Search NASA⌕ Search

SEARCH · Search NASA

Results for “High resolution data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Fast In Situ Airborne Measurement of Ammonia Using a Mid-Infrared Off-Axis ICOS Spectrometer

A new ammonia (NH 3 ) analyzer was developed based on off-axis integrated cavity output spectroscopy. Its feasibility was demonstrated by making tropospheric measurements in flights aboard the Department of Energy Gulfstream-1 aircraft. The ammonia analyzer consists of an optical cell, quantum-cascade laser, gas sampling system, control and data acquisition electronics, and analysis software. The NH 3 mixing ratio is determined from high-resolution absorption spectra obtained by tuning the laser wavelength over the NH 3 fundamental vibration band near 9.67 μm. Excellent linearity is obtained over a wide dynamic range (0–101 ppb v ) with a response rate (1/e) of 2 Hz and a precision of ±90 ppt v (1σ in 1 s). Two research flights were conducted over the Yakima Valley in Washington State. In the first flight, the ammonia analyzer was used to identify signatures of livestock from local dairy farms with high vertical and spatial resolution under low wind and calm atmospheric conditions. In the second flight, the analyzer captured livestock emission signals under windy conditions. Finally, our results demonstrate that this new ammonia spectrometer is capable of providing fast, precise, and accurate in situ observations of ammonia aboard airborne platforms to advance our understanding of atmospheric compositions and aerosol formation.

airborne↗

Quantification Of Cesium In Negative Hydrogen Ion Sources By Laser Absorption Spectroscopy

The use of cesium in negative hydrogen ion sources and the resulting cesium dynamics caused by the evaporation and redistribution in the vacuum and plasma phase makes a reliable and on-line monitoring of the cesium amount in the source highly desirable. For that purpose, a robust and compact laser absorption setup suitable for the ion source environment has been developed utilizing the Cs D{sub 2} resonance line at 852.1 nm. First measurements are taken in a small laboratory plasma chamber with cesium evaporation. A detection limit of {approx_equal}5x10{sup 13} m{sup -3} at a typical path length of 15 cm has been obtained with a dynamic range of more than three orders of magnitude, limited by line saturation at high densities. For on-line monitoring an automatic data analysis is established achieving a temporal resolution of 100 ms. The setup has then been applied to the ITER prototype ion sources developed at IPP. It is been shown that the method is well suited for routine measurements revealing a new insight into the cesium dynamics during source operation and cesium conditioning.

43 PARTICLE ACCELERATORS↗

Process monitoring of additive manufacturing by using optical tomography

Parts fabricated by means of additive manufacturing are usually of complex shape and owing to the fabrication procedure by using selective laser melting (SLM), potential defects and inaccuracies are often very small in lateral size. Therefore, an adequate quality inspection of such parts is rather challenging, while non-destructive-techniques (NDT) are difficult to realize, but considerable efforts are necessary in order to ensure the quality of SLM-parts especially used for aerospace components. Thus, MTU Aero Engines is currently focusing on the development of an Online Process Control system which monitors and documents the complete welding process during the SLM fabrication procedure. A high-resolution camera system is used to obtain images, from which tomographic data for a 3dim analysis of SLM-parts are processed. From the analysis, structural irregularities and structural disorder resulting from any possible erroneous melting process become visible and may be allocated anywhere within the 3dim structure. Results of our optical tomography (OT) method as obtained on real defects are presented.

42 ENGINEERING↗

LACK OF INTERACTION BETWEEN THE DUST GRAINS AND THE ANOMALOUS RADIO JET IN THE NEARBY SPIRAL GALAXY NGC 4258

We obtained Spitzer/IRAC 3.6-8 {mu}m images of the nearby spiral galaxy NGC 4258 to study possible interactions between dust and the radio jet. In our analysis, we also included high-resolution radio continuum, H{alpha}, CO, and X-ray data. Our data reveal that the 8 {mu}m emission, believed to originate largely from polycyclic aromatic hydrocarbon molecules and hot dust, is an excellent tracer of the normal spiral structure in NGC 4258, and hence it originates from the galactic plane. We investigated the possibility of dust destruction by the radio jet by calculating correlation coefficients between the 8 {mu}m and radio continuum emissions along the jet in two independent ways, namely, (1) from wavelet-transformed maps of the original images at different spatial scales and (2) from one-dimensional intensity cuts perpendicular to the projected path of the radio jet on the sky. No definitive sign of a correlation (or anticorrelation) was detected on relevant spatial scales with either approach, implying that any dust destruction must take place at spatial scales that are not resolved by our observations.

79 ASTRONOMY AND ASTROPHYSICS↗

MULTIWAVELENGTH PHOTOMETRY IN THE GLOBULAR CLUSTER M2

We present a multiwavelength photometric analysis of the globular cluster M2. The data set has been obtained by combining high-resolution (Hubble Space Telescope/WFPC2 and ACS) and wide-field (Galaxy Evolution Explorer) space observations and ground-based (MEGACAM-CFHT, EMMI-NTT) images. The photometric sample covers the entire cluster extension from the very central regions up to the tidal radius and beyond. It allows an accurate determination of the cluster center of gravity and other structural parameters derived from the star count density profile. Moreover, we study the Blue Straggler Star (BSS) population and its radial distribution. A total of 123 BSSs have been selected, and their radial distribution has been found to be bimodal (highly peaked in the center, decreasing at intermediate radii, and rising outward), as already found in a number of other clusters. The radial position of the minimum of the BSS distribution is consistent with the radius of avoidance caused by the dynamical friction of massive (1.2 M {sub sun}) objects over the cluster age. We also searched for gradients in the red giant branch (RGB) and the asymptotic giant branch (AGB) populations. At the 2{sigma} level, we found an overabundance of AGB stars within the core radius and confirmed the result of Sohn et al. that the central region of M2 is bluer than the outer part. We show that the latter is due to a deficit of very luminous RGB stars in the central region.

79 ASTRONOMY AND ASTROPHYSICS↗

HUBBLE SPACE TELESCOPE ASTROMETRY OF TRANS-NEPTUNIAN OBJECTS

We present 1428 individual astrometric measurements of 256 trans-Neptunian objects made with Hubble Space Telescope (HST). The observations were collected over three years with two instruments, the Wide Field Planetary Camera 2 and the Advanced Camera for Surveys High Resolution Camera, as part of four HST programs. We briefly describe the data and our analysis procedures. The submission of these measurements to the Minor Planet Center increased the individual arc length of objects by 1.83 days to 8.11 years. Of the 256 total objects, 62 (24.2%) had arc length increases of {>=}3 years. The arc length for 60 objects (23.4%) was increased by a factor of 2 or greater.

79 ASTRONOMY AND ASTROPHYSICS↗

Response to high-energy photons of PTW31014 PinPoint ion chamber with a central aluminum electrode

Since its introduction the PinPoint (PTW-Freiburg) micro-ionization chamber has been proposed for relative dosimetry (output factors, depth dose curves, and beam profiles) as well as for determination of absolute dose of small high-energy photon beams. This paper investigates the dosimetric performance of a new design (type 31014) of the PinPoint ion chamber with a central aluminum electrode. The study included characterization of inherent and radiation-induced leakage, ion collection efficiency and polarity effect, relative response of the chamber, measurement of beam profiles, and depth dose curves. The 6 and 15 MV photon beams of a Varian 2100 C/D were considered. At the nominal operating voltage of 400 V the PinPoint type 31014 chamber was found to present a strong field size dependence of the polarity correction factor and an excess of the collected charge, which can lead to an underestimation of the collection efficiency if determined with the conventional ''two-voltage'' method. In comparison to the original PinPoint design (type 31006) the authors found for type 31014 chamber no overresponse to large-area fields if polarity correction is applied. If no correction is taken into consideration, the authors found the chamber's output to be inaccurate for large-area fields (0.5% accuracy limited up to the 12x12 and 20x20 cm{sup 2} field for the 6 and 15 MV beams, respectively), which is a direct consequence of the stem and polarity effects due to the chamber's very small sensitive volume (0.015 cc) and cable irradiation. Beam profiles and depth dose curves measured with type 31014 PinPoint chamber for small and medium size fields were compared to data measured with a 0.125 cc ion chamber and with high-resolution Kodak EDR2 films. Analysis of the penumbra (80%-20% distance) showed that the spatial resolution of type 31014 PinPoint ion chamber approaches (penumbra broadening {<=}0.6 mm) EDR2 film results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Workshop to Identify Opportunities in Biological and Environmental Research Uniquely Enabled by the APS Upgrade

The development of synchrotron-based x-ray science has enabled tremendous scientific advances, driven both by discoveries of new fundamental ways to derive insight from the interaction of x-rays with matter and by the evolution of x-ray light sources themselves. Over the last 20-plus years, the U.S. Department of Energy’s (DOE’s) Advanced Photon Source (APS) at Argonne has yielded a multitude of transformational insights into science questions across numerous areas relevant to the biological, geological, geochemical, biogeochemical, and environmental sciences. Recent developments in accelerator technology, particularly the multi-bend achromat lattice, have led to plans to dramatically upgrade the APS, allowing an upgraded APS to offer orders-of-magnitude improvements in key parameters such as coherence and brightness, while retaining high-energy capabilities. These enhanced parameters are directly relevant to almost all hard x-ray imaging, scattering, and spectroscopy experiments (Eriksson et al., 2014). The APS Upgrade Project exceeds the capabilities of today’s synchrotrons by 2 to 3 orders of magnitude in brightness and coherent flux in the hard x-ray range, enabling a transformational range of new probes for the structure, properties, and functionality of matter. With vastly improved coherent flux, nearly all techniques can become microscopies. For example, frontiers inaccessible today will be opened by x-ray instruments that provide three-dimensional (3-D) real-space resolution down to nanometers across, up to millimeters of field of view, providing the ability to follow in real time relevant processes and trace element sensitivity down to a few atoms. In addition to the unprecedented spatial resolution across a large field of view, and with appropriate time resolution, the ability for high-throughput, four-dimension/five-dimension data collection enables unprecedented statistical analysis of complex biological and environmental systems in changing environments.

54 ENVIRONMENTAL SCIENCES↗

Mesh-Sequenced Realizations for Evaluation of Subgrid-Scale Models for Turbulent Combustion

This paper develops a new approach for analysis of subgrid closures for turbulent combustion as modeled using direct quadrature (finite-rate chemistry) techniques. The approach, termed multiresolution analysis through mesh-sequenced realizations (MRA-MSR), conducts simultaneous, constrained large-eddy simulations on a set of hierarchically coarsened meshes. Furthermore, the availability of underlying fine-mesh (subgrid) data corresponding to coarse-mesh locations allows a clearer assessment of the effects of unresolved fluctuations on apparent reactivity. A key to MRA-MSR is the correlation of eddy structures at coarser mesh levels, which is facilitated by the transfer of filtered fine-mesh velocity information. A seven-mesh MRA-MSR hierarchy using three resolution levels is applied to one of the Sydney bluff-body stabilized methane–hydrogen flames. Analysis of the simultaneously evolved data at different resolution levels reveals several interesting trends. First, at high Damköhler numbers, there is clear evidence of attenuation of apparent reactivity due to the effects of unresolved fluctuations. Secondly, single-point, single-time filtered density functions of a normalized subgrid Damköhler number show a characteristic beta probability density function (PDF) form and display evidence of scale similarity. Interrogation of the MRA-MSR database also shows that the recently-proposed least-squares minimization (LSM) turbulence–chemistry interaction model can account for the observed diminishment in reactivity at high Damköhler numbers but cannot reduce scatter significantly. A new form of the LSM model, which makes use of the normalized subgrid Damköhler number beta PDF distribution, performs slightly better than the original model, illustrating the potential of MRA-MSR both in assessing existing closure concepts and in developing new ones.

42 ENGINEERING↗

Variability and Diversity Load Model Tool [SWR-20-03]

The motivation for the development of this tool and the underlying algorithms and methods was to enable the development of high-temporal resolution, realistic time-series data for quasi-static time-series (QSTS) analysis of distribution systems. Often, aggregated load profile data for a distribution circuit is available (e.g. feeder loading data collected via SCADA at the utility substation) and, while this data is typically accurate it masks the considerable variability of the 100’s or 1000’s of individual loads connected on the circuit. This tool was developed to model both the increased variability expected for these individual loads (e.g. the load of a single distribution transformer connected to 8-12 houses) and the expected diversity between loads on the circuit. It is important to note that the difference in variability and diversity, in the context of this tool, is that variability modeling only adds representative variability due to disaggregated load characteristics (e.g. the presence in the load profile of loads turning off and on like an air conditioner/oven) while the average energy profile remains the same as the user supplied power profile. Diversity modeling generates multiple individual load profiles which, in aggregate, sum to the user supplied power profile. Diversity is effectively variability in the energy usage over longer periods of time than seen in the variability model. Put another way, variability modeling supplies the expected variability due to the operation of various end-use loads and diversity modeling supplies the usage differences due to human behavior, schedules, etc. This load modeling tool was developed for use in generating data for distribution systems. Modeling is summarized by two major functions: 1) taking low resolution load profiles and adding intra-seconds variability onto the profiles, and 2) taking a user supplied load profile and distribution factors and adding both diversity and variability to the user supplied profile.

Zhu, Xiangqi↗

High-level expression, purification, crystallization and preliminary X-ray crystallographic studies of the receptor-binding domain of botulinum neurotoxin serotype D

Botulinum neurotoxins (BoNTs) are highly toxic proteins for humans and animals that are responsible for the deadly neuroparalytic disease botulism. Here, details of the expression and purification of the receptor-binding domain (HCR) of BoNT/D in Escherichia coli are presented. Using a codon-optimized cDNA, BoNT/D{_}HCR was expressed at a high level (150-200 mg per litre of culture) in the soluble fraction. Following a three-step purification protocol, very pure (>98%) BoNT/D{_}HCR was obtained. The recombinant BoNT/D{_}HCR was crystallized and the crystals diffracted to 1.65 {angstrom} resolution. The crystals belonged to space group P2{sub 1}2{sub 1}2{sub 1}, with unit-cell parameters a = 60.8, b = 89.7, c = 93.9 {angstrom}. Preliminary crystallographic data analysis revealed the presence of one molecule in the asymmetric unit.

59 BASIC BIOLOGICAL SCIENCES↗

SIEMENS ADVANCED QUANTRA FTICR MASS SPECTROMETER FOR ULTRA HIGH RESOLUTION AT LOW MASS

The Siemens Advanced Quantra Fourier Transform Ion Cyclotron Resonance (FTICR) mass spectrometer was evaluated as an alternative instrument to large double focusing mass spectrometers for gas analysis. High resolution mass spectrometers capable of resolving the common mass isomers of the hydrogen isotopes are used to provide data for accurate loading of reservoirs and to monitor separation of tritium, deuterium, and helium. Conventional double focusing magnetic sector instruments have a resolution that is limited to about 5000. The Siemens FTICR instrument achieves resolution beyond 400,000 and could possibly resolve the tritium ion from the helium-3 ion, which differ by the weight of an electron, 0.00549 amu. Working with Y-12 and LANL, SRNL requested Siemens to modify their commercial Quantra system for low mass analysis. To achieve the required performance, Siemens had to increase the available waveform operating frequency from 5 MHz to 40 MHz and completely redesign the control electronics and software. However, they were able to use the previous ion trap, magnet, passive pump, and piezo-electric pulsed inlet valve design. NNSA invested $1M in this project and acquired four systems, two for Y-12 and one each for SRNL and LANL. Siemens claimed a $10M investment in the Quantra systems. The new Siemens Advanced Quantra demonstrated phenomenal resolution in the low mass range. Resolution greater than 400,000 was achieved for mass 2. The new spectrometer had a useful working mass range to 500 Daltons. However, experiments found that a continuous single scan from low mass to high was not possible. Two useful working ranges were established covering masses 1 to 6 and masses 12 to 500 for our studies. A compromise performance condition enabled masses 1 to 45 to be surveyed. The instrument was found to have a dynamic range of about three orders of magnitude and quantitative analysis is expected to be limited to around 5 percent without using complex fitting algorithms. Analysis of low concentration ions, at the ppm level, required a separate analysis using ion ejection techniques. Chemical ionization due to the formation of the MH{sup +} ion or MD{sup +} increased the complexity of the spectra compared to magnetic sector mass spectra and formation of the protonated or deuterated complex was a dynamic function of the trap ion concentration. This made quantitative measurement more of a challenge. However, the resolution of the instrument was far superior to any other mass spectrometry technique that has been applied to the analysis of the hydrogen isotopes. The piezo-electric picoliter injection device offers a new way of submitting small quantities of atmospheric pressure sample gas for analysis. The new software had many improvements over the previous version but significant flaws in the beta codes remain that make the prototype units less than ideal. The instrument is a promising new technology that experience will likely improve. Unfortunately, Siemens has concluded that the technology will not be a commercial success and has decided to stop producing this product.

74 ATOMIC AND MOLECULAR PHYSICS↗

Quantifying element incorporation in multispecies biofilms using nanoscale secondary ion mass spectrometry image analysis

Elucidating nutrient exchange in microbial communities is an important step in understanding the relationships between microbial systems and global biogeochemical cycles, but these communities are complex and the interspecies interactions that occur within them are not well understood. Phototrophic consortia are useful and relevant experimental systems to investigate such interactions as they are not only prevalent in the environment, but some are cultivable in vitro and amenable to controlled scientific experimentation. Nanoscale secondary ion mass spectrometry (NanoSIMS) is a powerful, high spatial resolution tool capable of visualizing the metabolic activities of single cells within a biofilm, but quantitative analysis of the resulting data has typically been a manual process, resulting in a task that is both laborious and susceptible to human error. In this work, the authors describe the creation and application of a semiautomated image-processing pipeline that can analyze NanoSIMS-generated data, applied to phototrophic biofilms as an example. The tool employs an image analysis process, which includes both elemental and morphological segmentation, producing a final segmented image that allows for discrimination between autotrophic and heterotrophic biomass, the detection of individual cyanobacterial filaments and heterotrophic cells, the quantification of isotopic incorporation of individual heterotrophic cells, and calculation of relevant population statistics. The authors demonstrate the functionality of the tool by using it to analyze the uptake of 15 N provided as either nitrate or ammonium through the unicyanobacterial consortium UCC-O and imaged via NanoSIMS. The authors found that the degree of 15N incorporation by individual cells was highly variable when labeled with 15 NH 4 + , but much more even when biofilms were labeled with 15 NO 3 – . In the 15 NH 4 + -amended biofilms, the heterotrophic distribution of 15 N incorporation was highly skewed, with a large population showing moderate 15 N incorporation and a small number of organisms displaying very high 15 N uptake. The results showed that analysis of NanoSIMS data can be performed in a way that allows for quantitation of the elemental uptake of individual cells, a technique necessary for advancing research into the metabolic networks that exist within biofilms with statistical analyses that are supported by automated, user-friendly processes.

59 BASIC BIOLOGICAL SCIENCES↗

TU-D-207B-05: Intra-Tumor Partitioning and Texture Analysis of DCE-MRI Identifies Relevant Tumor Subregions to Predict Early Pathological Response of Breast Cancer to Neoadjuvant Chemotherapy

Purpose: To predict early pathological response of breast cancer to neoadjuvant chemotherapy (NAC) based on quantitative, multi-region analysis of dynamic contrast enhancement magnetic resonance imaging (DCE-MRI). Methods: In this institution review board-approved study, 35 patients diagnosed with stage II/III breast cancer were retrospectively investigated using DCE-MR images acquired before and after the first cycle of NAC. First, principal component analysis (PCA) was used to reduce the dimensionality of the DCE-MRI data with a high-temporal resolution. We then partitioned the whole tumor into multiple subregions using k-means clustering based on the PCA-defined eigenmaps. Within each tumor subregion, we extracted four quantitative Haralick texture features based on the gray-level co-occurrence matrix (GLCM). The change in texture features in each tumor subregion between pre- and during-NAC was used to predict pathological complete response after NAC. Results: Three tumor subregions were identified through clustering, each with distinct enhancement characteristics. In univariate analysis, all imaging predictors except one extracted from the tumor subregion associated with fast wash-out were statistically significant (p< 0.05) after correcting for multiple testing, with area under the ROC curve or AUCs between 0.75 and 0.80. In multivariate analysis, the proposed imaging predictors achieved an AUC of 0.79 (p = 0.002) in leave-one-out cross validation. This improved upon conventional imaging predictors such as tumor volume (AUC=0.53) and texture features based on whole-tumor analysis (AUC=0.65). Conclusion: The heterogeneity of the tumor subregion associated with fast wash-out on DCE-MRI predicted early pathological response to neoadjuvant chemotherapy in breast cancer.

60 APPLIED LIFE SCIENCES↗

Reliable and Repeatable Characterization of Optical Streak Cameras

Optical streak cameras are used as primary diagnostics for a wide range of physics and laser experiments at facilities such as the National Ignition Facility (NIF). To meet the strict accuracy requirements needed for these experiments, the systematic nonlinearities of the streak cameras (attributed to nonlinearities in the optical and electrical components that make up the streak camera system) must be characterized. In some cases the characterization information is used as a guide to help determine how experiment data should be taken. In other cases, the characterization data are applied to the raw data images to correct for the nonlinearities. In order to characterize an optical streak camera, a specific set of data is collected, where the response to defined inputs are recorded. A set of analysis software routines has been developed to extract information such as spatial resolution, dynamic range, and temporal resolution from this data set. The routines are highly automated, requiring very little user input and thus provide very reliable and repeatable results that are not subject to interpretation. An emphasis on quality control has been placed on these routines due to the high importance of the camera characterization information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

COMPREHENSIVE ANALYSIS OF PREBIOTIC PROPENAL UP TO 660 GHz

Since interstellar detection of propenal is only based on two rotational transitions in the centimeter wave region, its high resolution rotational spectrum has been measured up to 660 GHz and fully characterized by assignment of more than 12,000 transitions to provide direct laboratory data to the astronomical community. Spectral assignments and analysis include transitions from the ground state of the trans and cis isomers, three trans-{sup 13}C isotopologues, and ten excited vibrational states of the trans form. Combining new millimeter and submillimeter data with those from the far-infrared region has yielded the most precise set of spectroscopic constants of trans-propenal obtained to date. Newly determined rotational constants, centrifugal distortion constants, vibrational energies, and Coriolis and Fermi interaction constants are given with high accuracy and were used to predict transition frequencies and intensities over a wide frequency range. Results of this work should facilitate astronomers further observation of propenal in the interstellar medium.

74 ATOMIC AND MOLECULAR PHYSICS↗

SICK: THE SPECTROSCOPIC INFERENCE CRANK

There exists an inordinate amount of spectral data in both public and private astronomical archives that remain severely under-utilized. The lack of reliable open-source tools for analyzing large volumes of spectra contributes to this situation, which is poised to worsen as large surveys successively release orders of magnitude more spectra. In this article I introduce sick, the spectroscopic inference crank, a flexible and fast Bayesian tool for inferring astrophysical parameters from spectra. sick is agnostic to the wavelength coverage, resolving power, or general data format, allowing any user to easily construct a generative model for their data, regardless of its source. sick can be used to provide a nearest-neighbor estimate of model parameters, a numerically optimized point estimate, or full Markov Chain Monte Carlo sampling of the posterior probability distributions. This generality empowers any astronomer to capitalize on the plethora of published synthetic and observed spectra, and make precise inferences for a host of astrophysical (and nuisance) quantities. Model intensities can be reliably approximated from existing grids of synthetic or observed spectra using linear multi-dimensional interpolation, or a Cannon-based model. Additional phenomena that transform the data (e.g., redshift, rotational broadening, continuum, spectral resolution) are incorporated as free parameters and can be marginalized away. Outlier pixels (e.g., cosmic rays or poorly modeled regimes) can be treated with a Gaussian mixture model, and a noise model is included to account for systematically underestimated variance. Combining these phenomena into a scalar-justified, quantitative model permits precise inferences with credible uncertainties on noisy data. I describe the common model features, the implementation details, and the default behavior, which is balanced to be suitable for most astronomical applications. Using a forward model on low-resolution, high signal-to-noise ratio spectra of M67 stars reveals atomic diffusion processes on the order of 0.05 dex, previously only measurable with differential analysis techniques in high-resolution spectra. sick is easy to use, well-tested, and freely available online through GitHub under the MIT license.

79 ASTRONOMY AND ASTROPHYSICS↗

Spatially Resolved Performance Analysis for Perovskite Solar Cells

This review explores the current state of the art in spatially resolved characterization of mixed-halide perovskite solar cells. As the size of perovskite cells and modules continues to grow, quantification of the spatial distribution of key cell parameters will become increasingly valuable in predicting ultimate cell-level performance and tracking process homogeneity. Here, both high resolution microscopic approaches using scanning techniques and camera-based methods for full-area cell and/or module analysis are discussed. The value of this local data in predicting performance losses at the cell level is particularly emphasized. Measurable physical parameters sensitive to losses of voltage, current, fill factor, and efficiency are discussed together with selected experimental results. It is demonstrated that a combination of spatially resolved cell parameter mapping/imaging can be used to quantitatively discriminate various loss contributions at high resolution. The impact and control of inhomogeneities become particularly important when upscaling from small devices to large formats compatible with industrial mass production.

14 SOLAR ENERGY↗