Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Heat Flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Interfacial Solar Evaporation by a 3D Graphene Oxide Stalk for Highly Concentrated Brine Treatment

In this study, we demonstrate a 3-dimensional graphene oxide (3D GO) stalk that operates near the capillary wicking limit to achieve an evaporation flux of 34.7 kg m -2 h -1 under 1 sun conditions (1 kW/m 2 ). This flux represents nearly a 100 times enhancement over a conventional solar evaporation pond. Interfacial solar evaporation traditionally uses 2D evaporators to vaporize water using sunlight, but their low evaporative water flux limits their practical applicability for desalination. Some recent studies using 3D evaporators demonstrate potential for more efficient water transfer, but the flux improvement has been marginal because of a low evaporation area index (EAI), which is defined as the ratio of the total evaporative surface area to the projected ground area. By using a 3D GO stalk with an ultrahigh EAI of 70, we achieved nearly a 20-fold enhancement over a 2D GO evaporator. The 3D GO stalk also exhibited additional advantages including omnidirectional sunlight utilization, a high evaporation flux under dark conditions from more efficient utilization of ambient heating, a dramatic increase of the evaporation rate by introducing wind, and scaling resistance in evaporating brines with a salt content of up to 17.5 wt %. This performance makes the 3D GO stalk well suited for the development of a low-cost, reduced footprint technology for zero liquid discharge in brine management applications.

3D evaporator↗

Divertor detachment and heat exhaust mitigation control in KSTAR with tungsten divertor

KSTAR has recently undergone an upgrade to use a new tungsten divertor to run experiments in ITER-relevant scenarios. Even with a high melting point of tungsten, it is important to control the heat flux impinging on tungsten divertor targets to minimize sputtering and contamination of the core plasma. Heat flux on the divertor is often controlled by increasing the degree of detachment of scrape-off layer plasma from the target plates. In this work, we have demonstrated successful divertor detachment and heat exhaust dissipation control experiments using two different methods. The first method uses attachment fraction as a control variable which is estimated using ion saturation current measurements from embedded Langmuir probes in the divertor. The second method uses a novel machine-learning-based surrogate model of 2D UEDGE simulation database, DivControlNN. We demonstrated running inference operation of DivControlNN in realtime to estimate heat flux at the divertor and use it as the control variable in a feedback loop with impurity gas flow. We present interesting insights from these experiments including a systematic approach to tuning controllers and discuss future improvements in the control infrastructure and control variables for future burning plasma experiments.

KSTAR tungsten divertor operations↗

Ultra-High-Speed X-ray Tomography: Bridging the Gaps to See the Unknown

Rapid, time-varying, three-dimensional physics underpin numerous engineering challenges. Often, these physics occur within opaque environments, internal to a component, severely limiting applicable diagnostics. Development of novel diagnostics is necessary to understand and predict transient three-dimensional (3D) phenomena within opaque environments. This report highlights progress in four key areas leading to advancements in high-speed X-ray radiography and tomography. The first area is enabling MHz-rate imaging of energetics at the Advanced Photon Source at Argonne National Laboratory. The second is modeling a high-flux, rotating-anode X-ray source to understand the heat loads on the anode. The third effort was to develop a novel reconstruction algorithm that is validated by ground experimental tomography data and synthetic tomography data. The fourth is the development of a novel approach to two-color X-ray imaging.

42 ENGINEERING↗

Micro-tearing mode dominated electron heat transport in DIII-D H-mode pedestal

Abstract A new, comprehensive set of evidence reveals that Micro-Tearing Modes (MTMs) dominate pedestal electron heat transport in an H-mode experiment in the DIII-D tokamak. The experiment investigates the role of MTMs by scanning pedestal collisionality, a main drive of MTM instability, from 0.43 to 0.84 on the pedestal top. Broadband (150–800 kHz) magnetic and density fluctuations originating from the pedestal gradient region and highly consistent with MTMs are observed, with amplitude increasing during the scan. The higher magnetic fluctuation amplitude correlates with a lower pedestal electron temperature gradient, implying MTMs may regulate the pedestal electron heat transport. The collisionality scan results in profile and transport changes consistent with predicted transport capability of MTMs: (1) experimentally-determined electron heat diffusivity increases ∼40% at the location where the broadband density fluctuations peak; (2) ion heat diffusivity has less increase (<20%); and (3) a locally flattened region in the electron temperature pedestal is observed at high collisionality. A local, linear gyrokinetic simulation finds MTMs as the most unstable mode in the pedestal gradient region. In addition, local, nonlinear simulations suggest MTMs can dominate and drive experimentally-relevant, megawatt-level electron heat flux. This result establishes MTMs as an effective transport mechanism in the H-mode pedestal, in particular at high collisionality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design Overview of a High-Pressure Helium Flow Visualization Apparatus for Blanket Cooling Studies

Cooling of the fusion blanket first wall remains a significant challenge given the adverse conditions of heat and particle flux encountered near the plasma. Helium emerges as an attractive cooling candidate because of its chemical and neutronic inertness and separability from hydrogenic species (e.g. tritium). Because of the low thermal mass of helium, optimization of these coolant channels is warranted to provide high heat transfer performance at low pumping costs. Increasingly, computational fluid dynamics (CFD) simulations are employed to model and optimize these flow channels, and accompanying experimental data are needed to validate the predictions of these models. To provide the aforementioned experimental data, a high-pressure helium flow visualization upgrade has been designed for the Helium Flow Loop Experiment facility. This apparatus was built to American Society of Mechanical Engineers boiler and pressure vessel standards to withstand operating pressure of 4 MPa and mated to high-pressure glass windows. Seedless flow visualization is performed via high-speed background oriented schlieren (BOS), with image correlation used for time-resolved two-dimensional velocimetry at frequencies in excess of 60 kHz. Rectangular flow channel test articles are additively manufactured via laser powder bed fusion and installed into this visualization apparatus, with one-sided heating supplied by resistive heaters. In conclusion, the chosen test geometries were informed by prior CFD simulations, and the helium flow structures observed via BOS (detachment, recirculation, etc.) will be used for the validation of these accompanying models, in support of the design and optimization of blanket cooling channel configurations.

Helium flow↗

High-throughput computational framework for high-order anharmonic thermal transport in cubic and tetragonal crystals

Accurate first-principles prediction of lattice thermal conductivity (κL) remains challenging in identifying materials with extreme thermal behavior. While the harmonic approximation with three-phonon scattering (HA + 3ph) is now routine, reliable κL prediction often requires higher-order anharmonic effects, including self-consistent phonon renormalization, three- and four-phonon scattering, and off-diagonal heat flux (SCPH + 3, 4ph + OD). We present a state-of-the-art high-throughput workflow that unifies these effects and apply it to 773 cubic and tetragonal crystals spanning diverse chemistries and structures. From 562 dynamically stable compounds, we assess the hierarchical impacts of higher-order anharmonicity. For around 60% of materials, HA + 3ph predictions closely match those from SCPH + 3, 4ph + OD. SCPH generally increases κ L , by over 8 times in extreme cases, whereas four-phonon scattering universally suppresses κ L , sometimes to 15% of the HA + 3ph value. Off-diagonal contributions are negligible in high-κ L systems but can rival diagonal terms in highly anharmonic low-κ L compounds. We highlight four case studies, Rb 2 TlAlH 6 , Cu 3 VSe 4 , CuBr, and KTlCl 4 , that exhibit distinct extreme behaviors. This work delivers not only a robust workflow for high-fidelity κL dataset but also a quantitative framework to determine when higher-order effects are essential. The hierarchy of κ L results, from the HA + 3ph to SCPH + 3, 4ph + OD level, offers a scalable, interpretable route to discovering next-generation extreme thermal materials.

36 MATERIALS SCIENCE↗

Predicted Heat Flux Performance of Actively Cooled Tungsten-Armored Graphitic Foam Monoblocks

Tungsten (W)–armored graphitic foam monoblocks were developed for applications requiring high-Z plasma-facing material in long-pulse fusion experiments and ultimately deuterium-tritium fusion reactors. The monoblocks are an integrated material system combining the advantages of a chemical vapor deposited (CVD) W coating with a high-conductivity graphitic foam. The W is a high-melting-point, high-Z material with low tritium retention. The graphitic foam coupled to a swirl tube serves as a high-thermal-conductivity heat sink that cannot melt, although it can sublime at much higher temperatures than copper melts. Together, they comprise a robust plasma-facing component (PFC) weighing roughly 5% of an all-W component or 17% of a traditional W-coated copper heat sink.A single-channel mock-up consisting of four graphitic foam monoblocks equipped with a water-cooled swirl tube was fabricated for eventual testing in the 60-kW, EB-60, rastered electron beam at the Applied Research Laboratory of The Pennsylvania State University. Two monoblocks have a thin 50-μm-thick coating of pure W chemically vapor deposited over NbC and pure Nb interlayers. Two others have a 2-mm-thick pure W coating CVD on graphitic monoblocks using the same interlayers. The mock-up will be cooled with available 10 m/s, 0.7 MPa water with a 22°C inlet temperature and subjected to varying uniform heat loads up to 20 MW/m 2 . It is equipped with type-K thermocouples at various depths, and calibrated infrared thermography and spot pyrometry will be used to characterize the heated surface. Real-time water calorimetry will be used to ascertain the absorbed steady-state power and infer the heat flux during testing. Since testing cannot be done under prototypic divertor flow conditions, it is necessary to predict the thermal response of this novel PFC system and investigate the power sharing between radiation and convection at divertor heat flux levels and its inherent ability to avoid critical heat flux. Results are reported for predictions obtained from computational fluid dynamics models up to 30 MW/m 2 of steady-state uniform heat flux. Leading-edge heat loads of 30 MW/m 2 on a 2-mm-wide side strip were also investigated to ascertain if coating delamination is likely.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AmeriFlux US-GL1 Stannard Rock

This is the AmeriFlux version of the carbon flux data for the site US-GL1 Stannard Rock. Site Description - Stannard Rock is located 39 km from the nearest shore (Keweenaw Peninsula) in Lake Superior, 44 miles NNE of Marquette, Michigan, and 24 miles ESE of Manitou Island. The site is located on the historic Stannard Rock Lighthouse, which was completed in 1882. Eddy covariance instrumentation was installed in 2008 by a network of scientists from both US and Canada, eventually to be called the Great Lakes Evaporation Network (GLEN). The intent of GLEN has been to provide observations of over-lake meteorology and evaporation, improve forecasting of Great Lakes water levels, and support a wide variety of stakeholders, including the National Weather Service (NWS), Environment and Climate Change Canada, National Oceanic and Atmospheric Administration, U.S. Coast Guard, recreational boaters and commercial shipping, emergency management officials, and the Great Lakes research community. The eddy covariance station along with other ancillary meteorological instrumentation is located at an approximate elevation of 39.2 meters above mean lake water level. Meteorological data from the lighthouse are sent to the National Data Buoy Center, where they can be viewed in real-time at http://www.ndbc.noaa.gov/station_page.php?station=stdm4 Uncorrected half-hour fluxes were computed directly on the logger using a 30-minute block averaging period as high-frequency data were not available. The half hour flux measurements downloaded from the datalogger were post-processed with the following filters and corrections. Latent and sensible heat and carbon dioxide fluxes were corrected with 2-D coordinate rotation. Although the primary objective of data collection at Stannard Rock was to quantify the evaporative flux, additional preliminary measurements of the carbon dioxide concentration and flux from the LI-7500 are also included in this dataset but it is advised to use the carbon data with caution. Carbon data reported in this dataset includes turbulent fluxes of CO2 with no storage correction (FC, µmol m-2 s-1) and CO2 density in mole fraction of wet air (CO2), which was originally output on the datalogger as average CO2 density (mg m-2 s-1) and converted into µmol mol-1 using air temperature and pressure in post-processing. Webb, Pearman, and Leuning terms were applied to account for density fluctuations for water vapor and CO2. Sonic path length, high-frequency attenuation and sensor separation were accounted for according to Horst and Massman, and the oxygen absorption correction for the KH2O hygrometer was also applied. Latent and sensible heat fluxes were assumed to be unrealistic above an absolute value of 1000 W m-2 and were removed. Both carbon flux (FC) and carbon dioxide mole fraction in wet air (CO2) and were assumed to be unrealistic above 1000 µmol m-2 s-1 and 1000 µmol mol-1 respectively. Spikes in latent and sensible heat and carbon fluxes and densities (often due to periods of precipitation) were identified by computing the mean and standard deviation over a moving, overlapping window of 336 half-hours (7 days), similar to Shao et al., and were removed when the flux was more than 1.5 standard deviations from the moving window’s mean. While Vickers and Mahrt use a threshold of 3.5 standard deviations from the mean, a conservative value of 1.5 was chosen due to the noisy nature of over-lake data at this particular site. This process was repeated twice for latent and sensible heat, and carbon dioxide fluxes and densities and therefore it is possible that some real, realistic data was filtered out in this process. No detrending was performed. As per AmeriFlux standards, no friction velocity (USTAR, m s-1) filtering was performed.

Spence, Chris↗

AmeriFlux FLUXNET-1F US-GL1 Stannard Rock

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-GL1 Stannard Rock. This is the FLUXNET version of the carbon flux data for the site US-GL1 Stannard Rock produced by applying the standard ONEFlux (1F) software. Site Description - Stannard Rock is located 39 km from the nearest shore (Keweenaw Peninsula) in Lake Superior, 44 miles NNE of Marquette, Michigan, and 24 miles ESE of Manitou Island. The site is located on the historic Stannard Rock Lighthouse, which was completed in 1882. Eddy covariance instrumentation was installed in 2008 by a network of scientists from both US and Canada, eventually to be called the Great Lakes Evaporation Network (GLEN). The intent of GLEN has been to provide observations of over-lake meteorology and evaporation, improve forecasting of Great Lakes water levels, and support a wide variety of stakeholders, including the National Weather Service (NWS), Environment and Climate Change Canada, National Oceanic and Atmospheric Administration, U.S. Coast Guard, recreational boaters and commercial shipping, emergency management officials, and the Great Lakes research community. The eddy covariance station along with other ancillary meteorological instrumentation is located at an approximate elevation of 39.2 meters above mean lake water level. Meteorological data from the lighthouse are sent to the National Data Buoy Center, where they can be viewed in real-time at http://www.ndbc.noaa.gov/station_page.php?station=stdm4 Uncorrected half-hour fluxes were computed directly on the logger using a 30-minute block averaging period as high-frequency data were not available. The half hour flux measurements downloaded from the datalogger were post-processed with the following filters and corrections. Latent and sensible heat and carbon dioxide fluxes were corrected with 2-D coordinate rotation. Although the primary objective of data collection at Stannard Rock was to quantify the evaporative flux, additional preliminary measurements of the carbon dioxide concentration and flux from the LI-7500 are also included in this dataset but it is advised to use the carbon data with caution. Carbon data reported in this dataset includes turbulent fluxes of CO2 with no storage correction (FC, µmol m-2 s-1) and CO2 density in mole fraction of wet air (CO2), which was originally output on the datalogger as average CO2 density (mg m-2 s-1) and converted into µmol mol-1 using air temperature and pressure in post-processing. Webb, Pearman, and Leuning terms were applied to account for density fluctuations for water vapor and CO2. Sonic path length, high-frequency attenuation and sensor separation were accounted for according to Horst and Massman, and the oxygen absorption correction for the KH2O hygrometer was also applied. Latent and sensible heat fluxes were assumed to be unrealistic above an absolute value of 1000 W m-2 and were removed. Both carbon flux (FC) and carbon dioxide mole fraction in wet air (CO2) and were assumed to be unrealistic above 1000 µmol m-2 s-1 and 1000 µmol mol-1 respectively. Spikes in latent and sensible heat and carbon fluxes and densities (often due to periods of precipitation) were identified by computing the mean and standard deviation over a moving, overlapping window of 336 half-hours (7 days), similar to Shao et al., and were removed when the flux was more than 1.5 standard deviations from the moving window’s mean. While Vickers and Mahrt use a threshold of 3.5 standard deviations from the mean, a conservative value of 1.5 was chosen due to the noisy nature of over-lake data at this particular site. This process was repeated twice for latent and sensible heat, and carbon dioxide fluxes and densities and therefore it is possible that some real, realistic data was filtered out in this process. No detrending was performed. As per AmeriFlux standards, no friction velocity (USTAR, m s-1) filtering was performed.

Spence, Chris [Environment and Climate Change Cana↗

Infinite photovoltaic solar arrays: Considering flux of momentum and heat transfer

Large scale solar farms supply an increasing amount of the worlds electricity supply. However, high operation temperatures can strongly reduce efficiency and panel lifetime, negatively affecting the levelized cost of energy. In this work, the convective heat transfer coefficient for a utility-scale solar farm is studied with combined thermal and particle-image-velocimetry measurements in a scaled wind tunnel experiment. The measurements confirm the applicability of the scaled experimental setup to study large solar arrays. The velocity measurements indicate the complex flow structure within the solar array, governed by wakes directed upwards due to the orientation of the solar panels.

14 SOLAR ENERGY↗

Conceptual Design of High Field Central Solenoid for Fusion Nuclear Science Facility

Fusion Nuclear Science Facility (FNSF) is a critical fusion nuclear step in the US beyond ITER before proceeding to a larger and electricity producing fusion power plant. Although FNSF is a steady state machine to be operated at high duty cycle, a high field and high current density central solenoid magnet is needed for plasma startups. Due to space constraints in the FNSF in-board radial build, the magnetic field and coil current density required exceed conventional low temperature superconductor (LTS) performance limits and the design can only be achieved by high temperature superconductors (HTS). The design for the central solenoid, also called the ohmic heating (OH) magnet for FNSF shall meet the 100 Weber double flux swing requirement for plasma startups. Finally, the stresses at such a high field and high current density coil may require a bucked and wedged TF-OH design to accommodate space for coil winding support structures in in-board system radial build for high field FNSF operations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation of the SPARC plasma boundary with the UEDGE code

Here in this work, the UEDGE edge transport code is used to examine conditions in the SPARC divertor and edge plasma for various levels of carbon impurity and power from the core (P SOL ). A double-null magnetic configuration is simulated assuming up-down symmetry in geometry and physics. The anomalous heat and particle transport coefficients are tuned to match empirical predictions for SPARC's midplane density profiles, target plate heat flux profiles, and inner/outer divertor power sharing. Convective transport is included on the low-field side, while on the high-field side the transport is modeled as purely diffusive. Hydrogen neutrals are modeled as a fluid with inertial effects, and a carbon impurity is included using the fixed-fraction model. We find that detachment induced by impurity seeding could significantly reduce the heat flux to the divertor surfaces in the SPARC tokamak. At P SOL = 28 MW (the value predicted for SPARC's full-power H-mode scenario) cases with both divertor legs detached were obtained with a carbon impurity fraction between 0.3%–1.4%, far below Z eff limits for SPARC. When the plasma in the outer leg is detached, the peak heat flux density perpendicular to the target plate is below 1 MW m -2 , electron and ion temperatures are less than 1.5 eV, and momentum detachment is observed. However, the detachment state is found to be sensitive to the side-wall boundary conditions, the level of neutral pumping, and the target plate tilt. Finally, a broadly similar SOLPS simulation of SPARC is used to assess the appropriateness of the simpler impurity and neutral models used in UEDGE.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solar Heat for Industrial Processes: Integration with Chemical Reactors

The integration of solar thermal systems with chemical reactors has been proposed as part of a larger effort to develop and deploy solar heat for industrial processes (SHIP) technologies. A strong motivation for SHIP processes and technologies is the potential for high thermal efficiency coupled with low-cost thermal energy storage (TES) which can enable commercial deployment of such systems. While there are different ways to categorize SHIP technologies, one important such distinction is between directly irradiated systems and indirect off-sun process driven by a SHIP system. While directly irradiated systems can provide high thermal efficiencies and high fluxes, they usually require complex engineering solutions due to the need for redesigning the established processes and unit operations. In most cases, it is also more challenging to couple such a process to a TES system, losing some of the benefits of SHIP. On the other hand, using a SHIP system to drive an industrial process off-sun can allow better integration with existing process chains, easier TES capabilities, and potential for more applications fitting a specific SHIP technology. However, the integration of SHIP systems with the industrial processes is not fully explored in detail, especially in the case of high-temperature processes such as reforming, cracking, cement manufacturing, and iron/steelmaking. Many of these systems require heating fluxes of >50 kW/m^2, supplied via combustion of hydrocarbons in a fire box and benefitting from radiative heat transfer between the flue gases and the reaction zones. As such, using SHIP systems for such processes is more complex than providing the same thermal input in the form of a heat transfer medium (HTM) entering the reactor, kiln, or furnace. Moreover, in case convective heat transfer using SHIP is envisioned, for example using supercritical CO2 as the HTM from a particle receiver, the thermal integration might be more challenging than initially envisioned: lower heat transfer coefficients and limited approach temperature might require large flow rates, causing a mismatch between the process thermal requirements and the thermal capacity of the SHIP system. In addition, even if the heat exchange between SHIP and reactor is effective, there is still a cold leg HTM at the reaction temperature or slightly below it. Chemical plants usually include a set of heat exchangers, heat recovery steam generators, and even power generation units - in a tightly integrated design - to recover the flue gases which are eventually vented. With SHIP systems mostly operating on a closed HTM loop, bottoming the cold leg is crucial. In this talk, we will present different modeling results for a variety of syngas production reactions, using catalytic and chemical looping processes, and discuss some of the challenges and design considerations for off-sun chemical reactors using SHIP systems.

14 SOLAR ENERGY↗

A simple vacuum suitcase for enabling plasma facing component characterization in fusion devices

We have demonstrated a vacuum suitcase to transport samples in vacuo to a surface analysis station for characterization of tokamak plasma facing components (PFCs). This technique enables surface analysis at powerful, dedicated stations that are not encumbered by design constraints imposed on them by a tokamak. The vacuum suitcase is an alternative solution to characterizing PFCs using diagnostics that are designed and built around a tokamak. The vacuum suitcase, called the Sample Exposure Probe (SEP), features mobile ultra-high vacuum pumping. Active pumping under high vacuum enables sample transfer between the Lithium Tokamak eXperiment-β (LTX-β) and a high resolution X-ray Photoelectron Spectroscopy (XPS) system that is situated close by. A thermocouple inserted in the back of the sample head measures heat flux from the plasma during exposure, and together with a button heater, allows the sample to match the LTX-β PFCs in high temperature operations. As vacuum conditions are better during transfer and analysis than in the tokamak, less contamination is introduced to the samples. XPS scans on a dedicated analysis station enable peak identification due to higher resolution and signal to noise ratio. A similar probe could be implemented for other fusion devices. As a result, the SEP is the first vacuum suitcase implementation for fusion applications that incorporates active pumping.

47 OTHER INSTRUMENTATION↗

Modeling and Experimental Demonstration of Flux Spreading in Light Trapping Planar-Cavity Solar Enclosed Particle Receivers

This study experimentally validates and numerically models the flux-spreading effect in a light-trapping planar-cavity solar receiver) for particle-based concentrating solar power systems. The receiver's shallow cavity with vertical planar walls redistributes concentrated solar flux, reducing peak intensity and achieving uniform heat flux. On-sun tests at National Renewable Energy Laboratory's High-Flux Solar Furnace under flux up to 1500 kW/m2 measured cavity wall temperatures, which were compared with Monte Carlo ray-tracing (SolTrace) and computational numerical simulations. Three angular absorptance models were evaluated: constant absorptance, a Pyromark-based directional model, and a Fresnel-based Cr2O3 model. The Fresnel-derived model showed the best agreement with experiments, achieving high correlation (PC > 0.85), structural similarity (SSIM > 0.98), and signal-to-noise ratios (PSNR > 40 dB), with temperature prediction errors of 1-11%. Results confirm that flux spreading mitigates local overheating and validate the integrated modeling approach, supporting the solar receiver scalability for high-efficiency, high-temperature concentrating solar power applications.

14 SOLAR ENERGY↗

Phenomena Identification and Ranking Table (PIRT) for heat pipes

Heat pipes are advanced passive thermal management devices that utilize phase change and capillary action to achieve efficient heat transfer. However, due to the complexity of the phenomena coupled in heat pipes, including capillary, phase change, turbulence, and compressibility effects, there are high uncertainties in the predictability of their operational regimes and performance. This PIRT exercise, conducted as a collaborative effort involving the Department of Energy (DOE) Microreactor Program (MRP), the Nuclear Regulatory Commission (NRC), and university partners systematically identifies, reviews, and prioritizes critical phenomena affecting the operation of heat pipes based on their importance and knowledge levels. Additional analyses and discussion are provided for phenomena with high importance and low knowledge, such as wick de-wetting, critical heat flux, contact angles, and pressure dynamics. The discussions included the recognizing challenges and proposing future research directions for both modeling and simulation and experimental efforts. Additionally, the report addresses phenomena with medium importance and low knowledge that could impact heat pipe operation during non-normal or transient operation, including frozen startup, laminar to turbulent transition, geyser boiling, wick priming, underfilling conditions, surface roughness of the wick, NCGs trapped in the wick, and the timescales of startup and shutdown. In conclusion, this comprehensive evaluation serves as a valuable resource for guiding future research and development efforts, supporting the successful integration of heat pipes into critical applications such as nuclear reactors, and contributing to the advancement of heat pipe technologies in safety-critical industries.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Multi-X-point radiation and its dynamics in up/down asymmetry in plasma detachment regimes in Wendelstein 7-X

In Wendelstein 7-X (W7-X), stable plasma detachment in ECRH hydrogen plasmas is routinely achieved with the standard magnetic configuration, containing five magnetic islands in the scrape-off layer (SOL). Plasma detachment induced by intrinsic carbon impurities is characterized by a high radiation fraction (ƒ rad ) with significantly reduced divertor heat load and particle flux. In this work, we present the radiation dynamics during the detached plasma (DP) phase, such as the shift of radiation zones in radial and poloidal directions towards the X-points as ƒ rad increases (∼0.6–0.9), as well as the penetration of the radiation layer into the confinement region in the deep DP phase with ƒ rad approaching unity. In particular, a structure of multi-X-point radiation (multi-XPR) with an up/down asymmetry in the DP phase is highlighted, which is revealed by bolometer tomography and is further confirmed by video diagnostics. The multi-XPR structure forms helical 3D bands aligned with W7-X field periodicity. Field reversal experiments show that the brightest XPR displaces between the upper and lower SOL regions, suggesting the E× B drift effects. This paper presents the multi-XPR structure observed in the W7-X plasma in detail for the first time. A simplified model considering the influence of the poloidal E× B drift ( V d ) on the impurity flow in the SOL shows that the downstream drift toward the target or target shadow region ( V d < 0) decreases the impurity content, while the upstream drift toward the LCFS ( V d > 0) increases the impurity content. On this basis, the poloidal drift potentially leads to an up/down asymmetry of impurity density in the SOL despite the symmetry magnetic topology. The dynamics of the up/down asymmetry in the multi-XPR structure is also related to the magnitude V d /D (normalized to the impurity diffusivity), with an additional effect owing to the radial inward shift of the emission zone. These results provide new insights into impurity-induced detachment dynamics and provide a basis for improving 3D modeling of impurity transport, which typically does not consider drifts.

E × B drift↗

Phenomena Identification and Ranking Table (PIRT) for Heat Pipes

This Phenomena Identification and Ranking Table (PIRT) report provides an evaluation of key phenomena affecting the performance and operational regimes of heat pipes, particularly in the context of heat pipe microreactors (HPMRs). Heat pipes are advanced passive thermal management devices that utilize phase change and capillary action to achieve efficient heat transfer. However, due to the complexity of the phenomena coupled in the heat pipe, including phase change, turbulent transition, and compressibility effects, among others, there is high uncertainty in identifying and ranking the important phenomena affecting the operation of heat pipes and the current knowledge for their modeling and simulation and experimental measurements and instrumentation. This PIRT exercise, conducted as a collaborative effort involving the Department of Energy (DOE) Microreactor Program (MRP), the Nuclear Regulatory Commission (NRC), and university partners systematically identifies, reviews, and prioritizes critical phenomena affecting the operation of heat pipes based on their importance and knowledge levels. The report analyzes phenomena with high importance and low knowledge, such as wick de-wetting, critical heat flux, contact angles, and pressure dynamics, discussing challenges and future research directions for improving their modeling and simulation and experimental measurements. Additionally, the report addresses phenomena with low knowledge that could impact heat pipe operation during non-normal or transient operation, including frozen startup, laminar to turbulent transition, geysering, wick priming, underfilling conditions, surface roughness of the wick, NCGs trapped in the wick, and the timescales of startup and shutdown. This comprehensive evaluation serves as a valuable resource for guiding future research and development efforts, supporting the successful integration of heat pipes into critical applications such as nuclear reactors, and contributing to the advancement of heat pipe technologies in safety-critical industries.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗