Search NASA⌕ Search

SEARCH · Search NASA

Results for “Incidence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Congenital malformation and hemoglobin A1c in the first trimester among Japanese women with pregestational diabetes

Abstract Aim To investigate the incidence of major congenital malformations in Japanese women with pregestational diabetes, and to determine the cutoff value of hemoglobin A1c (HbA1c) in the first trimester associated with congenital malformations. Methods This retrospective cohort study included singleton pregnancies in Japanese women with pregestational diabetes, including type 1 and type 2 diabetes, and specific types of diabetes due to other causes. The primary outcome was the incidence of major congenital malformations. The secondary outcome was the incidence of all congenital malformations. The cutoff value of HbA1c for congenital malformations was calculated using receiver operating characteristic curve analysis. The adjusted odds ratios (aOR) of major congenital malformations were calculated using multiple logistic regression analyses. Results This study enrolled 292 patients, including 132 (45.2%) with type 1 diabetes, 156 (53.4%) with type 2 diabetes, and 4 (1.4%) with other specific types. The incidence rates of major congenital malformations and all congenital malformations were 7.2% (21/292) and 12.7% (37/292), respectively. The cutoff value of HbA1c in the first trimester for major malformations and for all congenital malformations was 6.5%. HbA1c ≥ 6.5% was significantly associated with major malformations (aOR 3.5; 95% confidence interval: 1.2–12.6; p = 0.018). Conclusion The incidence of major congenital malformations significantly increased in pregnant Japanese women with HbA1c values of 6.5% or higher. The recommended HbA1c value during the first trimester used in other countries can be applied to pregnant Japanese women.

Nakanishi, Kentaro↗

Boson Fermion Nucleus Explanation for Fission Fragment Anisotropy: Monograph #13

Since 1952, anisotropy has been observed in the paths of fission fragments following the assimilation of an incident neutron or photon in the nucleus. Fission fragment flux favors certain angles relative to the path of the incident particle, constituting anisotropy. The amount of anisotropy is dependent on the energy of the incident particle. Fission fragment anisotropy can be explained by the disruption of nuclear structure combined with the requirement of a specific rotational orientation in theta and phi of that structure relative to the incident neutron or photon flux. A specific and limited area in the nucleus can assimilate the incident particle and induce upset within the structure, followed by scission and fission of the nucleus. The orientation and nature of the structure upset dictates fission fragment trajectory and is responsible for fission fragment anisotropy. This concept can be explained and supported by the theory of boson fermion nucleus (BFN) structure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Energy-dependent optimization of the prompt fission neutron spectrum with CGMF

Throughout the course of FY21, significant effort was put into investigating models within the LANL developed Hauser-Feshbach fission fragment decay code, CGMF, to understand and potentially solve the long-standing challenge of a too-soft prompt fission neutron spectrum, PFNS. Several inputs and models to CGMF were investigated, including the discrete nuclear levels, the optical model potential, level densities, and the fission fragment initial conditions. Some of the global models within CGMF led to a slight hardening of the neutron spectrum—particularly the likely incomplete discrete levels in through which γ-rays decay—but none of the changes where large enough for the tail of the PFNS to reproduce experimental data. A significant hardening of the spectrum tail was observed when the fission fragment initial conditions were optimized based on their sensitivities to the PFNS data for thermal incident neutrons. In this way, the parameters for the CGMF mass and total kinetic energy distributions, along with the spin cutoff factor were adjusted to better reproduce the experimental PFNS measurements. This optimization hardened the tail of the PFNS slightly but led to unphysical mass distributions for the fission fragments before neutron emission. It was clear from the above that we do not expect to be able to produce an evaluation-quality PFNS with CGMF in the near future. Challenges at thermal will persist–and possibly worsen–with increasing incident energy, where more models are needed to completely describe the fission. Basic-science research funding exceeding the amount available and scope of our NCSP funds would be needed to tackle this decade-long challenge impacting many fission-fragment event generator. And, in fact, Amy Lovell won LDRD ECR funding to do so over the next few years. Therefore, we focused in FY22 on extending evaluation capabilities beyond thermal incident neutrons, to take into account the incident energy dependence of the PFNS and fission fragment initial condition distributions in CGMF. We chose to set up the evaluation methodology to perform PFNS evaluations with CGMF across incident-neutron energies, in order to have it readily available for future NCSP evaluations when the PFNS from CGMF has improved. In this report, we outline the evaluation methodology, along with the results of the optimization, including full model calculations with CGMF using the evaluated parameters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FRMAC Laboratory Analysis Manual Volume 1, Revision 0

This manual is written for personnel who respond to a nuclear/radiological incident and will be called upon to provide support to ensure that samples receive appropriate laboratory analyses. Overall, this manual provides general guidance and some specific diagrams and forms. However, it is understood that site- and incident-specific operational decisions and procedures may need to be modified at the time of the incident. This manual is intended to provide guidance for laboratory analysis personnel without limiting FRMAC’s ability to integrate the work with other partners and stakeholders. Some of the titles of management positions with the FRMAC have been changed in order to comply with the structure of the Incident Command System (ICS) under the National Incident Management System (NIMS).

61 RADIATION PROTECTION AND DOSIMETRY↗

Advances in statistical methods for cancer surveillance research: an age-period-cohort perspective

Background: Analysis of Lexis diagrams (population-based cancer incidence and mortality rates indexed by age group and calendar period) requires specialized statistical methods. However, existing methods have limitations that can now be overcome using new approaches. Methods: We assembled a “toolbox” of novel methods to identify trends and patterns by age group, calendar period, and birth cohort. We evaluated operating characteristics across 152 cancer incidence Lexis diagrams compiled from United States (US) Surveillance, Epidemiology and End Results Program data for 21 leading cancers in men and women in four race and ethnicity groups (the “cancer incidence panel”). Results: Nonparametric singular values adaptive kernel filtration (SIFT) decreased the estimated root mean squared error by 90% across the cancer incidence panel. A novel method for semi-parametric age-period-cohort analysis (SAGE) provided optimally smoothed estimates of age-period-cohort (APC) estimable functions and stabilized estimates of lack-of-fit (LOF). SAGE identified statistically significant birth cohort effects across the entire cancer panel; LOF had little impact. As illustrated for colon cancer, newly developed methods for comparative age-period-cohort analysis can elucidate cancer heterogeneity that would otherwise be difficult or impossible to discern using standard methods. Conclusions: Cancer surveillance researchers can now identify fine-scale temporal signals with unprecedented accuracy and elucidate cancer heterogeneity with unprecedented specificity. Birth cohort effects are ubiquitous modulators of cancer incidence in the US. The novel methods described here can advance cancer surveillance research.

60 APPLIED LIFE SCIENCES↗

Ionizing-radiation beam monitoring system

A transmissive ionizing-radiation beam monitoring system includes an enclosure structure with at least one ultra-thin window to an incident ionizing-radiation beam, where the ultra-thin window is highly transmissive to ionizing-radiation. Embodiments include at least one thin or ultra-thin scintillator within the enclosure structure that is substantially directly in an incident ionizing-radiation beam path and transmissive to the incident radiation beam, and at least one ultraviolet (UV) illumination source within the enclosure structure facing the scintillator. Embodiments include at least one machine vision camera within the enclosure structure located out of an incident ionizing-radiation beam path and including a camera body and lens having a projection of its optical axis oriented at an angle of incidence of 45±35 degrees to a surface of the scintillator.

Friedman, Peter S.↗

Thirdhand tobacco smoke exposure increases the genetic background-dependent risk of pan-tumor development in Collaborative Cross mice

Increasing evidence has shown that thirdhand smoke (THS) exposure is likely to induce adverse health effects. An important knowledge gap remains in our understanding of THS exposure related to cancer risk in the human population. Population-based animal models are useful and powerful in investigating the interplay between host genetics and THS exposure on cancer risk. Here, we used the Collaborative Cross (CC) mouse population-based model system, which recapitulates the genetic and phenotypic diversity observed in the human population, to assess cancer risk after a short period of exposure, between 4 and 9 weeks of age. Eight CC strains (CC001, CC019, CC026, CC036, CC037, CC041, CC042 and CC051) were included in our study. We quantified pan-tumor incidence, tumor burden per mouse, organ tumor spectrum and tumor-free survival until 18 months of age. At the population level, we observed a significantly increased pan-tumor incidence and tumor burden per mouse in THS-treated mice as compared to the control (p = 3.04E-06). Lung and liver tissues exhibited the largest risk of undergoing tumorigenesis after THS exposure. Tumor-free survival was significantly reduced in THS-treated mice compared to control (p = 0.044). At the individual strain level, we observed a large variation in tumor incidence across the 8 CC strains. CC036 and CC041 exhibited a significant increase in pan-tumor incidence (p = 0.0084 and p = 0.000066, respectively) after THS exposure compared to control. We conclude that early-life THS exposure increases tumor development in CC mice and that host genetic background plays an important role in individual susceptibility to THS-induced tumorigenesis. Genetic background is an important factor that should be taken into account when determining human cancer risk of THS exposure.

60 APPLIED LIFE SCIENCES↗

Micro-trench measurements of the net deposition of carbon impurity ions in the DIII-D divertor and the resulting suppression of surface erosion

In this work, we report carbon impurity ion incident angles and deposition rates, along with silicon erosion rates, from measurements of micro-engineered trenches on a silicon surface exposed to L-mode deuterium plasmas at the DIII-D divertor. Post exposure ex-situ analysis determined elemental maps and concentrations, carbon deposition thicknesses, and erosion of silicon surfaces. Carbon deposition profiles on the trench floor showed carbon ion shadowing that was consistent with ERO calculations of average carbon ion angle distributions (IADs) for both polar and azimuthal angles. Measured silicon net erosion rates negatively correlated with the deposited carbon concentration at different locations. Differential erosion of surfaces on two different ion-downstream trench slope structures suggested that carbon deposition rate is affected by the carbon ion incident angle and significantly suppressed the surface erosion. The results suggest the C impurity ion incident angles, determined by the IADs and surface morphology, strongly affect erosion rates as well as the main ion (D, T, He) incident angles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lateral Beam Shifts and Depolarization Upon Oblique Reflection from Dielectric Mirrors

Abstract Dielectric mirrors comprising thin‐film multilayers are widely used in optical experiments because they can achieve substantially higher reflectance compared to metal mirrors. Here, potential problems are investigated that can arise when dielectric mirrors are used at oblique incidence, in particular for focused beams. It is found that light beams reflected from dielectric mirrors can experience lateral beam shifts, beam‐shape distortion, and depolarization, and these effects have a strong dependence on wavelength, incident angle, and incident polarization. Because vendors of dielectric mirrors typically do not share the particular layer structure of their products, several dielectric‐mirror stacks are designed and simulated, and then the lateral beam shift from two commercial dielectric mirrors and one coated metal mirror is also measured. This paper brings awareness of the tradeoffs between dielectric mirrors and front‐surface metal mirrors in certain optics experiments, and it is suggested that vendors of dielectric mirrors provide information about beam shifts, distortion, and depolarization when their products are used at oblique incidence.

Physics↗

Model predictive current profile control in tokamaks by exploiting spatially moving electron cyclotron current drives

The plasma control systems in next-generation tokamaks like ITER will balance competing control objectives to achieve the desired level of performance in advanced scenarios while preventing magnetohydrodynamic instabilities and disruptions. During normal tokamak operation, the points of incidence of the electromagnetic waves generated by the electron cyclotron heating and current drives (EC H&CDs) are usually fixed in space. However, the points of incidence can be modified in real-time by changing the angles of the mirrors that reflect the EC H&CD waves. Altering the points of incidence, in turn, varies the ability of the plasma control system to regulate a plasma property. For instance, changing the EC H&CD wave incidence location may place the power demands necessary to achieve a particular plasma target within saturation limits. Therefore, using the EC H&CD deposition location, which is related to the EC H&CD mirror angle, as a supplementary controllable variable may facilitate access to a given target scenario. However, active scenario-control algorithms have not been designed so far to fully exploit this capability in real time. In this work, a model predictive controller that can handle actuation locations as control inputs is developed. In particular, the controller is designed to regulate both the auxiliary powers and the EC H&CD deposition locations in a pre-defined optimal sense to achieve the control objective of attaining and sustaining a target current profile. Further, the proposed controller is tested for a DIII-D tokamak scenario in nonlinear simulations using the Control Oriented Transport SIMulator (COTSIM).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of electron backscattering in the MCNP6.3 code

A new electron backscattering validation suite has been developed for the MCNP® code. The calculations in this suite cover both condensed history and single-event transport methods, seven different elemental materials ranging from beryllium to uranium, and incident electron energies from 200 eV to 14.1 MeV. In general, the accuracy of the MCNP code for electron backscattering calculations is energy-dependent. For incident electron energies below 2 keV, the condensed history method is not applied while the single-event method shows poor agreement with experimental measurements due to poor accuracy of the underlying atomic data. For incident energies between 2 keV and 256 keV, the single-event method typically shows better agreement with experiments, while for incident energies above 256 keV the condensed history method gives better accuracy. Additionally, agreement with experimental data is generally worse for low- Z materials such as beryllium and carbon, which may reflect deficiencies in the data or physics underlying electron transport through light elements in the MCNP code. The new electron backscattering validation suite, along with the previously introduced electron stopping power and Lockwood energy deposition validation suites, provide MCNP users with a quantified understanding of the uncertainties in electron transport calculations. Future improvements to electron transport in the MCNP code are necessary for low energies (≤ 2 keV) and for low- Z materials.

36 MATERIALS SCIENCE↗

The last Black man with HIV in San Francisco: the potential role of gentrification on HIV getting to zero achievements

San Francisco was the first city in the USA to develop a Getting to Zero HIV elimination strategy. The cause of decreased HIV incidence has been attributed to the use of biomedical prevention methods, such as pre-exposure prophylaxis (PrEP) and treatment as prevention (TasP). These strategies have benefitted White men who have sex with men (MSM), whose population has increased over the past decade. However, Black MSM in San Francisco continue to have higher HIV incidence and outmigration rates. We posit that the declining overall HIV incidence, including among White MSM, is not only explained by the use of TaSP and PrEP, but is also due to the declining Black population and rising HIV incidence among Black MSM, who have historically been more likely to acquire HIV due to structural, racial, and criminal justice-related factors than have White MSM.

60 APPLIED LIFE SCIENCES↗

Examining astrophysical gas cloud collapse using an optical depth-scaled, x-ray-irradiated, carbon-foam sphere

When stellar radiation interacts with a molecular cloud, the cloud's fate depends on the strength of the incident radiation and the radiation's mean-free-path within the cloud [F. Bertoldi, Astrophys. J. 346, 735–755 (1989)]. Under the right conditions, the radiation compresses the cloud and a star formation may occur. Where and when the stellar formation occurs in the cloud's collapse are open questions. Direct observation of the complete star–cloud lifecycle is nearly impossible due to the immense timescales and distances over which the interaction occurs. Laboratory astrophysics offers a way to investigate such a system by scaling the important astrophysical parameters to the laboratory. This work describes laboratory experiments to study the radiation-driven implosion of clouds, using x rays from a laser-irradiated, thin, gold foil as a surrogate star and a carbon-foam sphere as a surrogate cloud. An optically thick system, theoretically corresponding to a star-forming regime, was selected by choice of the foam density. Gold foil and sphere motions were imaged by x-ray radiography. Radiographic images show the formation of an interface between rarefied gold and carbon plasmas, a shock moving into the sphere, and a blunting of the initial sphere's shape. Measurements show that the shock moved linearly around 64 μm/ns into the sphere, and the gold–carbon interface formed by 2 ns at the sphere edge remained stationary. The deformation of the sphere was driven by the incident radiation and not by mechanical pressures applied by gold plasma. The blunting of the sphere was likely due to the geometric reduction of flux near the sphere's poles. Higher x-ray flux near the sphere's equator caused high compression and a faster shock, which flattened the sphere. We will discuss the results and implications of our observations.

VanDervort, R. W. [University of Michigan 1 , Ann ↗

Low-energy ion beam sputtering of polycrystalline diamond

Ion beam milling is a highly versatile and precise technique for the microfabrication of diamond films, enabling controlled material removal at both micrometer and sub-micrometer scales while accommodating complex geometries and surface features. Comprehensive sputtering yield data are essential for process optimization. In this work, we systematically measure the sputter yield of polycrystalline diamond bombarded with $\textrm{N}_2^+$, Ne + , Ar + , Kr + , and Xe + ions over an energy range of 300–900 eV and beam incidence angles of 0°−80°, providing data critical for precision machining applications. Results show that the sputter yield increases with both ion energy and the incidence angle and decreases with increasing ion mass. For $\textrm{N}_2^+$ ions, the sputter yield is largely insensitive to ion energy and exceeds values expected for pure physical sputtering. The concurrent formation of volatile C 2 N 2 molecules during $\textrm{N}_2^+$ ion bombardment suggests that the process is dominated by chemical sputtering. The absence of a peak in the dependence of the sputter yield on the beam incidence angle expected at oblique incidence angles is attributed to the effects of surface roughness.

Materials science↗

Performance Comparison of Helium and sCO 2 as Coolants for Modular Finger-Type Divertors

Several studies at the Georgia Institute of Technology have evaluated the thermal and fluids performance of the helium-cooled modular divertor with multiple jets (HEMJ) over the past decade. This finger-type divertor was studied both experimentally at nearly prototypical conditions and numerically at fully prototypical operating conditions using experimentally validated simulations. Recently, supercritical carbon dioxide (sCO 2 ) has been studied as the primary coolant in power cycles and other applications in various systems, in part because CO 2 achieves the high densities typical of supercritical fluids at relatively low temperatures and pressures, with a critical point of (7.38 MPa, 31°C). This density makes it possible to realize very compact and efficient sCO 2 power cycles. The feasibility of sCO 2 as a coolant for plasma-facing components, specifically the divertor, was therefore evaluated as part of the Fusion Energy System Studies design study activities. This work compares the thermal-fluid performance of helium and sCO 2 in the HEMJ divertor geometry using numerical simulations at prototypical conditions: inlet temperatures T i = 600°C to 700°C, pressures p ≈ 10 MPa, and steady-state incident heat fluxes on the tile q″ < 17 MW/m 2 . The performance is quantified here as the maximum heat flux that can be accommodated by the plasma-facing tile, the pumping power fraction, defined as the ratio of the coolant pumping power to the incident thermal power, and the operating stress limits based on ASME pressure vessel criteria. As expected, helium requires lower mass flow rates and pumping power fractions within imposed maximum temperature limits for the HEMJ pressure boundary. However, it also appears that neither helium nor sCO 2 can remove 10 MW/m 2 of incident heat flux while meeting ASME pressure vessel criteria. Finally, the numerical modeling reveals that sCO 2 may remove slightly higher incident heat fluxes than helium due to the imposed stress limits due to the sCO 2 coolant resulting in smaller local temperature gradients, albeit at a considerably higher pumping power fraction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Association between the findings of metachronous secondary primary malignancies and the number of Lugol-voiding lesions

Summary This study was designed to evaluate the relation between dysplastic squamous epithelium in the esophageal mucosa and the development of metachronous secondary primary malignancies (mSPM) other than esophagus after endoscopic resection (ER) in patients with early esophageal squamous cell carcinoma (SCC). We studied 330 patients with early esophageal SCC who underwent ER as a post hoc analysis of a prospective multicenter cohort study (UMIN Clinical Trials Registry ID UMIN000001676). Lugol-voiding lesions (LVL) were graded into 3 categories (A = no lesion; B = 1 to 9 lesions; C ≥ 10 lesions). The following variables were studied: (i) the incidences of mSPM other than esophagus; (ii) the standardized incidence ratios (SIRs) of mSPM; (iii) the cumulative incidence and total number of mSPM other than esophagus; and (iv) predictors of mSPM other than esophagus on analysis with a multivariate Cox proportional-hazards model. After a median follow-up of 46.6 months, mSPM other than esophagus was diagnosed in a total of 73 patients (90 lesions). Among the 106 patients in group C, 37 patients had mSPM (51 lesions), including head and neck cancer in 14 patients (24 lesions) and gastric cancer in 12 patients (16 lesions). The SIR of mSPM was 3.61 in this study subjects. An increase in the LVL grade (A to B to C) was associated with a progressive increase in the cumulative incidence rate of mSPM other than esophagus (P = 0.017 for A vs. C, P = 0.023 for B vs. C). An increase in the LVL grade (A to B to C) was also associated with a progressive increase in the total number of mSPM other than esophagus per 100 person-years (primary events, relative risk [RR] = 1.66 and 3.24 for grades B and C, respectively, vs. A, P = 0.002 for trend; all events, RR = 1.81 and 4.66 for grades B and C, respectively, vs. A, P < 0.0001 for trend). LVL grade C was a strong predictor of mSPM other than esophagus (RR = 3.41 for A vs. C). LVL grade may be a useful predictor of the risk of mSPM other than esophagus after ER in patients with early esophageal SCC.

Katada, Chikatoshi↗

Optimal Spatial Separation of High-Order Harmonics from Infrared Driving Lasers with an Annular Beam in the Overdriven Regime

We study high-order harmonic generation (HHG) with an annularly shaped high-power, high-repetition-rate laser. In this work we investigate how the spatial separation (or divergence) of the incident laser and the generated high-order harmonics depends on the gas pressure when the laser intensity is in the overdriven regime. It is shown that, when the cone size of the incident annular beam is relatively large, the resulting harmonics are highly collimated along the propagation axis and are spatially separated from the incident beam. Under the overdriven condition, dynamic phase matching favors HHG emissions from short-trajectory electrons that are efficiently built up in the second half of the gas medium. We verify that using an annular beam is a simple and effective method for separating the intense incident infrared laser from the generated high harmonics. Such high-flux and low-divergence light pulses are expected to be powerful sources in the laboratory for ultrafast probing of electron dynamics.

47 OTHER INSTRUMENTATION↗

Prompt-fission-neutron spectra in the 239 Pu( n,f ) reaction

Prompt-fission-neutron spectra from Pu 239 ( n , f ) were measured with respect to Cf 252 spontaneous fission for incident neutron energies from 0.7 to 700 MeV at the Weapons Neutron Research facility (WNR) of the Los Alamos Neutron Science Center. A newly designed high-efficiency fission chamber was coupled to the highly segmented Chi-Nu neutron liquid scintillator array to detect neutrons emitted in fission events. The double time-of-flight technique was used to deduce the incident neutron energies from the spallation target and the outgoing-neutron energies from the fission chamber. Prompt-fission-neutron spectra (PFNS) were measured with respect to Cf 252 spontaneous fission down to 200 keV and up to about 12 MeV for all the incident neutron energies with typical total uncertainties well below 2 % up to about 7-MeV outgoing-neutron energy. The general trend of PFNS is well reproduced by JEFF3.3 and ENDF evaluations, although a better agreement is found with JEFF3.3. Discrepancies were observed for the low-energy part of the spectra, especially around the opening of the second-, third- and fourth-chance fission. Additionally, neutron average kinetic energies as a function of incident neutron energy are obtained experimentally with reported total uncertainties below 0.5 % . The measured values agree with the most recent data. The trend is fairly well reproduced by the JEFF3.3 evaluation, although it fails to reproduce the experimental values within their uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗