Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Prompt Detection of Fast Optical Bursts with the Vera C. Rubin Observatory

Abstract The transient optical sky has remained largely unexplored on very short timescales. While there have been some experiments searching for optical transients from minutes to years, none have had the capability to distinguish millisecond fast optical bursts (FOBs). Such very fast transients could be the optical counterparts of fast radio bursts, the prompt emission from γ -ray bursts, or other previously unknown phenomena. Here, we investigate a novel approach to the serendipitous detection of FOBs, which relies on searching for anomalous spatial images. In particular, due to their short duration, the seeing-distorted images of FOBs should look characteristically different than those of steady sources in a standard optical exposure of finite duration. We apply this idea to simulated observations with the Vera C. Rubin Observatory, produced by tracing individual photons through a turbulent atmosphere, and down through the optics and camera of the Rubin telescope. We compare these simulated images to steady-source star simulations in 15 s integrations, the nominal Rubin exposure time. We report the classification accuracy results of a neural network classifier for distinguishing FOBs from steady sources. From this classifier, we derive constraints in duration–intensity parameter space for unambiguously identifying FOBs in Rubin observations. We conclude with estimates of the total number of detections of FOB counterparts to FRBs expected during the 10 yr Rubin Legacy Survey of Space and Time.

79 ASTRONOMY AND ASTROPHYSICS↗

Terrain Relative Navigation in a Lunar Landing Scenario Using autoNGC

NASA Goddard Space Flight Center is developing Autonomous Navigation Guidance and Control (autoNGC) as a flight software system for future onboard use for missions in a variety of orbital regimes, including cislunar space and beyond. This paper describes processor-in-the-loop (PIL) testing using a lunar landing scenario with terrain relative navigation (TRN) and weak-signal GPS. We give an overview of the autoNGC project and describe preliminary navigation simulation results. We also describe the TRN PIL tests on a flight-like development board, using simulated images rendered from Lunar Reconnaissance Orbit high-resolution digital terrain models. The navigation simulations show that weak-signal GPS combined with TRN during a descent from a low lunar parking orbit results in sufficiently low navigation uncertainties to support such a mission profile independent of ground-based navigation. The PIL tests show that onboard image processing and landmark correlation is achievable at a sufficiently high measurement rate.

Michael A Shoemaker↗

DeepMerge: Classifying high-redshift merging galaxies with deep neural networks

In this work, we investigate and demonstrate the use of convolutional neural networks (CNNs) for the task of distinguishing between merging and non-merging galaxies in simulated images, and for the first time at high redshifts (i.e. $z=2$). We extract images of merging and non-merging galaxies from the Illustris-1 cosmological simulation and apply observational and experimental noise that mimics that from the Hubble Space Telescope; the data without noise form a "pristine" data set and that with noise form a "noisy" data set. The test set classification accuracy of the CNN is $79\%$ for pristine and $76\%$ for noisy. The CNN outperforms a Random Forest classifier, which was shown to be superior to conventional one- or two-dimensional statistical methods (Concentration, Asymmetry, the Gini, $M_{20}$ statistics etc.), which are commonly used when classifying merging galaxies. We also investigate the selection effects of the classifier with respect to merger state and star formation rate, finding no bias. Finally, we extract Grad-CAMs (Gradient-weighted Class Activation Mapping) from the results to further assess and interrogate the fidelity of the classification model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First D+D neutron image at the National Ignition Facility

First time-integrated neutron images of a deuterium gas filled capsule were obtained using arrival time gating with the Neutron Imaging System at the National Ignition Facility. Images exist from DT (deuterium and tritium mixture) filled capsules in several energy bands but only at the Omega laser had DD (pure deuterium) filled capsules been imaged. A composite image was derived from an assembly of multiple penumbral neutron images using an iterative Maximum Likelihood reconstruction technique. This was compared with a simulated image from a radiation-hydrodynamic calculation. The observed image size, and shape agree, as do the primary DD, secondary DT neutron yields, and the burn duration. However, the observed cross-sectional profiles, although smaller in half width, extend outside the calculated, suggesting that deuterium has mixed outward into the carbon ablator. The observed X-ray image size (61 μm) is larger than the observed neutron image (51 μm). The calculations also reflect this. X-ray brightness includes carbon as well as deuterium emission. A bright spot, “meteor,” in the X-ray image is seen to move in time-gated images, but is not evident in the neutron image. It does not appear to degrade the neutron yield.

42 ENGINEERING↗

An operational method for estimating signal to noise ratios from data acquired with imaging spectrometers

A method, using the concept of local means and local standard deviations of small imaging blocks and using a box counting procedure, has been developed for unsupervised estimation of the average signal to noise ratios of images in which the noise is additive. The method has been applied to simulated images with Gaussian noise, to images acquired with the Airborne Visible Infrared Imaging Spectrometer and with the Geophysical and Environmental Research Imaging Spectrometer. The method is compared with other techniques for estimating signal to noise ratios from imaging data. It is believed that the method is generally applicable to images having many small homogeneous blocks. Because the method does not take into account interband effects, it is not appropriate to use the method to estimate signal to noise ratios from images having nonnegligible interband radiometric calibration errors at spatial scales less than or equal to the size of the small imaging blocks used in the noise estimation.

Gao, Bo-Cai↗

Investigation of Point Defects by Aberration-Corrected STEM and First-Principles Theory

The successful correction of aberrations in scanning transmission electron microscopy (STEM) has improved lateral resolution by more than a factor of two [1], brought greatly enhanced sensitivity for imaging individual atoms, and depth resolution of a few nanometers [2-4]. In zone axis crystals, columnar channeling tends to reduce the depth resolution, and image simulations are necessary to establish the depth sensitivity [5]. To illustrate this capability, images from Si nanowires grown by a Au-catalyzed vapour-liquid-solid method will be presented [6]. A high density of Au atoms are seen not only on the surface of the nanowires, but, by changing focus, are seen also in the bulk of the nanowire, as shown in Fig. 1. The gold atoms move under the influence of the beam, and may not be present in the as-grown material. However, substitutional and three interstitial configurations are found, which are confirmed by density functional calculations to be stable (substitutional) or metastable (interstitial) sites. Furthermore, the number density of the different configurations correlates with their calculated defect formation energies. As a second example of the identification of a point defect complex, the origin of ferromagnetism in Co-doped anatase will be shown by a combination of imaging, EELS and theory to be a Co-Ti+3-VO complex [7].

Pennycook, Stephen J↗

Spatial and spectral simulation of LANDSAT images of agricultural areas

A LANDSAT scene simulation capability was developed to study the effects of small fields and misregistration on LANDSAT-based crop proportion estimation procedures. The simulation employs a pattern of ground polygons each with a crop ID, planting date, and scale factor. Historical greenness/brightness crop development profiles generate the mean signal values for each polygon. Historical within-field covariances add texture to pixels in each polygon. The planting dates and scale factors create between-field/within-crop variation. Between field and crop variation is achieved by the above and crop profile differences. The LANDSAT point spread function is used to add correlation between nearby pixels. The next effect of the point spread function is to blur the image. Mixed pixels and misregistration are also simulated.

Pont, W. F., Jr.↗

Spatial and spectral simulation of Landsat images of agricultural areas

A Landsat scene simulation capability was developed to study the effects of small fields and misregistration on Landsat-based crop proportion estimation procedures. The simulation employs a pattern of ground polygons each with a crop ID, planting date, and scale factor. Historical greenness/brightness crop development profiles generate the mean signal values for each polygon. Historical within-field covariances add texture to pixels in each polygon. The planting dates and scale factors create between-field/within-crop variation. Between field and crop variation is achieved by the above and crop profile differences. The Landsat point spread function is used to add correlation between nearby pixels. The next effect of the point spread function is to blur the image. Mixed pixels and misregistration are also simulated. Previously announced in STAR as N82-32813

Pont, W. F., Jr.↗

WE-G-204-04: Focal Spot Deblurring For High Resolution Amorphous Selenium (aSe) Complementary Metal Oxide Semiconductor (CMOS) X-Ray Detector

Purpose: CMOS-based aSe detectors compared to CsI-TFT-based flat panels have the advantages of higher spatial sampling due to smaller pixel size and decreased blurring characteristic of direct rather than indirect detection. For systems with such detectors, the limiting factor degrading image resolution then becomes the focal-spot geometric unsharpness. This effect can seriously limit the use of such detectors in areas such as cone beam computed tomography, clinical fluoroscopy and angiography. In this work a technique to remove the effect of focal-spot blur is presented for a simulated aSe detector. Method: To simulate images from an aSe detector affected with focal-spot blur, first a set of high-resolution images of a stent (FRED from Microvention, Inc.) were acquired using a 75µm pixel size Dexela-Perkin-Elmer detector and averaged to reduce quantum noise. Then the averaged image was blurred with a known Gaussian blur at two different magnifications to simulate an idealized focal spot. The blurred images were then deconvolved with a set of different Gaussian blurs to remove the effect of focal-spot blurring using a threshold-based, inverse-filtering method. Results: The blur was removed by deconvolving the images using a set of Gaussian functions for both magnifications. Selecting the correct function resulted in an image close to the original; however, selection of too wide a function would cause severe artifacts. Conclusion: Experimentally, focal-spot blur at different magnifications can be measured using a pin hole with a high resolution detector. This spread function can be used to deblur the input images that are acquired at corresponding magnifications to correct for the focal spot blur. For CBCT applications, the magnification of specific objects can be obtained using initial reconstructions then corrected for focal-spot blurring to improve resolution. Similarly, if object magnification can be determined such correction may be applied in fluoroscopy and angiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Al rich (111) and (110) surfaces of LaAlO 3

Lanthanum aluminate (LaAlO 3 ) has garnered significant interests since the discovery of a 2D electron gas at the LaAlO 3 /SrTiO 3 interface. Here in this work, the (110) surface of LaAlO 3 was studied using a combination of transmission electron microscopy plan and profile imaging, image simulation, electron diffraction, X-ray photoelectron spectroscopy, and density functional theory calculations. Profile imaging of the (110) surface was performed on a (111) oriented single crystalline sample with an Al rich surface. Our results indicate that high annealing temperatures (1000–1300°C) commonly used in preparing well ordered, flat surfaces of LaAlO 3 result in Al rich surfaces. The (110) surface was found to be single layered AlO x with a (2 × 1) reconstruction. Angle resolved X-ray photoelectron spectroscopy indicated that the (2 × 1) surface structure was not hydrated. Convex hull construction of surface enthalpies as a function of excess AlO 1.5 on the (110) surface was done using density functional theory calculations.

36 MATERIALS SCIENCE↗

Tests of a simple data merging algorithm for the GONG project

The GONG (Global Oscillation Network Group) project proposes to reduce the impact of diurnal variations on helioseismic measurements by making long-term observations of solar images from six sites placed around the globe. The sun will be observed nearly constantly for three years, resulting in the acquisition of l+ terabyte of image data. To use the solar network to maximum advantage, the images from the sites must be combined into a single time series to determine mode frequencies, amplitudes, and line widths. Initial versions of combined, i.e., merged, time series were made using a simple weighted average of data from different sites taken simultaneously. In order to accurately assess the impact of the data merge on the helioseismic measurements, a set of artificial solar disk images was made using a standard solar model and containing a well known set of oscillation modes and frequencies. This undegraded data set and data products computed from it were used to judge the relative merits of various data merging schemes. The artificial solar disk images were subjected to various instrumental and atmospheric degradations, dependent on site and time, in order to create a set of images simulating those likely to be taken at the site. The degraded artificial solar disk images for the six observing sites were combined in various ways to form merged time series of images and mode coefficients. Various forms of a weighted average were used, including an equally-weighted average, an average with weights dependent upon air mass and averages with weights dependent on various quality assurance parameters. Both the undegraded solar disk image time series and several time series made up of various combinations of the degraded solar disk images from the six sites were subjected to standard helioseismic measurement processing. This processing consisted of coordinate remapping, detrending, spherical harmonic transformation, computation of power series for the oscillation mode coefficients, and mode frequency identification. Visual and statistical evaluation of the merged data sets themselves and differences between the merged and undegraded data set shows good agreement between the two data sets. Some slight differences in image scale and registration appear between the undegraded data set and the various merged data sets. In the set of power series made from the mode coefficients of the merged data sets, some power leakage is observed into the background and into slightly lower l-value modes, especially at higher l-value mode frequencies. The results of the comparison of time series and mode oscillation frequencies of the undegraded data with those of the data merged using weighted averages indicate that, at least for p-mode solar oscillations, a weighted average of either the detrended remapped images or the mode coefficients gives good determination of the mode frequencies and adequate-to-good determination of the amplitudes and widths of the mode frequency lines. This conclusion is most advantageous to the analysis of the massive amounts of data to be received by the GONG network.

Williams, W. E.↗

Removing imaging systematics from galaxy clustering measurements with Obiwan: application to the SDSS-IV extended Baryon Oscillation Spectroscopic Survey emission-line galaxy sample

This article presents the application of a new tool, Obiwan, which uses image simulations to determine the selection function of a galaxy redshift survey and calculate three-dimensional (3D) clustering statistics. Obiwan relies on a forward model of the process by which images of the night sky are transformed into a 3D large-scale structure catalogue, and offers several advantages over more traditional map-based techniques – such as operating on individual exposures and adopting a maximum likelihood approach. The photometric pipeline automatically detects and models galaxies and then generates a catalogue of such galaxies with detailed information for each one of them, including their location, redshift, and so on. Systematic biases in the imaging data are therefore imparted into the catalogues and must be accounted for in any scientific analysis of their information content. Obiwan simulates this process for samples selected from the Legacy Surveys imaging data. This imaging data will be used to select target samples for the next-generation Dark Energy Spectroscopic Instrument (DESI) experiment. Here, we apply Obiwan to a portion of the SDSS-IV extended Baryon Oscillation Spectroscopic Survey emission-line galaxies (ELGs). Systematic biases in the data are clearly identified and removed. We compare the 3D clustering results to those obtained by the map-based approach applied to the complete eBOSS Data Release 16 (DR16) sample. We find the results are consistent, thereby validating the eBOSS DR16 ELG catalogues, which is used to obtain cosmological results.

79 ASTRONOMY AND ASTROPHYSICS↗

ELLIPTICAL WEIGHTED HOLICs FOR WEAK LENSING SHEAR MEASUREMENT. III. THE EFFECT OF RANDOM COUNT NOISE ON IMAGE MOMENTS IN WEAK LENSING ANALYSIS

This is the third paper on the improvement of systematic errors in weak lensing analysis using an elliptical weight function, referred to as E-HOLICs. In previous papers, we succeeded in avoiding errors that depend on the ellipticity of the background image. In this paper, we investigate the systematic error that depends on the signal-to-noise ratio of the background image. We find that the origin of this error is the random count noise that comes from the Poisson noise of sky counts. The random count noise makes additional moments and centroid shift error, and those first-order effects are canceled in averaging, but the second-order effects are not canceled. We derive the formulae that correct this systematic error due to the random count noise in measuring the moments and ellipticity of the background image. The correction formulae obtained are expressed as combinations of complex moments of the image, and thus can correct the systematic errors caused by each object. We test their validity using a simulated image and find that the systematic error becomes less than 1% in the measured ellipticity for objects with an IMCAT significance threshold of {nu} {approx} 11.7.

79 ASTRONOMY AND ASTROPHYSICS↗

FURTHER EVALUATION OF BOOTSTRAP RESAMPLING AS A TOOL FOR RADIO-INTERFEROMETRIC IMAGING FIDELITY ASSESSMENT

We report on a broader evaluation of statistical bootstrap resampling methods as a tool for pixel-level calibration and imaging fidelity assessment in radio interferometry. Pixel-level imaging fidelity assessment is a challenging problem, important for the value it holds in robust scientific interpretation of interferometric images, enhancement of automated pipeline reduction systems needed to broaden the user community for these instruments, and understanding leading-edge direction-dependent calibration and imaging challenges for future telescopes such as the Square Kilometre Array. This new computational approach is now possible because of advances in statistical resampling for data with long-range dependence and the available performance of contemporary high-performance computing resources. We expand our earlier numerical evaluation to span a broader domain subset in simulated image fidelity and source brightness distribution morphologies. As before, we evaluate the statistical performance of the bootstrap resampling methods against direct Monte Carlo simulation. We find that both model-based and subsample bootstrap methods continue to show significant promise for the challenging problem of interferometric imaging fidelity assessment when evaluated over the broader domain subset. We report on their measured statistical performance and guidelines for their use and application in practice. We also examine the performance of the underlying polarization self-calibration algorithm used in this study over a range of parallactic angle coverage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility of an image planning system for kilovoltage image-guided radiation therapy

Purpose: Image guidance has become a standard of care for many treatment scenarios in radiation therapy. This is most typically accomplished by use of kV x-ray devices mounted onto the linear accelerator (Linac) gantry that yield planar, fluoroscopic, and cone-beam computed tomography (CBCT) images. Image acquisition parameters are chosen via preset techniques that rely on broad categorizations in patient anatomy and imaging goal. However, the optimal imaging technique results in detectability of the features of interest while exposing the patient to minimum dose. Herein, the authors present an investigation into the feasibility of developing an image planning system (IPS) for radiotherapy.Methods: In this first phase, the authors focused on developing an algorithm to predict tissue contrast produced by a common radiotherapy planar imaging chain. Input parameters include a CT dataset and simulated planar imaging technique settings that include kV and mAs. Energy-specific attenuation through each voxel of the CT dataset was calculated in the algorithm to derive a net transmitted intensity. The response of the flat panel detector was integrated into the image simulation algorithm. Verification was conducted by comparing simulated and measured images using four phantoms. Comparisons were made in both high and low contrast settings, as well as changes in the geometric appearance due to image saturation. Results: The authors studied a lung nodule test object to assess the planning system's ability to predict object contrast and detectability. Verification demonstrated that the slope of the pixel intensities is similar, the presence of the nodule is evident, and image saturation at high mAs values is evident in both images. The appearance of the lung nodule is a function of the image detector saturation. The authors assessed the dimensions of the lung nodule in measured and simulated images. Good quantitative agreement affirmed the algorithm's predictive capabilities. The invariance of contrast with kVp and mAs prior to saturation was predicted, as well as the gradual loss of object detectability as saturation was approached. Small changes in soft tissue density were studied using a mammography step wedge phantom. Data were acquired at beam qualities of 80 and 120 kVp and over exposure values ranging from 0.04 to 500 mAs. The data showed good agreement in terms of the absolute value of pixel intensities predicted, as well as small variations across the step wedge pattern. The saturation pixel intensity was consistent between the two beam qualities studied. Boney tissue contrast was assessed using two abdominal phantoms. Measured and calculated values agree in terms of predicting the mAs value at which detector saturation, and subsequent loss of contrast occurs. The lack of variation in contrast over mAs values lower than 10 suggests that there is wide latitude for minimizing patient dose. Conclusions: The authors developed and tested an algorithm that can be used to assist in kV imaging technique selection during localization for radiotherapy. Phantom testing demonstrated the algorithm's predictive accuracy for both low and high contrast imaging scenarios. Detector saturation with subsequent loss of imaging detail, both in terms of object size and contrast were accurately predicted by the algorithm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

HARD X-RAY IMAGING OF SOLAR FLARES USING INTERPOLATED VISIBILITIES

RHESSI produces solar flare images with the finest angular and spectral resolutions ever achieved at hard X-ray energies. Because this instrument uses indirect, collimator-based imaging techniques, the 'native' output of which is in the form of 'visibilities' (two-dimensional spatial Fourier components of the image), the development and application of robust, accurate, visibility-based image reconstruction techniques is required. Recognizing that the density of spatial-frequency (u, v) coverage by RHESSI is much sparser than that normally encountered in radio astronomy, we therefore introduce a method for image reconstruction from a relatively sparse distribution of sampled visibilities. The method involves spline interpolation at spatial frequencies less than the largest sampled frequency and the imposition of a positivity constraint on the image to reduce the ringing effects resulting from an unconstrained Fourier transform inversion procedure. Using simulated images consisting both of assumed mathematical forms and of the type of structure typically associated with solar flares, we validate the fidelity, accuracy, and robustness with which the new procedure recovers input images. The method faithfully recovers both single and multiple sources, both compact and extended, over a dynamic range of approx10:1. The performance of the method, which we term as uv{sub s}mooth, is compared with other RHESSI image reconstruction algorithms currently in use and its advantages summarized. We also illustrate the application of the method using RHESSI observations of four solar flares.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance and Image Analysis of the Aberration Corrected Hitachi HD-2700C Stem

We report the performance of the first aberration-corrected scanning transmission electron microscope (STEM) manufactured by Hitachi. We describe its unique features and versatile capabilities in atomic-scale characterization and its applications in materials research. We also discuss contrast variation of the STEM images obtained from different annular dark-field (ADF) detectors of the instrument, and the increased complexity in contrast interpretation and quantification due to the increased convergent angles of the electron probe associated with the aberration corrector. We demonstrate that the intensity of atomic columns in an ADF image depends strongly on a variety of imaging parameters, sample thickness, as well as the nuclear charge and the deviation from their periodic position of the atoms we are probing. Image simulations are often required to correctly interpret the atomic structure of an ADF-STEM image.

36 MATERIALS SCIENCE↗

High Resolution Topography Analysis on Threading Edge Dislocations in 4H-SiC Epilayers

Threading edge dislocations (TEDs) in a 4H-SiC epitaxial layer are investigated using high-resolution synchrotron topography. Six types of TED image are confirmed to correspond to the Burgers vector directions by a comparison of computer simulated images and observed topography images in crystal boundaries. Using a mapping method, a wide spatial distribution of the six types of TED is examined in a quarter section of a 2-inch wafer.

36 MATERIALS SCIENCE↗