Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENTS - DRIFT INDICATORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

An Optical Altitude Indicator for Night Landing

One of the most ingenious of the devices intended for use in night landing, especially emergency landing, is a very simple optical instrument known as the Jenkins night altitude indicator. The design and operation of this instrument, which allows a pilot to determine the altitude of the aircraft, is discussed. The author discusses various modifications and improvements that might be made to the instrument.

Warner, John A C↗

Failure detection and isolation methods for redundant gimballed inertial measurement units.

Skewed alignment of two redundant conventional inertial measuring units permits nonambiguous detection and isolation of hard and soft failures in real time by an airborne computer. Accelerometer outputs and gimbal readouts are monitored periodically, and attitude rate and velocity error vectors are computed from these data. Magnitudes of these vectors provide failure detection, and projection of these error vectors onto the coordinate axes of the two clusters permits isolation. A detailed Monte Carlo simulation of one version of the mechanization as applied to Space Shuttle boost trajectories demonstrates effectiveness down to very low levels of inertial instrument performance failures. The results indicate that worst case overall navigation performance occurs when accelerometer failures are of the order of 20 sigma and gyro failures are about 100 sigma for conventional state-of-the-art IMU instruments.

Solov, E. G.↗

Magnetic back-to-back locator

A back-to-back locator instrument includes a first portion with an array of two or more magnetic sensors, and an indicator arrangement. A second portion of the instrument includes an array of correspondingly located magnets. Each of the first and second portions includes a marking arrangement, which either allows marking of the underlying surface, or viewing of a mark on the surface for properly locating the instrument portion thereon. When the two portions are congruent or registered, the indicator arrangement gives a maximum indication of corresponding locations. In a particular use, corresponding locations on the inside and outside of a tank are identified. The indicator arrangement may include a separate indicator for each magnetic sensor. A flux concentrator may be associated with each magnetic sensor.

Phillips, Scott G.↗

An Instrument Employing a Coronal Discharge for the Determination of Droplet-Size Distribution in Clouds

A flight instrument that uses electric means for measuring the droplet-size distribution in above-freezing clouds has been devised and given preliminary evaluation in flight. An electric charge is placed on the droplets and they are separated aerodynamically according to their mass. Because the charge placed on the droplets is a. function of the droplet size, the size spectrum can 'be determined by measurement of the charge deposited on cylinders of several different sizes placed to intercept the charged droplets. An expression for the rate of charge acquisition by a water droplet in a field of coronal discharge is derived. The results obtained in flight with an instrument based on the method described indicate that continuous records of droplet-size spectrum variations in clouds can be obtained. The experimental instrument was used to evaluate the method and was not refined to the extent necessary for obtaining conclusive meteorological data. The desirable features of an instrument based on the method described are (i) The instrument can be used in clouds with temperatures above freezing; (2) the size and the shape of the cylinders do not change during the exposure time; (3) the readings are instantaneous and continuous; (4) the available sensitivity permits the study of variations in cloud structures of less than 200 feet in extent.

Brun, Rinaldo J.↗

A cryogenically cooled photofragment fluorescence instrument for measuring stratospheric water vapor

An instrument developed for high-resolution daytime measurements of water vapor in the stratosphere using the technique of photofragment fluorescence is examined. A detailed description of all aspects of the instrument, as well as the results of its first two flights, are presented. The main areas of concern were optical baffling, cryogen transfer, water vapor measurement without contamination, and a dual path absorption measurement. Results of the second flight test indicate that the problems of instrument and gondola contamination, identified in the first flight test, were solved. A signal-to-noise ratio of about 50:1 for 10 sec of averaging throughout the stratosphere is achieved, as well as an altitude resolution of better than 100 m.

Weinstock, Elliot M.↗

The Mars Phoenix Thermal Evolved-Gas Analysis: The Role of an Organic Free Blank in the Search for Organics

The Thermal Evolved-Gas Analyzer (TEGA) instrument onboard the 2007 Phoenix Lander will perform differential scanning calorimetry (DSC) and evolved-gas analysis of soil samples collected from the surface. Data from the instrument will be compared with Mars analog mineral standards, collected under TEGA Mars-like conditions to identify the volatile-bearing mineral phases [1] (e.g., Fe-oxyhydroxides, phyllosilicates, carbonates, and sulfates) found in the Martian soil. Concurrently, the instrument will be looking for indications of organics that might also be present in the soil. Organic molecules are necessary building blocks for life, although their presence in the ice or soil does not indicate life itself. The spacecraft will certainly bring organic contaminants to Mars even though numerous steps were taken to minimize contamination during the spacecraft assembly and testing. It will be essential to distinguish possible Mars organics from terrestrial contamination when TEGA instrument begins analyzing icy soils. To address the above, an Organic Free Blank (OFB) was designed, built, tested, and mounted on the Phoenix spacecraft providing a baseline for distinguishing Mars organics from terrestrial organic contamination. Our objective in this report is to describe some of the considerations used in selecting the OFB material and then report on the processing and analysis of the final candidate material

Lauer, H. V., Jr.↗

CCN data from TAMU TRACER campaign in the Houston TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow is directed through a cyclone impactor (Brechtel, Inc. Model SCC 0.732) and 0.5 LPM is directed to the CCN. To calculate particle losses, we used a two-step method. First, the measured SMPS size distributions were used to calculate particle loss through the inlet during sampling. Second, the corrected SMPS data was used to calculate the average of the total losses per scan down the CCN line. Then, the correction was applied to the CCN data. This calculation was done separately for each deployment location due to changes in the measured size distributions between locations. Particle loss from diffusion (based on Kesten, 1991 and Gormley, 1949), inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977), and cyclone impactor efficiency (based on Dirgo, 1985) were included in the loss calculation. When the SMPS was not sampling at a location (in the case of an instrument malfunction or operator error), the reported CPC data was corrected with an average of the total losses for the entire campaign at the specified deployment location (e.g., if we needed to correct Galveston data, then the average of all calculated losses at Galveston was taken). These flatline corrections were used for all data on 22/07/13, 22/07/20, 22/07/22, and the data from Galveston on 22/08/09. The supersaturation uncertainty is estimated conservatively at +/- 0.03%, where variation in the inlet temperature, pressure, and calibration technique prevents a more accurate measurement. Confidence in the reported supersaturation measurements is based on a pre-campaign calibration (following the methods from our previous work and Deng, 2014 based on Rose, 2008) in addition to inter-comparisons with the DOE for two days (22/08/18 and 22/09/01) where TAMU was co-located with AMF1. The inter-comparisons show good agreement between our instrument and the DOEs instrument on both days at all supersaturations. After the last inter-comparison on 22/09/01, there was no indication of a malfunction by our instrument through the rest of the campaign. Unfortunately, the instrument was dropped during demobilization. A post-campaign calibration was conducted, which showed a substantial departure from the pre-campaign calibration. The drop may have damaged the instrument’s ability to produce the desired supersaturations. Therefore, we do consider the data after 22/09/01 to be correct, but it should be used with caution. The CCN counter sampled for 3 minutes at each supersaturation setpoint (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%). At the end of a cycle, the instrument was set to 0.01% supersaturation for 5 minutes. The data is comprised of the last 60 seconds of each supersaturation set point (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%) to ensure the instrument stabilized and was able to reach thermal equilibrium. We removed the data during the periods where there were operational difficulties, setup, or maintenance. This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Rose et. al. Calibration and Measurement Uncertainties of a Continuous-Flow Cloud Condensation Nuclei Counter (DMT-CCNC): CCN Activation of Ammonium Sulfate and Sodium Chloride Aerosol Particles in Theory and Experiment. Atmos. Chem. Phys., 8, 1153-1179, 2008. Deng et. al. Using Raman Microspectroscopy to Determine Chemical Composition and Mixing State of Airborne Marine Aerosols over the Pacific Ocean. Aerosol Science and Technology, Vol 48, Issue 2, 2014. Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991. Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948. Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011. Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977. Dirgo et. al. Cyclone Collection Efficiency: Comparison of Experimental Results with Theoretical Predictions. Aerosol Science and Technology, 4:4, 401-415, 1985.

54 ENVIRONMENTAL SCIENCES↗

Comparison of Three Multicylinder Icing Meters and Critique of Multicylinder Method

Three multicylinder cloud meters, fundamentally similar but differing in important details, were compared in use at the Mount Washington Observatory. Determinations of liquid water content were found to agree within the limits of the probable error, but the two instruments designed by the National Advisory Committee for Aeronautics indicated larger drop sizes than did the Observatory's instrument, apparently because of spurious ice catch on the rather rough surface of the larger cylinders. Comparisons of drop-size distribution were largely indeterminate., In a critique of the method, the probable error of determination of liquid water content was found to be +/-8 percent; of drop size, +/-6 percent; and of drop-size distribution, about +/-0.7 unit of the modulus of distribution. Of the systematic errors, run-off of unfrozen water is most important, blow-off and erosion seldom being hampering. Revision of collection-efficiency computations for cylinders in clouds with distributed drop sizes was found necessary and also revision of one of the correction-factor graphs heretofore used. The assumption of constant ice density in deriving cylinder size was found to be permissible for cylinders 1 inch or more in diameter.

Howell, Wallace E.↗

Cockpit simulation study of use of flight path angle for instrument approaches

The results of a piloted simulation experiment to evaluate the effect of integrating flight path angle information into a typical transport electronic attitude director indicator display format for flight director instrument landing system approaches are presented. Three electronic display formats are evaluated during 3 deg straight-in approaches with wind shear and turbulence conditions. Flight path tracking data and pilot subjective comments are analyzed with regard to the pilot's tracking performance and workload for all three display formats.

Hanisch, B.↗

Quantification of pilot workload via instrument scan

The use of visual scanning behavior as an indicator of pilot workload is described. The relationship between level of performance on a constant piloting task under simulated IFR conditions, the skill of the pilot the level of mental workload induced by an additional verbal task imposed on the basic control task, and visual scanning behavior is investigated. An increase in fixation dwell times, especially on the primary instrument with increased mental loading is indicated. Skilled subjects 'stared' less under increased loading than did novice pilots. Sequences of instrument fixations were also examined. The percentage occurrence of the subject's most used sequences decreased with increased task difficulty for novice subjects but not for highly skilled subjects. Entropy rate (bits/sec) of the sequence of fixations was also used to quantify the scan pattern. It consistently decreased for most subjects as the four loading levels used increased.

Tole, J. R.↗

Experimental Alteration of Basalt to Support Interpretation of Remote Sensing and In Situ Meausrements from Mars

Major occurrences of hydrous alteration minerals on Mars have been found in Noachian impact craters formed in basaltic targets and detected using visible/near infrared (VNIR) spectroscopy. Until recently phyllosilicates were detected only in craters in the southern hemisphere [1, 2]. However, it has been reported that at least nine craters in the northern plains apparently excavated thick layers of lava and sediment to expose phyllosilicates [3] as well. The MER (Mars Exploration Rovers) rovers previously reported results of in situ measurement indicating the presence of alteration minerals on Mars [4,5] and it was recently reported that the Mars Curiosity rover has detected alteration phases in situ at Yellowknife Bay in Gale crater as well [6,7]. An important discovery for Mars geochronology is that the Chemistry and Mineralogy (CheMin) x-ray diffraction (XRD) instrument on Curiosity detected phyllosilicates indicating that phyllosilicate formation on Mars extended beyond the Noachian Epoch [8]. These discoveries indicate that Mars was globally altered by water in the past but does not constrain formation conditions for alteration phase occurrences, which have important implications for the evolution of the surface and the biological potential on Mars. Understanding the alteration assemblages produced by a range of conditions is vital for the interpretation of phyllosilicate spectral signatures as well as in situ measurements and to decipher the environment and evolution of early Mars. The martian surface has been intensely altered by meteorite impacts whose effects include brecciation and melting of target materials as well as the initiation of hydrothermal circulation in a hydrous target [9,10,11,12]. Impact effects may facilitate aqueous alteration of a basaltic target because the rate of silicate dissolution is a function of the degree of crystallinity, surface area, and temperature. The resultant alteration mineralogies from shocked basaltic target material are a function of the original mineral assemblage in the parent rocks, the chemistry of fluids that interacted with the rocks, and physico-chemical conditions (pH, temperatures, and pressure) during the time of mineral formation. Understanding the alteration assemblages produced by a range of conditions is vital for the interpretation of phyllosilicate spectral signatures and to decipher the environment and evolution of early Mars, and especially for identifying habitable niches in which life could be initiated and sustained. No experimentally controlled and well characterized analog materials that simulate martian shock metamorphism and alteration conditions currently exist for calibrating either remote sensing or in situ measurements of Mars. A series of experiments was initiated to assess the effects of systematic changes in the physico-chemical conditions on Mars analog materials thereby providing samples to ground-truth Mars remote sensing observations from CRISM (Compact Reconnaissance Imaging Spectrometer for Mars) and in situ measurements from Opportunity's Mössbauer and Curiosity's CHEMIN (Chemistry and Mineralogy X-Ray Diffraction/XRay Fluorescence) instruments. Results of initial experimental runs as analysed by SEM-EDS (Secondary Electron Microscopy -Energy Dispersive Spectroscopy) and X-ray Diffraction (XRD) analysis are reported here and lay the foundation for comparison with shocked and altered samples that will be characterized in the next phase of this work.

Bell, M. S.↗

A miniaturized pointing mount for Spacelab missions

A Miniaturized Pointing Mount (MPM) for Spacelab missions is defined and simulation results are described. This mount is proposed to complement the Spacelab Instrument Pointing System (IPS). It uses the same mount isolator concept as the Spacelab IPS but is much more efficient and economical for the accommodation of small shuttle payloads. The MPM is built from star tracker assemblies left over from the Apollo Telescope Mount program thereby assuring low cost and development risk. Simulation results indicate a high level of instrument stability can be expected. The short development time of the MPM would permit it to serve as a precursor to the Spacelab IPS for verifying critical new concepts such as the mount isolation and hold down mechanisms.

Fritz, C. G.↗

On state estimation for an orbiting single tether system

The effects of instrumentation accuracy and configuration on estimation error are studied for the small expendable-tether deployment system (SEDS) using a continuous-discrete extended Kalman filter (CDEKF) state estimator. A twelfth order model that incorporates the rigid body modes of the tether as well as the satellite attitude dynamics is developed. Simulation results using the model and the estimator indicate that the originally planned instrumentation package could not estimate the state vector adequately. Recommendations are made and results presented that reduce the estimation error by adding instruments and increasing selected measurement accuracies.

Greene, Michael E.↗

Single particle aerodynamic relaxation time analyzer

An instrument employing a laser Doppler velocimeter and a microphone to measure the phase lag of the motion of aerosol particulates relative to the motion of the fluid medium within an acoustic field is described. The relaxation times and aerodynamic diameters of the particles or droplets are determined in real time from the measured values of phase lag; thus, the size analysis is independent of the electrostatic charges and refractive indices of the particulates. The instrument is suitable for analyzing the aerodynamic size spectrum of atmospheric particulate pollutants with aerodynamic diameters ranging from 0.1 to 10.0 microns.

Mazumder, M. K.↗

Investigation of techniques for correcting ERTS data for solar and atmospheric effects

The author has identified the following significant results. A technique is described by which an ERTS investigator can obtain absolute target reflectances by correcting spacecraft radiance measurements for variable target irradiance, atmospheric attenuation, and atmospheric backscatter. A simple measuring instrument and the necessary atmospheric measurements are discussed, and examples demonstrate the nature and magnitude of the atmospheric corrections. Preliminary results indicate that the radiant power measuring instrument will provide one technique for calibrating ERTS-1 data. The March 27, 1973 mission was significant in the NASA C-130 aircraft and ERTS-1 simultaneously passed over the test sites where RPMI's were being deployed to measure solar and atmospheric parameters and site reflectance.

Rogers, R. H.↗

Report of the Instrumentation Frontier Working Group for Snowmass 2021

Detector instrumentation is at the heart of scientific discoveries. Cutting edge technologies enable US particle physics to play a leading role worldwide. This report summarizes the current status of instrumentation for High Energy Physics (HEP), the challenges and needs of future experiments and indicates high priority research areas. The Snowmass Instrumentation Frontier studies detector technologies and Research and Development (R&D) needed for future experiments in collider physics, neutrino physics, rare and precision physics and at the cosmic frontier. It is divided into more or less diagonal areas with some overlap among a few of them. We lay out five high-level key messages that are geared towards ensuring the health and competitiveness of the US detector instrumentation community, and thus the entire particle physics landscape.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Report of the Instrumentation Frontier Working Group for Snowmass 2021

Detector instrumentation is at the heart of scientific discoveries. Cutting edge technologies enable US particle physics to play a leading role worldwide. This report summarizes the current status of instrumentation for High Energy Physics (HEP), the challenges and needs of future experiments and indicates high priority research areas. The Snowmass Instrumentation Frontier studies detector technologies and Research and Development (R&D) needed for future experiments in collider physics, neutrino physics, rare and precision physics and at the cosmic frontier. It is divided into more or less diagonal areas with some overlap among a few of them. We lay out five high-level key messages that are geared towards ensuring the health and competitiveness of the US detector instrumentation community, and thus the entire particle physics landscape.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intercomparison of Satellite Dust Retrieval Products over the West African Sahara During the Fennec Campaign in June 2011

Dust retrievals over the Sahara Desert during June 2011 from the IASI, MISR, MODIS, and SEVIRI satellite instruments are compared against each other in order to understand the strengths and weaknesses of each retrieval approach. Particular attention is paid to the effects of meteorological conditions, land surface properties, and the magnitude of the dust loading. The period of study corresponds to the time of the first Fennec intensive measurement campaign, which provides new ground-based and aircraft measurements of the dust characteristics and loading. Validation using ground-based AERONET sunphotometer data indicate that of the satellite instruments, SEVIRI is most able to retrieve dust during optically thick dust events, whereas IASI and MODIS perform better at low dust loadings. This may significantly affect observations of dust emission and the mean dust climatology. MISR and MODIS are least sensitive to variations in meteorological conditions, while SEVIRI tends to overestimate the aerosol optical depth (AOD) under moist conditions (with a bias against AERONET of 0.31), especially at low dust loadings where the AOD<1. Further comparisons are made with airborne LIDAR measurements taken during the Fennec campaign, which provide further evidence for the inferences made from the AERONET comparisons. The effect of surface properties on the retrievals is also investigated. Over elevated surfaces IASI retrieves AODs which are most consistent with AERONET observations, while the AODs retrieved by MODIS tend to be biased low. In contrast, over the least emissive surfaces IASI significantly underestimates the AOD (with a bias of -0.41), while MISR and SEVIRI show closest agreement.

Fennec Campaign↗