Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION PROBES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Stability of nanoclusters in 14YWT oxide dispersion strengthened steel under heavy ion-irradiation by atom probe tomography

14YWT oxide dispersion strengthened (ODS) ferritic steel was irradiated with of 5 MeV Ni2+ ions, at 300 C, 450 C, and 600 C to a damage level of 100 dpa. The stability of Ti–Y–O nanoclusters was investigated by applying atom probe tomography (APT) in voltage mode, of the samples before and after irradiations. The average size and number density of the nanoclusters was determined using the maximum separation method. These techniques allowed for the imaging of nanoclusters to sizes well below the resolution limit of conventional transmission electron microscopy techniques. The most significant changes were observed for samples irradiated at 300 C where the size (average Guinier radius) and number density of nanoclusters were observed to decrease from 1.1 nm to 0.8 nm and 12 1023 to 3.6 1023, respectively. In this study, the nanoclusters are more stable at higher temperature.

99 GENERAL AND MISCELLANEOUS↗

Chapter 13: Time-of-Flight Secondary-Ion Mass Spectrometry and Atom Probe Tomography

Time-of-flight secondary-ion mass spectrometry (TOF-SIMS) and atom probe tomography (APT) have many similarities. Both detect the chemical makeup of a solid material at ppm or better sensitivity, while retaining the spatial location information from the signal. Both use a similar principle to measure a signal associated with a given charged secondary ion—the flight time it takes a secondary ion to reach the detector after it is generated. Both are destructive techniques—albeit destructive of very small volumes—because the signal measured is generated by the removal of material from the sample itself. Importantly, both techniques require ultra-high vacuum (UHV) to ensure that the secondary ions, once generated, can reach the detector without collision with other atoms in the gas phase. In the case of TOF-SIMS, the samples can vary from several mm to several inches in size, whereas for APT, the samples are cones several hundred microns in size that are prepared in a special manner (covered in detail later in the chapter). We will discuss the basic fundamentals of each technique and cover several examples of the technique applied to photovoltaic materials, which should give a good idea of the types of information one can gain from TOF-SIMS and APT and how they are complementary as they both operate at different length scales: at the hundreds of microns to hundreds of nanometer scale for TOF-SIMS and at the nanometer to a few angstroms scale for APT.

41 EE - Solar Energy Technologies Office (EE-4S)↗

CAMP@FLASH: an end-station for imaging, electron- and ion-spectroscopy, and pump–probe experiments at the FLASH free-electron laser

The non-monochromatic beamline BL1 at the FLASH free-electron laser facility at DESY was upgraded with new transport and focusing optics, and a new permanent end-station, CAMP, was installed. This multi-purpose instrument is optimized for electron- and ion-spectroscopy, imaging and pump–probe experiments at free-electron lasers. It can be equipped with various electron- and ion-spectrometers, along with large-area single-photon-counting pnCCD X-ray detectors, thus enabling a wide range of experiments from atomic, molecular, and cluster physics to material and energy science, chemistry and biology. Here, an overview of the layout, the beam transport and focusing capabilities, and the experimental possibilities of this new end-station are presented, as well as results from its commissioning.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scanning Kelvin Probe Microscopy Reveals That Ion Motion Varies with Dimensionality in 2D Halide Perovskites

We study ion migration in 2D lead halide perovskites of varying dimensionality using scanning Kelvin probe microscopy (SKPM). We perform potentiometry on micrometer-scale lateral junctions in the absence of injected charge, and we compare how ion motion varies between prototypical two-dimensional n-butylammonium lead iodide perovskites (BA 2 PbI 4 , n = 1), and methylammonium-incorporated quasi-2D perovskites (BA 2 MA 3 Pb 4 I 13 , ~ < n > = 4) under the effects of illumination and temperature. We attribute the observed slow dynamics to relaxation of the bias-induced ionic charge distributions at different temperatures, and we extract the activation energies associated with the ionic motion in each case. Lastly, we propose an explanation for these phenomena by hypothesizing that ion motion in purely-2D BA 2 PbI 4 perovskite films is dominated by paired halide and halide vacancy, whereas for quasi-2D BA 2 MA 3 Pb 4 I 13 perovskites, the ion motion is a combination of both halide and methylammonium (vacancy) migration. These data show that dimensionality in these systems plays a critical role in ion dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Customized atomic force microscopy probe by focused-ion-beam-assisted tip transfer

We present a technique for transferring separately fabricated tips onto tipless atomic force microscopy (AFM) cantilevers, performed using focused ion beam-assisted nanomanipulation. This method addresses the need in scanning probe microscopy for certain tip geometries that cannot be achieved by conventional lithography. For example, in probing complex layered materials or tall biological cells using AFM, a tall tip with a high-aspect-ratio is required to avoid artifacts caused by collisions of the tip's sides with the material being probed. We show experimentally that tall (18 μm) cantilever tips fabricated by this approach reduce squeeze-film damping, which fits predictions from hydrodynamic theory, and results in an increased quality factor (Q) of the fundamental flexural mode. We demonstrate that a customized tip's well-defined geometry, tall tip height, and aspect ratio enable improved measurement of elastic moduli by allowing access to low-laying portions of tall cells (T lymphocytes). This technique can be generally used to attach tips to any micromechanical device when conventional lithography of tips cannot be accomplished.

36 MATERIALS SCIENCE↗

Electron density measurement of cesium seeded negative ion source by surface wave probe

Electron density measurements of a large-scaled negative ion source were carried out with a surface wave probe. By comparison of the electron densities determined with the surface wave probe and a Langmuir probe, it was confirmed that the surface wave probe is highly available for diagnostic of the electron density in H{sup -} ion sources. In addition, it was found that the ratio of the electron density to the H{sup -} ion density dramatically decreases with increase of a bias voltage and the H{sup -} ions become dominant negative particles at the bias voltage of more than 6 V.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bunker probe: A plasma potential probe almost insensitive to its orientation with the magnetic field

Due to their ability to suppress a large part of the electron current and thus measuring directly the plasma potential, ion sensitive probes have begun to be widely tested and used in fusion devices. For these probes to work, almost perfect alignment with the total magnetic field is necessary. This condition cannot always be fulfilled due to the curvature of magnetic fields, complex magnetic structure, or magnetic field reconnection. In this perspective, we have developed a plasma potential probe (named Bunker probe) based on the principle of the ion sensitive probe but almost insensitive to its orientation with the total magnetic field. Therefore it can be used to measure the plasma potential inside fusion devices, especially in regions with complex magnetic field topology. Experimental results are presented and compared with Ball-Pen probe measurements taken under identical conditions. We have observed that the floating potential of the Bunker probe is indeed little affected by its orientation with the magnetic field for angles ranging from 90° to 30°, in contrast to the Ball-Pen probe whose floating potential decreases towards that of a Langmuir probe if not properly aligned with the magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combining microscopic and macroscopic probes to untangle the single-ion anisotropy and exchange energies in an S = 1 quantum antiferromagnet [Combining micro- and macroscopic probes to untangle single-ion and spatial exchange anisotropies in a S = 1 quantum antiferromagnet]

The magnetic ground state of the quasi-one-dimensional spin-1 antiferromagnetic chain is sensitive to the relative sizes of the single-ion anisotropy (D) and the intrachain (J) and interchain (J') exchange interactions. The ratios D/J and J' /J dictate the material's placement in one of three competing phases: a Haldane gapped phase, a quantum paramagnet, and an XY-ordered state, with a quantum critical point at their junction. We have identified [Ni(HF 2 )(pyz) 2 ] SbF 6 , where pyz = pyrazine, as a rare candidate in which this behavior can be explored in detail. Combining neutron scattering (elastic and inelastic) in applied magnetic fields of up to 10 tesla and magnetization measurements in fields of up to 60 tesla with numerical modeling of experimental observables, we are able to obtain accurate values of all of the parameters of the Hamiltonian [D = 13.3(1) K, J = 10.4(3) K, and J' = 1.4(2) K], despite the polycrystalline nature of the sample. Density-functional theory calculations result in similar couplings (J = 9.2 K, J' = 1.8 K) and predict that the majority of the total spin population resides on the Ni(II) ion, while the remaining spin density is delocalized over both ligand types. Finally, the general procedures outlined in this paper permit phase boundaries and quantum-critical points to be explored in anisotropic systems for which single crystals are as yet unavailable.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Is the Collecting Surface of a Flat One-Sided Probe Constant when Measuring the Ion Distribution Function?

The correctness of the known plane single-ended probe method for measuring the anisotropic ion distribution functions in a gas-discharge plasma has been considered. Analysis has been performed for positive probe potentials relative to the plasma with magnitudes on the order of the mean ion energy, which as a rule is much lower than the mean electron energy. We have analyzed the dependence of the collection surface area of a plane probe on its potential in this range. The structure of the near-probe layer has been determined for an isotropic electron distribution function of the Maxwellian or Druvestein type and an anisotropic ion distribution function. These results are used to derive analytic relations for the correction to the second derivative of the probe current with respect to the plane probe potential. It has been shown that, when the ion distribution function is measured in a wide range of conditions in the gas-discharge plasma, when the approximation of a collisionless probe layer is applicable, and the probe does not perturb the plasma, the dependence of the collection surface area of the probe on the potential can be disregarded in this range.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correlated transmission electron microscopy and atom probe tomography characterization of ion irradiated Ni-based alloy Hastelloy N

Ion irradiation of Hastelloy N was conducted to better characterize the effects of irradiation on Hastelloy N using modern tools compared to studies done in the 1950s. The 2 MeV Ni + ion irradiation at 600 °C of Hastelloy N has been investigated using atom probe tomography, transmission electron microscopy and energy dispersive spectroscopy. Irradiation is found to promote formation of nanoscale M 2 C carbides over the thermodynamically favored M 6 C. Segregation of Si to dislocation loops and grain boundaries was also evident and may have assisted in formation of M 2 C. These microstructural changes result in a 20 % hardness increase caused by irradiation alone. These observations are useful in the design of new materials better suited for the harsh environment of a molten salt reactor.

Atom probe tomography↗

Structure evolution of magnetron sputtered TiO{sub 2} thin films

The structure evolution of TiO{sub 2} thin films deposited by rf and dc magnetron sputtering onto nonintentionally heated, floating, glass and Si (100) substrates was investigated. As the total pressure was varied from 0.15 to 4.0 Pa, corresponding to the pressure-distance product values from 10.5 to 280 Pa mm, rutile, anatase, and a mixture thereof were deposited. The pressure-distance induced changes in ion energy were quantified by probing the ion energy distribution functions. The ion energy during synthesis was additionally varied by applying a substrate bias potential ranging from floating to -100 V revealing a similar phase formation characteristic. While the structure evolution of the TiO{sub 2} thin films reported in the literature exhibits a rather complex dependence on the process parameters, a simple correlation between the structure evolution and the ratio between the ion energy flux and the deposition flux was identified here. Phase pure anatase films were grown below 540 eV/Ti atom and phase pure rutile films were grown above 1000 eV/Ti atom. The here presented data suggest that the ratio between the ion energy flux and the deposition flux ratio defines the phase formation of TiO{sub 2} thin films during magnetron sputtering.

36 MATERIALS SCIENCE↗

$$\Lambda $$ polarization in very high energy heavy ion collisions as a probe of the quark–gluon plasma formation and properties

Abstract We have studied the spin polarization of $$\Lambda $$ Λ hyperons in heavy ion collisions at center-of-mass energies $$\sqrt{s_\textrm{NN}}= 200$$ s NN = 200 GeV and $$\sqrt{s_\textrm{NN}}= 5.02$$ s NN = 5.02 TeV carried out at RHIC and LHC colliders. We have calculated the mean spin vector at local thermodynamic equilibrium, including all known first-order terms in the gradients of the thermo-hydrodynamic fields, assuming that the hadronization hypersurface has a uniform temperature. We have also included the feed-down contributions to the polarization of $$\Lambda $$ Λ stemming from the decays of polarized $$\Sigma ^*$$ Σ ∗ and $$\Sigma ^0$$ Σ 0 hyperons. The obtained results are in good agreement with the data. In general, the component of the spin vector along the global angular momentum, orthogonal to the reaction plane, shows strong sensitivity to the initial longitudinal flow velocity. Furthermore, the longitudinal component of the spin vector turns out to be very sensitive to the bulk viscosity of the plasma at the highest LHC energy. Therefore, the azimuthal dependence of spin polarization can effectively constrain the initial hydrodynamic conditions and the transport coefficients of the quark gluon plasma.

Physics↗

Free spectator nucleons in ultracentral relativistic heavy-ion collisions as a probe of neutron skin

Besides the yield ratio of free spectator neutrons produced in ultracentral 96 Zr + 96 Zr to 96 Ru + 96 Ru collisions, we propose that the yield ratio N n /N p of free spectator neutrons to protons in a single collision system at the BNL Relativistic Heavy Ion Collider or the CERN Large Hadron Collider can be a more sensitive probe of the neutron-skin thickness Δrnp and the slope parameter L of the symmetry energy. Here, the idea is demonstrated based on the proton and neutron density distributions of colliding nuclei obtained from Skyrme-Hartree-Fock-Bogolyubov calculations, and on a Glauber model that provides information of spectator matter. The final spectator particles are produced from direct emission, clusterization by a minimum spanning tree algorithm or a Wigner function approach, and deexcitation of heavy clusters by gemini. A larger Δr np associated with a larger L value increases the isospin asymmetry of spectator matter and thus leads to a larger N n /N p , especially in ultracentral collisions where the multiplicity of free nucleons are free from the uncertainties of cluster formation and deexcitation. We have further shown that the double ratio of N n /N p in isobaric collision systems or in collisions by isotopes helps to cancel the detecting efficiency for protons. Effects from nuclear deformation and electromagnetic excitation are studied, and they are found to be subdominant compared to the expected sensitivity to Δr np .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Atom probe tomography characterization of ion and neutron irradiated Alloy 800H

Alloy 800H is a high temperature and creep resistant alloy, and is considered as a candidate alloy for use in Generation IV nuclear reactor systems. To clarify the alloy's behavior under irradiation, samples were subjected to single ion irradiations up to 20 dpa at 440°C, a dual ion/He irradiation to 17 dpa at 460°C, and a neutron irradiation to 17 dpa at 385°C. The irradiated microstructures were characterized using atom probe tomography to complement previously published transmission electron microscopy studies. Additionally, after single ion irradiation, sparse fine Al and Ti clusters were observed after 1dpa, while high number densities of nanoscale Ni-Al-Ti clusters, Cr-Ti rich carbides, and Si-decorated dislocation loops developed after 10 and 20 dpa. The microstructure formed during single ion irradiation exhibited a strong depth dependence. No significant differences were observed between the single and dual ion irradiations. While Ni-Al-Ti clusters, Cr-Ti rich carbides, and Si-decorated dislocation loops were also observed after neutron irradiation, the neutron-irradiated microstructure differed from those found in the ion-irradiated samples.

36 MATERIALS SCIENCE↗