Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGE TUBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Design and calibration of a vacuum compatible scanning tunneling microscope

A vacuum compatible scanning tunneling microscope was designed and built, capable of imaging solid surfaces with atomic resolution. The single piezoelectric tube design is compact, and makes use of sample mounting stubs standard to a commercially available surface analysis system. Image collection and display is computer controlled, allowing storage of images for further analysis. Calibration results from atomic scale images are presented.

Abel, Phillip B.↗

Multi Spectral Imaging System

An optical imaging system provides automatic co-registration of a plurality of multi spectral images of an object which are generated by a plurality of video cameras or other optical detectors. The imaging system includes a modular assembly of beam splitters, lens tubes, camera lenses and wavelength selective filters which facilitate easy reconfiguration and adjustment of the system for various applications. A primary lens assembly generates a real image of an object to be imaged on a reticle which is positioned at a fixed length from a beam splitter assembly. The beam splitter assembly separates a collimated image beam received from the reticle into multiple image beams, each of which is projected onto a corresponding one of a plurality of video cameras. The lens tubes which connect the beam splitter assembly to the cameras are adjustable in length to provide automatic co-registration of the images generated by each camera.

Spiering, Bruce A.↗

Using Digital Radiography To Image Liquid Nitrogen in Voids

Digital radiography by use of (1) a field-portable x-ray tube that emits low-energy x rays and (2) an electronic imaging x-ray detector has been found to be an effective technique for detecting liquid nitrogen inside voids in thermal-insulation panels. The technique was conceived as a means of investigating cryopumping (including cryoingestion) as a potential cause of loss of thermal insulation foam from space-shuttle external fuel tanks. The technique could just as well be used to investigate cryopumping and cryoingestion in other settings. In images formed by use of low-energy x-rays, one can clearly distinguish between voids filled with liquid nitrogen and those filled with gaseous nitrogen or other gases. Conventional film radiography is of some value, but yields only non-real-time still images that do not show time dependences of levels of liquids in voids. In contrast, the present digital radiographic technique yields a succession of images in real time at a rate of about 10 frames per second. The digitized images can be saved for subsequent analysis to extract data on time dependencies of levels of liquids and, hence, of flow paths and rates of filling and draining. The succession of images also amounts to a real-time motion picture that can be used as a guide to adjustment of test conditions.

Cox, Dwight↗

Temporal Evolution of SL-9 Impact Sites on Jupiter and Global Maps of Jupiter from Multi-Observatory Visible and Infrared Images

The objective of this research was to investigate the temporal behavior of the impact features on Jupiter created by the fragments of the Shoemaker Levy-9 comet that collided with the planet in July 1994. The primary observations used in the study were ground based images of Jupiter acquired from the Swedish Solar Vacuum Tube on the island of La Palma in the Canary Islands. The measurement of position of the impact features in images acquired immediately after the impact over a period of a few days revealed that the apparent drift rates were too high and that a repetitive pattern could be seen in the longitude position on successive rotations. This could be explained only by the fact that the measured longitudes of the impact sites were being affected by parallax due to a significant elevation of the impact debris above the nominal cloud top altitude value used for image navigation. Once the apparent positions are analyzed as a function of the meridian angle, the parallax equation can be used to infer the height of the impact features above the cloud deck, once the true impact position (longitude) for the feature is known. Due to their inherent high spatial resolution, the HST measurements of the impact site locations have been accepted widely. However, these suffer from the parallax themselves since few of them were obtained at central meridian. Ground based imaging have the potential to improve this knowledge as they do observe most of the impact sites on either side of the central meridian, except for the degraded resolution. Measurements over a large number of images enables us to minimize the position error through regression and thus estimate both the actual impact site location devoid of parallax bias, and also of the altitude level of the impact debris above the cloud deck. With rapid imaging there is the potential to examine the time evolution of the altitude level. Several hundred ground based images were processed, navigated and subjected to the impact site location measurements. HST images were also acquired and used to calibrate the results and to improve the sample. The resources available enabled an in-depth study only of impact site A, however, many more images have since become available through the global network observations through Lowell Observatory.

Limaye, Sanjay S.↗

A Digital Video Model Deformation System

The use of slid-state array cameras and a PC controlled image acquisition system to measure model deformation in a wind tunnel is discussed. This digital system is an improvement to an earlier video model deformation system used at the National Transonic Facility (NTF) which employed high-resolution tube cameras and required the manual measurement of targets on video hardcopy images. The new system eliminates both the vibration-induced distortion associated with tube cameras and the manual readup of video images necessary in the earlier version. Camera calibration and data reduction procedures necessary to convert pixel image plane data from two cameras into wing deflections are presented. Laboratory tests to establish the uncertainty of the new system with the geometry to be used at the NTF are described.

Burner, A. W.↗

Design concept for improved photo-scan tube

Conceptual photo-scan tube avoids complexity of internal beam scanning and beam-current adjustment by optical scan readout. It differs from a conventional image orthicon in its use of an external oscilloscope tube.

Malling, L. R.↗

Thermal Nondestructive Characterization of Corrosion in Boiler Tubes by Application fo a Moving Line Heat Source

Wall thinning in utility boiler waterwall tubing is a significant inspection concern for boiler operators. Historically, conventional ultrasonics has been used lor inspection of these tubes. This technique has proved to be very labor intensive and slow. This has resulted in a "spot check" approach to inspections, making thickness measurements over a relatively small percentage of the total boiler wall area. NASA Langley Research Center has developed a thermal NDE technique designed to image and quantitatively characterize the amount of material thinning present in steel tubing. The technique involves the movement of a thermal line source across the outer surface of the tubing followed by an infrared imager at a fixed distance behind the line source. Quantitative images of the material loss due to corrosion are reconstructed from measurements of the induced surface temperature variations. This paper will present a discussion of the development of the thermal imaging system as well as the techniques used to reconstruct images of flaws. The application of the thermal line source, coupled with this analysis technique, represents a significant improvement in the inspection speed for large structures such as boiler waterwalls while still providing high-resolution thickness measurements. A theoretical basis for the technique will be presented thus demonstrating the quantitative nature of the technique. Further, results of laboratory experiments on flat Panel specimens with fabricated material loss regions will be presented.

Cramer, K. Elliott↗

The Coronal Veil

Coronal loops, seen in solar coronal images, are believed to represent emission from magneticflux tubes withcompact cross sections. We examine the 3D structure of plasma above an active region in a radiativemagnetohydrodynamic simulation to locate volume counterparts for coronal loops. In many cases, a loop cannot belinked to an individual thin strand in the volume. While many thin loops are present in the synthetic images, thebright structures in the volume are fewer and of complex shape. We demonstrate that this complexity can formimpressions of thin bright loops, even in the absence of thin bright plasma strands. We demonstrate the difficulty ofdiscerning from observations whether a particular loop corresponds to a strand in the volume, or a projectionartifact. We demonstrate how apparently isolated loops could deceive observers, even when observations frommultiple viewing angles are available. While we base our analysis on a simulation, the mainfindings areindependent from a particular simulation setup and illustrate the intrinsic complexity involved in interpretingobservations resulting from line-of-sight integration in an optically thin plasma. We propose alternativeinterpretation for strands seen in Extreme Ultraviolet images of the corona. The“coronal veil”hypothesis ismathematically more generic, and naturally explains properties of loops that are difficult to address otherwise—such as their constant cross section and anomalously high density scale height. We challenge the paradigm ofcoronal loops as thin magneticflux tubes, offering new understanding of solar corona, and by extension, of othermagnetically confined bright hot plasmas

A Malanushenko↗

Experimental masking of RBV images to reduce stationary residual inaccuracies in radiometric correction

Return beam vidicon tube calibration data are used to correct spatially non-uniform radiance response in individual vidicons, during post-acquisition signal processing. However, examination of different ERTS-1 RBV-1, -2, and -3 image scenes showed stationary, repetitive residual inaccuracies in shading correction, large enough to affect qualitative and quantitative image analyses. Photographic masks designed to reduce residual shading were prepared from RBV-1, -2, and -3 images of a relatively cloud-free ocean scene of uniform reflectance. When applied to other RBV scenes, the masks enabled more closely corrected RBV images to be printed. Illustrations are given of RBV-1 image before and after correction, compared with an equivalent MSS spectral image of the same scene.

Ross, D. S.↗

High resolution studies of sunspots and flux tubes

This contract is for a three-year research study of sunspots and magnetic flux tubes in the solar atmosphere, using tunable filter images collected with a CCD camera during observing runs at the Canary Islands observatories in Spain. The best observations are analyzed and compared with theoretical models, to study the structure and dynamics of sunspots, their connections with surrounding magnetic fields, and the properties and evolution of smaller flux tubes in plage and quiet sun. Scientific results are reported at conferences and published in the appropriate journals. The contract is being performed by the Solar and Astrophysics Laboratory, part of the Lockheed Palo Alto Research Laboratory (LPARL) of the Research and Development Division (RDD) of Lockheed Missiles and Space Co., Inc. (LMSC). The principal investigator is Dr. Alan Title, and the research is done by him and other scientific staff at LPARL and Solar Physics Research Corporation (SPRC), often in collaboration with visiting scientists and students from other institutions. Highlights during this reporting period include completing the final version of a paper on the Evershed effect, writing a paper on magnetic diffusion, continuing work on contrast of small flux tubes, and work on the development of new models to interpret our sunspots observations.

Title, Alan↗

Mariner 10 star photography

Two identical television cameras, each having a long and short focal-length capability, were carried aboard the spacecraft for the reconnaissance of Venus and Mercury. These telescopes were used in conjunction with a filter-wheel assembly and a focal-plane shutter to provide an image on a slow-scan vidicon tube. The results obtained with this system are discussed, giving attention to aspects of sensitivity and questions related to focal length and geometric distortion.

Thorpe, T. E.↗

Measurement of subcoat thickness by characteristic x-rays

Technique employs x-ray scanning system to measure thickness of topcoat and subcoat of heat shields and other ceramic materials. System scans sample in raster pattern and depicts image of structure on cathode-ray-tube for viewing or photocopying within seconds.

Harris, W. J.↗

An imaging system for quantitive surface temperature mapping using two-color thermographic phosphors

A technique for obtaining detailed quantitative temperature distributions on test models in hypersonic wind tunnels is presented. This technique is based on the ratio of blue to green (450, 520 nm) emission from an UV (365 nm) excited phosphor coating. Separately filtered images are recorded from a three-tube color camera, utilizing off-the-shelf front-end video optics to discriminate wavelengths. Two demonstration studies in a 31-inch Mach 10 tunnel are discussed. One study presents the windward surface temperature-time history for a transatmospheric vehicle, and the other illustrates nosetip heating on a spherically blunted slender cone.

Buck, Gregory M.↗

The Track Imaging Cerenkov Experiment

We describe a dedicated cosmic-ray telescope that explores a new method for detecting Cerenkov radiation from high-energy primary cosmic rays and the large particle air shower they induce upon entering the atmosphere. Using a camera comprising 16 multi-anode photomultiplier tubes for a total of 256 pixels, the Track Imaging Cerenkov Experiment (TrICE) resolves substructures in particle air showers with 0.086deg resolution. Cerenkov radiation is imaged using a novel two-part optical system in which a Fresnel lens provides a wide-field optical trigger and a mirror system collects delayed light with four times the magnification. TrICE records well-resolved cosmic-ray air showers at rates ranging between 0.01-0.1 Hz.

Wissel, S. A.↗

The Track Imaging Cerenkov Experiment

We describe a. dedicated cosmic-ray telescope that explores a new method for detecting Cerenkov radiation from high-energy primary cosmic rays and the large particle air shower they induce upon entering the atmosphere. Using a camera comprising 16 multi-anode photomultiplier tubes for a total of 256 pixels, the Track Imaging Cerenkov Experiment (TrICE) resolves substructures in particle air showers with 0,086 deg resolution. Cerenkov radiation is imaged using a novel two-part optical system in which a Fresnel lens provides a wide-field optical trigger and a mirror system collects delayed light with four times the magnification. TrICE records well-resolved cosmic-ray air showers at rates ranging between 0.01-0.1 Hz.

Wissel, S. A.↗

Conceptual Design of a Test Section for a Cryogenic Transfer Line Experiment

This project presents the development of a comprehensive computer-aided design (CAD) model for the Transfer Line test section, which is an upcoming test module for the Flow Boiling and Condensation Experiment (FBCE) aboard the International Space Station. The FBCE aims to serve as the primary platform to study two-phase flow in microgravity, and the Transfer Line module aims to utilize its existing hardware to study cryogenic chilldown; a critical component of cryogenic propellant transfer in space. The CAD model was created using SolidWorks software and includes the test section’s main components: a heat transfer line, a flow visualization line, insulation, high-speed visible imaging, and infrared imaging. The heat transfer line primarily consists of a stainless steel tube that will be heated via Joule heating. The flow visualization line consists of segmented Indium-Titanium-Oxide coated sapphire tubes, which allow for visualization of flow regimes by high-speed and infrared cameras, similar thermal properties as the stainless steel tube, and Joule heating via the ITO coating resistance. Polyether Ether Ketone was used to insulate and encapsulate the two sections. High-speed visible imaging and infrared imaging were also incorporated to view the propagation of fluid during inverted annular flow and map out the thermal profile of the ITO-coated sapphire tube. This model serves as the guiding concept design for the Transfer Line project and will assist the project team during future safety reviews and concept design reviews. Overall, this work is significant in two-phase flow research and offers a promising path towards an established facility for cryogenic transfer line research in microgravity.

Flow boiling↗

Development of television tubes for the large space telescope

Princeton Observatory has been working for several years under NASA sponsorship to develop television type sensors to use in place of photographic film for space astronomy. The performance of an SEC-vidicon with a 25 mm x 25 mm active area, MgF2 window, and bi-alkali photocathode is discussed. Results from ground based use on the Coude spectrograph of the 200-inch Hale telescope are included. The intended use of this tube in an echelle spectrograph sounding rocket payload and on Stratoscope 2 for direct high resolution imagery is also discussed. The paper also discusses the large space telescope image sensor requirements and the development of a larger television tube for this mission.

Lowrance, J. L.↗