Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEAT REGULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

LC-Opt: Benchmarking Reinforcement Learning and Agentic AI for End-to-End Liquid Cooling Optimization in Data Centers

Liquid cooling is critical for thermal management in high-density data centers with the rising AI workloads. However, machine learning-based controllers are essential to unlock greater energy efficiency and reliability, promoting sustainability. We present LC-Opt, a Sustainable Liquid Cooling (LC) benchmark environment, for reinforcement learning (RL) control strategies in energy-efficient liquid cooling of high-performance computing (HPC) systems. Built on the baseline of a high-fidelity digital twin of Oak Ridge National Lab's Frontier Supercomputer cooling system, LC-Opt provides detailed Modelica-based end-to-end models spanning site-level cooling towers to data center cabinets and server blade groups. RL agents optimize critical thermal controls like liquid supply temperature, flow rate, and granular valve actuation at the IT cabinet level, as well as cooling tower (CT) setpoints through a Gymnasium interface, with dynamic changes in workloads. This environment creates a multi-objective real-time optimization challenge balancing local thermal regulation and global energy efficiency, and also supports additional components like a heat recovery unit (HRU). We benchmark centralized and decentralized multi-agent RL approaches, demonstrate policy distillation into decision and regression trees for interpretable control, and explore LLM-based methods that explain control actions in natural language through an agentic mesh architecture designed to foster user trust and simplify system management. LC-Opt democratizes access to detailed, customizable liquid cooling models, enabling the ML community, operators, and vendors to develop sustainable data center liquid cooling control solutions.

Naug, Avisek [Hewlett Packard Enterprise]↗

Assessment of Commercial Building Lighting as a Frequency Regulation Resource

This paper evaluates the potential for automated lighting control as a resource for frequency regulation of the electric grid system in the context of current energy policies, economic incentives, and technological trends. The growing prevalence of renewable energy has increased the need for ancillary services to maintain grid frequency and stability. While demand side resources like heating, ventilating, and air-conditioning systems, as well as water treatment plants are already evaluated as regulation service providers, the potential application to electrical lighting systems has largely been ignored. Yet, aggregations of lighting systems that are retrofitted with intelligent controls could conceivably contribute to frequency regulation services with little impact on user comfort. To further explore the feasibility of lighting potential, this paper explores (1) how lighting control systems are limited by visual comfort perception and acceptability, (2) how such limitations impact the performance of the lighting system as an frequency regulation resource, and (3) how the market potential of lighting systems as demand side resources compares in different regional transmission organizations. Finally, the impact of developing technologies on the application of lighting systems for frequency regulation is discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Gravity and thermoregulation: metabolic changes and circadian rhythms

Gravity appears to alter thermoregulation through changes in both the regulated level of body temperature and the rhythmic organization of temperature regulation. Gravity has been hypothesized to have an associated metabolic cost. Increased resting energy expenditure and dietary intake have been observed in animals during centrifuge experiments at hypergravity. Thus far, only animals have shown a corresponding reduction in metabolism in microgravity. Altered heat loss has been proposed as a response to altered gravitational environments, but remains documented only as changes in skin temperature. Changes in circadian timing, including the body temperature rhythm, have been shown in both hypergravity and microgravity, and probably contribute to alterations in sleep and performance. Changes in body temperature regulation may result from circadian disturbance, from the direct or indirect actions of gravity on the regulated temperature, or from changes in thermoregulatory effectors (heat production and heat loss) due to altered gravitational load and convective changes. To date, however, we have little data on the underlying thermoregulatory changes in altered gravity, and thus the precise mechanisms by which gravity alters temperature regulation remain largely unknown.

Non-NASA Center↗

Nonlinear burn control in ITER using adaptive allocation of actuators with uncertain dynamics

Abstract ITER will be the first tokamak to sustain a fusion-producing, or burning, plasma. If the plasma temperature were to inadvertently rise in this burning regime, the positive correlation between temperature and the fusion reaction rate would establish a destabilizing positive feedback loop. Careful regulation of the plasma’s temperature and density, or burn control, is required to prevent these potentially reactor-damaging thermal excursions, neutralize disturbances and improve performance. In this work, a Lyapunov-based burn controller is designed using a full zero-dimensional nonlinear model. An adaptive estimator manages destabilizing uncertainties in the plasma confinement properties and the particle recycling conditions (caused by plasma–wall interactions). The controller regulates the plasma density with requests for deuterium and tritium particle injections. In ITER-like plasmas, the fusion-born alpha particles will primarily heat the plasma electrons, resulting in different electron and ion temperatures in the core. By considering separate response models for the electron and ion energies, the proposed controller can independently regulate the electron and ion temperatures by requesting that different amounts of auxiliary power be delivered to the electrons and ions. These two commands for a specific control effort (electron and ion heating) are sent to an actuator allocation module that optimally maps them to the heating actuators available to ITER: an electron cyclotron heating system (20 MW), an ion cyclotron heating system (20 MW), and two neutral beam injectors (16.5 MW each). Two different actuator allocators are presented in this work. The first actuator allocator finds the optimal mapping by solving a convex quadratic program that includes actuator saturation and rate limits. It is nonadaptive and assumes that the mapping between the commanded control efforts and the allocated actuators (i.e. the effector model) contains no uncertainties. The second actuator allocation module has an adaptive estimator to handle uncertainties in the effector model. This uncertainty includes actuator efficiencies, the fractions of neutral beam heating that are deposited into the plasma electrons and ions, and the tritium concentration of the fueling pellets. Furthermore, the adaptive allocator considers actuator dynamics (actuation lag) that contain uncertainty. This adaptive allocation algorithm is more computationally efficient than the aforementioned nonadaptive allocator because it is computed using dynamic update laws so that finding the solution to a static optimization problem is not required at every time step. A simulation study assesses the performance of the proposed adaptive burn controller augmented with each of the actuator allocation modules.

Physics↗

Integrated Security-Safety Consequence Study of a Heat Pipe Reactor

This report presents a preliminary demonstration of integrated security/safety consequence modeling to support potential physical security exemption justifications under the new Title 10 Code of Federal Regulations Part 53 licensing pathway, which allows exemptions if sabotage-induced radiological consequences do not exceed 25 rem at the site boundary two hours after release without mitigative actions. A hypothetical heat pipe microreactor subjected to direct sabotage by a 150 lbs. TNT-equivalent high-explosive device was analyzed using a simplified radionuclide release estimate based on DOE-HDBK-3010-94, implemented in the MELCOR severe accident analysis code to model release transport and attenuation through reactor/building compartments, with MELCOR outputs coupled to MACCS to compute offsite doses and the distance-to-threshold metric D 25rem . Six scenarios were evaluated to examine sensitivities to release pathway/building configuration and radionuclide form (vapor versus aerosols with different size distributions). Results show a positive correlation between leak path factor and D 25rem and indicate that reactor building compartmentalization can substantially reduce consequences (a single-story configuration reduced D 25rem by roughly an order of magnitude relative to a cavity-only configuration), while vapor versus aerosol assumptions had limited impact for the modeled two-story case on the spatial grid used.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effects of Heat Pipe Failures in Microreactors

Microreactors provide new opportunities for nuclear reactor applications given their long-lived fuel source, compact size, portability, reliability as it relates to safety and their self-regulating nature. To take advantage of these opportunities there are technological challenges that need to be overcome. One advancing technology often used in conjunction with microreactor designs are heat pipes, which are used for heat removal from the reactor core to the power conversion system. Heat pipes are a substitute for the traditional system in which the same fluid used as coolant in the reactor is then used as the working fluid in the power conversion system. This document describes how heat pipes operate, what happens when a heat pipe fails, and what codes can be used to simulate the results. Our analyses show that a single/double heat pipe failure results in a temperature increase of 15-50°C respectively in surrounding heat pipes. Heat pipe microreactors could be easily designed such that this increase is within the maximum parameters allowable for safety and does not result in cascading heat pipe failure. Thus, such failures do not lead to severe degradation of the reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal analyses of power subsystem components

The hiatus in the Space Shuttle (Orbiter) program provided time for an in-depth examination of all the subsystems and their past performance. Specifically, problems with reliability and/or operating limits were and continue to be of major engineering concern. The Orbiter Auxiliary Power Unit (APU) currently operates with electric resistance line heaters which are controlled with thermostats. A design option simplification of this heater subsystem is being considered which would use self-regulating heaters. A determination of the properties and thermal operating characteristics of these self-regulating heaters was needed. The Orbiter fuel cells are cooled with a freon loop. During a loss of external heat exchanger coolant flow, the single pump circulating the freon is to be left running. It was unknown what temperature and flow rate transient conditions of the freon would provide the required fuel cell cooling and for how long. The overall objective was the development of the thermal characterization and subsequent analysis of both the proposed self-regulating APU heater and the fuel cell coolant loop subsystem. The specific objective of the APU subsystem effort was to determine the feasibility of replacing the current heater and thermostat arrangement with a self-regulating heater. The specific objective of the fuel cell coolant subsystem work was to determine the tranient coolant temperature and associated flow rates during a loss-of-external heat exchanger flow.

Morehouse, Jeffrey H.↗

Reducing the Flow Maldistribution in Heat Exchangers through a Novel Polymer Manifold: Numerical Evaluation

The maldistribution of working fluid is one of the issues in heat exchangers that causes a reduction in performance of not only the heat exchanger but also the entire HVAC system. One of the methods to reduce such maldistribution is to improve manifold design to evenly distribute the flow. In the present work, an advanced maldistribution reduction manifold, which was based on a preliminary maldistribution reduction manifold, was designed to further improve the flow distribution in the heat exchanger. In the design, spiral baffles are used to create vortices in the tubes to regulate the flow in each tube. The design also keeps the tubes away from the manifold inlet to avoid direct flow from the inlet. Due to the complexity, the design of the advanced maldistribution reduction manifold is for AM only, which cannot be fabricated by traditional manufacturing. To evaluate the design, a computational fluid dynamic model is developed to study flow distribution in heat exchanger manifolds. The simulation results reveal that the relative standard deviation of the tubes in the advanced maldistribution reduction design is half of the preliminary maldistribution reduction design and about 1/20 of the reference design.

42 ENGINEERING↗

Dynamic Simulation Modeling and Control of a Desiccant Assisted Direct-expansion Air Handling Unit

Desirable built environments demand simultaneous regulation of thermal comfort and indoor air quality (IAQ) with energy-efficient operation of heating, ventilation and air conditioning (HV AC) systems, which involves controls of temperature, humidity and airborne contaminants simultaneously. This paper presents the efforts of dynamic modeling and initial development control strategy for a desiccant-assisted multi-functional air handling unit (AHU) coupled with a direct-expansion rooftop unit (RTU) system, which aims to achieve multiple functions for indoor environment conditioning with energy efficient control. The RTU-AHU system includes a desiccant wheel for dehumidification and a conceptual direct air capture (DAC) filtering device for CO2 regulation. A Modelica-based dynamic model is developed for this conceptual system, and a simple decentralized control strategy is designed, which combines a differential-enthalpy based AHU return-air ratio control, a demand-controlled ventilation, and supply-air temperature humidity control via the RTU and DW controls. The proposed control method is evaluated with the Modelica simulation model for a selected set of scenarios

Pan, Chao↗

The cis-regulatory codes of response to combined heat and drought stress in Arabidopsis thaliana

Abstract Plants respond to their environment by dynamically modulating gene expression. A powerful approach for understanding how these responses are regulated is to integrate information about cis-regulatory elements (CREs) into models called cis-regulatory codes. Transcriptional response to combined stress is typically not the sum of the responses to the individual stresses. However, cis-regulatory codes underlying combined stress response have not been established. Here we modeled transcriptional response to single and combined heat and drought stress in Arabidopsis thaliana. We grouped genes by their pattern of response (independent, antagonistic and synergistic) and trained machine learning models to predict their response using putative CREs (pCREs) as features (median F-measure = 0.64). We then developed a deep learning approach to integrate additional omics information (sequence conservation, chromatin accessibility and histone modification) into our models, improving performance by 6.2%. While pCREs important for predicting independent and antagonistic responses tended to resemble binding motifs of transcription factors associated with heat and/or drought stress, important synergistic pCREs resembled binding motifs of transcription factors not known to be associated with stress. These findings demonstrate how in silico approaches can improve our understanding of the complex codes regulating response to combined stress and help us identify prime targets for future characterization.

Azodi, Christina B.↗

Ultra-high temperature stability Joule-Thomson cooler with capability to accomodate pressure variations

A Joule-Thomson cryogenic refrigeration system capable of achieving high temperature stabilities in the presence of varying temperature, atmospheric pressure, and heat load is provided. The Joule-Thomson cryogenic refrigeration system includes a demand flow Joule-Thomson expansion valve disposed in a cryostat of the refrigeration system. The expansion valve has an adjustable orifice that controls the flow of compressed gas therethrough and induces cooling and partial liquefaction of the gas. A recuperative heat exchanger is disposed in the cryostat and coupled to the expansion valve. A thermostatically self-regulating mechanism is disposed in the cryostat and coupled to the J-T expansion valve. The thermostatically self-regulating mechanism automatically adjusts the cross sectional area of the adjustable valve orifice in response to environmental temperature changes and changes in power dissipated at a cold head. A temperature sensing and adjusting mechanism is coupled to a cold head for adjusting the temperature of the cold head in response to the change in heat flow in the cold head. The temperature sensing and adjusting mechanism comprises a temperature sensitive diode, a wound wire heater, and an electrical feedback control circuit coupling the diode to the heater. An absolute pressure relief valve is interposed between the output of the cryostat and an exhaust port for maintaining a constant exhaust temperature in the refrigerating system, independent of the changes in atmospheric pressure.

Bard, Steven↗

LHCSR1 Functions as a Dimmer Switch for Light Harvesting

In oxygenic photosynthesis, high light leads to a set of photoprotective processes, known as nonphotochemical quenching, that are required for fitness. In moss and algae, the pigment−protein complex, light-harvesting stress-related (LHCSR), is crucial for photoprotection. Acidification of the thylakoid lumen under high light triggers the activation of LHCSR and the conversion of the xanthophyll violaxanthin into zeaxanthin, which is found within LHCSR. These interrelated molecular components combine to turn on a safety valve that dissipates excess energy as heat. Previous studies of detergent-solubilized LHCSR1 found that pH and zeaxanthin regulate distinct quenching sites via the protein conformation. However, protein function in the native membrane environment can be significantly different. In this work, we applied single-molecule fluorescence spectroscopy to LHCSR1 in membrane nanodiscs. The membrane environment enhanced total quenching, regardless of pH or zeaxanthin-binding. pH-dependent quenching was still observed whereas zeaxanthin-dependent quenching was suppressed. Conformational changes also increased in the membrane, establishing that the local environment can change the nature of the equilibrium between light harvesting and photoprotection.

Hoffmann, Madeline P. [Massachusetts Inst. of Tech↗

Real-time avoidance of the L-mode and H-mode density limit via machine-learned stability metrics

Reliable operation of burning plasma tokamaks will require robust control strategies to avoid macroscopic instability limits such as the L-mode and H-mode density limits (LDL, HDL). In this work, we explore closed-loop avoidance of these phenomena at DIII-D using machine-learned risk metrics. Feedback control is implemented via the ‘DL Supervisor’ scheme, which regulates the chosen risk metric by reducing the density target or increasing NBI heating in real-time. Using the LDL 25 risk metric, the LDL is reproducibly suppressed. We also introduce an HDL risk metric in this study, HDL 25 , which reduces the False Positive Rate by 2x compared to the Greenwald fraction. Applying this scaling to a plasma current ramp-down, we successfully avoid an HDL-driven H/L back-transition. These experiments constitute the first demonstration of real-time DL avoidance using machine-learned risk metrics. These instability metrics outline a path to safer high-density operation, more reliable ramp-down scenarios, and improved off-normal control for next-step devices such as ITER and SPARC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cold Helium Gas Pressurization For Spacecraft Cryogenic Propulsion Systems

To reduce the dry mass of a spacecraft pressurization system, helium pressurant may be stored at low temperature and high pressure to increase mass in a given tank volume. Warming this gas through an engine heat exchanger prior to tank pressurization both increases the system efficiency and simplifies the designs of intermediate hardware such as regulators, valves, etc. since the gas is no longer cryogenic. If this type of cold helium pressurization system is used in conjunction with a cryogenic propellant, though, a loss in overall system efficiency can be expected due to heat transfer from the warm ullage gas to the cryogenic propellant which results in a specific volume loss for the pressurant, interpreted as the Collapse Factor. Future spacecraft with cryogenic propellants will likely have a cold helium system, with increasing collapse factor effects as vehicle sizes decrease. To determine the collapse factor effects and overall implementation strategies for a representative design point, a cold helium system was hotfire tested on the Integrated Cryogenic Propulsion Test Article (ICPTA) in a thermal vacuum environment at the NASA Glenn Research Center Plum Brook Station. The ICPTA vehicle is a small lander-sized spacecraft prototype built at NASA Johnson Space Center utilizing cryogenic liquid oxygen/liquid methane propellants and cryogenic helium gas as a pressurant to operate one 2,800lbf 5:1 throttling main engine, two 28lbf Reaction Control Engines (RCE), and two 7lbf RCEs (Figure 1). This vehicle was hotfire tested at a variety of environmental conditions at NASA Plum Brook, ranging from ambient temperature/simulated high altitude, deep thermal/high altitude, and deep thermal/high vacuum conditions. A detailed summary of the vehicle design and testing campaign may be found in Integrated Cryogenic Propulsion Test Article Thermal Vacuum Hotfire Testing, AIAA JPC 2017.

Morehead, Robert L.↗

Design and Analysis of Liquid Lithium Plasma Facing Components

In this study, liquid metal (LM) on plasma-facing components (PFCs) creates a renewable protective cover enhancing power exhaust and protecting the solid substrate. Additionally, energy confinement improvement through particle pumping can be achieved in the case of liquid lithium (LL). A new variant of PFCs was recently introduced at Princeton Plasma Physics Laboratory (PPPL) where a porous wall is used to stabilize the LM surface, while using magnetohydrodynamic (MHD) drive to push the LM flow inside the component. This arrangement allows efficient heat exhaust, and enhanced control of the LM surface temperature, leading to spatial control of evaporation and condensation of LL on the plasma interface. This feature is particularly attractive when vapor shielding is introduced to allow heat flux redistribution. This system has the advantage that as the heat flux increases, the evaporation rate will increase, while decreasing heat flux will decrease the evaporation rate of lithium, ideally creating a feedback effect which could self-regulate the amount of lithium evaporated. Analytical and numerical models for LL PFCs were developed in PPPL. To calculate the target temperature distribution for the case of evaporation from the divertor, we apply an iterative process allowing two-way coupling between the fluid-kinetic analysis of plasma using SOLPS-ITER code and the flow and heat transfer analysis of the PFC using an analytical model. In the last stage, the results are validated using computational fluid dynamics (CFD) analysis with customized version of the CFX code from ANSYS. CFX was modified at PPPL to allow MHD analysis at the high magnetic field typical for fusion applications. Results of the analysis for NSTX-U tokamak conditions will be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low-temperature Leidenfrost-like jumping of sessile droplets on microstructured surfaces

The Leidenfrost effect—the levitation and hovering of liquid droplets on hot solid surfaces—generally requires a sufficiently high substrate temperature to activate liquid vaporization. Here, in this paper, we report the modulation of Leidenfrost-like jumping of sessile water microdroplets on micropillared surfaces at a relatively low temperature. Compared to traditional Leidenfrost effect occurring above 230 °C, the fin-array-like micropillars enable water microdroplets to levitate and jump off the surface within milliseconds at a temperature of 130 °C by triggering the inertia-controlled growth of individual vapour bubbles at the droplet base. We demonstrate that droplet jumping, resulting from momentum interactions between the expanding vapour bubble and the droplet, can be modulated by tailoring of the thermal boundary layer thickness through pillar height. This enables regulation of the bubble expansion between the inertia-controlled mode and the heat-transfer-limited mode. The two bubble-growth modes give rise to distinct droplet jumping behaviours characterized by constant velocity and constant energy regimes, respectively. This heating strategy allows the straightforward purging of wetting liquid droplets on rough or structured surfaces in a controlled manner, with potential applications including the rapid removal of fouling media, even when located in surface cavities.

42 ENGINEERING↗

Selective electrified polyethylene upcycling by pore-modulated pyrolysis

Plastic waste is a increasing problem, accumulating in landfills and the environment. Pyrolysis is a promising and industrially relevant approach for transforming plastic waste into value-added chemicals. However, the selectivity and yield of traditional plastic pyrolysis are poor, with products featuring broad molar mass distributions. Here we report a highly selective, energy-efficient and catalyst-free pyrolysis method that can upcycle plastic into value-added chemicals via pore-modulated pyrolysis. Using a Joule-heated carbon column, we demonstrate the pivotal role of the reactor’s graded porous structure in decreasing the polydispersity of the reaction intermediates, enabling high product selectivity and yield. The decreasing pore size of the reactor modulates the mass transport in an apparent gating effect—preventing high-molar-mass species from exiting the reactor before sufficient pyrolysis has occurred. Using polyethylene as a model reactant, we demonstrate a high yield of 65.9 ± 5.2% and up to 80.8% selectivity toward value-added aviation fuel precursor (C8–C18 hydrocarbons) without the use of any catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microbial responses to long-term warming differ across soil microenvironments

Soil carbon loss is likely to increase due to climate warming, but microbiomes and microenvironments may dampen this effect. In a 30-year warming experiment, physical protection within soil aggregates affected the thermal responses of soil microbiomes and carbon dynamics. In this study, we combined metagenomic analysis with physical characterization of soil aggregates to explore mechanisms by which microbial communities respond to climate warming across different soil microenvironments. Long-term warming decreased the relative abundances of genes involved in degrading labile compounds (e.g. cellulose), but increased those genes involved in degrading recalcitrant compounds (e.g. lignin) across aggregate sizes. These changes were observed in most phyla of bacteria, especially for Acidobacteria, Actinobacteria, Bacteroidetes, Chloroflexi, and Planctomycetes. Microbial community composition was considerably altered by warming, leading to declined diversity for bacteria and fungi but not for archaea. Microbial functional genes, diversity, and community composition differed between macroaggregates and microaggregates, indicating the essential role of physical protection in controlling microbial community dynamics. Our findings suggest that microbes have the capacity to employ various strategies to acclimate or adapt to climate change (e.g. warming, heat stress) by shifting functional gene abundances and community structures in varying microenvironments, as regulated by soil physical protection.

59 BASIC BIOLOGICAL SCIENCES↗