Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENTS - PROTRACTORS - ZAHM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

On the instrument-dependent appearance of ion dissociation events in atom probe tomography mass spectra

The successful application of atom probe tomography (APT) relies on the accurate interpretation of the mass spectrum (i.e. m/z histogram) from a sample. Some materials yield mass spectra that are amenable to a straightforward peak assignment/ranging, however, there are many materials that produce mass spectra with features that defy simple interpretation. One such example is Ga 2 O 3 which yields mass spectra containing several broad and difficult to interpret features. Herein, we study the GaO 2+ → O 1+ + Ga 1+ dissociation and we explain how this dissociation process gives rise to broad and previously unassigned features in the mass spectrum. Trajectory simulations are performed for the dissociation reaction utilizing realistic electrostatic models and compared to experiments using commercially available straight flight and reflectron based local electrode (LE) APT instruments. It is shown that the appearance of these features is strongly dependent on the specific design of the time-of-flight (ToF) mass analyzer. Additionally, we explore how various experimental parameters can affect the appearance of the dissociation process in the one-dimensional (1D) mass spectrum and in the two-dimensional (2D) correlation histogram. While the focus of this work is on a particular dissociation process related to Ga 2 O 3 , the understanding gained in the course of these simulations and experiments should be applicable to the interpretation of dissociation processes in other materials.

47 OTHER INSTRUMENTATION↗

Co-orchestration of multiple instruments to uncover structure–property relationships in combinatorial libraries

The rapid growth of automated and autonomous instrumentation brings forth opportunities for the co-orchestration of multimodal tools that are equipped with multiple sequential detection methods or several characterization techniques to explore identical samples. This is exemplified by combinatorial libraries that can be explored in multiple locations via multiple tools simultaneously or downstream characterization in automated synthesis systems. In co-orchestration approaches, information gained in one modality should accelerate the discovery of other modalities. Correspondingly, an orchestrating agent should select the measurement modality based on the anticipated knowledge gain and measurement cost. Herein, we propose and implement a co-orchestration approach for conducting measurements with complex observables, such as spectra or images. The method relies on combining dimensionality reduction by variational autoencoders with representation learning for control over the latent space structure and integration into an iterative workflow via multi-task Gaussian Processes (GPs). This approach further allows for the native incorporation of the system's physics via a probabilistic model as a mean function of the GPs. We illustrate this method for different modes of piezoresponse force microscopy and micro-Raman spectroscopy on a combinatorial Sm-BiFeO3 library. However, the proposed framework is general and can be extended to multiple measurement modalities and arbitrary dimensionality of the measured signals.

47 OTHER INSTRUMENTATION↗

New capability for indirect neutron capture measurements: The DICER instrument at LANSCE

The Device for Indirect Capture on Radionuclides (DICER) implements a new indirect technique for (n,γ) studies in which the neutron capture rate is determined from analysis of resonance neutron transmission data. The DICER instrument and associated radionuclide production at the Isotope Production Facility (IPF), both at the Los Alamos Neutron Science Center (LANSCE), as well radioactive sample fabrication, have been under development in the last few years. First measurements on a radioactive sample ( 88 Zr, t ½ =83.4 days), which was recently reported to have an extremely large thermal neutron capture cross section and resonance integral, are planned for the winter of 2021. A performance overview, brief details on the 88Zr fabrication and proof of good operation results will be presented.

47 OTHER INSTRUMENTATION↗

DICER: A new instrument at LANSCE to constrain neutron capture rates on radionuclides

With very few exceptions, direct measurements of neutron capture rates on radionuclides have not been possible. A number of indirect methods have been pursued such as the surrogate method, the γ-ray strength function method, the Oslo method and the β-Oslo method. Substantial effort has been devoted to quantify the usually large systematic errors that accompany the results from these techniques. A new instrument has been developed at the Los Alamos Neutron Science Center (LANSCE) to provide more accurate data on several radionuclides relevant to nuclear criticality safety, radiochemical diagnostics, astrophysics, nuclear forensics and nuclear security, by measuring the transmission of neutrons through radioactive samples and studying resonance properties. The Device for Indirect Capture on Radionuclides (DICER) and associated radionuclide production at the Isotope Production Facility (IPF), both at LANSCE, as well radioactive sample fabrication, have been under development the last few years. A description of the new apparatus, data on a few mid-weight stable isotopes and efforts on radionuclide measurements will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High energy electron diffraction instrument with tunable camera length

Ultrafast electron diffraction (UED) stands as a powerful technique for real-time observation of structural dynamics at the atomic level. In recent years, the use of MeV electrons from radio frequency guns has been widely adopted to take advantage of the relativistic suppression of the space charge effects that otherwise limit the temporal resolution of the technique. Nevertheless, there is not a clear choice for the optimal energy for a UED instrument. Scaling to beam energies higher than a few MeV does pose significant technical challenges, mainly related to the inherent increase in diffraction camera length associated with the smaller Bragg angles. In this study, we report a solution by using a compact post-sample magnetic optical system to magnify the diffraction pattern from a crystal Au sample illuminated by an 8.2 MeV electron beam. Our method employs, as one of the lenses of the optical system, a triplet of compact, high field gradients (>500 T/m), small-gap (3.5 mm) Halbach permanent magnet quadrupoles. Shifting the relative position of the quadrupoles, we demonstrate tuning the magnification by more than a factor of two, a 6× improvement in camera length, and reciprocal space resolution better than 0.1 Å –1 in agreement with beam transport simulations.

47 OTHER INSTRUMENTATION↗

Application of an energy-dependent instrument response function to analysis of nTOF data from cryogenic DT experiments

Neutron time-of-flight (nTOF) detectors are used to diagnose the conditions present in inertial confinement fusion (ICF) experiments and basic laboratory physics experiments performed on an ICF platform. The instrument response function (IRF) of these detectors is constructed by convolution of two components: an x-ray IRF and a neutron interaction response. The shape of the neutron interaction response varies with incident neutron energy, changing the shape of the total IRF. Analyses of nTOF data that span a broad range of energies must account for this energy-dependence in order to accurately infer plasma parameters and nuclear properties in ICF experiments. This work briefly reviews a matrix multiplication approach to convolution which allows for an energy-dependent change in the shape of the IRF. This method is applied to synthetic data resembling symmetric cryogenic DT implosions to examine the effect of the energy-dependent IRF on the inferred areal density. Here, results of forward fits that infer ion temperatures and areal densities from nTOF data collected during cryogenic DT experiments on OMEGA are also discussed.

47 OTHER INSTRUMENTATION↗

An instrument for in situ characterization of powder spreading dynamics in powder-bed-based additive manufacturing processes

In powder-bed-based metal additive manufacturing (AM), the visualization and analysis of the powder spreading process are critical for understanding the powder spreading dynamics and mechanisms. Unfortunately, the high spreading speeds, the small size of the powder, and the opacity of the materials present a great challenge for directly observing the powder spreading behavior. In this study, we report a compact and flexible powder spreading system for in situ characterization of the dynamics of the powders during the spreading process by high-speed x-ray imaging. The system enables the tracing of individual powder movement within the narrow gap between the recoater and the substrate at variable spreading speeds from 17 to 322 mm/s. The instrument and method reported here provide a powerful tool for studying powder spreading physics in AM processes and for investigating the physics of granular material flow behavior in a confined environment.

47 OTHER INSTRUMENTATION↗

The QICK (Quantum Instrumentation Control Kit): Readout and control for qubits and detectors

We introduce a Xilinx RF System-on-Chip (RFSoC)-based qubit controller (called the Quantum Instrumentation Control Kit, or QICK for short), which supports the direct synthesis of control pulses with carrier frequencies of up to 6 GHz. The QICK can control multiple qubits or other quantum devices. The QICK consists of a digital board hosting an RFSoC field-programmable gate array, custom firmware, and software and an optional companion custom-designed analog front-end board. We characterize the analog performance of the system as well as its digital latency, important for quantum error correction and feedback protocols. We benchmark the controller by performing standard characterizations of a transmon qubit. We achieve an average gate fidelity of ℱ avg =99.93%. All of the schematics, firmware, and software are open-source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of mosaic crystal instrument functions on x-ray Thomson scattering diagnostics

Mosaic crystals, with their high integrated reflectivities, are widely employed in spectrometers used to diagnose high energy density systems. X-ray Thomson scattering (XRTS) has emerged as a powerful diagnostic tool of these systems, providing in principle direct access to important properties such as the temperature via detailed balance. However, the measured XRTS spectrum is broadened by the spectrometer instrument function (IF), and without careful consideration of the IF one risks misdiagnosing system conditions. Here, we consider in detail the IF of 40 and 100 μm mosaic Highly Annealed Pyrolytic Graphite crystals, and how the broadening varies across the spectrometer in an energy range of 6.7–8.6 keV. Notably, we find a strong asymmetry in the shape of the IF toward higher energies. As an example, we consider the effect of the asymmetry in the IF on the temperature inferred via XRTS for simulated 80 eV CH plasmas and find that the temperature can be overestimated if an approximate symmetric IF is used. We, therefore, expect a detailed consideration of the full IF will have an important impact on system properties inferred via XRTS in both forward modeling and model-free approaches.

47 OTHER INSTRUMENTATION↗

Calibration and characterization of the line-VISAR diagnostic at the HED-HIBEF instrument at the European XFEL

In dynamic-compression experiments, the line-imaging Velocity Interferometer System for Any Reflector (VISAR) is a well-established diagnostic used to probe the velocity history, including wave profiles derived from dynamically compressed interfaces and wavefronts, depending on material optical properties. Knowledge of the velocity history allows for the determination of the pressure achieved during compression. Such a VISAR analysis is often based on Fourier transform techniques and assumes that the recorded interferograms are free from image distortions. In this paper, we describe the VISAR diagnostic installed at the HED-HIBEF instrument located at the European XFEL along with its calibration and characterization. It comprises a two-color (532, 1064 nm), three-arm (with three velocity sensitivities) line imaging system. We provide a procedure to correct VISAR images for geometric distortions and evaluate the performance of the system using Fourier analysis. We finally discuss the spatial and temporal calibrations of the diagnostic. As an example, we compare the pressure extracted from the VISAR analysis of shock-compressed polyimide and silicon.

47 OTHER INSTRUMENTATION↗

A Redundancy-Guided Approach for the Hazard Analysis of Digital Instrumentation and Control Systems in Advanced Nuclear Power Plants

We report digital instrumentation and control (I&C) upgrades are a vital research area for the nuclear industry. Despite their performance benefits, deployment of digital I&C in nuclear power plants (NPPs) has been limited. Digital I&C systems exhibit complex failure modes including common cause failures (CCFs), which can be difficult to identify. This paper describes the development of a redundancy-guided application of the Systems-Theoretic Process Analysis and fault tree analysis for the hazard analysis of digital I&C in advanced NPPs. The resulting Redundancy-Guided Systems-Theoretic Hazard Analysis (RESHA) is applied for the case study of a representative state-of-the-art digital reactor trip system. The analysis qualitatively and systematically identifies the most critical CCFs and other hazards of digital I&C systems. Ultimately, the RESHA can help researchers make informed decisions for how, and to what degree, defensive measures such as redundancy, diversity, and defense in depth can be used to mitigate or eliminate the potential hazards of digital I&C systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

StarDICE III: characterization of the photometric instrument with a collimated beam projector

The measurement of Type Ia supernovae magnitudes provides cosmological distances, which constrain dark energy parameters. Current and upcoming large photometric surveys require improved photometric calibration precision to reduce systematic uncertainties in cosmological constraints. The StarDICE experiment aims to establish accurate broad-band flux references for these surveys, targeting sub-percent precision in magnitude measurements. Achieving this requires precise filter bandpass measurements for both StarDICE and survey instruments with sub-nanometre accuracy. To this end, we developed the Collimated Beam Projector (CBP), an optical device for calibrating the throughput of astronomical telescopes and their filters. The CBP uses a tunable laser source and a reversed telescope to emit a parallel monochromatic light beam, continuously monitored in flux and wavelength. The CBP output flux is measured with a large-area photodiode calibrated relative to a NIST photodiode. Using CBP measurements, we derive the StarDICE telescope throughput and filter transmissions, anchoring them to NIST’s absolute calibration. After analysing systematic uncertainties, we achieved sub-nanometre accuracy for filter central wavelengths, measured filter transmission with ~0.5 per cent precision per 1 nm bin, and detected out-of-band leakages at a relative level of 10 –4 ⁠. Furthermore, we synthesized equivalent transmission for full pupil illumination from four sampled positions in the StarDICE telescope mirror, with ~0.2 nm accuracy for central wavelengths and 7 mmag for broad-band fluxes. This demonstrates our ability to characterize telescope throughput down to the millimagnitude, paving the way for future developments, such as the Rubin-CBP for measuring the LSST at Vera Rubin Observatory, and a portable CBP version for in-situ transmission monitoring.

Calibration↗

Experimental advances with the QICK (Quantum Instrumentation Control Kit) for superconducting quantum hardware

The Quantum Instrumentation Control Kit (QICK) is a standalone open-source qubit controller that was first introduced in 2022. In this follow-up work, we present recent upgrades to the QICK and the experimental use cases they uniquely enabled for superconducting qubit systems. These include multiplexed signal generation and readout, mixer-free readout, predistorted fast flux pulses, and phase-coherent pulses for parametric operations, including high-fidelity parametric entangling gates. We explain in detail how the QICK was used to enable these experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extending synchrotron SAXS instrument ranges through addition of a portable, inexpensive USAXS module with vertical rotation axes

Ultra-SAXS can enhance the capabilities of existing synchrotron SAXS/WAXS beamlines. A compact ultra-SAXS module has been developed, which extends the measurable q -range with 0.0015 ≤ q (nm −1 ) ≤ 0.2, allowing structural dimensions in the range 30 ≤ D (nm) ≤ 4000 to be probed in addition to the range covered by a high-end SAXS/WAXS instrument. By shifting the module components in and out on their respective motor stages, SAXS/WAXS measurements can be easily and rapidly interleaved with USAXS measurements. The use of vertical crystal rotation axes (horizontal diffraction) greatly simplifies the construction, at minimal cost to efficiency. In this paper, the design considerations, realization and synchrotron findings are presented. Measurements of silica spheres, an alumina membrane, and a porous carbon catalyst are provided as application examples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Instrumentation for Assessing DC Electrical Distribution Systems in Buildings

Direct current (DC) distribution systems is emerging as a favorable option over alternating current in buildings due to its energy and non-energy benefits (e.g., efficiency, resilience, safety). However, limited guidelines exist to evaluate the DC electrical distribution infrastructure. This paper aims to fill that gap by detailing our experience with metering a building-level electrical DC distribution system. Our case study is a DC microgrid at the Direct Energy Partners Research & Development facility located in Charlotte, North Carolina. This paper presents our approach, technical challenges, and lessons learned with DC metering and instrumentation.

buildings↗

Entangled Photon Pair Source Demonstrator Using the Quantum Instrumentation Control Kit System

Here, we report the first demonstration of using the Quantum Instrumentation and Control Kit (QICK) system on RFSoC-FPGA technology to drive the electro-optic intensity modulator that generate time-bin entangled photon pairs and to detect the photon signals. With the QICK system, we achieve high levels of performance metrics including coincidence-to-accidental ratio exceeding 150, and entanglement visibility exceeding 95%, consistent with performance metrics achieved using conventional waveform generators. We also demonstrate simultaneous detector readout using the digitization functional of QICK, achieving internal system synchronization time resolution of 3.2 ps. The work reported in this paper represents an explicit demonstration of the feasibility for replacing commercial waveform generators and time taggers with RFSoC-FPGA technology in the operation of a quantum network, representing a cost reduction of more than an order of magnitude.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗