Search NASA⌕ Search

SEARCH · Search NASA

Results for “INDUCTION SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Proteomic analysis of bronchoalveolar lavage fluid proteins from mice infected with Francisella tularensis ssp novicida

Francisella tularensis causes the zoonosis tularemia in humans and is one of the most virulent bacterial pathogens. We utilized a global proteomic approach to characterize protein changes in bronchoalveolar lavage fluid from mice exposed to one of three organisms, F. tularensis ssp. novicida, an avirulent mutant of F. tularensis ssp. novicida (F.t. novicida-ΔmglA); and Pseudomonas aeruginosa. The composition of BALF proteins was altered following infection, including proteins involved in neutrophil activation, oxidative stress and inflammatory responses. Components of the innate immune response were induced including the acute phase response and the complement system, however the timing of their induction varied. Francisella tularensis ssp. novicida infected mice do not appear to have an effective innate immune response in the first hours of infection, however within 24 hours they show an upregulation of innate immune response proteins. This delayed response is in contrast to P. aeruginosa infected animals which show an early innate immune response. Likewise, F.t. novicida-ΔmglA infection initiates an early innate immune response, however this response is dimished by 24 hours. Finally, this study identifies several candidate biomarkers, including Chitinase 3-like-1 (CHI3L1 or YKL-40) and peroxiredoxin 1, that are associated with F. tularensis ssp. novicida but not P. aeruginosa infection.

59 BASIC BIOLOGICAL SCIENCES↗

Synchrotron Soft X-ray Studies of Single-Walled Carbon Nanotubes Functionalized by Radio-Frequency SF{sub 6} Plasma

Single-walled carbon nanotubes have been functionalized using an inductively coupled radio-frequency plasma system with SF{sub 6}, O{sub 2} and H{sub 2}O plasmas. Samples were characterized using synchrotron soft X-ray photoemission spectroscopy. The influence of plasma power has been investigated along with the effect of gaseous mixtures. It has been found that oxygen has a strong influence over the extent of fluorination both as an impurity in the SF{sub 6} plasma and in the form of surface oxygen content on the nanotubes prior to exposure. The presence of sulfur in samples after exposure has until now been considered non-existent but using the synchrotron source, its presence has been noted in very small concentrations.

36 MATERIALS SCIENCE↗

Nonlinear inductive response of pinned superconducting vortices in artificial pinning sites

Using the time dependent Ginzburg-Landau equations, we simulate the inductive responses of a variety of thin-film systems containing patterned antidots with different sizes and shapes. The results for all shapes show that the kinetic inductance diverges as the applied current approaches a critical current that is below the BCS depairing current. In conclusion, exploiting the similarity of the observed current-voltage behavior to that of Josephson junctions, we obtain an empirical equation that well fits the inductivity curve as a function of the applied current.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fixed-Speed and Variable-Slip Wind Turbines Providing Spinning Reserves to the Grid: Preprint

As the level of wind penetration increases, wind turbine technology must move from merely generating power from wind to taking a role in supporting the bulk power system. Wind turbines should have the capability to provide inertial response and primary frequency (governor) response so they can support the frequency stability of the grid. To provide governor response, wind turbines should be able to generate less power than the available wind power and hold the rest in reserve, ready to be accessed as needed. This paper explores several ways to control wind turbine output to enable reserve-holding capability. This paper focuses on fixed-speed (also known as Type 1) and variable-slip (also known as Type 2) turbines.

17 WIND ENERGY↗

Parasitic Effects of Grounding Paths on Common-Mode EMI Filter's Performance in Power Electronics Systems

High-frequency common-mode (CM) electromagnetic-interference (EMI) noise is difficult to suppress in electronics systems. EMI filters are used to suppress CM noise, but their performance is greatly affected by the parasitic effects of the grounding paths. In this paper, the parasitic effects of the grounding paths on an EMI filter's performance are investigated in a motor-drive system. The effects of the mutual inductance between two grounding paths are explored. Guidelines for the grounding of CM EMI filters are derived. Simulations and experiments are finally carried out to verify the theoretical analysis.

42 ENGINEERING↗

Guest Editorial Special Issue on Wireless Charging Systems

Wireless power transfer is a safe and convenient method for electric vehicle (EV) charging. And, if designed properly, it can be highly efficient. Applications cover a wide range of power transfer levels from less than a kilowatt to a few hundreds of kilowatts with transfer distances from a few millimeters to a few hundreds of millimeters. Applications also cover stationary, dynamic (in-motion), or quasi dynamic wireless charging systems. Safety is inherent in wireless power transfer systems due to the large airgap separation between the source and load sides, and users do not have to touch any cables, connectors, or plugs at all. With the recent advancements in automation, parking aid systems can be integrated and the wireless charging process can be a simple “park and go” approach without requiring any input from the driver.When applied in motion, wireless charging can be the ultimate end of game in transportation electrification, providing reduced battery size and cost with unlimited range for EVs. This approach is also known as ”charge-on-the-go” or “roadway powered vehicle” concept. While the connected and automated vehicles can self-drive and self-park, they currently cannot self-charge. Furthermore, wireless charging is a key enabling technology for the widespread development and adoption of connected and automated vehicle technology for the future of smart mobility.

33 ADVANCED PROPULSION SYSTEMS↗

The UPR Branch IRE1- bZIP60 in Plants Plays an Essential Role in Viral Infection and Is Complementary to the Only UPR Pathway in Yeast

The unfolded protein response (UPR) signaling network encompasses two pathways in plants, one mediated by inositol-requiring protein-1 (IRE1)-bZIP60 mRNA and the other by site-1/site-2 proteases (S1P/S2P)-bZIP17/bZIP28. As the major sensor of UPR in eukaryotes, IRE1, in response to endoplasmic reticulum (ER) stress, catalyzes the unconventional splicing of HAC1 in yeast, bZIP60 in plants and XBP1 in metazoans. Recent studies suggest that IRE1p and HAC1 mRNA, the only UPR pathway found in yeast, evolves as a cognate system responsible for the robust UPR induction. However, the functional connectivity of IRE1 and its splicing target in multicellular eukaryotes as well as the degree of conservation of IRE1 downstream signaling effectors across eukaryotes remains to be established. Here, we report that IRE1 and its substrate bZIP60 function as a strictly cognate enzymesubstrate pair to control viral pathogenesis in plants. Moreover, we show that the S1P/ S2P-bZIP17/bZIP28 pathway, the other known branch of UPR in plants, does not play a detectable role in virus infection, demonstrating the distinct function of the IRE1-bZIP60 pathway in plants. Furthermore, we provide evidence that bZIP60 and HAC1, products of the enzyme-substrate duet, rather than IRE1, are functionally replaceable to cope with ER stress in yeast. Taken together, we conclude that the downstream signaling of the IRE1- mediated splicing is evolutionarily conserved in yeast and plants, and that the IRE1-bZIP60 UPR pathway not only confers overlapping functions with the other UPR branch in fundamental biology but also may exert a unique role in certain biological processes such as virus-plant interactions.

59 BASIC BIOLOGICAL SCIENCES↗

Non-contact based measurement of thin film coatings using eddy current measurements

When a time varying magnetic field attempts to penetrate a conductive surface, the surface will respond to that time varying field by the generation of circular currents around the flux lines. This effect is described by Faraday’s law of induction. An eddy current based measurement system attempts to discern the power loss incurred by these circulating currents within the conductive surface. The measurement system described here uses an Agilent E 4980A LCR meter to quantify the reaction of the film to the high frequency magnetic field lines which are forced into the film. The measurement metric is the meter’s interpretation of the power dissipation caused by the measured film. The meter is setup to use the Ls/Rs inductor model, and is run at 1 Mhz to bring the losses within the film as high as possible for sensitivity.

43 PARTICLE ACCELERATORS↗

Development of magnetic field monitoring system for the MAGIS-100 experiment

The MAGIS-100 collaboration is building a long-baseline atom interferometer designed to investigate dark matter, novel forces, gravitational waves, and quantum science. A major design challenge is external, time-varying magnetic fields, the effect of which can mimic gravitational waves or expected dark matter signals. Several mitigations will be enacted, including mu-metal shielding and a suite of magnetometers. This presentation will discuss the development of a magnetic field monitoring system based on commercial magneto-inductive sensors to be installed at several points along the interferometer.

Arce, Edwin [Unlisted; Fermilab]↗

Wireless Power Transfer

Wireless Power Transfer is an innovative approach using magnetic resonance coupling of air core transformers designed for today's growing plug-in electric vehicle market. This technology can provide a convenient, safe and flexible means to charge electric vehicles under stationary and dynamic conditions. Plug-in Electric Vehicles (PEV) are burdened by the need for cable and plug charger, galvanic isolation of the on-board electronics, bulk and cost of this charger and the large energy storage system (ESS) packs needed. With a system where you have to physically plug in there are a number of occasions where the owner could very well forget to charge the vehicle. For stationary applications (like charging of a PHEV at home), ORNL's innovative wireless power transfer technology adds a convenience factor compared to actually plugging in which will mean that the vehicle will have a full charge every morning. Electric vehicle charging must be safe, compact and efficient in order to be convenient for customers. By reconfiguring the transformer and altering the resonance frequency, energy is transferred to the battery with lower energy losses and with fewer demands on the primary circuit by the rest of the transformer system. The ORNL discovery shows that sufficient power for the battery can be transferred from the primary to secondary circuits without significant energy losses if the operating frequency is set at 50% to 95% of the resonance frequency of the circuit. The electrical power is then transmitted to the chargeable battery, which is electrically coupled to the secondary circuit through the air core transformer. Some advantages include: Reduced energy losses during transfer of energy to the battery; A charge potential that is relatively unaffected by up to 25% misalignment of vehicle; and Other receiving components draw less power from the primary circuit. These advantages allow wireless power technology applications to expand at the workplace and beyond as the demand for EV rises. For vehicles that operate over a fixed route such as busses and shuttle vehicles, Wireless Power Transfer (WPT) means that a smaller battery pack can be used. In the traditional system, the battery pack is designed to accommodate the needs of the entire route or shift. With WPT the battery can be downsized because it can be charged when the vehicle stops on its route (a rental car shuttle bus, for example, can charge when it waits in the terminal and again when it waits at the rental car place. Thus the battery only needs enough charge to get to the next stop. This decrease in battery size means significant cost savings to electrify the vehicle. This technology enables efficient "opportunity charging stations" for predefined routes and planned stops reducing down time. Charging can occur in minutes. This improvement also eliminates the harmful emissions that occur in garages while buses are at idle during charging. In larger cities, dynamic charging offers an even greater impact utilizing existing infrastructure. As vehicles travel along busy freeways and interstate systems, wireless charging can occur while the vehicle is in motion. With this technology a vehicle essentially has unlimited electric range while using a relatively small battery pack. In-motion charging stations use vehicle sensors to alert the driver. Traveling at normal speeds, sensors establish in-motion charging. WPT transmit pads sequentially energize to the negotiated power level based on vehicle speed and its requested charging energy. Lower power when vehicle speed is slow and much higher power for faster moving vehicles. Vehicle to Infrastructure communications (V2I) coordinates WPT charging level according to on-board battery pack state-of-charge. V2I activates the roadway transmit pads placing them in standby mode and negotiates charging fee based on prevailing grid rate and vehicle energy demand. Dynamic charging would allow electricity to supply a very large fraction of the energy for the transportation sector and reduce greatly petroleum consumption. Previously worrisome traffic delays now provide longer periods of charge while passing over in-motion chargers. Inclement weather such as rain and snow do not affect the charging capability. At ORNL, we are working to develop the robust nature of wireless power technology to provide a convenient, safe and flexible means to charge electric vehicles under stationary and dynamic conditions.

33 ADVANCED PROPULSION SYSTEMS↗

A neural approach for the numerical modeling of two-dimensional magnetic hysteresis

This paper deals with a neural network approach to model magnetic hysteresis at macro-magnetic scale. Such approach to the problem seems promising in order to couple the numerical treatment of magnetic hysteresis to FEM numerical solvers of the Maxwell's equations in time domain, as in case of the non-linear dynamic analysis of electrical machines, and other similar devices, making possible a full computer simulation in a reasonable time. The neural system proposed consists of four inputs representing the magnetic field and the magnetic inductions components at each time step and it is trained by 2-d measurements performed on the magnetic material to be modeled. The magnetic induction B is assumed as entry point and the output of the neural system returns the predicted value of the field H at the same time step. A suitable partitioning of the neural system, described in the paper, makes the computing process rather fast. Validations with experimental tests and simulations for non-symmetric and minor loops are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Serially-Connected Compensator for Eliminating the Unbalanced Three-Phase Voltage Impact on Wind Turbine Generators

Untransposed transmission lines, unbalanced tap changer operations, and unbalanced loading in weak distribution lines can cause unbalanced-voltage conditions. The resulting unbalanced voltage at the point of interconnection affects proper gird integration and reduces the lifetime of wind turbines due to power oscillations, torque pulsations, mechanical stresses, energy losses, and uneven and overheating of the generator stator winding. This work investigates the dynamic impact of unbalanced voltage on the mechanical and electrical components of integrated Fatigue, Aerodynamics, Structures, and Turbulence (FAST) wind turbine generation systems (WTGs) of Type 1 (squirrel-cage induction generator) and Type 3 (doubly-fed induction generator). To alleviate this impact, a serially-connected compensator for a three-phase power line is proposed to balance the wind turbine-side voltage. Dynamic simulation studies are conducted in MATLAB/Simulink to compare the responses of these two types of wind turbine models under normal and unbalanced-voltage operation conditions and demonstrate the effectiveness of the proposed compensator.

17 WIND ENERGY↗

Efficient ECCD non-inductive plasma current start-up, ramp-up, and sustainment for an ST fusion reactor

The elimination of the need for an Ohmic heating solenoid may be the most impactful design driver for the realization of economical compact fusion tokamak reactor systems. However, this would require fully non-inductive start-up and current ramp-up from zero plasma current and low electron temperature of sub-keV to the full plasma current of ~10–15 MA at 20–30 keV electron temperature. To address this challenge, an efficient solenoid-free start-up and ramp-up scenario utilizing a low-field-side-launched extraordinary mode at the fundamental electron cyclotron harmonic frequency (X–I) is proposed, which has more than two orders of magnitude higher electron cyclotron current drive (ECCD) efficiency than the conventional ECCD for the sub-keV start-up regime. A time dependent model was developed to simulate the start-up scenarios. For the Spherical Tokamak Advanced Reactor (STAR) (Menard et al 2023 Next-Step Low-Aspect-Ratio Tokamak Design Studies (IAEA)), it was found that to fully non-inductively ramp-up to 15 MA, it would take about 25 MW of EC power at 170 GHz. Because of the relatively large plasma volume of STAR, radiation losses must be considered. It is important to make sure that high Z impurities are kept sufficiently low during the early current start-up phase where the temperature is sub-keV range. Since the initial current ramp up takes place at a factor of ten lower density compared to the sustained regimes, it is important to transition into a higher bootstrap fraction discharge at lower density to minimize the ECCD power requirement during the densification. For the sustainment phase an array of eight gyrotron launchers with a total of about 60 MW of fundamental O-mode was found to be sufficient to provide the required axis-peaked external current drive. High efficiencies between 19–57 kA MW –1 were found with optimal aiming, and these were resilient to small changes in aiming angles and density and temperature profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimal Litz Wire Design for High-Power Wireless Charging System

In this study, an optimized Litz wire and polyphase coil winding design is proposed for high-power wireless charging systems operating at 85 kHz frequency. Litz wire in a wireless charging system contributes to more than half of the losses of the system, making it a critical design component. Here, the Litz wire is optimized through Finite Element Analysis (FEA) considering electrical and mechanical design aspects and the design was validated through experimental tests on different Litz wires with various strand-diameters, twisting ratio, and number of strands. The proposed optimal Litz wire maximizes the system efficiency considering the tradeoff between coil resistance and mutual inductance. The optimal Litz wire shows that Litz wire constructed with the 63µm strands significantly outperform the traditionally used Litz wire with 100µm strand diameter. Additionally, the coil with optimal Litz wire design shows 60% reduction in the copper volume for the same loss, and at the same time increase the coil-to-coil efficiency by more than 2% by increasing the mutual inductance and reducing coil current. The optimized Litz wire was implemented in a 22-kW wireless charging system achieving 94.7% efficiency.

Aydin, Emrullah [ORNL]↗

Induction heaters used to heat subsurface formations

A heating system for a subsurface formation includes an elongated electrical conductor located in the subsurface formation. The electrical conductor extends between at least a first electrical contact and a second electrical contact. A ferromagnetic conductor at least partially surrounds and at least partially extends lengthwise around the electrical conductor. The electrical conductor, when energized with time-varying electrical current, induces sufficient electrical current flow in the ferromagnetic conductor such that the ferromagnetic conductor resistively heats to a temperature of at least about 300.degree. C.

47 OTHER INSTRUMENTATION↗

Evaluation of High Rotor Pole Switched Reluctance Motors to Control Condenser Fans in a Commercial Refrigeration System

A high rotor pole switched reluctance motor (HRSRM) designed by Software Motor Corporation was evaluated for use as a condenser fan motor due to its reported high motor efficiency over a broad range of speeds and added advanced control potential. The project was split into two phases; the first of which was to determine the direct energy savings due to the increased motor efficiency, the second was to leverage the additional benefits of the energy efficiency measure (EEM) to create additional energy savings. This report only discusses results from the first phase of the project. Nine 1.5hp HRSRMs were installed parallel to the same number of legacy induction motors of a supermarket commercial refrigeration system located in Lakeside, Colorado. At this site, the 1.5 hp legacy motors had historically adjusted condenser fan speed from 200-870 rpm based on outdoor air temperature and compressor discharge pressure. This type of control is known as variable head pressure control (VHPC). These nine new motors were given a signal from the legacy variable frequency drive (VFD) to match the motor speed of the legacy motors. Determination of the energy savings of the EEM was performed over a two-month period, at which time a correlation between legacy and EEM power consumption was developed based on motor speed. Annual data that had been collected from 2016-2017 (before the two-month test period) was then leveraged to predict the annual energy savings of the EEM for a complete retrofit using both VHPC and constant fan speed control. Table 1 displays the quantitative results. The EEM saved 27% of total energy consumption of the condenser fan motors for constant fan speed control, while the energy savings increased to 32% when using VHPC. This was due to the improved motor efficiency of the HRSR motor at low speeds. While the constant speed fan control kept the motors running at 870 rpm, VHPC adjusted fan speed between 200-870rpm based on the outdoor air temperature and the compressor discharge pressure. These savings are assuming a direct replacement with no additional controls. Retrofitting a constant speed fan control system with HRSRMs and switching to VHPC would provide significant energy savings looking at the condenser alone. Additional considerations of the EEM were noted during the project as well. The HRSRM system made it possible to identify and remotely shutdown an individual motor when a piece of foam locked the fan and thereby the motor. With the traditional system, a locked rotor could have caused motor damage unless a breaker or fuse was activated. Furthermore, due to vibration complaints from the installation technicians, the ramp-up time of the HRSRM had to be increased to a minute. After implementing this change no complaints for excessive vibration were recorded.

15 GEOTHERMAL ENERGY↗

Control of Output Power in Primary Side LCC and Secondary Series Tuned Wireless Power Transfer System without Secondary Side Sensors

The output power of a wireless power transfer (WPT) system varies with load and coupling factor of the inductively coupled coils. This paper presents a method to control the output power of primary side LCC and secondary side series tuned WPT system using information of primary side variables. In this approach, a secondary side control system or secondary side sensors are not needed. Detailed mathematical derivations are given to identify and justify the suitable primary side variable that accomplishes the desired purpose without the need of any secondary side communications. Simulation results presented validate the proposed scheme.

Mukherjee, Subho↗