Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Simulation of Isotopic Concentrations and Gamma Spectra from Dynamic Fission Sources

A tool was developed to rapidly generate synthetic gamma-ray spectra to evaluate safeguards material control and accounting methods for liquid-fueled molten salt reactors. Molten salt reactor operations pose unique challenges to nuclear safeguards methods and protocols compared to deployed reactors designs (e.g., light water reactors). This research evaluates the use of gamma-ray spectroscopy to monitor fission product isotopic flow through a reactor model to understand expected operations and investigate changes to the spectra with material diversion scenarios. The large design space of molten salt reactors (e.g., liquid-fueled, liquid-cooled, online separations) could potentially lead to many measurement points within the reactor system. The developed analytical tool generates and evaluates synthetic gamma-ray spectra from dynamic reactor simulations by extracting isotopic inventory to generate source terms. An implementation in the Gamma Detector Response and Analysis Software (GADRAS) Application Program Interface (API) uses the source terms, a model of the reactor component, a detector response function, and measurement plan to quickly generate and analyze spectra. Prospective measurements are then evaluated in the more accurate but slower Geant4 simulations. Utilization of the developed modeling tool and analysis of the subsequent spectra enables optimization of collimation, shielding requirements, and expected count rates that are used to determine key measurement points in the modeled reactor design.

O'Brien, Sean↗

Gamma-Ray Pulse Tube Cooler Development and Testing

For a variety of space-science applications, such as gamma-ray spectroscopy, the introduction of cryogenic cooling via a cryocooler can greatly increase the potential science return by allowing the use of more sensitive and lower noise detectors.

gamma-ray cryogenic cryocooler pulse tube↗

Preliminary design and performance of an advanced gamma ray spectrometer for future orbiter missions

A knowledge of the composition of planets, satellites, and asteroids is of primary importance in understanding the formation and evolution of the solar system. Gamma-ray spectroscopy is capable of measuring the composition of meter-depth surface material from orbit around any body possessing little or no atmosphere. Measurement sensitivity is determined by detector efficiency and resolution, counting time, and the background flux while the effective spatial resolution depends upon the field-of-view and counting time together with the regional contrast in composition. The advantages of using germanium as a detector of gamma rays in space are illustrated experimentally and a compact instrument cooled by passive thermal radiation is described. Calculations of the expected sensitivity of this instrument at the Moon and Mars show that at least a dozen elements will be detected, twice the number which have been isolated in the Apollo gamma-ray data.

Metzger, A. E.↗

Preliminary design and performance of an advanced gamma-ray spectrometer for future orbiter missions

A knowledge of the composition of planets, satellites, and asteroids is of primary importance in understanding the formation and evolution of the solar system. Gamma-ray spectroscopy is capable of measuring the composition of meter-depth surface material from orbit around any body possessing little or no atmosphere. Measurement sensitivity is determined by detector efficiency and resolution, counting time and the background flux, while the effective spatial resolution depends upon the field-of-view and counting time together with the regional contrast in composition. The advantages of using germanium as a detector of gamma rays in space are illustrated experimentally and a compact instrument cooled by passive thermal radiation is described. Calculations of the expected sensitivity of this instrument at the moon and Mars show that at least a dozen elements should be measurable, twice the number which have been isolated in the Apollo gamma-ray data

Metzger, A. E.↗

SONGS - A high resolution imaging gamma-ray spectrometer for the Space Station

The overall design and the instrumental features of the Space-Station Observer for Nuclear Gamma-ray Spectroscopy (SONGS) instrument are described. SONGS comprises an array of 19 two-segment n-type Ge detectors, which have the capability of determining the interaction site in either the upper or the lower segment or in both segments. The detectors provide high energy resolution of 1 keV at 100 keV and of 2 keV at 1 MeV. The close-packed Ge sensor array provides a natural sensitivity for the measurement of gamma ray polarization in the 100 keV to 1 MeV energy range, making it possible to obtain information on the structure of the magnetosphere of neutron stars and of the accretion disk of black holes.

Nakano, G. H.↗

Hard X-ray and low-energy gamma-ray spectrometers

Basic principles of operation and characteristics of scintillation and semi-conductor detectors used for solar hard X-ray and gamma-ray spectrometers are presented. Scintillation materials such as NaI offer high stopping power for incident gamma rays, modest energy resolution, and relatively simple operation. They are, to date, the most often used detector in solar gamma-ray spectroscopy. The scintillator BGO has higher stopping power than NaI, but poorer energy resolution. The primary advantage of semi-conductor materials such as Ge is their high-energy resolution. Monte-Carlo simulations of the response of NaI and Ge detectors to model solar flare inputs show the benefit of high resoluton for studying spectral lines. No semi-conductor material besides Ge is currently available with adequate combined size and purity to make general-use hard X-ray and gamma-ray detectors for solar studies.

Gehrels, N.↗

A position-sensitive germanium detector for gamma-ray astronomy

The critical problem in high-resolution cosmic gamma-ray spectroscopy in the energy range from 0.02 to 10 MeV is the limited spectral sensitivity of the detectors used. This results from the small effective area of the detectors and the high background noise due to induced radioactivity and scattering in the detectors' high-energy particle environment. The effective area can be increased by increasing the number of detectors, but this becomes prohibitive because of the size and expense of the resulting instrument. We have taken a new approach: a segmented large-volume germanium gamma-ray detector which can effectively discriminate against internal background yet maintain the high spectral resolution and efficiency of conventional coaxial Ge detectors. To verify this concept, a planar detector divided into two segments has been fabricated and laboratory measurements agree well with Monte Carlo calculations. A large coaxial detector which will be divided into five segments is being built using the techniques developed for the planar detector. Monte Carlo calculations show that the sensitivity (minimum detectable flux) of the segmented coaxial detector is a factor of 2-3 better than conventional detectors because of the reduction in the internal background.

Varnell, L. S.↗

Time-resolved Neutron-gamma-ray Data Acquisition for in Situ Subsurface Planetary Geochemistry

The current gamma-ray/neutron instrumentation development effort at NASA Goddard Space Flight Center aims to extend the use of active pulsed neutron interrogation techniques to probe the subsurface elemental composition of planetary bodies in situ. Previous NASA planetary science missions, that used neutron and/or gamma-ray spectroscopy instruments, have relied on neutrons produced from galactic cosmic rays. One of the distinguishing features of this effort is the inclusion of a high intensity 14.1 MeV pulsed neutron generator synchronized with a custom data acquisition system to time each event relative to the pulse. With usually only one opportunity to collect data, it is difficult to set a priori time-gating windows to obtain the best possible results. Acquiring time-tagged, event-by-event data from nuclear induced reactions provides raw data sets containing channel/energy, and event time for each gamma ray or neutron detected. The resulting data set can be plotted as a function of time or energy using optimized analysis windows after the data are acquired. Time windows can now be chosen to produce energy spectra that yield the most statistically significant and accurate elemental composition results that can be derived from the complete data set. The advantages of post-processing gamma-ray time-tagged event-by-event data in experimental tests using our prototype instrument will be demonstrated.

Pulsed neutrongenerator↗

Time-Resolved Data Acquisition for In Situ Subsurface Planetary Geochemistry

The current gamma-ray/neutron instrumentation development effort at NASA Goddard Space Flight Center aims to extend the use of active pulsed neutron interrogation techniques to probe the subsurface geochemistry of planetary bodies in situ. All previous NASA planetary science missions, that used neutron and/or gamma-ray spectroscopy instruments, have relied on a constant neutron source produced from galactic cosmic rays. One of the distinguishing features of this effort is the inclusion of a high intensity 14.1 MeV pulsed neutron generator synchronized with a custom data acquisition system to time each event relative to the pulse. With usually only one opportunity to collect data, it is difficult to set a priori time-gating windows to obtain the best possible results. Acquiring time-tagged, event-by-event data from nuclear induced reactions provides raw data sets containing channel/energy, and event time for each gamma ray or neutron detected. The resulting data set can be plotted as a function of time or energy using optimized analysis windows after the data are acquired. Time windows can now be chosen to produce energy spectra that yield the most statistically significant and accurate elemental composition results that can be derived from the complete data set. The advantages of post-processing gamma-ray time-tagged event-by-event data in experimental tests using our prototype instrument will be demonstrated.

Bodnarik, Julia Gates↗

Melt Blending: A Tool to Simplify Plastic Scintillator Synthesis

Plastic scintillators are widely used as radiation detection media in homeland security and nuclear physics applications. Their attributes include low cost, scalability to large detector volumes, and additive compounding to enable additional material and detection features, such as pulse shape discrimination (PSD), gamma-ray spectroscopy, aging resistance, and coincidence timing. However, traditional chemically cured plastic scintillators (CCS) require long reaction times, and hazardous wet chemical procedures performed by specially trained personnel, and can leave residual monomer, resulting in deleterious optical and material properties. Here, we synthesize melt blended scintillators (MBSs) in 2.5 days using easily accessible solid-state compounding of commercially-available poly(styrene) with 30–60 wt% fluorene-based compound “P2” to create monolithic detectors with < 100 ppm residual monomer, in several form factors. Further, the best scintillation performance was recorded for 60 wt% P2 in Styron 665, including gamma-ray light yield 139% of EJ- 200 commercial scintillator and PSD figure of merit (FOM) value of 2.65 at 478 keVee, approaching P2 organic glass scintillator (OGS). The capability of MBS to generate fog-resistant scintillators and poly(methyl methacrylate) (PMMA)-based scintillators for use in challenging environments is also demonstrated.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

HEAO 3 observations of strong variable 0.5-3 MeV emission from the Taurus region

Preliminary results are reported of observations of strong (greater than 10 sigma) variable MeV emission from the Taurus region, possibly the Crab nebula, in 1980 by the HEAO 3 Gamma-Ray Spectroscopy experiment. The about 50-day time-averaged spectrum of the Crab shows a new component, which consists of a hard spectral 'knee' in the 0.4-1 MeV range, followed by a higher energy component extending to greater than 3 MeV, superposed on the canonical Crab power law spectrum with a spectral index of 2.2. This new spectral component was not observed four months earlier in the fall of 1979, when the spectrum was consistent with a single power law with the index of 2.2, the same as that observed in 1980. There is no indication that the gamma-ray emission was pulsed.

Ling, James C.↗

Explaining machine-learning models for gamma-ray detection and identification

As more complex predictive models are used for gamma-ray spectral analysis, methods are needed to probe and understand their predictions and behavior. Recent work has begun to bring the latest techniques from the field of Explainable Artificial Intelligence (XAI) into the applications of gamma-ray spectroscopy, including the introduction of gradient-based methods like saliency mapping and Gradient-weighted Class Activation Mapping (Grad-CAM), and black box methods like Local Interpretable Model-agnostic Explanations (LIME) and SHapley Additive exPlanations (SHAP). In addition, new sources of synthetic radiological data are becoming available, and these new data sets present opportunities to train models using more data than ever before. In this work, we use a neural network model trained on synthetic NaI(Tl) urban search data to compare some of these explanation methods and identify modifications that need to be applied to adapt the methods to gamma-ray spectral data. We find that the black box methods LIME and SHAP are especially accurate in their results, and recommend SHAP since it requires little hyperparameter tuning. We also propose and demonstrate a technique for generating counterfactual explanations using orthogonal projections of LIME and SHAP explanations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On the Mechanism of the Steady-State Gamma Radiolysis-Induced Scissions of the Phenyl-Vinyl Polyester-Based Resins

The major societal problem of polymeric waste necessitates new approaches to break down especially challenging discarded waste streams. Gamma radiation was utilized in conjunction with varying solvent environments in an attempt to discern the efficacy of radiolysis as a tool for the deliberate degradation of model network polyesters. Our EPR results demonstrated that gamma radiolysis of neat resin and in the presence of four widely used solvents induces glycosidic scissions on the backbone of the polyester chains. EPR results clearly show the formation of alkoxy radicals and C-centered radicals as primary intermediate radiolytic products. Despite the protective role of the phenyl groups on the backbone of the radiation-induced polyester chains, the radiolytic-glycosidic scissions predominate. Among the following three solvents used in this study (water, isopropyl alcohol, and dichloromethane), the highest radiolytic yield of glycosidic scission was achieved using water. The •OH radicals produced in the radiolysis of phenyl unsaturated polyester aqueous suspensions very rapidly abstract H atoms from the methylene group, which is followed by a very rapid glycosidic scission. The lowest glycosidic yield was found in the dichloromethane solutions of these polyester resins due to scavenging by the fast electron capture reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Field Scoping Study of Gamma-Ray Measurement of UF 6 Cristillini Samples with CZT and HPGe Detectors

A field scoping study was conducted to evaluate the ability of Cd-Zn-Te (CZT) detectors and High Purity Germanium (HPGe) detectors to quantify the U-235 enrichment in UF 6 samples collected on alumina in P-10 tubes, similar to the Cristillini method of sample collection for analysis by mass spectrometry. With in-field gamma-ray spectroscopy methods, international safeguards and verification missions could benefit from quick in-field confirmation of declared enrichment values prior to or without the need for additional shipping, sample preparation and analysis. Samples of depleted (DU), low-enriched (LEU) and high-assay low-enriched (HALEU) uranium were collected on Cristillini-type alumina in P-10 tubes and measured with two H3D, Inc. M400 CZT detectors as well as a Canberra Falcon HPGe detector. The M400 detectors were able to confirm enrichment in the DU and LEU samples but not the HALEU sample in measurements 8-40 hrs after collection. The Falcon system was able to confirm enrichment in all three samples. Improvements in detector geometry, increase in number of detectors as well as increase sample mass loading may allow measurement of U-235 enrichment in these types of samples within 4-8hrs of collection with 5-10% uncertainty.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Characterization of a platform for the gas transport, collection, and identification of fission products in the high-intensity laser environment

Recent progress in the production of laser accelerated high flux proton beams opens new possibilities for the study of fission in unique environments. To this end, we are currently pursuing the development of a platform for the swift gas transport, collection, and identification of fission products. Fission is induced in targets fixed inside a sealed chamber through which a carrier gas flows, transporting fission products to a carbon filter for collection and online spectroscopy. This has been recently demonstrated using target normal sheath accelerated protons at the PHELIX laser facility. There were large discrepancies between measured rates and those expected based on established fission yields and measured beam parameters. These discrepancies prompted a large number of tests at the Idaho Accelerator Center (IAC), where fission in uranium is induced by bremsstrahlung photons generated by 21 MeV electrons from a linear electron accelerator. Here, the results are compared to a series of models that account for the slowing of energetic fission fragments in the carrier gas and the fluid dynamics of the gas flow that transports fission products to the collection filter. Characterization of the apparatus reveals a few mechanisms that together account for a portion of the previously observed discrepancies at the PHELIX laser facility. However, additional research is necessary before high-accuracy experiments can be performed with the apparatus. Work performed under the auspices of the U.S. Department of Energy by LLNL under contract DE-AC52-07NA27344.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of the Multi-Coincident Bismuth Germanate Oxide Spectrometer at the Nuclear Counting Facility

A multi-detector γ-ray spectroscopy system including 3 high-purity germanium (HPGe) detectors has been developed at the Nuclear Counting Facility at Lawrence Livermore National Laboratory. This system operates not only in conventional singles γ-ray detection mode but also incorporates features like coincidence and anti-coincidence techniques. These advanced detection modes can significantly enhance the system’s sensitivity, making it a powerful tool for isotope identification and quantification, especially for complex samples with high background and overlapping peaks. In this re port, we present a comprehensive performance characterization of the Multi-Coincident Bismuth Oxide Spectrometer (MCBOS) using a variety of sample types, including 60 Co, 48 Sc, and mixed fission product samples. Each sample provides unique tests for the MCBOS capabilities. Additionally, a GEANT4 model of the MCBOS has been generated to aid with the characterization of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Connecting Lunar Meteorites to Source Terrains on the Moon

The number of named stones found on Earth that have proven to be meteorites from the Moon is approx. 180 so far. Since the Moon has been mapped globally in composition and mineralogy from orbit, it has become possible to speculate broadly on the region of origin on the basis of distinctive compositional characteristics of some of the lunar meteorites. In particular, Lunar Prospector in 1998 [1,2] mapped Fe and Th at 0.5 degree/pixel and major elements at 5 degree/pixel using gamma ray spectroscopy. Also, various multispectral datasets have been used to derive FeO and TiO2 concentrations at 100 m/pixel spatial resolution or better using UV-VIS spectral features [e.g., 3]. Using these data, several lunar meteorite bulk compositions can be related to regions of the Moon that share their distinctive compositional characteristics. We then use EPMA to characterize the petrographic characteristics, including lithic clast components of the meteorites, which typically are breccias. In this way, we can extend knowledge of the Moon's crust to regions beyond the Apollo and Luna sample-return sites, including sites on the lunar farside. Feldspathic Regolith Breccias. One of the most distinctive general characteristics of many lunar meteorites is that they have highly feldspathic compositions (Al2O3 approx. 28% wt.%, FeO <5 wt.%, Th <1 ppm). These compositions are significant because they are similar to a vast region of the Moon's farside highlands, the Feldspathic Highlands Terrane, which are characterized by low Fe and Th in remotely sensed data [4]. The meteorites provide a perspective on the lithologic makeup of this part of the Moon, specifically, how anorthositic is the surface and what, if any, are the mafic lithic components? These meteorites are mostly regolith breccias dominated by anorthositic lithic clasts and feldspathic glasses, but they do also contain a variety of more mafic clasts. On the basis of textures, we infer these clasts to have formed by large impacts that excavated and mixed rocks from depth within the lunar crust and possibly the upper mantle. One of the key questions is whether the mafic materials are ferroan or magnesian, which remote sensing does not clearly distinguish, and if mafic, whether they might contain mantlederived components such as olivine (dunite). Many but not all have mainly ferroan mafic components, consistent with a ferroan crustal source that is complementary to the ferroan anorthositic suite and that represents primary magma-ocean-derived feldspathic crust. Meteorites such as ALH 81005 [5] and Shişr 161 [6], however, contain coarse-grained magnesian mafic clasts (Fig. 1a) derived from deeply seated and melted material associated with impact basins. Comparison to LP gamma-ray data [2] supports an origin for magnesian feldspathic meteorites such as these (e.g., Shişr 161) as shown in Fig. 1b. Sayh al Uhaymir (SaU) 169. Another distinctive but much less common composition is represented by relatively mafic impact-melt breccia that is rich in incompatible elements known as KREEP. These meteorites can be related to the western nearside Procellarum KREEP Terrane, especially through a combination of Fe and Th contents. Among the most enriched is SaU 169, which has been related to high- Th impact-melt breccia found at the Apollo 12 site [7]. Through detailed EPMA and ion microprobe analysis we have shown that these two rock types are related in age and origin.

Jolliff, B. L.↗

A Coincident CdTe Detector Array for Enhanced Nuclear Process Monitoring

Nuclear fuel cycle aqueous separation processes desire improved real-time material characterization and process monitoring techniques; gamma coincidence spectroscopy has the potential to meet this need in these high throughput and high radiation environments based on its ability to reduce background noise, thereby enhancing detection limits and improving isotopic identification accuracy. A detector array composed of three CdTe detectors was designed to surround a chemical processing pipe in a reprocessing facility and evaluate the feasibility of passively assaying the nuclear materials flowing though this measurement point. This array uses commercial off the shelf components that are radiation hard and highly efficiency at low energies relevant to actinide photon signatures. Detector efficiency characterizations, coincidence detection, and potential configuration improvements are presented here.

Good, Erin C.↗