films, simultaneous scanning of known dose films with measurement films, and triple-channel dosimetric analysis. Results: The mean gamma pass rate of RTDose compared to film-measured dose distributions was 98.1% at 3%(local), 2 mm criteria. The mean dose difference, measured to planned, at Point A was -0.5% for plastic treatment applicators and -2.4% for metal applicators, due to shielding not accounted for in TPS. The mean distance to agreement was 0.6 mm. Conclusion: It is recommended to develop brachytherapy QA to include full-system verification of agreement between planned and delivered dose distributions. This is a novel approach for HDR brachytherapy QA. A methodology using advanced film dosimetry and gamma comparison to DICOM RTDose files has been demonstrated as suitable to fulfil this need.

07 ISOTOPE AND RADIATION SOURCES↗

A comparison of collimator geometries for imaging mixed radiation fields with fast liquid organic scintillators

As a result of recent advances in digital pulse-shape discrimination methods it has become possible to image mixed fields (radiation environments compromising both neutrons and gamma rays) relatively quickly with a single, organic liquid 'fast' scintillator within a heavy metal collimator. The use of a liquid scintillator has significant benefits over other techniques for imaging radiation environments as the acquired data can be analysed to provide separate information about the gamma and neutron emissions from a source (or sources) in a single scan. The imaging resolution achieved is fundamentally related to the detector efficiency and to the collimator geometry. In this paper the impact of using two different geometries of tungsten collimator are compared experimentally and three different materials considered in the Monte Carlo simulation, in order to determine the optimum set-up for mixed-field imaging. The measurements were performed in the low-scatter facility of the National Physical Laboratory, Teddington. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-154: An Evaluation and Quantification of Secondary Neutron Radiation Dose Due to Double Scatter and Pencil Beam Scanning Proton Therapy

Proton radiation therapy can deliver high radiation doses to tumors while sparing normal tissue. However, protons yield secondary neutron and gamma radiation that is difficult to detect, small in comparison to the prescribed dose, and not accounted for in most treatment planning systems. The risk for secondary malignancies after proton therapy may be dependent on the quality of this dose. Consequently, there is interest in characterizing the secondary radiation. Previously, we used the dual ionization chamber method to measure the separate absorbed dose from gamma-rays and neutrons secondary to the proton beam1, relying on characterization of ionization chamber response in the unknown neutron spectrum from Monte Carlo simulation. We developed a procedure to use Shieldwerx activation foils, with neutron activation energies ranging from 0.025 eV to 13.5 MeV, to measure the neutron energy spectrum from double scattering (DS) and pencil beam scanning (PBS) protons outside of the treatment volume in a water tank. The activated foils are transferred to a NaI well chamber for gamma-ray spectroscopy and activity measurement. Since PBS treats in layers, the switching time between layers is used to correct for the decay of the activated foils and the relative dose per layer is assumed to be proportional to the neutron fluence per layer. MATLAB code was developed to incorporate the layer delivery and switching time into a calculation of foil activity, which is then used to determine the neutron energy fluence from tabulated foil activation energy thresholds.1. Diffenderfer et. al., Med. Phys., 38(11) 2011.

60 APPLIED LIFE SCIENCES↗

Interaction of hydrogen chloride with alumina

The influence of temperature, pressure, and outgas conditions on the absorption of hydrogen chloride and water vapor on both alpha and gamma alumina was studied. Characterization of the adsorbents was performed using X-ray powder diffraction, scanning electron microscopy (SEM), low temperature nitrogen adsorption desorption measurements, BET nitrogen surface area measurements and electron spectroscopy for chemical analysis (ESCA). Water vapor adsorption isotherms at 30, 40, and 50 C were measured on alpha and gamma alumina after outgassing at 80, 200, and 400 C. Both outgas temperature and adsorption temperature influenced the adsorption of water vapor on the aluminas. The water vapor adsorption was completely reversible. Alpha alumina absorbed more water per unit area than gamma alumina. Differences in the adsorption capacity for water vapor of the two aluminas were explained on the basis of ideal surface models of alpha and gamma alumina. Isosteric heats of adsorption for water vapor on the aluminas were determined over a limited range of surface coverage.

Bailey, R. R.↗

Dosimetric property of mineral extracted from calamari and exposed to gamma rays

Dosimetric property of polymineral fraction, quartz mainly, obtained from calamari was investigated. The commercial calamari samples from China and Sud Africa were collected in the markets of Italy. All polymineral debris were extracted and isolated from the whole body of calamari. The surface of the polymineral samples was analyzed by using the Scanning Electron Microscopy (SEM) and their chemical composition was determined using Energy Dispersive Spectroscopy (EDS). The polymineral was exposed to gamma rays ({sup 60}Co) at different doses (0.5-80 Gy) to determine dosimetric property. Thermoluminescent (TL) glow curves showed two peaks centered at around 98-100 Degree-Sign C and 128-138 Degree-Sign C temperature range. The glow curves have been analyzed by using a deconvolution program. A linear dose response between 0.5 to 20 Gy was observed. The TL response of the samples as a function of the time storage, fading, presented a reduction of about 36-40 % at the end of 24 h. The reproducibility of the TL response after ten cycles of irradiation-readout showed an acceptable standard deviation in dosimetry. The polimineral fraction obtained from calamari shows an interesting dosimetric property and it may be useful for dosimetry in gamma radiation field.

36 MATERIALS SCIENCE↗

Pointing and Scanning Control of Optical Instruments using Rotating Unbalanced Masses

Correct pointing direction and scanning motions are essential in the operation of many flight payloads, such as balloon-borne telescopes and space-based X- ray and gamma-ray telescopes. Rotating unbalanced mass (RUM) devices have been recently proposed, implemented and successfully tested to produce a variety of scanning motions. Linear scans, raster scans, and circular scans have been successfully generated on a gimbaled payload using pairs of RUM devices. Theoretical analysis, computer simulations, and experiments have also been used to study the feasibility of using RUM devices to control instrument pointing direction, in addition to generating scanning motion. Dynamic modeling of a gimbaled payload equipped with a pair of RUM devices has been studied, and preliminary testing indicates that the pointing control is indeed feasible. However, there is also great potential for significant performance improvements through more advanced control system analysis, modeling and design. In this paper, modeling and control methods are described to achieve simultaneous scanning and pointing control of a gimbaled payload using rotating unbalance mass (RUM) devices. The model development work builds upon the results of Polites et al. and also some modeling approaches from robotics research. Results of some preliminary experiments are discussed and some nonlinear control methods will be proposed.

Bishop, Carlee A.↗

Gamma-Ray Signatures for State-Of-Health Analysis and Monitoring of Widely-Arrayed Radiation Portal Monitor Systems

Pacific Northwest National Laboratory (PNNL) has deployed a large array of radiation portal monitors for the Department of Homeland Security U.S. Customs and Border Protection. These portal monitors scan incoming vehicles crossing the U.S. border and shipping containers leaving international ports for radioactive material via gamma-ray and neutron detection. Data produced and captured by these systems are recorded for every vehicle related to radiation signature, sensor/system status, and local background, as well as a host of other variables. Within the Radiation Portal Monitor Project at PNNL, state-of-health observation and analysis for the whole RPM system using these data to determine functionality and performance is being developed. (PIET-43741-TM-492)

Woodring, Mitchell L↗

Scanning with charge-coupled devices

Results are presented of an investigation of six modes of using CCDs for searches of gamma-ray bursters, debris in geosynchronous space, satellites of asteroids, brown dwarfs, the tenth planet, comets, cometesimals, and various types of asteroids. A new discipline in astrophysics, 'scannerscopy', i.e., surveying with a CCD rather than with photography at a Schmidt telescope, is described. It uses the CCD in scanning rather than in sequencing of stare exposures as is done at most observatories, which can save telescope time and obviates the need for flat-fielding. Attention is given to the Tektronix 2048 x 2048 CCD, 38 arcmin wide, which is used to a limiting magnitude of 20.5 V. It is also shown to be successful for discovering rare and small near-earth asteroids. Possibilities with cameras on spacecraft that pass through the asteroid belt are described.

Gehrels, Tom↗

SISGR: Linking Ion Solvation and Lithium Battery Electrolyte Properties

The solvation and phase behavior of the model battery electrolyte salt lithium trifluoromethanesulfonate (LiCF 3 SO 3 ) in commonly used organic solvents; ethylene carbonate (EC), gamma-butyrolactone (GBL), and propylene carbonate (PC) was explored. Data from differential scanning calorimetry (DSC), Raman spectroscopy, and X-ray diffraction were correlated to provide insight into the solvation states present within a sample mixture. Data from DSC analyses allowed the construction of phase diagrams for each solvent system. Raman spectroscopy enabled the determination of specific solvation states present within a solvent-salt mixture, and X-ray diffraction data provided exact information concerning the structure of a solvates that could be isolated Thermal analysis of the various solvent-salt mixtures revealed the phase behavior of the model electrolytes was strongly dependent on solvent symmetry. The point groups of the solvents were (in order from high to low symmetry): C2V for EC, CS for GBL, and C1 for PC(R). The low symmetry solvents exhibited a crystallinity gap that increased as solvent symmetry decreased; no gap was observed for EC-LiTf, while a crystallinity gap was observed spanning 0.15 to 0.3 mole fraction for GBL-LiTf, and 0.1 to 0.33 mole fraction for PC(R)-LiTf mixtures. Raman analysis demonstrated the dominance of aggregated species in almost all solvent compositions. The AGG and CIP solvates represent the majority of the species in solutions for the more concentrated mixtures, and only in very dilute compositions does the SSIP solvate exist in significant amounts. Thus, the poor charge transport characteristics of CIP and AGG account for the low conductivity and transport properties of LiTf and explain why is a poor choice as a source of Li + ions in a Li-ion battery.

25 ENERGY STORAGE↗

Chemiluminescence of nitric oxide

Measurements of the intensities of the delta and gamma bands of nitric oxide in the nighttime terrestrial thermosphere are presented and used to infer the rate coefficient for the transition from the C 2 Pi to the A 2 Sigma + states. The nightglow spectrum was observed between 1900 and 2300 A at a resolution of 15 A by a rocket-borne scanning 1/4-m spectrometer pointing north at an apogee of 150 km. Progressions of the delta, gamma and epsilon bands are identified on the spectra by the construction of synthetic spectra, and the contributions of resonance fluorescence to the total band intensities are calculated. Finally, the ratio of the sum of the gamma bands for v-prime = 0 to the sum of the delta bands for v-prime = 0 is used to derive a branching ratio of 0.21 + or - 0.04 to the A 2 Sigma + state, which yields a probability for the C-A transition of 5.6 + or - 1.5 x to the 6th/sec.

Sharp, W. E.↗

Test of 3D CT reconstructions by EM + TV algorithm from undersampled data

Computerized tomography (CT) plays an important role in medical imaging for diagnosis and therapy. However, CT imaging is connected with ionization radiation exposure of patients. Therefore, the dose reduction is an essential issue in CT. In 2011, the Expectation Maximization and Total Variation Based Model for CT Reconstruction (EM+TV) was proposed. This method can reconstruct a better image using less CT projections in comparison with the usual filtered back projection (FBP) technique. Thus, it could significantly reduce the overall dose of radiation in CT. This work reports the results of an independent numerical simulation for cone beam CT geometry with alternative virtual phantoms. As in the original report, the 3D CT images of 128 Multiplication-Sign 128 Multiplication-Sign 128 virtual phantoms were reconstructed. It was not possible to implement phantoms with lager dimensions because of the slowness of code execution even by the CORE i7 CPU.

61 RADIATION PROTECTION AND DOSIMETRY↗

The effects of electron and gamma radiation on epoxy-based materials

Specimens of graphite/epoxy composites and epoxy resins were exposed to electron and gamma radiation, followed by mechanical property and fundamental measurements. Measurement techniques included: scanning electron microscopy, X-ray diffraction analysis, and electron spin resonance spectroscopic analysis. Results indicate little or no change in flexural properties of miniature specimens of a graphite/epoxy composite and no change in failure mode at the fiber-resin interface and in the crystallinity of the fiber and the resin. Some doubt in the observation of stable flexural properties is cast by electron paramagnetic resonance spectra of a relatively large number of radiation-generated radicals. These generally lead to a change in cross-linking and in chain-scissioning which should alter mechanical properties.

Fornes, R. E.↗

Nonthermal synchrotron radiation in a strong magnetic field

A synchrotron source model is presented for the origin of gamma-ray bursts from neutron stars. The field strength and length of time needed for electrons to lose sufficient energy in emitting the gamma rays are calculated, together with the efficiency of the process, limiting frequencies, and the energy output. A Monte Carlo simulation of the synchrotron radiation spectrum of an electron undergoing a self-consistent energy loss demonstrates that a process involving thermalized electrons can be sufficiently efficient to produce 30 keV gamma rays. Problems expected in using the current capabilities of detectors to scan for the projected energy spectra from fields of at least 3 x 10 to the 12th Gauss are discussed.

Bussard, R. W.↗

New method for scanning spacecraft and balloon-borne/space-based experiments

A new method is presented for scanning balloon-borne experiments, free-flying spacecraft, and gimballed experiments mounted to the space shuttle or the space station. It uses rotating-unbalanced-mass (RUM) devices for generating circular, line, or raster scan patterns and an auxiliary control system for target acquisition, keeping the scan centered on the target, and producing complementary motion for raster scanning. It is ideal for applications where the only possible way to accomplish the required scan is to physically scan the entire experiment or spacecraft as in X-ray and gamma ray experiments. In such cases, this new method should have advantages over prior methods in terms of either power, weight, cost, performance, stability, or a combination of these.

Polites, Michael E.↗

Tracking radioactivity content in the spent fuel pool in PWRS - 15150

Over the last decade, significant progress has been made in managing radioisotopes generated in the PWR primary systems. These include limiting the use of cobalt containing materials, along with improved fuel performance and zinc injection to passivate the corrosion layers to limit the accumulation of Co-58 and Co-60 on primary coolant surfaces. Attention here is directed to the spent fuel pool where accumulation of spent fuel and activated material represents a growing source of mobile radioactivity supplemented with periodic exchanges of water from the reactor cooling system. Characterization of this source is increasingly important to effective management of disposal options. This paper examines the radioactive resin source term as determined from routine sampling of the coolant and fuel pool liquids. Targeted resin stream sampling and radiochemical analyses conducted at Diablo Canyon serve to inform and provide context for this examination. This examination is supplemented with computer modelling using the DW James Consulting computer program, 3R-SCAN. At most operating plants daily reactor coolant samples are counted using gamma spectroscopy and recorded. These samples serve to track fuel performance and maintain water chemistry. A secondary use for this data is to maintain a day to day tracking of releases of radioisotopes important to waste disposal. Given the coolant concentrations, plant operating history, and corroborative mathematical models and sampling, accumulation of these radioisotopes in coolant cleanup system ion-exchangers can be predicted. Fuel pool sampling is less frequent, but at the same time, things change more slowly there. The fuel pool contains about ten times the volume of the reactor coolant but its cleanup system process rate is comparable to reactor coolant letdown, i.e. 5.047 - 8.833 liters per second [lps] (80-140 gallons per minute [gpm]). A spent fuel pool clean-up demineralizer flow rate is typically about 5.047 lps (80 gpm). Concentrations of longer lived radioisotopes in the spent fuel pool can be comparable to those in reactor coolant. Releases of corrosion products and fission products from the stored fuel occur at a low rate but given the overall inventory can be significant. Recognized scaling factor ratios, particularly those to Co-60, are skewed by the aging of the material in the pool. An additional consideration stems from refueling operations themselves. Prior to refueling, it is common practice to conduct a forced oxidation of the corrosion films within the reactor. This spikes the activity within the reactor coolant. Most of this activity is removed by the reactor coolant purification system prior to removing the reactor head. This paper examines the accumulation of activity in the fuel pool purification ion exchange resins and how it impacts the overall classification of those ion exchange resins. The following discussion focuses on the transport of nickel and cobalt isotopes particularly as it relates to determination of Ni-63 which has become increasingly prominent in disposal classification. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗