Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat resilience”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Design Considerations to Ensure Robustness of the ITER Diagnostics Residual Gas Analyzer

Increasing robustness of the ITER diagnostic residual gas analyzer (DRGA) is critical for the potential control of plasma heating and fuel-cycle processing. Robustness is a requirement for a diagnostic to have a control function. The DRGA is a multisensor diagnostic system capable of resolving isotopic compositions of hydrogen and helium as well as other heavier elements and compounds. The divertor-specific DRGA system is intended to measure the composition of gases in the ITER subdivertor region and midplane. Its analysis station will be located in a port cell at the divertor level. From there, it will sample a slip stream of gas from the cryogenic pump duct. It will then exhaust into a shared roughing line where helium or other light gas impurities, some potentially from other diagnostic systems, are likely to be present. In order to provide reliable measurements, the DRGA must be robust in areas such as plasma optical emission source geometry for a compact design, mitigation of back-streaming from light gases and resilience to the ITER port cell environment, and radiation hardening of the DRGA electronics. By incorporating robustness into the design, areas of plasma heating and fuel-cycle control may be explored with the DRGA for ITER and next-generation fusion devices.

Quinlan, Brendan↗

Guest Editorial: Special Section on Sustainable Energy for Enhancing Grid Resiliency

Extreme weather threatens lives, disables communities, and devastates energy generation, transmission, and distribution systems. These extreme events are likely to become more frequent or more intense due to climate change. Energy networks have shown significant vulnerability during record hurricanes, deadly heat waves, destructive wildfires, and winter storms in the past few years. Because of the energy transition process, modern power grids will feature a high penetration level of the use of renewable resources. The adoption of renewable energy and the rise of omnidirectional power delivery mean that our energy network is more decentralized than ever. In this new environment, grid operation becomes more complex, and achieving resiliency is more difficult than in the past. Many utilities are seeking the latest technologies to improve energy security and responsiveness to severe events. On the one hand, sustainable energy resources can provide emergency power and assist grid restoration in disastrous events. On the other hand, their volatility, susceptibility, interdependency, and other unique features must be carefully considered when being used for grid resilience enhancement. This special section brings together 22 papers that range from innovative research advances tackling fundamental challenges of achieving more resilient grids to real-world demonstrations of leveraging sustainable energy resources to enhance grid resiliency. These papers can be categorized into three groups.

climate change↗

The Open-Ocean Sensible Heat Flux and Its Significance for Arctic Boundary Layer Mixing During Early Fall

The increasing ice-free area during late summer has transformed the Arctic to a climate system with more dynamic boundary layer (BL) clouds and seasonal sea ice growth. The open-ocean sensible heat flux, a crucial mechanism of excessive ocean heat loss to the atmosphere during the fall freeze season, is speculated to play an important role in the recently observed cloud cover increase and BL instability. However, lack of observations and understanding of the resilience of the proposed mechanisms, especially in relation to meteorological and interannual variability, has left a poorly constrained BL parameterization scheme in Arctic climate models. In this study, we use multiyear Japanese cruise-ship observations from RV Mirai over the open Arctic Ocean to characterize the surface sensible heat flux (SSHF) during early fall and investigate its contribution to BL turbulence. It is found that mixing by SSHF is favored during episodes of high surface wind speed and is also influenced by the prevailing cloud regime. The deepest BLs and maximum ocean-atmosphere temperature difference are observed during cold air advection (associated with the stratocumulus regime), yet, contrary to previous speculation, the efficiency of sensible heat exchange is low. On the other hand, the SSHF contributes significantly to BL mixing during the uplift (low pressure) followed by the highly stable (stratus) regime. Overall, it can explain 10 of the open ocean BL height variability, whereas cloud-driven (moisture and radiative) mechanisms appear to be the other dominant source of convective turbulence. Nevertheless, there is strong interannual variability in the relationship between the SSHF and the BL height which can be intensified by the changing occurrence of Arctic climate patterns, such as positive surface wind speed anomalies and more frequent conditions of uplift. This study highlights the need for comprehensive BL observations like the RV Mirai for better understanding and predicting the dynamic nature of the Arctic climate.

boundary layer↗

An HPC-Based Hydrothermal Finite Element Simulator for Modeling Underground Response to Community-Scale Geothermal Energy Production

Geothermal heat, as renewable energy, shows great advantage with respect to its environmental impact due to its significantly lower CO2 emissions than conventional fossil fuel. Open and closed-loop geothermal heat pumps, which utilize shallow geothermal systems, are an efficient technology for cooling and heating buildings, especially in urban areas. Integrated use of geothermal energy technologies for district heating, cooling, and thermal energy storage can be applied to optimize the subsurface for communities to provide them with multiple sustainable energy and community resilience benefits. The utilization of the subsurface resources may lead to a variation in the underground environment, which might further impact local environmental conditions. However, very few simulators can handle such a highly complex set of coupled computations on a regional or city scale. We have developed high-performance computing (HPC) based hydrothermal finite element (FE) simulator that can simulate the subsurface and its hydrothermal conditions at a scale of tens of km. The HPC simulator enables us to investigate the subsurface thermal and hydrologic response to the built underground environment (such as basements and subways) at the community scale. In this study, a coupled hydrothermal simulator is developed based on the open-source finite element library deal.II. The HPC simulator was validated by comparing the results of a benchmark case study against COMSOL Multiphysics, in which Aquifer Thermal Energy Storage (ATES) is modeled and a process of heat injection into ATES is simulated. The use of an energy pile system at the Treasure Island redevelopment site (San Francisco, CA, USA) was selected as a case study to demonstrate the HPC capability of the developed simulator. The simulator is capable of modeling multiple city-scale geothermal scenarios in a reasonable amount of time.

Sun, Xiang↗

Thermal Reservoir Networks for Modularly Expandable Thermal Microgrids

The Department of Defense (DoD) faces the substantial challenge of cost-effectively retrofitting one to two installations per month, each comprising approximately 1,000 buildings, to improve resilience, reduce energy consumption, and enhance energy supply security. Achieving these objectives requires optimal system selection and effective risk mitigation during system integration. To address this need, we introduce Platform-Based Design (PBD), a structured, hierarchical methodology adapted from other industrial sectors to the domain of energy system retrofits. We demonstrate the effectiveness of PBD through a techno-economic feasibility study comparing geothermal-coupled thermal energy networks (TENs) with conventional energy systems for heating, cooling, and powering 17 buildings at Joint Base Andrews (JBA) in Maryland. Our analysis illustrates that the PBD approach enables rigorous, data-driven, sequential decision making, resulting in a family of Pareto-optimal systems, among which the TEN emerged as the most promising solution. The selected TEN design integrates geothermal borefields, heat recovery heat pumps, photovoltaic (PV) arrays, and battery storage. Compared to the baseline system – gas heating combined with air-source chillers – the proposed TEN reduces annual imported energy by 74% and peak electricity demand by 45%, achieves a levelized cost of energy of $\$0.210$/kWh, and substantially enhances resilience. Life-cycle costs increase by approximately 6%, and initial investment costs are about 2.5 times higher than the baseline. However, if central plant infrastructure, district loops, and utility-scale PV and battery systems are privately funded and operated, the initial investment would fall below the baseline system cost. Critical to achieving these significant performance improvements were detailed nonlinear dynamic simulations coupling geothermal heat transfer, energy system operation, and realistic feedback control logic. These simulations identified essential design modifications and control strategy refinements that substantially reduced energy use, peak demand, and compressor shortcycling, thereby improving durability and reliability—issues that would have been significantly more expensive to resolve during operation. Additionally, the verification step highlighted sensitivities to key design parameters that could reduce initial investment by approximately $\$2$ million and reduce annual life-cycle costs more than $\$300,000$. We recommend adopting the PBD methodology for future feasibility studies and TEN pilot projects to gain valuable operational experience. Furthermore, we recommend that DoD invest in transferring and scaling the PBD methodology to other installations. This entails developing standardized computational frameworks and component libraries as well as training industry in conducting PBD. Such investments would enable rapid, robust, reliable, and cost-effective retrofits, supporting DoD’s ambitious energy system modernization goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resilient stellarator divertor characteristics in the Helically Symmetric eXperiment

Resilient divertor features connected to open chaotic edge structures in the Helically Symmetric eXperiment are investigated. For the first time, an expanded vessel wall was considered that would give space for implementation of a physical divertor target structure. The analysis was done for four different magnetic configurations with very different chaotic plasma edges. A resilient plasma wall interaction pattern was identified across all configurations. This manifests as qualitatively very similar footprint behavior across the different plasma equilibria. Overall, the resilient field lines of interest with high connection length L C lie within a helical band along the wall for all configurations. This resiliency can be used to identify the best location of a divertor. The details of the magnetic footprint’s resilient helical band is subject to specific field line structures which are linked to the penetration depth of field lines into the plasma and directly influence the heat and particle flux patterns. The differences arising from these details are characterized by introducing a new metric, the minimum radial connection min $(\delta_N)$ of a field line from the last closed flux surface. The relationship, namely the deviation from a scaling law, between min $(\delta_N)$ and L C of the field lines in the plasma edge field line behavior suggests that the field lines are associated with structures such as resonant islands, cantori, and turnstiles. This helps determine the relevant magnetic flux channels based on the radial location of these chaotic edge structures and the divertor target footprint. These details will need to be taken into account for resilient divertor design.

divertor↗

Comparative Analysis of Heat Exchangers for High Temperature High Pressure Helium Component Testing

Helium gas loops have been designed and built to gain a better understanding of the gas thermohydraulic phenomena that take place in a helium system. Some of these loops are used for validation and testing of components for high temperature gas-cooled reactors (HTGRs). However, most of them operate at lower pressure and temperature than an HTGR. While these loops can provide valuable information about gas-cooled reactor components, the operating envelope of the experiment is constrained by the maximum operating conditions of the helium loop. In response to the lack of an experimental facility that can provide the infrastructure needed to validate and test components at nominal pressures and temperatures of HTGRS, the HElium Component Testing Out-of-pile Research (HECTOR) facility was designed at Idaho National Laboratory with the assistance of University of Idaho and Walsh Engineering. With the capability to test at temperatures up to 800°C and pressures of 8MPa, HECTOR serves as a critical tool for the advancement of HTGR technology. The facility's primary role is to provide a controlled, high-fidelity environment for the assessment of component resilience and efficiency under nominal HTGR conditions. In the quest to enhance the efficiency and performance of HECTOR, a comparative analysis of three distinct types of heat exchangers—shell and tube, offset strip fin, and printed-circuit—was conducted, focusing primarily on two critical metrics: the required surface area and pressure drop characteristics. The shell and tube heat exchanger, renowned for its robust design and widespread industrial application, was evaluated against the offset strip fin and the cuttingedge printed-circuit heat exchangers, both of which are lauded for their compactness and thermal effectiveness. This comparative study aims to provide detailed insights into the thermal management capabilities of each heat exchanger type under the conditions inherent to HECTOR, thereby facilitating an informed selection for systems demanding high operational integrity and efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ORNL Campus Sustainability and Decarbonization using Waste Heat Recovery from the Oak Ridge Leadership Computing Facility’s High-Performance Computing Data Center

Heat pumps are a clean and efficient technology that can be powered by renewable electricity to transfer heat using a refrigerant from one place to another by different heat sources, making buildings clean and environmentally friendly. With the support of the ORNL Laboratory Modernization Division, this project explored and evaluated an innovative solution that uses water-water cost-effective midtemperature heat pump (MTHP) technology to leverage the low-grade waste heat from ORNL Frontier and the data center to deliver 85°C hot water, which replaces hot steam generated using natural gas combustion boilers for water heating or space heating in the buildings of ORNL campus. Two scenarios were studied. In the first scenario, which considered the 5600-5700-5800 complex only, Carrier’s commercial 1,000 kW MTHP technology achieves more than 6,640 MWh/year energy savings, an emission reduction of 858 TCO2e/year CO2, and a payback time of 4.85 years. In the second scenario, which considered the 5600-5700-5800 complex and Buildings 5100, 5200, and 5300, the CO2 emission reduction is 1,483 TCO2e/year, the operating cost savings are $0.21 million annually, and the payback time is 3.74 years. Additionally, a comprehensive HP ShowCase Tool was developed for evaluating the optimal solution to improve sustainability and decarbonization of the buildings on the ORNL campus. The tool is an Excel-based tool integrated with VBA (Visual Basic for Applications) coding. The tool includes collected ORNL campus building information and an MTHP library, which comprises collected commercial and ORNL-defined MTHPs. The tool was used to evaluate the sustainability and decarbonization of the ORNL campus. The tool can be widely used or referenced for heat pump solutions and building decarbonization renovation strategies to modernize ORNL facilities and energy use–intensive equipment to enable efficient, sustainable, and resilient operations in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Equitable Energy Transition Planning in Holyoke, Massachusetts: A Technical Analysis for Strategic Gas Decommissioning and Grid Resiliency

Buildings account for 30% of the emissions in Massachusetts and are the largest source of emissions in the United States, along with transportation. Pipeline-delivered methane gas is the dominant heating source in Massachusetts, representing 51% of heating in the state. The current gas network in Massachusetts and across many other US states is aging, a relic of the coal gas era, with thousands of miles of cast iron and unprotected steel pipes that are considered leak prone. Even newer plastic pipes are subject to degradation and in need of replacement, an upgrade that averages $2.8 million per mile of pipeline replacement across investor-owned utilities in Massachusetts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimum Operation of Microgrid Systems that Employ PV Solar and Battery Systems

On a global scale, over 1.3 billion lack access to electricity (85% in rural areas), and approximately 2.8 billion people rely on traditional biomass for cooking. The World Health Organization estimates that household air pollution from inefficient stoves causes more premature deaths than malaria, tuberculosis, and HIV/AIDS. Increasing demand for energy has led to dramatic increases in emissions. The need for reliable electricity and limiting emissions drives research on Resilient Hybrid Energy Systems (RHESs), which provide cleaner energy by combining wind, solar, and biomass energy with traditional fossil energy, increasing production efficiency and reliability and reducing generating costs and emissions. Microgrids have been shown as an efficient means of implementing RHESs, with some focused mainly on reducing the environmental impact of electric power generation. The technical challenges of designing, implementing, and applying microgrids involve conducting a cradle-to-grave Life Cycle Analysis (LCA) to evaluate these systems’ environmental and economic performance under diverse operating conditions to evaluate resiliency. A sample RHES was developed and used to demonstrate the implementation in rural applications, where the system can provide reliable electricity for heating, cooling, lighting, and pumping clean water. The model and findings can be utilized by other regions around the globe facing similar challenges.

Nagapurkar, Prashant↗

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS↗

Modeling the Impact of Flexible CHP on the Future Electric Grid In California

Combined heat and power (CHP) systems provide electricity and process heat at more than 4,400 industrial and commercial facilities across the United States. Typically fueled with natural gas, a CHP system combines a prime mover (such as a reciprocating engine) with a generator and heat recovery equipment, allowing operation at very high efficiencies (65–85%). Traditionally, CHP systems have been configured to serve local electrical and thermal loads at the sites where they are deployed. Units are sized to ensure a high capacity factor for the equipment, and the electricity generated tends to be used on site. CHP units in the United States already generate over 12% of the nation’s electricity. However, CHP’s potential benefits could be much greater if power generated could be used beyond the site, because the analysis was performed under the assumption that sites could use all the thermal output. Analysis of a few key sectors confirmed that this assumption is valid (for more information, see Appendix E). Those benefits could include improved grid reliability and resilience, as well as lower-cost options for providing energy and other grid services. The potential benefits also align well with grid modernization objectives, as shown in Combined heat and power (CHP) systems provide electricity and process heat at more than 4,400 industrial and commercial facilities across the United States., and greater electrification of loads, driven by carbon reduction priorities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Thermal Analysis of a Solid Particle Light-Trapping Planar Cavity Receiver Using Computational Fluid Dynamics

Concentrated solar power (CSP) is one of the most effective ways of harnessing solar power to create efficient, durable, and resilient energy systems. This study entails thermal modeling and analysis of a novel central tower receiver configuration. This receiver uses solid particles as the heat transfer fluid (HTF), a promising option for third-generation CSP systems. The configuration considered here is the light-trapping planar cavity receiver (LTPCR) introduced by the National Renewable Energy Laboratory. While heat transfer studies of various LTPCR subsystems have been done, system-level thermal analysis of the LTPCR receiver has not been attempted. This study also presents important sensitivity analyses of the operating parameters of the CSP system, which can help guide the design of future central tower receivers. This study employs Ansys Fluent as a computational fluid dynamics (CFD) tool to model fluid dynamics and heat transfer in the receiver, intending to quantify its thermal performance. The model seamlessly integrates Monte Carlo ray tracing data, which generates absorbed solar flux profiles from the heliostat field design, with the heat transfer characteristics of the fluidized particle bed. This unified model is designed to accurately predict the thermal behavior of the LTPCR. Analysis of preliminary results reveals that the primary loss mechanisms are radiative and natural convective losses, in that order. Based on observations from a baseline case, several strategies are suggested and numerically tested. These solutions include selective cooling of high-temperature regions and manipulation of particle bed parameters. Selective cooling of high-temperature regions reduced the peak temperature by 151 degrees C and decreased thermal losses by 0.9%. Improving the particle-wall heat transfer coefficient (P-W HTC) of the particle bed decreased the thermal losses by 1.7% and decreased the peak temperatures by 57 degrees C. Decreasing the particle inlet temperature (PIT) also reduced thermal losses by 3.5% and decreased peak temperatures by 29 degrees C. Compounding these strategies improved the thermal losses of the receiver from 13.5% in the baseline case to 7.5%. Additionally, the study explores the variation in thermal performance across different locations of the receiver, where a variation of thermal losses from 12.9% to 17.3% is found. This allows a comprehensive evaluation of potential improvements in efficiency and temperature management.

computational fluid dynamics↗

Energy Impact of Radiative Cooling Paints in Warehouses Under Various United States Climates

Although radiative cooling research is widely found in the literature, no comprehensive study has yet been conducted on the impact of novel radiant cooling (>0.91 reflectance) on the energy efficiency of warehouses. Here, in this work, we develop three building models based on a Department of Energy prototype warehouse model using trnsys, representing a typical warehouse with a black roof, a typical warehouse with a white roof, and a warehouse with novel radiative cooling (RC) paint on its roof. These models are run for 15 different cities, each representative of a different ASHRAE climate zone, to better understand the impact of RC in many different climates. It was found that an RC-coated roof in a warehouse could reduce the building's annual heating, ventilation, and air conditioning (HVAC) loads by up to 14.11 kWh/m 2 of the roof area compared to a black roof, resulting in a maximum reduction in energy costs of 0.55 $\$$/m 2 or $\$$2646/year for a large 4835 m 2 warehouse. Similarly, replacing the typical white roof coating with an RC coating could reduce the warehouse's energy consumption by up to 8.17 kWh/ m 2 of roof area, thus reducing energy costs by as much as 0.29 $\$$/m 2 or $\$$1386/year for a 4835 m 2 warehouse. In addition, applying RC paint to an unconditioned warehouse could reduce the building's ASHRAE Standard 55 indoor temperature exceedance by up to 1330 h/year compared to a black roof and up to 532 h/year compared to a white roof.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing Mass Timber Buildings: Novel Methods Improve Thermal Assessment and Material Use

For nearly a century, thermal demand calculations for buildings have relied on simplified models developed to match the technical constraints of their era. The first standards, introduced in Germany and Austria in 1929, established climate zones and material conductivity coefficients that, with only incremental updates, still underpin many current assessments. Yet, methods such as Hot box testing, originally designed for lightweight insulation, continue to be applied for mass timber buildings, overlooking thermodynamic characteristics confer real-world advantages. Recent research at Oak Ridge National Laboratory incorporates updated methodologies, aligned with ASHRAE Standard 55 (ASHRAE, 2023) accounting for factors such as thermal inertia, inner surface temperatures, emissivity, solar gains, and dynamic outdoor conditions. These factors better reflect observed heating and cooling loads and highlight opportunities for efficient use of materials in mass timber construction. This work provides a framework for designing comfortable, resilient, and resource-efficient buildings while aligning with performance expectations in energy codes.

Pickett, Robert [International Mass Timber Allianc↗

Energy burden aware and thermal resilience informed thermal energy storage system planning for disadvantaged communities

Disadvantaged communities often face a disproportionate energy burden because they need to allocate a higher percentage of their income to energy costs. More importantly, climate change-induced extreme weather events, such as heat waves and severe cold snaps, exacerbate these communities’ energy burdens. As a result, low- and medium-income communities are more likely to experience energy supply disruptions, increased health risks, and elevated energy bills because of inadequate thermal insulation and airtightness in their houses. Thermal energy storage (TES) systems, such as large-scale (community-level) geothermal energy storage and small-scale (building-level) phase change material (PCM)–based storage, have a great potential to improve building energy efficiency and to enhance thermal comfort, load shifting, and integration with renewable energy. The objective of this study is to optimally allocate building level PCM-based TES systems at the community level by considering energy equity and extreme weather effects. To this end, we developed an energy burden and thermal resilience–informed TES system planning framework, which includes three modules: (1) a community-level energy burden and thermal resilience assessment module, (2) building-level a TES system integration and assessment module, and (3) a community-level optimal planning module. Case studies were conducted on four disadvantaged communities in Montgomery and Shelby Counties in Tennessee with energy burdens >10% and with high percentages of people of color. The results indicate that this comprehensive planning framework can assist disadvantaged communities in reducing their energy burden and in bolstering their resilience against the adverse effects of climate change.

Shen, Zhenglai↗