Search NASA⌕ Search

SEARCH · Search NASA

Results for “High vacuum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Comment on Comment on “Anomalous structural recovery in the near glass transition range in a polymer glass: Data revisited in light of temperature variability in vacuum oven‐based experiments”*

Abstract Cangialosi, Alegría, and Colmenero have made a comment on a paper of ours [Polym. Eng. Sci. 2022:1–13], in which we discussed the concern that the enthalpy recovery data reported by Cangialosi and co‐workers [Phys. Rev. Lett. 2013;111(9):095701] for polystyrene aged up to 15 K below glass transition temperature was anomalous and contradicted existing experimental results from the literature over a similar range of aging conditions. Their response shifts the focus away from the raised questions about their experimental results and attempts to invalidate the data that we cited in support of our argument. Here we respond to the comment and add additional analysis that suggests the structural recovery response of glassy materials exhibits smooth behavior over the full range of measurements, up to 7 or 8 logarithmic decades. We do this by referring to the work on the intrinsic isotherm down‐jump and memory responses of poly(vinyl acetate) between 40°C and 15°C over six logarithmic decades by Kovacs [Fortsch. Hochpolym. Fo. 1963;3(1/2):394–508], the small‐strain tensile creep of poly(vinyl chloride) quenched from 90°C to 40°C (approximately 40°C below T g ) over seven logarithmic decades from Struik [Polym Eng. Sci., 1977;17:165–173], and the volume recovery behavior for aging times up to 3 months in a temperature range between 95°C and −50°C by Greiner and Schwarzl [Rheol. Acta. 1984;23(4):378–395]. We also add discussion that an isothermal aging procedure using a vacuum oven is highly vulnerable to temperature errors due to the problem of good temperature control when the heat transfer mechanism is primarily radiative.

Jin, Shuang↗

Preparation of a uranium monocarbide anode and electrochemical characterization in molten LiCl-KCl-UCl 3

Porous uranium carbide (UC) pellets possessing moderate electrical conductivity were synthesized by reaction of UO 2 with graphite at temperatures up to 1550°C under rough vacuum. Conversions as high as 98% were achieved at soak times of 2-4 hours. The electrochemistry of the UC pellets in molten LiCl-KCl-6.5 wt% UCl 3 was explored using a variety of techniques including DC polarization methods, cyclic voltammetry, chronopotentiometry and bulk electrolysis. Here, the electrode reaction for anodic dissolution was found to be kinetically controlled by dissociation of UC to a transition state complex that was hypothesized to consist of a uranium atom partially complexed by chloride ions. Precise measurements of current efficiencies using chronopotentiometry indicated upper limits of 90.9 ± 3.4% and 98.3 +1.7/-3.7% for anode and cathode, respectively, when operating at anodic overpotentials near +300 mV. Bulk electrolysis of a UC pellet performed by passing 98% of the theoretical charge resulted in nearly complete recovery of its uranium content as highly pure metal at the cathode.

36 MATERIALS SCIENCE↗

Extending the family of reduced [Mn 12 O 12 (O 2 CR) 16 (H 2 O) x ] n- complexes, and their sensitivity to environmental factors

Here, the family of reduced [Mn 12 O 12 (O 2 CR) 16 (H 2 O) 4 ] n- (n = 1, 2) single-molecule magnets (SMMs) has been expanded with the synthesis of new members using I - as a stoichiometric one-electron reducing agent of the neutral n = 0 complexes. Electrochemical data, 1 H NMR spectra of the [Mn 12 O 12 (O 2 CCH 2 Cl) 16 (H 2 O) 3 ] 0,-,2- salts, and the crystal structures of two complexes, (PPh 4 )[Mn 12 O 12 (O 2 CCHCl 2 ) 16 (H 2 O) 4 ] and (PPh 4 ) 2 [Mn 12 O 12 (O 2 CCH 2 Cl) 16 (H 2 O) 3 ] have been obtained. For (PPh 4 ) 2 [Mn 12 O 12 (O 2 CCH 2 Cl) 16 (H 2 O) 3 ], the data confirm an S = 10 ground state, and magnetization vs dc field scans on a pristine crystal exhibit hysteresis loops possessing steps due to quantum tunneling of magnetization (QTM). In addition, two forms of the cluster have been identified in the crystal with distinctly different relaxation barriers, with the faster-relaxing form being the majority one in pristine crystals from mother liquor, and the slower-relaxing one becoming the majority one in vacuum-dried samples. Similar behavior is seen for (PPh 4 )[Mn 12 O 12 (O 2 CCHCl 2 ) 16 (H 2 O) 4 ] with an S = 19 / 2 ground state, which shows three forms to be present in the hysteresis loops of a pristine crystal, all converting to a slow-relaxing form on vacuum-drying. High-frequency EPR spectra of the latter confirm a high axial anisotropy with $\mathcal{D}$ = -0.477 cm -1 and rationalize its effective relaxation barrier U eff = 57 K. The combined work emphasizes a high sensitivity of such ultra-small nanomagnets to environmental influences, affecting their properties significantly, especially their quantum properties that are so important to many potential new 21st century applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoscale Tracking of the High-Temperature Spin-State Transition in LaCoO 3

The high-temperature spin and electronic transitions in LaCoO 3 have recently been leveraged to create neuromorphic (brain-inspired) devices. While these devices have shown the potential for impactful functionality in next-generation computing systems, the nanoscale dynamics of the spin and electronic transitions that underlie their operation are not well understood. Inhomogeneities related to interfaces, electrode contacts, strain, and crystal defects can all affect device performance, making nanoscale characterization of the transitions essential for producing consistent and reliable devices. Here, we demonstrate the first nanoscale in situ measurement of the spin transition in LaCoO 3 at device-relevant temperatures (25–325 °C) over length scales of tens of nanometers using STEM-EELS. This measurement is enabled by an Al 2 O 3 coating, which prevents unwanted reduction of the LaCoO 3 specimen at high temperature and vacuum. The detailed understanding of LaCoO 3 transition dynamics enabled by such measurements will be crucial for optimizing LaCoO 3 -based neuromorphic devices and increasing reliability for real-world application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Metal oxide barrier layers for terrestrial and space perovskite photovoltaics

Perovskite photovoltaics are attractive for both terrestrial and space applications. Although terrestrial conditions require durability against stressors such as moisture and partial shading, space poses different challenges: radiation, atomic oxygen, vacuum and high-temperature operation. Here we demonstrate a silicon oxide layer that hardens perovskite photovoltaics to critical space stressors. A 1-um-thick silicon oxide layer evaporated atop the device contacts blocks 0.05 MeV protons at fluences of 10 15 cm -2 without a loss in power conversion efficiency, which results in a device lifetime increase in low Earth orbit by x20 and in highly elliptical orbit by x30. Silicon-oxide-protected Cs 0.05 (MA 0.17 FA 0.83 ) 0.95 Pb(I 0.83 Br 0.17 ) 3 ) (MA, methylammonium; FA, formamidinium cation) and CsPbI 2 Br cells survive submergence in water and N,N-dimethylformamide. Furthermore, moisture tolerance of Sn-Pb and CsPbI 2 Br devices is boosted. Devices are also found to retain power conversion efficiencies on exposure to alpha irradiation and atomic oxygen. So, this barrier technology is a step towards lightweight packaging designs for both space and terrestrial applications.

14 SOLAR ENERGY↗

Photoabsorption and photoionization of N2 near the first ionization threshold

The photoabsorption and photoionization spectra of molecular nitrogen, N2, near the first ionisation threshold display numerous intense resonances that have not been satisfactorily assigned to date. Principal among these is a pair of broad resonances between 126,200 and 126,600 cm−1 commonly referred to as the ”cathedral” bands. Here, we present new double-resonance photoionization spectra in this region recorded via the 𝑎′′ 1Σ+ 𝑔,𝑣′=0 intermediate state as well as new high-resolution, vacuum-ultraviolet photoabsorption spectra of 14N2,14N15N, and 15N2 to provide additional insight into the assignment of these features. Progress towards a fully consistent interpretation of the existing data on these bands is discussed, and a route towards a comprehensive description of the N2 absorption spectrum up to the 𝐵 2Σ+ 𝑢 state of N+ 2 is proposed.

Nitrogen, vacuum ultraviolet absorption, photoioni↗

Surrogate models for linear response

Linear response theory is a well-established method in physics and chemistry for exploring excitations of many-body systems. In particular, the quasiparticle random-phase approximation (QRPA) provides a powerful microscopic framework by building excitations on top of the mean-field vacuum; however, its high computational cost limits model calibration and uncertainty quantification studies. Here, we present two complementary QRPA surrogate models and apply them to study response functions of finite nuclei. One is a reduced-order model that exploits the underlying QRPA structure, while the other utilizes the recently developed parametric matrix model algorithm to construct a map between the system’s Hamiltonian and observables. Our benchmark applications, the calculation of the electric dipole polarizability of 180 Yb and the 𝛽-decay half-life of 80 Ni, show that both emulators can achieve 0.1%–1% accuracy while offering a 6–7 orders of magnitude speedup compared to state-of-the-art QRPA solvers. These results demonstrate that the developed QRPA emulators are well positioned to enable Bayesian calibration and large-scale studies of computationally expensive physics models describing the properties of many-body systems.

Beta decay↗

Electron Dynamics Within a MITL Containing a Load

In this paper, we derive the vacuum electric fields within specific cylindrically symmetric magnetically insulated transmission lines (MITLs) in the limit of an infinite speed of light for an arbitrary time-dependent current. We focus our attention on two types of MITLs: the radial MITL and a spherically curved MITL. We then simulate the motion of charged particles, such as electrons, present in these MITLs due to the vacuum fields. In general, the motion of charged particles due to the vacuum fields is highly nonlinear since the fields are nonlinear functions of spatial coordinates and depend on an arbitrary time-dependent current drive. Using guiding center theory, however, one can describe the gross particle kinetics using a combination of $\textbf {E} \times \textbf {B}$ and $\nabla B$ drifts. In addition, we compare our approximate inner MITL field models and particle kinetics with those from a fully electromagnetic simulation code. We find that the agreement between the approximate model and the electromagnetic simulations is excellent.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of suspended membrane waveguides towards a photonic atom trap integrated platform

We demonstrate an optical waveguide device, capable of supporting the high, in-vacuum, optical power necessary for trapping a single atom or a cold atom ensemble with evanescent fields. Our photonic integrated platform, with suspended membrane waveguides, successfully manages optical powers of 6 mW (500 μ m span) to nearly 30 mW (125 μ m span) over an un-tethered waveguide span. This platform is compatible with laser cooling and magneto-optical traps (MOTs) in the vicinity of the suspended waveguide, called the membrane MOT and the needle MOT, a key ingredient for efficient trap loading. We evaluate two novel designs that explore critical thermal management features that enable this large power handling. This work represents a significant step toward an integrated platform for coupling neutral atom quantum systems to photonic and electronic integrated circuits on silicon.

36 MATERIALS SCIENCE↗

Portable Soft X-Ray Diagnostics for Transformative Fusion-Energy Concepts (Final Scientific/Technical Report)

A time-gated extreme-ultraviolet spectrometer was fielded on a transformative fusion-energy device, FuZE-Q at Zap Energy, Inc. (ZEI), a sheared-flow-stabilized z-pinch. Plasma emission spectra were collected in the 5–40 nm wavelength (30–250 eV) range. This was the first time a direct-vacuum-coupled, high-voltage, deposition-sensitive diagnostic was fielded on this type of dense-plasma fusion device. To overcome the special challenges of such a coupling, a unique, highly effective implementation was developed, with fast (10-ns risetime) pulsed high-voltage electronics and a multi-stage differential pumping system. This enabled the UNR spectrometer to collect three independently timed spectra per FuZE-Q shot while also protecting sensitive internal components. Analysis of line emission identified oxygen (N-, C-, B-, Be-, Li-, and He-like O), peaking in intensity shortly after maximum current (>500 kA). Spectral databases and collisional-radiative modeling have been used to identify impurities and estimate edge-plasma temperatures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High Temperature Mechanical Behavior of Refractory Alloys with Digital Image Correlation

Gas turbine efficiency is typically limited by the maximum allowable temperature for components at the inlet side and in the hot gas flow. Refractory alloys and SiC/SiC ceramic-matrix composites (CMCs) are promising candidates for advancing operating temperatures beyond those of Ni-based alloys (>1200 °C). Refractory alloys are more suitable than SiC/SiC CMCs for dynamic components, due to the latter's low toughness and ductility. However, it is well known that refractory alloys suffer from poor oxidation behavior under service lifetimes and conditions, leading to embrittlement concerns. The ARPA-E ULTIMATE program has set out to combine new alloys with advanced coatings to mitigate oxidation/embrittlement effects, while increasing the mechanical performance benefits of refractory materials. Low oxygen (inert gas) or vacuum systems are needed to assess high temperature mechanical performance of developed alloys. To investigate the environmental sensitivity of candidate alloys and develop high temperature testing capabilities, four argon tensile frames were upgraded as well as a single vacuum system at Oak Ridge National Laboratory. Digital image correlation was incorporated into the vacuum frame allowing for surface strain determination and refined insight into thermomechanical response. Creep testing was performed at 1300 °C on two alloys, C-103 and MHC in vacuum and high purity argon environments. The Mo-based alloy showed less sensitivity to oxygen, indicating that testing in well-controlled argon environments may be suitable. The C-103 alloy demonstrated a stronger sensitivity to oxygen in the well-controlled argon environment, illustrating the need for the developed vacuum testing capabilities. “Small” 25 mm and “large” 76 mm MHC specimens showed comparable results in terms of strain rate during creep testing and ultimate tensile strength during tensile testing, suggesting the viability of smaller geometries that use less material of advanced developmental alloys.

Bell, Sam↗

Electron Cloud Simulations for the Electron-Ion Collider in Brookhaven National Laboratory

For high-intensity circular accelerators and storage rings, if the secondary electron emission yield (SEY) of the vacuum chamber surfaces is high, an EC (Electron Cloud) could build up with the passage of the circulating beam. The presence of EC can strongly affect the beam quality, such as transverse instabilities, transverse emittance growth, and beam loss. Furthermore, the heat load from EC can exceed the available cryogenic capability. For the RHIC superconducting (SC) arc magnets, to be used for the hadron storage ring of the Electron-Ion Collider (EIC), the dynamic heat load budget is 0.5 W/m to the 4.5 K stainless steel beam pipe. This can limit the maximum beam bunches or intensity of the EIC, hence diminishing the luminosity provided by the EIC. The EC has affected the beam instability and significantly contributed to cryogenic heat load in the Large Hadron Collider (LHC). Positron storage rings for which ECs have been a critical factor in the design and performance include KEKB in Japan and EC buildup remains one of the concerns for future high-intensity accelerators design. EC considerations have driven the SuperKEKB collider design and the positron damping ring for the proposed International Linear Collider (ILC). The LHC luminosity upgrade is contingent on reducing the bunch spacing to 25 ns; at this bunch spacing, severe EC buildup has been observed. The success of the upgrade is likely contingent on limiting EC buildup. To study the EC heat load, we did some EC simulations with PyECLOUD code for the dipole, quadrupole, sextupole magnets, and the warm (drift) section of the EIC hadron storage ring. PyECLOUD is an EC simulation code developed by CERN. The code has been validated and used to study EC in the LHC, SPS, and PS. To eliminate EC buildup, the sources of electrons must be minimized. First, we will reduce the production of electrons due to residual gas ionization by specifying the maximum gas density, which requires a vacuum chamber with low electron-stimulated desorption (ESD) yields and a sufficient (preferably distributed) pumping speed. Second, we should reduce the secondary electrons with a lower secondary electron yield (SEY) material.

43 PARTICLE ACCELERATORS↗

Nondestructive Evaluation of Rexolite Insulators for the Purpose of Monitoring the Structural Health of Particle Accelerator

Rexolite is a cross-linked polystyrene plastic with stable electrical properties into the gigahertz frequency range. The ability to withstand high voltage makes Rexolite one of the most used materials as insulators for particle accelerators. Although, Rexolite’s poor outgassing performance relative to traditional vacuum materials such as stainless steel or aluminum deems the necessity to treat Rexolite prior to its use as insulators. Insulators are mandatory for an accelerator system because a uniform electric field is required to ensure the alignment of the accelerated particles. Furthermore, to operate properly, a particle accelerator is required to maintain a high vacuum or even an ultrahigh vacuum. Although, because outgassing is the major contributor to the gas load of a vacuum system, Rexolite insulators with uncontrolled outgassing characteristics can severely damage the particle accelerator. Disassembly and reassembly of a complex system like a particle accelerator is also time consuming.

36 MATERIALS SCIENCE↗

Materials and technological processes for High-Gradient accelerating structures: new results from mechanical tests of an innovative braze-free cavity.

Pure oxygen-free high-conductivity copper is a widely used material for manufacturing accelerating cavities working at room temperature. Several studies attempted to explain limitations associated with the maximum allowed field gradients and the behaviour of vacuum RF breakdown in copper accelerating structures through generation and movement of dislocations under stresses associated with RF electric and magnetic fields. Pure copper and also copper alloys undergo mechanical and thermal treatments to be hardened and strengthened during manufacturing, although their mechanical properties significantly change after heating above 590°C. High temperature brazing and diffusion bonding are assembly methods widely used to manufacture ultra-high vacuum accelerating devices. However, these processes, occurring at about 800–1000°C, significantly affect the mechanical properties of copper and copper alloys. We introduce here a novel Tungsten Inert Gas welding procedure, which is fast and keeps the high-gradient surfaces of the cavity and other components well below the copper annealing temperature. This process may be successfully used to manufacture copper-based accelerating components. This technology further preserves the hardness and cleanliness of copper in order to achieve the maximum accelerating gradient.

47 OTHER INSTRUMENTATION↗

Salt Sampling FY21 Technical Report

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches to enable high-precision in-process salt sample analysis to improve the timeliness of sampling-based accountancy measurements. Tools currently under development in support of this goal include (1) a modular vacuum sampler with an accompanying sample handling method for coupling vacuum sampling with high-precision at-line sample analysis, (2) a pneumatic sample generator that enables high-throughput sample analysis to improve the precision of existing analytical techniques, and (3) a windowless flow cell to enable on-line optical analysis of molten salt in a sampling loop. Compared to point sampling approaches (i.e., dip probes), vacuum sampling systems and on-line sampling loops facilitate access to a larger cross-section of a process fluid. This is known to improve the characterization of the process fluid by producing more representative samples and by enabling the analysis of a larger cross section of the fluid. A vacuum sampling approach for molten salts eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. In FY21, two methods for integrating a vacuum sampler with a pneumatic sample generator were tested. These included direct fluidic coupling and coupling using a solid salt transfer mechanism. Solid salt transfer was ultimately selected over fluidic coupling, primarily to enable the transport of samples over longer distances to support automated at-line integration with high-precision techniques (such as microcalorimetry) that cannot withstand the extreme conditions near an electrorefining process. To facilitate rapid solid salt coupling, new mechanisms were developed for rapidly charging and discharging salt sample tubes at the vacuum sampler and pneumatic sample generator, respectively. While the charging mechanism will be deployed in FY22, the tube transfer method and discharge mechanism were tested in FY21. These were deployed at one of Argonne’s engineering-scale electrorefiners to implement at-line high-throughput pneumatic micro-sample generation capabilities. The method was used to generate precise uranium- and lanthanide-bearing electrorefiner micro-samples with the specific dimensions requested by researchers at Los Alamos National Laboratory for use in testing their novel microcalorimeter x-ray techniques. The solid salt transfer mechanism proved not only to be an effective means of integrating the precision sample generator with vacuum sampling, but also improved the performance of the sampler generator. Because the modular sampling approach described here eliminates the need for new high-radiation sample handling capabilities, salt-wetted seals, salt-wetted moving parts, and heated transfer lines outside the electrorefiner, it will address most of the remaining technical challenges for the at-line deployment of high-precision analytical techniques. This will enable significant reductions in the time delay for sampling-based accountancy measurements by eliminating the need for manual off-line sample processing and analysis. On-line optical analysis of molten salt in a sampling loop would provide complementary information to at-line and in-situ techniques. In FY21, an open-aperture molten salt gravity flow cell with windowless optical access to flowing salt was successfully demonstrated. Future work should include the refinement and performance testing of the on-line and at-line sampling tools, integration of additional analysis techniques, stakeholder outreach and collaboration, evaluation of the integrated methods, and analyses to determine how the various tools might fit into an integrated safeguards monitoring system of unattended near real time monitoring tools.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Irradiation-induced reactions at the CeO 2 /SiO 2 /Si interface

The influence of high-energy (1.6 MeV) Ar 2+ irradiation on the interfacial interaction between cerium oxide thin films (~15 nm) with a SiO 2 /Si substrate is investigated using transmission electron microscopy, ultrahigh vacuum x-ray photoelectron spectroscopy (XPS), and a carbon monoxide (CO) oxidation catalytic reaction using ambient pressure XPS. The combination of these methods allows probing the dynamics of vacancy generation and its relation to chemical interactions at the CeO 2 /SiO 2 /Si interface. The results suggest that irradiation causes amorphization of some portion of CeO 2 at the CeO 2 /SiO 2 /Si interface and creates oxygen vacancies due to the formation of Ce 2 O 3 at room temperature. The subsequent ultra-high-vacuum annealing of irradiated films increases the concentration of Ce 2 O 3 with the simultaneous growth of the SiO 2 layer. Interactions with CO molecules result in an additional reduction of cerium and promote the transition of Ce 2 O 3 to a silicate compound. Furthermore, thermal annealing of thin films exposed to oxygen or carbon monoxide shows that the silicate phase is highly stabile even at 450 °C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗