Search NASA⌕ Search

SEARCH · Search NASA

Results for “High resolution data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers

Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5,000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and high purity germanium (HPGe) data, allowing direct comparison. Here, we present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ Synchrotron X‐ray Metrology Boosted by Automated Data Analysis for Real‐time Monitoring of Cathode Calcination

Abstract Synchrotron X‐ray‐based in situ metrology is advantageous for monitoring the synthesis of battery materials, offering high throughput, high spatial and temporal resolution, and chemical sensitivity. However, the rapid generation of massive data poses a challenge to on‐site, on‐the‐fly analysis needed for real‐time process monitoring. Here, a weighted lagged cross‐correlation (WLCC) similarity approach is presented for automated data analysis, which merges with in situ synchrotron X‐ray diffraction metrology to monitor the calcination process of the archetypal nickel‐based cathode, LiNiO 2 . The WLCC approach, incorporating variables that account for peak shifts and width changes associated with structural transformations, enables rapid extraction of phase progression within 10 seconds from tens of diffraction patterns. Details are captured, from initial precursors to intermediates and the final layered LiNiO 2 , providing information for agile on‐site adjustments during experiments and complementing post hoc diffraction analysis by offering insights into early‐stage phase nucleation and growth. Expanding this data‐powered platform paves the way for real time calcination process monitoring and control, which is pivotal to quality control in battery cathode manufacturing.

36 MATERIALS SCIENCE↗

A high-transparency, micro-patternable chip for X-ray diffraction analysis of microcrystals under native growth conditions

A highly X-ray-transparent, silicon nitride-based device has been designed and fabricated to harvest protein microcrystals for high-resolution X-ray diffraction data collection using microfocus beamlines and XFELs. Microcrystals present a significant impediment to the determination of macromolecular structures by X-ray diffraction methods. Although microfocus synchrotron beamlines and X-ray free-electron lasers (XFELs) can enable the collection of interpretable diffraction data from microcrystals, there is a need for efficient methods of harvesting small volumes (<2 µl) of microcrystals grown under common laboratory formats and delivering them to an X-ray beam source under native growth conditions. One approach that shows promise in overcoming the challenges intrinsic to microcrystal analysis is to pair so-called ‘fixed-target’ sample-delivery devices with microbeam-based X-ray diffraction methods. However, to record weak diffraction patterns it is necessary to fabricate devices from X-ray-transparent materials that minimize background scattering. Presented here is the design of a new micro-diffraction device consisting of three layers fabricated from silicon nitride, photoresist and polyimide film. The chip features low X-ray scattering and X-ray absorption properties, and uses a customizable blend of hydrophobic and hydrophilic surface patterns to help localize microcrystals to defined regions. Microcrystals in their native growth conditions can be loaded into the chips with a standard pipette, allowing data collection at room temperature. Diffraction data collected from hen egg-white lysozyme microcrystals (10–15 µm) loaded into the chips yielded a complete, high-resolution (<1.6 Å) data set sufficient to determine a high-quality structure by molecular replacement. The features of the chip allow the rapid and user-friendly analysis of microcrystals grown under virtually any laboratory format at microfocus synchrotron beamlines and XFELs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Giant Molecular Clouds and High-Mass Star Formation in the Milky Way

We are conducting an extensive investigation of high-mass (OB) star formation within the dense cores of giant molecular clouds (GMCS) throughout the first Galactic quadrant of the Milky Way using enhanced resolution Infrared Astronomical Satellite (IRAS) images in combination with high-resolution ground-based observations in millimeter wave molecular transitions and radio continuum. As part of this investigation several resolution enhancement algorithms are applied to the IRAS data, including the HIgh RESolution (HIRES) algorithm developed at the IRAS Processing and Analysis Center (IPAC), as well as others ("pixon" image reconstruction). In addition, as part of a related study, we have completed a large survey of the CO emission in the first Galactic quadrant using the 15-element array detector (QUARRY) with the Five College Radio Astronomy Observatory (FCRAO) 14 m antenna, which provides sampling at an angular resolution of 50", comparable to that attained in the reprocessed IRAS data. Both of these data sets are compared with a sample of ultra-compact (UC) H II regions taken from a high-resolution multi-wavelength (6 and 20 cm) radio survey of the Galactic plane using the NRAO Very Large Array (VLA). Selected regions are observed in 1.3 mm continuum, which has proven to be particularly sensitive to the dust column density. Extensive observations of molecular clouds at high resolution in CO, CS and HCN are combined with the reprocessed IRAS high-resolution images to give a more complete picture of the physical conditions and kinematics of high-mass star forming GMCS. Our goals are to study in detail the morphology, structure, and rate of high-mass star formation within GMCs throughout the Galactic disk from the inner edge of the molecular ring to the outer Galaxy.

Source record↗

Comparison and validation of the QuEChERSER mega-method for determination of per- and polyfluoroalkyl substances in foods by liquid chromatography with high-resolution and triple quadrupole mass spectrometry

Instances of food contamination with per- and polyfluoroalkyl substances (PFAS) continue to occur globally, but sample preparation and analytical methods are quite limited and often monitor for a small percentage of known PFAS. This study aimed to evaluate, validate, and compare performance of two instruments with the recently developed “quick, easy, cheap, effective, rugged, safe, efficient, and robust” (QuEChERSER) sample preparation mega-method – a method developed to monitor chemicals over a broad range of physicochemical properties. Initial evaluation of the QuEChERSER mega-method for determination of PFAS in food demonstrated recoveries, matrix interferences, and co-extractive removal comparable to (or better than) US Food and Drug Administration (FDA) and USDA Food Safety and Inspection Service (FSIS) methods. Subsequent validation of QuEChERSER in beef, catfish, chicken, pork, liquid eggs, and powdered eggs on a high-resolution mass spectrometer achieved acceptable recoveries (70–120%) and precision (RSDs ≤20%) for all 33 target analytes at the 1 and 5 ng g –1 levels and 67–88% of analytes at the 0.1 ng g –1 level, depending on the matrix. Additional validation was performed by tandem mass spectrometry on a triple quadrupole instrument. This approach provided no non-detects and better recoveries at the 0.1 ng g –1 level than the HRMS method but exhibited more variability at 1 and 5 ng g –1 spiking levels. Analysis of NIST SRMs 1946 and 1947 gave accuracies of 70–117%. Furthermore, these results demonstrate the capability of combining PFAS analysis with a mega-method previously validated for 350 analytes, while collecting non-target data for future retrospective analysis of emerging alternatives with a high-resolution mass spectrometry method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measuring a Precise Ultra-Lightweight Spaceflight Mirror on Earth: The Analysis of the SHARPI PM Mirror Figure Data during Mirror Processing at GSFC

The SHARPI (Solar High Angular Resolution Photometric Imager) primary mirror is a 5kg, 0.5m paraboloid, diffraction limited at FUV wavelengths when placed in a 0-G environment. The ULE sandwich honeycomb mirror and the attached mount pads were delivered by ITT (then Kodak) in 2003 to NASA s Goddard Space Flight Center (GSFC). At GSFC, we accepted, coated, mounted, and vibration tested this mirror in preparation for flight on the PICTURES (Planet Imaging Concept Testbed Using a Rocket Experiment) mission. At each step, the integrated analysis of interferometer data and FEA models was essential to quantify the 0-G mirror figure. This task required separating nanometer sized variations from hundreds of nanometers of gravity induced distortion. The ability to isolate such features allowed in-situ monitoring of mirror figure, diagnosis of perturbations, and remediation of process errors. In this paper, we describe the technical approach used to achieve these measurements and overcome the various difficulties maintaining UV diffraction-limited performance with this aggressively lightweighted mirror.

Antonille, Scott↗

Analysis of Information Content in High-Spectral Resolution Sounders using Subset Selection Analysis

In this paper, we summarize the results of the sensitivity analysis and data reduction carried out to determine the information content of AIRS and IASI channels. The analysis and data reduction was based on the use of subset selection techniques developed in the linear algebra and statistical community to study linear dependencies in high dimensional data sets. We applied the subset selection method to study dependency among channels by studying the dependency among their weighting functions. Also, we applied the technique to study the information provided by the different levels in which the atmosphere is discretized for retrievals and analysis. Results from the method correlate well with intuition in many respects and point out to possible modifications for band selection in sensor design and number and location of levels in the analysis process.

Velez-Reyes, Miguel↗

Cloud properties inferred from 8-12 micron data

A trispectral combination of observations at 8-, 11-, and 12-micron bands is suggested for detecting cloud and cloud properties in the infrared. Atmospheric ice and water vapor absorption peak in opposite halves of the window region so that positive 8-minus-11-micron brightness temperature differences indicate cloud, while near-zero or negative differences indicate clear regions. The absorption coefficient for water increases more between 11 and 12 microns than between 8 and 11 microns, while for ice, the reverse is true. Cloud phases is determined by a scatter diagram of 8-minus-11-micron versus 11-minus-12-micron brightness temperature differences; ice cloud shows a slope greater than 1 and water cloud less than 1. The trispectral brightness temperature method was tested upon high-resolution interferometer data resulting in clear-cloud and cloud-phase delineation. Simulations using differing 8-micron bandwidths revealed no significant degradation of cloud property detection. Thus, the 8-micron bandwidth for future satellites can be selected based on the requirements of other applications, such as surface characterization studies. Application of the technique to current polar-orbiting High-Resolution Infrared Sounder (HIRS)-Advanced Very High Resolution Radiometer (AVHRR) datasets is constrained by the nonuniformity of the cloud scenes sensed within the large HIRS field of view. Analysis of MAS (MODIS Airborne Simulator) high-spatial resolution (500 m) data with all three 8-, 11-, and 12-micron bands revealed sharp delineation of differing cloud and background scenes, from which a simple automated threshold technique was developed. Cloud phase, clear-sky, and qualitative differences in cloud emissivity and cloud height were identified on a case study segment from 24 November 1991, consistent with the scene. More rigorous techniques would allow further cloud parameter clarification. The opportunities for global cloud delineation with the Moderate-Resolution Imaging Spectrometer (MODIS) appear excellent. The spectral selection, the spatial resolution, and the global coverage are all well suited for significant advances.

Strabala, Kathleen I.↗

Onboard Data Analysis for the Planetary Instrument for X-Ray Lithography

Imaging spectrometers are invaluable instruments for robotic science exploration, enabling quantitative maps of physical and chemical properties at high spatial resolution. This is particularly valuable in remote missions to other planetary bodies like Mars. The PIXL instrument on the Mars 2020 rover will deploy an arm-mounted X-Ray fluorescence spectrometer to map chemical composition at sub-millimeter scales. Its high resolution places dramatic new demands on instrument placement accuracy and measurement time. We address these challenges using novel on board data analysis strategies inspired by FRC science autonomy research.

Thompson, David R.↗

Aquifer Monitoring Using Ambient Seismic Noise Recorded With Distributed Acoustic Sensing (DAS) Deployed on Dark Fiber

Abstract Groundwater is a critical resource for human activities worldwide, and a vital component of many natural ecosystems. However, the state and dynamics of water‐bearing aquifers remain uncertain, mostly due to the paucity of subsurface data at high spatial and temporal resolution. Here, we show that analysis of infrastructure‐generated ambient seismic noise acquired on distributed acoustic sensing (DAS) arrays has potential as a tool to track variations in seismic velocities (d v / v ) caused by groundwater level fluctuations. We analyze 5 months of ambient noise acquired along an unused, 23 km‐long telecommunication fiber‐optic cable in the Sacramento Valley, CA, a so‐called “dark fiber." Three array subsections, ∼6 km apart, are processed and the stretching technique is applied to retrieve daily d v / v beneath each location. Near the Sacramento river, d v / v variations in the order of 2%–3% correlate with precipitation events and fluctuations in river stage of ∼1.5 m. In contrast, regions away (2.5 km) from the river do not experience large d v / v variations. These observations reveal short‐scale spatial variability in aquifer dynamics captured by this approach. Dispersion analysis and surface wave inversion of noise gathers reveal that seismic velocity perturbations occur at depths of 10–30 m. Rock physics modeling confirms that observed d v / v are linked to pore pressure changes at these depths, caused by groundwater table fluctuations. Our results suggest that DAS combined with ambient noise interferometry provides a means of tracking aquifer dynamics at high spatial and temporal resolutions at local to regional scales, relevant for effective groundwater resource management.

58 GEOSCIENCES↗

PolyDODT: a macrocyclic elastomer with unusual properties

The effect of reaction conditions on the structure of poly(3,6-dioxa-1,8-octanedithiol) (polyDODT) made by Reversible Radical Recombination Polymerization (R3P) using triethylamine (TEA), H 2 O 2 and air was investigated. 800 MHz (1 and 2D) NMR was used to investigate the polymer structures. Sensitivity analysis provided direct evidence for high purity cyclic polyDODT up to M n ~ 100 000 g mol –1 . Here, comparative analysis by High Resolution Multidetector Size Exclusion Chromatography (SEC) using integrated data showed that the cycles had lower viscosity and were more compact (both for R g and R h ) than linear samples of similar molecular weight. However, differential data revealed unusual behavior. While lower molecular weight cyclic polymers eluted later and had lower intrinsic viscosity than their linear counterparts at the same molecular weight, at higher molecular weights the polymers showed strange behavior: both the diffusion coefficient measured by Quasielastic Light Scattering (QELS) and Mark–Houwink–Sakurada plots of intrinsic viscosity for linear and cyclic polyDODT were found to converge. R3P, an aqueous based “green” method is capable of producing polymers at the 10–100 g scale in the lab, which will allow more detailed studies of this new class of biodegradable elastomers so further experimentation can be performed to elucidate the reasons for the unusual findings.

36 MATERIALS SCIENCE↗

Plasma physics and related challenges of millimeter-wave-to-terahertz and high power microwave generation

Homeland security and military defense technology considerations have stimulated intense interest in mobile, high power sources of millimeter-wave (mmw) to terahertz (THz) regime electromagnetic radiation, from 0.1 to 10 THz. While vacuum electronic sources are a natural choice for high power, the challenges have yet to be completely met for applications including noninvasive sensing of concealed weapons and dangerous agents, high-data-rate communications, high resolution radar, next generation acceleration drivers, and analysis of fluids and condensed matter. The compact size requirements for many of these high frequency sources require miniscule, microfabricated slow wave circuits. This necessitates electron beams with tiny transverse dimensions and potentially very high current densities for adequate gain. Thus, an emerging family of microfabricated, vacuum electronic devices share many of the same plasma physics challenges that are currently confronting 'classic' high power microwave (HPM) generators including long-life bright electron beam sources, intense beam transport, parasitic mode excitation, energetic electron interaction with surfaces, and rf air breakdown at output windows. The contemporary plasma physics and other related issues of compact, high power mmw-to-THz sources are compared and contrasted to those of HPM generation, and future research challenges and opportunities are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Carbon-enhanced metal-poor star frequencies in the galaxy: corrections for the effect of evolutionary status on carbon abundances

We revisit the observed frequencies of carbon-enhanced metal-poor (CEMP) stars as a function of the metallicity in the Galaxy, using data from the literature with available high-resolution spectroscopy. Our analysis excludes stars exhibiting clear overabundances of neutron-capture elements and takes into account the expected depletion of surface carbon abundance that occurs due to CN processing on the upper red giant branch. This allows for the recovery of the initial carbon abundance of these stars, and thus for an accurate assessment of the frequencies of carbon-enhanced stars. The correction procedure we develop is based on stellar-evolution models and depends on the surface gravity, log g, of a given star. Our analysis indicates that for stars with [Fe/H] ≤–2.0, 20% exhibit [C/Fe] ≥+0.7. This fraction increases to 43% for [Fe/H] ≤–3.0 and 81% for [Fe/H] ≤–4.0, which is higher than have been previously inferred without taking the carbon abundance correction into account. These CEMP star frequencies provide important inputs for Galactic and stellar chemical evolution models, as they constrain the evolution of carbon at early times and the possible formation channels for the CEMP-no stars. We also have developed a public online tool with which carbon corrections using our procedure can be easily obtained.

79 ASTRONOMY AND ASTROPHYSICS↗

IMAGING ANALYSIS OF THE HARD X-RAY TELESCOPE ProtoEXIST2 AND NEW TECHNIQUES FOR HIGH-RESOLUTION CODED-APERTURE TELESCOPES

Wide-field (≳100 deg{sup 2}) hard X-ray coded-aperture telescopes with high angular resolution (≲2′) will enable a wide range of time domain astrophysics. For instance, transient sources such as gamma-ray bursts can be precisely localized without the assistance of secondary focusing X-ray telescopes to enable rapid followup studies. On the other hand, high angular resolution in coded-aperture imaging introduces a new challenge in handling the systematic uncertainty: the average photon count per pixel is often too small to establish a proper background pattern or model the systematic uncertainty in a timescale where the model remains invariant. We introduce two new techniques to improve detection sensitivity, which are designed for, but not limited to, a high-resolution coded-aperture system: a self-background modeling scheme which utilizes continuous scan or dithering operations, and a Poisson-statistics based probabilistic approach to evaluate the significance of source detection without subtraction in handling the background. We illustrate these new imaging analysis techniques in high resolution coded-aperture telescope using the data acquired by the wide-field hard X-ray telescope ProtoEXIST2 during a high-altitude balloon flight in fall 2012. We review the imaging sensitivity of ProtoEXIST2 during the flight, and demonstrate the performance of the new techniques using our balloon flight data in comparison with a simulated ideal Poisson background.

79 ASTRONOMY AND ASTROPHYSICS↗

The analysis of ensembles of moderately saturated interstellar lines

It is shown that the combined equivalent widths for a large population of Gaussian-like interstellar line components, each with different central optical depths tau(0) and velocity dispersions b, exhibit a curve of growth (COG) which closely mimics that of a single, pure Gaussian distribution in velocity. Two parametric distributions functions for the line populations are considered: a bivariate Gaussian for tau(0) and b and a power law distribution for tau(0) combined with a Gaussian dispersion for b. First, COGs for populations having an extremely large number of nonoverlapping components are derived, and the implications are shown by focusing on the doublet-ratio analysis for a pair of lines whose f-values differ by a factor of two. The consequences of having, instead of an almost infinite number of lines, a relatively small collection of components added together for each member of a doublet are examined. The theory of how the equivalent widths grow for populations of overlapping Gaussian profiles is developed. Examples of the composite COG analysis applied to existing collections of high-resolution interstellar line data are presented.

Jenkins, E. B.↗

Scalable Adaptive Graphics Environment (SAGE) Software for the Visualization of Large Data Sets on a Video Wall

The use of collaborative scientific visualization systems for the analysis, visualization, and sharing of "big data" available from new high resolution remote sensing satellite sensors or four‐dimensional numerical model simulations is propelling the wider adoption of ultra‐resolution tiled display walls interconnected by high speed networks. These systems require a globally connected and well‐integrated operating environment that provides persistent visualization and collaboration services. This abstract and subsequent presentation describes a new collaborative visualization system installed for NASA's Shortterm Prediction Research and Transition (SPoRT) program at Marshall Space Flight Center and its use for Earth science applications. The system consists of a 3 x 4 array of 1920 x 1080 pixel thin bezel video monitors mounted on a wall in a scientific collaboration lab. The monitors are physically and virtually integrated into a 14' x 7' for video display. The display of scientific data on the video wall is controlled by a single Alienware Aurora PC with a 2nd Generation Intel Core 4.1 GHz processor, 32 GB memory, and an AMD Fire Pro W600 video card with 6 mini display port connections. Six mini display‐to‐dual DVI cables are used to connect the 12 individual video monitors. The open source Scalable Adaptive Graphics Environment (SAGE) windowing and media control framework, running on top of the Ubuntu 12 Linux operating system, allows several users to simultaneously control the display and storage of high resolution still and moving graphics in a variety of formats, on tiled display walls of any size. The Ubuntu operating system supports the open source Scalable Adaptive Graphics Environment (SAGE) software which provides a common environment, or framework, enabling its users to access, display and share a variety of data‐intensive information. This information can be digital‐cinema animations, high‐resolution images, high‐definition video‐teleconferences, presentation slides, documents, spreadsheets or laptop screens. SAGE is cross‐platform, community‐driven, open‐source visualization and collaboration middleware that utilizes shared national and international cyberinfrastructure for the advancement of scientific research and education.

Jedlovec, Gary↗

Imaging Analysis of the Hard X-Ray Telescope ProtoEXIST2 and New Techniques for High-Resolution Coded-Aperture Telescopes

Wide-field (greater than or approximately equal to 100 degrees squared) hard X-ray coded-aperture telescopes with high angular resolution (greater than or approximately equal to 2 minutes) will enable a wide range of time domain astrophysics. For instance, transient sources such as gamma-ray bursts can be precisely localized without the assistance of secondary focusing X-ray telescopes to enable rapid followup studies. On the other hand, high angular resolution in coded-aperture imaging introduces a new challenge in handling the systematic uncertainty: the average photon count per pixel is often too small to establish a proper background pattern or model the systematic uncertainty in a timescale where the model remains invariant. We introduce two new techniques to improve detection sensitivity, which are designed for, but not limited to, a high-resolution coded-aperture system: a self-background modeling scheme which utilizes continuous scan or dithering operations, and a Poisson-statistics based probabilistic approach to evaluate the significance of source detection without subtraction in handling the background. We illustrate these new imaging analysis techniques in high resolution coded-aperture telescope using the data acquired by the wide-field hard X-ray telescope ProtoEXIST2 during a high-altitude balloon flight in fall 2012. We review the imaging sensitivity of ProtoEXIST2 during the flight, and demonstrate the performance of the new techniques using our balloon flight data in comparison with a simulated ideal Poisson background.

balloons - instrumentation: detectors - techniques↗